Avaliações técnico-operacionais em estações de tratamento de água dos municípios das regiões leste e dos lagos do Estado do Rio de Janeiro, com propostas de melhorias para futura implantação de sistema de gestão ambiental baseado nas normas ISO 14.000. / Technical-operational evaluations in water treatment stations of the cities of the regions east and the lakes of Rio de Janeiro State with proposals of improvements for future implantation of environmental management system based in norms ISO 14.000.José Rogério da Conceição Ramos 19 March 2008 (has links)
Na gestão de recursos hídricos, as questões relacionadas aos impactos ambientais
causados pelas Estações de Tratamento de Água não podem ser negligenciadas, devendo ser
avaliadas em todos seus aspectos. Neste trabalho foram avaliadas as condições técnicasoperacionais
e a gestão de seis Estações de Tratamento de Água de pequeno porte situadas nas
regiões leste e dos lagos do estado do Rio de Janeiro. Os resultados apresentam dados de
produção de água tratada, perdas de água contabilizadas com lavagem de filtros e descargas
de decantadores e as não contabilizadas, gastos de energia e produtos químicos, produção de
resíduos e seu destino final, bem como levantamento da capacitação do pessoal de operação,
comparados com valores de literatura para ETAs consideradas eficientes. A partir da
discussão dos resultados concluiu-se que há necessidade de correções de operação e
manutenção das ETAs e monitoramento da qualidade das águas bruta e tratada,
recomendando-se que a empresa de saneamento, efetivamente, implante melhorias para uma
posterior implantação, em cada unidade, de um sistema de gestão ambiental, baseado nas
normas ISO 14.000. / In Water Resources Management the questions related with environmental impact
caused by Water Treatment Plants (WTPs) cannot be neglected, and they must be evaluated in
every aspect. In this work it was evaluated the technical and operational conditions and the
management of six small Water Treatment Plants located on the regions East and the Lakes of
the State of Rio de Janeiro. The result presents data on treated water production, entered water
losses caused by filter cleaning and decantors discharges, and not-entered losses, energy and
chemical products expenses, residual production and its final destination, also the survey of
operational staff capacitation compared to the literature values to the considered efficient
WTPs. From the discussion of the results we conclude that corrections on the operation and
maintenance of the WTPs are necessary, and a management of the raw and treated water
quality, also we recommend to the sanitation service company to improve effectively in a
future implantation a system of ambient management in each unit, based on ISO 14.000.
|
322 |
Cobertura florestal e custo do tratamento de águas em bacias hidrográficas de abastecimento público: caso do manancial do município de Piracicaba. / Forest cover and the cost of water treatment in municipal watershades: the case of the Piracicaba municipal watershed.Lúcia Vidor de Sousa Reis 26 October 2004 (has links)
A sociedade necessita de indicadores capazes de medir a susceptibilidade ao risco de degradação de um manancial de abastecimento público. O percentual de cobertura florestal de uma bacia hidrográfica pode ser utilizado como um dos indicativos na avaliação da qualidade de um manancial de abastecimento público. O custo do tratamento de águas provenientes de bacias hidrográficas com diferentes percentuais de cobertura florestal é um componente que pode subsidiar discussões sobre a importância da cobertura florestal em mananciais de abastecimento público, como recurso ambiental a ser priorizado pelo poder público e exigido pela sociedade, tendo em vista os benefícios econômicos e de minimização de riscos à saúde humana. O trabalho determinou os custos do tratamento da água proveniente de bacias hidrográficas com diversos percentuais de cobertura florestal através da análise das características operacionais de diversas Estações de Tratamento de Água (ETAs) e suas respectivas captações. Para seis dos sete sistemas e ETAs estudadas, o custo específico com produtos químicos na ETA eleva- se com a redução do percentual de cobertura florestal da bacia de abastecimento. Não se pretendeu situar e associar a localização das áreas de cobertura florestal a outros fatores como, por exemplo, a susceptibilidade do solo à erosão ou ao percentual de área florestada situada em APPs. Considerando-se o enfoque do trabalho sobre a qualidade de mananciais de abastecimento público e a relevância do episódio de rejeição do rio Piracicaba no ano 2000 como principal manancial de abastecimento público do município de mesmo nome, em decorrência da perda de qualidade de suas águas, dos altos custos do tratamento e da impossibilidade de garantir água de consumo humano de qualidade , o trabalho teve por objetivo também analisar as perspectivas para a qualidade das águas do rio Corumbataí, novo manancial eleito para Piracicaba. Utilizou-se como recurso a análise de dados de caracterização física das bacias e sócio-econômica dos municípios das bacias dos rios Piracicaba e Corumbataí, e da qualidade das águas dos rios Piracicaba e Corumbataí. O estudo faz uma reflexão sobre o atual arranjo de instituições públicas, suas atribuições legais e ferramentas para a aplicação de leis e implementação de ações de planejamento regional nas bacias dos rios Corumbataí e Piracicaba. / The Society needs to be able to check when a water source for public supply is about to reach a degradation level. The percentage off forest covered in the watershed can be used as one of the indicators to measure the quality of a public water source. The cost of water treatment from different water supply areas containing different percentage of soil forest cover, is a component that can be brought into discussions about the importance of the forest cover in drinking water public supply areas, as an environmental natural resource, to be prioritized by the Authorities, and mandatory by the Society, heading to both economical benefits and the human health risks minimization. This work has determined the costs of water treatment from water supply areas with different percentages of natural forest cover, analysis of all operating data of all Treatment Water Stations (ETAs), as well as their water sources. For six out of seven studied systems and ETAs, the specific cost with chemical products in one ETA increases with the reduction of the known portion of rain forest for the watershed. Certainly this study was not intended to try to associate the forest location areas to other factors, as for example, the erosion soil characteristic or to the portion of forest cover, located in riparian areas. Considering the focus of this work about the public supply of drinking water and the recent episode of the Piracicaba river rejection as the main water supply for the Region in year 2000, because of the low level quality of its water, the high treatment costs, and the impossibility to make feasible to count on it to distribute good quality water, this work had also the purpose of analyzing the perspectives for the Corumbataí river, to be elected as the main source of water supply for Piracicaba. Socio-economic of all cities along the river basins of Piracicaba and Corumbataí has been studied. Besides the organization of all administrative offices in charge with the problem, their legal functions and possible available tools to plan and to work properly, has also been analyzed.
