• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • Tagged with
  • 9
  • 9
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do uso de fibras minerais naturais na remoção do octilfenol polietóxido etanol de soluções aquosas

Ribeiro, Daniel Alexandre de Marçal January 2006 (has links)
No description available.
2

Determinação de estrogénios em águas de uma ETAR por GC-MS

Ramos, Ana Isabel Martins Casal January 2008 (has links)
No description available.
3

Influência do aporte de águas pluviais nos parâmetros da qualidade das águas residuárias da ETE Vista Verde.

Alexander Antonio Peres Gutiérrez Aguiñada 14 February 2008 (has links)
Para a coleta das águas residuárias e águas pluviais de uma comunidade e o transporte adequado para uma estação de tratamento de esgoto ou lançamento final, pode-se utilizar três tipos de sistema de esgotamento: sistema unitário, sistema separador parcial ou misto e sistema separador absoluto, sendo que no Brasil a legislação estabelece que seja adotado o sistema separador absoluto, concebido para coletar apenas as águas residuárias. Entretanto, na prática isto não ocorre, devido às ligações clandestinas de águas pluviais geradas pela falta de fiscalização e à ausência de redes de águas residuárias que atendam toda a população, gerando problemas na operação das Estações de Tratamento de Esgotos, por não suportarem o aumento da vazão afluente, ocorre a sobrecarga hidráulica e arraste de materiais sólidos das tubulações pluviais para Estações de Tratamento de Esgotos. O presente trabalho busca avaliar a qualidade dos esgotos combinados da Estação de Tratamento de Esgoto Vista Verde na cidade de São José dos Campos em períodos secos e chuvosos, a fim de analisar os impactos do aporte de águas pluviais, verificar se os mesmos se enquadram na RESOLUÇÃO DO CONAMA N 357 de 17 de Março de 2005 e fornecer propostas para mitigar os impactos gerados pelas tormentas na operação e no processo de tratamento de esgotos. Para isso contamos com a colaboração da SABESP que forneceu dados diários de vazão, oxigênio dissolvido, pH e sólidos sedimentáveis. Também foi realizado um trabalho de campo afim de conhecer o local e realizar coleta dos parâmetros (DBO, DQO, OD, pH, sólidos sedimentáveis e sólidos suspensos). Pode-se concluir que os efeitos da água pluvial nos parâmetros analisados influenciam na operação da ETE Vista Verde, mas não é a única responsável pela alteração na operação, pois a própria operação da ETE demonstra-se ineficiente mesmo em períodos de seca, tendo como outro responsável seu critério de operação; cabendo reavaliar os critérios de operação da mesma (aeradores). Os parâmetros DBO e OD não se enquadraram à legislação em vigor sendo que apenas o pH atendeu os padrões estabelecidos. Para solução do problema sugere-se uma reavaliação da operação dos aeradores, ou a implantação das técnicas alternativas lineares de drenagem urbana, que demonstram grandes eficiências de remoção da poluição contida no escoamento superficial.
4

Desenvolvimento de um sistema para avaliação do efeito da aplicação de processos oxidativos avançados no tratamento de efluentes líquidos contendo fenol ou cianeto / Development of a system to evaluate the effect of the application of advanced oxidative processes in the treatment of liquid effluents containing phenol or cyanide

