• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 591
  • 22
  • 17
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 642
  • 315
  • 237
  • 171
  • 127
  • 126
  • 113
  • 84
  • 82
  • 82
  • 80
  • 73
  • 69
  • 58
  • 53
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Valores normativos para o eletrorretinograma de campo total

JACOB, Mellina Monteiro 02 May 2012 (has links)
Submitted by Irvana Coutinho (irvana@ufpa.br) on 2012-06-08T16:17:12Z No. of bitstreams: 2 Dissertacao_MELLINAValoresNormativosEletro.pdf: 4797106 bytes, checksum: b86a051a620a524491d2f888ddfea0be (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Approved for entry into archive by Irvana Coutinho(irvana@ufpa.br) on 2012-06-08T16:17:53Z (GMT) No. of bitstreams: 2 Dissertacao_MELLINAValoresNormativosEletro.pdf: 4797106 bytes, checksum: b86a051a620a524491d2f888ddfea0be (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2012-06-08T16:17:53Z (GMT). No. of bitstreams: 2 Dissertacao_MELLINAValoresNormativosEletro.pdf: 4797106 bytes, checksum: b86a051a620a524491d2f888ddfea0be (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2012 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / FINEP - Financiadora de Estudos e Projetos / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Muitos laboratórios de eletrofisiologia visual não possuem seus próprios valores de normalidade para o eletrorretinograma de campo total. Isto prejudica a confiabilidade dos diagnósticos de diversas doenças que afetam as vias visuais. Desta forma, o objetivo deste trabalho foi estabelecer os valores normativos para o teste Eletrorretinograma de Campo Total para o Laboratório de Neurologia Tropical (LNT) da Universidade Federal do Pará (UFPA). Realizaram o eletrorretinograma 68 indivíduos saudáveis e sem queixas visuais divididos em três grupos de acordo com a faixa etária: 36 indivíduos pertenceram ao grupo 1 (entre 17 e 30 anos), 21 indivíduos ao grupo 2 (entre 31 e 45 anos) e 11 indivíduos ao grupo 3 (entre 46 e 60 anos). O protocolo de realização do teste seguiu as recomendações da ISCEV, com a utilização de seis tipos de estimulação. Quatro após adaptação escotópica e estimulação com intensidades de: 0,01 cd.s/m2 (resposta de bastonetes), 3,0 cd.s/m2 (resposta mista de cones e bastonetes e potenciais oscilatórios) e 10,0 cd.s/m2 (resposta mista adicional). Dois após adaptação fotópica em fundo de 30 cd/m2: 3,0 cd.s/m2 (resposta de cones e Flicker 30Hz). Para a análise dos resultados foram calculados os valores de amplitude e tempo implícito das ondas a e b obtidas em resposta a cada um dos seis tipos de estimulação utilizados. Estes valores foram descritos estatisticamente através da mediana, intervalos de confiança, 1º e 3º quartis, coeficiente de variação, média, desvio padrão e valores mínimos e máximos. Os grupos de maior faixa etária apresentaram menores valores de amplitude e atraso no tempo implícito. A utilização da transformada wavelet permitiu a melhor visualização das ondas sem alteração de amplitude e tempo implícito. Portanto, os valores normativos obtidos podem servir como parâmetros de normalidade confiáveis para auxiliar o diagnóstico de doenças retinianas. / Many visual electrophysiology laboratories don’t have their own normal values for full-field electroretinogram. This impairs the reliability of the diagnosis of various diseases affecting the visual pathways. Thus, the purpose of this study was to establish normative values for the full-field electroretinogram to the Laboratory of Tropical Neurology (LNT) of the Federal University of Pará (UFPA). Were tested using the electroretinogram 68 healthy subjects without visual complaints, divided into three groups according to age group: 36 subjects belonged to group 1 (17 to 30 years), 21 subjects in group 2 (31 to 45 years) and 11 individuals in group 3 (46 to 60 years). Six types of stimulus that follow ISCEV standards were presented. Four dark-adapted: 0.01 cd.s/m2 (rod response), 3.0 cd.s/m2 (mixed response and oscillatory potentials) and 10.0 cd.s/m2 (mixed additional response). Two light-adapted, 3.0 cd.s/m2 (Cone response and Flicker 30Hz), with 30 cd/m2 background adaptation. For analysis, a-wave and b-wave amplitude and implicit times values were calculated. These values were statistically described using the following values: median, confidence interval, 1st and 3rd quartiles, coefficient of variation, mean, standard deviation and minimum and maximum values. The older age groups had lower amplitude and delayed implicit time. Wavelet transform allowed better visualization of waves without change of amplitude and implicit time. Therefore, the normative values obtained can serve as reliable parameters of normality to assist the diagnosis of retinal diseases.
192