|
323 |
Avaliação de diversos métodos de detecção de cistos de Giardia spp. e Oocistos de Cryptosporidium parvum presentes no resíduo gerado após o tratamento de água de abastecimento com turbidez elevada / Evaluation of several methods for the detection of Giardia spp. cysts and Cryptosporidium parvum Oocysts in wastes produced after high- turbidity water treatmentGuilherme Lelis Giglio 24 August 2015 (has links)
Este trabalho teve como objetivo avaliar diversos métodos de detecção e recuperação de cistos de Giardia spp. e de oocistos de Cryptosporidium parvum em resíduos gerados no tratamento de águas de abastecimento com turbidez elevada tendo como padrão o Método 1623.1 da USEPA (2012 ). Para tanto, ensaios utilizando aparelho Jarteste (coagulação, floculação, decantação e filtração ) foram realizados utilizando o coagulante cloreto de polialumínio - PAC. Em todos os métodos avaliados foi utilizada a técnica de purificação por separação imunomagnética - IMS. A adaptação do método floculação em carbonato de cálcio FCCa elaborado por Vesey et al. (1993) e adaptado por Feng et al. (2011), repercutiu nos melhores resultados para a amostra de resíduo sedimentado, com recuperações de 68 ± 17 % para oocisto de C. parvum e de 42 ± 7 % para cisto de Giardia spp. Entretanto, as recuperações para a amostra de água de lavagem dos filtros - ALF foram inferiores à 1 %, não sendo possível determinar um método adequado. A presença dos patógenos indica que o reuso da ALF em ETA convencionais ou o descarte em mananciais sem um tratamento prévio, pode representar problemas de contaminação. A adaptação dos métodos de Boni de Oliveira (2012) e Keegan et al. (2008), também repercutiram em porcentagens de recuperação expressivas para a amostra de resíduo sedimentado, sendo de: 41 ± 35 % para oocisto de C. parvum e 11 ± 70 % para cisto de Giardia spp., e 38 ± 26 % para oocisto de C. parvum e 26 ± 13 % para cisto de Giardia spp., respectivamente. A análise estatística não resultou em diferença significativa entre estes dois métodos, entretanto, as elevadas recuperações indicam que estes métodos podem ser melhor avaliados em pesquisas futuras. / This dissertation addresses the evaluation of several methods for the detection of Giardia spp. cysts and Cryptosporidium parvum oocysts in wastes produced after a high-turbidity water treatment, according to Method 1623.1 from USEPA (2012). Coagulant polyaluminium chloride - PACl was used in jar test experiments (coagulation/flocculation, sedimentation and filtration ). The Immunomagnetic Separation - IMS technique was applied to all methods. The calcium carbonate flocculation (CCF) method, developed by Vesey et al. (1993) and adapted by Feng et al. (2011 ), was applied to sludge samples in this research and was the best method tested, with 68% ± 17 % and 42 % ± 7,00 % recoveries for C. parvum oocysts and Giardia spp. cysts, respectively. On the other hand, the percentage recovery of (oo)cysts for filter backwash water samples was lower than 1 % and no suitable method could be detected. The presence of pathogens represents contamination risks for water sources and the reuse of filter backwash water may be a problem to conventional water treatment plants. The application of Boni de Oliveira (2012) and Keegan et al. (2008) methods, adjusted to this study, also resulted in significant percentage recoveries for the sludge samples, with 41 ± 35 % for C. parvum oocyst and 11 ± 70% for cyst Giardia spp., and 38 ± 26% for oocyst C. parvum and 26 ± 13% for cyst Giardia spp., respectively. The statistical analysis showed no significant differences between the two methods, however, such high recoveries indicate they should be better evaluated in future research.