Nolasco, Felipe Rufine 18 September 2009 (has links)
Com o intuito de viabilizar, ambiental e economicamente, a degradação de algumas substâncias perigosas e recalcitrantes, presentes em águas e efluentes, foi desenvolvido um sistema para estudar a tratabilidade dessas substâncias, utilizando Processos Oxidativos Avançados POAs. As espécies escolhidas foram o fenol (C6H5OH) a 50 mg L-1 e o cianeto de potássio (KCN) a 20 mg L-1. Os resíduos químicos foram submetidos a tratamentos com diferentes doses de O3 (0, 2,4 e 4,8 g h-1), H2O2 (0, 150 e 300 mg L-1 para o fenol e 0, 60 e 120 mg L-1 para o cianeto) e UV (0, 8 e 32 watts), pois tais combinações promovem a geração de radicais hidroxila (OH), cujo potencial de oxidação é superior ao de cada oxidante individualmente. O sistema desenvolvido funciona em batelada com recirculação, possibilitando todas as combinações de interesse entre os oxidantes, com capacidade máxima de 300 mL de resíduo, volume adotado para todos os testes deste trabalho. O sistema é composto por uma coluna cilíndrica disposta na posição vertical, ligada a um reator UV. Outros equipamentos instalados são a bomba para a circulação do resíduo, o concentrador de O2, o ozonizador (0-24 g h-1), cujo gás é insuflado pela base da coluna, e seu excesso passa pelo destruidor de O3, composto por uma coluna preenchida com carvão ativado. A solução de H2O2 é adicionada ao sistema com o auxílio de uma seringa. A eficiência do processo de mineralização do fenol, foi avaliada através de 27 tratamentos (combinações) nos tempos de 15 e 30 minutos e pH 6,5. As amostras coletadas foram analisadas em equipamento Shimadzu TOC-5000A, obtendo-se a concentração de carbono orgânico total. Os dados foram submetidos à análise estatística (Fatorial e teste de Tukey, p<0,05). As combinações com os melhores resultados foram utilizadas para uma segunda etapa de testes, variando os tempos em 5, 15, 30 e 45 minutos. Os novos dados foram submetidos à análise estatística e, novamente, as combinações com melhores resultados foram utilizadas para avaliação do efeito do pH (6,5 e 9,5) na mineralização do fenol. A combinação O3 (4,8 g h-1) / UV (32 watts) / H2O2 (300 mg L-1), em pH 9,5, apresentou a melhor condição de tratamento em 30 minutos, proporcionando 99,7% de mineralização do fenol. O delineamento experimental do cianeto foi baseado nas melhores razões oxidante/resíduo obtidas para o fenol. Foi preparada solução 8,13 mg L-1 de CN previamente alcalinizada (pH 11,0). Os tempos estudados foram 1, 2, 4, 5 e 10 minutos e as amostras foram submetidas à análise de N-NO3 por espectrofotometria em sistema por análise em fluxo. Neste caso a combinação O3 (4,8 g h-1) / UV (32 watts), proporcionou 97,6% da oxidação do cianeto à NO3 em 7 minutos de tratamento. Os custos dos tratamentos nas melhores condições foram de R$ 11,08 por litro de fenol tratado e R$ 4,20 por litro de cianeto tratado. Concluiu-se que o sistema proposto foi eficiente no tratamento de ambos resíduos químicos (fenol e cianeto) em um curto período de tempo / In order to facilitate, environmentally and economically, the degradation of some hazardous and recalcitrant substances, presented in waters and wastewaters, a system was developed to study the treatability of chemical substances using Advanced Oxidative Processes AOPs. The substances chosen were phenol (C6H5OH) at 50 mg L-1 and potassium cyanide (KCN) at 20 mg L-1. The chemical residues were submitted to treatments with different combinations and doses of O3 (0, 2.4, and 4.8 g h-1), H2O2 (0, 150 and 300 mg L-1 for phenol and 0, 60 and 120 mg L-1 for cyanide) and ultraviolet radiation (0, 8 and 32 watts), as these combinations promote the generation of hydroxyl radicals (OH), whose oxidation potential is greater than of each oxidant individually. The developed system works in batch treatments with recirculation, allowing all combinations of interests among the oxidants, with a maximum capacity of 300 mL of waste, adopted for all tests of this work. The system consists of a cylindrical column disposed in the vertical position and connected to a UV reactor. Other installed equipments are the pump for residual recirculation, the O2 concentrator, the ozonator (0-24 g h-1), which gas is blown from the base of the column and its excess is destroyed by the equipment composed of a glass column filled with granulate activated carbon. The solution of H2O2 is added to the system with the aid of a syringe. The efficiency of the mineralization of phenol was evaluated in 27 treatments in 15 and 30 minutes and pH 6.5. The collected samples were analyzed in Shimadzu TOC 5000A equipment, obtaining the concentration of total organic carbon (TOC). The obtained data were submitted to statistical analysis (Factorial and Tukey test, p<0.05). The combinations with the best results were used for a second phase of tests, varying the time at 5, 15, 30, and 45 minutes. The new data were submitted to statistical analysis and the best performing combinations were used to evaluate the effect of pH (6.5 and 9.5) in the mineralization of phenol. The combination of O3 (4.8 g h-1) / UV (32 watts) / H2O2 (300 mg L-1) at pH 9.5 showed the best treatment condition in 30 minutes, providing 99.7% of phenol mineralization. The experimental design of cyanide was based on the best oxidant/residue reasons obtained for phenol. A solution with 8.13 mg L-1 of CN previously alkaline (pH 11.0) was prepared. The treatment times were 1, 2, 4, 5 and 10 minutes and the samples were submitted to N-NO3 analysis by spectrophotometry system in flow injection analysis. In this case the combination O3 (4.8 g h-1) / UV (32 watts) provided 97.6 % of oxidation of the cyanide to NO3 in 7 minutes of treatment. The costs of treatments in the best conditions were R$ 11,08 per litter of phenol treated and R$ 4,20 per litter of cyanide treated. It can be concluded that the proposed system was effective in the treatment of both chemical residues (phenol and cyanide) in a short period of time
5

