• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 54
  • 3
  • 1
  • 1
  • Tagged with
  • 60
  • 60
  • 47
  • 32
  • 30
  • 29
  • 27
  • 26
  • 20
  • 17
  • 14
  • 11
  • 11
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Comportamento de reator UASB sem separador trifásico no tratamento de esgoto sanitário. / Behavior of UASB reactor without three-phase separator in the sewage treatment.

Bruno Martins de Camargo 05 September 2016 (has links)
O objetivo do presente trabalho foi a avaliação das características operacionais de um reator UASB sem o dispositivo de coleta de gás (separador trifásico) e sem o anteparo retentor de escuma posicionado próximo à canaleta de coleta do efluente. A motivação para esta pesquisa foi o interesse manifestado pelas companhias de saneamento em aplicar esta simplificação, que poderá implicar em economia na implantação dos reatores e praticamente na eliminação da necessidade de remoção de escuma. Utilizou-se um reator UASB com tais simplificações com volume útil de 24,5 m3 e estabeleceu-se uma estratégia operacional com aumento gradual da vazão de alimentação, compondo quatro fases de operação, com tempos de retenção hidráulica respectivamente de 16, 12, 10 e 8 horas. As vazões foram mantidas constantes em cada fase, com exceção da última, em que se impôs dois picos de vazão ao longo dia. O reator manteve-se operando com eficiências médias de remoção de DQO total, respectivamente, de 65,9%, 60,3%, 48,7% e 15,0%. De modo geral, pode-se afirmar que o reator piloto não apresentou o desempenho esperado, em termos de remoção de matéria orgânica, para TDH de 8 horas. Quanto ao perfil de sólidos no manto de lodo, nas duas primeiras etapas (TDH de 16 e 12 horas), o teor de sólidos daquele foi elevado, mas reduziu-se drasticamente a partir da etapa com TDH de 10 horas. Na última etapa, o comportamento da manta de lodo foi pouco previsível, observando-se progressivo arraste de sólidos do reator. Em função da grande perda de sólidos, acredita-se que o artifício empregado possa ser utilizado com melhor desempenho com a implantação de um decantador a jusante do reator ou mediante a aplicação de um pós-tratamento que garanta a recuperação dos sólidos perdidos (por exemplo, lodos ativados). Outra alternativa é a própria substituição do UASB pelo decantador primário antes de um pós-tratamento aeróbio. / The objective of this study was to evaluate the operational characteristics of a UASB reactor without the gas collection device (three phase separator) and without the scum retainer screen positioned near the effluent collection channel. The motivation for this research was the interest shown by sanitation companies to apply this simplification, which can result in savings in the implementation of the reactors and practically in eliminating the need of scum removal. An UASB reactor was used with such simplifications with a volume of 24.5 m3 and an operational strategy was established with gradual increase of the feed flow, consisting of four operating phases, with hydraulic retention times, respectively, of 16, 12, 10 and 8 hours. The flows were kept constants at each operating phase, except the last, which was imposed two peak flows throughout the day. The reactor was kept operating with efficiency of COD removal, respectively, of 65.9%, 60.3%, 48.7% and 15,0%. Generally, the pilot reactor had not the expected performance in removal of organic matter, with hydraulic retention time of 8 hours. In the first two fases (HDT of 16 and 12 hours), solid\'s content in sludge blanket was high, but had reduced significantly from the second fase, with 10 hours of HDT. In the last fase, the sludge blanket behavior was bit predictable, with progressive drag of solids from reactor. Because of high solids loss, it is believed that the applied device can be used with better performance with the implantation of a settler after the reactor or a post-treatment that ensures the lost solids recovery (for example, activated sludge). Another alternative is the replacement of UASB by the primary clarifier before aerobic post-treatment.
42

Desempenho de reatores UASB expostos a choques de carga hidráulica e diluição de matéria orgânica devidos a eventos de chuva

