• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Programa de avaliação externa para os testes de triagem sorológica de doadores de bancos de sangue dos centros de referência da América Latina: utilização de multipainel específico / Externai evaluation program for blood donors infectious screening tests at Latin America reference centers: specific Multipanel use

Otani, Márcia Mitiko 04 September 2003 (has links)
Introdução: O risco de transmissão de agentes infeciosos por transfusão sangüínea é maior nos países em desenvolvimento. A hemoterapia na América Latina, embora tenha conquistado grandes avanços tecnológicos e políticos nos últimos anos, ainda apresenta diversos problemas que comprometem a qualidade dos resultados dos testes de triagem sorológica de doadores. A confiabilidade dos resultados emitidos pelos laboratórios que realizam testes de triagem sorológica de bancos de sangue pode ser determinada através de programas de avaliação externa, utilizando multipainéis específicos. Objetivos: Objetivou-se produzir multipainéis específicos para programas de avaliação externa em testes de triagem sorológica de bancos de sangue e determinar a qualidade dos resultados obtidos em 21 centros de referência da América Latina. Resultados: A seleção criteriosa da matéria-prima e a caracterização das amostras foram etapas importantes na determinação das características dos soros que constituíram os Multipainéis. Foram analisados os resultados de 5 programas, realizados no período de 1997 a 2000. A média da taxa de resultados falso-negativos (RFN) foi de 0,7% para anti-HIV, 2,89% para HBsAg, 4% para anti-H Bc, 10,7% para anti-HTLVI/II, 1,07% para anti-HCV, 3,22% para doença de Chagas e 6,25% para Sífilis. A média da taxa de resultados falsopositivos (RFP) variou de 0,73% para doença de Chagas a 5,28 % para antiHCV. Os resultados foram analisados sob diversos prismas, o desempenho de cada centro de referência, a concordância nos resultados das amostras, os \"kits\" utilizados e os parâmetros. Conclusão: Um programa sistemático como o aqui apresentado mostrou pontos importantes dentro do processo de triagem sorológica e auxiliou a elucidar algumas causas de erros. Houve uma melhora gradativa na qualidade dos resultados obtidos nos programas, do ano de 1997 para 1999. Quanto maior a proporção de amostras positivas, maior é a chance de laboratórios cometerem erros, como foi observado no multipainel do quinto programa, que teve aumento da taxa de RFN e RFP, evidenciando a existência de falhas no processo. A participação contínua nesses programas pareceu ser importante para o monitoramento das atividades realizadas no processo de triagem sorológica de doadores. / Background: In developing countries, the risk of acquiring infectious disease through blood transfusion is higher than developed countries. Although in the last 10 years, blood safety has improved in Latin America in terms of technology and politics, several problems remained unsolved that compromise the quality of the results obtained by the laboratories that perform infectious diseases screening tests. Externai evaluation program, using specific multipanel, may be an important tool to evaluate a laboratory that perform serological screening tests. Externai quality control program for blood bank serological test had not been previously performed in Latin America. Objectives: To develop the technology to produce panel of sera reactive to blood born infectious diseases and to determine the quality of the results of 21 reference centers of Latin America. Results: The criteria to select the raw material and to characterize the sample were important to determine the overall quality of the pane!. Using the Multipanel, tive Externai Quality Control programs were organized during 1997 to 2000 with 21 reference laboratories in 16 countries in Latin America. The mean rate of the false negative results was 0,7% for ant-HIV test, 2.89% for HBsAg, 4% for ant-HBc, 10.7% for ant-HTLVI/II, 1.07% for ant-HCV, 3.22% for Chagas diseases, and 6.25% for Syphilis. The mean rate of false positive results varied from 0.73% for Chagas diseases to 5.28% to ant-HCV. The results were also analyzed in terms of performance of each reference center and by the manufacture of the kits used. Conclusion: The program could provide clues about sources of common errors and was an important tool to validate the laboratory screening processo The quality of the results improved from the 1 st to the 4th programo The chance of doing errors was higher, when the proportion of positive samples were higher, as observed in the 5th program that registered elevated index of false positive and false negative results. The continuing participation in this kind of program seemed to be important to monitor the activities performed by the blood bank screening laboratory.
