• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • Tagged with
  • 32
  • 32
  • 22
  • 17
  • 9
  • 9
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Produção de biogás a partir de vinhaça concentrada / Biogas production from concentrated vinasse

Rubens Perez Calegari 24 February 2017 (has links)
O Brasil é o segundo maior produtor de etanol do mundo. Na safra 2015/16, foram produzidos 30,4 bilhões de litros. Na produção de etanol realizada no Brasil é gerado grande volume de vinhaça, cerca de 10 a 13 litros desse resíduo por litro de etanol produzido. Isso significa uma produção anual de cerca de 300 bilhões de litros desse material residual. Em função disso e do risco de contaminação ambiental por esse material, há necessidade de reduzir o volume desse resíduo. Com isso minimizar o custo com a gestão desse passivo ambiental. Isso pode ser feito mediante a concentração da vinhaça. Além disso, o mercado de energia elétrica tem se apresentado com uma boa oportunidade para o setor sucroenergético. Por esses motivos, o objetivo deste projeto foi a produção de metano a partir do uso de vinhaça concentrada. Para tal, a vinhaça concentrada foi obtida em uma usina no Estado de São Paulo que utiliza concentrador de vinhaça de múltiplos efeitos. Utilizaram-se dois reatores (R1 e R2) do tipo UASB (reator anaeróbio de fluxo ascendente e manta de lodo) com capacidade para 50 L e volume reacional de 34,5 L cada. Os reatores foram operados à 38 ºC, com tempo de detenção hidráulica de 24 horas por 103 dias. O reator R1 recebeu cargas orgânicas volumétricas (COV) crescentes durante 9 fases (3,94; 3,5; 3,89; 4,66; 4,94; 5,33; 5,66; 6,08; 6,38 e 8,96 g DQO (L d)-1), com DQO afluente variando de 23.927 mg L-1 a 44.060 mgL-1. O reator R2 operou como tratamento controle, com COV variando entre 3,83 e 4,32 g DQO (L d)-1. A avaliação do processo de biodigestão anaeróbia foi realizada com base na produção de biogás, eficiência de remoção de DQO, pH, alcalinidade, concentração de ácidos voláteis totais (AVT), concentração de sólidos no lodo e atividade metanogênicas específica do lodo (AME). R1 mostrou-se mais eficiente, com pH e alcalinidade dentro da faixa ideal e efluente com menor concentração de AVT. O desempenho do processo mostrouse estável, atingindo eficiência máxima de remoção de DQO de 90% em R1. A maior produção volumétrica de biogás ocorreu concomitantemente com a maior produção específica de biogás, quando a DQO afluente foi de 42.003 mg L-1, a produção volumétrica de biogás foi de 135,24 L dia-1, e a produção de biogás em relação a DQO removida foi de 0,362 LbiogásgDQOremov-1. No fim do experimento, a AME de R1 foi de 1,19 gDQOCH4 gSTV.d-1, 40% superior a R2, que teve 0,85 gDQOCH4 gSTV.d-1. A alta eficiência de remoção de matéria orgânica e produção de biogás no reator alimentado com alta concentração de DQO foi obtida através da adaptação gradual do consórcio microbiano. / Brazil is the second largest producer of ethanol in the world. In the 2015/16 crop, 30.4 billion liters were produced. In Brazil\'s ethanol production, a large volume of vinasse is generated, about 10 to 13 liters of this residue per liter of ethanol produced. This means an annual output of about 300 billion liters of this waste material. Because of this and the risk of environmental contamination by this material, there is a need to reduce the volume of this waste. This will minimize the cost of managing this environmental liability. This can be done by concentrating the vinasse. In addition, the electricity market has presented itself with a good opportunity for the sugar-energy sector. For these reasons, the objective of this study was to produce methane from concentrated vinasse. For this purpose, concentrated vinasse was obtained from a mill that uses a multi-purpose vinasse concentrator in São Paulo State. Two reactors (R1 and R2) of UASB type (up-flow anaerobic sludge blanket) with capacity for 50 L and reactional volume of 34.5 L each one. The reactors were operated at 38 °C, with hydraulic retention time of 24 hours for 103 days. The reactor R1 received increasing organic load rate (OLR) during 9 phases (3.94, 3.5, 3.89, 4.66, 4.94, 5.33, 5.66, 6.08, 6.38 And 8.96 g COD (L d)-1), with affluent COD ranging from 23,927 mg L-1 to 44,060 mg L-1. The R2 reactor was operated as a control treatment, with OLR ranging from 3.83 to 4.32 g COD (L d)-1. The evaluation of the anaerobic biodigestion process was carried out based on biogas production, COD removal efficiency, pH, alkalinity, total volatile acid concentration (TVA), sludge solids concentration and sludge specific methanogenic activity (SMA). R1 showed to be more efficient, with pH and alkalinity within the ideal range and effluent with lower concentration of TVA. The process performance was stable, achieving maximum COD removal efficiency of 90% in R1. The higher volume of biogas production occurred concurrently with the higher specific biogas production, when the COD was 42.003 mg L-1, the volumetric biogas production was 135.24 L day-1, and the biogas production in relation to removed COD was 0.362 Lbiogas gCODremoved -1. At the end of the experiment, the SMA of R1 was 1.19 gCODCH4 gTVS.day-1, 40% higher than R2, which had 0.85 gCODCH4 gTVS.day-1. The high efficiency of organic matter removal and biogas production in the reactor fed with high COD concentration was obtained through the gradual adaptation of the microbial consortium.
12

Corantes como importante classe de contaminantes ambientes - um estudo de caso / Dyes as an important class of environmental contaminants - a case of study

