• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Absolute Längenmessung prismatischer Körper mit dem beidseitig antastenden Interferometer der PTB

Skupin, Katharina 29 July 2020 (has links)
In vorliegender Arbeit werden Aufbau und Charakterisierung des beidseitig antastenden Interferometers vorgestellt, mit dem die absolute Länge prismatischer Körper ohne Anschub an eine Referenzplatte gemessen werden kann, was Verformungen durch Wechselwirkungen von Endmaßen mit angeschobenen Platten verhindern kann. Die Messunsicherheit im Vergleich zum Prototypen konnte aufgrund eines verbesserten Temperaturmesssystems, eines temperaturstabilisierten Vakuumkessels, Optiken mit besserer Ebenheit und Kameras größerer Auflösung deutlich reduziert werden. Das entwickelte Justageverfahren mit Autokollimationsscan und die Korrektur von Wellenfrontaberrationen tragen ebenso zu einer reduzierten Messunsicherheit bei, wie der durch optimale Ausrichtung der keilförmigen Strahlteilerplatten reduzierte Einfluss von Störinterferenzen. Vergleichsmessungen eines Stahl- und eines Filterglasendmaßes mit einseitig antastenden Interferometern zeigten mit Differenzen im Bereich von 0,4 bis 2,6 nm im Rahmen der Unsicherheiten konsistente Probenlängen, was die gute Eignung des beidseitig antastenden Interferometers für absolute Längenmessungen zeigt. Vergleichsmessungen an Silizium ergaben für die beidseitig antastend gemessenen Längen gegenüber im einseitig antastenden Interferometer gemessenen Längen deutlich geringere Werte und eine reproduzierbare Differenz zwischen den mit 532 und 633 nm gemessenen Längen von etwa 4 nm. Diese Effekte sind vermutlich auf die sich beim beidseitig antastenden Verfahren deutlich stärker auswirkenden Material- und Oberflächeneigenschaften zurückzuführen. Das volle Potential des beidseitig antastenden Interferometers entfaltet sich aufgrund des großen Messunsicherheitsbeitrages der Rauheit und des Phasensprungs bei der Reflexion vor allem bei der Messung von Längenänderungen, wie der thermischen Ausdehnung oder der Langzeitstabilität verschiedener Materialien, für die die Effekte der Rauheit und des Phasensprungs eine vernachlässigbare Rolle spielen. / The present thesis adresses the setup and characterization of PTB´s double-ended interferometer, which allows for absolute length measurement of prismatic bodies without the need for wringing to a platen, which prevents deformation caused by their interaction. In comparison with PTB´s prototype, the measurement uncertainty has been substantially reduced due to an improved temperature measurement system, a temperature stabilized vacuum chamber, optics of better flatness and cameras with higher resolution. Further reduction of the measurement uncertainty has been achieved by the developed adjustment procedure including an autocollimation scanning and a correction of the influence of wavefront aberrations. Multiple configurations of orientation of the beamsplitter plate wedges were tested to minimize the influence of parasitic interferences. Comparison measurements against single-ended interferometers on a steel and a filter glas gauge block resulted in deviations of the measured length in the range of 0.4 to 2.6 nm, which is in good agreement with measurement uncertainties. This proves the capability of absolute length measurement of the double-ended interferometer. Comparison measurements on silicon gauge blocks resulted in significantly shorter lengths than those measured in single-ended interferometers with a reproducible length difference of 4 nm for the different used wavelengths of 532 and 633nm. Those effects are presumably based on material and surface characteristics which seem to have a much stronger impact on the measured length when the sample is not wrung to a platen. Due to the large contribution of the roughness and the phase change on reflection to the measurement uncertainty, the full potential of the double ended interferometer will unfold for measurements on lengths changes, like measurement of the thermal expansion or long term stability of different materials, for which the influence of the roughness and phase change on reflection can be neglected.
2

Piezoelectrically tunable optical cavities for the gravitational wave detector LISA

