• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 74
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 76
  • 76
  • 53
  • 47
  • 26
  • 15
  • 15
  • 13
  • 13
  • 11
  • 11
  • 11
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Propriedades físicas e mecânicas de um cimento de ionômero de vidro modificado por nanopartículas de hidroxiapatita ou por vidros bioativos. Tempo de armazenamento e escovação. /

Martins, Rafael Amorim. January 2018 (has links)
Orientador: Angela Cristina Cilense Zuanon / Resumo: O cimento de ionômero de vidro (CIV) apresenta características favoráveis como ação antimicrobiana e capacidade de remineralização. A fim de potencializar essas propriedades, sua associação com outros materiais como as nanopartículas (NP) e os vidros bioativos (VB) é estudada e muita atenção deve ser voltada às possíveis alterações que podem ocorrer em suas propriedades físicas, mecânicas e químicas. O objetivo deste estudo foi avaliar propriedades físicas e mecânicas do CIV associado a NP de hidroxiapatita (HPa) a 5% e ao VB 45S5 a 10%, antes e após teste de escovação, em diferentes tempos de armazenamento. Foram avaliadas rugosidade superficial com auxílio de rugosímetro, dureza Vickers por meio de microdurômetro, e variação de massa do material medida por pesagens em balança analítica, além da análise qualitativa de sua superfície, por meio de perfilômetro, nos tempos de 1, 7, 15, 30 e 60 dias, antes e após o teste de escovação. Os dados obtidos foram analisados estatisticamente quanto à normalidade e a homogeneidade. A distribuição foi não normal e os testes não-paramétricos de Wilcoxon, e de Kruskal Wallis seguido pelo de Dunn foram realizados, todos com um nível de significância de 5%. Pode-se observar maiores valores para a perda de massa no primeiro dia de experimento para todos os grupos. A rugosidade superficial foi menor nos grupos Controle e NP aos 30 dias de experimento após o ensaio de escovação. A análise qualitativa por meio do perfil dos materiais confirma a ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The glass ionomer cement (GIC) has favorable characteristics such as antimicrobial action and remineralization capacity. In order to potentiate these properties, its association with other materials such as nanoparticles (NP) and bioactive glasses (BAG) is studied, and a great deal of attention must be given to the possible changes that may occur in the physical, mechanical and chemical properties. The objective of this study was to evaluate the physical and mechanical properties of GIC associated with 5% of hydroxyapatite NP (NPHPa) and of 10% BAG 45S5 before and after brushing test at different storage times. The surface roughness was evaluated using a rugosimeter, Vickers hardness by microdurometer, and mass variation of the material measured by analytical weighing, as well as the qualitative analysis of its surface by means of a profilometer at the times of 1, 7, 15, 30 and 60 days, before and after the brushing test. The data obtained were statistically analyzed for normality and homogeneity. The distribution was non-normal and the non-parametric Wilcoxon and Kruskal Wallis followed by Dunn's tests were performed, all with a significance level of 5%. It is possible to observe higher values for the loss of mass in the first day of experiment for all the groups. The surface roughness was lower in the control and NP groups at 30 days of experiment after the brushing test. The qualitative analysis through the profile of the materials confirms these findings. Larger values fo... (Complete abstract click electronic access below) / Mestre
42

Influência do preaquecimento nas propriedades físicas de agentes cimentantes fotoativados através de diferentes espessuras de cerâmica = Influence of pre-heating on the physical properties of luting agents photoactivated through different ceramic thicknesses / Influence of pre-heating on the physical properties of luting agents photoactivated through different ceramic thicknesses