Desenvolvimento de um sistema para avaliação do efeito da aplicação de processos oxidativos avançados no tratamento de efluentes líquidos contendo fenol ou cianeto / Development of a system to evaluate the effect of the application of advanced oxidative processes in the treatment of liquid effluents containing phenol or cyanide

Felipe Rufine Nolasco 18 September 2009 (has links)
Com o intuito de viabilizar, ambiental e economicamente, a degradação de algumas substâncias perigosas e recalcitrantes, presentes em águas e efluentes, foi desenvolvido um sistema para estudar a tratabilidade dessas substâncias, utilizando Processos Oxidativos Avançados POAs. As espécies escolhidas foram o fenol (C6H5OH) a 50 mg L-1 e o cianeto de potássio (KCN) a 20 mg L-1. Os resíduos químicos foram submetidos a tratamentos com diferentes doses de O3 (0, 2,4 e 4,8 g h-1), H2O2 (0, 150 e 300 mg L-1 para o fenol e 0, 60 e 120 mg L-1 para o cianeto) e UV (0, 8 e 32 watts), pois tais combinações promovem a geração de radicais hidroxila (OH), cujo potencial de oxidação é superior ao de cada oxidante individualmente. O sistema desenvolvido funciona em batelada com recirculação, possibilitando todas as combinações de interesse entre os oxidantes, com capacidade máxima de 300 mL de resíduo, volume adotado para todos os testes deste trabalho. O sistema é composto por uma coluna cilíndrica disposta na posição vertical, ligada a um reator UV. Outros equipamentos instalados são a bomba para a circulação do resíduo, o concentrador de O2, o ozonizador (0-24 g h-1), cujo gás é insuflado pela base da coluna, e seu excesso passa pelo destruidor de O3, composto por uma coluna preenchida com carvão ativado. A solução de H2O2 é adicionada ao sistema com o auxílio de uma seringa. A eficiência do processo de mineralização do fenol, foi avaliada através de 27 tratamentos (combinações) nos tempos de 15 e 30 minutos e pH 6,5. As amostras coletadas foram analisadas em equipamento Shimadzu TOC-5000A, obtendo-se a concentração de carbono orgânico total. Os dados foram submetidos à análise estatística (Fatorial e teste de Tukey, p<0,05). As combinações com os melhores resultados foram utilizadas para uma segunda etapa de testes, variando os tempos em 5, 15, 30 e 45 minutos. Os novos dados foram submetidos à análise estatística e, novamente, as combinações com melhores resultados foram utilizadas para avaliação do efeito do pH (6,5 e 9,5) na mineralização do fenol. A combinação O3 (4,8 g h-1) / UV (32 watts) / H2O2 (300 mg L-1), em pH 9,5, apresentou a melhor condição de tratamento em 30 minutos, proporcionando 99,7% de mineralização do fenol. O delineamento experimental do cianeto foi baseado nas melhores razões oxidante/resíduo obtidas para o fenol. Foi preparada solução 8,13 mg L-1 de CN previamente alcalinizada (pH 11,0). Os tempos estudados foram 1, 2, 4, 5 e 10 minutos e as amostras foram submetidas à análise de N-NO3 por espectrofotometria em sistema por análise em fluxo. Neste caso a combinação O3 (4,8 g h-1) / UV (32 watts), proporcionou 97,6% da oxidação do cianeto à NO3 em 7 minutos de tratamento. Os custos dos tratamentos nas melhores condições foram de R$ 11,08 por litro de fenol tratado e R$ 4,20 por litro de cianeto tratado. Concluiu-se que o sistema proposto foi eficiente no tratamento de ambos resíduos químicos (fenol e cianeto) em um curto período de tempo / In order to facilitate, environmentally and economically, the degradation of some hazardous and recalcitrant substances, presented in waters and wastewaters, a system was developed to study the treatability of chemical substances using Advanced Oxidative Processes AOPs. The substances chosen were phenol (C6H5OH) at 50 mg L-1 and potassium cyanide (KCN) at 20 mg L-1. The chemical residues were submitted to treatments with different combinations and doses of O3 (0, 2.4, and 4.8 g h-1), H2O2 (0, 150 and 300 mg L-1 for phenol and 0, 60 and 120 mg L-1 for cyanide) and ultraviolet radiation (0, 8 and 32 watts), as these combinations promote the generation of hydroxyl radicals (OH), whose oxidation potential is greater than of each oxidant individually. The developed system works in batch treatments with recirculation, allowing all combinations of interests among the oxidants, with a maximum capacity of 300 mL of waste, adopted for all tests of this work. The system consists of a cylindrical column disposed in the vertical position and connected to a UV reactor. Other installed equipments are the pump for residual recirculation, the O2 concentrator, the ozonator (0-24 g h-1), which gas is blown from the base of the column and its excess is destroyed by the equipment composed of a glass column filled with granulate activated carbon. The solution of H2O2 is added to the system with the aid of a syringe. The efficiency of the mineralization of phenol was evaluated in 27 treatments in 15 and 30 minutes and pH 6.5. The collected samples were analyzed in Shimadzu TOC 5000A equipment, obtaining the concentration of total organic carbon (TOC). The obtained data were submitted to statistical analysis (Factorial and Tukey test, p<0.05). The combinations with the best results were used for a second phase of tests, varying the time at 5, 15, 30, and 45 minutes. The new data were submitted to statistical analysis and the best performing combinations were used to evaluate the effect of pH (6.5 and 9.5) in the mineralization of phenol. The combination of O3 (4.8 g h-1) / UV (32 watts) / H2O2 (300 mg L-1) at pH 9.5 showed the best treatment condition in 30 minutes, providing 99.7% of phenol mineralization. The experimental design of cyanide was based on the best oxidant/residue reasons obtained for phenol. A solution with 8.13 mg L-1 of CN previously alkaline (pH 11.0) was prepared. The treatment times were 1, 2, 4, 5 and 10 minutes and the samples were submitted to N-NO3 analysis by spectrophotometry system in flow injection analysis. In this case the combination O3 (4.8 g h-1) / UV (32 watts) provided 97.6 % of oxidation of the cyanide to NO3 in 7 minutes of treatment. The costs of treatments in the best conditions were R$ 11,08 per litter of phenol treated and R$ 4,20 per litter of cyanide treated. It can be concluded that the proposed system was effective in the treatment of both chemical residues (phenol and cyanide) in a short period of time
6

