• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 77
  • Tagged with
  • 77
  • 77
  • 54
  • 37
  • 27
  • 26
  • 16
  • 15
  • 13
  • 12
  • 12
  • 12
  • 11
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caracterização do esgoto tratado na ETE Mangueira e a viabilidade de seu uso em mudas de eucalipto

José Silva, Robson 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T17:39:16Z (GMT). No. of bitstreams: 2 arquivo2633_1.pdf: 9062621 bytes, checksum: 8d9817467305daa4c441283075a73531 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Fundação de Amparo à Ciência e Tecnologia do Estado de Pernambuco / Este trabalho avaliou a viabilidade do uso de efluente de esgoto doméstico tratado na irrigação de mudas de eucalipto da espécie eucaliptus urograndis. O experimento foi realizado na Estação de Tratamento de Esgotos da Mangueira, cujo sistema de tratamento é definido pela combinação de reatores anaeróbios (UASB) e lagoa de polimento. Dessa forma, cada muda foi plantada em vaso contendo 10 kg de solo e as lâminas de irrigação foram definidas com base no Índice CP, ou Capacidade de Pote para o solo, estabelecendo 6 tratamentos com 4 repetições cada. Dos 6 tratamentos, T1, T2, T3 e T4 consistiram na irrigação com efluente, respectivamente a 100%, 80%, 60% e 40% do Índice CP; enquanto T5 e T6 consistiram na irrigação com água a 80% do Índice CP, tendo adição de NPK apenas em T5. O sistema de tratamento da ETE mostrou uma eficiência de 84% e 70% na remoção de DBO e DQO, respectivamente. Em relação à planta, o tratamento estatístico mostrou que as mudas irrigadas com efluente (tratamento T2 e T3) apresentaram melhor desempenho quanto aos parâmetros de altura, número de folhas e matéria seca. Além disso, a fertirrigação com efluente (tratamento T2) foi capaz de acumular nutrientes como N nas folhas e caule das plantas. Esses resultados comprovaram que o uso de efluente para irrigação de mudas de eucalipto é viável quanto aos aspectos sanitários e agronômicos
2

Desreguladores endócrinos presentes em matrizes ambientais: análise por SPE-HPLC e remoção com argila pilarizada. / EDs present in environmental matrices: analysis by SPE-HPLC and removal with pillared clay.

