• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 74
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 76
  • 76
  • 53
  • 47
  • 26
  • 15
  • 15
  • 13
  • 13
  • 11
  • 11
  • 11
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Avaliação da qualidade óssea no reparo de defeitos ósseos sob a ação do risedronato e da deficiência estrogênica

Senra, Giselle Segnini [UNESP] 24 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:24Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-24Bitstream added on 2014-06-13T19:44:11Z : No. of bitstreams: 1 senra_gs_dr_sjc.pdf: 2645551 bytes, checksum: ee01850aed262e3ecbee732d745d1025 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O aumento da expectativa de vida amplia as possibilidades de doenças como a osteoporose, que elevam a ocorrência de fraturas e demandam longo tratamento. Nos últimos anos, muita atenção tem sido dada aos efeitos potenciais dos medicamentos para a osteoporose na reparação de fraturas advindas desta doença. O objetivo deste trabalho foi avaliar o efeito do Risedronato (10,5 mg/kg/semana) na qualidade óssea do reparo ósseo em ratas com deficiência estrogênica. Para isso, 84 ratas foram submetidas à ovariectomia e 42 ratas à cirurgia sham. Após 35 dias, lesões de 2,5 mm foram realizadas nos fêmures quando, então, se iniciou a medicação. Os animais ovariectomizados foram divididos em dois grupos, um recebendo risedronato e o outro recebendo água filtrada como placebo. Os animais foram sacrificados com 18, 45 e noventa dias de reparo. Cortes centrais dos defeitos de metade das ratas receberam análise morfológica ao MEV, teste de microdureza Vicker’s e através do μED-XRF foi realizado mapeamento, micro-análise semi-quantitativa do Ca e P do mineral ósseo e relação Ca/P. A outra metade dos animais, com o fêmur esquerdo operado (O) e o direito não-operado (NO), teve esses ossos congelados até a realização de ensaio de flexão em três pontos gerando valores de força máxima, rigidez e energia da força máxima. Para a análise estatística foram utilizados os testes: t-Student, Análise de Variância ANOVA, Comparação Múltipla de Tukey e Correlação Linear, todos com nível de significância de 5%. A microdureza (HV) se mostrou fortemente relacionada com as concentrações de Ca e de P, e moderadamente correlacionada com Ca/P. A ovariectomia não afetou os valores de microdureza e módulo de elasticidade (E), mas diminuiu a concentração de Ca, de P e a relação Ca/P aos 18 dias. O tratamento com risedronato aumentou os valores de HV e E, mas não interferiu... / The increase in life expectancy is associated with a higher osteoporosis incidence, which elevates the occurrence of bone fractures, and demand long treatment. In the last years, it’s increasing de interest in the potential effects of osteoporosis medication on bone fractures healing. The aim of this work will be to evaluate the effects of Risedronate (10,5 mg/Kg/week) on bone quality in the femoral callus in rats with induced osteopenia. For that, 84 rats were subject to ovariectomy, and 42 were sham operated. After 35 days, 2,5 mm monocortical bone lesions were drilled on all animals femurs. Then, treatment began. The ovariectomized animals, divided in two groups, received Risedronate or drinking water as a placebo. The animals were sacrificed at 18, 45 and ninety days of bone repair. The central sections from bone defects from half of the rats were analyzed to determine their morphology using an SEM, electron probe microanalysis (μED-XRF) from bone mineral Ca, P and Ca/P ratio and Vicker’s microhardness. Another half of the animals had the left femur operated (O), and the right one, non operated (NO), both frozen till be tested in threepoint flexure to derive maximum load, stiffness and energy absorbed to maximum load. Statistical analyses were performed using t-Student, ANOVA, Tukey and Linear Correlation tests, considering 5% significance. Microhardness was strongly correlated to Ca and P concentrations but it was moderately correlated with Ca/P. Ovariectomy didn’t affect microhardness (HV) and Young modulus (E) but diminished, at 18 days, Ca/P, Ca and P concentrations. Risedronate treatment achieved increasing in HV and E without interference on Ca/P, Ca and P concentration of bone callus. Ovariectomy and healing time almost didn’t have influence on biomechanical properties of O, different from risedronate, which diminished these properties at 18 and 45 days. The HV and E from... (Complete abstract click electronic access below)
32

Ação do peróxido de hidrogênio 35% sobre a morfologia do esmalte e sua interferência do processo des-remineralização: estudo in situ