Verificação de assinaturas manuscritas baseadas em seus sons acústicos e wavelet-packets / Handwritten signature verification based on acoustic sounds and wavelet-packet

Armiato, Daniel Angelotti, 1989- 11 September 2018 (has links)
Orientador: Yuzo Iano / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-09-11T21:25:51Z (GMT). No. of bitstreams: 1 Armiato_DanielAngelotti_M.pdf: 5330178 bytes, checksum: 79e61a5abcacd171b5d1b92be5e9afff (MD5) Previous issue date: 2015 / Resumo: A verificação de assinaturas utilizando algoritmos de imagem, já é uma realidade à algum tempo. Visando preencher as lacunas deixadas por esse tipo de sistema, um novo fator biométrico é alvo de estudos. Pensando em inserir dados referentes ao momento em que se dá a assinatura, uma nova abordagem vem sendo utilizada. Ao invés de analisar uma imagem, toma-se como base o som que é produzido no ato da assinatura, gerado pelo atrito entre a caneta e a superfície de suporte. O processo de falsificação é dificultado, uma vez que o falsário precisará de informações da grafia da assinatura original e também dos aspectos referentes à dinâmica (velocidade, força e ordem de escrita dos caracteres que compõem a assinatura) que o assinante legítimo desempenha ao assinar. Nesse trabalho, adotou-se tal abordagem biométrica. Foi desenvolvido um dispositivo e um software, que juntos, são capazes de realizar a captura do som emitido durante a assinatura dos usuários. De posse disso, foi gerada uma base de assinantes legítimos e outra com as referentes falsificações, e então, colocou-se o sistema à prova. Afim de tornar as comparações possíveis, gerou-se vetores de características, extraídas com base na transformada Wavelet-Packet discreta. As comparações foram feitas por dois métodos distintos, ambos Pattern-Matching, sendo que o primeiro está embasado no cálculo de distâncias Euclidianas, e o segundo, em uma fórmula de pontuação baseada em correlação, originalmente desenvolvida / Abstract: The signature verification by imaging algorithms is already a reality. Aiming to fill the gaps left by this type of system, a new biometric factor is the subject of this study. In order to include data to be analysed at the time the signs occur, a new approach has been used. Instead of analyzing an image, the sound that is produced in the act of sign is used, and it is generated by the friction between the pen and the supporting surface. The falsification process is difficult, since the forger needs the graphic form of the original signature and also the aspects relating to its dynamic (speed, strength and written order of the characters of the signature) In this paper, we adopted this biometric approach. We developed a device and a software, which, combined, are able to capture the sound made during the moment of the signing. We generated a legitimate and a fake subscriber base, and then they were placed in the system to the test. In order to make comparisons, feature vectors were generated based on the discrete Wavelet-Packet transform. Comparisons were made by two different methods, both Pattern-Matching, the first of which is grounded in Euclidean calculation, and the second one based on a correlation formula of score, originally developed / Mestrado / Telecomunicações e Telemática / Mestre em Engenharia Elétrica
193

Algoritmos distribuídos empregados na extração de descritores morfológicos e não morfológicos em mamogramas