Ciclagem de nutrientes e crescimento de plantas em solos irrigados com águas residuais da extração de petróleo / Mineralization of nutrients and plant growth in soils irrigated with wastewater from oil extraction

Sousa, Adervan Fernandes January 2016 (has links)
SOUSA, Adervan Fernandes. Ciclagem de nutrientes e crescimento de plantas em solos irrigados com águas residuais da extração de petróleo. 2016. 74 f. Tese (Doutorado em ecologia e recursos naturais)- Universidade Federal do Ceará, Fortaleza-CE, 2016. / Submitted by Elineudson Ribeiro (elineudsonr@gmail.com) on 2016-05-31T17:46:23Z No. of bitstreams: 1 2016_tese_afsousa.pdf: 1242984 bytes, checksum: 1d234f0360c05217baa63e8afaa060be (MD5) / Approved for entry into archive by José Jairo Viana de Sousa (jairo@ufc.br) on 2016-05-31T22:35:26Z (GMT) No. of bitstreams: 1 2016_tese_afsousa.pdf: 1242984 bytes, checksum: 1d234f0360c05217baa63e8afaa060be (MD5) / Made available in DSpace on 2016-05-31T22:35:26Z (GMT). No. of bitstreams: 1 2016_tese_afsousa.pdf: 1242984 bytes, checksum: 1d234f0360c05217baa63e8afaa060be (MD5) Previous issue date: 2016 / The large volume of water used in agriculture compromises its availability for human consumption. Faced with this problem, it is necessary to evaluate the use of wastewater in agricultural production as an option for the conservation of water resources. Wastewater from oil fields can be a good choice for irrigation, especially in regions of low or high rainfall variability, as in the Brazilian Northeast. However, it is necessary to evaluate its effects on the soil, such as the accumulation of nutrients and decomposition of organic matter, as well as the nutritional aspect and plant growth. The aims of this study were: i) to assess the changes that take place in the soluble salts and soil organic matter fractions, and in the growth of plants of the BRS 321 cultivar of the sunflower (Helianthus annuus L.) cultivated in soil of a sandy texture and irrigated with wastewater obtained from oil extraction and treated by filtration and reverse osmosis; ii) to assess the nutritional changes in the BRS 321cultivar of the sunflower (Helianthus annuus) irrigated with wastewater from oil extraction, and the effects on biomass and achene production; and iii) to evaluate the decomposition of plant residue from the BRS 321 cultivar of the sunflower (Helianthus annuus) in areas irrigated with wastewater from oil extraction. The sunflower was grown for three successive periods in areas irrigated with wastewater from oil extraction treated by filtering (APF) and reverse osmosis (APO), or with groundwater from the Açu aquifer (ACA). At the end of each cycle, pH values were determined, together with electrical conductivity (EC), the sodium adsorption ratio (SAR) and the levels of Na, Cl, Mg, Ca, K, HCO3-, Ag, As, B, Ba, Cd, Co, Cr3+, Hg, Ni, Pb, Zn, and of C in the humic fractions. The concentrations of N, P, K, Ca, Mg, S and Na were determined in the roots, shoots and achenes, along with growth and the accumulation of biomass. In addition, the decomposition of shoot residue from the sunflower plants was evaluated. Changes were seen in the chemical properties of the soil, highlighting an increase in salts, which was greater in the areas irrigated with APF; a rise was also seen in pH irrespective of the type of water used. The rise in soil salinity and alkalinity reduced the growth and accumulation of plant biomass. Moreover, irrigation resulted in nutritional changes in the plants, which