Arruda, Alex Mendez de [UNESP] 11 June 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-06-11Bitstream added on 2014-06-13T18:51:39Z : No. of bitstreams: 1 arruda_am_me_araca.pdf: 646025 bytes, checksum: 136184311e9ba76436388867a2d8dcc5 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este trabalho analisou in situ o efeito de um clareador a base de peróxido de hidrogênio a 35%, na microdureza superficial em esmalte bovino. Para tanto, 100 fragmentos dentais com dimensões de 4x4x2mm, foram polidos e submetidos à leitura inicial de microdureza Knoop. Foram selecionados os 44 fragmentos com microdureza mais próxima da mediana e estas unidades experimentais foram aleatoriamente divididas em grupos de 4 elementos que foram adaptados a aparelhos moveis usados por 11 indivíduos. Os voluntários foram orientados a utilizar o dispositivo durante todo o dia, com exceção dos momentos destinados à alimentação, higienização e às sessões clareadoras. Metade dos fragmentos de cada dispositivo foi submetida a uma sessão de clareamento (3 aplicações de 15 minutos) por semana, durante 14 dias, totalizando 3 sessões clareadoras. Os fragmentos não clareados permaneceram no dispositivo sem sofrer qualquer tipo de influência do clareador. Durante o uso do aparelho os fragmentos dentais foram submetidos ao acúmulo bacteriano, sendo gotejada uma gota da solução de sacarose a 20% em cada bloco, oito vezes ao dia, visando aumentar o desafio cariogênico. Após 7 dias, do término dos tratamentos foi realizada nova análise da microdureza e os valores foram submetidos à Análise de Variância ao nível de 5%. Pôde-se observar diminuição nos valores de microdureza, tanto para o grupo clareado (média: 238,9 – 179,4), quanto para o grupo controle (média: 237,3 – 191,7), sendo as médias mais baixas encontradas no grupo clareado. Concluiu-se que o tratamento clareador com peróxido de hidrogênio a 35% potencializou a redução da microdureza em dentes submetidos ao desafio cariogênico / This in situ study analyzed the effect of bleaching using 35% hydrogen peroxide on the enamel microhardness. Therefore, 100 dental fragments with dimensions of 4x4x2mm, were polished and subjected to the initial reading of microhardness. We selected 44 fragments presenting microhardness data similar to the mean value and these experimental units were randomly divided into groups of four elements that have been adapted in mobile devices to be worn by 11 volunteers. They were instructed to use the device throughout the day, except in meal times, cleaning and whitening sessions. Bleaching procedures were performed in half of the fragments placed on each device (3 applications of 15 minutes) per week for 14 days, totalizing 3 whitening sessions. Unbleached fragments remained on the device without suffering any kind of influence of the bleaching agent. While using the appliance, dental fragments were lead to bacterial colonization; sine a 20% sucrose solution was dripped eight times a day, aiming to increase the cariogenic challenge. After seven days of the end of the treatment, microhardness \analysis was performed. Data were submitted to ANOVA and Fisher's test at 5%. It was observed a decrease in microhardness values for both bleached group (mean: 238.9 to 179.4) and control group (mean: 237.3 to 191.7), besides that, the lowest values were verified in the bleached groups. It was concluded that bleaching using 35%hydrogen peroxide potentiated the reduction in microhardness in teeth submitted to cariogenic challenge
33

Influência da temperatura sobre a microdureza de uma resina composta fotoativada com luz halógena e Leds

Cáceres Benítez, Pablino [UNESP] 31 August 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-08-31Bitstream added on 2014-06-13T19:51:22Z : No. of bitstreams: 1 caceresbenitez_p_me_arafo.pdf: 539913 bytes, checksum: 4b2674880d3cfaa5af955bceb1ed75eb (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O objetivo desta pesquisa foi avaliar a influência de várias temperaturas sobre os valores de microdureza de topo e base de uma resina composta fotopolimerizável comercialmente disponível, variando o tipo de fonte de luz (LEDs e lâmpada halógena). As temperaturas testadas foram 25, 35, 45, 55, 65, 80, 90 e 100º C. A resina composta utilizada foi a Z100 (3M). Com o auxílio de uma matriz metálica foram confeccionados 3 corpos-de-prova de 2 mm de espessura e 9,8 mm de diâmetro para cada temperatura. Os corpos-de-prova foram polimerizadas LEDs (60 s) ou lâmpada halógena (40 s) enquanto eram submetidas às diferentes temperaturas, após a polimerização as amostras foram armazenadas a seco, em estufa a 37º C. Após 24 horas as amostras foram submetidas ao teste de microdureza Vickers no topo e na base. Baseados nos resultados conclui-se que com a elevação da temperatura aumentou o valor da dureza Vickers com correlação linear positiva e com ambos aparelhos; o valor da dureza de topo foi sempre superior à dureza de base independentemente da fonte de luz ou temperaturas empregadas; o aparelho de luz halógena só se mostrou superior à fonte de LEDs na região de base dos corpos-de-prova. / The aim of this research was to evaluate the influence of several temperatures on the microhardness values of top and base of a light curing composites resin commercially available, varying the type of light source (LEDs and halogen lamp). The tested temperatures were 25, 35, 45, 55, 65, 80, 90 and 100º C. The composite resin used was Z100 (3M). With the aid of a metallic mould were made three samples of 2 mm of thickness and 9,8 m diameter for each temperature. The samples were light cure while they where submitted to the different temperatures with LEDs (60 s) and halogen lamp (40 s), after the polymerization the samples were dry stored in a stove at 37º C. After 24 hours, the samples were submitted to the Vickers microhardness test in the top and in the base. Based on the results it was concluded that with the elevation of the temperature increased the Vickers hardness value with positive linear correlation on both devices. The hardness value of the top was always superior to the base hardness, independently of the light source or used temperatures. The halogen lamp source was superior to the source of LEDs in the area of base of the samples.
34

Esterelização de esmalte bovino por meio de irradiação por microondas: efeito sobre a microdureza superficial e resistência à desmineralização