Vidal, Carla Bastos 09 September 2015 (has links)
VIDAL, C. B. Desreguladores endócrinos presentes em matrizes ambientais: análise por SPE-HPLC e remoção com argila pilarizada. 2015. 159 f. Tese (Doutorado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2015. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2015-12-14T16:11:01Z No. of bitstreams: 1 2015_tese_cbvidal.pdf: 5654711 bytes, checksum: b584e553a1fbdf21c0ceef2afd77b3e5 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2015-12-18T19:04:41Z (GMT) No. of bitstreams: 1 2015_tese_cbvidal.pdf: 5654711 bytes, checksum: b584e553a1fbdf21c0ceef2afd77b3e5 (MD5) / Made available in DSpace on 2015-12-18T19:04:41Z (GMT). No. of bitstreams: 1 2015_tese_cbvidal.pdf: 5654711 bytes, checksum: b584e553a1fbdf21c0ceef2afd77b3e5 (MD5) Previous issue date: 2015-09-09 / The substances called endocrine disruptors (ED) are a new category of environmental pollutants that interfere in the functions of the endocrine system, being found in the environment at concentrations in the order ug L-1 and L-1 ng. The WWTP effluent release are important sources of such compounds in the aquatic environment since the conventional methods of water treatment and sewage not completely remove these micropollutants. In this study we assessed the efficiency of pillared clay using tin dioxide as an agent for removing pilarizante DE (of different classes) in environmental matrices. Experimental design was used to evaluate the factors affecting the adsorptive process. For optimization step of the previously validated analytical method it was studied the effectiveness of three commercial SPE cartridges. Tributaries concentrations were obtained, effluents and removal efficiencies of two sewage treatment plants operating in full scale (UASB + chlorination). Finally, DE adsorption experiments were performed in single and multicomponent systems as well as regenerating the adsorbent. The Oasis and Strata-X cartridge efficiency showed high and selective ability, however, only Strata-X cartridge was selected in this study, since it showed higher recovery values (%) 50 (Sulfamethoxazol); 83 (Trimethoprim); 171 (diclofenac); 183 (estrone); 14 (17β-estradiol) and 82 (Bisphenol A). The chromatographic method was selective for all compounds studied, except for the hormone estriol. The quantification limit values (1.28 to 29.97 ng L-1) and detection limit (from 0.42 to 9.89 ng L-1) obtained in this study were low. Most of the recovery values was less than 100%. It was observed that the esgosto tributary of the studied WWTPs still present in their waste considerable amounts of DE, with average values of effluents from 21.94 to 311.79 ng L-1 for ETE Aracapé and 4.41 to 123.47 ng L 1 to ETE Mondubim, which highlights the need for a step of post-treatment in the studied WWTPs. They have found greater efficiencies treatment for compounds bisphenol A (90.8%) and 17α-ethinylestradiol (76.6%) ETE Mondubim. As for the compounds sulfamethoxazole and estrone it was observed an increase in effluent values of 18.9 and 28.6% respectively for the ETE Aracapé. The pillared clay showed higher adsorption capacity compared to the natural clay, due to enlargement of the interlayer space of the clay and increased volume of mesopores as evidenced by the characterization techniques. After analyzing the results of the factorial design was set optimum values of the variables found in the process to make the studies of kinetics and adsorption isotherm, which was temperature - 25 ° C; Agitation - 300 rpm; Mass of adsorbent: 300 mg and pH - 3. The kinetic study indicated 1 hour equilibration time, with the model of pseudo-second order which best fit to the data. The intraparticle diffusion mechanism was not the determining step of the speed and mass transfer process. The majority of the DE compounds obtained greater removal in multicomponent system when compared to single-component studies. The experimental data better adsorption isotherm set the model Freundlich except to refer to the TMP and BPA compounds. The sorbent regeneration tests indicated a significant reduction in the adsorption capacity of pillared clay in the 2nd adsorption cycle for TMP and compounds BPA, with a reduction of 99.5 and 79.2%, respectively. For E2 and E1 compounds, adsorption was affected after the 3rd cycle. / As substâncias denominadas desreguladores endócrinos (DE) são uma categoria recente de poluentes ambientais que interferem nas funções do sistema endócrino, sendo encontradas no meio ambiente em concentrações na ordem de μg L-1 e ng L-1. Os efluentes de ETEs são importantes fontes de lançamento desses compostos no ambiente aquático uma vez que os processos convencionais de tratamento de água e esgoto não removem totalmente esses micropoluentes. Neste trabalho avaliou-se a eficiência da argila pilarizada utilizando o dióxido de estanho como agente pilarizante para remoção de DE (de diferentes classes) em matrizes ambientais. Foi utilizado o planejamento experimental para avaliação dos fatores que afetaram o processo adsortivo. Para etapa de otimização do método analítico anteriormente validado foi estudada a eficiência de três cartuchos SPE comerciais. Foram obtidas concentrações afluentes, efluentes e eficiências de remoção em duas estações de tratamento de esgotos que operavam em escala real (UASB + cloração). Por fim, foram realizados experimentos de adsorção de DE em sistemas mono e multicomponentes, assim como de regeneração do adsorvente. Os cartuchos Oasis e Strata-X mostraram elevada eficiência e capacidade seletiva, entretanto apenas o cartucho Strata-X foi o selecionado neste trabalho, uma vez que o mesmo mostrou maiores valores de recuperação (%) de 50 (Sulfamethoxazol); 83 (Trimetoprima); 171 (Diclofenaco); 183 (Estrona); 14 (17β-estradiol) e 82 (Bisfenol-A). O método cromatográfico mostrou-se seletivo para todos os compostos estudados, exceto para o hormônio estriol. Os valores de limite de quantificação (1,28-29,97 ng L-1) e limite de detecção (0,42-9,89 ng L-1) obtidos neste trabalho foram considerados baixos. A maioria dos valores de recuperação encontrados foi menor que 100%. Foi possível observar que o esgosto afluente às ETEs estudadas ainda apresentam em seus efluentes quantidades consideráveis de DE, com valores médios efluentes entre 21,94-311,79 ng L-1 para ETE Aracapé e 4,41-123,47 ng L-1 para ETE Mondubim, o que evidencia a necessidade de uma etapa de pós-tratamento nas ETEs estudadas. Foram encontradas maiores eficiências de tratamento para os compostos bisfenol A (90,8%) e 17α-etinilestradiol (76,6%) na ETE Mondubim. Já para os compostos sulfametoxazol e estrona foi observado um incremento nos valores efluentes de 18,9 e 28,6%, respectivamente para a ETE Aracapé. A argila pilarizada mostrou maior capacidade de adsorção quando comparada à argila natural, devido ao alargamento do espaço interlamelar da argila e aumento no volume de mesoporos como comprovado pelas técnicas de caracterização. Após análise dos resultados do planejamento fatorial foi fixado os valores ótimos encontrados das variáveis no processo para compor os estudos de cinética e isoterma de adsorção, os quais foram Temperatura – 25 °C; Agitação – 300 rpm; Massa do adsorvente: 300 mg e pH – 3. O estudo cinético indicou tempo de equilíbrio de 1 hora, sendo o modelo de pseudo-segunda ordem o que melhor se ajustou aos dados. O mecanismo de difusão intrapartícula não foi a etapa determinante da velocidade e no processo de transferência de massa. A maioria dos compostos DE estudados obteve maior remoção em sistema multicomponente quando comparados aos estudos monocomponentes. Os dados experimentais de isoterma de adsorção melhor se ajustaram ao modelo de Freundlich com exceção aos referentes aos compostos TMP e BPA. Os testes de regeneração do adsorvente indicaram significante redução da capacidade de adsorção da argila pilarizada no 2º ciclo de adsorção para os compostos TMP e BPA, com redução de 99,5 e 79,2 %, respectivamente. Para os compostos E2 e E1, a adsorção foi afetada após o 3º ciclo.
3