Oliveira, Danielle Palma de 01 March 2005 (has links)
As amostras ambientais coletadas na área do Ribeirão dos Cristais, região metropolitana de São Paulo, apresentaram atividade mutagênica sistemática durante os últimos anos. De acordo com estudos já publicados em literatura, essa contaminação estava relacionada ao lançamento de efluentes líquidos de uma indústria de tingimento neste corpo d água. Essa indústria tinge principalmente nylon e poliéster, utilizando em seus processos azo corantes dispersos, entre outros. Os corantes de um produto comercial preto (BDCP), muito empregado por essa indústria, foram detectados recentemente em amostras ambientais coletadas nesse local e se mostraram pelo menos parcialmente, responsáveis pela mutagenicidade mencionada. Esses corantes foram identificados como c.I. Disperse Blue 373, C.I. Disperse Violet 93 e C.I. Disperse Orange 37. A água tratada proveniente do Ribeirão dos Cristais também mostrou atividade mutagênica e esta foi relacionada tanto à presença de nitrocompostos aromáticos, incluindo policíclicos, quanto de produtos mutagênicos secundários formados durante a desinfecção. Este trabalho teve como objetivos a caracterizaçãoquímica de amostras de efluente bruto e tratado, provenientes da indústria de tingimento, lançados no Ribeirão dos Cristais; a avaliação da presença dos corantes c.I. Disperse Blue 373, C.I. Disperse Violet 93 e c.I. Disperse Orange 37 em amostras de sedimento antes e após o lançamento; e a verificação da possível formação de compostos mutagênicos incolores, provenientes dos corantes, a partir do processo de cloração, os quais poderiam explicar a mutagenicidade da água tratada. As amostras de efluente bruto e tratado foram analisadas por Cromatografia em Camada Delgada (CCD) e os corantes do produto comercial preto (BDCP) foram detectados, dentre outros. Quando analisadas por Cromatografia em Fase Gasosa! Espectrometria de Massas (CG/EM) foram detectadas, preliminarmente, várias aminas aromáticas mutagênicas, dentre elas alguns produtos de clivagem dos corantes identificados. Os resultados indicaram que o tratamento empregado pela indústria (sistema de lodos ativados) não é eficiente na remoção desses compostos. Nas amostras de sedimento do Ribeirão dos Cristais, coletadas após o lançamento da indústria de tingimento, foram detectados por CCD o corante C.I. Disperse Blue 373 e o c.I. Disperse Orange 37, porém o corante violeta (C.I. Dispersse Violet 93) não foi detectado. A mutagenicidade das mesmas amostras foi avaliada com a linhagem YGI041 de Salmonella, com e sem S9 e a atividade mutagênica detectada pôde ser explicada pela presença dos corantes nas amostras avaliadas. Tendo em vista que nas amostras de água tratada não foram detectados corantes, porém foi observada atividade mutagênica relacionada à presença de nitrocompostos, submeteu-se uma solução do produto comercial BDCP, em concentração compatível com aquela detectada na água bruta, à cloração em condições similares àquelas realizadas pela Estação de Tratamento de Água (ETA). Após a cloração, foi verificada a formação de substâncias incolores, com atividade mutagênica e perfil cromatográfico semelhante ao apresentado por amostras de água tratada coletadas na saída da ETA. Desta forma, especula-se que as substâncias geradas possam estar relacionadas com a mutagenicidade detectada na água tratada. Os resultados obtidos neste trabalho demonstram que corantes azóicos e seus produtos relacionados são uma importante classe de contaminantes ambientais que deveriam ser melhor avaliados toxicologicamente, especialmente quanto a sua atividade genotóxica e carcinogênica tendo em vista o risco direto e indireto de exposição humana à esses compostos quando liberados para o meio ambiente. / Enviromnental samples collected at Cristais river area in the metropolitan region of São Paulo, had showed repeated mutagenic activity during the last years. According to published studies, this contamination was related to the discharge of a dye processing plant. This industry dyes mainly nylon and polyester, using azo disperse dyes, among others. Recently, the dye components of a black dye commercial product (BDCP), widely used by this industry, were detected in enviromnental samples collected in this area and were considered responsible, at least in part, for the cited mutagenicity. These dyes were identified as: C.I. Disperse Blue 373, C.I. Disperse Violet 93 and C.I. Disperse Orange 37. The drinking water from the Cristais river also showed mutagenic activity related to the presence of nitro aromatic compounds, including polycyclic ones, as well as the usual disinfection by products. The objectives of this work were: the chemical characterization of raw and treated effluent samples from the dye processing plant that discharges its effluent in Cristais river; the evaluation of the presence of C.I. Disperse Blue 373, c.I. Disperse Violet 93 and c.I. Disperse Orange 37 in sediment samples before and after the discharge; and the evaluation of the possible generation of non-colored mutagenic compounds, derived from the dyes, during the disinfection step that could explain the mutagenicity of the drinking water. The raw and treated effluent samples were analyzed using Thin Layer Chromatography (TLC) and the dye components of the BDCP were detected, among others. Several mutagenic aromatic amines, including cleavage by-products of the detected dyes, were preliminary detected using gas chromatography/ mass spectrometry (GC/MS). The results demonstrated that the treatment applied by the industry (activated sludge) was not efficient in the removal of theses compounds. In the Cristais river sediment samples collected downstream the dye processing plant discharge, we detected the dyes C.I. Disperse Blue 373 and C.I. Disperse Orange 37 using TLC, however, the violet component (C.I. Disperse Violet 93) was not detected. The mutagenicity of these samples were evaluated using the strain YG1041 of Salmonella, in the presence and absence of S9 and the mutagenic activity observed could be explained by the presence of the dyes in the samples. Taking into account that dyes were not detected in drinking water samples, but the samples showed mutagenicity related to the presence of nitrocompounds, a solution of the commercial product (BDCP), at similar concentration found in raw water, was chlorinated using the Drinking Water Treatment Plant (DWTP) conditions. After the chlorination, the formation of non-colored substances was verified, and these compounds showed mutagenic and chromatographic profiles similar to the drinking water collected at DWTP. In this sense, we suggest that the generated substances could be related to the mutagenic activity previously detected in the drinking water. The results obtained in this study demonstrated that azo dyes and related compounds are an important class of environmental contaminants that should be better evaluated in relation of its toxicity, mainly in relation to their genotoxic and carcinogenic effects, considering the direct and indirect human exposure risk associated to these compounds once in the environrnent.
13

