• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 128
  • 112
  • 29
  • 15
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • Tagged with
  • 353
  • 353
  • 117
  • 95
  • 75
  • 47
  • 47
  • 44
  • 42
  • 41
  • 41
  • 38
  • 35
  • 34
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

Optimum Corona Ring Design for High Voltage Compact Transmission Lines Using Gaussian Process Model

January 2012 (has links)
abstract: Electric utilities are exploring new technologies to cope up with the in-crease in electricity demand and power transfer capabilities of transmission lines. Compact transmission lines and high phase order systems are few of the techniques which enhance the power transfer capability of transmission lines without requiring any additional right-of-way. This research work investigates the impact of compacting high voltage transmission lines and high phase order systems on the surface electric field of composite insulators, a key factor deciding service performance of insulators. The electric field analysis was done using COULOMB 9.0, a 3D software package which uses a numerical analysis technique based on Boundary Element Method (BEM). 3D models of various types of standard transmission towers used for 230 kV, 345 kV and 500 kV level were modeled with different insulators con-figurations and number of circuits. Standard tower configuration models were compacted by reducing the clearance from live parts in steps of 10%. It was found that the standard tower configuration can be compacted to 30% without violating the minimum safety clearance mandated by NESC standards. The study shows that surface electric field on insulators for few of the compact structures exceeded the maximum allowable limit even if corona rings were installed. As a part of this study, a Gaussian process model based optimization pro-gram was developed to find the optimum corona ring dimensions to limit the electric field within stipulated values. The optimization program provides the dimen-sions of corona ring, its placement from the high voltage end for a given dry arc length of insulator and system voltage. JMP, a statistical computer package and AMPL, a computer language widely used form optimization was used for optimi-zation program. The results obtained from optimization program validated the industrial standards. / Dissertation/Thesis / M.S. Electrical Engineering 2012
212

Estudo e desenvolvimento de antena de microfita aplicada à veículos aéreos não tripulados para inspeção em linhas de transmissão

Pereira, Thomas Tadeu de Oliveira 07 February 2018 (has links)
Submitted by Vanessa Christiane (referencia@ufersa.edu.br) on 2018-04-25T19:00:54Z No. of bitstreams: 1 ThomasTOP_DISSERT.pdf: 5209914 bytes, checksum: dc0480e3c31cf33dad2055a2722ab763 (MD5) / Approved for entry into archive by Vanessa Christiane (referencia@ufersa.edu.br) on 2018-06-18T16:53:46Z (GMT) No. of bitstreams: 1 ThomasTOP_DISSERT.pdf: 5209914 bytes, checksum: dc0480e3c31cf33dad2055a2722ab763 (MD5) / Approved for entry into archive by Vanessa Christiane (referencia@ufersa.edu.br) on 2018-06-18T17:02:42Z (GMT) No. of bitstreams: 1 ThomasTOP_DISSERT.pdf: 5209914 bytes, checksum: dc0480e3c31cf33dad2055a2722ab763 (MD5) / Made available in DSpace on 2018-06-18T17:02:51Z (GMT). No. of bitstreams: 1 ThomasTOP_DISSERT.pdf: 5209914 bytes, checksum: dc0480e3c31cf33dad2055a2722ab763 (MD5) Previous issue date: 2018-02-07 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In wireless communications, there is a growing need for more compact and portable systems. In this context, research related to the development of antennas has intensified in recent years, especially those related to microstrip antennas, since these have unique properties as well as several applications. In this work, two different antenna configurations were designed, an array of microstrip antennas for the transmitting device and a single element with an omnidirectional pattern for the receiver, according to the needs of the application. The antennas are designed by the Transmission Line Theory according to the frequency of radio operation and the electrical and physical properties of the substrates used. The results were obtained through simulations in the ANSYS HFSS® software, and the best results were used to fabricate the devices in order to validate the simulations performed. The results of the simulations reached the characteristics of the application, as the return losses of both antennas were in accordance with the frequency band of the application in the band ISM in 2.4 GHz, with respect to the behavior of the radiation, the antenna proposed to the transmitter had a gain of 6.1 dB, approximately three times greater than the commonly used dipole / monopole antenna. The experimental result of the loss of return was shown to be in agreement with the simulated standard, in spite of the frequency displacement, both antennas constructed were suitable for application in the radio control of the UAV, having the microstrip array 7.5 MHz of bandwidth in the band of application and the simple element proposed to the 58.5 MHz receiver. The antennas were then implemented in the radiofrequency system and a range test was performed in order to verify the communication of the devices, presenting satisfactory results. Thus, a flight is performed via software for visual inspection of transmission lines, aiming the collection of images for analysis / Em comunicações sem fio, existe uma crescente necessidade por sistemas mais compactos e portáteis. Nesse contexto, as pesquisas relacionadas ao desenvolvimento de antenas têm se intensificado nos últimos anos, em especial, as relacionadas às antenas de microfita, visto que estas possuem propriedades singulares, bem como diversas aplicações. Neste trabalho foram projetadas duas configurações distintas de antenas, um arranjo de antenas de microfita para o dispositivo transmissor e um elemento simples com padrão omnidirecional para o receptor, de acordo com as necessidades da aplicação. As antenas são projetadas pela Teoria da Linha de Transmissão de acordo com a frequência de operação do rádio e as propriedades elétricas e físicas dos substratos utilizados. Os resultados foram obtidos através de simulações no software ANSYS HFSS®, e os melhores resultados foram utilizados para fabricação dos dispositivos a fim de validar as simulações realizadas. Os resultados das simulações atingiram as características da aplicação, pois as perdas de retorno de ambas antenas apresentaram conformidade com a faixa de frequências da aplicação na banda ISM em 2,4 GHz, no que diz respeito ao comportamento da radiação, a antena proposta ao transmissor teve ganho de 6,1 dB, aproximadamente três vezes maior do que a antena dipolo/monopolo comumente utilizada. O resultado experimental do coeficiente de reflexão se mostrou concordante com o padrão simulado, apesar do deslocamento de frequência, ambas antenas construídas se adequaram para aplicação no rádio controle do VANT, tendo o arranjo de microfita 7,5 MHz de largura de banda na faixa de aplicação e o elemento simples proposto ao receptor 58,5 MHz. Em seguida, as antenas foram implementadas no sistema de radiofrequência e foi realizado um teste de alcance a fim de averiguar a comunicação dos dispositivos, apresentando resultados satisfatórios. Desse modo, um voo foi realizado para inspeção visual de linhas de transmissão, visando a coleta de imagens para análise / 2018-04-25
213