Viana, Patricia Gabriela Sabino [UNESP] 27 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-27Bitstream added on 2014-06-13T19:17:33Z : No. of bitstreams: 1 viana_pgs_me_arafo.pdf: 840842 bytes, checksum: 18e582ab40c3b9552459a495ba07430b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Amostras de esmalte provenientes de dentes extraídos, de origem humana ou bovina, são amplamente utilizadas em estudos realizados in vitro e in situ. Esses dentes são considerados uma fonte em potencial de microorganismos patogênicos e devem ser esterilizados, antes da sua utilização nas pesquisas, para prevenir a ocorrência de infecções cruzadas. No entanto, o processo de esterilização do esmalte não deve alterar a sua integridade estrutural. O presente estudo teve como objetivo avaliar a efetividade da irradiação por microondas na esterilização do esmalte bovino, assim como o efeito deste método sobre a microdureza superficial e resistência à desmineralização do esmalte bovino. Dezoito incisivos bovinos foram utilizados para a obtenção de quarenta amostras de esmalte, divididas em dois grupos (n=20): controle (não-irradiados) e irradiados por microondas (3 minutos a 650 W). As amostras do grupo irradiado foram imersas, individualmente, em 200 mL de água destilada e submetidas à irradiação por microondas por 3 minutos a 650 W. Em seguida, ambos os grupos tiveram suas amostras imersas individualmente em tubos estéreis contendo 10 mL caldo BHI (Brain Heart Infusion), os quais foram incubados por 7 dias a 37°C, sob condições de aerobiose e anaerobiose. Após a incubação, o desenvolvimento de microorganismos foi verificado pela presença de turvação do meio de cultura. Em seguida, foram realizadas diluições seriadas (10-2 a 10-5), plaqueamento em meio ágar sangue e incubação em condições de aerobiose e anaerobiose, durante 48 h e 7 dias, respectivamente. Os valores de unidades formadoras de colônias foram calculados. Para a avaliação das propriedades do esmalte, outras 18 amostras de esmalte (4 x 4 mm) foram preparadas, individualmente embutidas em resina acrílica, seqüencialmente polidas e, então, seccionadas em duas metades, sendo uma das metades... / Enamel samples from bovine or human teeth are routinely used for in vitro and in situ caries research. These enamel samples need to be sterilized before they can be used in intra-oral appliances and the sterilization method must not affect the structural integrity of the tooth. The aim of this study was to evaluate the effectiveness of microwave irradiation on bovine enamel sterilization, as well as it's effect on the surface microhardness and resistance to demineralization of bovine enamel. Eighteen bovine incisors were used to produce forty enamel samples, divided in two groups (n = 20): control (nonirradiated) and microwave irradiated (3 minutes at 650 W). Microwaving samples were individually immersed in 200 mL of distilled water and submitted to irradiation at 650 W for 3 minutes. Following the microwaving, specimens from both groups were added individually to 10 mL of Brain Heart Infusion broth in sterile test tubes, which were incubated at 37°C for 7 days under aerobic and anaerobic conditions. After 7 days incubation, those test tubes in which turbidity was observed were considered to contain growing microorganisms. Dilutions of 10-2 to 10-5 were performed on blood agar plates, which were incubated aerobically and anaerobically for growth for up to 48 h and 7 days, respectively. After incubation, the numbers of colonyforming units were calculated. For the properties of enamel analysis, other 18 bovine enamel samples (4 x 4 mm) were prepared, embedded in acrylic resin, serially polished and sliced into two halves: one of the fragments was reserved as control while the other was microwaved in 200 mL of distilled water for 3 minutes at 650 W. Hardness measurements were conducted using a Microhardness tester with a Knoop diamond. Five indentations were performed under a load of 25 gf for 05 seconds. For the resistance to demineralization analysis, the groups were submitted... (Complete abstract click electronic access below)
35

Influência de soluções fluoretadas na estabilidade de cor, rugosidade e dureza superficial de resinas compostas em função do tempo /

Oliveira, Ana Luísa Botta Martins de. January 2012 (has links)
Orientador: Elisa Maria Aparecida Giro / Co-orientador: Patricia Petromilli Nordi Sasso Garcia / Banca: Patricia Aleixo dos Santos Domingos / Banca: Jacqueline Braga Barbosa Cerqueira-Leite / Banca: Victor Humberto Orbegoso Flores / Banca: Edson Alves Campos / Resumo: O objetivo deste estudo foi avaliar a influência de soluções fluoretadas sobre a estabilidade de cor, a rugosidade e a dureza superficiais de diferentes resinas compostas, em curto e em longo prazo. Para isso, foram realizadas pesquisas científicas, apresentadas em três capítulos. Setenta e cinco espécimes de 10 mm de diâmetro e 2 mm de espessura foram confeccionados e polidos com discos de óxido de alumínio (Super-Snap®, Shofu Dental Corp. Kyoto, Japão) em ordem decrescente de granulação. Os grupos experimentais foram divididos de acordo com o tipo de resina composta (nanoparticulada - Filtek Z350 XT, microhíbrida - Filtek Z250 e microparticulada - Durafill VS) e diferentes meios de imersão (saliva artificial, solução de fluoreto de sódio a 0,05%- manipulado, Fluordent Reach, Oral B, Fluorgard). Os espécimes permaneceram imersos em saliva artificial por 24 horas e foram submetidos à análise da cor, rugosidade e dureza iniciais. A partir disso, foram imersos nas diferentes soluções por 1 minuto ao dia durante 60 dias. Nos intervalos entre as imersões foram mantidos em saliva artificial a 370C  1 0C. Após esse período, foram submetidos às novas avaliações de cor, rugosidade e dureza superficiais. Em sequência, foram realizados os procedimentos de envelhecimento artificial utilizando-se 20.000 ciclos de termociclagem, 1.200.000 ciclos de simulação de forças mastigatórias e imersão contínua nas soluções por 1825 minutos. Após estes processos, foram realizadas leituras finais para todas as propriedades avaliadas. Os dados obtidos, nos diferentes tempos, foram avaliados estatisticamente pela Análise de Variância. Para a estabilidade de cor, utilizou-se o teste de Tukey e para a rugosidade e a dureza superficiais, os testes de Tukey e de Sidak... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the influence of fluoride solutions on color stability, surface roughness and hardness of different composite resins, in short and long term. Seventy-five specimens of 10mm diameter and 2mm thickness were made with composite resins and polished with aluminum oxide discs (Super-Snap®, Shofu Dental Corp. Kyoto, Japan) in a decreasing order of granulation. Experimental groups were divided according to (1) composite resin (nanofilled- Filtek Z350 XT, mycrohybrid Filtek Z250 and microfilled - Durafill VS) and (2) different immersion media (artificial saliva, a manipulated 0.05% sodium fluoride solution, Fluordent Reach, Oral B, Fluorgard). Specimens were kept in artificial saliva for 24 hours and submitted to color, roughness and hardness tests. From this period, specimens were immersed in the different solutions for 1 minute per day, during 60 days. In periods between immersions, specimens were kept in artificial saliva at 370C  10C. After that, the specimens were submitted to color, roughness and hardness analysis again. Then the artificial aging was carried out using 20,000 thermal cycles, 1,200,000 mechanical loading cycles and continuous immersion in the solutions for 1825 minutes. After the artificial aging, specimens were submitted to color stability, roughness and hardness tests. The obtained data for different periods were submitted to ANOVA. The color change data were evaluated by Tukey test. Surface roughness and hardness data were submitted to Tukey and Sidak tests, both at 5% significance. The highest color change and surface roughness were observed with the microfilled composite resin, followed by the nanofilled and microhybrid resin. Besides that, the lowest hardness also was obtained with the microfilled resin. The artificial aging promoted an increase of roughness and... (Complete abstract click electronic access below) / Doutor
36

