• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 84
  • 39
  • 14
  • 1
  • 1
  • 1
  • Tagged with
  • 160
  • 160
  • 97
  • 47
  • 44
  • 39
  • 39
  • 39
  • 38
  • 23
  • 22
  • 21
  • 20
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Geoterminės energijos panaudojimas pastatų grupės energijos poreikiams tenkinti / Analysis of Geothermal Energy Usage for a Group of Buildings

Poškaitė, Viktorija 22 June 2011 (has links)
Darbe projektuojama geoterminė jėgainė, kuri tiekia šiluminę energiją pastatų grupei. Darbą sudaro įvadas, keturi skyriai, išvados ir rekomendacijos bei literatūros sąrašas. Įvade pateikta nagrinėjamos temos problema, aktualumas, darbo tikslai ir uždaviniai bei praktinė darbo vertė. Pirmajame skyriuje pateikiami projektiniai duomenys pastatų grupei Tauragės miesto pavyzdžiu, aprašomi geoterminės energijos tipai bei jos panaudojimas pasaulyje ir Lietuvoje. Antrajame skyriuje analizuojamas Lietuvos geoterminis laukas bei parenkama projektuojamos geoterminės stoties vieta. Analizuojamos UAB „Geoterma“ iškilusios problemos ir nustatomos jų priežastys. Trečiajame skyriuje atliekamas metinio šilumos poreikio modeliavimas bei trijų energijos šaltinių techninis vertinimas kompiuterine programa EnergyPRO. Ketvirtajame skyriuje energijos šaltiniai vertinami ekonominiu ir aplinkosauginiu požiūriu, taip pat atliekama jautrumo analizė bei aprašomos prielaidos, naudotos darbe. Išanalizavus pastatų grupės energijos poreikius, atlikus techninius energijos šaltinių vertinimus ir reikalingus skaičiavimus šilumos gamybos galimybėms įvertinti, teikiamos išvados ir rekomendacijos. Pridedama: trijų energijos šaltinių schemos. Darbo apimtis – 65 p. be priedų, 35 pav., 15 lent., 19 literatūros šaltinių. / There is designed geothermal power plant that supplies thermal energy group of buildings in this paper. The work consists of four chapters, conclusions, recommendations and references. The introduction is about the problem of the topic, the relevance, the work goals, objectives and the practical value of the work. The first chapter provides design details of buildings group using Taurage's city example, describes the types of geothermal energy and its use in the world and in Lithuania. The second chapter analyzes the Lithuanian geothermal area, also the place for designed geothermal station is selected. Analyze the problems encountered in Geoterma company and identify their causes. There is modeling an annual heat demand and performed the three technical evaluation of energy sources with a computer program EnergyPRO. There is assessed the economic sources from energy and environmental point of view in the fourth chapter. As well sensitivity analysis is produced and description of the assumptions used in the workplace. After the analysis of the building group's energy needs and performed technical evaluations and calculations of energy sources necessary to evaluate the heat generation ability, findings and recommendations are provided. Enclosure: energy sources schemes. Working volume - 65 pages without additives, 35 pic., 15 tables, 19 references.
92

Gedimų elektros tinklų 0,4-10 kV linijose tyrimas / Investigation of Faults in 0.4 - 10 kV Power Network

Blėdis, Donatas 02 July 2012 (has links)
Šiame darbe nagrinėjamos skirstomojo tinklo 0,4- 10 kV linijų gedimų problemos, remiantis mokslinės literatūros analize ir praktinio darbo patirties apibendrinimu. Nustatomi Šiaulių regiono kiekvieno rajono elektros tinklų 0,4-10 kV linijų gedimų skaičius, atjungtų vartotojų skaičius, atjungimų trukmės ir priežastys. Apskaičiuojami Šiaulių regiono kiekvieno rajono elektros tinklo patikimumo rodikliai, daugiausiai gendančios elektros linijos parengties ir priverstinės prastovos koeficientai bei veikimo ir gedimo tikimybės per 12 mėnesių. / This paper deals with the distribution network of 0.4 and 10 kV line fault problems based on the scientific literature and practical experience. The number of faults, the number of disconnections, the disconnections times and reasons of 0.4-10 kV grid lines of Šiauliai region have been investigated. Reliability indicators of electrical network of Šiauliai region have been calculated. Working and failure probabilities of the electrical network during 12 months have been calculated.
93