Lima, Michele de Oliveira, 1991 28 April 2015 (has links)
Orientador: Flávio Henrique Baggio Aguiar / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-27T16:00:43Z (GMT). No. of bitstreams: 1 Lima_MicheledeOliveira_M.pdf: 1194610 bytes, checksum: 09e2b8319999015738ccee35c170ebb8 (MD5) Previous issue date: 2015 / Resumo: O propósito deste estudo "in vitro" foi avaliar a influência do preaquecimento e ativação de agentes de fixação através de blocos cerâmicos sobre suas propriedades físicas. Para tanto, os agentes cimentantes RelyX Arc (RXA; 3M/ESPE), RelyX Ultimate (RXU; 3M/ESPE), RelyX Veneer (RXV; 3M/ESPE) e Filtek Z350 Flow (FLK; 3M/ESPE) foram manipulados com diferentes temperaturas (23ºC ou 54ºC), inseridos em matrizes de silicone específicas (cilíndricas: 5x0,5mm ou ampulheta: 0,5mm de espessura, 8mm de comprimento, 4mm de largura e 1,5mm de constrição, de acordo com a metodologia dos testes realizados) e fotoativados sob discos cerâmicos de dissilicato de lítio (IPS e.max; Ivoclar Vivadent, Barueri, SP, Brasil), cor A2, nas espessuras de 0,75mm ou 1,5mm.?A fotoativação foi realizada posicionando a extremidade do aparelho fotoativador sobre o disco cerâmico, para tal foi utilizado o LED Bluephase 16i (Vivadent, B?rs, Austria), com irradiância de 1519 mW/cm², por 40 segundos. Foram confeccionadas 128 amostras cilindricas (n=8) e realizados os testes de grau de conversão (GC) por meio da espectroscopia FT-IR. Estes mesmos espécimes foram levados ao microdurômetro para a mensuração da dureza Knoop (DK) na superfície de topo e logo após, foram imersos em solução de álcool absoluto por 24 h, e então foi realizada uma nova leitura de DK para a obtenção do percentual de redução de dureza e mensuração indireta da densidade de ligações cruzadas (DLC) dos materiais. Foram confeccionadas novas amostras em formato de ampulheta (n=8) que foram utilizadas para o teste de resistência coesiva à tração (RCT), realizado em máquina de ensaio universal. Para os testes de sorção de água (SA) e solubilidade (S) dos agentes de fixação, foram necessários novos espécimes cilíndricos (n=8) que foram pesados em balança analítica até obtenção de massa constante. Os dados foram analisados utilizando-se ANOVA três fatores e teste de tukey (?=0,05). Com relação às espessuras de cerâmica testadas, a menor espessura de cerâmica proporcionou maiores valores de DK (p=0.027). A menor temperatura (23°C) proporcionou maiores valores de SA (p=0.0229) e S (p=0.0257). Também houve diferença estatística para o fator cimento, sendo que para GC, RXA apresentou os maiores valores, seguido dos agentes cimentantes RXV, RXU e FLK. Para o teste de DK e DLC, RXU apresentou os maiores valores, seguido de RXA, RXV e FLK. Para o teste de RCT, RXA apresentou os maiores valores, seguido por RXV, RXU e FLK. Para SA e S, RXV apresentou os maiores valores, seguido por RXA, RXU e FLK. Pode-se concluir que o preaquecimento diminuiu nos resultados de sorção de água e solubilidade; a maior espessura de cerâmica diminuiu apenas a microdureza superficial, e que as propriedades físicas dos materiais são dependentes da composição dos mesmos / Abstract: The purpose of this "in vitro" study was to evaluate the influence of preheating on the physical properties of a luting agent photoactivated through ceramic discs. The cements: RelyX Arc (RXA, 3M / ESPE), RelyX Ultimate (RXU; 3M / ESPE), RelyX Veneer (RXV; 3M / ESPE), and Filtek Z350 Flow (FLK; 3M / ESPE) were manipulated using different temperatures (23°C or 54°C), inserted in specific silicone matrices (cylindrical: 5x0.5mm or hourglass: thickness 0.5 mm, 8 mm in length, 4mm wide and a 1.5mm constriction, according to the methodology of testing) and photoactived under lithium disilicate ceramic discs (IPS e.max, Ivoclar Vivadent, Barueri, SP, Brazil) color A2, in thicknesses of 0.75 mm or 1.5 mm. Photoactivation was carried out by positioning the end of the curing unit on the ceramic disk. A Bluephase 16i (Vivadent, B?rs, Austria), with an irradiance of 1519 mW / cm2, was used for 40 seconds to cure the specimens. One hundred twenty-eight cylindrical samples were prepared (n=8) and the degree of conversion tests (DC) were performed using FT-IR spectroscopy. The samples were taken to a Knoop hardness tester (KHN) for microhardness testing on the top surface. After the initial testing, the specimens were dipped in absolute ethanol solution for 24 h, and then a new KHN reading was performed to obtain the hardness reduction percentage and the crosslink density (CLD) indirect measurement of the material. New samples were prepared with an hourglass shape (n=8) and were used for the ultimate tensile strength (UTS) testing, performed in a universal testing machine. For the water sorption test (WS) and solubility (S) of the luting agents, new cylindrical specimens (n=8) were required which were weighed on an analytical balance until a constant mass was obtained. The data was analyzed using three-way ANOVA and Tukey¿s test (?=0.05). Regarding the tested ceramic thicknesses, the thinnest ceramic gave higher values of KHN (p=0.027). The lowest temperature (23°C) gave higher S (p=0.0257) and WS (p=0.0229) values. There was also a statistically significant difference for cement factor, where RXA showed the highest values for DC, followed by RXV, RXU and FLK. For the KHN and CLD tests, RXU showed the highest values, followed by RXA, RXV and FLK. For the UTS test, RXA showed the highest values, followed by RXV, RXU and FLK. For WS and S, RXV showed the highest values, followed by RXA, RXU and FLK. It can be concluded that pre-heating decreased the results of water sorption and solubility; the biggest ceramic thickness decreased only superficial microhardness, and the physical properties of the material are dependent on the composition thereof / Mestrado / Dentística / Mestra em Clínica Odontológica
43

Dureza da camada de adesivo e da camada híbrida e a sua relação com a resistência de união à dentina / Hardness of the adhesive layer and the hybrid layer and its relationship to bond strength to dentin

