• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 170
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 172
  • 104
  • 64
  • 41
  • 36
  • 29
  • 28
  • 24
  • 22
  • 21
  • 20
  • 20
  • 18
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Análise dos resultados imediatos e tardios do tratamento percutâneo da coartação da aorta em adolescentes e adultos: comparação entre balões e stents / Analysis of the immediate and late results of percutaneous treatment of coarctation of the aorta in adolescents and adults: comparison between balloons and stents

Carlos Augusto Cardoso Pedra 05 July 2004 (has links)
Mais informações são necessárias para definir se o tratamento percutâneo da coartação da aorta com stents é superior à angioplastia com cateter-balão. De julho de 2000 a maio de 2003, 21 adolescentes e adultos com coartação da aorta focal e média de idade de 24 anos (DP 11 anos) foram submetidos, consecutivamente, a implante de stents (grupo 1). Os resultados foram comparados com os obtidos em um grupo histórico de 15 pacientes com média de idade de 18 anos (DP 10 anos) (p = 0,103) submetidos a angioplastia (grupo 2) nos últimos 18 anos. Após o procedimento, a redução do gradiente sistólico foi maior (99% [DP 2%] versus 87% [DP 17%]; p = 0,015), o gradiente residual foi menor (0,4 mmHg [DP 1,4 mmHg] versus 5,9 mmHg [DP 7,9 mmHg]; p = 0,019), o ganho no local da coartação foi maior (333% [DP 172%] \"versus\" 190% [DP 104%]; p = 0,007) e o diâmetro da coartação foi maior (16,9 mm [DP 2,9 mm] versus 12,9 mm [DP 3,2 mm]; p < 0,001) no grupo 1. Alterações da parede da aorta, incluindo dissecções, abaulamentos e aneurismas, foram observadas em oito pacientes do grupo 2 (53%) e em um do grupo 1 (7%) (p < 0,001). Não houve complicações maiores. Cateterismo (n = 33) ou ressonância magnética (n = 2) de controle foram realizados em seguimento mediano de um ano para o grupo 1 e um ano e meio para o grupo 2 (p = 0,005). A redução do gradiente sistólico persistiu em ambos os grupos; entretanto, gradientes tardios mais altos foram observados no grupo 2 (mediana de 0 mmHg para o grupo 1 versus 3 mmHg para o grupo 2; p = 0,014). Não houve perdas no diâmetro da coartação no grupo 1 e houve ganho tardio no grupo 2 (16,7 mm [DP 2,9 mm] versus 14,6 mm [DP 3,9 mm]; p = 0,075). No grupo 1, dois pacientes necessitaram de novo implante de stent em decorrência da formação de aneurisma ou fratura da malha do stent. No grupo 2, as anormalidades da parede aórtica não progrediram e um paciente necessitou de redilatação em decorrência da recoartação. A pressão arterial sistêmica foi semelhante em ambos os grupos durante o seguimento (sistólica: 126 mmHg [DP 12 mmHg] no grupo 1 versus 120 mmHg [DP 15 mmHg] no grupo 2; diastólica: 81 mmHg [DP 11 mmHg] no grupo 1 versus 80 mmHg [DP 10 mmHg] no grupo 2; p = 0,149 e p = 0,975, respectivamente). Apesar de os desfechos clínicos terem sido satisfatórios e similares com ambas as técnicas, o uso de stents propiciou resultados mais previsíveis e uniformes para alívio da estenose, minimizando também o risco de desenvolvimento de alterações da parede da aorta. / More information is needed to define whether stenting is superior to balloon angioplasty for coarctation of the aorta. From July/2000 to May/2003, 21 adolescents and adults with discrete coarctation underwent consecutive stent implantation at a mean age of 24 years (SD 11 years) (group 1). The results were compared to those achieved by balloon angioplasty performed in the last 18 years in a historical group of 15 patients at a mean age of 18 years (SD 10 years) (p = 0.103) (group 2). After the procedure, systolic gradient reduction was higher (99% [SD 2%] vs. 87% [SD 17%]; p = 0.015), residual gradients lower (0.4 mmHg [SD 1.4 mmHg] vs. 5.9 mmHg [SD 7.9 mmHg); p = 0.019), gain at the coarctation site higher (333% [SD 172%] vs. 190% [SD 104%]; p = 0.007) and coarctation diameter larger (16.9 mm [SD 2.9 mm] vs.12.9 mm [SD 3.2 mm]; p < 0.001) in group 1. Aortic wall abnormalities, including dissections, bulges and aneurysms, were observed in eight patients in group 2 (53%) and in one in group 1 (7%) (p < 0.001). There was no major complication. Repeat catheterization (n = 33) or magnetic resonance imaging (n = 2) was performed at a median follow-up of 1.0 year for group 1 and 1.5 year for group 2 (p = 0.005). Gradient reduction persisted in both groups, although higher late gradients were observed in group 2 (median of 0 mmHg for group 1 vs. 3 mmHg for group 2; p = 0.014). There was no late loss in the coarctation diameter in group 1 and there was a late gain in group 2 (16.7 mm [SD 2.9 mm] for group 1 vs. 14.6 mm [SD 3.9 mm] for group 2; p = 0.075). Two patients required late stenting due to aneurysm formation or stent fracture in group 1. Aortic wall abnormalities did not progress and one patient required redilation due to recoarctation in group 2. Blood pressure was similar in both groups at follow-up (systolic: 126 mmHg [SD 12 mmHg] in group 1 vs. 120 mmHg [SD 15 mmHg] in group 2; diastolic: 81 mmHg [SD 11 mmHg] in group 1 vs. 80 mmHg [SD 10 mmHg] in group 2; p = 0.149 and p = 0.975, respectively). Although satisfactory and similar clinical outcomes were observed with both techniques, the use of stents yielded more predictable and uniform results for stenosis relief, also minimizing the risk of developing aortic wall abnormalities.
172