|
324 |
Remoção de microcistina em águas provenientes de reservatório eutrofizado associando técnicas de clarificação, pré-oxidação com permanganato de potássio, adsorção em carvão ativado e pós-cloração / Removal of microcystins in water from eutrophic reservoir involving technical of clarification, pre-oxidation with potassium permanangate, adsorption with powdered activated carbon and post-chlorinationJaqueline Almeida de Oliveira 03 July 2009 (has links)
O presente trabalho teve como objetivo avaliar a remoção de três concentrações diferentes de microcistina extracelular em diferentes combinações de tratamento de águas para abastecimento, em escala de bancada, que tiveram como sequência básica a clarificação associada ou não aos processos de pré-oxidação com \'K\'MN\'O IND.4\', adsorção em CAP e pós-cloração. Os resultados mostraram que para todas as águas estudadas o permanganato de potássio não interferiu nos mecanismos de coagulação/floculação e ainda mostrou-se uma alternativa segura para realização da pré-oxidação no que tange à formação de THMs. Na Fase 1, com concentração inicial de microcistina extracelular em torno de 1,4 \'mü\'g/L, a clarificação (coagulação, floculação, flotação por ar dissolvido e clarificação final) atendeu ao padrão de potabilidade que determina concentrações de microcistina menores que 1,0 \'mü\'g/L. Já na Fase 2, com concentração inicial microcistina extracelular em torno de 21,7 \'mü\'g/L, para o atendimento à legislação foi necessário associar a clarificação à pré-oxidação, dosando-se 1,0 ou 2,0 mg \'K\'MN\'O IND.4\'/L, e à pós-cloração com 3,0 mg \'CL IND.2\'/L. Na Fase 3, com concentração inicial de microcistina extracelular em torno de 64,1 \'mü\'g/L, a associação da clarificação com a adsorção com 60,0 mg/L de CAP e com a pós-cloração com 3,0 mg \'CL IND.2\'/L proporcionou residuais de microcistina extracelular inferiores à 1,0 \'mü\'g/L. Observou-se ainda, que nas Fases 1 e 3 a presença de matéria orgânica dissolvida interferiu negativamente nas sequências de tratamento ao consumir parte do permanganato de potássio destinado à oxidação da microcistina extracelular. Entretanto, na Fase 2 a demanda do pré-oxidante pelas substâncias húmicas parece ter impedido a lise de parte das células de Microcystis sp. / The present work had as objective to evaluate the removal of three different concentrations of extracellular microcystins in different combinations of water treatment for supplying, in bench scale, that had as basic sequence the clarification associated or not with the processes of pre-oxidation with \'K\'MN\'O IND.4\', adsorption on PAC and post-chlorination. The results showed that for all waters studied the potassium permanganate did not interfere in the mechanisms of coagulation/flocculation and also proved to be a safe alternative for achieving the pre-oxidation with regard to the formation of THMs. In Phase 1, with initial concentration of extracellular microcystin around 1.4 \'mü\'g/L, the clarification (coagulation, flocculation, dissolved air flotation and clarification final) met the World Health Organization drinking water guideline value of 1.0 \'mü\'g/L of microcystin. Already, in Phase 2, with initial concentration extracellular microcystin around 21.7 \'mü\'g/L, to meet the legislation was necessary to involved the clarification with the pre-oxidation, dosing 1.0 or 2.0 mg \'K\'MN\'O IND.4\'/L, and with the post-chlorination with 3.0 mg \'CL IND.2\'/L. In Phase 3, with initial concentration of extracellular microcystin around 64.1 \'mü\'g/L, the association of clarification with the adsorption with 60.0 mg/L of PAC and the post-chlorination with 3.0 mg\'CL IND.2\'/L provided residual extracellular microcystin below 1.0 \'mü\'g/L. It was also observed that in Phases 1 and 3 the presence of dissolved organic matter intervened negatively in the sequence of treatment when consuming part of the potassium permanganate destined to the oxidation of extracellular microcystin. However, in Phase 2 the demand for pre-oxidizing by the humic substances seems to have prevented the lysis of some cells of Microcystis sp.
|
325 |
Tratamento de água residuária parcialmente solúvel em reator anaeróbio em batelada seqüencial contendo biomassa imobilizada e agitação mecânica: análise da influência da intensidade de agitação e do tamanho de biopartícula / Treatment of partially soluble wastewater in an anaerobic sequencing batch reactor with immobilized biomass and mechanical stirring: analysis of the influence of agitation rate and bioparticle sizeSamantha Cristina de Pinho 09 June 2004 (has links)
Neste trabalho de doutorado utilizou-se um reator anaeróbio em batelada seqüencial contendo biomassa imobilizada em matrizes cúbicas de espuma de poliuretano e agitação mecânica, com volume total de 5.5 L e volume útil de 4.5 L. A agitação do meio líquido foi realizada com quatro tipos de impelidores (turbina tipo hélice, lâminas planas, lâminas planas inclinadas e lâminas curvas, testados individualmente, sempre em número de 3), com 6 cm de diâmetro. A pesquisa foi realizada em quatro etapas experimentais. A etapa 1 objetivou determinar o tempo de mistura no reator para cada tipo de impelidor, ou seja, o tempo necessário para que o meio líquido ficasse totalmente homogêneo. A etapa 2 objetivou selecionar o tipo de impelidor e a respectiva intensidade de agitação que garantisse a minimização da resistência à transferência de massa externa no sistema. As intensidades de agitação testadas variaram de 200 a 1100 rpm, dependendo do tipo de impelidor. A etapa 3 foi realizada com tipo de impelidor e intensidade de agitação definidos na etapa 2, mas variando-se o tamanho da biopartícula (0,5, 1,0, 2,0 e 3,0 cm de aresta). O objetivo desta etapa foi selecionar o tamanho de biopartícula que minimizasse a resistência à transferência