2

Programa de avaliação externa para os testes de triagem sorológica de doadores de bancos de sangue dos centros de referência da América Latina: utilização de multipainel específico / Externai evaluation program for blood donors infectious screening tests at Latin America reference centers: specific Multipanel use

Márcia Mitiko Otani 04 September 2003 (has links)
Introdução: O risco de transmissão de agentes infeciosos por transfusão sangüínea é maior nos países em desenvolvimento. A hemoterapia na América Latina, embora tenha conquistado grandes avanços tecnológicos e políticos nos últimos anos, ainda apresenta diversos problemas que comprometem a qualidade dos resultados dos testes de triagem sorológica de doadores. A confiabilidade dos resultados emitidos pelos laboratórios que realizam testes de triagem sorológica de bancos de sangue pode ser determinada através de programas de avaliação externa, utilizando multipainéis específicos. Objetivos: Objetivou-se produzir multipainéis específicos para programas de avaliação externa em testes de triagem sorológica de bancos de sangue e determinar a qualidade dos resultados obtidos em 21 centros de referência da América Latina. Resultados: A seleção criteriosa da matéria-prima e a caracterização das amostras foram etapas importantes na determinação das características dos soros que constituíram os Multipainéis. Foram analisados os resultados de 5 programas, realizados no período de 1997 a 2000. A média da taxa de resultados falso-negativos (RFN) foi de 0,7% para anti-HIV, 2,89% para HBsAg, 4% para anti-H Bc, 10,7% para anti-HTLVI/II, 1,07% para anti-HCV, 3,22% para doença de Chagas e 6,25% para Sífilis. A média da taxa de resultados falsopositivos (RFP) variou de 0,73% para doença de Chagas a 5,28 % para antiHCV. Os resultados foram analisados sob diversos prismas, o desempenho de cada centro de referência, a concordância nos resultados das amostras, os \"kits\" utilizados e os parâmetros. Conclusão: Um programa sistemático como o aqui apresentado mostrou pontos importantes dentro do processo de triagem sorológica e auxiliou a elucidar algumas causas de erros. Houve uma melhora gradativa na qualidade dos resultados obtidos nos programas, do ano de 1997 para 1999. Quanto maior a proporção de amostras positivas, maior é a chance de laboratórios cometerem erros, como foi observado no multipainel do quinto programa, que teve aumento da taxa de RFN e RFP, evidenciando a existência de falhas no processo. A participação contínua nesses programas pareceu ser importante para o monitoramento das atividades realizadas no processo de triagem sorológica de doadores. / Background: In developing countries, the risk of acquiring infectious disease through blood transfusion is higher than developed countries. Although in the last 10 years, blood safety has improved in Latin America in terms of technology and politics, several problems remained unsolved that compromise the quality of the results obtained by the laboratories that perform infectious diseases screening tests. Externai evaluation program, using specific multipanel, may be an important tool to evaluate a laboratory that perform serological screening tests. Externai quality control program for blood bank serological test had not been previously performed in Latin America. Objectives: To develop the technology to produce panel of sera reactive to blood born infectious diseases and to determine the quality of the results of 21 reference centers of Latin America. Results: The criteria to select the raw material and to characterize the sample were important to determine the overall quality of the pane!. Using the Multipanel, tive Externai Quality Control programs were organized during 1997 to 2000 with 21 reference laboratories in 16 countries in Latin America. The mean rate of the false negative results was 0,7% for ant-HIV test, 2.89% for HBsAg, 4% for ant-HBc, 10.7% for ant-HTLVI/II, 1.07% for ant-HCV, 3.22% for Chagas diseases, and 6.25% for Syphilis. The mean rate of false positive results varied from 0.73% for Chagas diseases to 5.28% to ant-HCV. The results were also analyzed in terms of performance of each reference center and by the manufacture of the kits used. Conclusion: The program could provide clues about sources of common errors and was an important tool to validate the laboratory screening processo The quality of the results improved from the 1 st to the 4th programo The chance of doing errors was higher, when the proportion of positive samples were higher, as observed in the 5th program that registered elevated index of false positive and false negative results. The continuing participation in this kind of program seemed to be important to monitor the activities performed by the blood bank screening laboratory.
3

Avaliação de diferentes metodologias laboratoriais para detecção de aloanticorpos plaquetários. Determinação da prevalência e importância clínica destes aloanticorpos em pacientes transfundidos / Evaluation of different methodologies for platelet alloantibodies detection. Clinical impact and prevalence of platelet antibodies in transfused patients.