Nunes, Paula Mendes Acatauassú 02 September 2013 (has links)
Este estudo avaliou in vitro a dureza da camada de adesivo e da camada híbrida de uma interface entre resina composta e dentina humana por meio de ensaios de nanodureza (DUH). Foi avaliada a resistência de união por meio de testes de microcisalhamento (MC) com o objetivo de observar a relação desta resistência com a propriedade da dureza. Os fatores de variação compreendem quatro sistemas adesivos (Adper Scotchbond Multiuso, Adper Single Bond 2, Clearfil SE Bond e Single Bond Universal) e duas profundidades dentinárias (dentina rasa e dentina profunda). As unidades experimentais foram compostas por 144 fragmentos dentais obtidos da face vestibular de molares humanos, os quais foram distribuídos em 16 grupos, 8 grupos com n=6 para os ensaios de DUH e 8 grupos com n=12 para os ensaios de MC de forma que os quatro sistemas adesivos foram aplicados sobre fragmentos de dentina rasa e de dentina profunda. Após a confecção das restaurações em resina composta e 24h de armazenamento em estufa a 37°C, os ensaios de DUH foram realizados no ultramicrodurômetro DUH-211S (Shimadzu) com carga de 1mN/mseg. Os testes de MC foram realizados na máquina de ensaios universais Instron 5942(Instron Co) com velocidade de 1mm/min seguido da análise do padrão de fratura em microscópio digital. A análise estatística foi realizada por ANOVA (p<0,01%), Tukey e correlação de Pearson (p<0,05%). O sistema SB Universal (M=31,82±4,72) evidenciou os maiores valores de resistência de união e o Clearfil SE (M=26,75±3,73) os menores. O Single Bond 2 (M=28,83±4,07) e Scotchbond MP (M=28,53±4,61) não apresentaram diferenças entre si e obtiveram valores intermediários, não se diferenciando do maior e nem do menor valor. A resistência de união na dentina rasa (M=30,45±4,40) foi maior que em dentina profunda (M=27,52±4,01). Os sistemas SB Universal (M=22,57±2,42) e Scotchbond MP (M=22,13±2,89) não apresentaram diferença entre si e evidenciaram valores de dureza na camada de adesivo maiores que o Clearfil SE (M= 19,11±1,23). O sistema Single Bond 2 (M=20,11±1,49) apresentou valores intermediários de dureza e não foi diferente do maior e do menor valor. A camada híbrida em dentina rasa (M=38,23±3,08) apresentou maior dureza que a camada híbrida em dentina profunda (M=33,09±1,85). Pode-se concluir que tanto o sistema adesivo utilizado quanto a profundidade dentinária influenciaram nos resultados de resistência adesiva. A dureza da camada de adesivo varia conforme o sistema utilizado sendo que os adesivos SB Universal e o Scotchbond MP apresentaram os maiores valores de dureza. A dureza da camada híbrida foi influenciada pela profundidade dentinária do substrato. Foi observada uma correlação direta entre a dureza da camada de adesivo e a resistência adesiva. / This study evaluated in vitro the hardness of the adhesive layer and the hybrid layer interface between composite and human dentin using nanohardness test (DUH). Was evaluated the bond strength by microshear test (MC) in order to observe the relationship of this resistance with the hardness property. The variation factors consist of four adhesive systems (Adper Scotchbond Multi-Purpose, Adper Single Bond 2, Clearfil SE Bond and Single Bond Universal) and two dentin depths (superficial and deep dentin). The experimental units consisted of 144 dental fragments obtained from molars vestibular area, which were divided into 16 groups, 8 groups with n = 6 for DUH test and 8 groups with n = 12 for the MC test, so the four adhesive systems were applied on dentin fragments of superficial and deep dentin. After the construction of the composite resin restorations and 24h storage at 37 °C, DUH analysis were performed using a nanoindentation device DUH-211S (Shimadzu) with load of 1mN/mseg. The MC tests were performed in a universal testing machine Instron 5942 (Instron Co) with speed 1mm/min followed by analysis of the failure site in digital microscope. Statistical analysis was performed by ANOVA (p <0.01%), Tukey, and Pearson correlation (p <0.05%). The system SB Universal (M = 31.82 ± 4.72) showed higher values of bond strength and Clearfil SE (M = 26.75 ± 3.73) lower. The Single Bond 2 (M = 28.83 ± 4.07) and Scotchbond MP (M = 28.53 ± 4.61) did not differ among themselves and had intermediate values, not differentiating the largest and the smallest value. The bond strength of superficial dentin (M = 30.45 ± 4.40) was higher than in deep dentin (M = 27.52 ± 4.01.) Universal Systems SB (M = 22.57 ± 2.42) and Scotchbond MP (M = 22.13 ± 2.89) did not differ among themselves and showed hardness values in the adhesive layer higher than Clearfil SE (M = 19.11 ± 1.23.) The system Single Bond 2 (M = 20.11 ± 1.49) showed intermediate values of hardness and was not different from the largest and smallest value. The hybrid layer in superficial dentin (M = 38.23 ± 3.08) was harder than the hybrid layer in depth dentin (M = 33.09 ± 1.85.) It can be concluded that both the adhesive system used as the dentin depth influenced the bond strength. The hardness of the adhesive layer varies depending on the system used and the SB Universal adhesive and Scotchbond MP showed higher hardness values. The hardness of the hybrid layer was influenced by the depth of the dentin substrate. We observed a direct correlation between the hardness of the adhesive layer and the bond strength.
44

Associação entre fluorescência vermelha emitida pela placa bacteriana e atividade de cárie: estudo in situ / Association between red fluorescence emitted by bacterial plaque and caries activity: in situ study

Bittar, Daniela Gonçalves 08 March 2012 (has links)
O objetivo desse estudo in situ cruzado de duas fases foi avaliar a influência da presença de placa dentária fluorescente no vermelho na indução de lesões cariosas. Foram utilizados 272 blocos de esmalte bovino, que foram avaliados inicialmente em relação à microdureza superficial e quantificação da fluorescência verde com o QLF (Quantitative light-induced fluorescence). Dezessete voluntários utilizaram dispositivos palatais removíveis, com oito amostras cobertas com uma rede plástica para favorecer maior acúmulo de placa. No grupo experimental foi gotejada solução de sacarose a 20%, 8 X ao dia e no grupo controle, água destilada. Cada fase durou 14 dias com 7 dias de wash-out. Os blocos foram avaliados após 4, 7, 10 e 14 dias. Após cada período, a placa bacteriana presente sobre a superfície dos blocos foi analisada utilizando o QLF para a quantificação de fluorescência vermelha. Após cuidadosa limpeza da superfície, o bloco foi novamente avaliado para a perda de fluorescência verde (QLF) e perda de microdureza superficial. Foram realizadas análises de multinível para comparação entre os grupos, bem como análises de regressão linear de multinível entre as medidas de fluorescência vermelha e os desfechos relacionados à desmineralização. Em relação à microdureza de superfície, pode-se observar uma tendência de aumento da perda de dureza entre os diferentes períodos apenas no grupo experimental. Quanto à fluorescência vermelha da placa, houve aumento gradual de acordo com os diferentes períodos em ambos os grupos, sendo esse aumento mais pronunciado no grupo experimental. Houve associação significativa entre as medidas da fluorescência da placa e perda de dureza, independente dos grupos. Em conclusão, a fluorescência vermelha da placa bacteriana está relacionada à placa madura, independente da sua cariogenicidade. / The aim of this two-phase crossover in situ study was to evaluate the influence of presence of red bacterial plaque on the induction of carious lesions. We used 272 bovine enamel blocks, which were initially evaluated in relation to surface microhardness and quantification of green fluorescence using the QLF (Quantitative light-induced fluorescence). Seventeen volunteers to use removable intra-oral appliances were selected, containing eight specimens covered by a plastic net to promote plaque accumulation. 20% sucrose solution, 8 times per day, was dripped in the experimental group, and distilled water was dripped in the control group. Each phase lasted 14 days, with seven days of wash-out. The specimens were assessed after 4, 7, 10 and 14 days. After each period, bacterial plaque present on the blocks surface was analyzed using the QLF to quantify the red fluorescence. After careful cleanness, the block was evaluated again with QLF to assess the loss of green fluorescence and surface microhardness loss. Multilevel analyses were carried out to compare the groups, as well as multilevel linear regression analyses among the red fluorescence and outcomes related to the demineralization. With regard to the surface microhardness, we could observe a trend of hardness loss among the different periods only at the experimental group. In relation to the red fluorescence of plaque, there was a gradual increase according to the different periods in both experimental and control groups, being this increase more relevant in the experimental group. There was significantly association between red fluorescence measurements and microhardness loss, independently of the groups. In conclusion, the red fluorescence of bacterial plaque is related to the mature plaque, independently of its cariogenicity.
45