Influência do aporte de águas pluviais nos parâmetros da qualidade das águas residuárias da ETE Vista Verde.

Alexander Antonio Peres Gutiérrez Aguiñada 14 February 2008 (has links)
Para a coleta das águas residuárias e águas pluviais de uma comunidade e o transporte adequado para uma estação de tratamento de esgoto ou lançamento final, pode-se utilizar três tipos de sistema de esgotamento: sistema unitário, sistema separador parcial ou misto e sistema separador absoluto, sendo que no Brasil a legislação estabelece que seja adotado o sistema separador absoluto, concebido para coletar apenas as águas residuárias. Entretanto, na prática isto não ocorre, devido às ligações clandestinas de águas pluviais geradas pela falta de fiscalização e à ausência de redes de águas residuárias que atendam toda a população, gerando problemas na operação das Estações de Tratamento de Esgotos, por não suportarem o aumento da vazão afluente, ocorre a sobrecarga hidráulica e arraste de materiais sólidos das tubulações pluviais para Estações de Tratamento de Esgotos. O presente trabalho busca avaliar a qualidade dos esgotos combinados da Estação de Tratamento de Esgoto Vista Verde na cidade de São José dos Campos em períodos secos e chuvosos, a fim de analisar os impactos do aporte de águas pluviais, verificar se os mesmos se enquadram na RESOLUÇÃO DO CONAMA N 357 de 17 de Março de 2005 e fornecer propostas para mitigar os impactos gerados pelas tormentas na operação e no processo de tratamento de esgotos. Para isso contamos com a colaboração da SABESP que forneceu dados diários de vazão, oxigênio dissolvido, pH e sólidos sedimentáveis. Também foi realizado um trabalho de campo afim de conhecer o local e realizar coleta dos parâmetros (DBO, DQO, OD, pH, sólidos sedimentáveis e sólidos suspensos). Pode-se concluir que os efeitos da água pluvial nos parâmetros analisados influenciam na operação da ETE Vista Verde, mas não é a única responsável pela alteração na operação, pois a própria operação da ETE demonstra-se ineficiente mesmo em períodos de seca, tendo como outro responsável seu critério de operação; cabendo reavaliar os critérios de operação da mesma (aeradores). Os parâmetros DBO e OD não se enquadraram à legislação em vigor sendo que apenas o pH atendeu os padrões estabelecidos. Para solução do problema sugere-se uma reavaliação da operação dos aeradores, ou a implantação das técnicas alternativas lineares de drenagem urbana, que demonstram grandes eficiências de remoção da poluição contida no escoamento superficial.
4