were reflected in the growth and production of achenes, and in the decomposition of the plant residue, having positive or negative effects according to the treatment of the wastewater. It was concluded that wastewater from oil extraction used in irrigation affects the chemical properties of the soil as well as the nutritional composition and development of the plants, especially when irrigated with APF. Furthermore, irrigation with wastewater changed the mineralisation of the sunflower plant residue, but not the decomposition of the organic carbon in the humic fractions. / O grande volume de água utilizado na agricultura compromete a sua disponibilidade para o consumo humano. Diante desse problema, é necessário avaliar a utilização de águas residuais na produção agrícola, como uma opção para a conservação dos recursos hídricos. Águas residuais oriundas de campos de petróleo podem ser uma boa opção para irrigação, especialmente em regiões de pouca e alta variabilidade de chuvas como o Nordeste brasileiro. No entanto, é necessário avaliar os seus efeitos no solo, como acúmulo de nutrientes e decomposição da matéria orgânica, bem como no aspecto nutricional e no crescimento das plantas. Os objetivos deste trabalho foram: i) Avaliar as mudanças ocorridas nos sais solúveis e nas frações da matéria orgânica do solo e no crescimento de plantas de girassol (Helianthus annuus L.) cv. BRS 321, cultivadas em solo de textura arenosa irrigado com água residual oriunda da extração de petróleo tratada por filtragem e osmose reversa; ii) Avaliar as alterações nutricionais do girassol (Helianthus annuus) BRS 321 irrigado com água residual da extração de petróleo e os efeitos sobre a produção de biomassa e de aquênios; e iii) Avaliar a decomposição dos restos culturais de girassol (Helianthus annuus) cv. BRS 321 em áreas irrigadas com água residual da extração de petróleo. O girassol foi cultivado durante três períodos sucessivos em áreas irrigadas com água residual da extração de petróleo tratada por filtragem (APF) e por osmose reversa (APO) ou água subterrânea do aquífero Açu (ACA). Ao fim de cada ciclo foram determinados os valores de pH, condutividade elétrica (CE), a razão de adsorção de sódio (RAS) e os teores de Na, Cl, Mg, Ca, K, HCO3-, Ag, As, B, Ba, Cd, Co, Cr3+, Hg, Ni, Pb, Zn, além de C nas frações húmicas. Em raízes, parte aérea e aquênios determinaram-se os teores de N, P, K, Ca, Mg, S e Na e avaliaram-se o crescimento e o acúmulo de biomassa. Além disso, avaliou-se a decomposição dos resíduos da parte aérea das plantas de girassol. Houve alterações nos atributos químicos do solo, em destaque o acréscimo de sais, que foi maior nas áreas irrigadas com APF, e elevação do pH, independente do tipo de água utilizado. A elevação da salinidade e alcalinidade do solo reduziu o crescimento e o acúmulo de biomassa das plantas. Além disso, a irrigação proporcionou alterações nutricionais das plantas, que refletiram no crescimento e na produção de aquênios do girassol e na decomposição dos resíduos da cultura, com efeitos positivos ou negativos, conforme o tratamento da água residual. Concluiu-se que a água residual da extração de petróleo utilizada na irrigação afeta os atributos químicos do solo, bem como a composição nutricional e o desenvolvimento das plantas, principalmente quando irrigadas com a APF. Além disso, a irrigação com água residual alterou a mineralização dos resíduos vegetais do girassol, mas não a de decomposição do carbono orgânico nas frações húmicas.
7