Jacomini, Ricardo de Souza January 2012 (has links)
Orientador: Marcelo Zanchetta do Nascimento / Dissertação (mestrado) - Universidade Federal do ABC. Programa de Programa de Pós-Graduação em Engenharia da Informação, 2012
194

Algoritmos computacionais baseados em coeficientes curvelet aplicados na descrição de textura em mamogramas

Bruno, Daniel Otávio Tambasco January 2013 (has links)
Orientador: Marcelo Zanchetta do Nascimento / Dissertação (mestrado) - Universidade Federal do ABC. Programa de Programa de Pós-Graduação em Engenharia da Informação, 2013
195

Resistência à fratura, grau de conversão, adaptação marginal e contração de polimerização de uma resina composta bulk-fill / Fracture strength, degree of conversion, marginal adaptation and polymerization shrinkage of a bulk-fill resin composite

Jassé, Fernanda Ferreira [UNESP] 23 July 2014 (has links) (PDF)
Made available in DSpace on 2017-03-14T14:10:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-07-23. Added 1 bitstream(s) on 2017-03-14T14:42:46Z : No. of bitstreams: 1 000874607.pdf: 1410162 bytes, checksum: 67077172f37d022a566709e94dd314a2 (MD5) / O objetivo neste trabalho foi avaliar diferentes propriedades de uma resina composta bulk-fill fluida de baixo tensão de contração, por meio de três estudos: 1) avaliação da resistência à fratura de molares com cavidades classe II MOD restaurados com a resina bulk-fill; 2) avaliação do grau de conversão monomérica (GC%) por meio de espectroscopia FTIR (Espectroscopia Infravermelho Transformada de Fourier); e 3) avaliação da adaptação marginal cervical em esmalte e dentina, e da contração de polimerização. Para o estudo de resistência à fratura, 40 molares foram divididos em cinco grupos: 1- dentes hígidos (controle positivo); 2- dentes com cavidades classe II MOD sem restauração (controle negativo); 3- dentes com cavidades classe II MOD restaurados apenas com a resina bulk-fill; 4- dentes com cavidades classe II MOD restaurados com a resina bulk-fill recoberta por resina composta convencional nano-híbrida; e 5- dentes com cavidades classe II MOD restaurados apenas com a resina convencional nano-híbrida. Todos os espécimes foram submetidos ao teste de resistência à fratura por meio de carga compressiva axial, com o emprego de esfera metálica medindo 8 mm de diâmetro, em máquina de ensaio universal EMIC DL-2000, equipada com célula de carga de 10 kN, acionada a uma velocidade de 5 mm/min até que ocorresse a fratura do conjunto. Os dados de resistência à fratura foram submetidos à Análise de Variância (ANOVA) e teste de Tukey (! = 0,05). Para análise do grau de conversão foram confeccionados espécimes cilíndricos (4mm x 4mm) da resina, divididos nas profundidades de polimerização de 1mm, 2mm, 3mm e 4mm. Os espécimes foram foto-ativados pelos tempos de 20 e 40 segundos, e foram então triturados, prensados com KBr e analisados em espectrofotômetro FTIR. Os dados relativos ao GC% foram analisados estatisticamente... (Resumo completo, clicar acesso eletrônico abaixo) / The aim of this study was to evaluate different properties of a low-shrinkage stress bulk-fill flow composite resin, through three studies: 1) evaluation of the fracture strength of molars with Class II MOD cavities restored with the bulk-fill resin; 2) evaluation of degree of conversion (DC%) by means of FTIR (Fourier Transform Infrared) spectroscopy; and 3) evaluation of cervical marginal adaptation in enamel and dentin, and polymerization shrinkage. For the study of fracture strength, 40 molars were divided into five groups: 1- intact teeth (positive control); 2- teeth with Class II MOD cavities without restoration (negative control); 3- teeth with Class II MOD cavities restored with only bulk-fill resin; 4- teeth with Class II MOD cavities restored with bulk-fill resin covered with conventional nano-hybrid resin; and 5- teeth with Class II MOD cavities restored with only the conventional nano-hybrid resin. All specimens were subjected to fracture strength test by means of axial compressive load, using a metal sphere measuring 8 mm in diameter, in an universal testing machine EMIC DL-2000 equipped with 10 kN load cell, which was triggered at a speed of 5 mm/min until the fracture of the specimen. Data of fracture resistance were subjected to Analysis of Variance (ANOVA) and Tukey's test (! = 0.05). To analyze DC% cylindrical specimens (4mm x 4mm) of the resin were made and divided into the depths of polymerization of 1mm, 2mm, 3mm and 4mm. The specimens were photo-activated by the times of 20 and 40 seconds, and then they were crushed, pressed with KBr (potassium bromide) and analyzed by FTIR spectrophotometer. Data for DC% were statistically analyzed by two-way ANOVA. For the third study, which evaluated the cervical marginal adaptation and polymerization shrinkage, at first, 24 molars were divided into three groups (A, B and C) ... (Complete abstract electronic access below)
196