Análise da aplicação do licenciamento ambiental às estações de tratamento de esgoto: uma contribuição a partir de estudos de caso na bacia hidrográfica do Rio São Francisco

Pereira, Filipe Lima January 2012 (has links)
Submitted by MAASA Secretaria (maasa@ufba.br) on 2013-03-22T15:35:21Z No. of bitstreams: 1 dissertacao_maasa_pereira_filipe_2012.pdf: 1570832 bytes, checksum: 20ea007107acde512855f99d0e6bcfb3 (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-03-23T14:18:37Z (GMT) No. of bitstreams: 1 dissertacao_maasa_pereira_filipe_2012.pdf: 1570832 bytes, checksum: 20ea007107acde512855f99d0e6bcfb3 (MD5) / Made available in DSpace on 2013-03-23T14:18:37Z (GMT). No. of bitstreams: 1 dissertacao_maasa_pereira_filipe_2012.pdf: 1570832 bytes, checksum: 20ea007107acde512855f99d0e6bcfb3 (MD5) Previous issue date: 2012 / A pesquisa qualitativa, ora apresentada, visa analisar a aplicação do licenciamento ambiental às estações de tratamento de esgoto no estado da Bahia através de um conjunto de estudos de caso dessa natureza localizados na bacia hidrográfica do rio São Francisco. Para tanto, foram formulados modelos analíticos que buscam indicar os elementos essenciais a serem observados nessa aplicação. A questão de pesquisa que deu origem ao trabalho surgiu da observação primária, feita pelo pesquisador, das percepções que os representantes dos proponentes e do órgão ambiental tinham acerca da aplicação desse instrumento. Essa observação inicial se configurou em um conjunto de pressupostos iniciais do trabalho, os quais foram submetidos a um processo científico de verificação, através das entrevistas semiestruturadas realizadas. O confronto entre a prática, captado através dos pareceres técnicos que fundamentam as licenças, e os modelos analíticos foi realizado nos estudos de caso elencados. Esses estudos se referem aos processos de licenciamento ambiental dos sistemas de esgotamento sanitário dos municípios de Barreiras, Luís Eduardo Magalhães, Sento Sé e Remanso. De forma geral, verificou-se que os pressupostos iniciais do trabalho não se mostraram evidentes, através da metodologia adotada. Em relação ao atendimento dos critérios elencados, evidenciou-se que, de forma geral o procedimento de licenciamento ambiental, da forma como seus preceitos conceituais são fundamentados, não é devidamente seguido, nos casos estudados. Tornou-se evidente a necessidade de medidas de aprimoramento na aplicação desse instrumento às estações de tratamento de esgoto.
5

INFLUÊNCIA DA TEMPERATURA SOBRE O PROCESSO DE DECOMPOSIÇÃO DOS ESGOTOS DOMESTICOS EM LAGOAS FACULTATIVAS / INFLUENCE OF THE TEMPERATURE UPON THE PROCESS OF WASTEWATER STABILIZATION IN FACULTATIVE PONDS