Wendel, Rita de Cassia Legaspe Fontao 08 April 2008 (has links)
A aloimunização contra antígenos plaquetários é um dos grandes desafios no tratamento de pacientes refratários à transfusão de plaquetas. OBJETIVOS: avaliar o desempenho de metodologias mais utilizadas em laboratórios de referência internacional para a pesquisa de anticorpos plaquetários (PAP); verificar a prevalência destes anticorpos na nossa população; avaliar se as transfusões estão causando aloimunização, e se estes aloanticorpos apresentam importância clínica. MATERIAIS E MÉTODOS: foram testadas amostras PRÉ e PÓS transfusionais em três grupos de pacientes sendo grupo 1 com patologias onco-hematológicas, grupo 2 com patologias não tumorais e grupo 3 composto dos mesmos tipos de pacientes do grupo 2 mas que não receberam transfusão (grupo controle). Numa primeira fase foi realizado estudo retrospectivo com amostras de soro congeladas no período de 1996 a 2001. A segunda fase consistiu em estudo prospectivo com amostras coletadas dos pacientes durante sua internação, no período de 2004 a 2006. Quatro diferentes metodologias foram testadas: imunofluorescência indireta por citometria de fluxo (PIFT), imobilização de antígenos plaquetários utilizando anticorpos monoclonais (MAIPA), teste de microlinfocitotoxicidade (LCT) e uma nova metodologia, conhecida como FLOW PRA&#8482;. Na fase 1 foram analisados 87 pacientes, e na fase 2, 96 pacientes, separados nos três grupos respectivamente. Na segunda fase do estudo, foi realizado o incremento da contagem corrigida de plaquetas (ICCp) para todos os pacientes que receberam transfusão de plaquetas. Para esta avaliação um novo grupo de pacientes (n=40) foi adicionado ao estudo, devido ao pequeno número encontrado na segunda fase. RESULTADOS: as metodologias testadas apresentaram diferenças nas freqüências dos anticorpos detectados, porém as metodologias MAIPA, PIFT e FLOW PRA&#8482; foram as mais concordantes entre si. A qualidade dos soros utilizados na fase 1 afetou os resultados encontrados devido ao seu prolongado tempo de armazenamento. Porém, este fato foi eliminado na fase 2, quando foram utilizados soros mais recentes. A prevalência de anticorpos encontrada foi de 22,6% nos pacientes do grupo 1 e 31,4% nos pacientes do grupo 2. Para o grupo 3 nenhum novo anticorpo foi detectado. A especificidade dos anticorpos encontrados foi na grande maioria HLA classe I (84%) seguido de anticorpos pan reativos com as glicoproteínas plaquetárias (8%) e anticorpos contra antígenos humanos plaquetários (HPA - 8%). A transfusão sangüínea apresentou associação significativa (p<0,05) com a presença de aloanticorpos somente nos pacientes do grupo 2. Os ICCp dos pacientes que apresentaram PAP reativa foram significantemente menores (p<0,05) que os ICCp dos pacientes que apresentaram PAP não reativas. Os pacientes com PAP reativas, ao receberam transfusões de plaquetas compatíveis passaram a apresentar ICCp semelhantes aos pacientes com PAP não reativa. Ao utilizar-se a refratariedade plaquetária como padrão-ouro para comparar as metodologias testadas verificou-se que não houve diferença entre as mesmas (p<0,05). CONCLUSÕES: A prevalência de anticorpos plaquetários é semelhante à encontrada na literatura. A transfusão estimulou a produção de anticorpos no grupo 2. Os anticorpos identificados apresentam importância clínica afetando o rendimento da transfusão de plaquetas. Devido a maior praticidade da técnica PIFT e dos bons resultados encontrados, sugerimos que esta deva ser utilizada como rotina para PAP em pacientes refratários. / The alloimmunization against platelet antigens is one of the great challenges in the treatment of platelet refractory patients. OBJECTIVES: To evaluate the performance of the most used methodologies for platelet antibodies screening (PAS); to verify the prevalence of these antibodies in our population; to evaluate if transfusions are causing alloimmunization, and if these alloantibodies present clinical importance. MATERIALS AND METHODS: samples were tested before and after transfusions in three groups of patients, Group 1 having onco-hematologic diseases, Group 2 having non-oncologic diseases, and Group 3 consisted of the same type of patients as Group 2 but had not received a transfusion (control group). In the first phase, a retrospective study was performed using frozen sera samples from 1996 to 2001. The second phase consisted of a prospective study with samples collected from patients during their internment, from 2004 to 2006. Four different methodologies were tested: the indirect Platelet Immunofluorescence Test (PIFT), the Monoclonal Antibody Immobilization of Platelet Antigen (MAIPA), the standard Lymphocytotoxicity Test (LCT) and a new methodology, known as FLOW PRA&#8482;. In Phase 1 87 patients were analyzed, and in Phase 2, 96 patients, separated into three groups respectively. In the second phase of the study, the Corrected Count Increment (CCI) was carried out for all patients who had received a platelet transfusion. For this evaluation a new group of patients (n=40) was added to the study, due to the low number found in the second phase. RESULTS: the methodologies presented differences in the frequencies of the detected antibodies; however MAIPA, PIFT and FLOW PRA&#8482; were the ones that were more concordant with each other. The quality of the sera used in Phase 1 affected the results due to long storage time. However, this event was eliminated in phase 2, when more recent sera were used. The prevalence of antibodies was 22.6% in the patients of Group 1 and 31.4% in the patients of Group 2. For Group 3 no new antibody was detected. The specificity of the antibodies was predominantly HLA class I antibodies (84%) followed by pan-reactive antibodies with platelet glycoproteins (8%) and antibodies against Human Platelet Antigen (HPA - 8%). Blood transfusion only presented a significant association (p<0.05) with the presence of alloantibodies in the patients of Group 2. The CCI of the patients who presented platelet antibodies was significantly less (p<0.05) that the CCI of the patients with non-antibodies. Patients with platelet antibodies, who received compatible platelet transfusions, showed similar CCI to the patients with non-reactive antibodies. There was no difference among the methodologies (p>0,05) to identify clinically significant antibodies. CONCLUSIONS: The prevalence of platelet antibodies is similar to that found in published literature. Transfusion stimulated the production of antibodies in group 2. The identified platelet antibodies present clinical importance affecting the efficiency of platelet transfusion. Due to the widespread use of the PIFT technique and the good results found, we suggest that this should be used as routine for PAP in refractory patients.
