• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 307
  • 107
  • 34
  • 21
  • 20
  • 10
  • 8
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 583
  • 583
  • 315
  • 294
  • 125
  • 89
  • 80
  • 76
  • 70
  • 68
  • 64
  • 64
  • 60
  • 58
  • 54
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Soluções projetuais de fachadas para edifícios de escritórios com ventilação natural em São Paulo / Facades design solutions for office buildings with natural ventilation in São Paulo

Marcondes, Mônica Pereira 07 June 2010 (has links)
A pesquisa parte da hipótese de que, sob as condições climáticas da cidade de São Paulo, a solução de fachada de um edifício de escritórios, com projeto arquitetônico aprimorado para o desempenho térmico com ventilação natural e uso eficiente (carga térmica interna de 32W/m2), proporciona condições de conforto térmico nos ambientes de trabalho por no mínimo 80% das horas ocupadas do ano sem uso de condicionamento artificial. O objetivo geral é a identificação de soluções projetuais de fachada para edifícios de escritórios com ventilação natural em São Paulo com programa de necessidades, projeto arquitetônico e implantação definidos, tendo em vista o aprimoramento do desempenho térmico do edifício para o conforto térmico dos ocupantes. Levantou-se exemplos de edifícios de escritórios recentes que aclamam ser térmica e energeticamente eficientes para seus contextos, e métodos de avaliação de desempenho térmico e energético de fachadas e de edifícios de escritórios, com destaque para a ventilação natural. Com base em dois modelos de edifício de referência elaborados, sessenta e quatro cenários de edifícios de escritórios com diferentes configurações e condições de ventilação foram avaliados com simulação térmica anual, considerando o clima de São Paulo. Para cada cenário de edifício estabeleceu-se uma relação, adequada às condições desejáveis de conforto térmico dos usuários, entre uma vazão de ar de referência e o ganho máximo de calor no ambiente através da fachada. Os resultados das simulações deram subsídios para o projeto de soluções possíveis de fachadas para os vinte e três casos de edifícios de escritórios que apresentaram no mínimo 80% das horas ocupadas no ano em conforto. Os produtos finais da tese são: (I) dois modelos de edifício de escritórios de referência, com características arquitetônicas e parâmetros de ocupação aprimorados para o desempenho térmico da edificação com ventilação natural sob o clima de São Paulo; (II) método de avaliação de desempenho térmico de edifícios de escritórios com ventilação natural; (III) procedimento para o dimensionamento de soluções de fachada para edifícios de escritórios com ventilação natural; (IV) soluções projetuais de fachada para edifícios de escritórios com ventilação natural e desempenho térmico aprimorado. / The research starts from the hypothesis that, under the climatic conditions of the city of São Paulo, the facades solution of an office building, with an improved architectural design for thermal performance with natural ventilation and an efficient use (internal thermal load of 32W/m2), provides thermal comfort conditions at the work spaces for at least 80% of the occupied hours during the year without use of artificial air conditioning. The main objective is to identify facades design solutions for office buildings with natural ventilation in São Paulo with program of activities, architectural design and site plan defined, considering the improvement of the thermal performance of the building for occupant thermal comfort. Recent examples of office buildings which claim to be thermal and energy efficient to their contexts, and methods of thermal and energy performance evaluation of facades and office buildings, with emphasis on natural ventilation, were listed. Based on two proposed reference models of buildings, sixty four scenarios of office buildings with different configurations and ventilation conditions were evaluated with thermodynamic simulations, considering the climate of São Paulo. For each scenario it was established a relationship, in accordance with users acceptable thermal comfort conditions, between a reference ventilation rate and the maximum heat gain in the office through the façade. The results of the simulations provided inputs for the design of possible facades solutions for twenty three cases of office buildings which presented at least 80% of the annual occupied hours in comfort. The final products of the thesis are: (I) two reference models of office buildings, with architectural design and occupational parameters enhanced for the building thermal performance with natural ventilation under the climatic conditions of São Paulo; (II) thermal performance evaluation method for office buildings with natural ventilation; (III) procedure for the design of facades solutions for office buildings with natural ventilation; (IV) facades design solutions for office buildings with natural ventilation and improved thermal performance.
252

Avaliação de tapete de borracha reciclável em piso de escamoteadores e sua influência no desenvolvimento e bem-estar de leitões na fase de maternidade / Evaluation of recyclable rubber in creep and its influence on the development and welfare of piglets in maternity

