• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 74
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 76
  • 76
  • 53
  • 47
  • 26
  • 15
  • 15
  • 13
  • 13
  • 11
  • 11
  • 11
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Efeito de um infiltrante resinoso no tratamento de lesões de mancha branca: análise in vitro e in situ / Efffect of a resinous infiltrant on the tratment of white spot lesions: in vitro and in situ analysis

Maria Cristina Carvalho de Almendra Freitas 10 April 2015 (has links)
Dentre as estratégias de tratamento de lesões incipientes de cárie, no estágio de mancha branca ativa, o infiltrante resinoso tem sido empregado, preenchendo os poros do esmalte e impedindo a sua progressão. O objetivo deste trabalho foi avaliar o efeito do infiltrante de cárie (Icon®) sobre lesões cariosas artificiais produzidas por diferentes protocolos e a eficiência deste tratamento após novo desafio ácido por modelos experimentais in vitro e in situ, utilizando a microdureza de superfície (MS) e longitudinal (ML). Na fase in vitro, lesões cariosas artificiais foram produzidas em 45 espécimes de esmalte bovino (6x4mm) através de três diferentes protocolos (ciclagem DES-RE, gel MC e solução MHDP). Os espécimes foram tratados com o infiltrante e submetidos a novo desafio ácido por ciclagem DES-RE. Este delineamento resultou em 4 condições em um mesmo espécime: hígida (H), após a desmineralização (D), após o tratamento com o infiltrante (I) e após o novo desafio ácido (N). Na fase in situ, 15 voluntários usaram dispositivos palatinos contendo dois espécimes por 14 dias, induzindo a lesão por meio de gotejamento de solução de sacarose 8x/dia. Nas duas fases, a MS e ML foram avaliadas em todas as condições dos espécimes até 220&#x3BC;m. Os dados foram coletados e processados pela porcentagem da diferença com os valores iniciais da condição hígida para serem analisados estatisticamente de acordo com ANOVA (medidas repetidas) e teste de Tukey (p<0,05). No estudo in vitro e in situ todos os protocolos de desmineralização foram capazes de produzir lesões de cárie de subsuperfície. Todos os protocolos in vitro promoveram perda de dureza de superfície maior que 75%, enquanto o protocolo in situ promoveu quase 40%. Há uma redução da perda de dureza à medida que a profundidade aumenta em todos os casos, sendo as particularidades mais observadas até 50 &#x3BC;m. O infiltrante avaliado em todas as condições foi capaz de re-equilibrar parcialmente a dureza interna, entretanto sua resistência e efeito após o novo desafio ácido apresentou-se limitado. / Among the strategies for early caries lesions treatment as active white spot, the resin infiltrant has been employed filling the enamel pores and preventing their progression. The aim of this study was to evaluate the effect of caries infiltrant (Icon®) on artificial carious lesions produced by different protocols, and the efficiency of this treatment after new challenge acid by in vitro and in situ experimental models, using the surface microhardness (SH) and cross-sectional microhardness (CSH). In the in vitro phase, artificial carious lesions were performed on 45 enamel bovine specimens (6x4mm) by three different protocols (DE-RE cycling, MC gel and MHDP solution). The specimens were treated with the infiltrant and subjected to a new challenge by DE-RE cycling. This design resulted in four conditions at the same specimen: sound (S), after demineralization (D), after the treatment with infiltrant (I) and after the new acid challenge (N). In the in situ phase, 15 volunteers wore intraoral appliances containing two specimens for 14 days, inducing the lesion formation by sucrose solution dripping 8x/day. In both models, SH and CSH were evaluated in all conditions of the specimens up to 220&#x3BC;m. Data were collected and processed as percentage from the difference to each condition compared to sound stage to be statistically analyzed with ANOVA (repeated measures) and Tukey test (p <0.05). For all tested conditions, demineralization protocols were able to produce subsurface carious lesions. All in vitro protocols promoted hardness loss higher than 75% while in situ protocol promoted almost 40%. There is a reduction in the hardness loss as the depth increases, in which the main differences can be noticed up to 50&#x3BC;m. The infiltrant evaluated in all conditions was able to partially re-balance the internal hardness, however its strength and effect after the new challenge acid had been limited.
22

Análise do efeito de adição do marcador Rodamina B em propriedades mecânicas de sistemas adesivos não simplificados / Analysis of the effect of addition of Rhodamine B marker on mechanical properties of non-simplified adhesives