Salazar Peláez, Mónica Liliana January 2007 (has links)
Os sistemas de esgotos urbanos são classificados em separador absoluto, separador parcial e unitário, conforme o grau de separação que existe no recolhimento dos esgotos sanitários e das águas de drenagem pluviais. Embora a diretriz das cidades brasileiras seja a adoção do sistema separador, na prática ocorre uma importante contribuição das águas de chuvas nas vazões afluentes às estações de tratamento de esgotos como produto das interconexões existentes, clandestinas ou não, entre as redes de esgotos sanitários e pluviais. Esta pesquisa investigou os impactos causados pelos choques de carga orgânica e hidráulica provocados pela contribuição das águas pluviais no desempenho de reatores UASB e seu tempo de recuperação depois de sofrer estes choques. Três reatores de acrílico de 17 litros foram construídos no Laboratório de Saneamento Ambiental do IPH. Os reatores trataram esgoto sintético simulando a concentração de DQO de esgotos domésticos a uma temperatura de 30 ± 2 °C. Um dos reatores serviu de controle enquanto os outros dois receberam choques de carga hidráulica (aumento de vazão) e diluição de matéria orgânica, simultaneamente. A operação dos reatores foi dividida em três fases: 1°) aclimatação, 2°) choques individuais de carga hidráulica e diluição de matéria orgânica 3°) simulação de uma temporada de chuva. Os choques tiveram um efeito deletério na qualidade do efluente, ocasionando quedas na eficiência de remoção de DQO total de até quase 600% e de 200% na eficiência de remoção de DQO dissolvida nos choques mais severos. Também constatou-se perda de parte da biomassa presente nos reatores devido ao aumento excessivo na velocidade ascensional do fluxo. Esta perda tornou-se menor com o tempo devido à pressão de seleção exercida pelos sucessivos choques. O pH dentro dos reatores manteve-se sempre perto da faixa neutra, porém apresentou-se um consumo de alcalinidade que se prolongou por até três vezes o tempo de detenção hidráulica após o início dos choques, devido provavelmente ao aumento na concentração de ácidos graxos voláteis no efluente. A produção de biogás também diminuiu como conseqüência da diluição da carga orgânica afluente. Os efeitos e o tempo de recuperação após os choques dependeram da sua duração e magnitude, sendo que os choques mais severos (menor concentração de matéria orgânica afluente e TDH) causaram maior deterioração na qualidade do efluente e requereram maior tempo de recuperação.Já no que diz respeito às características físico-químicas e biológicas do lodo, verificou-se que os choques causaram diminuição no tamanho médio dos grânulos do lodo e na sua velocidade de sedimentação, provavelmente devido ao aumento das forças abrasivas v provocado pelo incremento na velocidade ascensional do fluxo. De igual modo, a atividade metanogênica específica também apresentou quedas devidas, provavelmente, à diluição da carga orgânica afluente e à diminuição do tamanho das partículas do lodo. / Sewerage systems are classified as separate, partially separated, or combined, according to the degree of separation that exists in the collection of municipal wastewater and stormwater runoff. Although the official policy of brazilian cities is for adoption of the separate system, the actual scenario shows that there are significant contributions of stormwater to the flows that are transported to the wastewater treatment plants, partly because of the inappropriate interconnections that exist between the systems. This research investigated the impacts that organic and hydraulic shock loads brought by stormwater contributions have on the efficiency of UASB reactors, as well as the recovery time after the ending of the shocks. Three 17-liters acrylic reactors were built in the Environmental Technology Laboratory at IPH. The reactors were fed with synthetic wastewater prepared to resemble the organic content of wastewater. All reactors were operated at a temperature of 30 ± 2ºC. One of the reactors was used as control while the other two received hydraulic shocks with organic matter dilution, simultaneously. Reactor’s operation was divided in three phases: 1º) star-up, 2º) single organic and hydraulic shocks, and 3º) rain season simulation, with multiple shocks.Shocks have a deleterious effect on the reactor effluent quality. In the most severe cases, drops in removal efficiencies reached up to 200% and 600% for dissolved and total DQO, respectively. Reactor biomass washout occurred due to the increasing upflow velocity. This loss was dampened by the selective pressure exerted by successive shocks. pH in the reactors remained in the neutral range, although alkalinity was consumed for as long as three detention times, probably due to an increase in the concentration of volatile fatty acids in the liquid. Dilution also caused a decrease in biogas production. Recovery time depended on the duration and intensity of the shock, with more severe shocks demanding more time for recovery. The impacts of the shocks on the treatment efficiency depended on duration, organic dilution rate and flowrate increase. Longer shocks, with higher flowrates and dilution rate resulted in the worst conditions for the reactor. Shocks loads caused a decrease in the mean size of the sludge granule, as well as in their sedimentation velocities, probably because of an increase in the abrasive forces acting on the granules brought by the upflow velocity. The specific methanogenic activity also decreased with higher dilution and smaller sized sludge granules.
43

Coagulação, floculação e flotação do efluente de reatores anaeróbios, tratando esgoto sanitário, com aplicação de diferentes dosagens de coagulante em função da variação da turbidez do esgoto afluente ao longo do dia / Coagulation, flocculation and flotation of anaerobic reactor effluents, treating sewage with the employment of different amounts of coagulant, according to the variation in sewage turbidity throughout the day