Ozonização catalítica do chorume proveniente do aterro sanitário de Cachoeira Paulista-SP na presença de ferro em sistema contínuo / Catalytic ozonation of the leachate from the Landfill Cachoeira Paulista- SP in the presence of iron in a continuous system

Renata Alves de Brito 13 October 2014 (has links)
O chorume é um líquido produzido na decomposição dos resíduos sólidos e apresenta riscos ambientais, devido à variedade de substancias poluentes presentes na matriz. O chorume in natura utilizado neste trabalho foi proveniente do aterro sanitário de Cachoeira Paulista - SP, sendo caracterizado com elevadas concentrações de COT (1233,33 mgL-1), DQO (3565,0 mgL-1) e DBO5/DQO = 0,099. Diante da baixa biodegradabilidade do chorume (DBO5/DQO < 0,2), utilizou-se a ozonização catalítica, em presença de ferro, em sistema contínuo, como uma alternativa para viabilizar o tratamento deste efluente. Diversas configurações de reatores foram avaliadas, sendo utilizados, inicialmente, reatores contínuos rudimentares (PVC). As avaliações reacionais e operacionais dos protótipos possibilitaram a elaboração de um reator construído com bases conceituais de engenharia, confeccionado em vidro borosilicato, e em dois módulos: o corpo do reator com duas entradas, sendo uma de alimentação, localizada acima, e a outra de introdução de ozônio, que foi feita por meio de um difusor de vidro sinterizado na base do reator. O segundo módulo foi feito para garantir que a espuma formada durante a reação fosse eliminada pela quebra da tensão através de ar comprimido, retornando-a, sob a forma líquida, ao sistema. As avaliações iniciais da ozonização catalítica do chorume in natura, para a verificação da potencialidade deste tratamento, foram realizadas sem o uso de um planejamento experimental, sendo o melhor resultado obtido na ordem de 72,64 % para a redução de COT. Após a seleção do reator de ozonização para o processo contínuo e a escolha do íon ferroso como catalisador, foi elaborado um planejamento fatorial fracionado (24-1) para avaliação das variáveis (potência, vazão de saída do reator, concentração de Fe2+, pH), no qual, o melhor resultado para a redução de COT foi de 59,38%. Este desempenho inferior para a redução de COT pode ser atribuído à substituição do gás de oxigênio puro por ar comprimido, reduzindo a vazão mássica de ozônio disponível para o tratamento. Entretanto, este processo pode ser viabilizado no tratamento prévio do chorume, pois a ozonização proporcionou uma elevada redução de DQO na ordem de 82,3 % e um aumento de 74,4% na biodegradabilidade (DBO5/DQO = 0,389) do chorume, podendo torná-lo potencialmente tratável por processos convencionais. / Leachate is a liquid produced in the decomposition of solid waste and presents environmental risks due to the variety of polluting substances existing in the matrix. The in natura leachate used in this work was from the landfill of the city Cachoeira Paulista in the state of São Paulo, which was characterized with high concentrations of TOC (1233.33 mgL-1) COD (3565.0 mg.L-1) and BOD5/COD = 0.099. Due to the low biodegradability of leachate (BOD5/COD < 0.2), the catalytic ozonation in the presence of iron in a continuous system was used as a viable alternative for the treatment of this effluent. Several configurations of reactors were evaluated, and, initially, rudimentary continuous reactors (PVC) were used. The reactional and operational evaluations of the prototypes enabled the creation of a reactor built on conceptual foundations of engineering, that was made of borosilicate glass, and in two modules: the body of the reactor with two entries, one for feeding, located above, and the other one for ozone introduction, made through a sintered glass diffuser at the bottom of the reactor. The second module was made to ensure that the foam formed during the reaction is eliminated by breaking the tension via compressed air, returning it, in liquid form, to the system. Initial assessments of the catalytic ozonation of the in natura leachate, to verify the potential of this treatment, were performed without the use of an experimental design, and the best result obtained was to reduce TOC on about 72.64 %. After selecting the ozonation reactor for continuous process and choosing ferrous ion as catalyst, a fractional factorial design (24-1) was prepared to evaluation the selected variables (potency, output flow of reactor, Fe2+ concentration, pH) in which the best result for the TOC reduction was 59.38%. This inferior performance for the TOC reduction can be associated to the replacement of pure oxygen gas by compressed air, reducing the ozone mass flow available to the treatment. However, this process can be made possible in the pretreatment of leachate, because the ozonation provided a high reduction of COD on about 82.3% and an increase of 74.4% on the biodegradability (BOD5/COD = 0.389) of leachate, and that can make it potentially treatable by conventional methods.
14

Corantes como importante classe de contaminantes ambientes - um estudo de caso / Dyes as an important class of environmental contaminants - a case of study