Avaliação de uma nova composição de agente clareador sobre a microdureza do esmalte : associação do trimetafosfato de sódio e fluoreto de sódio ao peróxido de hidrogênio a 10% /

Santos, Ana Laura Esteves dos. January 2014 (has links)
Orientador: Mirela Sanae Shinohara / Banca: Alberto Carlos Botazzo Delbem / Banca: Mário Fernando de Goes / Resumo: Objetivos: avaliar a ação do trimetafosfato de sódio (TMP)+fluoreto de sódio (NaF) em duas concentrações 3%TMP+0,1%NaF e 0,3%TMP+0,05%NaF, adicionados ao peróxido de hidrogênio (PH) 10%, em inibir a desmineralização do esmalte em contato com dentifrício fluoretado (DF) ou não (DP). Métodos: Blocos de esmalte bovino (4.0 x 4.0 mm) foram obtidos, planificados e polidos para leitura da microdureza superficial Knoop (SH) inicial (25g/5seg). 72 blocos selecionados (320-380KHN) foram divididos aleatoriamente em 6 grupos (n=12), de acordo com o gel clareador e o dentifrício: PH+DF; PH+3TMP+0,1NaF+DF; PH+0,3TMP+0,05NaF+DF; PH+DP; PH+3TMP+0,1NaF+DP; PH+0,3TMP+0,05NaF+DP. O clareamento foi realizado por 30min/dia, seguido da imersão das amostras em dentifrício (1min) durante 14 dias e entre as sessões, mantidos em saliva artificial à 37oC. Em seguida, foi realizada a leitura da SH final e os blocos foram seccionados ao meio para análise da dureza em profundidade (ΔKHN) (5g/5seg). O cálculo da perda de dureza foi realizado a partir dos valores de SH/ΔKHN e submetidos à análise estatística. Imagens de Microscopia de Luz Polarizada (MLP) foram obtidas do corte longitudinal das amostras. Resultados: O PH+3TMP+0,1NaF+DF demonstrou os melhores resultados, seguido pelo PH+0,3TMP+0,05NaF+DF. O PH+DF e PH+DP apresentaram os menores valores de SH/ΔKHN. No entanto, a ΔKHN do PH+DF foi estatisticamente superior ao do PH+DP. As imagens qualitativas de MLP mostraram nitidamente uma desmineralização subsuperficial para os grupos PH+DF e PH+DP. Significância: A adição do TMP+NaF ao gel de PH foi eficaz na diminuição da perda de dureza. A aplicação do SF foi benéfica à ação do TMP+NaF no gel clareador. / Abstract: Objectives: To evaluate the effects of sodium trimetaphosphate (TMP) + sodium fluoride (NaF) in two concentrations 3%TMP+0.1%NaF and 0.3%TMP+0.05%NaF, added to hydrogen peroxide (HP) 10% by inhibiting demineralization of enamel in contact with fluoridated dentifrice (FD) or not (PD). Methods: Bovine enamel blocks (4.0 x 4.0 mm) were flat and polished in order to perform the initial Knoop surface microhardness (SH) analysis (25g/5s). Seventy two selected blocks (320-380KHN) were randomly assigned into 6 groups (n=12), according to the bleaching gel and slurry: HP+FD; HP+3TMP+0.1NaF+FD; HP+0.3TMP+0.05NaF+FD; HP+PD; HP+3TMP+0.1NaF+PD; HP+0.3TMP+0.05NaF+PD. Bleaching was carried out 30min/day, followed by immersing the samples in dentifrice (1min) for 14 days and between sessions, stored in artificial saliva at 37oC. Then, the final SH reading was taken and the blocks were cut in halves to analyze cross-sectional hardness (ΔKHN) (5g/5s). The calculation of the loss of microhardness (%SH) was carried out from the values of SH/ΔKHN and subjected to statistical analysis. Images from Polarized Light Microscopy (PLM) were obtained from the longitudinal section of the samples. Results: HP+3TMP+0.1NaF+FD showed the best results, followed by HP+0.3TMP+0.05NaF+FD. HP+FD and HP+PD showed the lowest values of %SH/ΔKHN. However, ΔKHN of HP+FD was statistically higher than HP+PD. Qualitative PLM images clearly showed subsurface demineralization for groups HP+FD and HP+PD. Conclusion: The addition of TMP+NaF to the gel of HP was effective in reducing the loss of hardness. Applying FD was beneficial to the action of TMP+NaF of the bleaching gel. / Mestre
37