Gustavo Carneiro Ariano 11 September 2009 (has links)
Este trabalho avaliou a técnica de dosagem variável de coagulante em função da variação da turbidez do esgoto afluente a sistema de pós-tratamento por flotação do efluente de reatores UASB, localizado em Campinas, SP. Utilizou-se equipamento do tipo Flotateste para a flotação em escala de laboratório, sendo fixados os parâmetros: Tmr = 15 s; Gmr = 800 \'S POT.-1\'; Tfloc = 20 min; Gfloc = 90 \'S POT.-1\'; Psat = 5,00 Bar. Foram estudadas quatro velocidades de flotação (Vf), entre 8 à 20 cm/min. Na fase 1 da pesquisa estudou-se os coagulantes \'AL IND.2\'(\'SO IND.4\')\'IND.3\', PAC e \'FE\'Cl IND.3\', sendo determinadas as melhores dosagens para o horário das 12:00 horas. Posteriormente, na segunda fase, foram fixadas as melhores dosagens de cada coagulante e associada dosagens variadas de polímeros catiônico, aniônico e não iônico. Em seguida, na fase 3, foi realizada avaliação temporal, com ensaios realizados em seis diferentes horários do dia, estabelecendo uma razão entre a variação da turbidez afluente com a dosagem de coagulante. Finalmente, na quarta fase, foram aplicados quatro cenários de dosagens em doze horários diferentes ao longo de 24 horas. Para fase 1, verificou-se remoção de SST, DQO e fósforo para as dosagens de \'AL IND.2\'(\'SO IND.4\')\'IND.3\' (11,77mg \'AL IND.2\'O IND.3\'/L), 76,5%; 67,6% e 63,9%; PAC (8,45 mg \'AL IND.2\'O IND.3\'/L), 62,5%; 75,0% e 82,7%; e \'FE\'CL IND.3\' (24,38 mg\'FE\'/L), 60,0%; 55,9% e 90,3%, respectivamente, para Vf = 16 cm/min. Na fase 2, determinou-se como melhor polímero, para ambos coagulantes, o polímero catiônico (PC), sendo associado às melhores dosagens definidas na fase1. Desta maneira na fase 2 verificou-se remoção de SST, DQO e fósforo para as dosagens associadas de \'AL IND.2\'(\'SO IND.4\')\'IND.3\' + PC (11,77 mg\'AL IND.2\'O IND.3\'/L + 1,00 mg PC/L), 94,4%, 88,6% e 70,4%; PAC + PC (8,45 mg\'AL IND.2\'O IND.3\'/L + 1,00 mg PC/L), 94,7%, 62,3% e 88,8%; e \'FE\'CL IND.3\' + PC (24,38 mg\'FE\'/L + 1,00 mg PC/L), 77,3%, 61,6% e 91,6%, respectivamente. O cloreto férrico foi escolhido para ser utilizado nas fases seguintes devido a capacidade de precipitação de sulfeto o qual atingiu concentrações de até 15 mg/L no efluente anaeróbio. Em adição, foram fixadas as dosagens de polímero catiônico em 1,00 mg/L. Assim, para fase 3, a aplicação de dosagem variada entre 12,07 a 25,51 mg\'FE\'/L, para seis diferentes horários resultou em DQO < 50 mg/L e Fósforo < 0,50 mg/L para Vf = 16 cm/min. A aplicação de razão entre a dosagem de \'FE POT.+3\' e a turbidez afluente (RDmT) de 0,463 mg\'FE POT.+3\'/L.UNT (para turbidez < 50 UNT) e 0,244 mg\'FE POT.+3\'/L.UNT (para turbidez >50 UNT) na fase 4, garantiu para todas as velocidades de flotação estudadas turbidez < 15 UNT em 100% dos ensaios. Em adição, ao se realizar correlação entre a concentração de SST no efluente da FAD e a turbidez, chegou-se a conclusão de que este cenário atingiu remoção de lodo próxima a dosagem de \'FE\'CL IND.3\' máxima definidas na fase 3 (74 mg\'FE\'CL IND.3\'/L), com economia de 27,8% no consumo do coagulante. / This study evaluated the variable coagulant dosage technique according to the variation in turbidity of the influent sewage of the post-treatment flotation system of the UASB reactor effluents, located in Campinas, SP. Laboratory scale flotation equipment was used, with fixed parameters: Tmr = 15 s; Gmr = 800 \'S POT.-1\'; Tfloc = 20 min; Gfloc = 90 \'S POT.-1\'; Psat = 5,00 Bar. Four flotation velocities (Vf), between 8 a 20 cm/min, were studied. Phase 1 of the research studied the coagulants \'AL IND.2\'(\'SO IND.4\')\'IND.3\', PAC e \'FE\'CL IND.3\', being determined the best dosages for 12:00 pm. In phase 2 the best dosages of each coagulant were fixed and the associated cationic, anionic and nonionic polymer dosages were varied. In phase 3 experiments were taken at six different periods of the day, establishing a ratio between the variation in influent turbidity and coagulant dosage. In the fourth phase, four different dosage scenarios were applied at twelve different periods during a 24 hour day, to verify the best dosage scenario. In phase 1, the removal of TSS, COD and phosphorus was verified to the dosages of \'AL IND.2\'(\'SO IND.4\')\'IND.3\' (11,77 mg\'AL IND.2\'O IND.3\'/L), 76,5%; 67,6% and 63,9%; PAC (8,45 mg\'AL IND.2\'O IND.3\'/L), 62,5%; 75,0% and 82,7%; and \'FE\'CL IND.3\' (24,38 mg\'FE POT.+3\'/L), 60,0%; 55,9% e 90,3%, respectively, for Vf = 16 cm/min. In phase 2 the cationic polymer (PC) was determined to be the best polymer for both coagulants, when applied to the best dosages determined in phase 1. This way, in phase 2 the removal of TSS, COD and phosphorus was verified to the associated dosages of \'AL IND.2\'(\'SO IND.4\')\'IND.3\' + PC (11,77 mg\'AL IND.2\'O IND.3\'/L + 1,00 mg PC/L), 94,4%, 88,6% and 70,4%; PAC + PC (8,45 mg\'AL IND.2\'O IND.3\'/L + 1,00 mg PC/L), 94,7%, 62,3% and 88,8%; and \'FE\'CL IND.3\' + PC (24,38 mg\'FE POT.+3\'/L + 1,00 mg PC/L), 77,3%, 61,6% e 91,6%, respectively. Ferric chloride was chosen in the following phases due to its sulfide precipitation ability, reaching concentrations of up to 15 mg/L in the anaerobic effluent. In addition, the cationic polymer dosages were fixed to 1,00 mg/L. Thus, in phase 3, the dosage, varying between 12,07 to 25,51 mg\'FE POT.+3\'/L, applied to six different periods resulted, to Vf = 16 cm/min, in COD < 50 mg/L and phosphorus < 0,50 mg/L. The ratio between the dosage of \'FE POT.+3\' and the influent turbidity (RDmT) of 0,463 mg\'FE POT.+3\'/L.UNT (for turbidities < 50 NTU) and 0,244 mg\'FE POT.+3\'/L.UNT (for turbidities \'< OU =\' 50 NTU) when applied in phase 4, ensured, in 100% of the experiments, turbidity < 15 NTU for the studied flotation velocities. In addition, when correlating the concentration of TSS in FAD effluents with the turbidity, the conclusion was that this scenario reached a sludge removal close to that obtained by the maximum \'FE\'CL IND.3\' dosage defined in phase 3 (74 mg\'FE\'CL IND.3\'/L), with an economy of 27,8% in coagulant consumption.
44

Reator anaeróbio híbrido para tratamento de esgoto sanitário / Hybrid anaerobic reactor for domestic sewage treatment