de massa interna. De posse das condições operacionais otimizadas (tipo de impelidor, intensidade de agitação e tamanho de partícula de suporte), a etapa 4 constituiu na aplicação das mesmas para o tratamento de um resíduo real, sendo escolhida água residuária de suinocultura. Na etapa 1, os resultados mostraram que os tempos de mistura para todos os tipos de impelidores foram desprezíveis em relação ao tempo total de ciclo. A etapa 2 revelou tempos de partida muito curtos (cerca de 20 dias), em todas as condições testadas, sendo atingidas remoções de DQO próximas de 70%. Além disso, o tipo de impelidor exerceu grande influência na qualidade final do efluente, fato este claramente constatado quando as frações de DQO foram consideradas separadamente (filtrada e suspensa). De acordo com os resultados obtidos na etapa 3, o tamanho da biopartícula teve influência decisiva no desempenho do sistema, nas condições testadas. As velocidades de dissolução foram aparentemente influenciadas pelo empacotamento do leito de espuma, enquanto que o consumo da fração de DQO correspondente às amostras filtradas foi provavelmente influenciado por fatores mais complexos. Finalmente, o teste realizado com resíduo diluído de suinocultura demonstrou que a operação do reator em estudo para o tratamento deste tipo de água residuária é possível. Os dados operacionais mostraram que o reator permaneceu estável durante o período testado. A agitação mecânica provou ser eficiente para melhorar a degradação da DQO suspensa, um dos maiores problemas no tratamento deste tipo de água residuária. Sendo assim, de acordo com os dados experimentais obtidos ao longo do trabalho, pode-se afirmar que a agitação em reatores em batelada mostrou-se importante não somente para proporcionar boas condições de mistura ou melhorar a transferência de massa na fase líquida, mas também para melhorar a solubilização da matéria orgânica particulada, melhorando as velocidades de consumo de matéria orgânica. / The bench-scale anaerobic sequencing batch reactor containing immobilized biomass and provided with mechanical stirring employed in this work had total and useful volumes of 5.5 and 4.5 L, respectively. The biomass was immobilized on cubic polyurethane foam matrices, and the agitation of the liquid medium was provided by four types of impellers (propeller, flat-blade, pitched-blade and curved-blade turbines, individually tested, always in a set of three), with 6 cm of diameter. The research was divided into 4 experimental steps. The first one aimed at determining the mixing time in the reactor for each sort of impeller, i.e., the time necessary for the system to be completely homogeneized. As for the second step, its objective was to choose the sort of impeller and the agitation rate suitable for minimizing the external mass-transfer resistance. The agitation rates tests ranged from 200 to 1100 rpm, depending on the impeller type. The step 3 was carried out utilizing the chosen impeller and agitation rate, but varying the bioparticle size (0.5, 1.0, 2.0 and 3.0 cm of side). The aim of these experiments was to determine the bioparticle size that minimized the solid-phase mass transfer. Using these optimized operational conditions (type of impeller and bioparticle size), the step 4 consisted of the utilization of them in the treatment of a real wastewater (diluted swine manure). As for the results, step 1 showed the mixing times were very low compared to the total cycle times employed in the experiments (8 and 24 h). Very short start-up periods were revealed by the second experimental part (about 20 days in average) for all conditions tested, and the removal efficiencies reached approximately 70%. Besides that, the impeller type exerted great influence on the final quality of the effluent, fact clearly observed when the COD fractions were analyzed separately (filtered and suspended). According to the data obtained in the step 3, the bioparticle size influenced decisively on the performance of the system, in the conditions tested. The bed packing apparently influenced the dissolution rates, whereas the consumption of the COD correspondent to the filtered samples was defined by more complex factors. Finally, the test with the diluted swine manure demonstrated that the operation of this reactor with this type of wastewater is feasible, as the operational data showed the reactor remained stable during all the period tested. The mechanical stirring proved to be efficient to improve the degradation of the suspended COD, one of the major problems in the treatment of this type of wastewater. In this sense, according to the experimental data obtained in this work, it can be affirmed the mechanical stirring in anaerobic sequencing batch reactors showed to be not only important to provide good mixing conditions and improve the liquid phase mass transfer, but also to improve the solubilization of the particulate organic matter and increase the overall organic matter consumption rates.
|
326 |
Incorporação de lodo gerado na Estação de Tratamento de Água Tamanduá, como ativo em massas para cerâmica vermelha / Incorporation of sludge generated in the Tamanduá Water Treatment Plant Incorporated, with addition of a red ceramic massTartari, Rodrigo 05 December 2008 (has links)
Made available in DSpace on 2017-07-10T18:08:09Z (GMT). No. of bitstreams: 1
Rodrigo Tartari.pdf: 9550409 bytes, checksum: 139b195eb1b11dbe7bfc7a238de6d98b (MD5)