Danielle Palma de Oliveira 01 March 2005 (has links)
As amostras ambientais coletadas na área do Ribeirão dos Cristais, região metropolitana de São Paulo, apresentaram atividade mutagênica sistemática durante os últimos anos. De acordo com estudos já publicados em literatura, essa contaminação estava relacionada ao lançamento de efluentes líquidos de uma indústria de tingimento neste corpo d água. Essa indústria tinge principalmente nylon e poliéster, utilizando em seus processos azo corantes dispersos, entre outros. Os corantes de um produto comercial preto (BDCP), muito empregado por essa indústria, foram detectados recentemente em amostras ambientais coletadas nesse local e se mostraram pelo menos parcialmente, responsáveis pela mutagenicidade mencionada. Esses corantes foram identificados como c.I. Disperse Blue 373, C.I. Disperse Violet 93 e C.I. Disperse Orange 37. A água tratada proveniente do Ribeirão dos Cristais também mostrou atividade mutagênica e esta foi relacionada tanto à presença de nitrocompostos aromáticos, incluindo policíclicos, quanto de produtos mutagênicos secundários formados durante a desinfecção. Este trabalho teve como objetivos a caracterizaçãoquímica de amostras de efluente bruto e tratado, provenientes da indústria de tingimento, lançados no Ribeirão dos Cristais; a avaliação da presença dos corantes c.I. Disperse Blue 373, C.I. Disperse Violet 93 e c.I. Disperse Orange 37 em amostras de sedimento antes e após o lançamento; e a verificação da possível formação de compostos mutagênicos incolores, provenientes dos corantes, a partir do processo de cloração, os quais poderiam explicar a mutagenicidade da água tratada. As amostras de efluente bruto e tratado foram analisadas por Cromatografia em Camada Delgada (CCD) e os corantes do produto comercial preto (BDCP) foram detectados, dentre outros. Quando analisadas por Cromatografia em Fase Gasosa! Espectrometria de Massas (CG/EM) foram detectadas, preliminarmente, várias aminas aromáticas mutagênicas, dentre elas alguns produtos de clivagem dos corantes identificados. Os resultados indicaram que o tratamento empregado pela indústria (sistema de lodos ativados) não é eficiente na remoção desses compostos. Nas amostras de sedimento do Ribeirão dos Cristais, coletadas após o lançamento da indústria de tingimento, foram detectados por CCD o corante C.I. Disperse Blue 373 e o c.I. Disperse Orange 37, porém o corante violeta (C.I. Dispersse Violet 93) não foi detectado. A mutagenicidade das mesmas amostras foi avaliada com a linhagem YGI041 de Salmonella, com e sem S9 e a atividade mutagênica detectada pôde ser explicada pela presença dos corantes nas amostras avaliadas. Tendo em vista que nas amostras de água tratada não foram detectados corantes, porém foi observada atividade mutagênica relacionada à presença de nitrocompostos, submeteu-se uma solução do produto comercial BDCP, em concentração compatível com aquela detectada na água bruta, à cloração em condições similares àquelas realizadas pela Estação de Tratamento de Água (ETA). Após a cloração, foi verificada a formação de substâncias incolores, com atividade mutagênica e perfil cromatográfico semelhante ao apresentado por amostras de água tratada coletadas na saída da ETA. Desta forma, especula-se que as substâncias geradas possam estar relacionadas com a mutagenicidade detectada na água tratada. Os resultados obtidos neste trabalho demonstram que corantes azóicos e seus produtos relacionados são uma importante classe de contaminantes ambientais que deveriam ser melhor avaliados toxicologicamente, especialmente quanto a sua atividade genotóxica e carcinogênica tendo em vista o risco direto e indireto de exposição humana à esses compostos quando liberados para o meio ambiente. / Enviromnental samples collected at Cristais river area in the metropolitan region of São Paulo, had showed repeated mutagenic activity during the last years. According to published studies, this contamination was related to the discharge of a dye processing plant. This industry dyes mainly nylon and polyester, using azo disperse dyes, among others. Recently, the dye components of a black dye commercial product (BDCP), widely used by this industry, were detected in enviromnental samples collected in this area and were considered responsible, at least in part, for the cited mutagenicity. These dyes were identified as: C.I. Disperse Blue 373, C.I. Disperse Violet 93 and C.I. Disperse Orange 37. The drinking water from the Cristais river also showed mutagenic activity related to the presence of nitro aromatic compounds, including polycyclic ones, as well as the usual disinfection by products. The objectives of this work were: the chemical characterization of raw and treated effluent samples from the dye processing plant that discharges its effluent in Cristais river; the evaluation of the presence of C.I. Disperse Blue 373, c.I. Disperse Violet 93 and c.I. Disperse Orange 37 in sediment samples before and after the discharge; and the evaluation of the possible generation of non-colored mutagenic compounds, derived from the dyes, during the disinfection step that could explain the mutagenicity of the drinking water. The raw and treated effluent samples were analyzed using Thin Layer Chromatography (TLC) and the dye components of the BDCP were detected, among others. Several mutagenic aromatic amines, including cleavage by-products of the detected dyes, were preliminary detected using gas chromatography/ mass spectrometry (GC/MS). The results demonstrated that the treatment applied by the industry (activated sludge) was not efficient in the removal of theses compounds. In the Cristais river sediment samples collected downstream the dye processing plant discharge, we detected the dyes C.I. Disperse Blue 373 and C.I. Disperse Orange 37 using TLC, however, the violet component (C.I. Disperse Violet 93) was not detected. The mutagenicity of these samples were evaluated using the strain YG1041 of Salmonella, in the presence and absence of S9 and the mutagenic activity observed could be explained by the presence of the dyes in the samples. Taking into account that dyes were not detected in drinking water samples, but the samples showed mutagenicity related to the presence of nitrocompounds, a solution of the commercial product (BDCP), at similar concentration found in raw water, was chlorinated using the Drinking Water Treatment Plant (DWTP) conditions. After the chlorination, the formation of non-colored substances was verified, and these compounds showed mutagenic and chromatographic profiles similar to the drinking water collected at DWTP. In this sense, we suggest that the generated substances could be related to the mutagenic activity previously detected in the drinking water. The results obtained in this study demonstrated that azo dyes and related compounds are an important class of environmental contaminants that should be better evaluated in relation of its toxicity, mainly in relation to their genotoxic and carcinogenic effects, considering the direct and indirect human exposure risk associated to these compounds once in the environrnent.
15