Möhle, Katharina 23 May 2013 (has links)
LISA (Laser Interferometer Space Antenna) ist ein geplanter Gravitationswellendetektor, der aus drei Satelliten bestehen soll, deren Abstand mit Hilfe von Laserinterferometrie überwacht wird. Die hohe Frequenzstabilität der Laser, die dafür benötigt wird, soll mit einem dreistufigen Verfahren erreicht werden. Dieses beinhaltet eine Vorstabilisierung, die nicht nur hohe Stabilität sondern auch Durchstimmbarkeit aufweisen muss. Eine Möglichkeit so eine durchstimmbare Vorstabilisierung zu realisieren ist die Verwendung eines optischen Resonators mit eingebautem Piezoaktuator. Dies ist an sich kein neuer Ansatz, wurde bisher allerdings noch nicht mit der geforderten Stabilität realisiert. Im Rahmen dieser Arbeit wurden verschiedene piezoelektrisch durchstimmbaren Resonatoren aufgebaut und hinsichtlich ihres Rauschverhaltens und Durchstimmbereichs untersucht. Dabei konnte gezeigt werden, dass die Resonatoren alle Anforderungen an eine durchstimmbare Vorstabilisierung für LISA erfüllen. Darüber hinaus gibt die hier präsentierte Arbeit einen neuen Einblick in das Potential von piezoelektrisch durchstimmbaren Resonatoren. Ihre Stabilität ist nur eine Größenordnung geringer als die der besten nicht durchstimmbaren Resonatoren der gleichen Länge und das gemessene Rauschen kann dabei nicht nicht den Piezoaktuatoren zugeordnet werden. Es sollte also prinzipiell möglich sein noch bessere Stabilitäten mit piezoelektrisch durchstimmbaren Resonatoren zu erzielen. In der Tat zeigen theoretische Untersuchungen, die im Rahmen dieser Arbeit durchgeführt wurden, dass die intrinsische Stabilität eines Resonators durch den Einbau eines Piezoaktuators nur geringfügig herab gesetzt wird. Hoch-stabile piezoelektrisch durchstimmbare Resonatoren können über eine Verwendung in LISA hinaus auch bei zahlreichen anderen Anwendungen zum Einsatz kommen, wie z.B. in der Cavity Enhanced Spektroskopie als Transfer Resonatoren oder als optische Lokaloszillatoren in der Atom- und Molekülspektroskopie. / The Laser Interferometer Space Antenna (LISA) is a proposed space-based gravitational wave detector that aims to detect gravitational waves in the low frequency range from 0.1 mHz to 1 Hz, which is not accessible by ground-based detectors. It consists of three satellites whose distance is monitored by laser interferometry. The high frequency stability of the lasers required for this purpose is to be achieved with a three level noise reduction scheme. This includes a pre-stabilization stage that has to feature not only high stability but also tunability. One approach for such a tunable pre-stabilization is stabilizing a laser to an optical cavity with incorporated piezoelectric actuator. While this is not a new concept per se, it has never been realized with the required stability until now. Within this thesis, different types of piezo-tunable cavities have been built and thoroughly analyzed. It could be shown that the cavities fulfill all requirements for a tunable laser pre-stabilization for LISA. Furthermore, the work presented here gives a new insight into the potential of piezo-tunable cavities. Their performance is only one order of magnitude below that of the best non-tunable cavities of the same length and the measured noise can not be attributed to the integration of the piezo actuators. So, in principal, an even better performance should be achievable with piezo-tunable cavities. Indeed, theoretical considerations performed within this thesis reveal that the intrinsic stability of piezo-tunable cavities is only slightly inferior to that of rigid cavities. Beyond an application in LISA, highly stable piezo-tunable cavities are also valuable devices for numerous other applications. They can be used in cavity enhanced spectroscopy, as transfer cavities or as optical local oscillators in atomic and molecular spectroscopy.
3