Estudo em túnel de vento do arrasto aerodinâmico sobre torres treliçadas de linhas de transmissão / Wind tunnel study of the aerodynamic drag forces on transmission lines lattice towers

Rippel, Leandro Inácio January 2005 (has links)
Estruturas treliçadas de linhas de transmissão submetidas à ação do vento têm sido utilizadas de forma rotineira em aplicações da engenharia estrutural há mais de um século. Entretanto, o conhecimento dos efeitos do vento sobre este tipo de estrutura é, ainda hoje, imperfeito e as prescrições das normas a respeito destes efeitos são, em muitos casos, mutuamente inconsistentes e em desacordo com os dados experimentais. Partindo deste contexto, no caso particular de estruturas para linhas de transmissão, podemos acrescentar que as normas existentes não são, em princípio, aplicáveis à maior parte das geometrias utilizadas nos projetos das torres. Além disso, maiores níveis de segurança e confiabilidade são atingidos quando a consideração criteriosa dos efeitos do vento é feita a partir da etapa de concepção sendo, geralmente, este o processo de menor custo e de maior eficiência. Sabe-se também que o modelo físico adotado para consideração dos carregamentos difere do real, seja pela forma de atuação ou pela complexidade para estimativa da interação entre fluido-estrutura. Nesse sentido, através do presente trabalho procurou-se: desenvolver e aperfeiçoar instrumentos e técnicas de medição de coeficientes de arrasto; verificar a aplicabilidade dos critérios de estimativa do carregamento devido ao vento sobre trechos de estruturas treliçadas; propor coeficientes de arrasto compatíveis com geometrias tradicionalmente utilizadas em torres de linhas de transmissão determinados a partir da aplicação de dois critérios de área de referência, a saber, área calculada e área projetada; além de comparar os resultados experimentais com outras referências como normas técnicas de projeto. Este trabalho de pesquisa contempla o estudo de duas torres de suspensão autoportantes em túnel de vento. Para a realização dos ensaios, através de modelos reduzidos, cada torre foi dividida em módulos. Os módulos foram ensaiados para diferentes ângulos de incidência do vento e também para diferentes níveis de velocidade do vento. As forças de arrasto sobre os modelos foram determinadas através de uma balança de forças unidirecional instalada na base da câmara de ensaios. / Transmission lines lattice structures submitted to wind action have been widely used in structural engineering applications for more than a century. However, the knowledge of the wind effect on this type of structure is yet imperfect, being the codes recommendations, in several cases, inconsistent and in disagreement with the experimental data. From this point of view, in the particular case of transmission lines structures, we can add that the existing codes are not, in principle, applicable to a large amount of geometries used in the towers design. Furthermore, largest safety and reliability levels are reached when careful consideration of the wind effects is made from the conception stage, being this process, in general, the less costly and the most efficient. It is also known that the physical model adopted for the consideration of the loads differs from the real, either for the way in which the load is really applied or the complexity for an accurate estimate of the fluid-structure interaction. In this sense, the present work had the aim of: developing and improving instrumentation and measurement techniques for drag coefficients; verifying the applicability of the criteria for estimating wind loads on modules of lattice structures; proposing drag coefficients applicable to geometries traditionally adopted in transmission lines towers, obtained from the application of the two reference areas criteria, calculated area and projected area; as well as comparing experimental results with other references such as design codes. The research contemplates wind tunnel studies of two self-supported suspension towers. For the accomplishment of the tests, through scaled models, each tower was divided in modules. The modules had been tested for different angles of incidence of the wind and also for different wind speeds. The drag forces on the models were measured through a unidirectional force balance installed in the base of the models.
214