Ozonização catalítica do chorume proveniente do aterro sanitário de Cachoeira Paulista-SP na presença de ferro em sistema contínuo / Catalytic ozonation of the leachate from the Landfill Cachoeira Paulista- SP in the presence of iron in a continuous system

Brito, Renata Alves de 13 October 2014 (has links)
O chorume é um líquido produzido na decomposição dos resíduos sólidos e apresenta riscos ambientais, devido à variedade de substancias poluentes presentes na matriz. O chorume in natura utilizado neste trabalho foi proveniente do aterro sanitário de Cachoeira Paulista - SP, sendo caracterizado com elevadas concentrações de COT (1233,33 mgL-1), DQO (3565,0 mgL-1) e DBO5/DQO = 0,099. Diante da baixa biodegradabilidade do chorume (DBO5/DQO < 0,2), utilizou-se a ozonização catalítica, em presença de ferro, em sistema contínuo, como uma alternativa para viabilizar o tratamento deste efluente. Diversas configurações de reatores foram avaliadas, sendo utilizados, inicialmente, reatores contínuos rudimentares (PVC). As avaliações reacionais e operacionais dos protótipos possibilitaram a elaboração de um reator construído com bases conceituais de engenharia, confeccionado em vidro borosilicato, e em dois módulos: o corpo do reator com duas entradas, sendo uma de alimentação, localizada acima, e a outra de introdução de ozônio, que foi feita por meio de um difusor de vidro sinterizado na base do reator. O segundo módulo foi feito para garantir que a espuma formada durante a reação fosse eliminada pela quebra da tensão através de ar comprimido, retornando-a, sob a forma líquida, ao sistema. As avaliações iniciais da ozonização catalítica do chorume in natura, para a verificação da potencialidade deste tratamento, foram realizadas sem o uso de um planejamento experimental, sendo o melhor resultado obtido na ordem de 72,64 % para a redução de COT. Após a seleção do reator de ozonização para o processo contínuo e a escolha do íon ferroso como catalisador, foi elaborado um planejamento fatorial fracionado (24-1) para avaliação das variáveis (potência, vazão de saída do reator, concentração de Fe2+, pH), no qual, o melhor resultado para a redução de COT foi de 59,38%. Este desempenho inferior para a redução de COT pode ser atribuído à substituição do gás de oxigênio puro por ar comprimido, reduzindo a vazão mássica de ozônio disponível para o tratamento. Entretanto, este processo pode ser viabilizado no tratamento prévio do chorume, pois a ozonização proporcionou uma elevada redução de DQO na ordem de 82,3 % e um aumento de 74,4% na biodegradabilidade (DBO5/DQO = 0,389) do chorume, podendo torná-lo potencialmente tratável por processos convencionais. / Leachate is a liquid produced in the decomposition of solid waste and presents environmental risks due to the variety of polluting substances existing in the matrix. The in natura leachate used in this work was from the landfill of the city Cachoeira Paulista in the state of São Paulo, which was characterized with high concentrations of TOC (1233.33 mgL-1) COD (3565.0 mg.L-1) and BOD5/COD = 0.099. Due to the low biodegradability of leachate (BOD5/COD < 0.2), the catalytic ozonation in the presence of iron in a continuous system was used as a viable alternative for the treatment of this effluent. Several configurations of reactors were evaluated, and, initially, rudimentary continuous reactors (PVC) were used. The reactional and operational evaluations of the prototypes enabled the creation of a reactor built on conceptual foundations of engineering, that was made of borosilicate glass, and in two modules: the body of the reactor with two entries, one for feeding, located above, and the other one for ozone introduction, made through a sintered glass diffuser at the bottom of the reactor. The second module was made to ensure that the foam formed during the reaction is eliminated by breaking the tension via compressed air, returning it, in liquid form, to the system. Initial assessments of the catalytic ozonation of the in natura leachate, to verify the potential of this treatment, were performed without the use of an experimental design, and the best result obtained was to reduce TOC on about 72.64 %. After selecting the ozonation reactor for continuous process and choosing ferrous ion as catalyst, a fractional factorial design (24-1) was prepared to evaluation the selected variables (potency, output flow of reactor, Fe2+ concentration, pH) in which the best result for the TOC reduction was 59.38%. This inferior performance for the TOC reduction can be associated to the replacement of pure oxygen gas by compressed air, reducing the ozone mass flow available to the treatment. However, this process can be made possible in the pretreatment of leachate, because the ozonation provided a high reduction of COD on about 82.3% and an increase of 74.4% on the biodegradability (BOD5/COD = 0.389) of leachate, and that can make it potentially treatable by conventional methods.
16

Influência da recuperação e retorno de lodo efluente sobre a capacidade e eficiência de tratamento de reatores UASB

Silva, Suênia da 22 June 2017 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2018-10-31T13:53:06Z No. of bitstreams: 1 PDF - Suênia da Silva.pdf: 30135276 bytes, checksum: 5f7406e50f4c80ad94998275570d45c4 (MD5) / Made available in DSpace on 2018-10-31T13:53:06Z (GMT). No. of bitstreams: 1 PDF - Suênia da Silva.pdf: 30135276 bytes, checksum: 5f7406e50f4c80ad94998275570d45c4 (MD5) Previous issue date: 2017-06-22 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Resumo disponível do PDF da dissertação. / Resumo disponível do PDF da dissertação.
17