Avaliação da microdureza dentinária, resistência de união e profundidade de penetração do cimento obturador à dentina radicular após irrigação final com solução de quitosana: estudo ex-vivo, por meio do teste mecânico \"push out\" e microscopia confocal a laser / Evaluation of root dentin microhardness, bond strength and sealer penetration depth after final irrigation with chitosan solution: an ex-vivo study, through \"push out\" mechanical test and laser confocal microscopy

Antunes, Polliana Vilaça Silva 05 November 2015 (has links)
O presente estudo teve como objetivo avaliar, por meio da análise da microdureza dentinária, teste push-out e microscopia confocal a laser, a influência da irrigação final do canal radicular com quitosana 0,2% e EDTA 15% sobre a adesão e penetração do cimento endodôntico através dos túbulos dentinários. Selecionaram-se 50 caninos superiores humanos, os quais após a remoção das coroas foram instrumentados com Reciproc® e hipoclorito de sódio 1%. Os espécimes foram distribuídos em 5 grupos (n=10), conforme protocolo de irrigação final: G1- irrigação convencional com EDTA 15%; G2- EndoVac com EDTA 15%; G3- irrigação convencional com quitosana 0,2%; G4- EndoVac com quitosana 0,2%; G5- grupo controle (sem irrigação final). As raízes foram obturadas pela técnica da condensação lateral com AH Plus e seccionadas transversalmente. O primeiro slice de cada terço foi destinado à resistência de união por cisalhamento por extrusão (RU), e o segundo slice às análises de microdureza dentinária e microscopia confocal a laser. Os dados obtidos foram submetidos à análise estatística descritiva com números absolutos, médias e desvios-padrões e análise de variância de Kruskal-Wallis seguido de teste de Tukey, com significância de 5%. Os resultados mostraram que em todos os grupos houve redução da microdureza dentinária de forma significantemente diferente ao controle (p=0,001). Na comparação intragrupos entre G1, G2 e G3 a penetração de cimento endodôntico no terço cervical foi maior que no apical (p<0,005). No G4 não houve diferença significante entre os três terços (p=0,481). Para a RU, considerando os terços cervical e apical, houve semelhança entre todos os protocolos de irrigação, sendo esses diferentes estatisticamente do grupo controle (p<0,001). Em geral, a resistência de união observada no terço cervical foi estatisticamente superior aos demais terços (p<0,001). No terço cervical dos espécimes em geral, houve predominância de falhas mistas (55,4%) e de falhas adesivas à obturação nos terços médio (58,8%) e apical (56,8%). Concluiu-se que o uso das soluções estudadas, independentemente do protocolo, reduziram a microdureza nos três terços radiculares, favoreceram a penetração do cimento através dos túbulos e aumentaram a adesão do cimento às paredes dentinárias em relação ao controle. / This study aimed to assess, through dentin hardness analysis, push-out tests and laser confocal microscopy, the influence of root canal final irrigation with 0.2% chitosan and 15% EDTA among endodontic cement adhesion and penetration through the dentinal tubules. Fifty human upper canines were selected. After crowns cut off and removal, roots were instrumented with Reciproc® and 1% sodium hypochlorite. The specimens were divided into 5 groups (n = 10) according to final irrigation protocol: G1- conventional irrigation with 15% EDTA; G2-EndoVac use + 15% EDTA; G3- conventional irrigation with 0.2% chitosan; G4-EndoVac use with 0.2% chitosan; G5- control group (without final irrigation). Roots were filled by lateral condensation technique with AH Plus and sectioned transversely. The first slice of each third was reserved for bond strength shear extrusion (SE) tests, and the second slice for dentin microhardness and laser confocal microscopy analysis. Data were submitted to descriptive statistical analysis with absolute numbers, means, standard deviations and Kruskal-Wallis variance analysis followed by Tukey\'s test. A significance level of 5% was considered. Results showed that in all groups there was a reduction in dentin microhardness, with significantly difference if compared with the control group (p=0.001). In intra-groups comparisons between G1, G2 and G3, cervical third sealer penetration was higher than apical third (p<0.005). In the G4 there was no significant difference between thirds (p=0.481). In the SE cervical and apical thirds comparisons, showed to be similar among all irrigation protocols, with statistically difference from the control group (p<0.001). The bond strength observed in the cervical third was statistically higher to the other thirds (p<0.001). In specimens cervical third, there was a predominance of mixed failures (55.4%) and adhesive failures on obturation in the middle (58.8%) and apical (56.8%) thirds. It can be concluded that regardless of the protocol, the studied solutions reduced the microhardness in the three root thirds, favored tubules cement penetration and increased dentin walls cement adhesion if compared to the control group.
46

Avaliação da dureza e módulo de elasticidade da interface de união resina – dentina utilizando a técnica de nanoindentação / Assessment of hardness and elastic modulus of resin-dentin bonding area using the nanoindentation technique