Avaliação da dureza e do módulo de elasticidade do osso mandibular submetido à distração osteogênica e à LLLT: estudo preliminar em ovelhas

Freddo, Angelo Luiz January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:08Z (GMT). No. of bitstreams: 2 000424484-0.pdf: 12584409 bytes, checksum: ce100d293e186ae476b96a04abe84099 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Introduction: Distraction osteogenesis is a treatment approach designed to induce new bone formation in vascularized bone surfaces through the use of functional devices and the application of slow and progressive traction forces. Objectives: To validate the use of nanoindentation tests in research protocols involving animals and to assess the quality of newly formed bone in sheep mandibles submitted to distraction osteogenesis and low-level laser therapy (LLLT) based on hardness and modulus of elasticity values. We also aim to determine the best moment for the application of laser therapy, i. e., during the latency/activation or consolidation periods, and to assess the dimensions of newly formed bone with the use of computed tomography. Background data: Nanobiotechnology is an emerging concept in the field of science and technology that has a potential to radically change the criteria currently used to assess the quality of bone formed after distraction osteogenesis. Methods: Extraoral distraction devices were placed in five sheep so as to achieve 1. 5 cm of lengthened bone in 60 days. Distraction devices were removed 50, 40, and 33 days after surgery. Four animals were also treated with eight applications of infra-red laser (830ŋm), each 48 hours, in three equidistant spots, with 5Jcm2 and 50mW of potence, at different times. One was used as control (no laser therapy). The newly formed bone was submitted to nanoindentation tests for the assessment of hardness and modulus of elasticity and a computed tomography to bone contraction evaluation. Results: When applied in the bone consolidation period, LLLT caused an increase in hardness and modulus of elasticity values. On the other hand, animals irradiated with LLLT during the activation period presented lower values. Computed tomography revealed that the animals using the devices for 33 days presented contraction of the newly formed bone. Conclusions: Nanoindentation tests were able to detect slight abnormalities in bone metabolism and proved to be important tools for the assessment of bone quality after distraction osteogenesis. LLLT provides increased benefits when applied during the bone consolidation period, once it promotes an increase in hardness and modulus of elasticity values. The bone consolidation period should be of at least 3 weeks, so as to prevent bone contraction. / Introdução: A distração osteogênica é um processo terapêutico para induzir neoformação tecidual entre superfícies ósseas vascularizadas, por meio de uma força lenta e progressiva de tração, através de aparelhos funcionais. Objetivos: Validar a utilização dos testes de nanoindentação em pesquisas com modelo experimental não humano, a fim de conhecer a qualidade do osso mandibular neoformado em ovelhas submetidas à distração osteogênica e à terapia a laser de baixa potência (LLLT), baseado nos valores de dureza e módulo de elasticidade. Complementarmente, objetiva-se conhecer o momento mais benéfico para irradiação do laser, se na fase de latência/ativação ou maturação. Ademais, foram realizadas tomografias computadorizadas para avaliar a dimensão de osso neoformado e verificar possíveis contrações desse alongamento. Contexto de Pesquisa: A nanobiotecnologia é um campo emergente da ciência e da tecnologia que tem o potencial para transformar radicalmente, por meio de novos conhecimentos, os critérios atualmente utilizados para conhecer a qualidade do osso formado por distração osteogênica. Materiais e Métodos: Cinco ovelhas foram utilizadas e nelas instalados distratores extra-bucais, com intuito de neoformar 1,5 cm de osso em 60 dias de observação, sendo que os distratores eram removidos aos 50, 40 e 33 dias de pósoperatório. Quatro animais foram irradiados com LLLT infravermelho (830 ŋm), tendo recebido oito aplicações, a cada 48 horas, com três pontos de 5J/cm2 e potência de 50mW, em diferentes períodos terapêuticos; o quinto foi o controle, sem tratamento LLLT. As peças ósseas foram submetidas a testes de nanoindentação para aferir módulo de elasticidade e dureza das amostras e a tomografias computadorizadas para avaliar a contração óssea. Resultados: A LLLT quando utilizada na fase de maturação do osso, promoveu aumento da dureza e do módulo de elasticidade. Por outro lado, os animais irradiados com LLLT durante o período de latência/ativação apresentaram menores valores de dureza e módulo de elasticidade. A análise tomográfica complementar demonstrou que, nos animais com manutenção do distrator por 33 dias, ocorreu contração do osso neoformado. Conclusões: A nanoindentação é um teste capaz de captar as mínimas alterações do metabolismo ósseo e, portanto, uma importante ferramenta na aferição da qualidade do osso em procedimentos de distração osteogênica. A LLLT é mais benéfica quando aplicada no período de maturação do osso, pois promove aumento da dureza e do módulo de elasticidade. O período de consolidação óssea com permanência do distrator deve ser de, no mínimo, três semanas, a fim de prevenir contração do tecido ósseo alongado.
38

Análise do efeito de adição do marcador Rodamina B em propriedades mecânicas de sistemas adesivos não simplificados / Analysis of the effect of addition of Rhodamine B marker on mechanical properties of non-simplified adhesives