Pós-tratamento de efluentes de filtro anaeróbio precedido de tanque séptico por filtros aeróbios intermitentes de areia

Santos, Leonardo Rodrigues dos 06 November 2012 (has links)
Made available in DSpace on 2015-09-25T12:20:08Z (GMT). No. of bitstreams: 1 Leonardo Rodrigues dos Santos.pdf: 1589161 bytes, checksum: 70a093bacbb900a6535a34862626d355 (MD5) Previous issue date: 2012-11-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The discharging effluents in natura in soil or fresh water resources, directly or indirectly, this results beyond several problems socio environmental, in significant impacts about terrestrial and aquatic life. The absence of treatment in the efluents and your incorrect destination contribute to worsen the environment and the public health. This study aimed to evaluate the application the intermittent aerobic sand filters, as alternative system of post-treatment of effluents preceded of the septic tank and anaerobic filter, aiming the removal of nutrients, organic matter sewage from the science and technology center (STC). The university of Paraiba (UEPB) the system of pos-treatment built in the study is formed intermittent aerobic sand filters composed by three boxes of polyethylene fiber (one that acts like equalization tank and the other two act like aerobic filters.) the two aerobic sand filters (FA1 and FA2) were filed and with gravel and sand in the following proportion: 15 cm of gravel nº 3 in the base, 15 cm of gravel in the superior portion: 15 cm of gravel nº3 in the base, 30 cm of sand in the middle portion immediately above the gravel layer of the base 15 cm of gravel in the superior portion, immediately above the sand layer. The sand was the same, for both FA1 and FA2. The sand filters were fed by down stream. FA1 received effluents of equalization tank during 2 minutes and 45 seconds marked by stop watch, that and corresponds of a flow of 100 L of effluents. FA2 received effluents of the equalization tank during 5 minutes and 30 seconds, corresponding to 200 L of effluents. The average flow a minute was 22.84 l/m. it was verified low removal of organic natter through of total and filtered DQO, in the intermitted aerobic sand filters, with removal efficient bellow the minimum probable by NBR 13969/97 that is 40% may be associated to a short period of time of hydraulic detention in the septic tank due to the lack of periodic cleaning in the septic tank, passing to work like a single passage box. There were great efficiencies in the removal of nutrients, showing a good capacity of nitrification revealed in the nitrate concentration (28 mg/l and 29 mg/l) in FA1 and FA2 respectively and the different rates of application in the two intermitted aerobic sand filters influenced in the process of nitrification. / O lançamento de efluentes in natura nos solos ou nos recursos hídricos, seja de forma direta ou indireta, resulta, além de vários problemas socioambientais, em impactos significativos sobre a vida terrestre e aquática. A ausência de tratamento dos esgotos e sua destinação incorreta contribuem para agravar os problemas ambientais e particularmente de saúde pública. Este estudo tem como objetivo geral avaliar a aplicação de filtros aeróbios intermitentes de areia, como sistema alternativo de pós-tratamento de efluentes de filtro anaeróbio precedido de tanque séptico, visando à remoção de nutrientes e matéria orgânica de esgotos provenientes do Centro de Ciências e Tecnologia (CCT) da Universidade Estadual da Paraíba (UEPB). O sistema de pós-tratamento construído nesse estudo é formado por filtros aeróbios intermitentes de areia composto de caixas de fibra em polietileno (uma que atua como tanque de equalização e as outras duas como filtros aeróbios). Os dois filtros aeróbios de areia (FA 1 e FA 2) foram preenchidos com brita e areia na seguinte proporção: 15 cm de brita n&#8304; 3 na base; 30 cm de areia na porção mediana, logo acima da camada de britas da base; 15 cm de brita na porção superior, logo acima da camada de areia. A areia utilizada foi a mesma, tanto para o FA 1 como para o FA 2.Os filtros de areia foram alimentados por meio de fluxo descendente. O FA1 recebeu efluente do tanque de equalização por 2 minutos e 45 segundos, marcado por cronômetro, o que corresponde a uma vazão de 100 L/dia de efluente. Já o FA2 recebeu efluente do tanque de equalização por 5 minutos e 30 segundos, correspondendo a 200 L/dia de efluente. A vazão média do sistema anaeróbio por minuto foi de 22.84 L/min. Verificou-se baixa remoção de matéria orgânica medida através da DQO total e filtrada, nos filtros aeróbios intermitentes de areia, com eficiências de remoção abaixo do mínimo previsto pela NBR 13969/97 que é de 40%, podendo estar associada ao curto tempo de detenção hidráulica no tanque séptico decorrente da falta de limpeza periódica no tanque séptico, passando a funcionar como uma simples caixa de passagem. Houve ótimas eficiências na remoção de sólidos suspensos no efluente dos filtros aeróbios. Os filtros de areia foram eficientes na transformação dos nutrientes, mostrando boa capacidade de nitrificação, revelada nas concentrações de nitratos (28,31 mg/L e 19,41 mg/L) em FA1 e FA2 respectivamente e as diferentes taxas de aplicação nos dois filtros aeróbios intermitentes de areia influenciaram no processo de nitrificação.
18

Biofiltro aerado submerso aplicado ao pós-tratamento de efluente de reator UASB, sob condições hidráulicas desfavoráveis: estudo em escala real / Submerged aerated biofilter used for post-treatment of the effluent of an UASB reactor, under unfavorable hydraulic conditions: full-scale study