Klüsener, João Júlio 13 July 2006 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The increase of the urbanization added by little investments in sanitation is one of the main problems of public health in Brazil. One of the challenges of sanitation is to improve efficient treatment systems with low operational and implantation costs. This work analyzed the influence of the temperature upon the process of wastwater stabilization in a system of facultative ponds with the intention of contributing for the improvement of designing facultative ponds. It was used data of twenty years of sewer treatment plant of the Rosário do Sul city in Rio Grande do Sul. The bulletins report parameters of air temperature, sewer temperature, pH, dissolved oxygen, settleable solids, suspended solids, sulfides, and biological oxygen demand. As results, the correlations between the air temperature and the sewer temperature were established for three points on the system: entrance of the system; effluent of primary pond; effluent of secondary pond. It was verified that the parameters of DO, pH, and sulfides increased with the increase of temperature. The suspended sólids removal eficiency increase with the elevation of temperature, however it was not verified increase or decrease of settleable solids and BOD removal according to the variation of the temperature. It was also possible to stablish equations Ls = f(T), that relate the BOD surface loading that can be applied to a facultative pond with respect to the air temperature. These equations were the first ones based on data collected in Rio Grande do Sul. / O incremento da taxa de urbanização gerando cargas poluidoras pontuais cada vez maiores aliado aos poucos investimentos na área de saneamento constitui um dos principais problemas de saúde pública no país. Um dos desafios da área de saneamento é aperfeiçoar sistemas de tratamento que sejam eficientes e de baixos custos operacionais e de implantação. Este trabalho avaliou a influência da temperatura na decomposição de esgotos domésticos em um sistema de lagoas facultativas tendo como objetivo o aprimoramento dos métodos de dimensionamento deste tipo de lagoa de estabilização. Foram utilizados dados de vinte anos de monitoramento da estação de tratamentos de esgotos do município de Rosário do Sul RS, um dos mais antigos sistemas de lagoas de estabilização implantados no Brasil, que é operada pela CORSAN. Nos boletins de monitoramento constam parâmetros de temperatura do ar, temperatura do esgoto, pH, oxigênio dissolvido, sólidos sedimentáveis, sólidos suspensos, sulfetos, e demanda bioquímica de oxigênio. Como resultados, foram estabelecidas correlações entre a temperatura do ar e a temperatura do esgoto para três pontos do sistema: entrada do sistema; efluente lagoa primária; efluente lagoa secundária. Constatouse que os parâmetros de OD, pH e sulfetos, aumentaram significativamente com o aumento da temperatura. A eficiência de remoção de sólidos suspensos aumentou com a elevação da temperatura do ar, porém não se verificou aumento ou diminuição da remoção de sólidos sedimentáveis e DBO em função da temperatura. Também foi possível estabelecer equações Ls = f(T), que relacionam a máxima carga orgânica superficial que pode ser aplicada a uma lagoa facultativa em relação à temperatura do ar. Estas equações foram as primeiras definidas em função de dados coletados no Rio Grande do Sul.
6

Avaliação experimental para melhoria da eficiência da Ete do Conjunto Habitacional Ignez Andreazza em Areias (Compesa) através de estudo em Escala Piloto