Camila Moreira Machado 12 December 2014 (has links)
Este estudo in vitro avaliou o efeito da adição de rodamina B dissolvida em etanol nas concentrações de 0,02mg/mL e 0,10mg/mL, nas propriedades mecânicas dos sistemas adesivos não simplificados considerados padrão-ouro. 96 coroas de terceiros molares humanos hígidos foram seccionadas transversalmente no terço oclusal para remoção do esmalte e exposição da dentina. Os espécimes foram divididos de acordo com os sistemas adesivos Adper Scotchbond Multi-Purpose (MP) - convencional de três passos ou Clearfil SE Bond (SE) - autocondicionante de dois passos: MP-C e SE-C (MP e SE controles); MP-C1 e SE-C1 (MP e SE com rodamina B 0,02mg/mL); MP-C2 e SE-C2: (MP e SE com rodamina B 0,10mg/mL). Para o teste de RU, os espécimes (n=10) foram submetidos ao desgaste com lixas de granulação 320 e 600. A dentina foi tratada de acordo com as instruções de cada fabricante dos sistemas adesivos e restaurada com resina composta FiltekTM Z250. Após o armazenamento em saliva artificial (7dias/37oC), os espécimes foram seccionados para obtenção de palitos com 0,64 mm2 de área média e submetidos ao teste de microtração em máquina de teste universal a 0,5 mm/min, que foram analisados após 7 dias e 6 meses. O modo de fratura dos espécimes foi analisado com estereomicroscópio digital (x200) e classificado em: adesiva, coesiva em dentina, coesiva em resina e mista. Para o teste de MS, as coroas seccionadas (n=6) foram planificadas com lixa de granulação 600. A dentina foi tratada de acordo com as instruções de cada fabricante dos sistemas adesivos e os espécimes foram mantidos secos em estufa a 37oC durante 48 horas. O teste de MS foi realizado utilizando ponta Knoop (Microdurômetro Shimadzu HMV-2), a 10x e carga estática de 25gF por 10 segundos. Os resultados obtidos foram analisados por análise de variância (ANOVA-2 critérios) e teste de Bonferroni para comparações múltiplas (p<0,05). A análise de acordo com o tempo foi realizada com o teste de t-student. Os valores médios de RU e desvio padrão (MPa±dp; 7 dias / 6 meses) foram: MP-C (41,95±2,38 / 22,76±3,66); MP-C1 (28,02±5,12 / 17,93±5,70); MP-C2 (26,28±5,55 / 14,30±5,68); SE-C (46,07±1,43 / 19,07±6,75); SE-C1 (37,49±13,31 / 18,54±6,71); SE-C2 (34,16±7,71 / 17,89±4,87). No tempo de 7 dias, os fatores sistema adesivo e concentração de rodamina B foram significantes. Após 6 meses, apenas o fator concentração de rodamina B foi significante. A falha de fratura predominante em todos os grupos foi adesiva. Os valores de MS (KHN) e desvio padrão foram: MP-C (8,97±3,85); MP-C1 (7,33±0,99); MP-C2 (7,17±2,45); SE-C (4,71±4,42); SE-C1 (4,42±0,56); SE-C2 (3,27±0,30). Na comparação entre os sistemas adesivos, eles diferiram entre si na condição controle e de 0,10mg/mL. Para cada adesivo, não houve diferença entre as distintas condições de acordo com a adição de rodamina B. Em função dos resultados apresentados, a adição de rodamina B nos sistemas adesivos não simplificados MP e SE, nas concentrações de 0,02mg/mL e 0,10mg/mL, deve ser incorporada com cautela para que não influencie nas propriedades mecânicas do material. / This in vitro study evaluated the effect of addition of rhodamine B dissolved in ethanol in concentrations of 0.02mg/mL and 0.10mg/mL, the mechanical properties of non-simplified adhesive systems. 96 crowns of human third molars were transversely sectioned on the oclusal third to remove the enamel and exposure the dentin. The specimens were divided according to the adhesive systems Adper Scotchbond Multi-Purpose (MP) 3-step-etch-andrinse or Clearfil SE Bond (SE) 2-step-self-ecthing: MP-C and SE-C (MP and SE controls); MP-C1 and SE-C1 (MP and SE with 0.02mg/mL rhodamine B); MP-C2 and SE-C2: (MP and SE with 0.10mg/mL rhodamine B). For the &#x3BC;TBS test, the specimens (n=10) were ground with 320- to 600-grit silicon carbide paper. The dentin was treated according to the instructions of each manufacturer and restored with composite resin FiltekTM Z250. The specimens were stored in artificial saliva (7 days/37oC), and then sectioned to obtain sticks with an average of 0.64 mm2 area and submitted to &#x3BC;TBS test at a universal testing machine at 0.5 mm/min, which were analyzed immediately after 7 days and 6 months. The mode of fracture of the specimens was analyzed with digital stereomicroscope (x200) and classified as: adhesive, cohesive in dentine, cohesive in resin and mixed. For the SM test, the sectioned crowns (n=6) were flattened with 600-grit silicon carbide paper. The dentin was treated according to the manufacturers instructions for each adhesive system and the specimens were stored in dry condition at 37oC during 48 hours. The SM test was performed with Knoop indenter (Shimadzu HMV-2 hardness tester), at 10x and 25gF of load for 10 seconds. The results were analyzed by two-way analysis of variance tests and the Bonferroni test for multiple comparisons (p<0.05). The analysis regarding time was checked with t-student test. The mean &#x3BC;TBS and standard deviation (MPa±dp; 7 days / 6 months) were: MP-C (41.95±2.38 / 22.76±3.66); MP-C1 (28.02±5.12 / 17.93±5.70); MP-C2 (26.28±5.55 / 14.30±5.68); SE-C (46.07±1.43 / 19.07±6.75); SE-C1 (37.49±13.31 / 18.54±6.71); SE-C2 (34.16±7.71 / 17.89±4.87). In the immediate time, the adhesive system and rhodamine B concentration factors were significant. After 6 months, only the rhodamine B concentration was a significant factor. The predominant failure in all groups was adhesive. The values of SM and standard deviation were: MP-C (8.97±3.85); MP-C1 (7.33±0.99); MP-C2 (7.17±2.45); SE-C (4.71±4.42); SE-C1 (4.42±0.56); SE-C2 (3.27±0.30). In the comparison between the adhesive systems, they were significantly different for the conditions control and 0.10mg/mL. For each adhesive systems, there was no difference between the different conditions according to the addition of rhodamine B. Regarding the shown results, addition of rodhamine B in non-simplified adhesives MP and SE, in the concentrations of 0.02mg/mL e 0.10mg/mL must be carefully added to avoid implications to the mechanical properties of the materials.
39