Machado, Camila Moreira 12 December 2014 (has links)
Este estudo in vitro avaliou o efeito da adição de rodamina B dissolvida em etanol nas concentrações de 0,02mg/mL e 0,10mg/mL, nas propriedades mecânicas dos sistemas adesivos não simplificados considerados padrão-ouro. 96 coroas de terceiros molares humanos hígidos foram seccionadas transversalmente no terço oclusal para remoção do esmalte e exposição da dentina. Os espécimes foram divididos de acordo com os sistemas adesivos Adper Scotchbond Multi-Purpose (MP) - convencional de três passos ou Clearfil SE Bond (SE) - autocondicionante de dois passos: MP-C e SE-C (MP e SE controles); MP-C1 e SE-C1 (MP e SE com rodamina B 0,02mg/mL); MP-C2 e SE-C2: (MP e SE com rodamina B 0,10mg/mL). Para o teste de RU, os espécimes (n=10) foram submetidos ao desgaste com lixas de granulação 320 e 600. A dentina foi tratada de acordo com as instruções de cada fabricante dos sistemas adesivos e restaurada com resina composta FiltekTM Z250. Após o armazenamento em saliva artificial (7dias/37oC), os espécimes foram seccionados para obtenção de palitos com 0,64 mm2 de área média e submetidos ao teste de microtração em máquina de teste universal a 0,5 mm/min, que foram analisados após 7 dias e 6 meses. O modo de fratura dos espécimes foi analisado com estereomicroscópio digital (x200) e classificado em: adesiva, coesiva em dentina, coesiva em resina e mista. Para o teste de MS, as coroas seccionadas (n=6) foram planificadas com lixa de granulação 600. A dentina foi tratada de acordo com as instruções de cada fabricante dos sistemas adesivos e os espécimes foram mantidos secos em estufa a 37oC durante 48 horas. O teste de MS foi realizado utilizando ponta Knoop (Microdurômetro Shimadzu HMV-2), a 10x e carga estática de 25gF por 10 segundos. Os resultados obtidos foram analisados por análise de variância (ANOVA-2 critérios) e teste de Bonferroni para comparações múltiplas (p<0,05). A análise de acordo com o tempo foi realizada com o teste de t-student. Os valores médios de RU e desvio padrão (MPa±dp; 7 dias / 6 meses) foram: MP-C (41,95±2,38 / 22,76±3,66); MP-C1 (28,02±5,12 / 17,93±5,70); MP-C2 (26,28±5,55 / 14,30±5,68); SE-C (46,07±1,43 / 19,07±6,75); SE-C1 (37,49±13,31 / 18,54±6,71); SE-C2 (34,16±7,71 / 17,89±4,87). No tempo de 7 dias, os fatores sistema adesivo e concentração de rodamina B foram significantes. Após 6 meses, apenas o fator concentração de rodamina B foi significante. A falha de fratura predominante em todos os grupos foi adesiva. Os valores de MS (KHN) e desvio padrão foram: MP-C (8,97±3,85); MP-C1 (7,33±0,99); MP-C2 (7,17±2,45); SE-C (4,71±4,42); SE-C1 (4,42±0,56); SE-C2 (3,27±0,30). Na comparação entre os sistemas adesivos, eles diferiram entre si na condição controle e de 0,10mg/mL. Para cada adesivo, não houve diferença entre as distintas condições de acordo com a adição de rodamina B. Em função dos resultados apresentados, a adição de rodamina B nos sistemas adesivos não simplificados MP e SE, nas concentrações de 0,02mg/mL e 0,10mg/mL, deve ser incorporada com cautela para que não influencie nas propriedades mecânicas do material. / This in vitro study evaluated the effect of addition of rhodamine B dissolved in ethanol in concentrations of 0.02mg/mL and 0.10mg/mL, the mechanical properties of non-simplified adhesive systems. 96 crowns of human third molars were transversely sectioned on the oclusal third to remove the enamel and exposure the dentin. The specimens were divided according to the adhesive systems Adper Scotchbond Multi-Purpose (MP) 3-step-etch-andrinse or Clearfil SE Bond (SE) 2-step-self-ecthing: MP-C and SE-C (MP and SE controls); MP-C1 and SE-C1 (MP and SE with 0.02mg/mL rhodamine B); MP-C2 and SE-C2: (MP and SE with 0.10mg/mL rhodamine B). For the &#x3BC;TBS test, the specimens (n=10) were ground with 320- to 600-grit silicon carbide paper. The dentin was treated according to the instructions of each manufacturer and restored with composite resin FiltekTM Z250. The specimens were stored in artificial saliva (7 days/37oC), and then sectioned to obtain sticks with an average of 0.64 mm2 area and submitted to &#x3BC;TBS test at a universal testing machine at 0.5 mm/min, which were analyzed immediately after 7 days and 6 months. The mode of fracture of the specimens was analyzed with digital stereomicroscope (x200) and classified as: adhesive, cohesive in dentine, cohesive in resin and mixed. For the SM test, the sectioned crowns (n=6) were flattened with 600-grit silicon carbide paper. The dentin was treated according to the manufacturers instructions for each adhesive system and the specimens were stored in dry condition at 37oC during 48 hours. The SM test was performed with Knoop indenter (Shimadzu HMV-2 hardness tester), at 10x and 25gF of load for 10 seconds. The results were analyzed by two-way analysis of variance tests and the Bonferroni test for multiple comparisons (p<0.05). The analysis regarding time was checked with t-student test. The mean &#x3BC;TBS and standard deviation (MPa±dp; 7 days / 6 months) were: MP-C (41.95±2.38 / 22.76±3.66); MP-C1 (28.02±5.12 / 17.93±5.70); MP-C2 (26.28±5.55 / 14.30±5.68); SE-C (46.07±1.43 / 19.07±6.75); SE-C1 (37.49±13.31 / 18.54±6.71); SE-C2 (34.16±7.71 / 17.89±4.87). In the immediate time, the adhesive system and rhodamine B concentration factors were significant. After 6 months, only the rhodamine B concentration was a significant factor. The predominant failure in all groups was adhesive. The values of SM and standard deviation were: MP-C (8.97±3.85); MP-C1 (7.33±0.99); MP-C2 (7.17±2.45); SE-C (4.71±4.42); SE-C1 (4.42±0.56); SE-C2 (3.27±0.30). In the comparison between the adhesive systems, they were significantly different for the conditions control and 0.10mg/mL. For each adhesive systems, there was no difference between the different conditions according to the addition of rhodamine B. Regarding the shown results, addition of rodhamine B in non-simplified adhesives MP and SE, in the concentrations of 0.02mg/mL e 0.10mg/mL must be carefully added to avoid implications to the mechanical properties of the materials.
23