Mažaenerginio administracinio pastato sezoninės energijos poreikių ypatybės / Seasonal Peculiarities of Energy Demands of a Low Energy Office Building

Subačiūtė, Ieva 20 July 2012 (has links)
Baigiamajame magistro darbe nagrinėjamas mažaenergis administracinis pastatas ir AEI panaudojimo jame galimybės Lietuvos meteorologinėmis sąlygomis. Naudojant modeliavimo priemonę TRNSYS sukuriami mažaenerginio administracinio pastato bei AEI sistemų skaičiavimo – valdymo modeliai: saulės kolektoriai, foto elementai, vėjo jėgainės, šilumos siurbliai, imantys šilumą iš grunto bei oro. Atlikus modeliavimą gauti pastato energijos suvartojimai šildymui (54 kWh/m2), vėsinimui (20 kWh/m2) bei elektros (48 kWh/m2). Metiniame pastato energijos balanse, energija pagaminta iš AEI gali padengti 56,6% reikalingos šiluminės energijos, 102,9 % energijos reikalingos vėsinimui ir 4,5 % reikalingo elektros kiekio. Pastato energijos poreikių jautrumo analizė atliekiama 3 pastato variantams. Pastebėta, kad esant didesniam stiklinių atitvarų plotui pietinėje pastato pusėje pagamintas šilumos kiekis iš AEI gali padengti net 85 % pastatui reikalingo šilumos kiekio. Tačiau beveik du kartus išaugo energijos poreikis pastato vėsinimui. Mažiausias vėsinimo kiekis reikalingas stačiakampio ploto pastatui. Apibendrinus rezultatus, pateiktos išvados ir rekomendacijos. Darbą sudaro 5 dalys: įvadas, 5 skyriai, išvados ir rekomendacijos, literatūros sąrašas. Darbo apimtis – 63 p. teksto be priedų, 31 iliustr., 16 lent., 27 bibliografiniai šaltiniai. Atskirai pridedami darbo priedai. / Thesis examined low energy office building and possibilities of renewable energy use in it by Lithuanian meteorology conditions. Using TRNSYS simulation tool the computing-control models for low energy office building and renewable energy systems (RES) (solar collectors, photovoltaic, wind turbines and heat pumps taking the heat from the soil and air) are created. After the simulation buildings’ energy consumption for heating (54kWh/m2), cooling (20 kWh/m2) and electricity (48 kWh/m2) were obtained. The annual building energy balance: an energy produced from RES can cover 56.6 % of the necessary thermal energy, 102.9 % of the energy required for cooling and 4.5 % required for electricity generation. The buildings’ energy demand sensitivity analysis is performed for three buildings’ variants. It is observed that of a larger area of the glass envelope of the building in southern direction the amount of heat produced from RES can cover up to 85% of the building required heat. However, almost twice rises electricity demand in cooling of the building. The minimum amount of cooling is required for a rectangular area building. Summarizing the results, conclusions and recommendations are presented. The work consists of 5 parts: introduction, 5 chapters, conclusions and recommendations, references. Work size – 63 pages without appendices, 31 figures, 16 tables, 27 references. Appendices.
94

Wind Turbine Production losses in Cold Climate : case study of ten wind farms in Sweden

Malmsten, Jon January 2011 (has links)
As wind power expands rapidly worldwide, it is becoming more common to build wind farms in alpine locations where the wind resources often are good and conflicting interests are few. This is evident in Sweden where a substantial portion of the large wind parks planned are to be built in cold climate locations. The fact that icing of turbine blades and sensors can severely impact the production raises the question how large the losses are. In this thesis 10 wind parks comprising 45 turbines, well dispersed throughout Sweden are investigated. Daily production figures are compared to wind data from the MERRA reanalysis data-set in order to see if it is possible to determine the level of losses during the winter period caused by cold climate. A method is suggested where a relationship between daily production and daily average wind speed is established using representative summer days. This relationship is then used to calculate an expected production for the winter period. Losses are concluded as the difference between expected and actual production. The method did not produce a consistent and reliable result for the sites investigated. However, the method captures the overall trend with higher losses in the north of Sweden compared to the sites in the south where little or no icing is likely. At the sites where icing is expected, losses in the range of 10 to 20% of the annual production were calculated.
95