4

Avaliação de diferentes metodologias laboratoriais para detecção de aloanticorpos plaquetários. Determinação da prevalência e importância clínica destes aloanticorpos em pacientes transfundidos / Evaluation of different methodologies for platelet alloantibodies detection. Clinical impact and prevalence of platelet antibodies in transfused patients.

Rita de Cassia Legaspe Fontao Wendel 08 April 2008 (has links)
A aloimunização contra antígenos plaquetários é um dos grandes desafios no tratamento de pacientes refratários à transfusão de plaquetas. OBJETIVOS: avaliar o desempenho de metodologias mais utilizadas em laboratórios de referência internacional para a pesquisa de anticorpos plaquetários (PAP); verificar a prevalência destes anticorpos na nossa população; avaliar se as transfusões estão causando aloimunização, e se estes aloanticorpos apresentam importância clínica. MATERIAIS E MÉTODOS: foram testadas amostras PRÉ e PÓS transfusionais em três grupos de pacientes sendo grupo 1 com patologias onco-hematológicas, grupo 2 com patologias não tumorais e grupo 3 composto dos mesmos tipos de pacientes do grupo 2 mas que não receberam transfusão (grupo controle). Numa primeira fase foi realizado estudo retrospectivo com amostras de soro congeladas no período de 1996 a 2001. A segunda fase consistiu em estudo prospectivo com amostras coletadas dos pacientes durante sua internação, no período de 2004 a 2006. Quatro diferentes metodologias foram testadas: imunofluorescência indireta por citometria de fluxo (PIFT), imobilização de antígenos plaquetários utilizando anticorpos monoclonais (MAIPA), teste de microlinfocitotoxicidade (LCT) e uma nova metodologia, conhecida como FLOW PRA&#8482;. Na fase 1 foram analisados 87 pacientes, e na fase 2, 96 pacientes, separados nos três grupos respectivamente. Na segunda fase do estudo, foi realizado o incremento da contagem corrigida de plaquetas (ICCp) para todos os pacientes que receberam transfusão de plaquetas. Para esta avaliação um novo grupo de pacientes (n=40) foi adicionado ao estudo, devido ao pequeno número encontrado na segunda fase. RESULTADOS: as metodologias testadas apresentaram diferenças nas freqüências dos anticorpos detectados, porém as metodologias MAIPA, PIFT e FLOW PRA&#8482; foram as mais concordantes entre si. A qualidade dos soros utilizados na fase 1 afetou os resultados encontrados devido ao seu prolongado tempo de armazenamento. Porém, este fato foi eliminado na fase 2, quando foram utilizados soros mais recentes. A prevalência de anticorpos encontrada foi de 22,6% nos pacientes do grupo 1 e 31,4% nos pacientes do grupo 2. Para o grupo 3 nenhum novo anticorpo foi detectado. A especificidade dos anticorpos encontrados foi na grande maioria HLA classe I (84%) seguido de anticorpos pan reativos com as glicoproteínas plaquetárias (8%) e anticorpos contra antígenos humanos plaquetários (HPA - 8%). A transfusão sangüínea apresentou associação significativa (p<0,05) com a presença de aloanticorpos somente nos pacientes do grupo 2. Os ICCp dos pacientes que apresentaram PAP reativa foram significantemente menores (p<0,05) que os ICCp dos pacientes que apresentaram PAP não reativas. Os pacientes com PAP reativas, ao receberam transfusões de plaquetas compatíveis passaram a apresentar ICCp semelhantes aos pacientes com PAP não reativa. Ao utilizar-se a refratariedade plaquetária como padrão-ouro para comparar as metodologias testadas verificou-se que não houve diferença entre as mesmas (p<0,05). CONCLUSÕES: A prevalência de anticorpos plaquetários é semelhante à encontrada na literatura. A transfusão estimulou a produção de anticorpos no grupo 2. Os anticorpos identificados apresentam importância clínica afetando o rendimento da transfusão de plaquetas. Devido a maior praticidade da técnica PIFT e dos bons resultados encontrados, sugerimos que esta deva ser utilizada como rotina para PAP em pacientes refratários. / The alloimmunization against platelet antigens is one of the great challenges in the treatment of platelet refractory patients. OBJECTIVES: To evaluate the performance of the most used methodologies for platelet antibodies screening (PAS); to verify the prevalence of these antibodies in our population; to evaluate if transfusions are causing alloimmunization, and if these alloantibodies present clinical importance. MATERIALS AND METHODS: samples were tested before and after transfusions in three groups of patients, Group 1 having onco-hematologic diseases, Group 2 having non-oncologic diseases, and Group 3 consisted of the same type of patients as Group 2 but had not received a transfusion (control group). In the first phase, a retrospective study was performed using frozen sera samples from 1996 to 2001. The second phase consisted of a prospective study with samples collected from patients during their internment, from 2004 to 2006. Four different methodologies were tested: the indirect Platelet Immunofluorescence Test (PIFT), the Monoclonal Antibody Immobilization of Platelet Antigen (MAIPA), the standard Lymphocytotoxicity Test (LCT) and a new methodology, known as FLOW PRA&#8482;. In Phase 1 87 patients were analyzed, and in Phase 2, 96 patients, separated into three groups respectively. In the second phase of the study, the Corrected Count Increment (CCI) was carried out for all patients who had received a platelet transfusion. For this evaluation a new group of patients (n=40) was