Possagnolo, Beatriz de Oliveira 26 June 2017 (has links)
Um dos grandes pilares para o sucesso da produtividade da produção de suínos é o aumento da taxa de leitões nascidos por matriz. Porém, para que esse resultado seja satisfatório, é necessário reduzir as taxas de mortalidade de leitões ao nascimento e aumentar o ganho de peso por leitegada. Nesse sentido, deve-se priorizar o bem-estar dos animais, reduzir os custos na produção e utilizar recursos favoráveis à sustentabilidade da produção. A borracha reciclável é um excelente recurso sustentável, podendo trazer benefícios para os leitões por ser um produto resistente, que absorve impacto e apresenta consistência macia, tornando o ambiente mais confortável, bom condutor térmico e antiderrapante. Esta pesquisa teve como objetivo avaliar a eficiência da cobertura do piso de escamoteadores com borracha reciclável com a utilização de dois diferentes tipos de tapete, em relação à utilização de piso convencional (piso de concreto coberto por maravalha), com o propósito de identificar a melhor adaptação dos leitões, observando o conforto térmico e consequentemente o desenvolvimento animal e aumento da produtividade. A pesquisa foi realizada no município de Mogi-Mirim/SP entre os meses de julho a agosto de 2015. Foram estabelecidos três tipos de tratamento: Tratamento 1 (T1) - piso coberto por maravalha; Tratamento 2 (T2) - piso coberto com tapete de borracha inteiriça; Tratamento 3 (T3) - piso coberto com tapete de borracha vazada, para 12 leitegadas (±50 animais/ tratamento). Os parâmetros analisados foram: comportamento e avaliação fisiológica avaliados em dias intercalados durante o experimento, em três períodos: manhã (H1 - 7:00h às 11:00h), tarde (H2 - 12:00h às 15:00h) e noite (H3 - 16:00h às 18:00h); e os índices zootécnicos e microclima das instalações avaliados diariamente. Utilizou-se o delineamento inteiramente casualizado (DIC) para as análises dos dados referentes à entalpia, ITU e comportamento; e delineamento em blocos casualiazados (DBC) referente aos dados das análises fisiológicas. As médias foram analisadas pelo teste de Tukey, a 5% de significância. A análise do microclima das instalações evidenciou estresse por frio constante, caracterizado pela entalpia abaixo de 68,40, porém dentro da faixa ideal dada pelo índice de temperatura e umidade (menor ou igual a 70). Os animais dos tratamentos com piso do escamoteador coberto por tapete de borra (vazado e inteiriço) mativeram-se por maior tempo, e expressaram uma maior quantidade de comportamentos dentro do escamoteador, quando evidencianda a escolha por um local de melhor conforto, em comparação ao tratamento convencional (maravalha). A utilização do tapete (inteiriço e vazado) influenciou de forma positiva, em melhorias na produção, ao que se refere ao índice de mortalidade por esmagamento. Este trabalho abre novas possibilidades de se avaliar a utilização de tapete de borracha reciclável na produção de suínos. Inaugura possibilidades de estudo de novos designs de tapete e de local de instalação, a fim de estabelecer um produto inovador e sustentável, tornando-o uma ferramenta rentável e eficientemente econômica na produção de suínos. / One of the great pillars for the swine production productive success is the increase in the rate of piglets by sow. However, for this result to be satisfactory it is necessary to reduce the piglet death rate at birth and increase the weight gain by litter. Hence, the animal welfare must be prioritized, the production costs reduced and favorable resources to the production sustainability used. The rubber is recyclable and it is an excellent sustainable resource that can benefit the piglets since it is a resistant material capable of absorbing impact, soft, able to make the environment more comfortable, good heat conductor and non-slip. The objective of this research is to evaluate the efficiency of covering the creep ground with recyclable rubber with the utilization of two different kinds of mats in relation to conventional ground (concrete covered by shavings), aiming to identify the best piglets adaptation taking in observation the thermal comfort, the animal development and increase in productivity. The research took place in the municipality of Mogi-Mirim/SP from July to August of 2015. Three treatments were established: Treatment 1 (T1) - ground covered by shavings; Treatment 2 (T2) - ground covered by rubber mat; Treatment 3 (T3) - ground covered by leaked rubber mat, for 12 litters (+-50 animals/treatment). The analyzed parameters were: behavior and physiological evaluation every other day during the experiment, in three periods: mornings (H1 - 7:00h to 11:00h), afternoon (H2 - 12:00h to 15:00h) and evening (H3 - 16:00h to 18:00h); and the zootechnical indices and the facilities microclimate evaluated daily. It was utilized a Completely Randomized Design (DIC) for the analyses of the enthalpy data, ITU and behavior; and Randomized-Completeblocks Design (DBC) for the physiological analysis. The averages were analysed by the Tuckey\'s test at 5% significance. The facilities microclimate analysis emphasized a constant cold stress, characterized by the enthalpy below 68,40, however, it falls in the ideal range given by the humidity and temperature index (less or equal to 70). The animals from the treatments with rubber mats maintained for a longer period of time and expressed a greater quantity inside of the creep, evidencing a choice for a place of better comfort, compared to the conventional treatment (shavings). The utilization of mats influenced in a positive way in the production when it comes to mortality by crushing. This study opens up new possibilities of evaluating the utilization of recyclable rubber in swine production. Inaugurate possibilities of studying new mat designs, placing in order to establish an innovative product, sustainable, making it a rentable tool, economically efficient in the swine production.
253