Godoy, Thais Gorga de 14 September 2007 (has links)
Esta pesquisa avaliou a eficiência do biofiltro aerado submerso empregado no pós-tratamento do efluente do reator anaeróbio de manta de lodo (UASB), em escala real, localizado na ETE Água Vermelha em São Carlos, SP, sob condições hidráulicas desfavoráveis. Estudou-se a remoção de matéria orgânica e de sólidos, a possibilidade de remoção de nitrogênio e fósforo e também as características da biomassa aderida ao meio suporte. O estudo foi desenvolvido em duas fases, uma sem a adição de inóculo (fase I) e outra com inoculação (fase II). Na fase I foi aplicada vazão de 380 m³/dia, cargas orgânicas volumétricas (COV) de 3kgDQO/m³.dia com carga hidráulica (CH) de 8 m³/m².dia e tempo de detenção hidráulica (TDH) de 170 minutos. Nesta fase o biofiltro alcançou eficiências médias de 40% na remoção de matéria orgânica (DQO) e de 35% para os SST. Na segunda fase foram aplicadas vazões de 500 m³/dia, COV de 4 kg DQO/ m³.dia com CH de 11 m³/ m².dia e TDH de 130 minutos. O BAS apresentou eficiências médias de remoção de DQO, \'COT IND.F\' e SST de 36%, 60% e 30%, respectivamente, para a fase II. A conversão de nitrito a nitrato foi considerada desprezível, podendo ser atribuída ao alto valor de DQO afluente ao BAS, à ocorrência de nitrificação e desnitrificação no mesmo biofilme e à distribuição ineficiente de ar no interior do reator. O biofiltro não apresentou bons resultados quanto à remoção de fósforo durante a pesquisa. O estudo permitiu concluir que o BAS apresentou um desempenho satisfatório como unidade de pós-tratamento de reator UASB na fase de partida, mesmo sendo submetido a altas cargas hidráulicas e orgânicas. Constatou-se, portanto, que o emprego do biofiltro aerado submerso apresenta-se como uma alternativa vantajosa para o pós-tratamento do efluente de reatores anaeróbios, produzindo um efluente de excelente qualidade. / This research evaluated the efficiency of a full scale submerged aerated biofilter (SAB) used for post-treatment of the effluent of an upflow anaerobic sludge blanket (UASB) reactor, located in the wastewater treatment plant Água Vermelha (São Carlos, SP, Brazil), under unfavorable hydraulic conditions. The removal of organic matter and solids, the possibility of removal of nitrogen and phosphorus and also the characterization of biomass attached to the packing media were studied. This study vas developed in two phases, one without reactor seeding (phase I), and another when the reactor was seeded (phase II). At phase I, a flow rate of 380 m³/d and a volumetric loading rate of 3 kgCOD/m³.d with hydraulic load (HL) of 8 m³/m².d were applied, with 170 minutes of hydraulic retention time (HRT). In this phase the biofilter reached average efficiencies of 40% in organic matter removal (COD) and 35% for TSS. Already in phase II, a flow rate of 500 m³/d, a volumetric loading rate of 4kgCOD/m³.d with HL of 11 m³/ m².dia were applied, with 130 minutes of HRT. The SAB allowed average removal efficiencies of COD, \'TOC IND.F\' and TSS of 36%, 60% and 30%, respectively, for phase II. The conversion of nitrite to nitrate was considered worthless, likely attributed to the high value of affluent COD to the SAB, the occurrence of nitrification and denitrification in the same biofilm and the inefficient air distribution in the interior of the reactor. The biofilter did not present good results in phosphorus removal. This study allowed to conclude that the aerated submerged biological filter presented a satisfactory performance as a post-treatment unit of an UASB reactor during the start-up phase, being submitted to high hydraulic and organic loads. It was found that the employment of the submerged aerated biofilter is an advantageous alternative as anaerobic effluent post-treatment, producing excellent quality effluent.
19

Parâmetros de tratabilidade em sistemas de alagados construídos aplicado ao reuso de resíduos de dessalinização