Adesão dos profissionais de saúde aos protocolos em assistência farmacêutica - medicamentos excepcionais / Membership of health professionals in pharmaceutical care protocols - exceptional drugs

Vasconcelos, Daniela Moulin Maciel de January 2009 (has links)
Made available in DSpace on 2011-05-04T12:36:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2009 / Entre os objetivos da Política Nacional de Medicamentos constam o acesso e o financiamento dos denominados medicamentos de dispensação em caráter excepcional (MDCE). Estes, conhecidos por representarem um gasto governamental relativamente alto, se destinam ao tratamento de doenças em sua maioria, crônicas , que atingem uma pequena parcela da população. Para respaldar sua utilização promovendo adequada alocação dos recursos e o uso racional, o Ministério da Saúde publica protocolos clínicos e diretrizes terapêuticas (PCDT), cujo cumprimento é pré-requisito para o acesso dos pacientes a esses medicamentos pelo programa governamental. A adesão dos prescritores aos protocolos é fator imprescindível ao sucesso desta estratégia. O presente estudo busca verificar, mediante critérios objetivos, o grau de cumprimento pelos prescritores dos procedimentos-chave eleitos a partir do PDCT selecionado. Realizado estudo transversal descritivo com prontuário como fonte de dados e sua revisão como estratégia. Tratamento da anemia em pacientes portadores de Insuficiência Renal Crônica (IRC) com o medicamento eritropoetina humana recombinante (EPO) foi eleita como situação traçadora. Escolhidas três unidades de saúde, sendo critérios o número de pacientes acompanhados e a natureza da organização. No banco de dados da Secretaria de Estado de Saúde do Rio de Janeiro, destinado ao acompanhamento da dispensação dos MDCE identificou-se universo de 411 pacientes com CID principal registrado para autorização de dispensação N18.0 e N18.8, que retiraram o medicamento em algum momento entre janeiro de 2004 a dezembro de 2005. Elegidos procedimentos chave do fluxograma de tratamento do PCDT para a condição traçadora como critérios de verificação. Foram revisados prontuários de 202 pacientes renais crônicos que receberam o medicamento por um período de até dois anos de acompanhamento. Quanto ao grau de adesão ao PDCT, 38,1% foram classificados como adequados, 48,5% como regular, 10,4% como insuficiente e 3% como inadequado. Os critérios mais seguidos foram: critério de inclusão valor do hematócrito ou da hemoglobina, realização inicial de hemograma completo e de contagem de plaquetas e exame de monitorização desses últimos. Os menos seguidos foram: dose inicial e suspensão temporária. No geral, há uma boa adesão, porém essa pode ser melhorada. A análise de possíveis barreiras a adesão faz-se mister. / One of the National Medicines Policy goals is to guarantee the access and funding of the group of drugs called medicines of dispensation in exceptional character (MDEC). These expensive drugs are intended for the treatment of diseases - most of them, chronic - that affect a small portion of the population. In this way, they are know to represent high cost to the public service in Brazil. To support the appropriate allocation of resources and rational use, the Health Ministry develops and public the Clinical protocols and standard treatment guidelines (CPSTG) which is essential for the patient access to the governmental program. To perceive this benefits physicians adherence is necessary. The study aims to evaluate, by objective criteria, the degree of physicians’ adherence to CPSTG. A descriptive cross-sectional study was conducted, using medical records review. CPSTG for the treatment of anemia in chronic renal patients with recombinant human erythropoietin (EPO) was chose to evaluation the adherence. Three units of health were chosen to participate due to number of patients and nature of the organization. The population was picked out from the database of the Secretary of State of Health of Rio de Janeiro, which monitor the distribution of MDEC. The universe was 411 patients with principal ICD registered N18.0 and N18.8, which withdrew the drug at some time between January 2004 to December 2005. To verify the adherence to statements from CPSTG was elected key procedures from CPSTG the treatment of anemia in patients with Chronic Renal Failure (CRF) using EPO flowchart. 202 chronic renal patients medical records were reviewed who received the drug for up to two years of monitoring. The characteristics of patients in the study were similar to the patients described in the 2008 Brazilian Census of Dialysis. Among the comorbidities presented by patients, 76.24% had hypertension and 7.42% ischemic heart disease or congestive heart failure. Regarding adherence, 38.1% were classified as adequate, 48.5% regular, 10.4% insufficient and 3% as inadequate. The most followed criterias were: criterion for inclusion of the value of hematocrit or hemoglobin, achieving initial complete blood platelet count monitoring and examination of these latter. The least followed were: initial dose and temporary. It follows that a good adherence was obtained from the study, but this can be improved. It is indispensable the analysis of possible barriers to adherence.

Page generated in 0.3587 seconds