Kvartalo/objekto aprūpinimo šilumine energija variantų analizė / Analysis of Variants of Heat Supply for a District/Object

Pladas, Karolis 11 June 2014 (has links)
Magistro baigiamajame darbe aptariamas Lietuvos ir Europos Sąjungos šalių energetikos sektorius. Apžvelgiamos direktyvos, strategijos, plėtros planai bei teisės aktai skirti energetikos plėtojimui šalyje. Tiriamuoju objektu pasirenkama Trakų Vokės katilinė, kuri aprūpina šiluma kvartalą degindama gamtines dujas vandens šildymo katiluose. Šiame darbe yra nagrinėjamos penkios alternatyvos: kogeneratorius ir dujiniai katilai, kogeneratorius su akumuliacine talpa ir dujiniais katilais, kogeneratorius su akumuliacine talpa ir biokuro katilais, kogeneratorius su akumuliacine talpa ir šilumos siurbliu, medienos dujofikavimo reaktorius su kogeneratoriumi ir vandens šildymo katilais. Alternatyvos yra nagrinėjamos dviem skirtingais scenarijais, kai kogeneratoriaus pagaminta elektra parduodama pagal VIAP tarifus ir pagal „Nord pool spot“ Lietuva biržos kainas. Tiriamasis darbas atliekamas naudojantis „energyPRO“ modeliavimo programa. Atlikus modeliavimą, sistemų veikimas įvertinamas pirminės energijos suvartojimu, ekologiniu ir ekonominiu požiūriais. Atliekama jautrumo analizė keičiant ekonominius rodiklius bei vertinant šilumos gamybą be kogeneracijos. Pagal gautus rezultatus suformuluojamos išvados. Darbą sudaro 10 skyrių. Apimtis – 79 psl. teksto be priedų, 47 iliustracijų, 10 lentelių, 74 bibliografiniai šaltiniai. / In this master thesis, Lithuanian and European Union’s countries energy sector was discussed. An overview was made on EU directives, Lithuanian strategies, development plans and legalizations. Investigation object was Trakų Vokė boiler house with its district heating system. In the boiler house heat produced by combusting natural gas. During the research five alternatives were analysed: cogeneration and heat only boilers, cogeneration with thermal storage and heat only boilers, cogeneration with thermal storage and biomass heat only boilers, cogeneration with thermal storage and high temperature heat pump, biomass gasification reactor with cogeneration and heat only boilers. Alternatives are analysed based on two scenarios, first on when cogeneration is working by fixed electricity tariffs and second when cogeneration is working by liberalized electricity market conditions. Thesis carried out using “energyPRO” modelling software. All modelled systems are assessed by techno-economic and ecological approach. A sensitivity analysis was made by changing economical values and assessing systems without cogeneration. Based on the results conclusion was formed. Thesis includes 10 chapters. Size of work – 79 pages excluding appendixes, 47 pictures, 10 tables, 74 reference sources.
96

Elektrinių ir energijos kaupimo sistemų valdymo modelis vėjo elektrinių galiai balansuoti / Model of power plants and energy storage systems control for wind power balancing

Baranauskas, Audrius 09 January 2015 (has links)
Daktaro disertacijoje tyrinėjamos vėjo elektrinių balansavimo galimybės panaudojant energijos kaupimo sistemas ir sprendžiamas balansavimo galių valdymo uždavinys. Darbo metu buvo ištirta vėjo elektrinių prognozavimo paklaidų įtaka balansavimo galioms, sudaryti balansavimo galių valdymo ir energijos kaupimo sistemų dinaminiai modeliai ir nustatyti tokių sistemų parametrai vėjo elektrinių galių subalansavimui atsižvelgiant į valdymo signalo kitimo greitį ir balansuojančių elektrinių galios keitimo spartą. Darbo išvados ir sukaupta informacija yra reikšminga integruojant energijos kaupimo sistemas į automatinio generavimo valdymo sistemos darbą. Pasiūlyti sprendimai leidžia tiksliau nustatyti reguliavimo rezervo apimtis bei pagerinti sistemos režimo parametrų valdymo kokybę. / Wind power balancing using energy storage systems as well as balancing control strategies are investigated in the thesis. The wind power balancing options are expanded by proposed dynamic models according to control signal rate of change and power plants ramp rates. The influence of wind power forecasting errors to regulating power reserve was investigated. The required energy storage system parameters for wind power balancing were determined and the regulation intensity of conventional power plants was reduced. The results obtained in the thesis are useful for energy storage systems integration into the central automatic generation control system. The solutions proposed let to increase the determination accuracy of regulating active power reserves and improve the quality of the system control parameters.
97