Higashi, Cristian 28 February 2008 (has links)
Made available in DSpace on 2017-07-24T19:22:09Z (GMT). No. of bitstreams: 1 Cristian Higashi.pdf: 1616679 bytes, checksum: a243cd9970614325c2c06ab7c7f592d1 (MD5) Previous issue date: 2008-02-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to assess the hardness and elastic modulus of resin-dentin bonding area formed by an ethanol/water-based (Adper TM Single Bond 2 [SB]) and an acetone-based system (One Step Plus [OS]), under different moisture conditions and application methods. On 24 human molars, a flat superficial dentin surface was exposed by wet abrasion. Two coats of SB or OS adhesive were applied on either a dry (D) or rewetted surface (W), under active (AA) or inactive (IA) application. After polymerization of the adhesives (600 mW/cm2/20 s), composite build-ups were constructed incrementally and specimens were stored in water (24 h). They were cross-sectioned perpendicular to the resin-dentin interface to obtain slices of 1.5 mm thickness that were embedded and polished before the test. Nanoindentations were made on composite resin, adhesive system, hybrid layer and dentin regions. The results of hardness and elastic modulus (GPa) of adhesive system and hybrid layer were analyzed by a three-way ANOVA and Tukey’s multiple comparison tests (α=0.05). The mean and standard deviation of hardness and elastic modulus values of composite resin were (1.02 ± 0.07) and (14.94 ± 0.67) respectively. In dentin, the hardness was (0.69 ± 0.10) and the elastic modulus (17.94 ± 1.84). In the adhesive layer, the highest hardness (0.38 ± 0.06) and elastic modulus (6.93 ± 0.93) of SB were obtained in W group. In this same area, the elastic modulus of OS (5.91 ± 1.12) was lowest in AA group. In the hybrid layer, the hardness of both adhesive systems was highest in AA group, however statistically significant just for OS (0.51 ± 0.2). In D group the highest hardness (0.47 ± 0.24) and elastic modulus (10.98 ± 4.65) of hybrid layer were obtained with AA. It was concluded that the active application of both adhesives in dry dentin resulted in higher hardness and elastic modulus values in the hybrid layer and the moisture increased hardness and elastic modulus values of Adper TM Single Bond 2 in the adhesive layer. / O objetivo deste trabalho foi avaliar a dureza e módulo de elasticidade da interface de união resina-dentina formado por adesivos convencionais de 2 passos à base de água/etanol (Adper TM Single Bond 2 [SB]) e à base de acetona (One Step Plus [OS]), variando a umidade dentinária e forma de aplicação dos mesmos. 24 terceiros molares humanos foram lixados para a obtenção de uma superfície dentinária plana. Duas gotas do adesivo SB ou OS foram aplicadas de forma ativa (AA) ou inativa (AI) sobre uma dentina seca (S) ou reumedecida (U). Após a fotopolimerização dos adesivos (600 mW/cm2 / 20 s) os dentes foram restaurados incrementalmente e armazenados em água destilada por 24 h. Cortes perpendiculares à interface de união foram realizados para obtenção de fatias de aproximadamente 1,5 mm de espessura, que foram embutidas e polidas previamente ao teste. Nanoindentações foram realizadas nas regiões da resina composta, sistema adesivo, camada híbrida e dentina. Os valores de dureza e módulo de elasticidade (GPa) do sistema adesivo e camada híbrida foram submetidos a uma análise de variância de 3 fatores de medidas repetidas e ao teste de comparações múltiplas de Tukey (α=0,05). A média e desvio padrão dos valores de dureza e módulo de elasticidade da resina composta (GPa) foram (1,02 ± 0,07) e (14,94 ± 0,67), respectivamente. Na dentina, a dureza foi (0,69 ± 0,10) e o módulo de elasticidade (17,94 ± 1,84). Na camada de adesivo, os maiores valores de dureza (0,38 ± 0,06) e módulo de elasticidade (6,93 ± 0,93) do SB foram obtidos no grupo U. Nesta mesma região, o módulo de elasticidade do OS (5,91 ± 1,12) foi menor para o grupo AA. Na região da camada híbrida, a dureza de ambos os sistemas adesivos foi maior no grupo AA, porém significativamente somente para o OS (0,51 ± 0,2). No grupo S os maiores valores de dureza (0,47 ± 0,24) e módulo de elasticidade (10,98 ± 4,65) da camada híbrida foram obtidos com AA. Concluiu-se que a aplicação ativa de ambos os sistemas adesivos em substrato dentinário seco resultou nos maiores valores de dureza e módulo de elasticidade na região da camada híbrida e a umidade dentinária influenciou positivamente nos valores de dureza e módulo de elasticidade do sistema adesivo Adper TM Single Bond 2 na região da camada de adesivo.
47

Estudo in vitro da influência da dureza e módulo de elasticidade de sistemas adesivos na resistência de união à dentina humana / In vitro study of influence of hardness and elasticity module of adhesive sistems in bond strenght to human dentin