added to the study, due to the low number found in the second phase. RESULTS: the methodologies presented differences in the frequencies of the detected antibodies; however MAIPA, PIFT and FLOW PRA&#8482; were the ones that were more concordant with each other. The quality of the sera used in Phase 1 affected the results due to long storage time. However, this event was eliminated in phase 2, when more recent sera were used. The prevalence of antibodies was 22.6% in the patients of Group 1 and 31.4% in the patients of Group 2. For Group 3 no new antibody was detected. The specificity of the antibodies was predominantly HLA class I antibodies (84%) followed by pan-reactive antibodies with platelet glycoproteins (8%) and antibodies against Human Platelet Antigen (HPA - 8%). Blood transfusion only presented a significant association (p<0.05) with the presence of alloantibodies in the patients of Group 2. The CCI of the patients who presented platelet antibodies was significantly less (p<0.05) that the CCI of the patients with non-antibodies. Patients with platelet antibodies, who received compatible platelet transfusions, showed similar CCI to the patients with non-reactive antibodies. There was no difference among the methodologies (p>0,05) to identify clinically significant antibodies. CONCLUSIONS: The prevalence of platelet antibodies is similar to that found in published literature. Transfusion stimulated the production of antibodies in group 2. The identified platelet antibodies present clinical importance affecting the efficiency of platelet transfusion. Due to the widespread use of the PIFT technique and the good results found, we suggest that this should be used as routine for PAP in refractory patients.
5

Avaliação dos testes e algoritmos empregados na triagem de doadores de sangue para o vírus da hepatite C / Evaluation of anti-HCV and HCV RNA tests and analysis of algorithm for blood donors screening

Barreto, Angela Maria Egydio de Carvalho 08 December 2004 (has links)
O diagnóstico da infecção pelo vírus da hepatite C (HCV) é obtido através de testes de triagem para anti-HCV pelo ELISA e para confirmar os positivos, por teste suplementar mais específico, o immunoblot (IB). A infecção ativa é determinada pelas técnicas moleculares como por exemplo a PCR. Os testes sorológicos são métodos indiretos, baseados na detecção de anticorpos específicos, estando portanto, sujeito a vários fatores que limitam a sua eficiência diagnóstica, podendo gerar resultados inespecíficos. Um dos objetivos deste trabalho foi o de avaliar a eficiência diagnóstica dos testes para o diagnóstico da infecção pelo HCV, em condições de rotina diagnóstica, em um grande número de amostras de doadores de sangue e analisar o custo benefício de três diferentes algoritmos, recentemente propostos pelo Centro de Controle de Doenças e Prevenção (EUA). Foram estudadas 692 amostras de soros provenientes de doadores de sangue, sendo 522 positivas e 170 inconclusivas pelo ELISA de triagem (ELlSA-T) realizado no momento da doação. Esses doadores retornaram à Fundação PróSangue/ Hemocentro de São Paulo para a coleta da segunda amostra de sangue para confirmação dos resultados obtidos na doação. Em todas as amostras de retorno foram realizadas ELISA (ELISA-R) e a PCR, o IB somente nas positivas ou indeterminadas no ELISA-R. A concordância global de resultados entre ELlSA-T e ELlSA-R foi de 64,5%, sendo 77,6% (405/522) entre os positivos e 24,1 % (41/170) entre os inconclusivos. Em amostras positivas nos dois ELlSAs, o IB foi positivo (aqui denominadas de sorologicamente positivas) em 69,6% (282/405) e PCR em 61,2% (248/405). Entre as 282 amostras sorologicamente positivas, viremia foi detectada em 87,6% (247/282). A ausência de viremia em 12,4% (37/282) dessas amostras pode representar amostras de indivíduos que tiveram a infecção no passado e que eliminaram espontaneamente o HCV. A avaliação de bandas individuais no IB mostrou a alta freqüência das bandas do core (C1C2 e C3C4). Entretanto sua distribuição entre as amostras de doadores virêmicos e não virêmicos foi bastante semelhante. A intensidade da reação, expressa como graduação da coloração das bandas no IB, demonstrou que C1C2 e NS3 fortemente reativas eram as mais associadas à positividade no IB e na PCR e a banda NS4 somente com a PCR. A análise dos resultados do teste de ELISA anti-HCV de doadores de sangue indicou que a relação DO/CO, aqui denominada de índice de reatividade (IR), poderia ser utilizada como preditivo de positividade no teste suplementar. O IR de todas as amostras foram estratificados em 6 grupos sendo o IR &#8805; 6 o que melhor correlacionou-se com a positividade no IB (IR de corte). Os três algoritmos para o diagnóstico da infecção pelo HCV, propostos pelo CDC foram avaliados, sendo dois novos (a e b) e o outro, o algoritmo convencional (c). a) Resultados de ELISA com IR &#8805; 6,0 é considerado positivo sem a necessidade de teste suplementar. Para amostras IR < 6,0, de preferência o IB, seria realizado; b) Teste molecular (NAT) deve ser feito para todas as amostras positivas no teste de triagem, seguido de IB naquelas negativas no NAT; c) IB realizado para todas as amostras positivas na triagem. Esses algoritmos foram aplicados em todas as amostras, com resultados muito semelhantes entre si: 287, 287 e 285 positivos, respectivamente para a, b e c. Um total de 283 amostras foi positivo nos três algoritmos