Respuesta térmica de edificaciones con envolventes vegetales: cubiertas verdes y fachadas verdes / Thermal response in buildings with green covers: green roofs and green facades

Pérez Gallardo, Nuria 16 March 2017 (has links)
El presente proyecto propuso un método experimental de medición de temperaturas internas con el fin de estudiar, comparar y entender la respuesta térmica frente al frío y al calor de cuatro células de ensayo denominadas Control (Sin vegetación) y tres células de ensayo con diferentes combinaciones de vegetación (cubiertas y fachadas) instaladas en una región de clima tropical. En ellas fueron medidas las temperaturas superficiales internas (TSI) y temperaturas del Bulbo Seco (TBS) mediante equipos específicos, un data logger, conectado a dos multiplicadores. Los datos fueron recogidos por un año y dentro de ese periodo fueron seleccionados los días críticos a estudiar. Varios datos climatológicos fueron considerados para abordar la influencia de las oscilaciones del tiempo meteorológico (episodios climáticos) en el ambiente interno construido, para lo cual fueron aplicados fundamentos de la Climatología Dinámica frente al comportamiento térmico de las células de ensayo. Los datos de las principales variables climáticas (radiación solar, humedad relativa y precipitación) fueron registradas en la Estación Meteorológica del CRHEA. Los resultados revelan que la célula de ensayo con vegetación en cubierta y fachadas, presenta más resistencia a las variaciones de temperaturas diarias, es decir, mejor comportamiento térmico, ya que muestra las menores amplitudes térmicas, los mayores retrasos térmicos, las menores temperaturas en días de calor extremo y las mayores en días de frío. Durante el día crítico de calor, las mayores diferencias entre las temperaturas máximas internas del aire, se presentan entre la célula construida con materiales convenciones y la célula que posee fachadas verdes y cubierta vegetal, de 2ºC y en torno a 3ºC en el caso de las temperaturas superficiales. Para el día crítico de frío, la diferencia entre ellas es de 1ºC para los valores de temperatura del aire, y de 2.2ºC para valores de temperaturas superficiales. Así, uso de vegetación en los edificios puede ser considerado una técnica capaz de mantener las condiciones internas más placenteras no solo en épocas calurosas, reduciendo la incidencia de la radiación solar directa, sino también en invierno, debido a su propiedad de aislante térmico que impide las rápidas pérdidas de calor, como ocurre en la célula sin vegetación. Los resultados obtenidos ponen de manifiesto que las hipótesis planteadas fueron alcanzadas, comprobando así, que el uso de vegetación combinado en fachadas y cubiertas contribuye a la mejora del comportamiento térmico, favoreciendo las condiciones térmicas internas en periodos de mayor o menor temperatura externa. / The present research proposed an experimental method for measuring internal temperatures of buildings, in order to study, compare, and understand the thermal response of four test cells against cold and heat, determined: control (without vegetation) and three test cells with different combinations of vegetation (on roofs and/or facades); installed in a tropical climate region. Internal surface temperatures (IST) and dry bulb temperatures (DBT) were measured using appropriate equipment, consisting of a data logger connected to two multipliers. Data were collected for one year and, during that period, the critical days that would be assessed were selected. Climatic data were considered in order to evaluate the influence of weather oscillations (climatic events) on the internal built environment, for which the principles of Dynamic Climatology were applied to understand the thermal behaviour of the test cells. The data obtained from the primary climatic variables (solar radiation, relative humidity, and precipitation) were recorded at the CRHEA. The results showed that the test cell with a green roof and green facades displayed higher resistance to changes in daily temperature, i.e., better thermal behavior, since it faced lower temperature intervals, higher thermal delays, lower temperatures on days of extreme heat, and higher temperatures on cold days. With respect to the critical heat day, the main differences between maximum internal air temperatures occurred between the cell constructed with conventional material and the cell that was built with green facades and a green roof, of 2°C in relation to the internal air temperature, and approximately 3°C with respect to surface temperatures. Regarding the critical cold day, the difference between test cells was of 1°C for air temperature values, and 2.2°C for surface temperature values. Therefore, the use of vegetation in construction can be considered a technique capable of maintaining the most pleasant indoor conditions, not only in hot climates, reducing the incidence of direct solar radiation, but also in the winter, due to thermal insulation properties that prevent the rapid loss of heat, which occurs in cells lacking vegetation. The obtained results show that the initial hypotheses were proven, thus confirming that the application of vegetation on facades and roofs contributes to the improvement of thermal performance, favoring internal thermal conditions during periods of higher or lower external temperatures.
254

Otimização de parâmetros de projeto de tubulações de sistemas de calefação por piso radiante. / Optimization of piping design parameters for a radiant floor heating system.