Modelagem numérica do comportamento de fundações profundas submetidas a carregamento lateral

Lautenschläger, Carlos Emmanuel Ribeiro January 2010 (has links)
O presente trabalho apresenta o desenvolvimento de um modelo de previsão de capacidade de carga de estacas, utilizadas em torres e postes de linhas de transmissão de energia elétrica, segundo esforços horizontais, considerando-se as parcelas coesiva e friccional dos solos, bem como um estudo relacionado à melhoria das propriedades do solo nas regiões mais solicitadas. Tal estudo está vinculado a um projeto de Pesquisa e Desenvolvimento da Companhia Estadual de Energia Elétrica – CEEE, em parceria com a Universidade Federal do Rio Grande do Sul, que visa estabelecer metodologias de capacidade de carga de fundações de linhas de transmissão sob condições distintas de carregamento. A análise do comportamento de estacas sob carregamento lateral foi baseada em simulações numéricas tridimensionais, através do método dos elementos finitos, utilizando-se o software ABAQUS. As simulações ocorreram após extensiva revisão bibliográfica acerca dos métodos de dimensionamento de estacas sob carregamento lateral, modelos constitutivos e propriedades geotécnicas de solos característicos do Rio Grande do Sul, em condições natural, compactada e cimentada. Nas simulações, foram levados em conta parâmetros geotécnicos que representassem os diferentes tipos de solos levantados, bem como a geometria da estaca e o mecanismo de ruptura apresentado mediante solicitação, identificados de acordo com os métodos apresentados. O modelo constitutivo adotado para a condução do programa de simulações foi o de Mohr-Coulomb, o qual foi testado e verificado a partir da simulação numérica de ensaios triaxiais e provas de carga de arrancamento em sapata e carregamento lateral em estaca. A partir dos resultados das simulações, foi realizada a análise da influência de cada parâmetro de entrada sobre a resposta do conjunto solo-estaca, em termos de carga horizontal atingida, deflexão da estaca e deformações do solo, para cada geometria. Os parâmetros que apresentaram maior influência foram coesão, módulo de Young e ângulo de atrito interno. A partir desta análise, para cada geometria estabeleceu-se uma lei de comportamento para estacas submetidas ao carregamento lateral, que relaciona a carga horizontal com um fator de parâmetros que agrega as variáveis mais influentes, contemplando as características coesivo-friccionais do solo. Quanto à geometria, observou-se que, em estacas mais curtas, ocorre a tendência ao giro do elemento estrutural, o qual apresenta menores regiões de concentração de tensões em relação às estacas mais longas, que tendem à formação de rótulas plásticas. A profundidade onde se encontram os maiores níveis de tensão na estaca não variou entre estacas longas de igual diâmetro, assim como a magnitude das tensões no conjunto, indicando que a partir de certa profundidade crítica (relacionada ao diâmetro da estaca e às propriedades geotécnicas do substrato) o aumento da profundidade da estaca é irrelevante. A análise de isovalores de tensão e deslocamentos do solo auxiliou na identificação da área de maior solicitação mediante carregamento horizontal, indicando as regiões onde deveria haver melhorias. O tratamento avaliado foi radial à estaca, tendo-se variado o seu diâmetro e sua profundidade, abrangendo a região mais solicitada. Os resultados demonstraram melhorias significativas mesmo com volumes de tratamento relativamente pequenos. A taxa de melhoria de resistência aumentou com o nível de deflexão relativa, sendo aparentemente função do volume de tratamento. / This paper shows the development of a prediction model of pile's loading capacity, used in towers and poles of electrical energy transmission, with horizontal loading, considering the cohesive and frictional portions of the ground, as well as a study regarding the improvement of the soil’s properties in the most requested areas. Such work is connected to a Research and Development Project of State Company of Electric Energy – CEEE, in partnership with the Federal University of Rio Grande do Sul – UFRGS, with the objective of establishing methodologies of bearing capacity of transmission lines' foundations under different conditions of loading. The analysis of the behavior of piles under lateral loading was based on tridimensional numerical simulations, through the finite element method, being used the ABAQUS software for such calculations. The simulations took place after extensive search through literature regarding design methods of piles under lateral loading, constitutive models and geotechnical properties of soils considered typical in the RS, in natural conditions, compacted and cemented. During the simulations, geotechnical parameters that represent the different kinds of studied soils were taken into account, as well as the geometry of the pile and the rupture mechanism shown by request, identified according to the presented methods. The constitutive model adopted for the conclusion of the simulation program was the one by Mohr-Coulomb, which was tested and verified through the numerical simulation of triaxial tests, uplift load tests on shallow foundation and lateral loading tests on pile. As of the results taken from the simulations, the analysis of the influence of each key parameter on the soilstructure’s behavior took place, in terms of reached horizontal load, deflection of the pile and soil deformation, for each geometry. The parameters that presented more influence were the cohesion, Young’s module and friction angle. From this analysis, for each geometry it was established a behavior law for piles under lateral loading, that relates the horizontal loading with a parameters factor that adds the most influent variables, contemplating the cohesivefrictional characteristics of the soil. When regarding the geometry, it was observed that, in shorter piles there is a tendency to the foundation’s rotation, which presents smaller areas of stress concentration when compared to longer piles, which tend to the formation of yielding hinges. The depth in which the highest stress levels in the pile can be found didn’t vary amidst long piles of same diameter, as well as the magnitude of stresses on foundation system, indicating that from an established critic depth (related to the foundation’s diameter and to the geotechnical properties of the substrate) the increase in the pile’s depth is irrelevant. The analysis of contours of stress and displacements of the soil helped in the identification of the area of greatest request by horizontal loading, indicating the zones where improvements should be done. The treatment evaluated was around the pile, having its diameter and its depth varied, covering the most requested area. The results showed significant improvements even with relatively small improvement fill. The rate of improvement of resistance increased with the level of relative deflection, apparently being function of the treatment volume.
215