Comparação de diferentes pré-tratamentos de superfície na remineralização de esmalte com flúor em tratamento de lesões com mancha branca e sua resistência após desafio ácido / Comparison of different pretreatments on remineralization of enamel white spot lesions with fluoride and its resistance after new acidic challenge

Diana Ferreira Gadêlha de Araújo 03 June 2016 (has links)
A aplicação de flúor tópico é a principal estratégia de natureza química para a remineralização de lesões incipientes (LI) clinicamente visíveis como manchas brancas (MB) por cárie. Abordagens para aumentar a retenção de F no substrato pode favorecer sua ação e para isso, tratamentos prévios da superfície do esmalte podem ser usados. O objetivo deste trabalho foi comparar a capacidade de remineralização do flúor sem e com pré-tratamento do esmalte com ácido fosfórico e nitrato de alumínio e a sua resistência após novo desafio. Sessenta espécimes de esmalte bovino foram preparados (6mm x 4mm) e selecionados por meio de análise de microdureza de superfície (MS). LI foram produzidas através de ciclagem Desmineralização-Remineralização (DES-RE) e os espécimes divididos aleatoriamente em cinco grupos, de acordo com o tratamento (n=12): V- controle (verniz de fluoreto de sódio 5% por 4 horas), F (sem pré-tratamento); P-F(condicionamento ácido com ácido fosfórico por 30s); Al-F (nitrato de alumínio a 0,05M por 1min); P-Al-F (condicionamento com ácido fosfórico a 37% + nitrato de alumínio a 0,05M). Os tratamentos foram repetidos semanalmente durante quatro semanas. Após o tratamento, os espécimes foram submetidos à nova ciclagem ácida. Após cada etapa, nova MS foi realizada e ao final das análises, um corte transversal dos espécimes foi realizado. Uma das metades foi submetida à análise da microdureza longitudinal (ML) e a outra preparada para realização da microrradiografia transversal (TMR) para a análise de conteúdo mineral perdido. O percentual de perda de dureza de superfície (%PDS) foi analisado por ANOVA a 2 critérios de medidas repetidas e Tukey e o percentual de perda de dureza longitudinal (%PDL) por ANOVA a 3 critérios de medidas repetidas e Tukey (p<0,05). Os dados de TMR no parâmetro LD (profundidade da lesão) foram analisados por ANOVA a dois critérios (p<0,05). Os resultados mostraram que a ciclagem DES-RE resultou em significante %PDS e %PDL em todos os grupos. Grupo F revelou menor perda de MS após tratamento e, F, Al-F e P-Al-F, mostraram menor perda de dureza final, após o novo desafio ácido. Na análise de %PDL, o grupo V apresentou menor perda de dureza final quando comparado com os demais grupos, nas diferentes profundidades. A análise do conteúdo mineral não revelou nenhuma diferença entre os tratamentos e fases. Nenhum dos pré tratamentos propostos foram capazes de otimizar a atuação do gel APF na remineralização de MB. / The topical fluoride is the main chemical strategy to remineralize incipient caries lesions (ICL) visible as carious white spot lesions (WSL). Approaches to increase the fluoride retention may favor its action and therefore, enamel pretreatments can be used for this purpose. The aim of this study was to compare the potential of fluoride remineralization with and without previous enamel pretreatment with aluminum nitrate and phosphoric acid as well as their resistance after a new acid challenge. Sixty bovine enamel specimens were prepared (6mm x 4mm) and selected by the surface hardness (SH) analysis. The ICL were produced using DE-RE cycling and the specimens were randomized in five groups, according to the treatment (n=12): Vcontrol (5% sodium fluoride varnish during 4h), and four groups previously preatreated with topical application of acidulated phosphate fluoride (APF) during 4min: F (without pretreatment), P-F (phosphoric acid etching during 30s), Al-F (0.05M aluminum nitrate during 1min); P-Al-F (phosphoric acid etching + aluminum nitrate). The treatments were performed weekly during four weeks. After the treatment, the specimens were submitted to the new acid challenge. After each step, a new SH analysis was performed followed by the transversal cut of the specimens. A half was submitted to the longitudinal cross-sectional hardness analysis (LH) and the other half was prepared to transverse microradiography assessments (TMR) to determine the loss of mineral content. The percentage of surface mineral loss (%SH) was analyzed using two-way repeated-measures ANOVA and the percentage of crosssectional mineral loss (%LH) by the three-way repeated-measures ANOVA and Tukey (p<0.05). Data of TMR analysis by LD (lesion depth) parameter was analyzed with two-way ANOVA (p<0.05). The results showed significant %SH and %LH after DE-RE cycling for all groups. F group showed the lowest %SH after treatment, with no significant difference to Al-F and P-Al-F after the new acid challenge. V group showed the lowest %LH compared to the other groups, in the different depths, suggesting more resistance. Mineral content assessment did not reveal any difference among treatments and phases. None pretreatments were able to increase the potential of fluoride remineralization.
40