Díaz Rastello, María Carolina 02 September 2013 (has links)
Devido à climatização dos ambientes internos condicionar o bem estar e o conforto térmico das pessoas é que se fazem necessárias novas pesquisas que procurem potencializar as tecnologias existentes e reduzir tanto os custos de instalação quanto o consumo de energia. É sabido que os sistemas convencionais de calefação proporcionam um alto consumo de energia e uma emissão de níveis de ruído muitas vezes inaceitáveis, entretanto os sistemas radiantes ganham, a cada dia, uma maior abrangência como alternativa de climatização devido às suas vantagens comparativas com relação aos sistemas convencionais. O emprego de sistemas de calefação por piso radiante em muitos países é limitada pelo preço da instalação como consequência do elevado custo dos materiais como é o caso da fabricação das tubulações. Estas geralmente são fabricadas de polietileno ou de cobre, sendo este ultimo o que entrega um maior desempenho térmico e, por conseguinte um melhor fornecimento de energia, mas o elevado custo deste material restringe o seu uso principalmente ao setor residencial, podendo atingir um mercado maior que compreenda edifícios públicos, de escritório, escolas, hospitais, etc. Com isso, este trabalho procura reduzir a quantidade de materiais de tubulação necessários para garantir o desempenho do sistema e o conforto térmico de uma habitação aquecida com um sistema radiante. Para isto, foi desenvolvida a resolução numérica do modelo matemático da transferência de calor no interior do piso pelo método dos volumes finitos na formulação implícita e implementada em código computacional na linguagem Matlab. Para isto, foram considerados dois parâmetros fundamentais para garantir o conforto térmico da habitação que correspondem à temperatura da água e a distancia entre os tubos que compõem o sistema. A análise corresponde ao cálculo da temperatura superficial do piso para distintas temperaturas da água e distintas distâncias, obtendo resultados interessantes que permitem reduzir o custo da instalação em até um 40%. / Due to temperature control of interiors conditioning the well-being and the thermal comfort of people, it is necessary to make new researches aiming to improve the existing technologies and to reduce both installation costs and energy consumption. It is known that the use of traditional heating systems involves high energy consumption and, in some cases, unacceptable noise levels; while radiant systems are gaining a wider scope as a heating alternative due to its advantages compared to conventional systems. The use of radiant floor heating systems in Brazil is limited by installation cost due to the high price of required materials. This fact restricts the use of these systems primarily to the residential sector. However, it may be possible for this technology to reach a larger market, including public buildings, offices, schools and hospitals. Therefore, to optimize the most relevant design parameters relating to the thermal performance of the system and reduce both the amount of required materials and the system operating time, this paper elaborates on a method consisting of a high-resolution numerical mathematical model of the heat transfer within a floor using a finite control volume method with an implicit solution scheme. In this work, we consider how the properties of the materials, environmental thermal comfort factors and the performance of the system work together with the theoretical underpinnings of the heat transfer phenomenon to define the design parameters to optimize the materials and provide greater control over the energy consumption. This optimization is achieved without changing any environmental thermal comfort conditions or the well-being of the occupants. Finally, a numerical solution for the heat transfer within the floor is implemented using the computer code Matlab.
255

Indoor overheating risk : a framework for temporal building adaptation decision-making

Gichuyia, Linda Nkatha January 2017 (has links)
Overheating in buildings is predicted to increase as a result of a warming climate and urbanisation in most cities. With regards to responding to this challenge, decision makers ranging from_ design teams, local authorities, building users, national programs and market innovators; and during the different stages of a building’s service life, want to know a few pertinent matters: What space characteristics and buildings are at a higher risk and by how much?; What are the tradeoffs between alternative design and/or user-based actions?; What are the likely or possible consequences of their decisions?; What is the impact of climate change to indoor overheating?; among other decision support questions. However, such decision appraisal information still remains buried and dispersed in existing simulation models, and empirical studies, and not yet been clearly articulated in any existing study or model. Especially decision support information articulated in a way that gives each decision maker maximum capacity to anticipate and respond to thermal discomfort in different spaces and through the lifetime of a building. There is a need for an integrated and systematic means of building adaptation decision-support, which provides analytical leverage to these listed decision makers. A means that: 1) assimilates a range of indoor thermal comfort's causal and solution space processes; 2) reveals and enhances the exploration of the space and time-dependent patterns created by the dynamics of the indoor overheating phenomenon through time; and one that 3) imparts insight into decision strategy and its synthesis across multiple decision makers. This study recognises the lack of an overarching framework attending to the listed concerns. Therefore, the key aim of this thesis is to develop and test a building adaptation decision-support framework, which extends the scope of existing frameworks and indoor overheating risk models to facilitate trans-sectional evaluations that reveal temporal decision strategies. The generic framework frames a multi-method analysis aiming to underpin decision appraisal for different spaces over a 50 to 100-year time horizon. It constitutes an underlying architecture that engages the dimensions of decision support information generation, information structuring, its exploration and dissemination, to ease in drawing decision strategy flexibly and transparently. The multi-method framework brings together: 1) Systems thinking methods to a) facilitate the systematic exposure of the elements that shape indoor overheating risk, and b) reveal the processes that shape multi-stakeholder decision-making response over time; 2) The use of normative, predictive and exploratory building scenarios to a) examine the overheating phenomenon over time, and b) as a lens through which to explore the micro-dynamics brought about by aspects of heterogeneity and uncertainty; and 3) The application of both computational and optimization techniques to appraise potential routes towards indoor thermal comfort over an extended time scale by a) tracking shifts in frequency, intensity and distribution of indoor overheating vulnerability by causal elements over time and space; and b) tracking shifting optima of the heat mitigation solution space, with respect to time, climate futures, heterogeneity of spaces, and due to thermal comfort assumptions. The framework’s potential has been demonstrated through its application to office buildings in Nairobi.
256