Refurbished and 3D Modeled Thermal Vacuum Chamber

Glenn, Lauren M 01 May 2017 (has links)
Spacecraft testing includes acoustics, vibrations, and thermal vacuum. Cal Poly’s Space Environments Lab is equipped with multiple vacuum chambers, but no thermal vacuum chamber. The purpose of this thesis is to incorporate an ATS Chiller system with the HVEC vacuum chamber so students are able to experiment with a thermal vacuum chamber. The ATS Chiller had leaky pipes that needed to be refurbished and a shroud was implemented to improve thermal capabilities of the system. The full system was able to reach temperatures as low as -38ºC and as high as 58ºC at a pressure of 10-6 Torr. The ATS Chiller was able to absorb up to 500W of heat dissipation from a component mounted to the platen inside of the vacuum chamber. Thermal modeling of the apparatus was performed in Thermal Desktop. The model was incorporated with the test data to extract interface resistance information between connected surfaces. Another model is used to analyze a theoretical component inside the apparatus to evaluate mounting methods and determine theoretical temperatures of the component. The model adjusts for material properties, including thermal conductivity and emissivity to accurately simulate testing conditions within +/- 3ºC. Platen and shroud adjustments were able to accommodate a peak bake out temperature of 130±2.2℃ of any component without damage to the system. Three temperature cycles were performed by the thermal vacuum chamber to reach extreme temperatures of 58℃ and -38. A 300 Watt heater was used to simulate component heat dissipation for the duration of the test. Furthermore, this thesis lays out further possibilities for thermal testing using the HVEC Vacuum chamber and ATS chiller as a thermal vacuum chamber.
98

Návrh a simulace čipu mikrobolometru v MEMS technologii / Design and Simulation of Micro-Bolometer in MEMS Technology

Svatoš, Vojtěch January 2014 (has links)
Tato diplomová práce zkoumá problematiku detektoru infračerveného záření nazývaného bolometr. Cílem je pokrok v detekci infračerveného záření použitím odlišné absorpční vrstvy modifikovanou karbonovými nanotrubicemi. V teoretické části jsou uvedeny základní fyzikální pojmy z problematiky teplotního managmentu a základních fyzikálních vztahů bolometru. Design bolometru je představen a popsán. Teplotně mechanické simulace předvídají chování bolometru při detekci infračerveného záření. PSpice model je vytvořen a kombinuje termální a elektrické vlastnosti čipu bolometru. Dále je uveden proces výroby bolometru, které je detailně popsán.
99

Transformatorinių pastočių skleidžiamų elektromagnetinių laukų tyrimas / Research of electromagnetic fields on transformer substations

Kuprusevičius, Vaidas 18 June 2010 (has links)
Atlikus literatūros apžvalgą, remiantis teoriniais ir eksperimentiniais tyrimais, įsitikinta, kad elektromagnetiniai laukai turi įtakos žmogui ir aplinkai. Elektromagnetinio lauko poveikiui daugiausiai jautri centrinė nervinė ir neuroendokrininė sistemos. Didžiausi elektromagnetinių laukų šaltiniai, gyvenamojoje ir darbo aplinkoje, yra buitiniai prietaisai, elektros perdavimo, transformavimo ir skirstomieji įrenginiai. Elektros įrengimų kuriami elektromagnetiniai laukai, erdvėje sklinda pagal 1/r3; 1/r2 ir 1/r dėsnius. Tai charakteringa tiek elektrinių, tiek magnetinių laukų verčių kitimui. Elektromagnetinių laukų parametrų vertę apsprendžia elektros įrenginių įtampa, srovė ir tiriamo taško padėtis įrenginių atžvilgiu. Įvertinant labai platų mūsų šalies energetikos tinklą, naudojamų elektros įrenginių, kuriančių elektromagnetinius laukus gyvenamoje ir darbo aplinkoje, duomenys apie tai įgauna ženklią socialinę prasmę, sudaroma galimybė prognozuoti galimas silpnų elektromagnetinių laukų poveikio reikšmes, numatyti priemones joms pašalinti. / Literary review, according to theoretical and experimental researches, it was noticed that electromagnetic fields of industrial frequency influence the human and environment. The most sensitive parts to the effect of electromagnetic fields are the nervous system and the neuroendocrine system. The biggest sources of electromagnetic fields are the domestic appliances, the installations of electricity transmission, transference and the distributing installations in residential and working places. Electromagnetic fields are generated with electric installations and spread in space by 1/r3; 1/r2 and 1/r law. It is typical of the value change of electric and magnetic fields. Parameter value of electromagnetic fields is solved with electricity installations tension, stream and the location of analyzed point in point of installations. Summing up the wide energetic net of our country, the fact of usable electric installations (which create electromagnetic fields in residential and working places) assume the marked social signification, there is posed the opportunity to forecast the available values of low electromagnetic fields effect, and to forecast means to remove it.
100