Biogrânulos aeróbicos em reator seqüencial em batelada para o tratamento de efluente de biodigestor proveniente da suinocultura / Aerobic biogranules in sequential batch reactor for the treatment of anaerobic digester effluent from the piggish

Pujol, Stefen Barbosa 17 March 2008 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The fermentation of pig slurry into anaerobic digesters has been a recommended practice for the energetic utilization of the produced methane (CH4), thus reducing the emission of this greenhouse gas into the atmosphere. However, the wastewater (effluent of the digester), if dumped in the current water, can cause pollution because it has Chemical Oxygen Demand (COD) and ammoniacal N levels higher than the slurries in natura, besides the phosphorus, presence of odor and pathogens. This study had as objective to evaluate the efficiency of a sequential batch reactor (SBR) of aerobic biogranules in the treatment of anaerobic digester effluents fed with pigs slurry. For that, a study was done in the Soil and Environmental Microbiology Laboratory, in Universidade Federal de Santa Maria, Santa Maria RS, Brazil. The SBR was operated for 88 days, with three daily cycles of 8 h, with different sequential stages: without air supply, with air supply and without air supply. During this period the efficiency of the process in the removal of the COD, Total Kjeldahl Nitrogen (TKN), nitric N and ammoniacal N, total Phosphorus (total P), Total Solids (TS), pH and odor were evaluated. The removal efficiency was of 52% for COD, 37% for total P and approximately 72% for TKN, ammoniacal N and TS. The effluent of the reactor did not show noticeable odor. The nitrification was the major process in the removal of the ammoniacal N during the treatment in aerobic granules reactor of the wastewater from anaerobic digestion of pigs slurries. Although the resulting effluent still needs a post-treatment to be dumped in the environmental, the use of aerobic biogranules in SBR showed to be a promising biotechnology for the pollutant removal of the evaluated wastewater. / A fermentação dos dejetos de suínos em biodigestores vem sendo recomendada para o aproveitamento energético do metano (CH4) produzido, diminuindo assim a emissão desse gás de efeito estufa para a atmosfera. Entretanto, a água residual (efluente de biodigestor), se despejada em cursos d água, pode causar poluição pois apresenta, ainda, Demanda Química de Oxigênio (DQO) e teores de N amoniacal mais elevados do que os dejetos in natura, além da concentração residual de fósforo e presença de odores e patógenos. Este trabalho teve como objetivo avaliar a eficiência de um reator seqüencial em batelada (RSB), de biogrânulos aeróbicos, no tratamento de efluente de biodigestor anaeróbico alimentado com dejetos de suínos. Para isso, foi conduzido um experimento no Laboratório de Microbiologia do Solo e do Ambiente, na Universidade Federal de Santa Maria (UFSM), Santa Maria RS, Brasil. O RSB foi operado por 88 dias, com três ciclos diários de oito horas, sendo que em cada ciclo havia fases seqüenciais distintas: sem aeração, com aeração e sem aeração. Durante esse período avaliou-se a eficiência do processo na remoção de DQO, Nitrogênio Total Kjeldahl (NTK), N amoniacal e N nítrico, Fósforo Total (P total), Sólidos Totais (ST) e odor. A eficiência de remoção foi de 52% para DQO, 37% para P total e próxima a 72% para NTK, N amoniacal e ST. O efluente do reator não apresentou odor perceptível. A nitrificação constituiu-se no principal processo de remoção de N amoniacal durante o tratamento, em reator aeróbico de biogrânulos, da água residual proveniente da biodigestão anaeróbica de dejetos de suínos. Embora o efluente resultante ainda necessite de tratamento complementar para ser despejado no ambiente, o uso de biogrânulos aeróbicos em RSB mostrou ser uma biotecnologia promissora para a remoção de poluentes da água residual avaliada.
8