Enjeux de la simulation pour l'étude des performances énergétiques des bâtiments en Afrique sub-saharienne / Challenges of simulation for buildings energy performance survey in Sub-Saharan Africa

Kaboré, Madi 27 January 2015 (has links)
Dans les pays de l’Afrique sub-saharienne, la situation énergétique, le fort taux d’accroissement des aires urbaines, l’inadaptation des techniques de construction et le climat offrent un grand potentiel pour la démarche bioclimatique et la construction durable notamment sur le plan énergétique. Cependant ce potentiel est faiblement exploré. Pour ce faire, cela passe par une bonne connaissance du comportement des bâtiments et par leur adaptation au contexte climatique. Dans le cadre de notre contribution à cette problématique, une étude sur le comportement thermique des bâtiments est initiée grâce à la simulation. En effet la simulation des performances énergétiques du bâtiment devient de plus en plus incontournable dans les processus de conception et d’analyse des bâtiments à travers le monde. Dans ce travail les outils de simulation des performances énergétiques ainsi que les outils d’optimisation sont utilisés pour mener des investigations sur un bâtiment type construit en matériaux conventionnels au Burkina Faso suivant deux principales approches. Dans la première approche le modèle numérique du bâtiment est confronté aux mesures issues de l’expérimentation sur le bâtiment réel. Une méthodologie de calibration basée sur l’analyse de sensibilité et l’optimisation des paramètres a été appliquée pour la comparaison des résultats. Cela a permis de caler le modèle et des études diagnostiques sont réalisées. Dans la seconde approche, des investigations sur des solutions d’amélioration des performances du bâtiment sont réalisées à travers l’application de la simulation dynamique comme outils d’aide à la conception. Les techniques d’interopérabilité et d’optimisation sont utilisées pour implémenter les solutions de refroidissement passif dont les impacts sur le bâtiment étudié sont évalués. Enfin dans ce travail, des techniques d’analyse du bâtiment et des critères de performance sont utilisées pour caractériser et formuler des recommandations sur la conception des bâtiments dans notre contexte climatique. / In sub-Saharan African countries, the energy context, the high urban growth, inadequate construction techniques and climate offer great potential for bio-climatic approach and sustainable construction particularly on the energy level. However, this potential and the use of passive cooling techniques are weakly explored. To do so, it requires a good knowledge of building’s behaviour and their adaptation to the climatic context. As part of our contribution to this issue, a study on the thermal behaviour of buildings is initiated by numerical simulation. Indeed the building’s energy performance simulation tools are becoming more essential in the building’s design processes and analysis. Investigations are conducted on a building built with typical materials in Burkina Faso by following two main approaches. In the first approach a model of the building is faced with measurements from field experiments on the building. A calibration methodology based on the sensitivity analysis and optimization has been applied for the comparison of results. This helped to calibrate the model and diagnostic studies are performed.In the second approach, investigations on methods which can help to improve the building performance are realized through the application building performance simulation as a design aid tool. Interoperability and optimization techniques are used to deal with passive cooling techniques and their impacts on the building thermal behaviour are assessed. Finally in this work analysis techniques and performance criteria are used to characterize and make recommendations on building designs for the tropical climate context.
257

Análise de estratégias para melhoria do conforto térmico em salas de aulas / Evaluation of strategies to improve thermal comfort on classrooms