Stitched transmission lines for wearable RF devices

Daniel, Isaac H. January 2017 (has links)
With the rapid growth and use of wearable devices over the last decade, the advantages of using portable wearable devices are now been utilised for day to day activities. These wearable devices are designed to be flexible, low profile, light-weight and smoothly integrated into daily life. Wearable transmission lines are required to transport RF signals between various pieces of wearable communication equipment and to connect fabric based antennas to transmitters and receivers; the stitched transmission line is one of the hardware solutions developed to enhance the connectivity between these wearable devices. Textile manufacturing techniques that employ the use of sewing machines alongside conductive textile materials can be used to fabricate the stitched transmission line. In this thesis the feasibility of using a sewing machine in fabrication of a novel stitched transmission line for wearable devices using the idea of a braided coaxial cable have been examined. The sewing machine used is capable of a zig-zag stitch with approximate width and length within the range of 0-6 mm and 0-4mm respectively. The inner conductor and the tubular insulated layer of the stitched transmission lines were selected as RG 174, while the stitched shields were made up of copper wires and conductive threads from Light Stiches®. For shielding purpose, the structure is stitched onto a denim material with a conductive thread with the aid of a novel manufacturing technique using a standard hardware. The Scattering Parameters of the stitched transmission line were investigated with three different stitch angles 85°, 65° and 31° through simulation and experiments, with the results demonstrating that the stitched transmission line can work usefully and consistently from 0.04 to 4GHz. The extracted Scattering parameters indicated a decrease in DC loss with increased stitch angle and an increase in radiation loses, which tends to increase with increase in frequency. The proposed stitched transmission line makes a viable transmission line but a short stitch length is associated with larger losses through resistance. The DC losses observed are mainly influenced by the resistance of the conductive threads at lower frequencies while the radiation losses are influenced by the wider apertures related to the stitch angles and increase in frequency along the line. The performances of the stitched transmission line with different stitch patterns, when subjected to washing cycles and when bent through curved angles 90° and 180° were also investigated and results presented. Also, the sensitivity of the design to manufacturing tolerances was also considered. First the behaviour of the stitched transmission line with two different substrates Denim and Felt were investigated with the results indicating an insignificant increase in losses with the Denim material. Secondly, the sensitivity of the design with variations in cross section dimensions was investigated using numerical modelling techniques and the results showed that the impedance of the stitched transmission line increases when the cross sectional dimensions are decreased by 0.40mm and decreases when the cross sectional dimensions are increased by 0.40mm. Equally, repeatability of the stitched transmission line with three different stitch angles 85°, 65° and 31° were carried out. The results were seen to be consistent up to 2.5GHz, with slight deviations above that, which are mainly as a result of multiple reflections along the line resulting in loss ripples. The DC resistance of the stitched transmission line with three different stitch angles 85°, 65° and 31° corresponding to the number of stitches 60,90 and 162 were computed and a mathematical relationship was derived for computing the DC resistance of the stitch transmission line for any given number of stitches. The DC resistance computed results of 25.6Ω, 17.3Ω and 13.1Ω, for 31°, 65° and 85° stitch angles, indicated an increase in DC resistance of the stitch with decrease in stitch angle which gives rise to an increase in number of stitches. The transfer impedance of the stitched transmission line was also computed at low frequency (< 1GHz) to be ZT=(0.24+j1.09)Ω, with the result showing the effectiveness of the shield of the stitched transmission line at low frequency (< 1GHz).
216