Femtosekunden Nahfeldspektroskopie an einzelnen Halbleiterquantenpunkten

Günther, Tobias 22 May 2003 (has links)
In dieser Arbeit werden erstmals die nichtlinearen optischen Eigenschaften einzelner Halbleiterquantenpunkte mit Femtosekunden-Zeitauflösung untersucht und dargestellt. Insbesondere die Besetzungs- und Polarisationsdynamik eines einzelnen Halbleiterquantenpunkts wird diskutiert. Zur Durchführung der Experimente wird eine neuartige Messmethode entwickelt und eingesetzt: die Femtosekunden-Nahfeldspektroskopie. Die Kombination aus fs-Anrege-Abtast-Spektroskopie und optischer Nahfeldspektroskopie ermöglicht es, die nichtlinearen optischen Eigenschaften eines einzelnen Quantenpunkts mit hoher räumlicher, temporaler und spektraler Auflösung bei Temperaturen von 10 K bis 300 K zu untersuchen. Das zu diesem Zweck weiter entwickelte optische Nahfeldmikroskop bietet eine hohe räumliche Auflösung von bis zu 150 nm. Die Einführung einer neuartigen optischen Abstandsregelkontrolle sichert identische experimentelle Bedingungen über zahlreiche Stunden, ohne daß mechanische Wechselwirkungen zwischen den untersuchten Strukturen und dem apparativen Aufbau die Ergebnisse negativ beeinflussen. Durch die Kombination dieses Nahfeldmikroskops mit einem klassischen fs-Anrege-Abtast-Aufbau können die nichtlineare optische Eigenschaften einzelner Quantenpunkte mit einer Zeitauflösung von bis zu 150 fs untersucht werden. Zur Charakterisierung der Mehrfachquantenfilmprobe werden die linearen optischen Eigenschaften einzelner Interface Quantenpunkte mit Hilfe der stationären Methoden der Photolumineszenzspektroskopie und Photolumineszenz-Autokorrelationsspektroskopie untersucht und analysiert. Dadurch bietet sich die Möglichkeit der gezielten Untersuchung der räumlichen Statistik lokalisierter Zustände. Einblick in die räumliche Unordnung des zugrundeliegenden Potentialverlaufs kann gewonnen werden. In PL-Emission wird der Übergang von homogen verbreiterten Emissionslinien dicker Quantenfilme in ein inhomogen verbreitertes Emissionsspektrum bei gleichzeitiger Beobachtung spektral scharfer Emissionslinien einzelner lokalisierter Exzitonenresonanzen mit Abnahme der Filmdicke beobachtet. In PL-Autokorrelationsexperimenten wird ein zweites ausgeprägtes Korrelationsmaximum beobachtet. Dieses wird einem angeregten lokalisierten und optisch aktiven Zustand zugeschrieben. Die beobachtete Energiedifferenz zwischen Exzitonengrundzustand und dem beobachteten angeregten Zustand ermöglicht eine Abschätzung des Dipolmoment zu 40-50D und der Ausdehnung von Quantenpunkte von ca. 50nm. Zeitaufgelöste Untersuchungen an interface Quantenpunkten werden mit einer spektralen Auflösung von 60 µeV in Reflexionsgeometrie durchgeführt. Diese gestatten zum einen die Bestimmung der Lebensdauer und Dipolmomente lokalisierter Exzitonenzustände. Zum anderen ist eine nahezu vollständige Rekonstruktion der Polarisationsdynamik nach optischer Anregung möglich. Grossen Einfluss auf die spektrale Form der detektierten Reflektivitätsänderung besitzt die Tiefe unter der ein Quantenpunkt unter der Oberfläche vergraben ist. Diese Tiefenabhängigkeit wird in dieser Arbeit genauer untersucht und analysiert. Weiterhin wird erstmals die Polarisationsdynamik in einem einzelnen Quantenpunkt mit fs-Zeitauflösung untersucht und analysiert. Wird die durch den Abtastimpuls getriebene Polarisation nicht durch Wechselwirkung mit einem zweiten Impuls gestört, wird eine exponentielle zeitliche Abnahme der Polarisation mit der durch die homogenen Linienbreite bestimmten Dephasierungszeit ermittelt. Vielteilchenwechselwirkung nach nichtresonanter Anregung mit einem Anregeimpuls führt zur Änderung der Polarisationsdynamik lokalisierter Zustände und zur Beobachtung nichtverschwindender Reflektivitätsänderungen zu negativen Verzögerungszeiten. Als dominanter Mechanismus der in den zeitaufgelösten Experimenten vorherrschenden Vielteilchenwechselwirkung wird ein anregungsinduziertes Dephasieren nachgewiesen. / In this thesis the first study of nonlinear optical properties of single Quantum Dots with femtosecond time resolution is presented. Especially the population and polarization dynamics in a single semiconductor quantum dot will be discussed. To achieve this goal a new experimental technology is developed, giving the possibility to investigate the temporal dynamics of a single quantum dot within a temperature range between 10 and 300 K. Hereby the combination of a standard pump-probe setup with a near-field microscope for variable temperatures allows highest temporal, spectral and spatial resolution of up to 100 fs, 60 ueV and 150 nm respectively. The introduction of a new optical distance control enables the investigation of nonlinear optical properties of a single quantum dot in reflection geometry without any restrictions due to masking or stress effects. In first experiments the linear optical properties of single interface Quantum Dots in the multiple quantum well structure is characterized and analyzed via PL- and PL-autocorrelation spectroscopy. Knowledge of the spatial statistics of localized states can be gained. Insight into correlation of the underlying disorder potential is achieved. By investigating different quantum wells the crossover from a homogeneous broadened emission spectra of thick quantum films to an inhomogeneous broadened emission spectra is observed accompanied by the occurrence of sharp emission peaks from localized excitons. In PL-Autocorrelation experiments a second pronounced correlation maximum is observed. This correlation maximum can be explained by a localized excited and optical active resonance in a single quantum dot. The energy difference between the localized ground state and the first excited state of about 3 meV allows a rough estimate of underlying dipole moments to 40-50 D and the extent of isolated quantum dots to 50 nm. Time resolved experiments on interface quantum dots are performed with a spectral resolution of 60 µeV in reflection geometry, allowing on one hand the determination of population life times and dipole moments of localized exciton states. On the other hand a nearly complete reconstruction of the polarization dynamics is possible. Large influence on spectral shape of the reflectivity change is given by the distance between interface quantum dots and the sample surface. This burying depth dependence will discussed and analyzed in detail within this thesis. Moreover polarization dynamics in a single quantum dot is investigated with fs-resolution. If the polarization driven by the probe pulse is not disturbed by a second light pulse, an exponential decay of the polarization amplitude with an decay time determined by the homogeneous line width is observed. Many body interaction after excitation by a non-resonant pump-pulse causes changes in the polarization dynamics of localized states at negative delay times. As prominent mechanism of many-body interactions governing the experiments an excitation induced dephasing will be determined.

Page generated in 0.0238 seconds