Chaves, Victor Leandro Arantes 31 August 2016 (has links)
Submitted by Franciele Moreira (francielemoreyra@gmail.com) on 2018-03-01T13:07:14Z No. of bitstreams: 2 Dissertação - Victor Leandro Arantes Chaves - 2016.pdf: 35798905 bytes, checksum: aa006b5b27f11381be02b866455b36da (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-03-01T13:17:39Z (GMT) No. of bitstreams: 2 Dissertação - Victor Leandro Arantes Chaves - 2016.pdf: 35798905 bytes, checksum: aa006b5b27f11381be02b866455b36da (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-03-01T13:17:39Z (GMT). No. of bitstreams: 2 Dissertação - Victor Leandro Arantes Chaves - 2016.pdf: 35798905 bytes, checksum: aa006b5b27f11381be02b866455b36da (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-08-31 / The unsatisfactory thermal performance of buildings belonging to higher education institutions in Brazil cause users discomfort in classrooms and affect student performance. To ensure the well- being to the user, the use of mechanical systems for cooling of environments such as the use of air conditioners is necessary to reduce air temperature indoor, by one hand, and increase the energy expenditure of the building by about 50%, by the other side. This study analyses thermal comfort and energy efficiency in the School of Civil Engineering and Environmental UFG through measurements "in loco" and the perception of the users as well as by computer simulation. The methodology consists of: a) analysis of architectural design; b) lifting climatic summer data on air temperature and humidity within the classroom, and the views of users in three different situations - with open windows and doors and on evaporative air conditioner, open windows and doors and natural ventilation, and windows and doors closed and air conditioning on -; c) treatment of climatic data; d) comparison of the collected results and the perception of the users; e) evaluation thermal energy by computer simulation and prescriptive method of RTQ-C. They interviewed 200 users. About 83.3% of respondents were dissatisfied in the situation with natural ventilation, 68.5% in the situation on evaporative air conditioner and 70.2% in the situation with air conditioning on. Although the results suggest that the situation using air conditioners is the most comfortable, the number of users who feel uncomfortable is very high in all situations, not meeting the levels recommended by the ISO 7730 (2005). / O comportamento térmico insatisfatório de edifícios pertencentes às instituições de ensino superior no Brasil provoca o desconforto das salas de aula, afetando o desempenho dos alunos, bem como elevam o gasto energético da edificação, devido à utilização de sistemas mecânicos para arrefecimento dos ambientes, sendo que o consumo de energia pode aumentar cerca de 50% devido ao uso de aparelhos condicionadores de ar. Este estudo avalia o conforto térmico e a eficiência energética na Escola de Engenharia Civil e Ambiental da UFG, através de medições “in loco” e a percepção dos usuários, bem como por simulação computacional. A metodologia consiste em: a) análise do projeto arquitetônico; b) levantamento de dados climáticos de verão, temperatura do ar e umidade relativa, dentro da sala de aula, e a opinião dos usuários em três diferentes situações - com janelas e portas abertas e climatizador evaporativo ligado, janelas e portas abertas e ventilação natural, e janelas e portas fechadas e com ar condicionado ligado -; c) tratamento dos dados climáticos; d) comparação dos resultados coletados e a percepção dos usuários; e) avaliação termo- energética por simulação computacional e método prescritivo do RTQ-C. Foram entrevistados 200 usuários. Cerca de 83,3% dos entrevistados estavam insatisfeitos na situação com ventilação natural, 68,5% na situação com climatizador evaporativo ligado e 70,2% na situação com ar condicionado ligado. Apesar dos resultados apontarem que a situação utilizando climatizadores é a mais confortável, o número de usuários que se sente desconfortável é muito alto em todas as situações, não atendendo os níveis recomendados pela ISO 7730 (2005).
258

Soluções projetuais de fachadas para edifícios de escritórios com ventilação natural em São Paulo / Facades design solutions for office buildings with natural ventilation in São Paulo