Fernando Hermes Passig 11 March 2005 (has links)
Este trabalho de investigação refere-se ao uso do reator anaeróbio híbrido para tratamento de esgoto sanitário, com configuração baseada no reator anaeróbio de manta de lodo (UASB) com inclusão de: meio suporte sobre as calhas de coleta de gás (denominado reator anaeróbio híbrido - UAHB) e, também, meio suporte na zona de reação (denominado reator anaeróbio híbrido modificado - UAHBmod). Para o desenvolvimento desta pesquisa, no Campus I da USP de São Carlos-SP foram construídos dois reatores experimentais de 18,8 m3 cada: um reator UASB, com função de controle, e um reator UAHB. Primeiramente os reatores foram operados por período de 200 dias, com tempo de detenção hidráulica (TDH) de 6 h. Após serem inoculados, com 80 dias de operação, os reatores atingiram o estado de equilíbrio dinâmico aparente, com geração de alcalinidade, baixa concentração de ácidos voláteis e eficiência de remoção média de DQO, de 84% e 85% e de DBO de 87% e 91%, respectivamente para o UASB e o UAHB. Após esse período, os reatores foram submetidos a aumento da velocidade ascensional (Vasc) (mediante recirculação do efluente) de 0,78 m.h-1; 1,17 m.h-1; 1,56 m.h-1 e de 1,96 m.h-1. O UAHB mostrou ser menos susceptível ao aumento da Vasc do que o UASB. Além da análise da operação dos reatores, foram realizados os ensaios hidrodinâmicos e avaliada a estrutura da comunidade microbiana, por microscopia ótica, epifluorescência e pela técnica do DGGE. Após esse período preliminar, os reatores UAHB e UAHBmod, operados com TDH de 6h e Vasc de 0,78 m.h-1, atingiram o estado de equilíbrio dinâmico aparente, com geração de alcalinidade, baixa concentração de ácidos voláteis e eficiência de remoção média da matéria orgânica, de 71% e 76% em DQO, e de 72% e 87% em DBO, respectivamente para o UAHB e UAHBmod. Após este período, o reator UAHBmod, submetido a Vasc de 1,56 m.h-1, promoveu remoção de 74% de DQO, e de 87% de DBO. / This research refers to the use of a hybrid anaerobic reactor (UAHB) for domestic wastewater treatment. The configuration of this reactor is based on a sludge bed anaerobic reactor (UASB); in the first instance, a media support above the gas collection apparatus (also known as hybrid anaerobic reactor) was provided and later, a media support on the reaction zone (also known as hybrid modified anaerobic reactor - UAHBmod) was provided. Two reactors, with a volume of 18.8 m3, each, were built for this research at Campus I, USP in São Carlos - SP-Brazil. One UASB reactor acted as a control, and the other as a UAHB reactor. In the preliminary essays, the reactors were operated with 6h of hydraulic detention time (HDT) for 200 days. After inoculation, the reactors attained the apparent dynamic equilibrium state after 80 days of operation, with alkalinity generation, low volatile acids concentration and mean organic matter removal of 84% and 85% in terms of COD, and 87% and 91% in terms of BOD, for UASB and UAHB reactors, respectively. After this period, the reactors were submitted to an increasing in up velocity (Vup) of 0.78 m.h-1; 1.17 m.h-1; 1.56 m.h-1 and 1.96 m.h-1. The UAHB reactor showed lesser susceptibility for Vup increase than the UASB reactor. Hydrodynamic tests were also done on the reactors, in addition to routine operational analysis. The structure of the microbial community was evaluated by optical and epifluorescence microscopy, and the DGGE technique. After this step, the UAHB and the UAHBmod reactors were operated out 6h of HDT and Vup of 0.78 m.h-1. The reactors attained the apparent dynamic equilibrium state with alkalinity generation, low volatile acids concentration and mean organic matter removal of 71% and 76% in terms of COD, and 72% and 87% in terms of BOD for the UASB and UAHBmod reactors, respectively. After this period, the UAHBmod reactor was subjected to a Vup of 1.56 m.h-1 and achieved removal efficiencies of 74% COD and 87% BOD.
45

Ocorrência e remoção dos protozoários patogênicos Giardia spp. e Cryptosporidium spp. em sistemas de tratamento de esgoto sanitário / Occurrence and removal of patogenic protozoa Giardia spp. and Cryptosporidium spp. in sanitary sewage treatment systems