e quatro, com resultados divergentes, foram analisadas separadamente. A análise do custo benefício mostrou que o algoritmo a é o mais econômico e prático podendo ser recomendado para os laboratórios com condições econômicas limitadas; o b é o mais completo para fins de decisão médica, fornecendo informações precoces sobre a presença ou a ausência da viremia; o c é importante para determinar o status imunológico e para a população de baixa prevalência da infecção pelo HCV. O custo estimado dos três algoritmos baseou-se na tabela de 2004 da Associação Médica Brasileira. Esses custos mostraram ser o algoritmo a, 40% mais econômico e o b, 18,2% mais oneroso do que o c. Os algoritmos a e c foram complementados pela realização da PCR, nas amostras indeterminadas provenientes desses algoritmos. Duas amostras resultaram em PCR positivas, as mesmas já consideradas positivas inicialmente pelo algoritmo b. Os três algoritmos estudados, puderam ser validados para o diagnóstico laboratorial da infecção pelo HCV, podendo a escolha depender do interesse clínico ou da prevalência dessa infecção na população. / The diagnosis of hepatitis C (HCV) infection is usually undertaken stepwise by screening with ELISA and confirming the positive results in screening with a more specific assay, the immunoblot (IB). Active infection by hepatitis C virus should be confirmed by molecular techniques such as PCR. Serological tests are indirect methods based on specific antibody detection. Therefore, they may be influenced by many factors which limit their diagnostic efficiency, producing false-positive results. The aim of this work was to evaluate the real diagnostic efficiency of anti-HCV screening tests, in routine condition, in a large serum sampling, and to analyze the cost-benefit of three different algorithms recently proposed by the Center for Diseases Control and Prevention. 692 serum samples were studied. The samples consisted of 522 sera from blood donors, positive in ELISA, with the sample collected by the time of donation (ELlSA-T), and of 170 inconclusive sera. Those donors returned to Fundação PróSangue Hemocentro de São Paulo to have a second sample of blood collected to confirm the former results. ELlSA-R and PCR were carried out in all second samples and all the positive and inconclusive samples were submitted to IB. The global concordance of results between ELlSA-T and ELlSA-R was 64,5%, in that 77,6%(405/522) were obtained among the positives results and 24,1% (41/170) among inconclusive. For samples positive in both ELlSAs, IB was positive (serologically positive) in 69,6% (282/405) and PCR in 61,2% (248/405). Among 282 serologically positive samples, viremia was detected in 87,6% (247/282) and it was absent in 12,4% (37/282) of the sera, which could represent samples from individuals who were infected by HCV in the past and who have spontaneously cleared the virus. Evaluation of each antigenic band of IB showed high frequency of core (C1C2 and C3C4). Their distribution among viremic and non-viremic donors was similar. The reaction intensity, expressed by the color score of the bands, demonstrated that the strongly reactive bands of C1C2 and NS3 were associated with positiveness in IB and PCR and of NS4 only with PCR positive. Analysis of anti-HCV ELISA results from blood donors indicated that the signal-to-cut-off ratio (DO/CO), named as reactive index (IR) in this study, could be used to predict supplemental test positive results for anti-HCV. IR from all samples was classified in 6 groups, being IR &#8805; 6, the index better correlated with positive on IB (cut-off IR). The CDC has recently proposed three algorithms for HCV diagnosis, in which two were new (a and c) and one was a conventional algorithm (c). a) screening-test-positive samples with IR &#8805; 6,0 can be reported as anti-HCV positive without supplemental testing. IR < 6,0 should have refiex supplemental testing performed, preferably IB; b) reflex supplemental testing in all specimens screening-test-positive by performing NAT followed by IB for specimens with NAT negative results; c) reflex supplemental testing (IB) in all specimens screening-test-positive. These algorithms were applied to all samples and resulted in very similar positive results: 287, 287 and 285, respectively for a, b and c. A total of 283 samples were positive in three algorithms. Four samples showed divergent results and were analyzed separately. Cost-benefit - The algorithm a is the most economical and practical and it could be recommended for laboratory with limited conditions and for population with a high prevalence of HCV infection; b is the most complete for medical decision providing early information about the presence or absence of viremia; c is suitable for determining immune status and for HCV infection low prevalence population. The cost of the three algorithms was estimated based on the 2004 Brazilian Medical Association Table. These costs were 40% lower than c for algorithm a, and 18,2% higher for b. The algorithm a and c were complemented by performing PCR to solve indeterminate results. This complementary test detected two samples PCR positive which were already positive by algorithm b. Therefore we could validate those algorithms for HCV infection laboratory diagnosis. Laboratories and blood banks may choose the algorithm depending on the clinical interest or on the prevalence of HCV infection in the population.