Estudo da resistência ao desgaste de um ferro fundido branco de alto crómio

Afonso, André Filipe Martins January 2012 (has links)
Estágio realizado na Cruz Martins & Wahl, Lda. - e orientado pelo Eng. Carlos Dias / Tese de mestrado integrado. Engenharia Metalúrgica e de Materiais. Faculdade de Engenharia. Universidade do Porto. 2012
24

Efeito do envelhecimento acelerado sobre a microdureza superficial, rugosidade e opacidade de resinas acrílicas incolores termopolimerizáveis e calotas oculares empregadas em prótese ocular, em função da espessura /

Fernandes, Aline Úrsula Rocha. January 2007 (has links)
Orientador: Marcelo Coelho Goiato / Banca: Humberto Gennari Filho / Banca: Stefan Fiuza de Carvalho Dekon / Banca: Mauro Antonio de Arruda Nobilo / Banca: Nuno Filipe D'Almeida / Resumo: As próteses oculares são responsáveis pelo restabelecimento da estética, harmonia facial e auto-estima do paciente anoftálmico. Confeccionados em resina acrílica, os olhos artificiais devem ser estéticos, perfeitamente polidos e resistentes a riscos, características que, quando não satisfeitas, podem gerar transtornos psicológicos, possíveis infecções ou inflamações originárias de substâncias e organismos depositados nas irregularidades superficiais da prótese. O propósito do estudo foi avaliar a microdureza e rugosidade superficiais e opacidade de calotas incolores próprias para prótese ocular e de três marcas de resina acrílica incolor termopolimerizável por banho de água quente de curta e média duração e duas por energia de microondas, em função do envelhecimento acelerado (1008 horas) e espessura (1 e 3,5 mm). Para o estudo, foram obtidas 120 amostras, distribuídas em 12 grupos (n= 10). A análise foi realizada por meio de microdurômetro (Shimadzu Corp., Kyoto, Japão), rugosímetro (TONKA Sul Americana Ltda., SP, Brasil) e espectrofotômetro de reflexão (Shimadzu Corp., Kyoto, Japão). Os valores obtidos antes e após envelhecimento acelerado foram analisados estatisticamente pela Análise de Variância de três fatores e pelo teste de Tukey a 1% de significância. Para o teste de microdureza, as calotas oculares e a resina QC 20 apresentaram, respectivamente, os maiores e menores valores de microdureza superficial, independente da variável avaliada; a espessura não influenciou a propriedade estudada e as amostras apresentaram valores médios de microdureza superficial maiores após o envelhecimento acelerado. / Abstract: Artificial eyes are responsible for reestablishing the facial esthetics, harmony and self esteem of the anophthalmic patient. Made of acrylic resin, artificial eyes must be esthetic, perfectly polished and scratchresistant characteristics which, when not satisfied, may cause psychological disturbances, possible infections or inflammations originating from substances and organisms deposited on the surface irregularities of the prosthesis. The aim of this study was to assess the microhardness, surface roughness and opacity of colorless ocular button for the purpose of use in artificial eyes, and three brands of colorless acrylic resin heat-polymerizable by hot water bath of short and medium duration and two by microwave energy, as a function of accelerated aging (1008 hours) and thickness (1 and 3.5 mm). For this study, 120 samples were obtained, distributed into 12 groups (n=10). Analysis was performed by means of microhardness meter (Shimadzu Corp., Kyoto, Japan), rugosity meter (TONKA Sul Americana Ltda., SP, Brazil) and reflection spectrophotometer (Shimadzu Corp., Kyoto, Japan). The values obtained before and after accelerated aging were statistically analyzed by Analysis of Variance for 3 factors and the Tukey test at 1% significance. For the microhardness test, the ocular buttons and QC 20 resin respectively presented the highest and lowest surface microhardness values, irrespective of the variable assessed; the thickness had no influence on the studied property, and the samples presented higher mean surface microhardness values after accelerated aging. For the roughness test, there was no statistically significant difference with regard to accelerated aging; the resin Vipi Cril, at the thickness of 3.5 mm and ocular button at the thickness of 1 mm presented the lowest roughness value. / Doutor
25