Priscila Ribeiro dos Santos 03 July 2015 (has links)
O propósito do presente estudo foi investigar e monitorar a remoção de cistos de Giardia spp. e oocistos de Cryptosporidium spp. por diferentes processos de uma estação de tratamento de esgoto (ETE) em escala plena, composta basicamente por tratamento preliminar, reator UASB e flotador por ar dissolvido, e verificar a ocorrência desses protozoários no lodo do reator UASB e do flotador. Além disso, avaliou-se a remoção desses parasitos pelo processo de flotação por ar dissolvido em escala de bancada (equipamento Flotateste). Analisou-se a qualidade das amostras a partir de variáveis físicas e químicas, e pela detecção de microrganismos indicadores - E. coli, coliformes totais e Clostridium perfringens. Os métodos de detecção de protozoários se basearam nas etapas de concentração (tripla centrifugação ou filtração em membrana seguida de tripla centrifugação); purificação por separação imunomagnética (IMS); detecção por reação de imunofluorescência direta (RID). As recuperações de cistos variaram de 32,6 a 67,0 &#37; dependendo do método adotado, já para os oocistos as recuperações estiveram na faixa de 5,6 a 12,0 &#37;. Na ETE-Monjolinho foram detectadas significativas quantidades de cistos de Giardia spp. em 100% das amostras de esgoto analisadas, com concentração média de 1,89 x 104 e 2,35 x 102 cistos.L-1 no esgoto bruto e tratado, respectivamente. Já os oocistos de Cryptosporidium spp. foram detectados em 39,0 &#37; das amostras de esgoto, com concentração média de 1,35 x 102 oocistos.L-1 no esgoto bruto e 5,87 oocistos.L-1 em esgoto tratado (após flotador). A remoção global da ETE para remoção de Giardia spp. foi em média 2,03 log. O lodo do reator UASB e lodo do flotador apresentaram altas quantidade de (oo)cistos, constatando-se a tendência desses sistemas em concentrar os (oo)cistos por seus processos físicos. Algumas correlações significativas foram encontradas, como correlação entre a concentração de cistos no lodo e a variável sólidos totais, a concentração de cistos no esgoto bruto e as variáveis cor aparente, DQO total e particulada, e a concentração de cistos no efluente UASB e o microrganismo Clostridium perfringens. Diferentemente do flotador em escala plena, o processo do flotação por ar dissolvido em escala de bancada alcançou elevadas remoções médias de cistos de Giardia spp., entre 2,5 e 2,7 log nas diferentes condições de floculação estudadas. / The aim of this study was to investigate and monitor the removal of Giardia spp. cysts and Cryptosporidium spp. oocysts through different processes of a sewage treatment plant (STP) in full scale, consisted of preliminary treatment, UASB reactor, dissolved air flotator, and to verify the occurrence of the protozoa in the sludge derived from UASB reactor and flotator. Besides that, it was evaluated the removal of these parasites through the dissolved air flotation process in bench scale. It was analyzed the quality of the samples through physical and chemical variables, and detection of indicator microorganisms &#8211; E. coli, total coliforms and Clostridium perfringens. The detection methods of protozoa were based on steps of concentration (triple concentration or membrane filtration followed by triple concentration); purification by immunomagnetic separation (IMS); immunofluorescence assay (IFA). The recovery of cysts ranged from 32,6 to 67,0 &#37; according to the adopted method, while the recovery for the oocysts ranged from 5,6 to 12,0 &#37;. It was detected significant quantities of Giardia spp. cysts in 100 &#37; of the analyzed sewage samples at the STP-Monjolinho, with mean concentration of 1,89 x 104 e 2,35 x 102 cysts.L-1in raw sewage and treated sewage, respectively. The oocysts of Cryptosporidium spp. were detected in 39,0 &#37; of the sewage samples, with mean concentration of 1,35 x 102 oocysts.L-1 in raw sewage and 5,87 oocysts.L-1 in treated sewage (after flotator). The overall removal for Giardia spp. was on average of 2,03 log. The sludge from UASB reactor and flotator presented high quantities of (oo)cysts, implying the tendency of these systems to concentrate (oo)cysts through its physical processes. Some correlations were obtained, such as correlation between the concentration of cysts in the sludge and total solids, the concentration of cysts in the raw sewage and apparent color, total and particulate COD (chemical oxygen demand), and the concentration of cysts in the UASB effluent and the microorganism Clostridium perfringens. Unlike the full flotator, the dissolved air flotation in bench scale reached significant mean removal of Giardia spp. cysts, between 2,5 and 2,7 log according to the different flocculation conditions.
46

Resposta dinâmica dos reatores UASB (Upflow Anaerobic Sludge Blanket) submetidos a cargas senoidais / not available

Kátia Bakker Batista 16 November 2000 (has links)
Esta pesquisa consistiu na verificação do comportamento do reator UASB de bancada (volume igual a 10,5 litros), quando submetido a variações senoidais de vazão afluente, comparando-se com a eficiência no seu funcionamento com vazão constante, através de análises de amostras de afluentes e efluentes. O reator UASB utilizado foi montado no Laboratório de Processos Biológicos da EESC-USP dentro de uma câmara com temperatura constante de 30 ± 3°C, e alimentado com esgoto sintético, com DQO de 500 mg/l, 750 mg/l e 1000 mg/l. O reator foi inoculado em abril de 1999, com 3,5 litros de lodo anaeróbio proveniente de um reator compartimentado, também situado na EESC-USP. Devido à dificuldade de atingir um valor esperado para a eficiência de remoção de Matéria orgânica, foi dada nova partida no reator, em julho de 1999, desta vez com lodo proveniente de outro UASB. Após a segunda partida, o reator operou com vazão constante e DQO afluente em torno de 500 mg/l até setembro de 1999, com média de remoção de DQO bruta de 75% no período, passando-se, então, à fase de variação senoidal de vazão de forma que o máximo e o mínimo fossem de ±30%, ±45% e ±60% da vazão média. Para este regime, obteve-se 80% de eficiência média de remoção de DQO bruta. Os valores de pH, alcalinidade e ácidos voláteis foram praticamente constantes durante a operação. Os perfis de remoção de DQO ao longo do dia mostraram uma pequena queda na eficiência do reator, aproximadamente 1,5 vezes o tempo de detenção hidráulica médio (8 horas), após os máximos de vazão para o regime de variação de vazão de ±30% e ±45% e 2,5 vezes o tempo de detenção hidráulica médio, para variação e ±60%. O mesmo experimento foi repetido para DQO afluente de 1000 mg/l e obteve-se, em média, eficiências de 65% de remoção de DQO. / This research consisted in the UASB reactor performance verification when it was submitted to sine-based variations of loading rate, in comparison to its normal operation. The UASB reactor used was set up at the Biological Process Laboratory of EESC-USP, inside a camera with temperature of 30°C ± 3°C. It was fed with synthetic sewage (COD = 500, 750 and 1000 mg/l). After start-up, the reactor was operated with constant loading rate (COD = 500 mg/l) until September 1999. The organic matter removal average in this period was 75%. Then, it was initiated the phase of sine-based variation loading rate (±30%, ±45% and ±60%). In this regime, it was obtained a medium gross COD removal efficiency of 80%. The pH values, alkalinity and volatile acids were practically constant during the operation. The COD removal profiles during the day showed a subtle fall in the reactor efficiency after 1.5 times the medium hydraulic detection time, for the loading rate variation of ±30% and ±45%. For ±60% variation, the answer time was approximately 2.5 times the medium hydraulic detection time. The efficiency of gross COD removal stay however over 78,53% until the experiment 9, witch showed that the reactor can stand the loading rate variations. The efficiency of filtered COD removal decreased on the second experiment, came back to the initial values and decreased again. The values of variation didn\'t surpass 6,6% for gross COD and 8,43% for filtered COD.
47

Remoção de cistos de Giardia spp. e de Cryptosporidium spp. em sistema de tratamento de esgoto sanitário: quantificação em fases líquida e sólida / Removal of Giardia spp. cysts and Cryptosporidium spp. oocists in wastewater treatment systems: quantification in liquid and solid fases