Mônica Pereira Marcondes 07 June 2010 (has links)
A pesquisa parte da hipótese de que, sob as condições climáticas da cidade de São Paulo, a solução de fachada de um edifício de escritórios, com projeto arquitetônico aprimorado para o desempenho térmico com ventilação natural e uso eficiente (carga térmica interna de 32W/m2), proporciona condições de conforto térmico nos ambientes de trabalho por no mínimo 80% das horas ocupadas do ano sem uso de condicionamento artificial. O objetivo geral é a identificação de soluções projetuais de fachada para edifícios de escritórios com ventilação natural em São Paulo com programa de necessidades, projeto arquitetônico e implantação definidos, tendo em vista o aprimoramento do desempenho térmico do edifício para o conforto térmico dos ocupantes. Levantou-se exemplos de edifícios de escritórios recentes que aclamam ser térmica e energeticamente eficientes para seus contextos, e métodos de avaliação de desempenho térmico e energético de fachadas e de edifícios de escritórios, com destaque para a ventilação natural. Com base em dois modelos de edifício de referência elaborados, sessenta e quatro cenários de edifícios de escritórios com diferentes configurações e condições de ventilação foram avaliados com simulação térmica anual, considerando o clima de São Paulo. Para cada cenário de edifício estabeleceu-se uma relação, adequada às condições desejáveis de conforto térmico dos usuários, entre uma vazão de ar de referência e o ganho máximo de calor no ambiente através da fachada. Os resultados das simulações deram subsídios para o projeto de soluções possíveis de fachadas para os vinte e três casos de edifícios de escritórios que apresentaram no mínimo 80% das horas ocupadas no ano em conforto. Os produtos finais da tese são: (I) dois modelos de edifício de escritórios de referência, com características arquitetônicas e parâmetros de ocupação aprimorados para o desempenho térmico da edificação com ventilação natural sob o clima de São Paulo; (II) método de avaliação de desempenho térmico de edifícios de escritórios com ventilação natural; (III) procedimento para o dimensionamento de soluções de fachada para edifícios de escritórios com ventilação natural; (IV) soluções projetuais de fachada para edifícios de escritórios com ventilação natural e desempenho térmico aprimorado. / The research starts from the hypothesis that, under the climatic conditions of the city of São Paulo, the facades solution of an office building, with an improved architectural design for thermal performance with natural ventilation and an efficient use (internal thermal load of 32W/m2), provides thermal comfort conditions at the work spaces for at least 80% of the occupied hours during the year without use of artificial air conditioning. The main objective is to identify facades design solutions for office buildings with natural ventilation in São Paulo with program of activities, architectural design and site plan defined, considering the improvement of the thermal performance of the building for occupant thermal comfort. Recent examples of office buildings which claim to be thermal and energy efficient to their contexts, and methods of thermal and energy performance evaluation of facades and office buildings, with emphasis on natural ventilation, were listed. Based on two proposed reference models of buildings, sixty four scenarios of office buildings with different configurations and ventilation conditions were evaluated with thermodynamic simulations, considering the climate of São Paulo. For each scenario it was established a relationship, in accordance with users acceptable thermal comfort conditions, between a reference ventilation rate and the maximum heat gain in the office through the façade. The results of the simulations provided inputs for the design of possible facades solutions for twenty three cases of office buildings which presented at least 80% of the annual occupied hours in comfort. The final products of the thesis are: (I) two reference models of office buildings, with architectural design and occupational parameters enhanced for the building thermal performance with natural ventilation under the climatic conditions of São Paulo; (II) thermal performance evaluation method for office buildings with natural ventilation; (III) procedure for the design of facades solutions for office buildings with natural ventilation; (IV) facades design solutions for office buildings with natural ventilation and improved thermal performance.
259

Cidade, vento, energia: limites de aplicação da ventilação natural para o conforto térmico face à densificação urbana em clima tropical úmido / City, wind, energy: limits for applying natural ventilation for thermal comfort in its relation to urban densification in the hot-humid tropical climate