Previous issue date: 2008-12-05 / The objective of this work is to research the development of methods for utilizing the sludge generated in the Tamanduá water treatment plant, located in the city of Foz do Iguaçu - PR, as a prime material for the production of red ceramic. For this purpose, it was used beyond the mud, four clays originating geological region of western Paraná, called: Plastic (OP) and Sand (AO) from Santa Rita Ceramic and Plastic (AP) and Sand (AA) from de Artisans Cooperative of Foz do Iguaçu PR (COOAFOZ), used for production of red ceramic. The methodology is divided into: characterization of the 5 materials for determination of humidity, organic matter, loss by fire, limits of sil consistency, residues, grain fineness, chemical and mineralogy, in the second phase of the investigation, seven
binary mistures were made among the clays from Santa Rira Cermics and from COOAFOZ, varying the weight of both in proportion of 0, 30, 40, 50, 60, 70 and 100%. Were up 336
bodies of evidence by uniaxial pressing, tested dry and after sintering at temperatures of 950 o and 1050 °C, measured before the following tests: total linear contraction, water absorption, apparent porosity, loss by fire, apparent specific mass, strength the bending, scanning electron microscopy and microanalysis. It was found that the clay AP and OP showed characteristics
of high plasticity with major composition of SiO2, Al2O3 and Fe2O3 and grains < 2μ equivalent to 19.4 and 21.6, respectively. When these clays the AP and OP in greater weight percentages in the mixtures, the intensities of interaction between clay processing were positively evaluate the physical-mechanical properties of bodies of evidence. Mixtures A1 (100% AP), A2 (70% AP + 30% AA), B1 (100% AP) and A2 (70% AP + 30% AA), showed better results on water absorption of less than 25% and resistance to bending than 60 kgf/cm2 at a temperature of 950 °C and more than 80 kgf/cm2 to 1050 oC. In these compositions, is
incorporated 4, 8, 12 and 16% of dry sludge to determine the maximum permissible load without causing cracks and deformations. It was found that the sludge presented
characteristics of silty clay of low plasticity, can replace clay similar to 8% in the production of red ceramic. According to analysis of results, have been building blocks of 6 holes for the method of extrusion incorporating 8% of wet mud is found that the physical mechanical properties evaluated were: linear contraction of 8.6%, 24% water absorption and 46 kgf /cm2 of resistance to compression, and within the rules for production of red ceramic coating for (bricks). It appears that the sludge was incorporated as the mass of wet clay, about 75% of
initial water when received from the water treatment plant Tamanduá, contributing to process of maturation. It was concluded that based on the results obtained in the laboratory that the sludge generated in the water treatment plant of the unit Tamanduá in Foz do Iguaçu - PR can be used
as an additive in the manufacture of bodies for red ceramic. / Este trabalho tem por objetivo pesquisar o desenvolvimento de métodos para utilizar o lodo gerado na Estação de Tratamento de Água Tamanduá, localizada na cidade de Foz do
Iguaçu/PR, como matéria-prima para produção de cerâmica vermelha. Para atingir a finalidade proposta, utilizaram-se além do lodo, quatro argilas de formação geológica da
região oeste do Paraná, denominadas por: Plástica (OP) e Areia (OA) da Cerâmica Santa Rita e Plástica (AP) e Areia (AA) da Cooperativa de Artesões de Foz do Iguaçu PR (COOAFOZ), empregadas para produção de cerâmica vermelha. A metodologia subdividiu-se em: caracterização das 5 matérias-primas pela determinação da umidade, matéria orgânica, perda
ao fogo, limites de consistência de solos, resíduos, granulometria, composição química e mineralógica. Na segunda fase da investigação, fez-se sete misturas binárias entre as argilas da Cerâmica Santa Rita e da COOAFOZ, variando o peso de ambas em 0, 30, 40, 50, 60, 70 e 100%. Foram confeccionados 336 corpos de prova por prensagem uniaxial, analisados a seco e após sinterização nas temperaturas de 950 e 1050 oC, avaliados perante os seguintes ensaios: contração
linear total, absorção de água, porosidade aparente, perda ao fogo, massa específica aparente, resistência à flexão, microscopia eletrônica de varredura e microanálise. Verificouse
que as argilas AP e OP apresentaram características de alta plasticidade com presença majoritária de SiO2, Al2O3, e Fe2O3 e grãos < 2μ, iguais a 19,4 e 21,6 respectivamente. As argilas
AP e OP em maiores porcentagens peso nas misturas intensificaram as interações entre os argilominerais, isto é, no processamento obtiveram-se resultados positivos diante a
avaliação das propriedades físico mecânicas dos corpos de prova. As misturas A1 (100% AP), A2 (70% AP + 30% AA), B1 (100% OP) e B2 (70% OP + 30% OA), apresentaram melhores
resultados com relação à absorção de água menor que 25% e resistência à flexão superior a 60 kgf/cm2 na temperatura de sinterização a 950 oC e superior a 80 kgf/cm2 à 1050 oC. Nestas composições, incorporaram-se 4, 8, 12 e 16% de lodo seco para determinar a carga máxima admissível sem causar trincas e deformações. Verificou-se que o lodo apresentou
características de argilas siltosas de baixa plasticidade, podendo substituir argilas similares em até 8% na produção de cerâmica vermelha. De acordo com análise dos resultados obtidos, fizeram-se blocos estruturais de 6 furos pelo método de extrusão incorporando 8% de lodo úmido, e verificou-se que as propriedades físico-mecânicas avaliadas foram as seguintes:
8,6% de contração linear, 24% de absorção de água e 46 kgf/cm2 de resistência à compressão, estando dentro das normas de produção de cerâmica vermelha para revestimento (tijolos). Destacou-se que o lodo incorporado na forma úmida à massa de argila, com cerca de 75% de água inicial quando recebido da Estação de Tratamento de Água Tamanduá, contribuiu no processamento de maturação da mesma. Portanto, conclui-se com base nos resultados que o lodo gerado na Estação de Tratamento de Água da unidade Tamanduá em Foz do Iguaçu PR pode ser utilizado como aditivo na fabricação de massas para cerâmica vermelha.