Bengtson, Camilla Regina Galvão 01 February 2011 (has links)
O objetivo deste trabalho foi avaliar a dureza e o módulo de elasticidade da região de adesão quando utilizados diferentes sistemas adesivos e uma resina composta imediatamente após o procedimento adesivo e após 6 meses de armazenamento, correlacionando esses valores com a resistência adesiva à dentina humana. Para isso foram medidos a dureza e o módulo de elasticidade da resina composta junto à área de união, da camada de adesivo, da camada híbrida, e da dentina adjacente utilizando testes de nanoendentação. Foram utilizados 40 molares humanos hígidos (n=10). Os dentes foram preparados de modo a obterem-se superfícies planas em dentina, sobre as quais os sistemas adesivos foram aplicados seguindo as instruções dos fabricantes. Foram utilizados quatro sistemas adesivos de diferentes formas de aplicação (Adper Scotchbond Multiuso, Adper Single Bond 2, Adper SE Plus e Clearfil SE Bond). Sobre essas superfícies foram inseridos incrementos de resina composta perfazendo 5 mm de altura. Após 24h de armazenamento em água destilada à 37ºC. Os dentes restaurados foram seccionados para obterem-se corpos-de-prova com área aderida de 1mm2. Dos corpos de prova viáveis, 2 palitos centrais de cada dente foram selecionados para análise da nanodureza e do módulo de elasticidade da interface adesiva. Os demais tiveram a resistência de união testada através do teste de microtração, sendo metade desses corpos de prova armazenados durante 6 meses em água à 37ºC. Foi aplicado o teste estatístico ANOVA para dois fatores para todas as variáveis do estudo. Para o fator tempo foi detectada diferença estatística entre os grupos para a resistência adesiva (p=0,042), para o módulo de elasticidade do adesivo (p=0,000) e nanodureza do adesivo (p=0,000), sendo os valores mais baixos observados após 6 meses de armazenamento. Para o fator adesivo, todos os grupos apresentaram diferenças estatísticas (p=0,000), exceto para a variável nanodureza da camada híbrida (p=0,255). O sistema adesivo Clearfil SE Bond apresentou os melhores valores para resistência adesiva e módulo de elasticidade da camada híbrida, juntamente com o sistema Scothbond Multiuso. Os piores desempenhos foram demonstrados pelo sistema adesivo Adper SE Plus. Para a interação, apenas a variável nanodureza do adesivo apontou diferença entre os grupos (p=0,028). O teste de correlação de Pearson detectou correlação significante para as variáveis de módulo de elasticidade, sendo negativa para o módulo de elasticidade do adesivo e positiva para o módulo de elasticidade da camada híbrida. A metodologia e os resultados apresentados permitem-nos concluir que as propriedades mecânicas estudadas (resistência adesiva, módulo de elasticidade do sistema adesivo e da camada híbrida, nanodureza do sistema adesivo e da camada híbrida) podem variar dependendo do sistema adesivo utilizado e do tempo de armazenamento após o procedimento adesivo ter sido realizado. Além disso, quanto maior o módulo de elasticidade da camada híbrida apresentado por um sistema adesivo maior será sua resistência adesiva e menor será o módulo de elasticidade apresentado pela camada de adesivo. / The aim of this study is to evaluate hardness and elasticity module of adhesive region of adhesive systems of different formulations immediately and 6 moths after the adhesive procedures. Those values will be compared to microtensile bond strength to human dentin. The hardness and elasticity module of composite resin next to adhesion region, adhesive layer, hybrid layer and dentin were evaluated. Forty sound human molars were used and prepared in order to obtain flat dentin surfaces in which the adhesive systems were applied following manufactures instructions (n=10). The groups were divided according the four adhesive systems: Adper Scotchbond Multipurpose, Adper Single Bond 2, Adper SE Plus and Clearfil SE Bond. Resin blocks of 5mm were constructed in those surfaces. After 24h of storage in distilled water at 37°C restored teeth were sectioned in order to obtain specimen with a bonded area of around 1mm2. Two specimen of each tooth were submitted to nanohardness and elasticity module test of adhesive interface. Half of the specimen were immediately submitted to the test with a crosshead speed of 0,5mm/min until fracture, the other specimen were stored for additional 6 month in 37ºC water prior to the test. The values resulting of all variables of the study were compared using ANOVA two-way. For the time factor, it was detected statiscal difference between groups in microtensile bond strength values (p=0,042), adhesive elastic modulus (p=0,000) and adhesive nanohardnes (p=0,000), the lowest values were observed in 6 months of storage. For adhesive factor, all groups presented statistical difference (p=0,000), except hybrid layer nanohardness (p=0,255). Clearfil SE bond and Scothbond systems presented the best values of bond strength and hybrid layer elastic modulus. The worse performance was demonstrated by Adper SE Plus adhesive system. For the interaction, only the adhesive nanohardness presents difference between groups (p=0,028). The Pearson correlation test detected positive correlation with microtensile bond strength tests and hybrid layer elastic modulus and negative correlation with bond strength and adhesive elastic modulus. The methodology and the results allow us to conclude that the studied mechanical properties (bond strength, modulus of elasticity of the adhesive and hybrid layer, nanohardness adhesive system and the hybrid layer) may vary depending on the adhesive system and time storage after the bonding procedures have been performed. Moreover, when an adhesive system presents a high elastic modulus of hybrid layer, it will present a high bond strength and low elastic modulus of adhesive layer.
48

Esterelização de esmalte bovino por meio de irradiação por microondas : efeito sobre a microdureza superficial e resistência à desmineralização /

Viana, Patricia Gabriela Sabino. January 2009 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Ana Lúcia Machado / Banca: Mônica Campos Serra / Resumo: Amostras de esmalte provenientes de dentes extraídos, de origem humana ou bovina, são amplamente utilizadas em estudos realizados in vitro e in situ. Esses dentes são considerados uma fonte em potencial de microorganismos patogênicos e devem ser esterilizados, antes da sua utilização nas pesquisas, para prevenir a ocorrência de infecções cruzadas. No entanto, o processo de esterilização do esmalte não deve alterar a sua integridade estrutural. O presente estudo teve como objetivo avaliar a efetividade da irradiação por microondas na esterilização do esmalte bovino, assim como o efeito deste método sobre a microdureza superficial e resistência à desmineralização do esmalte bovino. Dezoito incisivos bovinos foram utilizados para a obtenção de quarenta amostras de esmalte, divididas em dois grupos (n=20): controle (não-irradiados) e irradiados por microondas (3 minutos a 650 W). As amostras do grupo irradiado foram imersas, individualmente, em 200 mL de água destilada e submetidas à irradiação por microondas por 3 minutos a 650 W. Em seguida, ambos os grupos tiveram suas amostras imersas individualmente em tubos estéreis contendo 10 mL caldo BHI (Brain Heart Infusion), os quais foram incubados por 7 dias a 37°C, sob condições de aerobiose e anaerobiose. Após a incubação, o desenvolvimento de microorganismos foi verificado pela presença de turvação do meio de cultura. Em seguida, foram realizadas diluições seriadas (10-2 a 10-5), plaqueamento em meio ágar sangue e incubação em condições de aerobiose e anaerobiose, durante 48 h e 7 dias, respectivamente. Os valores de unidades formadoras de colônias foram calculados. Para a avaliação das propriedades do esmalte, outras 18 amostras de esmalte (4 x 4 mm) foram preparadas, individualmente embutidas em resina acrílica, seqüencialmente polidas e, então, seccionadas em duas metades, sendo uma das metades... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Enamel samples from bovine or human teeth are routinely used for in vitro and in situ caries research. These enamel samples need to be sterilized before they can be used in intra-oral appliances and the sterilization method must not affect the structural integrity of the tooth. The aim of this study was to evaluate the effectiveness of microwave irradiation on bovine enamel sterilization, as well as it's effect on the surface microhardness and resistance to demineralization of bovine enamel. Eighteen bovine incisors were used to produce forty enamel samples, divided in two groups (n = 20): control (nonirradiated) and microwave irradiated (3 minutes at 650 W). Microwaving samples were individually immersed in 200 mL of distilled water and submitted to irradiation at 650 W for 3 minutes. Following the microwaving, specimens from both groups were added individually to 10 mL of Brain Heart Infusion broth in sterile test tubes, which were incubated at 37°C for 7 days under aerobic and anaerobic conditions. After 7 days incubation, those test tubes in which turbidity was observed were considered to contain growing microorganisms. Dilutions of 10-2 to 10-5 were performed on blood agar plates, which were incubated aerobically and anaerobically for growth for up to 48 h and 7 days, respectively. After incubation, the numbers of colonyforming units were calculated. For the properties of enamel analysis, other 18 bovine enamel samples (4 x 4 mm) were prepared, embedded in acrylic resin, serially polished and sliced into two halves: one of the fragments was reserved as control while the other was microwaved in 200 mL of distilled water for 3 minutes at 650 W. Hardness measurements were conducted using a Microhardness tester with a Knoop diamond. Five indentations were performed under a load of 25 gf for 05 seconds. For the resistance to demineralization analysis, the groups were submitted... (Complete abstract click electronic access below) / Mestre
49