SILVA, Maria de Fátima Barbosa da January 2005 (has links)
Made available in DSpace on 2014-06-12T18:07:06Z (GMT). No. of bitstreams: 2 arquivo7865_1.pdf: 950809 bytes, checksum: 017c08f8a7e33fa61e9eb18bba06f0e7 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2005 / Devido ao interesse social e ambiental em se expandir o número de comunidades atendidas por sistemas de esgotamento sanitário, constitui-se também um desafio projetar, construir e operar estações de tratamento eficientes e econômicas. Com base nesses argumentos e através de análises preliminares, escolheu-se para estudo, uma estação de tratamento de esgotos domésticos operada pela COMPESA que atende a aproximadamente 12.320 habitantes residentes no Conjunto Habitacional Ignez Andreazza, o maior da América Latina, situado em Areias-Recife-PE. Nesta estação de tratamento de efluentes (ETE) foi observado um baixo rendimento na remoção da Demanda Bioquímica de Oxigênio (DBO) em relação ao esperado em projeto, assim como problemas de recirculação e de baixa concentração de lodos ativados no tanque de aeração. Desta forma, este trabalho contribuiu para a melhoria do funcionamento desta ETE a partir de informações de monitoramento da mesma e estudos em unidades piloto. Foi realizada inicialmente uma avaliação através da caracterização dos efluentes e afluentes da mesma, utilizando a metodologia do Standard Methods for Water and Wastewater Examination (APHA et al., 1985). Foram analisados três pontos do sistema: entrada após a caixa de areia, o tanque de aeração e a saída do decantador. Em seguida foi realizado um estudo do processo de tratamento em uma unidade piloto constituída de um tanque de 21 litros, dotado de aeração por pedras porosas e um decantador, ambos de acrílico. A recirculação do lodo e a alimentação do substrato sintético foram realizadas utilizando uma bomba peristáltica. Foi também realizada uma avaliação do regime de escoamento nesta unidade piloto, através da técnica de DTR utilizando NaCl como traçador. Uma análise da influência da recirculação na performance do sistema pode ser realizada através de um segundo monitoramento dos mesmos pontos e tomando como base os resultados do primeiro estudo. A avaliação da cinética foi baseada em dados obtidos por respirometria, da degradação da matéria orgânica. Foi observada uma redução de 75% dos sólidos totais dissolvidos e uma remoção da DQO de cerca de 80%. No estudo no reator piloto, foi constatado um tempo de residência médio (tm) de 8,15h com variância (σ2) de 50,35 h2 para um tempo de retenção hidráulico teórico (TRH) de 10,5h. Aplicando-os no modelo de tanques em série, verificou-se que seriam necessários dois tanques ideais em série para modelar o reator real. Na operação do sistema piloto com a biomassa, após a estabilização do sistema, foram verificados valores de eficiências de 90 e 92% para a DBO e DQO respectivamente. No estudo cinético, foram utilizados como parâmetros a DQO e em seguida a concentração de biomassa. Devido a problemas de homogeneidade e representatividade na amostragem foi utilizada a técnica da determinação da Taxa de Consumo de Oxigênio (TCO) para se monitorar o avanço da degradação. Seis experimentos para determinação da TCO permitiram obter gráficos da TCO versus tempo, encontrando-se pelo método de cálculo integral um valor médio para a constante de velocidade (k) igual a 2,6, tendo sido considerado a reação como de 1ª ordem. Como reflexo do trabalho de monitoramento, a ETE estudada superou a eficiência de remoção de DBO estimada em projeto (94%) para 96% uma vez ativada a recirculação de lodo para o tanque aerado e realizadas as modificações sugeridas
7

Desenvolvimento de sistemas de controle ótimo para a operação de processos aeróbios de tratamento de esgotos / Development of optimal control system for the operation of aerobic wastewater treatment processes

Reis, José Antonio Tosta dos 17 January 2003 (has links)
Neste trabalho, a partir da aplicação da teoria de controle ótimo, são estabelecidos sistemas de controle aplicáveis a três importantes sistemas aeróbios de tratamento de esgotos - filtros biológicos, processos de lodos ativados e os processos combinados formados a partir da combinação dos filtros biológicos e lodos ativados. Para a definição dos sistemas de controle são necessários modelos dinâmicos que descrevam o comportamento dos diferentes sistemas de tratamento. Da literatura são obtidos os modelos dinâmicos destinados à descrição do comportamento do processo de lodos ativados; para o filtro biológico, é proposto um modelo combinando à equação de balanço do reator e o modelo de ordem variável, este último destinado ao cálculo do fluxo de substrato para o interior de biofilmes profundos. Os resultados demonstram que, independentemente do sistema de tratamento considerado, os sistemas de controle reduzem substancialmente os tempos de acomodação e os desvios apresentados pelas variáveis de estado em relação as suas condições de equilíbrio. Por fim, função da inviabilidade de monitoramento de todas as variáveis de estado utilizadas para caracterizar os sistemas de tratamento, são propostos, a partir de modelos simplificados, controladores que incorporam a observação de estados. Também neste caso, os controladores estabelecidos permitem melhorar significativamente o desempenho dos sistemas de tratamento de esgotos analisados. / This paper constructs automatic control systems by means of optimal control theory for three different combinations of wastewater treatment units, namely, trickling filter, activated sludge process and a combined process. The dynamic model for the activated sludge process available in literature and a model proposed for the trickling filter were used in the construction of control systems. It is shown that the controls obtained in this study substantially reduce the durations necessary for the reestablishment of the equilibrium conditions in terms of state variables and the attenuation of oscillations around these conditions. Controls including observers for the state variables were devised on the basis of simplified models for the process in order to deal with the difficulties involved in monitoring all the state variables. These control systems were also found to be quite effective in improving the performance of the wastewater treatment plants considered in this paper.
8