Efluentes do processamento de Minced de tilápia reaproveitados como coprodutos com atividade antioxidante e para uso como meio de cultura em bioprocessos / Effluent of processing Minced tilapia reutilized as co-products with antioxidant activity and for use as culture medium in bioprocesses

Leite, Suzan Blima Paulino 31 May 2016 (has links)
A água residual do processamento do Minced de tilápia (Oreochromis niloticus) é descartada sem qualquer aproveitamento, constituindo um efluente de potencial impacto ao ambiente. O objetivo desse estudo foi avaliar este efluente, caracterizar sua fração proteica, verificar seu potencial antioxidante e sua eficiência como meio de cultura para o crescimento microbiano. A carne mecanicamente separada (CMS) de tilápia foi submetida à operação de clarificação em água destilada a 10ºC, na proporção 1:3, processo que se constituiu em homogeneização por 3 min, repouso por 3 min, sendo o Minced acondicionado e prensado em tecido de algodão esterilizado para drenagem da água residual. O efluente gerado pela etapa de lavagem do Minced apresentou 8854,5 mgO2/L de DQO e 4656,88 mgO2/L de DBO, valores considerados elevados dentre os padrões de qualidade, devido ao alto teor de matéria orgânica. O efluente foi submetido à centrifugação e a fração aquosa foi liofilizada, sendo designada de peptona e submetida à análise eletroforética que apresentou maior concentração de proteínas na faixa de 47-60 kDa. A atividade antioxidante foi avaliada em diferentes concentrações utilizando ensaios in vitro como o método do radical 2,2-azinobis-(3-etilbenzotiazoline-6-ácido sulfônico) (ABTS) e 1,1-difenil-2-picrilhidrazil (DPPH), sendo que, em ambos, o aumento da atividade antioxidante acompanhou a concentração. Com destaque para o extrato 15 mg/ml que propiciou 46,23% de inibição do radical ABTS, e 83,22% em DPPH. Em relação ao teste de efetividade, foram comparadas peptonas comerciais e a peptona da água residual liofilizada, sendo avaliada a curva de crescimento pela densidade óptica, produção de biomassa e detecção por plaqueamento da Escherichia coli e Staphylococcus aureus. A performance obtida nas peptonas da água residual foram superiores às comerciais, evidenciando o vantajoso reuso desse efluente como coproduto destinado ao cultivo de microrganismos. O desempenho do peptídeo residual permite que se recomende o seu uso por parte das empresas que buscam a ecoeficiência / The wastewater of minced tilapia (Oreochromis niloticus) processing is discarded without any use, constituting a effluent of potential impact on the environment. The aim of this study was to evaluate this effluent, characterize its protein fraction, verify its antioxidant potential and its efficiency as a culture medium for microbial growth. Mechanically separated meat (CMS) tilapia was submitted to clarification operation in distilled water at 10°C in a 1:3 ratio, a process that constitutes homogenizing for 3 minutes, rest for 3 minutes, and the minced packed and compressed in a sterilized cotton fabric for drainage of wastewater. The effluent generated by the minced washing step showed 8854.5 mgO2 / L of COD and 4656.88 mgO2 / L BOD, values considered among high quality standards due to the high content of organic matter. The effluent was subjected to centrifugation and the aqueous fraction was lyophilized, and designated peptone and subjected to electrophoresis analysis showed a higher concentration of proteins in the 47-60 kDa range. The antioxidant activity was evaluated at different concentrations using in vitro assays such as radical method 2,2-azinobis- (3-sulphonic acid 6-etilbenzotiazoline) (ABTS), and 1,1-diphenyl-2-picrylhydrazyl (DPPH), wherein, in both the increased antioxidant activity followed the concentration. Especially the extract 15 mg / ml which provided 46.23% inhibition of ABTS radical, and 83.22% in DPPH. Regarding the effectiveness test, they were compared to commercial peptones and peptone lyophilized wastewater, assessing growth curves by optical density biomass production by plating and detection of Escherichia coli and Staphylococcus aureus. The performance achieved in peptones wastewater were higher than commercial, showing the beneficial reuse of the effluent as a co-product intended for microorganisms cultivation. The performance of the residual peptide allows recommending its use by businesses seeking eco-efficiency
9