AvaliaÃÃo da eficÃcia do LED na fotoativaÃÃo de diferentes resinas compostas / Evaluation of the efficiency of LED in the photactivation of different composite resins

Juliana de Melo Franco 11 September 2007 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / O objetivo deste trabalho foi avaliar in vitro a eficÃcia do aparelho fotoativador LED Elipar Freelight 2 (3M ESPE) na fotoativaÃÃo das resinas compostas Filtek Z350, Z100 e Filtek P60 (3M ESPE), empregando a luz halÃgena (Ultralux â Dabi Atlante) como controle. O grau de conversÃo das resinas utilizadas foi obtido por meio da espectroscopia FT-Raman e por testes de microdureza Vickers. Uma matriz metÃlica com orifÃcio central de 5mm de diÃmetro e 10mm de profundidade foi utilizada para confecÃÃo dos espÃcimes, os quais foram fotoativados uma Ãnica vez por 40s (LH) e 20s (LED) e submetidos ao mÃtodo da raspagem, conforme ISO 4049:2000. TrÃs corpos-de-prova foram confeccionados para cada grupo (n=3). Para realizaÃÃo da microdureza Vickers, os espÃcimes foram embutidos em resina epÃxica e submetidos a um polimento seqÃencial com lixas de granulaÃÃes diferentes. O ensaio de microdureza foi realizado com 48 horas (imediato) e 6 dias (mediato) apÃs a fotoativaÃÃo e os espÃcimes armazenados a temperatura ambiente e ao abrigo da luz. Cinco indentaÃÃes foram realizadas no centro e na periferia do corpo de prova, da superfÃcie de topo para a base, com uma carga de 490,3mN por 15s. A anÃlise direta do grau de conversÃo foi realizada com um espectrofotÃmetro FT-Raman (Bruker, modelo RFS 100/S, excitado com um laser Nd:YAG em 1064nm) por meio da comparaÃÃo das intensidades relativas entre C=C aromÃtica (1610cm-1) e C=C alifÃtica (1640cm-1) nas superfÃcies de topo e base dos corpos-de-prova. A anÃlise estatÃstica (ANOVA, testes Student-Newman-Keuls, tâStudent e Bonferroni) foi realizada para determinar as possÃveis diferenÃas em funÃÃo dos fatores resina, fonte de luz, momento da avaliaÃÃo e superfÃcie analisada. Na comparaÃÃo intragrupo (LED x LH) da microdureza Vickers em 48h, somente o Grupo 2 (Z100) apresentou diferenÃa estatÃstica com maior valor de dureza para a LH (85,51Kg/mm2). Na avaliaÃÃo de 6 dias, todos os grupos apresentaram diferenÃa estatÃstica na comparaÃÃo intragrupo entre as duas fontes de luz, cujo maior valor de dureza (94,39Kg/mm2) foi do Grupo 2 (Z100) quando a LH foi empregada. NÃo houve diferenÃa estatÃstica nos valores de microdureza das superfÃcies de topo e base, nos Grupos 2 (Z100) e 3 (P60), quando o LED foi empregado. Os valores do grau de conversÃo da superfÃcie de topo foram estatisticamente diferentes dos da base. PorÃm, todos os grupos estudados nÃo apresentaram diferenÃa estatÃstica entre as superfÃcies base. Na comparaÃÃo entre as duas fontes de luz, nÃo houve diferenÃa estatÃstica quanto ao grau de conversÃo entre os grupos. Entretanto, o Grupo I (Z350) apresentou o menor grau de conversÃo (53,30 Kg/mm2 ) na superfÃcie de topo, quando a LH foi empregada em relaÃÃo aos Grupos II (Z100) e III (P60). Com base nesses resultados, conclui-se que incrementos de resina composta de atà 2,4 mm de espessura sÃo ideais para se obter valores de microdureza adequados em todas as resinas compostas estudadas; e o LED Elipar Freelight 2 à uma fonte de luz alternativa à luz halÃgena capaz de promover adequado grau de conversÃo de variadas resinas compostas / The aim of this study was to evaluate, in vitro, the efficiency of the light-curing unit LED Elipar Freelight 2 (3M ESPE) on the light-curing composites resin Filtek Z350, Z100 e Filtek P60 (3M ESPE), using the halogen lamp (Ultralux â Dabi Atlante) as a control. The degree of conversion of the used resin was achieved through FT-Raman spectroscopy and through microhardness test Vickers. A cilidrical aluminum mold with diameter of 5mm and a depth of 10mm was used to build the samples, which were photoactivated only once for 40s (LH) and 20s (LED) and submitted to the scrap method, according to ISO 4049:2000. Three samples were built for each group (n=3). The samples were introduced to the epoxy resine and polished with a sequence of different grades of sandpaper to be able to the microhardness test Vickers. The test was done in 48 hours (imediate) and 6 days (mediate), after the photactivation the samples were kept in an ambient temperature and lack of light. Five indentations were made in the centre and the edge of the sample, from the top to the bottom loaded with 490,3mN for 15s. The direct analysis of the degree of conversion was done with a FT-Raman spectroscopy (Bruker, model RFS 100/S, pumped by a laser Nd:YAG in 1064nm) compared with relative intensities between C=C aromatic (1610cm-1) and C=C methacrylate (1640cm-1) on the surfaces of the top and bottom of the sample. The statistic analisys tests (ANOVA, Student-Newman-Keuls, tâStudent and Bonferroni) was done to determinate the possible differences, considering the factors: resin, light source, evaluation moment and surface. Comparing the intragroup (LED x LH) of microhardness Vickers in 48h, only Group 2 (Z100) showed statistics difference with a higher ammount of hardness of the LH (85,51Kg/mm2 ). In the 6 days evaluation, all the groups showed statistics difference, comparing intragroup between two light sources, which the highest ammount of microhardness (94,39Kg/mm2) was from Group 2 (Z100) when LH was applied. There was not statistics differences of the ammount of microhardness of the surfaces on the top and on the bottom, in groups 2 (Z100) e 3 (P60) when LED was applied. The ammounts of the degree of conversion of the top surface were statistically different of the bottom surfaces. All of the studied groups, although, didnÂt show statistics diference between the bottom surfaces. There was not statistics difference about the degree of conversion of the groups, between the two light sources. Although, Group I (Z350) showed the lower degree of conversion (53,30Kg/mm2) on the top surface, when LH was applied comparing to the Group II (Z100) e III (P60). Based on these results, it is concluded that the increments of the composite resin of until 2.4mm of thickness is ideal to obtain ammounts of suitable microhardness in all the composites resin analysed; and the LED Elipar Freelight 2 is an alternative light source wich substitutes the halogen lamp, able to produce suitable degree of conversion in different composites resin
50