Desenvolvimento de sistemas de controle ótimo para a operação de processos aeróbios de tratamento de esgotos / Development of optimal control system for the operation of aerobic wastewater treatment processes

José Antonio Tosta dos Reis 17 January 2003 (has links)
Neste trabalho, a partir da aplicação da teoria de controle ótimo, são estabelecidos sistemas de controle aplicáveis a três importantes sistemas aeróbios de tratamento de esgotos - filtros biológicos, processos de lodos ativados e os processos combinados formados a partir da combinação dos filtros biológicos e lodos ativados. Para a definição dos sistemas de controle são necessários modelos dinâmicos que descrevam o comportamento dos diferentes sistemas de tratamento. Da literatura são obtidos os modelos dinâmicos destinados à descrição do comportamento do processo de lodos ativados; para o filtro biológico, é proposto um modelo combinando à equação de balanço do reator e o modelo de ordem variável, este último destinado ao cálculo do fluxo de substrato para o interior de biofilmes profundos. Os resultados demonstram que, independentemente do sistema de tratamento considerado, os sistemas de controle reduzem substancialmente os tempos de acomodação e os desvios apresentados pelas variáveis de estado em relação as suas condições de equilíbrio. Por fim, função da inviabilidade de monitoramento de todas as variáveis de estado utilizadas para caracterizar os sistemas de tratamento, são propostos, a partir de modelos simplificados, controladores que incorporam a observação de estados. Também neste caso, os controladores estabelecidos permitem melhorar significativamente o desempenho dos sistemas de tratamento de esgotos analisados. / This paper constructs automatic control systems by means of optimal control theory for three different combinations of wastewater treatment units, namely, trickling filter, activated sludge process and a combined process. The dynamic model for the activated sludge process available in literature and a model proposed for the trickling filter were used in the construction of control systems. It is shown that the controls obtained in this study substantially reduce the durations necessary for the reestablishment of the equilibrium conditions in terms of state variables and the attenuation of oscillations around these conditions. Controls including observers for the state variables were devised on the basis of simplified models for the process in order to deal with the difficulties involved in monitoring all the state variables. These control systems were also found to be quite effective in improving the performance of the wastewater treatment plants considered in this paper.
9

A importância das estações de tratamento de esgotos da SABESP (Companhia de Saneamento Básico do Estado de São Paulo) de Adamantina para o Saneamento Básico na UGHRI (Unidade de Gerenciamento de Recursos Hídricos) Aguapeí/Peixe do Estado de São Paulo, Brasil /

Villagra, Julio Cesar January 2018 (has links)
Orientador: Raul Borges Guimarães / Resumo: O presente trabalho discute a importância do Saneamento Básico a partir da implantação de estações de tratamento de esgotos no município de Adamantina, localizadas na UGRHI Aguapeí/Peixe do Estado de São Paulo, operadas pela SABESP (Companhia de Saneamento Básico do Estado de São Paulo) para melhoria das condições e padrões de lançamento de efluentes nos corpos receptores. Com base nesta análise, proporemos ações de aperfeiçoamento dos processos, bem como a disseminação das informações de benfeitorias ao meio ambiente oriundas de implantação de obras similares. / Abstract: The present work discusses the importance of basic sanitation from the implantation of sewage treatment plants in the municipality of Adamantina, located at UGRHI Aguapeí / Peixe of the State of São Paulo, operated by SABESP (Basic Sanitation Company of the State of São Paulo) to improve the conditions and patterns of effluent release in the recipient bodies. Based on this analysis we propose actions to improve the processes, as well as the dissemination of information on improvements to the environment arising from the implementation of similar works. / Mestre
10