6

Avaliação dos testes e algoritmos empregados na triagem de doadores de sangue para o vírus da hepatite C / Evaluation of anti-HCV and HCV RNA tests and analysis of algorithm for blood donors screening

Angela Maria Egydio de Carvalho Barreto 08 December 2004 (has links)
O diagnóstico da infecção pelo vírus da hepatite C (HCV) é obtido através de testes de triagem para anti-HCV pelo ELISA e para confirmar os positivos, por teste suplementar mais específico, o immunoblot (IB). A infecção ativa é determinada pelas técnicas moleculares como por exemplo a PCR. Os testes sorológicos são métodos indiretos, baseados na detecção de anticorpos específicos, estando portanto, sujeito a vários fatores que limitam a sua eficiência diagnóstica, podendo gerar resultados inespecíficos. Um dos objetivos deste trabalho foi o de avaliar a eficiência diagnóstica dos testes para o diagnóstico da infecção pelo HCV, em condições de rotina diagnóstica, em um grande número de amostras de doadores de sangue e analisar o custo benefício de três diferentes algoritmos, recentemente propostos pelo Centro de Controle de Doenças e Prevenção (EUA). Foram estudadas 692 amostras de soros provenientes de doadores de sangue, sendo 522 positivas e 170 inconclusivas pelo ELISA de triagem (ELlSA-T) realizado no momento da doação. Esses doadores retornaram à Fundação PróSangue/ Hemocentro de São Paulo para a coleta da segunda amostra de sangue para confirmação dos resultados obtidos na doação. Em todas as amostras de retorno foram realizadas ELISA (ELISA-R) e a PCR, o IB somente nas positivas ou indeterminadas no ELISA-R. A concordância global de resultados entre ELlSA-T e ELlSA-R foi de 64,5%, sendo 77,6% (405/522) entre os positivos e 24,1 % (41/170) entre os inconclusivos. Em amostras positivas nos dois ELlSAs, o IB foi positivo (aqui denominadas de sorologicamente positivas) em 69,6% (282/405) e PCR em 61,2% (248/405). Entre as 282 amostras sorologicamente positivas, viremia foi detectada em 87,6% (247/282). A ausência de viremia em 12,4% (37/282) dessas amostras pode representar amostras de indivíduos que tiveram a infecção no passado e que eliminaram espontaneamente o HCV. A avaliação de bandas individuais no IB mostrou a alta freqüência das bandas do core (C1C2 e C3C4). Entretanto sua distribuição entre as amostras de doadores virêmicos e não virêmicos foi bastante semelhante. A intensidade da reação, expressa como graduação da coloração das bandas no IB, demonstrou que C1C2 e NS3 fortemente reativas eram as mais associadas à positividade no IB e na PCR e a banda NS4 somente com a PCR. A análise dos resultados do teste de ELISA anti-HCV de doadores de sangue indicou que a relação DO/CO, aqui denominada de índice de reatividade (IR), poderia ser utilizada como preditivo de positividade no teste suplementar. O IR de todas as amostras foram estratificados em 6 grupos sendo o IR &#8805; 6 o que melhor correlacionou-se com a positividade no IB (IR de corte). Os três algoritmos para o diagnóstico da infecção pelo HCV, propostos pelo CDC foram avaliados, sendo dois novos (a e b) e o outro, o algoritmo convencional (c). a) Resultados de ELISA com IR &#8805; 6,0 é considerado positivo sem a necessidade de teste suplementar. Para amostras IR < 6,0, de preferência o IB, seria realizado; b) Teste molecular (NAT) deve ser feito para todas as amostras positivas no teste de triagem, seguido de IB naquelas negativas no NAT; c) IB realizado para todas as amostras positivas na triagem. Esses algoritmos foram aplicados em todas as amostras, com resultados muito semelhantes entre si: 287, 287 e 285 positivos, respectivamente para a, b e c. Um total de 283 amostras foi positivo nos três algoritmos e quatro, com resultados divergentes, foram analisadas separadamente. A análise do custo benefício mostrou que o algoritmo a é o mais econômico e prático podendo ser recomendado para os laboratórios com condições econômicas limitadas; o b é o mais completo para fins de decisão médica, fornecendo informações precoces sobre a presença ou a ausência da viremia; o c é importante para determinar o status imunológico e para a população de baixa prevalência da infecção pelo HCV. O custo estimado dos três algoritmos baseou-se na tabela de 2004 da Associação Médica Brasileira. Esses custos mostraram ser o algoritmo a, 40% mais econômico e o b, 18,2% mais oneroso do que o c. Os algoritmos a e c foram complementados pela realização da PCR, nas amostras indeterminadas provenientes desses algoritmos. Duas amostras resultaram em PCR positivas, as mesmas já consideradas positivas inicialmente