Intégration monolithique de composants bipolaires et de circuits radiofréquences sur substrats mixtes silicium/silicium poreux / Monolithic integration of bipolar devices and radiofrequency circuits on porous silicon/silicon hybrid substrates

Capelle, Marie 17 December 2013 (has links)
Le récent essor des systèmes de communication sans fil implique le développement de circuits RF performants, à fort taux d’intégration, bas coût, et adaptés à la production de masse. L’intégration monolithique de systèmes RF sur silicium permet de répondre en partie à ces critères. Cependant, le silicium est responsable de pertes dans le substrat dégradant les performances des composants passifs. Pour adresser cette limite, des caissons isolants de silicium poreux peuvent être réalisés au sein du silicium (substrat mixte). Les objectifs de cette thèse sont de montrer la faisabilité de l’intégration monolithique sur substrat mixte et d’étudier son impact sur les performances de circuits RF. Ce manuscrit décrit l’élaboration des substrats mixtes et donne une comparaison des performances de composants passifs intégrés sur silicium poreux et sur substrats standards. Enfin, l’intégration monolithique de circuits RF est menée sur substrat mixte 6’’. La caractérisation de ces démonstrateurs montre une amélioration des performances par rapport au silicium. De plus, la compatibilité du substrat mixte avec un procédé industriel de microélectronique est validée. / The rapid growth of wireless systems involves the development of highly efficient, large-scale, low-cost and radio frequency (RF) systems. Monolithic integration of RF circuits on silicon can enhance the appeal of this technology further. However, in order to fully realize the next generation of system-on-chip on silicon, the losses which results in to degradation in the performances of passive components need to be addressed. This work investigates locally insulating porous silicon regions on silicon substrates, targeting highly efficient passive components. This thesis begins with a detailed description of porous silicon/silicon hybrid substrate fabrication using a novel mask. The influence of the hybrid substrate on fabricated passive device performances was studied and the results were compared to similar devices on conventional silicon substrates. Finally, monolithic integration of passive and active devices was demonstrated on 6” hybrid substrates, with performance improvements when compared with standard silicon. This work has also shown that hybrid substrates can be fully integrated into industrial scale microelectronic processes.
217

Avaliação teórica, numérica e probabilística de fundações tracionadas. / Theoretical, numerical and probabilistic evaluation of shallow foundations under tensile loading.