Reúso de água e aquicultura: inativação de fármacos e interferentes endócrinos pelo processo foto-Fenton solar / Water reuse: inactivation of pharmaceuticals and endocrine disruptors by the solar photo-Fenton process

Verdicchio, Letícia 14 July 2017 (has links)
A presença de poluentes em concentrações na faixa de ng L-1 e µg L-1 nos diferentes tipos de água é uma grande preocupação ambiental porque podem apresentar efeitos nocivos aos seres vivos e os sistemas convencionais de tratamento de água e esgoto não são eficientes em removê-los. Os processos oxidativos avançados (POA) são considerados métodos eficazes para a degradação desse tipo de contaminantes e podem ser utilizados para tratar efluentes com a finalidade de reúso em diferentes aplicações como, por exemplo, agricultura ou aquicultura. Assim, o objetivo desta Dissertação foi avaliar a inativação de fármacos e interferentes endócrinos, em um reator tipo coletor parabólico composto, pelo processo foto-Fenton mediado por radiação solar em efluente de estação de tratamento de esgoto. Primeiramente, foi construído o reator, estabelecida a extração em fase sólida como a técnica aplicada para o preparo das amostras a serem analisadas por CLAE/DAD e desenvolvido o método para identificação de sete contaminantes (sulfatiazol, sulfamezarina, sulfadimetoxina, sulfametoxazol, metilparabeno, propilparabeno e naproxeno) no efluente de estação de tratamento de esgoto. Na sequência, foram realizados experimentos com o intuito de otimizar o tratamento e estabeleceram-se as concentrações de H2O2 e ferro (III). Por fim, foram realizados ensaios cinéticos e, adicionalmente, testes ecotoxicológicos para avaliar a ecotoxicidade do efluente antes e depois de 300 min do tratamento foto-Fenton solar. Os resultados mostraram que mesmo após 300 min de reação não houve a completa degradação dos contaminantes, entretanto, o efluente tratado não se mostrou prejudicial aos organismos Daphnia similis e Lactuca sativa. / Currently, the presence of pollutants in concentrations ranging from ng L-1 to µg L-1 in different types of waters constitutes a major environmental concern as they can be harmful to living beings and conventional water and wastewater treatment systems are not efficient in removing them. Advanced oxidation processes are effective methods for the degradation of this type of contaminants and can be applied to wastewater treatments for beneficial water reuse purposes such as agriculture or aquaculture. Thus, the aim of this study was to evaluate the inactivation of some pharmaceuticals and endocrine disruptors, by using a compound parabolic collector reactor, by solar photo-Fenton in municipal wastewater treatment plant effluent. First of all, the reactor was constructed, solid phase extraction (SPE) was determined as the technique used to prepare the samples to be analyzed by HPLC/DAD and the methodology to identify the seven contaminants (sulfathiazole, sulfamerazine, sulfadimethoxine, sulfamethoxazole, methylparaben, propylparaben, and naproxen) in the WWTP effluent was developed. Then, experiments were carried out with the purpose of optimizing the treatment and the concentrations of H2O2 and iron(III) were established. Finally, kinetic tests and, additionally, ecotoxicological assays were carried out to evaluate the effluent ecotoxicity before and after 300 min of the solar photo-Fenton treatment. It has been observed that even after 300 min of reaction there was an incomplete degradation of the pollutants, however, the treated effluent was not harmful to the test-organisms Daphnia similis and Lactuca sativa.

Page generated in 0.0896 seconds