|
327 |
Influência do tempo de detenção hidráulica e do gradiente médio de velocidade na zona de contato no desempenho de unidade piloto de flotação por ar dissolvido aplicado à clarificação de água para abastecimento / Influence of hydraulic detention time and velocity gradient in the contact zone on the performance of unit pilot dissolved air flotation clarification applied to potable waterKaren Soraia Meca 03 October 2014 (has links)
O desempenho de unidades de flotação por ar dissolvido (FAD) depende significativamente do projeto da zona de contato (ZC) dessas unidades, situada na entrada das mesmas e responsável por promover condições adequadas para que ocorram taxas satisfatórias de colisão entre as microbolhas de ar e os flocos formados na etapa antecedente de floculação da água para abastecimento. Os dois principais parâmetros de projeto da ZC são o tempo de detenção hidráulico ou tempo de contato (Tzc) e o gradiente médio de velocidade na ZC (Gzc). A presente dissertação apresenta os resultados de estudo sobre a influência do Tzc e do Gzc na ZC de uma unidade piloto de flotação por ar dissolvido (UPFAD) com escoamento contínuo aplicada ao tratamento de água para abastecimento. Foram utilizados módulos contendo tela metálica em seu interior com malha de #25 mm com diferentes dimensões, de modo a se obterem diferentes valores de Gzc e Tzc. Foram investigadas duas configurações na unidade de FAD (Configurações A e B), nas quais o comprimento (Lzc) e a altura (Hzc) da ZC foram variados, permitindo a alteração do Tzc e mantendo-se controlados os valores de Gzc (com a introdução ou não de diferentes módulos de tela metálica na ZC) e vice versa. Os demais parâmetros do processo de FAD não sofreram variações, tais como taxa de aplicação superficial (TAS) na zona de separação, tempo de floculação, entre outros. Para a configuração A, foram estudadas três alturas diferentes na ZC e para a configuração B, quatro alturas diferentes na ZC, o que acarretou, para cada valor de Gzc variação do Tzc. Para cada configuração da ZC, também foram testados três valores de vazão de recirculação de água saturada com ar de modo a se obterem três diferentes concentrações de ar (A/V) no processo de flotação. Para todos os parâmetros analisados (Turbidez, Cor, Absorbância), as maiores eficiências de remoção foram obtidas nos ensaios realizados com o uso da tela #25 mm tanto na configuração A (TASzc = 136 m/h e G = 6,1 s-1) quanto na configuração B (TASzc = 87 m/h e G = 3,2 s-1). Os resultados permitem concluir que o par de valores (Tzc, Gzc) é mais apropriado para o projeto da zona de contato de unidades FAD do que o par (Tzc, TASzc) usualmente adotado pelos projetistas, sendo que, na faixa de valores investigados a UPFAD apresentou melhor desempenho para o par: Tzc de 41 s e Gzc de 6,1 s-1. / The performance of units dissolved air flotation (DAF) depend significantly of design on the contact zone (CZ) of these units, situated at the entrance thereof and responsible for promoting appropriate conditions to occur satisfactory collision rates between air microbubbles and the flocs formed in the step of flocculation of potable water. The two main design parameters of the CZ are the hydraulic detention time or contact time (Tcz) and the velocity gradient in the CZ (Gcz). This work presents the results of study of the effects of varying the Tcz and Gcz at the contact zone of pilot unit DAF with continuous flow applied to the treatment of potable water. Were used modules containing metal grille with mesh of #25 mm, with different dimensions in order to obtain different values of Gcz and Tcz. Were investigated two configurations in the unit FAD ( configurations A and B) where the length (Lcz) and height (Hcz) of contact zone were varied, allowing the variation of Tzc and keeping the values of Gcz controlled (with the introduction or not of different modules in the metal grille in CZ) and vice versa, without changes in other process variables FAD, such as rate of surface application (TAS) in the separation zone, flocculation time, among others. For the configuration A were studied three different heights in the CZ and in configuration B, four different heights in the CZ, which resulted, for each value of Gcz (relative to the chosen value of Lcz) the variation of Tzc. For each configuration of CZ were also tested three values of recirculation flow of air saturated in order to obtain three different values of concentration in air (A/V) in the flotation process. For all parameters analyzed (turbidity, color, absorbance), the highest efficiencies were obtained in assays performed using the grille #25 mm, both in configuration A (TAScz = 136 m/h and L = 6,1 s-1) and configuration B (TAScz = 87 m/h and G = 3,2 s-1). The results indicate that the pair of values (Tcz, Gcz) is more suitable for project of the CZ of units FAD than the pair (Tcz, TAScz) usually adopted by the designers, and values in the range investigated in UPFAD showed performed better for Tcz of 41 s and Gcz of 6,1 s-1.