Danielle da Silva Arpino 21 December 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A geotecnia constitui uma disciplina relativamente recente na área da engenharia civil, e dessa disciplina faz parte um capítulo ainda menos estudado que trata de fundações submetidas a esforços de tração. O presente trabalho deriva do conjunto de provas de cargas realizado para um importante projeto de linhas de transmissão que permitiu a aferição da teoria de capacidade de carga à tração da Universidade de Grenobel, cujos estudos comparativos mostram bons resultados para fins de aplicações práticas. De posse da extensa documentação técnica produzida e documentada por esse estudo foi possível comparar os resultados obtidos pelas provas de cargas e os resultados teóricos com os resultados das modelagens 2D axisimetricas por elementos finitos. Além dessas análises, foi possível verificar a variação da resistência à tração através de análises paramétricas realizadas a partir da variação da coesão e do ângulo de atrito. Os estudos apresentados reafirmam a confiabilidade das teorias da Universidade de Grenoble, que contemplam a simplicidade desejada às aplicações de cunho prático, com resultados satisfatórios em relação àqueles obtidos nos ensaios de tração. Por outro lado, as análises paramétricas realizadas indicaram a tendência de comportamento que a resistência à tração deve apresentar para diferentes parâmetros do solo. O conhecimento dessas tendências permite ao projetista avaliar os fatores de segurança sob ponto de vista probabilístico, ou seja, permite o emprego de fatores de segurança com o conhecimento da probabilidade de ruína associada. As análises probabilísticas foram traçadas a partir do emprego de funções genéricas de várias variáveis no formato FOSM (First Order Second Moment) que fornecem soluções aproximadas para o cálculo de desvio padrão quando não existe uma amostragem representativa. Ao término das análises, obteve-se como resultado, o mapa comparativo da probabilidade de ruína para os mesmos fatores de segurança empregados com base em resistências estimadas através de diferentes métodos de cálculos (Universidade de Grenoble e modelagem computacional). / Geotechnical engineering is a relatively recent area of civil engineering, which comprises the much less studied topic of foundations under tensile loads. Based on an extensive literature review this paper presents a set of foundation uplift tests carried out for an important transmission line project that allowed to compare the test results with the theory developed at the University of Grenoble, with fairly good results for practical purposes. The test results have also been compared to axisymmetric finite element analysis, also with satisfactory results. This study also presents parametric variations of the soil strength parameters to estimate the variation of the tensile foundation capacity based on sequentially increasing values of cohesion and friction angle. The parametric variation of the soil strength parameters was intended to provide the necessary insight to a complementary probabilistic analysis presented at the end of this dissertation. This work confirms the adequacy and simplicity of the theoretical framework developed at the University of Grenoble comparably to more refined techniques such as finite element analysis, providing a valuable tool for practical design applications. The probabilistic analysis was based on standard FOSM (First Order Second Moment ) approximation, providing estimates of the standard deviation of the tensile foundation capacities to better understand expected variations of the foundation uplift capacity in practical problems.
218

Modelagem numérica do comportamento de fundações profundas submetidas a carregamento lateral