Influência da composição de resinas compostas no grau de conversão e degradação hidrolítica

Jassé, Fernanda Ferreira [UNESP] 03 August 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:35Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-08-03Bitstream added on 2014-06-13T19:09:28Z : No. of bitstreams: 1 jasse_ff_me_arafo.pdf: 3143943 bytes, checksum: db74ccbc66112c4a240ca5402754512c (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Numerosos tipos e marcas comerciais de resinas compostas são constantemente introduzidos no mercado odontológico, em função de modificações na composição, tipo, formato e quantidade das partículas inorgânicas, assim como na porção orgânica. Sempre, com a finalidade de proporcionar propriedades mecânicas e estéticas superiores aos materiais, aumentando dessa forma sua longevidade. Assim, o propósito neste estudo foi avaliar o grau de conversão (GC) pelo método FT-IR e a degradação hidrolítica por meio do teste de dureza Vickers (dV), de duas resinas compostas (uma nanoparticulada e uma micro-híbrida). Para isso, oito espécimes (4 mm de diâmetro x 2 mm de espessura, ISO 4049) de cada material foram confeccionados para cada teste. As resinas compostas foram inseridas em única porção na matriz metálica e fotoativadas com aparelho LED (Celalux, Voco®, 776 mW/cm²), por 40 segundos. Dezesseis leituras de dV (8 no topo e 8 na base) foram realizadas para cada espécime em durômetro digital MMT-3 (Buehler Lake Bluff, Illinois USA), utilizando carga de 50 gf aplicada durante 30 segundos, em intervalos de tempo prédeterminados: imediatamente após fotoativação (controle), 24, 48, 72 horas, 7, 14, 21, 30 dias e 6 meses. Logo após a fotoativação foi feita a medida da dureza inicial e os espécimes foram então imersos em saliva artificial a 37°C. Para o GC (%), os espécimes foram triturados, prensados com KBr e analisados em espectrofotômetro FT-IR (Nexus-470). Os resultados foram submetidos à análise estatística e permitiram concluir que: não foi observada diferença entre as resinas quanto ao grau de conversão; a proporção entre as medidas de dureza de topo e base foi semelhante para os dois materiais, tendo sido mantida ao longo de todo o tempo experimental; a resina Z-250 apresentou os maiores valores de dureza tanto na superfície de topo quanto na de base... / Numerous types and brands of composite resins are constantly introduced into the dental market, due to changes in the composition, type, shape and quantity of inorganic particles as well as the organic portion. Always with the aim of providing superior mechanical and aesthetic properties to materials, thereby increasing their longevity. Thus, the purpose of this study was to evaluate the degree of conversion (DC) and hydrolytic degradation through the Vickers hardness test (hV) of two composites (a nanofilled and a microhybrid). For this, eight specimens (4 mm diameter x 2 mm thick, ISO 4049) of each material were prepared for each test. The composites were inserted into single increment in the metallic matrix and photoactivated with a LED unit (Celalux, Voco ®, 776 mW / cm ²) for 40 seconds. Sixteen hV readings (8 on each top and bottom surfaces) were performed for each specimen in MMT-3 digital hardness tester (Buehler Lake Bluff, Illinois USA), using load of 50 gf applied for 30 seconds, at predetermined intervals: immediately after polymerization (control), 24, 48, 72 hours, 7, 14, 21, 30 days and 6 months. After curing, initial hardness measurements were performed and the specimens were immersed in artificial saliva at 37 °C. For the DC (%), the specimens were ground, pressed with KBr and analyzed by FT-IR spectrophotometer (Nexus-470). The results were subjected to statistical analysis and concluded that: there was no difference between the resins for degree of conversion; the ratio between top and bottom hardness values was similar for both materials and was maintained throughout the experimental period; the composite resin Z-250 showed the highest hardness values in both the top surface as the bottom throughout the evaluation period. The materials tested showed no evidence of hydrolytic degradation in a significant way, in a six-month storage-time in artificial saliva
26