pelo algoritmo b. Os três algoritmos estudados, puderam ser validados para o diagnóstico laboratorial da infecção pelo HCV, podendo a escolha depender do interesse clínico ou da prevalência dessa infecção na população. / The diagnosis of hepatitis C (HCV) infection is usually undertaken stepwise by screening with ELISA and confirming the positive results in screening with a more specific assay, the immunoblot (IB). Active infection by hepatitis C virus should be confirmed by molecular techniques such as PCR. Serological tests are indirect methods based on specific antibody detection. Therefore, they may be influenced by many factors which limit their diagnostic efficiency, producing false-positive results. The aim of this work was to evaluate the real diagnostic efficiency of anti-HCV screening tests, in routine condition, in a large serum sampling, and to analyze the cost-benefit of three different algorithms recently proposed by the Center for Diseases Control and Prevention. 692 serum samples were studied. The samples consisted of 522 sera from blood donors, positive in ELISA, with the sample collected by the time of donation (ELlSA-T), and of 170 inconclusive sera. Those donors returned to Fundação PróSangue Hemocentro de São Paulo to have a second sample of blood collected to confirm the former results. ELlSA-R and PCR were carried out in all second samples and all the positive and inconclusive samples were submitted to IB. The global concordance of results between ELlSA-T and ELlSA-R was 64,5%, in that 77,6%(405/522) were obtained among the positives results and 24,1% (41/170) among inconclusive. For samples positive in both ELlSAs, IB was positive (serologically positive) in 69,6% (282/405) and PCR in 61,2% (248/405). Among 282 serologically positive samples, viremia was detected in 87,6% (247/282) and it was absent in 12,4% (37/282) of the sera, which could represent samples from individuals who were infected by HCV in the past and who have spontaneously cleared the virus. Evaluation of each antigenic band of IB showed high frequency of core (C1C2 and C3C4). Their distribution among viremic and non-viremic donors was similar. The reaction intensity, expressed by the color score of the bands, demonstrated that the strongly reactive bands of C1C2 and NS3 were associated with positiveness in IB and PCR and of NS4 only with PCR positive. Analysis of anti-HCV ELISA results from blood donors indicated that the signal-to-cut-off ratio (DO/CO), named as reactive index (IR) in this study, could be used to predict supplemental test positive results for anti-HCV. IR from all samples was classified in 6 groups, being IR &#8805; 6, the index better correlated with positive on IB (cut-off IR). The CDC has recently proposed three algorithms for HCV diagnosis, in which two were new (a and c) and one was a conventional algorithm (c). a) screening-test-positive samples with IR &#8805; 6,0 can be reported as anti-HCV positive without supplemental testing. IR < 6,0 should have refiex supplemental testing performed, preferably IB; b) reflex supplemental testing in all specimens screening-test-positive by performing NAT followed by IB for specimens with NAT negative results; c) reflex supplemental testing (IB) in all specimens screening-test-positive. These algorithms were applied to all samples and resulted in very similar positive results: 287, 287 and 285, respectively for a, b and c. A total of 283 samples were positive in three algorithms. Four samples showed divergent results and were analyzed separately. Cost-benefit - The algorithm a is the most economical and practical and it could be recommended for laboratory with limited conditions and for population with a high prevalence of HCV infection; b is the most complete for medical decision providing early information about the presence or absence of viremia; c is suitable for determining immune status and for HCV infection low prevalence population. The cost of the three algorithms was estimated based on the 2004 Brazilian Medical Association Table. These costs were 40% lower than c for algorithm a, and 18,2% higher for b. The algorithm a and c were complemented by performing PCR to solve indeterminate results. This complementary test detected two samples PCR positive which were already positive by algorithm b. Therefore we could validate those algorithms for HCV infection laboratory diagnosis. Laboratories and blood banks may choose the algorithm depending on the clinical interest or on the prevalence of HCV infection in the population.

Page generated in 0.0818 seconds