Eraldo Kobayashi dos Santos 25 September 2015 (has links)
No atual cenário de saneamento, há uma escassez de estudos na temática de retenção de microrganismos patogênicos em estações de tratamento de esgotos, onde os principais tratamentos se baseiam na remoção de parâmetros físico-químicos. Uma abordagem mais ampla na remoção destes microrganismos em estações de tratamento e sua quantificação no lodo retido é um passo importante para o aumento do debate acerca da eficiência dos atuais tratamentos utilizados na retenção de patógenos, diminuindo assim a contaminação de corpos d\'água com posteriores problemáticas no âmbito de saúde pública. Desta forma, a proposta do projeto foi avaliar e quantificar a remoção de cistos de Giardia spp., oocistos de Cryptosporidium spp. e Escherichia Coli em sistema de tratamento de esgoto sanitário constituído de tratamento anaeróbio (reator UASB), utilizando dois valores de TDH - 8 horas (Etapa 1) e 12 horas (Etapa 2) - seguido de tratamento em sistema de lodo ativado. O projeto utilizou uma estação de tratamento piloto junto a estação de tratamento da USP São Carlos. Para análises de E. coli e coliformes totais foi utilizada a técnica de pour plate e para detecção de cistos e oocistos de Giardia spp. e Cryptosporidium spp., a técnica de separação imunomagnética (IMS) e técnica de Reação de Imunoflorescência Direta (RID) foi escolhida como método de detecção e quantificação. Para a remoção no reator UASB, a variação de TDH indicou influência na remoção de parâmetros físico-químicos e na retenção de microrganismos, sendo que a utilização de TDH de 12 horas obteve remoções de 0,21 log para cistos Giardia spp. e 0,48 log para oocistos de Cryptosporidium spp. Para o Sistema de Lodo ativado, as remoções foram de 0,48 log e 0,15 para ambos os microrganismos, respectivamente, não havendo influência significativa na retenção com a mudança de TDH do reator UASB. Nas análises em fase sólida, foram observados valores altos de contaminação no lodo, tanto para Giardia spp., quanto para Cryptosporidium spp., onde a viabilidade dos (oo)cistos detectados estiveram na faixa de 30% a 99% nas amostras analisadas. / Currently, the field of sanitation faces a lack of studies on retention of pathogenic microorganisms in wastewater treatment plants, where main treatments are based on the removal of physical and chemical parameters. A broader approach to the removal of pathogens in wastewater treatment systems and their quantification in retained sludge is an important step to increase the debate around the efficiency of prevailing treatments used to retain those microorganisms and to consequently reduce the contamination of water bodies. The present study was conducted to assess and quantify the removal of Giardia spp. cysts, Cryptosporidium spp. oocysts and E. coli in wastewater treatment systems. For the purpose of this research, the treatment consisted of a UASB reactor using two values of hydraulic retention time (HRT) - 8 hours (phase 1) and 12 hours (phase 2) - followed by an activated sludge system. The project was staged in a pilot wastewater treatment plant coupled to USP Sao Carlos\' wastewater treatment system. Pour plate technique was used for analysis of E.coli and total coliforms. IMS was used to detect cysts and oocysts of Giardia spp. and Cryptosporidium spp. DFA (direct immunofluorescence assay) method was chosen to detection and quantification. HRT variation for removal in UASB reactor indicated influence in removal of physical and chemical parameters and in retention of microorganisms. The 12 hours use of HRT obtained removals of 0.21 log for Giardia cysts and 0.48 log for Cryptosporidium oocysts. Activated sludge removals presented 0.48 log and 0.15 log respectively, without significative influence in retention with the HRT\'s change in UASB reactor. High values of contamination were observed during solid-phase analysis in activated sludge, both for Giardia and Cryptosporidium. Here, viability of the (oo)cysts detected was around 30% up to 99% of the analyzed samples.
48

Minimização de afluentes e avaliação de sistema biológico de tratamento de águas residuárias em uma indústria de conservas vegetais / Effluent minimization and evaluation of wastewater biologic system treatment in a vegetable-cannery industry

Huber, Charles Soares 10 December 2007 (has links)
Made available in DSpace on 2014-08-20T13:32:51Z (GMT). No. of bitstreams: 1 dissertacao_charles_huber.pdf: 1046471 bytes, checksum: a81eb3b445f28a007ba73c7b94476592 (MD5) Previous issue date: 2007-12-10 / The addition a chemical surfactant in the sodium hydroxide solution was evaluated in the peach peeling process. The results were compared to the traditional process, without chemical addition. It could be observed reduction from 57.14% in the sodium hydroxide consumption, 49.18% in wastewater generation of the fruit washing process and 42.81%, 16.02%, 45.45%, 24.16% and 31.82%, in the loads of chemical oxygen demand (COD), biochemical oxygen demand (BOD), total Kjeldahl nitrogen (TKN), total suspended solids (TSS) and the settleable solids (SS), respectively. The fruit-cannery wastewaters must be treated. There are several processes that can be used for the removal of materials and chemicals that can degrade the environment. An upflow anaerobic sludge blanket (UASB) of a cannery industry (fruits and vegetables) was evaluated. The system was assessed for 712 days and the efficiency of total DQO removal was evaluated. The start-up began with a mean organic loading rate (OLR) of 0.40kgDQO.m-3.d-1, and achieved a maximum OLR of 5.29kgDQO.m-3.d-1 in 307 days. The mean removal of total DQO was 86.87%. This study showed that even with the seasonality of production, the UASB reactor is a good alternative for the secondary treatment of fruit-cannery industry / Avaliou-se a adição de um surfactante químico à solução de hidróxido de sódio, utilizada no processo de descasque químico do pêssego. Os resultados obtidos foram comparados com o do processo tradicional, sem a adição desta substância. Observou-se reduções de 57,14% no consumo de hidróxido de sódio, 49,18% na geração de efluente líquido, no processo de lavagem da fruta e 42,81%, 16,02 %, 45,45%, 24,16% e 31,82%, nas cargas da demanda química de oxigênio (DQO), demanda bioquímica de oxigênio (DBO), nitrogênio total Kjeldahl (NTK), sólidos suspensos totais (SST) e dos sólidos sedimentáveis (SS), respectivamente. As águas residuárias originadas no processo de industrialização da fruta devem ser tratadas em uma estação de tratamento de efluentes. Existem diversos processos que podem ser utilizados para a remoção dos materiais e substâncias potencialmente prejudiciais ao meio ambiente. Monitorou-se a partida e a operação de um reator anaeróbio de fluxo ascendente (UASB) tratando efluentes de uma indústria de conservas de frutas e vegetais. O sistema foi monitorado por 712 dias e avaliou-se a eficiência da remoção de demanda química de oxigênio (DQO) total. O início da operação do reator foi com uma carga orgânica volumétrica (COV) aplicada de 0,40kgDQO.m-3.d-1, atingindo-se uma COV máxima de 5,29kgDQO.m-3.d-1 em 307 dias. A remoção de DQO total foi de 86,87%. Este estudo mostrou que mesmo com a sazonalidade de produção, os reatores UASB são uma boa alternativa de tratamento secundário para a indústria conserveira
49