Investigação dos efeitos das impurezas alcalinas e hidrogênio no quartzo submetido à eletrodifusão e radiação ionizante /

Rosa, Rafael Augusto dos Anjos. January 2014 (has links)
Orientador: Keizo Yukimitu / Banca: Victor Ciro Solano Reynoso / Banca: Sandro Márcio Lima / Resumo: No presente trabalho, investigaram-se os efeitos dos íons alcalinos Na+, Li+ substituídos pelo íon H+ e Na+ nos centros relacionados ao alumínio que é uma impureza encontrada naturalmente nas matrizes de quartzo natural. Foram realizadas medidas de absorção óptica na região do visível e do ultravioleta, assim como medidas no infravermelho de amostras de quartzo natural que passaram ou não pelo processo de eletrodifusão. Foi investigado um efeito de escurecimento no quartzo citrino quando este é exposto ao sol, correlacionando com os centros estudados no presente trabalho, [AlO4/H], [Li-OH] e [Na-OH], identificáveis na região do infravermelho e os centros [AlO4]0 e E' identificáveis no espectro de absorção óptica. A existência desses centros, chamados de centros de impurezas, é facilitada pela presença de um canal estrutural no quartzo, o qual permite a entrada de íons substitucionais como Al3+ e intersticiais Na+, Li+ e H+ junto a cadeia cristalina do quartzo. As amostras foram submetidas à radiação gama de dose aproximada a 20kGy, o resultado foi analisado com base nos centros estudados e os efeitos da eletrodifusão foram analisados por espectroscopia na região do UV-Vis e Infravermelho. A análise infravermelha indicou que a eletrodifusão de hidrogênio no quartzo citrino e hialino foi bem sucedida, uma vez que observa-se um incremento no centro [AlO4/H]0 e um decréscimo no centro [Li-OH], localizado na banda em 3484cm-1. A interação entre a radiação gama e o quartzo faz com que os centros relacionados à presença de hidrogênio com o alumínio aumentem, pois, a radiação ao excitar os átomos da rede do quartzo acaba por afetar diretamente os centros cujo compensador de carga são os átomos alcalinos Li+,Na+ e K+ do centro [AlO4/M]0, havendo então a compensação por átomos de hidrogênio, formando então mais centros [AlO4/H]0. O aparecimento das bandas em 430 ... / Abstract: In the present study, we investigated the effects of alkali ions Na+ , Li+ replaced by ion H+ and Na+ in the center related to the aluminum that is a found naturally in motrices natural quartz. Measurements of optical absorption in the visible and ultraviolet region and measures infrared samples of natural quartz that have passed or not by electrodiffusion process were performed. An effect of browning in citrine quartz was investigated when exposed to the sun , correlating with the centers studied in this work, [ AlO4/H]0 , [ Li-OH ] and [Na-OH] , identifiable in the infrared region in the centers [AlO4]0 and E' that are identifiable in the optical absorption spectrum. The existence of such centers, centers called impurities is facilitated by the presence of a structural channel quartz, which allows the entry of ions such as substitutional Al3+ substitutional and interstitial as Na+, Li+ and H+ along the crystal quartz chain . The samples were submitted to gamma radiation dose of approximately 20kGy , the outcome was analyzed based on the centers and the effects of electrodiffusion were analyzed by spectroscopy, UV- Vis and IR region. Infrared analysis indicated that the hydrogen electrodiffusion in citrine and hyaline quartz was successful , since there is an increase in the center [AlO4/H]0 and a decrease in the [Li-OH] , located in the band at 3484cm -1. The interaction between gamma radiation and quartz causes the centers related to the presence of hydrogen with aluminum increase , because the radiation to excite the atoms of the quartz network ultimately directly affect the centers whose compesator load are the alkali atoms Li+ , Na+ and K+ center [AlO4/M]0 , then there is compensation for hydrogen atoms , thus forming more centers [AlO4/H]0 . The appearance of bands at 430 and 620 nm associated to the center [AlO4]0 in the citrine and hyaline quatz after irradiation, enables us to state that ... / Mestre
197