Análise da qualidade de polimerização, por meio de testes de microdureza, de um cimento resinoso utilizado na cimentação de coroas totais em preparos com diferentes substratos / Analysis of quality of polymerization of a resin cement used to cement ceramic crowns in differents preparation substrates through microhardness tests

Luana Menezes de Mendonça 27 May 2011 (has links)
O objetivo deste estudo foi avaliar a microdureza do cimento resinoso Variolink II ( Ivoclar Vivadent, Schaan, Liechtenstein) empregado na cimentação de coroas totais de cerâmica (IPS e.max Press, Ivoclar Vivadent, Schaan, Liechtenstein) em preparos com 3 substratos (dentina, metal e resina composta). Foram utilizados 30 molares distribuídos em 3 grupos de acordo com o tipo de substrato. No grupo com substrato em dentina (D), as coroas foram cimentadas em dentes preparados em dentina. Nos grupos com substrato em metal (M) e resina (R), as coroas foram seccionadas no nível da junção cemento-esmalte e restauradas com núcleos metálicos e de preenchimento em resina composta, respectivamente. Cada um dos grupos foi subdividido em subgrupos para avaliação após 7 dias e 3 meses de armazenamento em água deionizada. Os espécimes foram seccionados no centro das coroas, no sentido vestíbulo-lingual e as superfícies foram polidas para a realização dos testes de microdureza ao longo da linha de cimento. Os valores de microdureza foram obtidos nos terços cervical, médio, oclusal das faces vestibular e lingual e na face oclusal. Os resultados foram submetidos a uma análise estatística prévia ANOVA a 3 critérios (substratos/ armazenamento/ terços e face oclusal), a qual não mostrou diferenças significativas entre os terços e face oclusal nos 2 períodos de armazenamento. Em seguida foi realizada a ANOVA a 2 critérios (substrato e armazenamento) e o teste de Tukey que mostraram os resultados do substrato em resina estatisticamente inferiores aos de dentina e metal, após o período de armazenamento de 7 dias. Conclui-se que a microdureza do cimento resinoso não variou nos diferentes terços e face e que a influência do substrato em resina no cimento foi tempo-dependente. / The aim of this study was to evaluate the microhardness of resin cement Variolink II (Ivoclar Vivadent, Schaan, Liechtenstein) used to cement full ceramic crowns (IPS e.max Press, Ivoclar Vivadent, Schaan, Liechtenstein) in three preparations substrates (dentin, metal and composite resin). Thirty molars were divided into three groups, according to the type of the substrate. In the dentin substrate group (D), the crowns were prepared in dentin; the metal (M) and resin (R) substrates groups, the crowns were sectioned at cement enamel junction level and restored with metal cast post and composite resin filler, respectively. Each group was subdivided into subgroups to evaluation after 7 days and 3 months of storage in deionized water. After cementing the specimens were sectioned buccolingually at the center of the crowns, and the surfaces were polished to microhardness test along the cement line. The microhardness values were obtained in the cervical, medium and occlusion thirds of the buccal and lingual surfaces and in the occlusal surface. The results were submitted to a three-way ANOVA (substrates / storage / thirds and occlusal surface) to a prior statistical analysis and did not show significant differences between the occlusal surface and thirds in the two storage periods. Then two-way ANOVA (substrate and storage) and the Tukey test were performed. The results in the resin group were statistically lower than those of dentin and metal, after 7 days of storage. Therefore, the microhardness of resin cement did not change in the different thirds and face and that the influence of the resin substrate was time-dependent.
27

Avaliação de uma nova composição de agente clareador sobre a microdureza do esmalte: associação do trimetafosfato de sódio e fluoreto de sódio ao peróxido de hidrogênio a 10%