Efluentes do processamento de Minced de tilápia reaproveitados como coprodutos com atividade antioxidante e para uso como meio de cultura em bioprocessos / Effluent of processing Minced tilapia reutilized as co-products with antioxidant activity and for use as culture medium in bioprocesses

Suzan Blima Paulino Leite 31 May 2016 (has links)
A água residual do processamento do Minced de tilápia (Oreochromis niloticus) é descartada sem qualquer aproveitamento, constituindo um efluente de potencial impacto ao ambiente. O objetivo desse estudo foi avaliar este efluente, caracterizar sua fração proteica, verificar seu potencial antioxidante e sua eficiência como meio de cultura para o crescimento microbiano. A carne mecanicamente separada (CMS) de tilápia foi submetida à operação de clarificação em água destilada a 10ºC, na proporção 1:3, processo que se constituiu em homogeneização por 3 min, repouso por 3 min, sendo o Minced acondicionado e prensado em tecido de algodão esterilizado para drenagem da água residual. O efluente gerado pela etapa de lavagem do Minced apresentou 8854,5 mgO2/L de DQO e 4656,88 mgO2/L de DBO, valores considerados elevados dentre os padrões de qualidade, devido ao alto teor de matéria orgânica. O efluente foi submetido à centrifugação e a fração aquosa foi liofilizada, sendo designada de peptona e submetida à análise eletroforética que apresentou maior concentração de proteínas na faixa de 47-60 kDa. A atividade antioxidante foi avaliada em diferentes concentrações utilizando ensaios in vitro como o método do radical 2,2-azinobis-(3-etilbenzotiazoline-6-ácido sulfônico) (ABTS) e 1,1-difenil-2-picrilhidrazil (DPPH), sendo que, em ambos, o aumento da atividade antioxidante acompanhou a concentração. Com destaque para o extrato 15 mg/ml que propiciou 46,23% de inibição do radical ABTS, e 83,22% em DPPH. Em relação ao teste de efetividade, foram comparadas peptonas comerciais e a peptona da água residual liofilizada, sendo avaliada a curva de crescimento pela densidade óptica, produção de biomassa e detecção por plaqueamento da Escherichia coli e Staphylococcus aureus. A performance obtida nas peptonas da água residual foram superiores às comerciais, evidenciando o vantajoso reuso desse efluente como coproduto destinado ao cultivo de microrganismos. O desempenho do peptídeo residual permite que se recomende o seu uso por parte das empresas que buscam a ecoeficiência / The wastewater of minced tilapia (Oreochromis niloticus) processing is discarded without any use, constituting a effluent of potential impact on the environment. The aim of this study was to evaluate this effluent, characterize its protein fraction, verify its antioxidant potential and its efficiency as a culture medium for microbial growth. Mechanically separated meat (CMS) tilapia was submitted to clarification operation in distilled water at 10°C in a 1:3 ratio, a process that constitutes homogenizing for 3 minutes, rest for 3 minutes, and the minced packed and compressed in a sterilized cotton fabric for drainage of wastewater. The effluent generated by the minced washing step showed 8854.5 mgO2 / L of COD and 4656.88 mgO2 / L BOD, values considered among high quality standards due to the high content of organic matter. The effluent was subjected to centrifugation and the aqueous fraction was lyophilized, and designated peptone and subjected to electrophoresis analysis showed a higher concentration of proteins in the 47-60 kDa range. The antioxidant activity was evaluated at different concentrations using in vitro assays such as radical method 2,2-azinobis- (3-sulphonic acid 6-etilbenzotiazoline) (ABTS), and 1,1-diphenyl-2-picrylhydrazyl (DPPH), wherein, in both the increased antioxidant activity followed the concentration. Especially the extract 15 mg / ml which provided 46.23% inhibition of ABTS radical, and 83.22% in DPPH. Regarding the effectiveness test, they were compared to commercial peptones and peptone lyophilized wastewater, assessing growth curves by optical density biomass production by plating and detection of Escherichia coli and Staphylococcus aureus. The performance achieved in peptones wastewater were higher than commercial, showing the beneficial reuse of the effluent as a co-product intended for microorganisms cultivation. The performance of the residual peptide allows recommending its use by businesses seeking eco-efficiency

Page generated in 0.0686 seconds