Avaliação da remoção de Giardia spp. e Cryptosporidium spp. em processos de tratamento de esgoto sanitário / Assessment of removal of Giardia spp. and Cryptosporidium spp. from wastewater treatment processes

Medeiros, Raphael Corrêa 27 September 2013 (has links)
Este trabalho teve o intuito de avaliar a eficiência de remoção de protozoários patogênicos - Giardia spp. e Cryptosporidium spp. - em processos de tratamento de esgoto sanitário por reator UASB, lodos ativados, filtro lento em areia e diferentes desinfetantes. A recuperação de cistos de Giardia e de oocistos de Cryptosporidium, realizada por diferentes metodologias e utilizando ColorSeed®, foi de, respectivamente, 85 e 20% em esgoto bruto, e 62,5 e 17,5% em efluente tratado, quando foi utilizado o método de tripla centrifugação. Cistos de Giardia foram encontrados em 100% as amostras de esgoto pesquisadas, com média de 1,5 x 104 cistos por litro e oocistos de Cryptosporidium em 31,4% com média 3,1 x 10² oocistos por litro, em esgoto bruto. No tratamento biológico por reator UASB seguido de Lodos Ativados, a remoção de cisto de Giardia e esporos de Clostridium perfringens foram estatisticamente menores que as remoções de E. coli e coliformes totais. Não foram encontrados (oo)cistos após o tratamento terciário realizado através da filtração lenta em areia. Houve remoção estatisticamente maior na ETE em escala plena para coliformes totais e Clostridium perfringens. E. coli e cistos de Giardia, em ambas ETEs, apresentaram remoções similares. Elevadas concentrações de (oo)cistos foram encontradas no lodo de esgoto, com grande porcentagem ainda viável. Com relação à desinfecção, entre as bactérias indicadoras, Clostridium perfringens foram mais resistentes ao cloro, ozônio e radiação ultravioleta. O efeito sinérgico, promovido pelas desinfecções sequenciais (clororadiação ultravioleta e ozônio-radiação ultravioleta), foi evidenciado em alguns experimentos para todas as bactérias estudadas. O cloro alterou a fluorescência dos cistos de Giardia e o ozônio, além de alterar a fluorescência, foi capaz de diminuir a concentração de cistos desse microrganismo. Pode-se concluir que as concentrações tanto de microrganismos indicadores como de protozoários patogênicos é bastante elevada, qualquer que seja o tipo de esgoto: bruto, efluente do reator UASB ou efluente do lodos ativados. Isso evidencia o extremo cuidado com que estes efluentes devem ser tratados, para posteriores usos ou lançamento em corpo receptor, em especial devido à presença de (oo)cistos ainda viáveis de Giardia spp. e Cryptosporidium spp. mesmo após o tratamento biológico por lodos ativados, e a necessidade de desinfecção do efluente. / This work aimed to evaluate the efficiency of removal of pathogenic protozoa - Giardia spp. and Cryptosporidium spp. - during wastewater treatment by UASB reactor, activated sludge, slow sand filter and different disinfectants. The recovery of Giardia cysts and of Cryptosporidium oocysts, performed by different methodologies and using ColorSeed®, was respectively of 85 and 20%, in raw wastewater and 62.5 and 17.5% in treated effluent, applying triple centrifugation method. Giardia cysts were found in 100% of the the sewage samples surveyed, with average of 1.5 x 104 cysts per liter and Cryptosporidium oocysts were found in 31.4% with average of 3.1 x 10² oocysts per liter, in raw wastewater. Giardia cyst and Clostridium perfringens spores removals were statistically lower than E. coli and total coliforms removal when applying the biological treatment by UASB reactor followed by Activated Sludge. There were no (oo) cysts after treatment tertiary accomplished by slow sand filtration. There was a statistically higher removal in the full scale WWTP for total coliforms and Clostridium perfringens; however, E. coli and Giardia cysts, in both WWTPs, presented the same removal efficiency. High concentrations of (oo)cysts were found in the sludge sludge, with a high percentage still viable. Regarding disinfection, among the indicating bacteria, Clostridium perfringens was more resistant to chlorine, ozone and ultraviolet radiation. The synergic effect promoted by sequential disinfections (chlorine-ultraviolet radiation and ozone-ultraviolet radiation) was evidenced in some experiments for all the bacteria studied. Chlorine altered the fluorescence of Giardia cysts and ozone, as well as change in fluorescence was able to decrease the concentration of this microorganism. It can be concluded that the concentrations of indicator microorganisms as well as of pathogenic protozoa is very high, regardless the kind of wastewater: raw, UASB reactor effluent or activated sludge effluent. This shows the extreme care that must be taken towards these effluents, for future reuse or simply release in the environment, mainly due to the presence of viable Giardia spp. and Cryptosporidium spp. (oo)cysts even after the activated sludge treatment, and the need of disinfection of the effluent.
50