Renan Cid Varela Leite 17 April 2015 (has links)
O objeto desta pesquisa é a alteração das condições de ventilação natural e de incidência solar provocadas pelo meio urbano. Objetiva-se comprovar a hipótese de que o maior adensamento urbano através da verticalização é compatível com o conforto térmico em edifícios residenciais multifamiliares em altura utilizando apenas a ventilação natural durante 80% das horas do ano. Obstáculos no entorno modificam o comportamento do vento, reduzindo ou incrementando o campo de pressões sobre as fachadas. Por outro lado, edifícios altos situados nas proximidades podem reduzir parcelas significativas da radiação solar sobre planos verticais. O estudo tem como foco o clima quente e úmido de Fortaleza (3° S) e analisa quatro diferentes configurações representativas da morfologia urbana presentes nesta cidade. A investigação vale-se de simulações computacionais em diferentes etapas e escalas de abordagem numa metodologia sequencial e complementar na qual cada fase fornece dados necessários ao estágio seguinte. Partiu-se da avaliação da ventilação urbana através de CFD para as duas direções de vento predominantes, que forneceram dados de Cp sobre as aberturas do edifício adotado. Em seguida, simulou-se o comportamento dos fluxos internos, determinando as taxas de renovação do ar e o campo de velocidades no interior do apartamento. O desempenho térmico anual de três ambientes de permanência prolongada foi calculado e os resultados analisados com base no total de horas dentro da zona de conforto utilizando o modelo adaptativo da ASHRAE (2004). A sensação de resfriamento a partir do movimento do ar foi considerada para a extensão dos limites da zona de conforto. A hipótese mostrou-se válida, uma vez que formas urbanas mais verticalizadas como os cenários 2 e 3 obstruíram parcelas significativas da radiação solar em pavimentos mais baixos comparados a conjuntos urbanos formados por edificações mais baixas. Mesmo diante de vazões de ar cerca de 40% mais baixas em alguns casos com vento sudeste, o cenário 2 apresentou maior quantidade de horas em conforto. O mesmo ocorreu com o cenário 3, cujos valores de vazões de ar com vento leste foram discretamente superiores àqueles obtidos nos cenários 1 e 4, porém alcançando maiores períodos em conforto térmico nos pavimentos mais baixos, reforçando a atuação conjunta da obstrução à radiação solar e a manutenção de condições para ventilar naturalmente as fachadas de edifícios. Ao considerar o efeito de resfriamento provocado pelo movimento do ar, foi possível atingir a condição de conforto térmico em 85% dos casos. Ainda, as baixas correlaçõesentre a vazão de ar e a taxa de ocupação do solo em cada cenário ou a altura média das edificações reforçam a premissa de que a variabilidade do vento e o dinamismo da forma urbana impedem a determinação imediata de quais configurações espaciais reduzirão ou potencializarão as condições de ventilação natural, indicando, também, a possibilidade de compatibilizar maiores níveis de densidade urbana e condições ambientais satisfatórias em edifícios. / The object of this research is the changes in natural ventilation conditions and sunlight caused by the urban environment. The aim is to prove the hypothesis that higher urban density levels thru vertical buildings is compatible with thermal comfort in naturally ventilated residential buildings during 80% of total year´s hours. Surrounding obstacles modify wind patterns, reducing or increasing the pressure field over façades. On the other hand, tall buildings located nearby might reduce significant solar radiation portions over vertical planes. This study focus the hot-humid climate of Fortaleza, Ceará, Brazil (3° S) and analyses four different representative urban forms within this city. The investigation uses computational simulations in different stages and approaching scales in a sequential and complementary methodology in which each phase supplies the necessary data to the next level. Starting point was to evaluate the urban ventilation using a CFD tool according to two dominant wind directions, which provided Cp data over buildings openings. Then, internal flows were simulated in order to determine air changes rates and velocity field in the apartment. Annual thermodynamic performance in threelong permanence rooms was calculated and the results were evaluated using ASHRAE (2004) adaptive model. Cooling effect due to air movement was considered to extend the limits of thermal comfort zone. The hypothesis proved to be valid since more vertical urban forms such as scenarios 2 and 3 obstructed significant solar radiation portions over lower floors compared to urban settlements with lower buildings. Even with airflow rates about 40% lower in some cases with southeast wind, scenario 2 had more hours within the comfort zone. The same occurred with scenario 3, in which airflow rates for east wind were slightly higher than that obtained in scenarios 1 and 4, but achieving greater comfort periods in lower floors, reinforcing the combined effect of obstructing solar radiation and maintaining the conditions to naturally ventilate building´s façades. Considering the cooling effect due to air movement made possible to achieve thermal comfort situations in 85% of the cases. Yet, lower correlations between airflow rates and land use in each scenario or average height of buildings reinforce the premise that wind variability and the dynamism of the urban form prevent the immediate determination of which spatial configuration may reduce or enhance natural ventilation conditions, also indicating that high-density urban levels are compatible with satisfactory environmental conditions within buildings.
260

Aproveitamento da ventilação natural nas habitações: um estudo de caso na cidade de Aracaju - SE / Use of housing natural ventilation: a case study in Aracaju city

Luciana Correia do Nascimento Costa 14 August 2009 (has links)
O estudo da ventilação natural como forma de amenização climática tem sido tema de diversos trabalhos científicos apresentados em congressos e encontros da área de conforto ambiental tanto no país como no exterior. E segundo o Método de Givoni, em 74% das horas do ano, a ventilação natural é a principal estratégia de projeto para se obter o conforto térmico dos usuários na cidade de Aracaju SE. Assim sendo, tem-se como objeto desta pesquisa a ventilação natural nas habitações, e como objetivo geral um estudo do aproveitamento do vento para promover a ventilação natural em edificações residenciais na cidade de Aracaju, a fim de proporcionar melhores condições térmicas ambientais para os usuários sem a necessidade do condicionamento artificial do ar. O produto final consiste em recomendações de projeto baseadas nas pesquisas teóricas e simulações computacionais com o ANSYS CFX Computacional Fluid Dynamics Software que serviram de base para verificar a influência da ventilação natural na edificação por meio de propostas de alterações no projeto original. / Studies of natural ventilation as a way to minimize climate influences has been theme of several scientific papers presented in congresses and meetings concerning environmental comfort, in Brazil as well as in other countries. According to Givonis method, in 74% of the year hours, natural ventilation is the main strategy to obtain thermal comfort for the inhabitants of Aracaju (Sergipe capital city). Based on that information, the object of this research is the housing natural ventilation, and its general objective is a study of wind use to promote housing natural ventilation and provide better thermal comfort conditions of its users without the need of artificial air conditioning. The final product of this research consists in design recommendations based on theoretical research and computer simulations with ANSYS CFX Computacional Fluid Dynamics Software which became the base to verify the influence of natural ventilation in a building by proposing alterations in the original project.

Page generated in 0.1269 seconds