Lautenschläger, Carlos Emmanuel Ribeiro January 2010 (has links)
O presente trabalho apresenta o desenvolvimento de um modelo de previsão de capacidade de carga de estacas, utilizadas em torres e postes de linhas de transmissão de energia elétrica, segundo esforços horizontais, considerando-se as parcelas coesiva e friccional dos solos, bem como um estudo relacionado à melhoria das propriedades do solo nas regiões mais solicitadas. Tal estudo está vinculado a um projeto de Pesquisa e Desenvolvimento da Companhia Estadual de Energia Elétrica – CEEE, em parceria com a Universidade Federal do Rio Grande do Sul, que visa estabelecer metodologias de capacidade de carga de fundações de linhas de transmissão sob condições distintas de carregamento. A análise do comportamento de estacas sob carregamento lateral foi baseada em simulações numéricas tridimensionais, através do método dos elementos finitos, utilizando-se o software ABAQUS. As simulações ocorreram após extensiva revisão bibliográfica acerca dos métodos de dimensionamento de estacas sob carregamento lateral, modelos constitutivos e propriedades geotécnicas de solos característicos do Rio Grande do Sul, em condições natural, compactada e cimentada. Nas simulações, foram levados em conta parâmetros geotécnicos que representassem os diferentes tipos de solos levantados, bem como a geometria da estaca e o mecanismo de ruptura apresentado mediante solicitação, identificados de acordo com os métodos apresentados. O modelo constitutivo adotado para a condução do programa de simulações foi o de Mohr-Coulomb, o qual foi testado e verificado a partir da simulação numérica de ensaios triaxiais e provas de carga de arrancamento em sapata e carregamento lateral em estaca. A partir dos resultados das simulações, foi realizada a análise da influência de cada parâmetro de entrada sobre a resposta do conjunto solo-estaca, em termos de carga horizontal atingida, deflexão da estaca e deformações do solo, para cada geometria. Os parâmetros que apresentaram maior influência foram coesão, módulo de Young e ângulo de atrito interno. A partir desta análise, para cada geometria estabeleceu-se uma lei de comportamento para estacas submetidas ao carregamento lateral, que relaciona a carga horizontal com um fator de parâmetros que agrega as variáveis mais influentes, contemplando as características coesivo-friccionais do solo. Quanto à geometria, observou-se que, em estacas mais curtas, ocorre a tendência ao giro do elemento estrutural, o qual apresenta menores regiões de concentração de tensões em relação às estacas mais longas, que tendem à formação de rótulas plásticas. A profundidade onde se encontram os maiores níveis de tensão na estaca não variou entre estacas longas de igual diâmetro, assim como a magnitude das tensões no conjunto, indicando que a partir de certa profundidade crítica (relacionada ao diâmetro da estaca e às propriedades geotécnicas do substrato) o aumento da profundidade da estaca é irrelevante. A análise de isovalores de tensão e deslocamentos do solo auxiliou na identificação da área de maior solicitação mediante carregamento horizontal, indicando as regiões onde deveria haver melhorias. O tratamento avaliado foi radial à estaca, tendo-se variado o seu diâmetro e sua profundidade, abrangendo a região mais solicitada. Os resultados demonstraram melhorias significativas mesmo com volumes de tratamento relativamente pequenos. A taxa de melhoria de resistência aumentou com o nível de deflexão relativa, sendo aparentemente função do volume de tratamento. / This paper shows the development of a prediction model of pile's loading capacity, used in towers and poles of electrical energy transmission, with horizontal loading, considering the cohesive and frictional portions of the ground, as well as a study regarding the improvement of the soil’s properties in the most requested areas. Such work is connected to a Research and Development Project of State Company of Electric Energy – CEEE, in partnership with the Federal University of Rio Grande do Sul – UFRGS, with the objective of establishing methodologies of bearing capacity of transmission lines' foundations under different conditions of loading. The analysis of the behavior of piles under lateral loading was based on tridimensional numerical simulations, through the finite element method, being used the ABAQUS software for such calculations. The simulations took place after extensive search through literature regarding design methods of piles under lateral loading, constitutive models and geotechnical properties of soils considered typical in the RS, in natural conditions, compacted and cemented. During the simulations, geotechnical parameters that represent the different kinds of studied soils were taken into account, as well as the geometry of the pile and the rupture mechanism shown by request, identified according to the presented methods. The constitutive model adopted for the conclusion of the simulation program was the one by Mohr-Coulomb, which was tested and verified through the numerical simulation of triaxial tests, uplift load tests on shallow foundation and lateral loading tests on pile. As of the results taken from the simulations, the analysis of the influence of each key parameter on the soilstructure’s behavior took place, in terms of reached horizontal load, deflection of the pile and soil deformation, for each geometry. The parameters that presented more influence were the cohesion, Young’s module and friction angle. From this analysis, for each geometry it was established a behavior law for piles under lateral loading, that relates the horizontal loading with a parameters factor that adds the most influent variables, contemplating the cohesivefrictional characteristics of the soil. When regarding the geometry, it was observed that, in shorter piles there is a tendency to the foundation’s rotation, which presents smaller areas of stress concentration when compared to longer piles, which tend to the formation of yielding hinges. The depth in which the highest stress levels in the pile can be found didn’t vary amidst long piles of same diameter, as well as the magnitude of stresses on foundation system, indicating that from an established critic depth (related to the foundation’s diameter and to the geotechnical properties of the substrate) the increase in the pile’s depth is irrelevant. The analysis of contours of stress and displacements of the soil helped in the identification of the area of greatest request by horizontal loading, indicating the zones where improvements should be done. The treatment evaluated was around the pile, having its diameter and its depth varied, covering the most requested area. The results showed significant improvements even with relatively small improvement fill. The rate of improvement of resistance increased with the level of relative deflection, apparently being function of the treatment volume.
219

Estudo em túnel de vento do arrasto aerodinâmico sobre torres treliçadas de linhas de transmissão / Wind tunnel study of the aerodynamic drag forces on transmission lines lattice towers