Análise da qualidade da polimerização e da degradação de cimentos resinosos utilizados na cimentação de pinos de fibra de vidro por meio de testes de microdureza / Microhardness analysis of the polymerization quality and degradation of resin cements used for fiber posts cementation

Ana Paula Ribeiro do Vale Pedreira 16 April 2007 (has links)
Os cimentos resinosos têm sido largamente utilizados em odontologia restauradora com a finalidade de reter o pino intra-radicular e dissipar tensões entre este e a raiz. Entretanto, o grau de conversão alcançado pelos mesmos influencia suas propriedades mecânicas, biocompatibilidade e degradação pela água e pelos ácidos bucais. Testes de microdureza podem ser aplicados para estimar o grau de conversão de compósitos, uma vez que apresentam boa correlação com a espectroscopia infravermelha. Este trabalho objetivou analisar a microdureza de quatro cimentos resinosos de polimerização dual utilizados na cimentação de pinos de fibra de vidro, nos períodos inicial, após 24 horas de imersão em etanol a 75% e após 3 meses de armazenamento em água, e testar a hipótese de que não há diferença entre a microdureza dos terços cervical, médio e apical na linha de cimento. Quarenta incisivos bovinos tratados endodonticamente foram distribuídos em quatro grupos para a cimentação de pinos Fibrekor® (Jeneric/Pentron) de 1mm de diâmetro, sendo: Grupo 1 - Panavia F 2.0 (Kuraray Medical Inc.), Grupo 2 - Variolink (Ivoclar), Grupo 3 - Rely X Unicem (3M ESPE) e Grupo 4 - Duolink (Bisco). Após a cimentação, as raízes foram divididas em 2 subgrupos, sendo 5 seccionadas após 7 dias para análise da microdureza inicial e 5 mantidas íntegras em água deionizada por 3 meses, para avaliação da microdureza final no microdurômetro Shimadzu HMV (Japan). Após a mensuração inicial, as raízes seccionadas eram armazenadas a 37º C por 24h em 10mL de solução de etanol a 75%, e reavaliadas. Foram identificadas diferenças estatisticamente significativas entre cimentos, terços e períodos (inicial ou após 24h de imersão em etanol a 75%), bem como interações entre cimento/terços e cimento/períodos de avaliação. O cimento Panavia exibiu os valores de microdureza inicial significativamente superiores, sem diferença estatística entre os demais cimentos. Os valores de microdureza inicial por terços não seguiram um padrão homogêneo; os cimentos Variolink e Duolink exibiram valores de microdureza significativamente superiores no terço cervical, sem diferença significativa entre os terços para os demais cimentos. A imersão em etanol reduziu significativamente a média dos valores de dureza para todos os cimentos; o comportamento por terços variou em função do material. O armazenamento em água por 3 meses não exerceu influência sobre a dureza da maioria dos cimentos, com exceção do Unicem, que exibiu aumento significativo dos valores de dureza após esse período. Portanto, a hipótese proposta neste estudo foi rejeitada. / Resin cements have been largely used in dentistry for retaining intraradicular posts and to minimize tension between them. However, the degree of conversion influences mechanical properties, biocompatibility and susceptibility of water and acid degradation of these polymers. Hardness tests are used to estimate the degree of conversion of composites, as it shows good correlation with infrared spectroscopy. The aim of this study was to evaluate the microhardness of four resin cements used for fiber posts cementation at the nitial period, 24h-immersion in a 75% ethanol solution and after 3-month water storage. Forty bovine incisives were endodontically treated and restored with 1mm diameter Fibrekor® posts (Jeneric/Pentron), being: Group 1 - Panavia F 2.0 (Kuraray Medical Inc.), Group 2 - Variolink (Ivoclar), Group 3 - Rely X Unicem (3M ESPE) and Group 4 - Duolink (Bisco). After cementation, each group was divided in two subgroups: 5 roots were sectioned 7 days after cementation for initial hardness measurement and 5 roots were immersed in deionized water for 3 months for final hardness measurements using Shimadzu Micro Hardness Tester (HMV, Japan). After the initial measurements, the sectioned roots were immersed in 10mL 75% ethanol solution for 24h at 37ºC, and tested again. Differences in hardness values have been detected among resin cements, radicular thirds and periods (initial or 24h-immersion in a 75% ethanol solution). Data also revealed significant interaction to cement/third and cement/period of evaluation. Panavia showed higher hardness values, with no statistical differences among the other cements. It was not verified a homogeneous pattern regarding radicular third; Variolink and Duolink exhibited higher hardness values for the cervical third, without differences among radicular thirds for the other cements. Hardness values decreased after ethanol immersion for all resin cements and the hardness according to radicular thirds varied among the materials. The hardness of tested resin cement showed no influence after 3-month water storage, except for Unicem as it showed an increase in Knoop hardness after this period. Therefore, the null hypotesis proposed was rejected.

Page generated in 0.0847 seconds