Asinchroninių generatorių tyrimas / Study of the induction generator

Ščerba, Andrius 02 June 2011 (has links)
Darbe atlikti trifazio asinchroninio generatoriaus, sujungto pagal nepriklausomo žadinimo ir pagal susižadinimo schemas, prie įvairių apkrovų eksperimentiniai tyrimai. Pateikti šių tyrimų bei skaičiavimų rezultatai, atlikta jų analizė. Asinchroninio generatoriaus, dirbančio pagal nepriklausomo žadinimo schemą, tyrimų rezultatai rodo, kad jo energetiniai rodikliai nedaug mažesni už nurodytuosius variklio rodiklius. Generatoriaus apvijomis tekant nurodytajai srovei In = 4,7 A, jo atiduodama į tinklą aktyvioji galia P2 = 2,6 kW yra 18,18 % didesnė už nurodytąją variklio galią Pn = 2,2 kW. Asinchroninio generatoriaus, dirbančio pagal susižadinimo schemą esant pastoviam jo sukimo greičiui (n = const) ir kondensatorių talpai (C = = const), tyrimai rodo, kad šio generatoriaus energetiniai rodikliai yra ženkliai mažesni už nurodytuosius variklio rodiklius. Didėjant generatoriaus apkrovai gana sparčiai mažėja jo fazinė įtampa. Generatoriaus didžiausia apkrovos srovė I1 = 2,68 A, kuri buvo išmatuota esant sukimo greičiui n = 2000 min-1 = const ir kondensatorių talpai C = 120 μF = const, yra 43 % mažesnė už nurodytąją variklio srovę. Todėl galima teigti, kad asinchroninis generatorius, dirbantis pagal susižadinimo schemą, nebus pilnai išnaudotas. Atlikti tyrimai rodo, kad asinchroninį generatorių, dirbantį pagal susižadinimo schemą, galima daugiau apkrauti didinant jo įtampą. Kad tai pasiekti, reikia, didinant generatoriaus apkrovą, atitinkamai didinti jo sukimo greitį arba (ir)... [toliau žr. visą tekstą] / The present work presents an experimental research of a three-phase induction generator which was connected using separate excitation and self-excitation schemes under various loads. The results of the research and the calculations are provided and analyzed. The research results obtained from the separately excited induction generator show that its energetic indicators are not significantly lower than the provided motor indicators. When the rated current In = 4,7 A flows through the windings of the generator, its released active power P2 = 2,6 kW is greater than the rated motor power Pn = 2,2 kW by 18,18 %. The research on a self-excited induction generator with a constant revolution speed (n = const) and capacity of its capacitors (C = const) shows that the energetic indicators of this generator are of significantly lower values than the provided motor indicators. When the load of the generator is increased, its phase voltage decreases rather rapidly. The maximum load current I1 = 2,68 A of the generator was measured under the following conditions: the rotational speed n = 2000 min-1 = const and the capacity of the capacitors C = 120 μF = const. The results showed that it was 43 % less than the rated motor current. Therefore, it can be concluded that a self-excited induction generator will not be exploited to its full capacity. The carried out research shows that it is possible to increase the load of a self-excited induction generator by increasing its voltage. It is... [to full text]

Page generated in 0.137 seconds