Intercalamento temporal por transformada de Fourier: um novo método robusto para transmissão de sinais de TV Digital. / Fourier transform based time interleaving.

Guido Stolfi 04 June 2008 (has links)
Este trabalho apresenta um novo algoritmo, denominado Intercalamento Temporal por Transformada de Fourier (FTI), desenvolvido para complementar sistemas de modulação digital. Com este processo, a informação é distribuida de forma difusa ao longo de um conjunto de símbolos, tanto no domínio do tempo como no da frequência. Constitui-se em um processo computacionalmente eficiente, especialmente adequado para operar em conjunto com a modulação OFDM, e que apresenta consideráveis ganhos de desempenho em algumas situações de degradação; por exemplo, é mais tolerante a ruídos impulsivos de longa duração do que a modulação OFDM convencional. Apresenta-se também um outro mecanismo, denominado de Realimentação de Erro, que melhora o desempenho do sistema em praticamente todas as situaçoes analisadas. Embora implique em aumento da carga computacional, este processo consiste de uma operação determinística, que dispensa etapas de iteração ou recursos computacionais distintos dos já disponíveis. Neste trabalho foi avaliada a utilização destas técnicas em um sistema OFDM com características similares ao sistema ISDB-T, adequado para radiodifusão de TV Digital . / This work introduces a new transform-based time interleaving algorithm: FTI-OFDM (Fourier Transform Interleaved OFDM), in which binary information is spread over several symbols, both in time and frequency domains. This process, designed to be included in digital modulation systems, is computationally efficient when used in conjunction with OFDM modulation. Simulations are used to show its superiority over the usual binary time interleaving used in ordinary OFDM under several impairment scenarios, that include long impulsive noise and deep fading. Also introduced in this work is the additional method of decision error feedback (ERF), that enhances the performance of FTI-OFDM in almost all situations. Furthermore, ERF is deterministic and non-iterative and employs the same computational resources found in OFDM systems. The performance of an FTI-OFDM system, similar to ISDB-T standard, is evaluated under several impairments, such as are found in Digital TV broadcasting environment.
198

Sistema de monitoramento e metodologia de estimativa dos tempos de operação do disjuntor. / Monitoring system and methodology to estimation of circuit breaker operation times.