Santos, Ana Laura Esteves dos [UNESP] 31 March 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-31Bitstream added on 2015-03-03T12:07:01Z : No. of bitstreams: 1 000795291.pdf: 1773705 bytes, checksum: 0619683643bd7f91393f94db61d67323 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivos: avaliar a ação do trimetafosfato de sódio (TMP)+fluoreto de sódio (NaF) em duas concentrações 3%TMP+0,1%NaF e 0,3%TMP+0,05%NaF, adicionados ao peróxido de hidrogênio (PH) 10%, em inibir a desmineralização do esmalte em contato com dentifrício fluoretado (DF) ou não (DP). Métodos: Blocos de esmalte bovino (4.0 x 4.0 mm) foram obtidos, planificados e polidos para leitura da microdureza superficial Knoop (SH) inicial (25g/5seg). 72 blocos selecionados (320-380KHN) foram divididos aleatoriamente em 6 grupos (n=12), de acordo com o gel clareador e o dentifrício: PH+DF; PH+3TMP+0,1NaF+DF; PH+0,3TMP+0,05NaF+DF; PH+DP; PH+3TMP+0,1NaF+DP; PH+0,3TMP+0,05NaF+DP. O clareamento foi realizado por 30min/dia, seguido da imersão das amostras em dentifrício (1min) durante 14 dias e entre as sessões, mantidos em saliva artificial à 37oC. Em seguida, foi realizada a leitura da SH final e os blocos foram seccionados ao meio para análise da dureza em profundidade (?KHN) (5g/5seg). O cálculo da perda de dureza foi realizado a partir dos valores de SH/?KHN e submetidos à análise estatística. Imagens de Microscopia de Luz Polarizada (MLP) foram obtidas do corte longitudinal das amostras. Resultados: O PH+3TMP+0,1NaF+DF demonstrou os melhores resultados, seguido pelo PH+0,3TMP+0,05NaF+DF. O PH+DF e PH+DP apresentaram os menores valores de SH/?KHN. No entanto, a ?KHN do PH+DF foi estatisticamente superior ao do PH+DP. As imagens qualitativas de MLP mostraram nitidamente uma desmineralização subsuperficial para os grupos PH+DF e PH+DP. Significância: A adição do TMP+NaF ao gel de PH foi eficaz na diminuição da perda de dureza. A aplicação do SF foi benéfica à ação do TMP+NaF no gel clareador. / Objectives: To evaluate the effects of sodium trimetaphosphate (TMP) + sodium fluoride (NaF) in two concentrations 3%TMP+0.1%NaF and 0.3%TMP+0.05%NaF, added to hydrogen peroxide (HP) 10% by inhibiting demineralization of enamel in contact with fluoridated dentifrice (FD) or not (PD). Methods: Bovine enamel blocks (4.0 x 4.0 mm) were flat and polished in order to perform the initial Knoop surface microhardness (SH) analysis (25g/5s). Seventy two selected blocks (320-380KHN) were randomly assigned into 6 groups (n=12), according to the bleaching gel and slurry: HP+FD; HP+3TMP+0.1NaF+FD; HP+0.3TMP+0.05NaF+FD; HP+PD; HP+3TMP+0.1NaF+PD; HP+0.3TMP+0.05NaF+PD. Bleaching was carried out 30min/day, followed by immersing the samples in dentifrice (1min) for 14 days and between sessions, stored in artificial saliva at 37oC. Then, the final SH reading was taken and the blocks were cut in halves to analyze cross-sectional hardness (?KHN) (5g/5s). The calculation of the loss of microhardness (%SH) was carried out from the values of SH/?KHN and subjected to statistical analysis. Images from Polarized Light Microscopy (PLM) were obtained from the longitudinal section of the samples. Results: HP+3TMP+0.1NaF+FD showed the best results, followed by HP+0.3TMP+0.05NaF+FD. HP+FD and HP+PD showed the lowest values of %SH/?KHN. However, ?KHN of HP+FD was statistically higher than HP+PD. Qualitative PLM images clearly showed subsurface demineralization for groups HP+FD and HP+PD. Conclusion: The addition of TMP+NaF to the gel of HP was effective in reducing the loss of hardness. Applying FD was beneficial to the action of TMP+NaF of the bleaching gel.
28

Efeito da composição de pinos intrarradiculares na dureza de diferentes cimentos resinosos / Marcos Kenzo Takahashi ; orientadora, Evelise M. Souza

Takahashi, Marcos Kenzo January 2012 (has links)
Tese (doutorado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2012 / Inclui bibliografias / Introdução: O objetivo deste estudo foi determinar a dureza de cimentos resinosos de ativação química e dual para a cimentação de diferentes pinos em três profundidades do canal radicular. Métodos: Um canal radicular simulado foi confeccionado em um bloco / Objectives: The aim of the present study was to assess the hardness of selfand dual-cured resin cements used for the Iuting of different types of posts at different root canal depths. Methods: A simulated root canal was constructed in a Tefion® block. Tra
29

Efeitos do plasma de baixa temperatura sobre os substratos esmalte e dentina / Effecs of low temperature plasma on enamel and dentin substrates