Rippel, Leandro Inácio January 2005 (has links)
Estruturas treliçadas de linhas de transmissão submetidas à ação do vento têm sido utilizadas de forma rotineira em aplicações da engenharia estrutural há mais de um século. Entretanto, o conhecimento dos efeitos do vento sobre este tipo de estrutura é, ainda hoje, imperfeito e as prescrições das normas a respeito destes efeitos são, em muitos casos, mutuamente inconsistentes e em desacordo com os dados experimentais. Partindo deste contexto, no caso particular de estruturas para linhas de transmissão, podemos acrescentar que as normas existentes não são, em princípio, aplicáveis à maior parte das geometrias utilizadas nos projetos das torres. Além disso, maiores níveis de segurança e confiabilidade são atingidos quando a consideração criteriosa dos efeitos do vento é feita a partir da etapa de concepção sendo, geralmente, este o processo de menor custo e de maior eficiência. Sabe-se também que o modelo físico adotado para consideração dos carregamentos difere do real, seja pela forma de atuação ou pela complexidade para estimativa da interação entre fluido-estrutura. Nesse sentido, através do presente trabalho procurou-se: desenvolver e aperfeiçoar instrumentos e técnicas de medição de coeficientes de arrasto; verificar a aplicabilidade dos critérios de estimativa do carregamento devido ao vento sobre trechos de estruturas treliçadas; propor coeficientes de arrasto compatíveis com geometrias tradicionalmente utilizadas em torres de linhas de transmissão determinados a partir da aplicação de dois critérios de área de referência, a saber, área calculada e área projetada; além de comparar os resultados experimentais com outras referências como normas técnicas de projeto. Este trabalho de pesquisa contempla o estudo de duas torres de suspensão autoportantes em túnel de vento. Para a realização dos ensaios, através de modelos reduzidos, cada torre foi dividida em módulos. Os módulos foram ensaiados para diferentes ângulos de incidência do vento e também para diferentes níveis de velocidade do vento. As forças de arrasto sobre os modelos foram determinadas através de uma balança de forças unidirecional instalada na base da câmara de ensaios. / Transmission lines lattice structures submitted to wind action have been widely used in structural engineering applications for more than a century. However, the knowledge of the wind effect on this type of structure is yet imperfect, being the codes recommendations, in several cases, inconsistent and in disagreement with the experimental data. From this point of view, in the particular case of transmission lines structures, we can add that the existing codes are not, in principle, applicable to a large amount of geometries used in the towers design. Furthermore, largest safety and reliability levels are reached when careful consideration of the wind effects is made from the conception stage, being this process, in general, the less costly and the most efficient. It is also known that the physical model adopted for the consideration of the loads differs from the real, either for the way in which the load is really applied or the complexity for an accurate estimate of the fluid-structure interaction. In this sense, the present work had the aim of: developing and improving instrumentation and measurement techniques for drag coefficients; verifying the applicability of the criteria for estimating wind loads on modules of lattice structures; proposing drag coefficients applicable to geometries traditionally adopted in transmission lines towers, obtained from the application of the two reference areas criteria, calculated area and projected area; as well as comparing experimental results with other references such as design codes. The research contemplates wind tunnel studies of two self-supported suspension towers. For the accomplishment of the tests, through scaled models, each tower was divided in modules. The modules had been tested for different angles of incidence of the wind and also for different wind speeds. The drag forces on the models were measured through a unidirectional force balance installed in the base of the models.
220

Um modelo para condutores múltiplos considerando a distribuição da corrente nos subcondutores

Costa, Eduardo Coelho Marques da [UNESP] 27 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-27Bitstream added on 2014-06-13T18:08:29Z : No. of bitstreams: 1 costa_ecm_me_ilha.pdf: 1777300 bytes, checksum: f5e35375b4a1e9e034ae9b487436cef5 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente trabalho descreve detalhadamente uma metodologia alternativa para o cálculo dos parâmetros longitudinais e transversais de um condutor múltiplo genérico, com base na configuração de um condutor equivalente. A metodologia proposta considera precisamente o acoplamento mútuo entre os subcondutores que compões o feixe, a natureza distribuída dos parâmetros e a distribuição da corrente, uniforme ou desigual, através dos subcondutores. São calculados e analisados os parâmetros utilizando a metodologia alternativa proposta e o procedimento clássico baseado na obtenção de um condutor equivalente aplicando o conceito do Raio Médio Geométrico (RMG), para diversos condutores múltiplos, sendo eles simétricos ou não simétricos, convencionais ou não-convencionais. Posteriormente, são comparados os resultados obtidos por ambos os métodos e a partir desses é possível comprovar a eficácia da metodologia proposta e eventuais situações em que a metodologia clássica, envolvendo o conceito do RMG, apresenta algumas imprecisões derivadas da distribuição não uniforme da corrente em condutores múltiplos assimétricos ou pouco convencionais / The present work describes an alternative methodology to evaluate the longitudinal and transversal parameters of a generic bundled conductor, based on the configuration of an equivalent conductor. The proposed methodology considers precisely the mutual coupling among subconductors of the bundle, the distributed nature of parameters and the current distribution through subconductors. The parameters are calculated and analyzed using the proposed alternative methodology and the classic procedure, based on equivalent conductor applying the concept of Geometric Mean Radius (GMR), for several bundled conductors, symmetric or nonsymmetric, conventional or non-conventional. Subsequently, the obtained results are compared to both methods and then it is possible to verify the efficacy of the proposed methodology and eventual situations where the classic methodology, based on RMG concept, presents inaccuracies due to the non-uniform distribution of the current in non-symmetric or non-conventional bundled conductors

Page generated in 0.1431 seconds