Milthon Serna Silva 04 April 2005 (has links)
O presente trabalho visa o desenvolvimento de um sistema de monitoramento de disjuntor voltado a coletar informações para manutenção preditiva. São analisadas as características das variáveis que são monitoradas através de sensores ligados ao disjuntor, sua aquisição e o tratamento das informações. Um protótipo foi desenvolvido e instalado na subestação de Sumaré 440kV de ETEO (Empresa de Transmissão de Energia do Oeste Paulista). Um assunto importante para a manutenção é a avaliação dos tempos envolvidos na movimentação dos contatos principais do disjuntor principalmente na operação de abertura do curto circuito. Para tal é proposto um sistema não intrusivo que analise a oscilografia das tensões e correntes no disjuntor sincronizado com as correntes no circuito de disparo deste equipamento. A Transformada de Fourier aplicada no sinal de corrente/tensão sem perturbação permite determinar o valor do componente fundamental desse sinal. Com esse valor pode-se gerar uma senóide que superposta com o sinal coletado pelo oscilógrafo permite visualizar a alteração. A Transformada Wavelet é realizada através de filtros decompondo-se o sinal de corrente ou tensão em Análise Multiresolução, em diferentes estágios obtendo-se em cada, uma versão chamada aproximação (baixas freqüências) e uma de detalhes (altas freqüências), sendo assim, os distúrbios podem ser detectados e localizados no tempo em função do seu conteúdo de freqüência. / The present work addresses the development of a circuit breaker monitoring system so as to collect information for predictive maintenance. The characteristics of the variables that are monitored through certain sensors linked to the circuit breaker, its acquisition and the treatment of the information, are analyzed. A prototype was developed and installed at the 440kV Sumaré substation of ETEO (Empresa de Transmissão de Energia do Oeste Paulista) a Brazilian Transmission Company. An important aspect for the maintenance is the evaluation of the times involved in the movement of the circuit breaker main contacts, mainly at the opening operation for example during a short circuit. On this respect, a non-intrusive system that analyzes the oscillography of both voltages and currents in the circuit breaker synchronized with the currents in the tripping circuit of this equipment is proposed. The Fourier Transform applied to the current or voltage signal with no disturbance allows to determine the value of the fundamental component of this signal. With that value, it can be generated a pure sine wave which when overlapped to the signal collected by the oscillograph allows to visualize alterations. The Wavelet Transform is realized through filters and decomposing the current or voltage signal through the Multiresolution Analysis at different levels, in this way, obtaining in each level, a version called approximation (low frequencies) and another with details (high frequencies), thus, the disturbances can be detected and located in the time and as a function of its frequency content.
199

Modelagem do mCSEM no domínio do tempo usando transformada discreta de Fourier

MIRANDA, Diego da Costa January 2009 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-11-14T13:29:37Z No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_ModelagemMcsemDominio.pdf: 2587982 bytes, checksum: 128281a90d0470ea7eb6ca5d50968966 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-11-14T17:15:28Z (GMT) No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_ModelagemMcsemDominio.pdf: 2587982 bytes, checksum: 128281a90d0470ea7eb6ca5d50968966 (MD5) / Made available in DSpace on 2014-11-14T17:15:28Z (GMT). No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_ModelagemMcsemDominio.pdf: 2587982 bytes, checksum: 128281a90d0470ea7eb6ca5d50968966 (MD5) Previous issue date: 2009 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / A modelagem do mCSEM é feita normalmente no domínio da frequência, desde sua formulação teórica até a análise dos resultados, devido às simplificações nas equações de Maxwell, possibilitadas quando trabalhamos em um regime de baixa frequência. No entanto, a abordagem através do domínio do tempo pode em princípio fornecer informação equivalente sobre a geofísica da subsuperfície aos dados no domínio da frequência. Neste trabalho, modelamos o mCSEM no domínio da frequência em modelos unidimensionais, e usamos a transformada discreta de Fourier para obter os dados no domínio do tempo. Simulamos ambientes geológicos marinhos com e sem uma camada resistiva, que representa um reservatório de hidrocarbonetos. Verificamos que os dados no domínio do tempo apresentam diferenças quando calculados para os modelos com e sem hidrocarbonetos em praticamente todas as configurações de modelo. Calculamos os resultados considerando variações na profundidade do mar, na posição dos receptores e na resistividade da camada de hidrocarbonetos. Observamos a influência da airwave, presente mesmo em profundidades oceânicas com mais de 1000m, e apesar de não ser possível uma simples separação dessa influência nos dados, o domínio do tempo nos permitiu fazer uma análise de seus efeitos sobre o levantamento. Como parte da preparação para a modelagem em ambientes 2D e 3D, fazemos também um estudo sobre o ganho de desempenho pelo uso do paralelismo computacional em nossa tarefa. / The mCSEM modelling is usually done in the frequency domain, from its theoretical formulation to the analysis of the results. However, the time domain approach is, in principle, capable of providing equivalent information about the geo-electric structure of the subsurface. In this work, we model frequency domain mCSEM data in 1-D environments, then we perform the discrete Fourier transform to obtain time domain results. We simulated marine geological environments with and without the resistive layer that represents the hydrocarbon reservoir. We verified that the time domain data are significantly different when calculated for models with and without hydrocarbons in almost all model configurations. We calculated the results considering variations in the sea depth, in the position of the receivers and in the resistivity of the hydrocarbon layer. We observed the influence of the airwave, even at sea depths greater than 1000m, and although a simple separation of this influence on data is not possible, the time domain allowed us to do an analysis of its effects on the survey. As part of the preparation for the 2-D and 3-D modelling, we also have studied the gain in performance from the use of parallel processing in our task.
200