Alves, Roberto Haniery Ponte 22 July 2015 (has links)
ALVES, R. H. P. Efeitos do plasma de baixa temperatura sobre os substratos esmalte e dentina. 2015. 44 f. Dissertação (Mestrado em Odontologia) - Faculdade de Farmácia, Odontologia e Enfermagem, Universidade Federal do Ceará, Fortaleza, 2015. / Submitted by Erika Fernandes (erikaleitefernandes@gmail.com) on 2016-05-24T12:42:59Z No. of bitstreams: 1 2015_dis_rhpalves.pdf: 3211354 bytes, checksum: a18ac67c873e9bb8b5db147d33558b04 (MD5) / Approved for entry into archive by Erika Fernandes (erikaleitefernandes@gmail.com) on 2016-05-24T12:43:14Z (GMT) No. of bitstreams: 1 2015_dis_rhpalves.pdf: 3211354 bytes, checksum: a18ac67c873e9bb8b5db147d33558b04 (MD5) / Made available in DSpace on 2016-05-24T12:43:14Z (GMT). No. of bitstreams: 1 2015_dis_rhpalves.pdf: 3211354 bytes, checksum: a18ac67c873e9bb8b5db147d33558b04 (MD5) Previous issue date: 2015-07-22 / Low-temperature plasma (LTP) is a promising technology with the potential benefit of destroying the matrix of the oral biofilm and also produce antimicrobial effect on the bacterial cell. However, the effect of LTP on dental structures is not clear. The objective of this study was to evaluate the effect of LTP on enamel and dentin substrates. Therefore, we analyzed Knoop microhardness to calculate the percentage of surface hardness (SH), changes in contact angles (CA), the surface topography by Scanning Electron Microscopy (SEM) and also the chemical composition by Raman spectrometry (RS). Initially, 4x4x2 mm enamel and dentin blocks were prepared from bovine incisors. All blocks were polished and divided into three groups (n = 6); argon plasma, argon flow rate and control. The SH was assessed before and after each treatment, performing five penetrations in each specimen (50g / 25g and 5s enamel / dentin 5s). Contact angles changes were performed by dispersing water drop on the treated surfaces and observing the contact angle obtained after 1 min and 1 hour. For that, high-resolution digital photos and the Image J program was used. Physical changes in the structure of enamel and dentin submitted to LTP were observed from the SEM. Additionally, the relative proportion of the organic and mineral content of the enamel and dentin after treatment were analyzed by RS. Data were evaluated by analysis of variance (ANOVA) - 2-way (treatment and time) and Tukey test (α <0.05). For the SH the results showed no significant difference in the enamel (p=0.087), however, the SH of dentin decreased after treatment with argon plasma (p=0.005). The results indicated that water contact angle values in enamel decreased after 1min of the application of argon plasma (p<0.05). In the dentin the contact angle decreased after 1 and 60 min of the application of argon plasma (p<0.05). The RS results showed than argon plasma and argon gas presented lower organic matrix bands, similar results were observated for both enamel and dentin. The SEM showed that in addition to removing the external smear layer to the dentinal tubules, treatment with LTP promoted cracks in the enamel and the dentin surfaces. In conclusion, the use of argon plasma decreased the superficial hardness in dentin and, potentially increased the wetting in booth substract. Superficial morphological change and decreased of the organic matrix were observed in booth estructures after treatment with argon plasma and argon flow rate. / O plasma de baixa temperatura (PBT) tem tido seu uso investigado na destruição dos biofilmes orais, no entanto, seu efeito sobre os substratos dentários ainda não está completamente esclarecido. O objetivo deste trabalho foi avaliar o efeito do PBT na dureza superficial, no ângulo de contato, na morfologia das superfícies e composição química do esmalte e dentina bovinos. Para tanto, foram analisados a dureza de superfície Knoop (DS), as alterações nos ângulos de contato (AC), a morfologia de superfície por Microscopia Eletrônica de Varredura (MEV) e sua composição química através da Espectofotometria Raman (ER). Inicialmente, foram confeccionados blocos de esmalte e dentina com dimensões de 4x4x2 mm preparados a partir de dentes bovinos. Todos os blocos foram polidos e dividos em três grupos (n=6): Plasma de Argônio, Gás de Argônio e Controle. A DS foi avaliada antes e depois de cada tratamento, realizando-se cinco penetrações em cada espécime (50g/5s para esmalte e 25g/5s para dentina). A determinação do AC foi realizada dispersando uma gota de água sobre a superfície tratada e observando o ângulo de contato obtido em 1 min e 1 hora, utilizando fotografias digitais de alta resolução e o programa Image J. As alterações físicas na morfologia do esmalte e dentina submetidos ao PBT foram observadas a partir da MEV. Adicionalmente, a proporção relativa do conteúdo orgânico e mineral do esmalte e dentina após os tratamentos foram analisados por ER. Os dados foram avaliados por análise de variância (ANOVA) – 1 via para DS e 2 vias (tratamento e tempo) para AC, após Tukey teste (α < 0,05). Os resultados da DS demostraram não haver diferença significativa no esmalte (p = 0,087) após os tratamentos. No entanto, a MS da dentina diminuiu após o tratamento de plasma de argônio (p = 0,005). Os resultados indicaram que os valores de ângulo de contato da água diminuíram após 1 minuto da aplicação de plasma de argônio no esmalte (p < 0,05) e após 1 minuto e 60 minutos da aplicação de plasma de argônio na dentina (p < 0,05). Os resultados da ER demonstraram que os tratamentos com o plasma de argônio e gás de argônio apresentaram menores intensidades nas bandas da matriz orgânica para o esmalte e para a dentina. Em adição, a MEV demonstrou que, além de remover a smear layer externa aos túbulos dentinários, o tratamento com PBT promoveu rachaduras na superfície do esmalte e da dentina. Em conclusão, o PBT diminuiu a dureza superficial da dentina e melhorou potencialmente o molhamento da superfície do esmalte e dentina. Alterações morfológicas superficiais e diminuição da matrix orgânica foram observadas para ambas as estruturas dentais, depois dos tratamentos com plasma de argônio e gás de argônio.
30