Zaika, Marin Gadens Berton 10 April 2018 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-06-18T17:08:54Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Zaika, Marina Gadens.pdf: 3417069 bytes, checksum: e7a555d3e211bdb7368517e8e8789617 (MD5) / Made available in DSpace on 2018-06-18T17:08:54Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Zaika, Marina Gadens.pdf: 3417069 bytes, checksum: e7a555d3e211bdb7368517e8e8789617 (MD5) Previous issue date: 2018-04-10 / A pesquisa teve como objetivo a avaliação dos parâmetros de tratabilidade, designados assim, como as variáveis, fatores, configurações hidráulicas e de operação, que por hipótese, potencialmente oferecessem influência no processo de melhoria da qualidade da água residuária (concentrado salino) decorrente da dessalinização por ultrafiltração e osmose reversa, através da aplicação de Sistemas Alagados Construídos, cultivados com capim-elefante (Pennisetum purpureum, Schum.). Os estudos foram conduzidos em escala de bancada, dentro de uma estufa agrícola semi-climatizada. Foram confeccionadas doze unidades experimentais, e estabelecidos quatro configurações de tratamento com três repetições cada, operadas e monitoradas durante cinco meses, variando em função da operação do sistema, se de fluxo contínuo ou de regime estático, e também no tempo de detenção hidráulica de três ou quatro dias. Amostras de água foram coletadas na entrada e na saída de cada unidade, e foram analisados em laboratório para a caracterização físico-química e monitoramento dos parâmetros: pH, alcalinidade, oxigênio dissolvido, turbidez, salinidade, dureza, cálcio, cloretos, sulfatos, condutividade elétrica, sólidos dissolvidos totais e demanda química de oxigênio. Os resultados foram submetidos à análise de variância e teste de Tukey, em nível de 95% de confiança, utilizando-se o programa estatístico SISVAR. Os sistemas que foram submetidos ao regime estático, com tempo de detenção hidráulica de quatro dias, nas três primeiras semanas de operação, mostraram ser mais eficientes na remoção média de salinidade (53,1%), dureza (69,2%), cálcio (66,7%), cloreto (44,5%), condutividade elétrica (40,7%) e sólidos dissolvidos totais (86,7%). A planta conseguiu absorver 0,25% do íon sódio pelas suas raízes para a sua nutrição, segundo resultados de ensaio de microscopia eletrônica. / The aim of this research was to evaluate the treatability parameters, which were defined as variables, factors, hydraulic and operating configurations, which, by hypothesis, could potentially influence the process of improving the quality of wastewater (brine) resulting from desalination by ultrafiltration and reverse osmosis, through the application of Constructed Flooded Systems, cultivated with elephantgrass (Pennisetum purpureum, Schum.). The studies were conducted on bench scale, within a semi-heated agricultural greenhouse. Twelve experimental units were established, and four treatment configurations were established with three replicates each, operated and monitored for five months, varying according to the operation of the system, whether continuous or static, and also in the hydraulic holding time of three or four days. Samples of water were collected at the entrance and exit of each unit, and were analyzed in the laboratory for the physico-chemical characterization and monitoring of parameters: pH, alkalinity, dissolved oxygen, turbidity, salinity, hardness, calcium, chlorides, sulfates, conductivity total dissolved solids and chemical oxygen demand. The results were submitted to analysis of variance and Tukey's test, at a 95% confidence level, using the statistical program SISVAR. The systems that were submitted to the static regime, with hydraulic detention time of four days, during the first three weeks of operation, showed to be more efficient in the average removal of salinity (53.1%), hardness (69.2%), calcium (66.7%), chloride (44.5%), electrical conductivity (40.7%) and total dissolved solids (86.7%). The plant was able to absorb 0.25% of the sodium ion by its roots for its nutrition, according to results of the electron microscopy.
20

Avaliação do desempenho de bomba multifásica na geração de microbolhas de ar para o processo de flotação por ar dissolvido aplicado ao pré-tratamento de efluente de indústria têxtil / Evaluation of performance of multiphase pump in the air microbubble generation for dissolved air flotation process applied to pre-treatment of textile wastewater

Pioltine, André 25 March 2009 (has links)
A flotação por ar dissolvido (FAD) é um método de separação de fases bastante utilizado em sistemas de tratamento de efluentes industriais. Nos últimos 20 anos, numerosos avanços têm contribuído para uma maior eficiência deste processo. Entre estes, podem-se citar os avanços nos métodos para a saturação de ar na água. Atualmente tem-se realizado estudos com a utilização de bombas multifásicas em substituição às unidades de saturação tradicionais, com vistas a se buscar maior simplicidade e facilidade operacional, aliados à menor necessidade de manutenção periódica da unidade de saturação. Desta forma, o presente trabalho teve como objetivo avaliar o desempenho de uma bomba multifásica na geração de microbolhas de ar no processo de flotação por ar dissolvido para o tratamento de efluente de indústria têxtil. O projeto foi dividido nas seguintes etapas: Etapa I - com o emprego do Flotateste, foram determinadas as dosagens adequadas de coagulante e polímero para o tratamento do despejo líquido industrial em estudo; Etapa II - utilizando-se uma unidade piloto de flotação por ar dissolvido montada nas instalações de uma indústria têxtil, avaliou-se a influência das condições de operação (taxa de aplicação superficial, razão de recirculação, pressão de saturação e quantidade de ar fornecida) na eficiência do sistema constituído pela bomba multifásica. Considerando a taxa de aplicação superficial empregada neste estudo, a qual foi mantida em faixa estreita de valor (TASclar em torno de 128,6 ± 10 m/d), verificou-se que os maiores valores de eficiência de remoção dos parâmetros monitorados foram obtidos nos ensaios realizados com razão de recirculação igual a 30% associados ao fornecimento de ar de 13%. Nos ensaios onde se realizou a avaliação da concentração de ar presente na recirculação pressurizada, as concentrações de ar efetivamente fornecidas (fração dissolvida e não dissolvida) pelo sistema constituído pela bomba multifásica, foram superiores às concentrações máximas teóricas de ar dissolvido calculadas a partir da Lei de Henry. O valor da relação A/S que forneceu os melhores resultados situou-se em torno de 0,015 g ar/g sólidos. Desta forma, sugere-se tal valor como subsídio ao projeto de sistema de flotação constituído pela tecnologia em estudo nesta pesquisa. / The dissolved air flotation is a method for solid/liquid separation that is used in the industries to treat the wastewater. In the last 20 years, several advances have been added to increase the process\' efficiency. For example, there are the advances in the air saturation methods. Nowadays, studies have been carried out with the use of multiphase pumps instead of conventional saturator units. This way, the aim of this research was to evaluate the performance of a multiphase pump in the air microbubble generation for dissolved air flotation process that is applied to treat the effluent of textile industry. The research was performed in two stages: i) on laboratory scale (Flotatest), where the adequate dosages of coagulant and flocculation aid were carried out; ii) in a pilot unit, where studies were conducted aiming at the evaluation of operational conditions in the system\'s efficiency. In the pilot unit (hydraulic surface loading equal to 128,6 ± 10m/d) , it was verified that the best results in terms of removal efficiency of monitored parameters were obtained for the essays performed with recirculation ratio equal to 30%, air supply of 13% and A/S ratio equal to 0.015 g air/g solids. The air concentrations supplied (dissolved fraction and non-dissolved fraction) by the system were higher than the maximum theoretical concentration of dissolved air (Henry\'s law).

Page generated in 0.0777 seconds