|
328 |
Influência do gradiente médio de velocidade na zona de contato na eficiência de clarificação de água para abastecimento por flotação / Influence of the velocity gradient in the contact zone in the efficiency of clarification of potable water by flotationIrene Monteiro da Franca Souza 13 September 2012 (has links)
O presente trabalho teve como objetivo estudar a influência do gradiente médio de velocidade (Gzc), associado ao tempo de detenção hidráulico (tzc) e à taxa de aplicação superficial (TASzc), na zona de contato, na eficiência de clarificação de uma unidade retangular de flotação por ar dissolvido, em escala piloto, tratando água para abastecimento. Foram estudadas duas configurações da Unidade Piloto de Flotação por Ar Dissolvido (UPFAD) (A e B), as quais diferem no comprimento da zona de contato A (90 mm) e B (140 mm). A TASzc - A (133 ± 3 m/h) e B (86 ± 1 m/h) - e o tzc - A (54 ± 1s) e B (84 ± 1 s) - são diferentes. Foram avaliados três valores do Gzc A (1,8; 6,5;10,2) e B (0,9; 4,7; 6,3), através da inserção de telas com características diferentes no interior da zona de contato. E, Para cada valor de Gzc, foram investigados três valores de A/V (3,73; 4,90; 6,41). Em todos os ensaios realizados, foram fixados os seguintes parâmetros: vazão da água bruta preparada (5,4 m³/h); temperatura da água bruta preparada (26 ± 1ºC); pH de coagulação (6,5 ± 0,1); tempo de floculação (17,2 min); gradiente médio de velocidade de floculação (110 s-1); vazão de descarte após a floculação (0,8 m³/h); vazão de entrada para a flotação (Qe) (4,6 m³/h); velocidade de entrada para a flotação (ve) (180 m/h); velocidade cross-flow (45 m/h); TASzs (14,6 ± 0,2 m/h); pressão de saturação (4,5 ± 0,1 Kgf/cm²). A unidade piloto FAD foi alimentada com água preparada, que apresentou turbidez em torno de 7,4 ± 0,6 UNT, e cor aparente, em torno de 39,4 ± 4,3 UH. A fração removida dos parâmetros analisados para cada Gzc é menos sensível a variações de A/V na configuração A que na configuração B. Na configuração A, a tela que apresentou Gzc em torno de 6,5 s-1 gerou melhores resultados para cada A/V analisado. Na configuração B, a tela que gerou Gzc em torno de 4,7 s-1 proporcionou melhor fração removida de turbidez e cor para cada A/V estudado. Além disso, na configuração B, a fração removida de turbidez e cor foi menos sensível a variações de A/V, para Gzc de 4,7 s-1 que para os demais valores de Gzc. A tela que gerou resultados mais eficientes na configuração A foi a mesma para a configuração B. Portanto o uso da referida tela favoreceu o desempenho das configurações A e B. Comparando todas as situações estudadas nas duas configurações, o ensaio com a configuração A (com tzc de 54 s) com Gzc de 6,3 s-1 e A/V de 4,9 g/m³, apresentou as maiores frações de remoção de cor e turbidez. / The present work aimed to study the influence of velocity gradient (Gzc) associated with the hydraulic detention time (tzc) and the rate of surface application (TASzc) in the contact zone in the efficiency of clarification of a unit rectangular dissolved air flotation pilot scale, treating water supplies. Two different kinds of configurations of the reactor dissolved air flotation in pilot scale (UPFA) (A and B) were studied, which differ in the length of the contact zone - A (90 mm) and B (140 mm). The TASzc - A (133 ± 3 m/h) and B (86 ± 1 m/h) - and tzc - A (54 ± 1 s) and B (84 ± 1 s) were different. Three different values of Gzc were analysed - A (1.8, 6.5, 10.2 s-1) and B (0.9, 4.7, 6.3 s-1) by insertion of grilles with different characteristics within the zone contact. And for each value of Gzc, three values of A/V (3.73, 4.90, 6.41 g/m³) were investigated. In all trials, the following parameters were set: flow of synthetic raw water (5.4 m³/h), synthetic raw water temperature (26 ± 1ºC), coagulation pH (6.5 ± 0.1); flocculation time (17.2 minutes), the speed gradient flocculation (110 s-1); flow disposal after flocculation (0.8 m³/h), input flow to the flotation (Qe) (4, 6 m³/h), input speed for flotation (ve) (180 m/h), cross-flow velocity (45 m/h), TASzs (14.6 ± 0.2 m/h), saturation pressure (4.5 ± 0.1 kgf/cm ²). The pilot plant was fed with synthetic water, which showed turbidity of approximately 7.4 ± 0.6 NTU, and apparent color, about 39.4 ± 4.3 HU. The removal efficiency of the analyzed parameters for each Gzc is less sensitive to variations in the A/V in the configuration A than in the configuration B. In configuration A, the grille that showed Gzc about 6.5 s-1 gave better results for each A/V analysis. In configuration B, the grille that has generated Gzc around 4.7 s-1 provided the best removal efficiency of turbidity and color for each A/V studied. Furthermore, in the configuration B, the removal efficiency of color and turbidity was less sensitive to variations in A/V for Gzc 4.7 s-1 than for other values of Gzc. The grille that generated the best results in the configuration A was the same for the configuration B. Therefore the use of that grille favored the performance of configurations A and B. Comparing all the situations studied in two configurations, the test with the configuration A (with tzc the 54 s) with Gzc of 6.3 s-1 and A/V of 4.9 g/m³, had the highest removal efficiencies of color and turbidity.