AvaliaÃÃo in situ da influÃncia da utilizaÃÃo de diferentes sistemas adesivos no desenvolvimento da cÃrie secundÃria em esmalte / In situ evaluation of secondary caries inhibition promoted by self-etch adhesive systems containing antibacterial agents

Suyane Maria Luna Cruz de Vasconcelos 04 August 2008 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / Os sistemas adesivos atuais apresentam resultados satisfatÃrios no que concerne à adesÃo ao esmalte e à dentina, entretanto, a maior causa de falhas em restauraÃÃes estÃticas ainda à a ocorrÃncia de recidiva de cÃrie ao longo de suas margens. Desta forma, este estudo avaliou a aÃÃo de sistemas adesivos com flÃor e/ou com um novo monÃmero, brometo de metacriloiloxidodecilpiridinio (MDPB) na composiÃÃo microbiolÃgica do biofilme dental e no processo de desmineralizaÃÃo do esmalte adjacente à restauraÃÃo de resina composta, mediante um delineamento in situ, cruzado e duplo-cego. Durante duas fases de 14 dias, dez voluntÃrios utilizaram dispositivos palatinos, contendo, cada um, quatro blocos de esmalte dental humano, restaurados extra-oralmente com resina composta Z250 e um dos seguintes sistemas adesivos: Adperâ Single Bond 2 (condicionamento total, G1), All-Bond SEâ (autocondicionante, G2), One-Up Bond F Plus (autocondicionante com flÃor, G3) e Clearfil Protect Bond (autocondicionante com flÃor e MDPB, G4). Os voluntÃrios foram aleatoriamente divididos entre os grupos, sendo que os que receberam os sistemas adesivos referentes aos grupos G1 e G2, na 1 fase, receberam os tratamentos referentes aos grupos G3 e G4 na 2 fase e vice-versa. Todos os voluntÃrios foram instruÃdos a gotejar sobre os blocos, oito vezes por dia, uma soluÃÃo de sacarose a 20%, simulando um desafio cariogÃnico, e a utilizar um dentifrÃcio fluoretado padronizado trÃs vezes por dia na higienizaÃÃo dentÃria. ApÃs o tÃrmino de cada fase o biofilme formado sobre cada bloco foi coletado e utilizado para a contagem de estreptococos totais, estreptococos mutans e lactobacilos. A perda de mineral foi analisada por meio do teste de microdureza em corte longitudinal do esmalte adjacente à restauraÃÃo. Aplicou-se a anÃlise de variÃncia, ANOVA, nÃo sendo observada diferenÃa estatisticamente significante para a composiÃÃo microbiolÃgica ou desmineralizaÃÃo do esmalte entre os adesivos estudados. Concluiu-se que a incorporaÃÃo de MDPB e/ou flÃor nos sistemas adesivos autocondicionantes nÃo foi capaz, nas condiÃÃes deste estudo, de prevenir a ocorrÃncia da cÃrie secundÃria. / Contemporary adhesives systems present satisfactory bonding to enamel and dentin. However, replacement of the restorations due to secondary caries formation is still a major problem and of great concern in Dentistry. Thus, this study assessed in situ the effects of adhesive systems containing or not fluoride and/or the antibacterial monomer 12-methacryloyloxydodecylpyridinium bromide (MDPB) on the microbiological composition of dental biofilm and on enamel demineralization. During two phases of 14 days each, ten volunteers wore palatal appliances containing four human enamel slabs, which were extra-orally restored using a resin composite (Z250 3M-ESPE) and one of the following adhesive systems: Adperâ Single Bond 2 (total etch, G1); All-Bond SEâ (self-etch, G2); One-Up Bond F Plus (self-etch containing fluoride G3) and Clearfil Protect Bond (self-etch containing fluoride and MDPB, G4). The volunteers were randomly allocated to treatments, and those who received G1 and G2 in the first phase received G3 and G4 in the second one, and vice versa. The volunteers were asked to drop a 20% sucrose solution onto the slabs eight times per day and to use fluoridated dentifrice 3 times per day. The biofilm formed on the slabs was analyzed with regard to total and mutans streptococci as well as lactobacilli counts. Demineralization was determined on enamel around the restorations by cross-sectional microhardness. The data were analyzed by analysis of variance, ANOVA. No differences were found for microbiological composition or enamel demineralization among the studied adhesive systems. It can be concluded that that fluoride or MDPB addition to adhesives systems presented no effect in controlling caries around resin restorations in this in situ model.

Page generated in 0.0662 seconds