Geração de metano em reator UASB: avaliação de parâmetros de monitoramento para controle do processo de tratamento anaeróbio de vinhaça / Methane generation in a UASB reactor: evaluation of monitoring parameters for control of anaerobic treatment process of vinasse

Longo, Rodrigo Rodrigues 29 May 2015 (has links)
Com o propósito de explorar o potencial de geração de metano a partir de vinhaça de cana-de-açúcar e propor procedimentos de controle do processo anaeróbio, foi utilizado um reator UASB (Upflow Anaerobic Sludge Blanket) em escala piloto, equipado de separador gás-sólido-líquido modificado e sem recirculação de efluente. A unidade foi inoculada com lodo granular e utilizou-se substrato concentrado (DQO de 20 g.L-1) para sua alimentação. O reator foi submetido a cargas orgânicas volumétricas (COV) de 0,7 a 7 KgDQO.m-3.d-1, durante 300 dias de operação. O procedimento operacional baseou-se no aumento de carga por escalonamento da vazão de alimentação em função da manutenção de variação inferior a 10% para a eficiência do sistema. Para o tamponamento da vinhaça de alimentação, no início da operação utilizou-se 1g NaHCO3.g-1DQOafluente, com redução gradativa até 0,125g NaHCO3.g-1DQOafluente. O monitoramento do desempenho do processo anaeróbio se deu pela avaliação dos parâmetros: eficiência de remoção de DQO, pH, alcalinidade, ácidos voláteis, razão alcalinidade intermediária/alcalinidade parcial, razão Prop:Ac, vazão de metano e porcentagem de metano no biogás. O reator UASB apresentou valor médio de eficiência de remoção de DQO de 92±4,4%, para cargas aplicadas entre 0,7 e 4,8 KgDQO.m-3.d-1. A maior produção média de metano observada durante o período operacional foi 5 m3CH4.m-3 de vinhaça aplicada para cargas orgânicas entre 4,1 e 5,6 KgDQO.m-3.d-1. A produção de biogás apresentou valor médio de metano de 70±7% para 1 a 5,6 Kg DQO.m-3.d-1. A operação do reator com cargas aplicadas acima de 5,6 KgDQO.m-3.d-1 gerou menor produção de biogás, redução na porcentagem de metano e aumento da carga de ácidos voláteis efluente, assim como queda na eficiência de remoção de DQO. Devido ao acréscimo de carga (0-2 para 4-6 KgDQO.m-3.d-1), a variação da concentração para cada tipo de ácido foi: acético (56±70 para 216±121 mg.L-1), propiônico (26±28 para 165±150 mg.L-1) e butírico (4±7 para 60±18 mg.L-1). Notou-se que a relação entre as concentrações de ácido propiônico e ácido acético (razão Prop:Ac) pode ser utilizada como parâmetro de monitoramento da estabilidade do reator. A elevação de COV de 3,9 a 6,4 KgDQO.m-3.d-1acarretou alteração na razão Prop:Ac de 0,8 a 1,75, corroborando descontroles do processo anaeróbio associado à queda de eficiência na geração de metano. / In order to explore the potential of methane generation from sugarcane vinasse and propose procedures for the anaerobic process control, was utilized a pilot scale UASB reactor (Upflow Anaerobic Sludge Blanket), equipped with modified gas-solid-liquid separator and without recirculation of effluent. The unit was inoculated with granular sludge and concentrated substrate was used (COD 20 g.L-1) for feeding. The reactor was submitted to volumetric organic load (VOL) from 0.7 to 7 KgCOD.m-3.d-1, during 300 days of operation. The reactor operation was based on the increase of load by staggering the feed flow in function of the maintenance of variation lower than 10% for the system efficiency. For buffering the feedings vinasse was used 1g NaHCO3.g-1CODinfluent at the beginning of the operation, with gradual reduction to the value of 0.125 g NaHCO3.g-1CODinfluent. The monitoring of the anaerobic process performance was due to the evaluation of the following parameters: efficiency of COD removal pH, alkalinity, intermediate alkalinity/partial alkalinity ratio; Prop:Ac ratio, methane flow and percentage of methane in the biogas. The UASB reactor demonstrated a COD average removal efficiency of 92±4.4%, to applied loads between 0.7 and 4.8 KgCOD.m-3.d-1. The highest average methane production observed during the operational period was 5 m3CH4.m-3 of vinasse applied for organic loads between 4.1 and 5.6 KgCOD.m-3.d-1. The biogás production demonstrated a methane average of 70±7% for 1 to 5.6 KgCOD.m-3.d-1. The reactor operation with loads up to 5.6 KgCOD.m-3.d-1 caused lower production of biogas, reduction in the percentage of methane and increase for effluent volatile acids load, as well as decrease of COD removal efficiency. Due to the additional load (0-2 to 4-6 KgCOD.m-3.d-1), the change in concentration for each type of acid was: acetic acid (56±70 to 216±121 mg.L-1), propionic acid (26±28 to 165±150 mg.L-1) and butyric acid (4±7 to 60 ± 18 mg.L-1). It was noted that the relationship between the concentrations of propionic acid and acetic acid (ratio Prop:Ac) may be used as a monitoring parameter of the reactor stability. The increase in VOL of 3.9 to 6.4 KgCOD.m-3.d-1 caused change in the Prop:Ac ratio of 0.8 to 1.75, confirming the upsets on the anaerobic process associated with efficiency drop in methane generation.

Page generated in 0.0604 seconds