|
329 |
Remoção de células e subprodutos de Microcystis spp. por dupla filtração, oxidação e adsorção / Removal of cells and by-products of Microcystis spp. in double filtration, oxidation and adsorption processesEmília Kiyomi Kuroda 18 December 2006 (has links)
Considerando o aumento da ocorrência de florações de cianobactérias e a possibilidade de formação de subprodutos em diversos mananciais destinados ao consumo humano, este trabalho teve como objetivo, avaliar a remoção de células e subprodutos de Microcystis spp. pelos processos de dupla filtração com filtração ascendente em pedregulho e de filtração descendente em areia, oxidação e adsorção com carvões ativados pulverizado e granular. Na fase 1 foram realizados ensaios de bancada para estabelecimento das condições operacionais dos ensaios a serem realizados em instalação piloto, utilizando-se água de estudo preparada com adição de cultura de cepa tóxica de Microcystis spp. e ou extrato de microcistinas. Em seguida, foram realizados ensaios em instalação piloto de escoamento contínuo para águas de estudo preparadas com adição de cultura de cepa tóxica de Microcystis spp. e de extrato de microcistinas fase 2 e de material coletado no reservatório de Barra Bonita SP - fase 3. A concepção de dupla filtração utilizada mostrou ser bastante eficiente na remoção de células de Microcystis spp. e, consequentemente, de microcistinas intracelulares, porém, a remoção ou degradação de microcistinas extracelulares só foi significativa com o emprego de processos complementares de oxidação e ou adsorção. Para as águas de estudo empregadas, não houve formação expressiva de subprodutos organohalogenados nos efluentes dos processos de tratamento, após serem submetidas à cloração e tempo de contato de 1 dia. Adicionalmente, foram realizados estudos prospectivos no sentido de avaliar a toxicidade de extrato, águas de estudo e efluentes dos processos de tratamento por meio de bioensaios com cladóceros e camundongos, além de biomonitoramento com a espécie de peixe Danio rerio. / Considering the increase in the frequency of cyanobacterial blooms and the possibility of by-product formation in water supply sources for human consumption, this work was carried out in order to evaluate the removal of cells and by-products of Microcystis spp. using the processes of double filtration (gravel upflow filtration of coagulated water followed by rapid sand downflow filtration), oxidation and adsorption in powdered and granular activated carbons. Bench scale assays were performed in phase 1 to determine the operational conditions of the tests to be performed in a continuous flow pilot plant, using a study water prepared with filtered water in the water treatment plant 2 of Sao Carlos and culture of a toxic strain of Microcystis spp. and/or microcystins extract. Based on the conditions stated in phase 1, phase 2 was carried out by performing tests in the pilot plant for study waters prepared with culture of toxic strain of Microcystis spp. and phase 3 of microcystins extract from material collect in the de Barra Bonita SP reservoir. The double filtration system used resulted very efficient concerning the removal of cells of Microcystis spp., but, on the other hand, the removal or degradation of extracellular microcystins was significant with the use of complementary processes such as oxidation and or activated carbon adsorption. With regards to the waters studied, there wasnt significant formation of by-products due to the oxidation of the effluent of each combination of processes, when submitted to chlorination with detention time of 1 day. Additionally, it was observed the toxicity effect by bioassays with crustaceans and mices, besides Danio rerio fish screening.
|
330 |
Remoção de Giardia spp. e Cryptosporidium spp. em águas de abastecimento com turbidez elevada utilizando cloreto de polialumínio: estudo em escala de bancada e desafios analíticos / Giardia spp. Cysts and Cryptosporidium spp. Oocysts removal in high turbid drinking water using polyaluminum chloride: a bench scale study and analytical challengesPaulo Marcos Faria Maciel 22 August 2014 (has links)
O objetivo deste trabalho foi avaliar o desempenho da remoção de cistos deGiardia spp. e oocistos de Cryptosporidium parvum, em águas de abastecimento com turbidez elevada, em experimentos em escala de bancada (coagulação, floculação, decantação e filtração). Para tanto, empregou-se o coagulante cloreto de polialumínio – PAC. O método de filtração em membranas foi adotado para a concentração de protozoários, seguido ou não da etapa de purificação por separação imunomagnética – IMS. Os métodos foram avaliados em experimentos de controle de qualidade analítica e o método sem IMS apresentou as seguintes porcentagens de recuperação, 80% ±16,32% para cistos de Giardia spp. e 5% ±10,00% para oocistos de C. parvum. O método com IMS apresentou 31,5%±7,55% de recuperação para cistos de Giardia spp. e 5,75%±3,20% de recuperação para oocistos de C. parvum. Os experimentos demonstraram que não houve melhora na remoção de ambos os protozoários na condição de maior dosagem de coagulante (65 mg.L-1 de PAC e pH 7,29). A condição de menor dosagem de coagulante (25 mg.L-1 de PAC e pH 6,76) apresentou um desempenho melhor, ao contrário de uma expectativa de que a maior dosagem de coagulante pudesse favorecer a remoção destes microrganismos. A condição de menor dosagem apresentou, na água filtrada, 50 e 75% de ausência de identificação de cistos de Giardia e oocistos de C. parvum, respectivamente. A condição de maior dosagem apresentou (oo)cistos na água filtrada de todas amostras analisadas. Estes resultados indicam a importância do controle da coagulação na remoção de protozoários. / The aim of this study was to evaluate the performance of Giardia spp. cysts and Cryptosporidium parvum oocysts removal in a bench scale experiment. The coagulant polyaluminium chloride – PACl was used in this research. The protozoa concentration tests were performed by applying the Membrane Filtration method, with and without Immunomagnetic Separation assay-IMS. The methods were evaluated using control experiments and the method without IMS had the following percentage recovery, 80% ± 16.32% and 5% ±10.00% for Giardia cysts and C. parvum oocysts, respectively. The method with IMS presented 31.5% ± 7.55% and 5.75% ± 3.20% of percentage recovery for Giardia cysts and C. parvum oocysts, respectively. Bench scale experimental results have clearly shown that there was no improvement in protozoa removal using the superior dosage of coagulant. The inferior dosage condition (25 mg.L-1 of PACl and pH 6,76) performed better, which was contrary to what was expected in which a superior dosage of coagulant could favour when removing microorganisms. The inferior dosage condition presented 50% and 75% of absence of Giardia cysts and C. parvum oocysts in the final water, respectively. The second coagulation condition (65 mg.L-1 of PACl and pH 7,29) presented protozoa (oo)cysts in the final water of all the samples examined. These results indicate the importance of coagulation control in protozoa removal.
|