Influência de soluções fluoretadas na estabilidade de cor, rugosidade e dureza superficial de resinas compostas em função do tempo

Oliveira, Ana Luísa Botta Martins de [UNESP] 27 July 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-07-27Bitstream added on 2014-06-13T20:04:53Z : No. of bitstreams: 1 oliveira_albm_dr_arafo.pdf: 1363942 bytes, checksum: 31b5ccd566c55e1abf5a60c112fc13be (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a influência de soluções fluoretadas sobre a estabilidade de cor, a rugosidade e a dureza superficiais de diferentes resinas compostas, em curto e em longo prazo. Para isso, foram realizadas pesquisas científicas, apresentadas em três capítulos. Setenta e cinco espécimes de 10 mm de diâmetro e 2 mm de espessura foram confeccionados e polidos com discos de óxido de alumínio (Super-Snap®, Shofu Dental Corp. Kyoto, Japão) em ordem decrescente de granulação. Os grupos experimentais foram divididos de acordo com o tipo de resina composta (nanoparticulada - Filtek Z350 XT, microhíbrida - Filtek Z250 e microparticulada - Durafill VS) e diferentes meios de imersão (saliva artificial, solução de fluoreto de sódio a 0,05%- manipulado, Fluordent Reach, Oral B, Fluorgard). Os espécimes permaneceram imersos em saliva artificial por 24 horas e foram submetidos à análise da cor, rugosidade e dureza iniciais. A partir disso, foram imersos nas diferentes soluções por 1 minuto ao dia durante 60 dias. Nos intervalos entre as imersões foram mantidos em saliva artificial a 370C  1 0C. Após esse período, foram submetidos às novas avaliações de cor, rugosidade e dureza superficiais. Em sequência, foram realizados os procedimentos de envelhecimento artificial utilizando-se 20.000 ciclos de termociclagem, 1.200.000 ciclos de simulação de forças mastigatórias e imersão contínua nas soluções por 1825 minutos. Após estes processos, foram realizadas leituras finais para todas as propriedades avaliadas. Os dados obtidos, nos diferentes tempos, foram avaliados estatisticamente pela Análise de Variância. Para a estabilidade de cor, utilizou-se o teste de Tukey e para a rugosidade e a dureza superficiais, os testes de Tukey e de Sidak... / The aim of this study was to evaluate the influence of fluoride solutions on color stability, surface roughness and hardness of different composite resins, in short and long term. Seventy-five specimens of 10mm diameter and 2mm thickness were made with composite resins and polished with aluminum oxide discs (Super-Snap®, Shofu Dental Corp. Kyoto, Japan) in a decreasing order of granulation. Experimental groups were divided according to (1) composite resin (nanofilled- Filtek Z350 XT, mycrohybrid Filtek Z250 and microfilled - Durafill VS) and (2) different immersion media (artificial saliva, a manipulated 0.05% sodium fluoride solution, Fluordent Reach, Oral B, Fluorgard). Specimens were kept in artificial saliva for 24 hours and submitted to color, roughness and hardness tests. From this period, specimens were immersed in the different solutions for 1 minute per day, during 60 days. In periods between immersions, specimens were kept in artificial saliva at 370C  10C. After that, the specimens were submitted to color, roughness and hardness analysis again. Then the artificial aging was carried out using 20,000 thermal cycles, 1,200,000 mechanical loading cycles and continuous immersion in the solutions for 1825 minutes. After the artificial aging, specimens were submitted to color stability, roughness and hardness tests. The obtained data for different periods were submitted to ANOVA. The color change data were evaluated by Tukey test. Surface roughness and hardness data were submitted to Tukey and Sidak tests, both at 5% significance. The highest color change and surface roughness were observed with the microfilled composite resin, followed by the nanofilled and microhybrid resin. Besides that, the lowest hardness also was obtained with the microfilled resin. The artificial aging promoted an increase of roughness and... (Complete abstract click electronic access below)

Page generated in 0.0584 seconds