Solução de equações de balanço populacional usando a técnica da transformada de Laplace e filtro de partículas / Solution of a general population balance equation by the laplace transform and particles filter techniques

BATISTA, Clauderino da Silva 12 1900 (has links)
Submitted by Nathalya Silva (nathyjf033@gmail.com) on 2017-04-24T19:49:26Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_SolucaoEquacoesBalanco.pdf: 13765561 bytes, checksum: 76cb5628e30109a10b363ed3f225400e (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-04-25T21:39:33Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_SolucaoEquacoesBalanco.pdf: 13765561 bytes, checksum: 76cb5628e30109a10b363ed3f225400e (MD5) / Made available in DSpace on 2017-04-25T21:39:33Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_SolucaoEquacoesBalanco.pdf: 13765561 bytes, checksum: 76cb5628e30109a10b363ed3f225400e (MD5) Previous issue date: 2011-12 / A evolução da distribuição do tamanho de partículas em muitos campos da ciência aplicada como cristalização, física de aerossol, química coloidal e processo de polimerização, pode ser obtida pela solução da equação de balanço populacional (PBE). A técnica da transformada de Laplace com inversão numérica foi usada para resolver uma equação integro-diferencial parcial que relaciona a modelagem matemática do problema físico para estudar processos convectivos com taxas de nascimento e morte de partículas e aerossóis. Tal modelo é governado PBE, na qual leva em consideração a nucleação, crescimento e processos de coagulação. Um método Bayesiano foi usado para resolver o problema inverso hiperbólico e não-linear, e estimar a função densidade de tamanho de partículas, e assim prever o comportamento dinâmico do sistema físico. Especificamente o filtro de partículas com amostragem e Reamostragem por Importância Sequencial (SIR) foi utilizado como metodologia de solução do problema. Através dessas soluções, resultados numéricos foram obtidos e comparados com os disponíveis na literatura para sistemas particulados, permitindo uma avaliação crítica da presente metodologia de solução. / The evolution of particle size distribution in many fields of applied science, such as crystallization, aerosols, colloids, and polymer processing, can be obtained by solving population balance equation (PBE). The Laplace transform technique with numerical inversion was used to solve an integro-partial-differential equation related to the mathematical modeling of the physical problem to study convective processes with birth and death rates of particles or aerosols. Such model is governed by the population balance equation (PBE), in which is taken into account the nucleation, growth and coagulation processes. A Bayesian method was employed to solve the hyperbolic and non-linear inverse problem and estimate the size distribution density function, thus predicting the dynamic behavior of the physical system. Specifically the particle filter with sampling Importance Resampling (SIR) has been applied as a method of solving the problem. From these solutions, numerical results were obtained and compared with those in the literature for particulate systems permitting a critical evaluation of the present solution methodology.

Page generated in 0.0428 seconds