• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 662
  • 22
  • 10
  • 10
  • 10
  • 10
  • 9
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 707
  • 361
  • 97
  • 88
  • 75
  • 72
  • 64
  • 56
  • 50
  • 46
  • 41
  • 41
  • 39
  • 37
  • 35
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Influência da agitação ultrassônica do cimento obturador na ação antimicrobiana intra-dentinária e no preenchimento de istmos em canais mesiais de molares inferiores / Influence of ultrasonic agitation of the sealer on the intratubular antimicrobial activity and on the filling quality of isthmuses in mesial roots of mandibular molars

Alcalde, Murilo Priori 12 June 2015 (has links)
Avaliou-se presença de espaços vazios, presença de fendas na interface cimento/dentina, o perímetro de penetração do cimento obturador nos canais e nos istmos.e a ação antimicrobiana intra-dentinária do cimento endodôntico (AH Plus) quando submetido ou não a agitação ultrassônica no momento da obturação. Para a avaliação do preenchimento de istmos foram utilizadas 30 raízes mesiais de primeiros molares inferiores, as quais foram divididas em 2 grupos (n=15). A instrumentação foi realizada com o sistema reciprocante Reciproc (R25) e finalizado com instrumento rotatório Mtwo (35.04). Em seguida, o cimento AH Plus foi espatulado com Rodamina B e foi inserido nos canais com espiral de Lentulo no35; o cimento do grupo 1 foi submetido a agitação ultrassônica enquanto o do grupo 2 não foi agitado, sendo que todos os canais foram obturados por meio da técnica do cone único e armazenados em estufa a 37oC durante 7 dias. As raízes foram seccionadas transversalmente a 2, 4 e 6 mm do ápice radicular para análise em esteromicroscópio e microscopia confocal a laser. Para a avaliação da ação antimicrobiana foram utilizados 30 incisivos de bovinos, os quais foram seccionados em cilindros de 6 mm de espessura. Os canais tiveram seu diâmetro padronizado com uma lima tipo K no 80 e então contaminados com Enterococcus faecalis (ATCC 29212) por 4 dias. Após esse período os espécimes foram divididas em 3 grupos (n=30). No grupo 1 o cimento foi agitado com o ultrassom e obturados com a técnica de cone único; no grupo 2 o cimento não foi agitado e o grupo 3 foi o grupo controle. As raízes foram seccionadas longitudinalmente no sentido vestíbulopalatino e coradas com corante LIVE/DEAD para avaliar a viabilidade bacteriana em microscopia confocal a laser. Para análise da agitação ultrassônica do cimento obturador no preenchimento de canais e istmos, foi utilizado o teste não paramétrico de Mann-Whitney (p <0.05) e para a análise da ação antimicrobiana intradentinária, foi utilizado o teste não paramétrico Kruskal-Waliis e o Teste Dunn (p <0.05). Os resultados indicaram que a agitação ultrassônica do cimento AH Plus favoreceu o preenchimento de istmos e a penetração intratubular. A agitação ultrassônica do cimento AH Plus reduziu significantemente a viabilidade bacteriana. Conclui-se que a agitação ultrassônica do cimento AH Plus favoreceu maior penetração intratubular, menor presença de fendas, menos espaços vazios e maior ação antimicrobiana. / In this study it was assessed the presence voids, gaps in the sealer/dentin interface, the intratubular sealer penetration in canals and isthmuses and intratubular antimicrobial effect of the AH Plus sealer when ultrasonic activation was performed during obturation. 30 mesial roots of mandibular first molars were selected and divided into 2 groups (n=15). Root canal instrumentation was performed with the reciprocating system Reciproc (R25) and finished with the Mtwo (35.04) rotary instrument. Then the AH Plus sealer was mixed with Rhodamine B and was inserted into the root canals with a Lentulo spiral #35. In group 1 the ultrasonic activation of the sealer was performed while in group 2 was not activated. Then, the root canal filling was performed using the single cone technique. After 7 days of storage the roots were sectioned at 2, 4 and 6 mm from the apex and analyzed in the stereomicroscope and by confocal laser scanner microscopy. To the antimicrobial test 30 bovine incisors cut into cylinders with 6 mm in thickness were used. The root canals diameter was standardized with a K file # 80 and then contaminated with Enterococcus faecalis (ATCC 29212) for 4 days. After this period the samples were divided into 3 groups (n = 30). In group 1 the ultrasonic activation of the sealer was perfomed and filled with single cone technique; in group 2 the sealer was not ultrasonic activated and in group 3 the canals were not obturated (control group). The roots were sectioned in the buccal-palatal direction and stained with LIVE / DEAD stain to assess the bacterial viability by confocal laser microscopy. For analysis of ultrasonic activation of the sealer on the filling quality of the canals and isthmuses, a non-parametric Mann-Whitney test (p <0.05) was used. For the analysis of the intradentin antimicrobial action, a Kruskal-Waliis nonparametric and Dunn\'s test was used (p <0.05). The results showed that the ultrasonic agitation of the AH Plus sealer favored the isthmus filling and the intratubular penetration. Also, the ultrasonic activation of AH Plus sealer reduced bacterial viability. It was concluded that the ultrasonic agitation of the sealer favored higher intratubular penetration, lower presence of gaps and voids and higher antimicrobial activity.
232

Importância de três técnicas de preparo cavitário e de três sistemas adesivos na microinfiltração marginal em restaurações Classe V de resina composta / Importance of three techniques of cavity preparation and three adhesive systems on microleakage of composite resin restorations

Federici, Bruna Vitorazo 17 March 2010 (has links)
Este estudo in vitro avaliou a microinfiltração marginal de restaurações de classe V em resina composta, preparadas utilizando-se três técnicas de preparo cavitário: Alta-rotação (AR), ultrassom (US) e a associação das duas técnicas (AR+US); e restauradas após a aplicação de 3 sistemas adesivos, sendo um de condicionamento total (Single-Bond (SB)) e dois autocondicionantes (Clearfil SE Bond (CSE) e Prompt L-Pop (POP)). Foram formados nove grupos (n=14) com terceiros molares que tiveram cavidades preparadas em suas faces vestibular e lingual, e foram classificados como: Grupo1- AR/SB; Grupo 2 AR/CSE; Grupo 3 AR/POP; Grupo 4 US/SB; Grupo 5 US/CSE; Grupo 6 US/POP; Grupo 7 AR+US/SB; Grupo 8 - AR+US/CSE; Grupo 9 - AR+US/POP. Após a aplicação do adesivo as cavidades foram preenchidas com resina composta Z250-3M ESPE e armazenadas em água destilada a 37°C durante 24 horas. Posteriormente, as restaurações foram polidas e os espécimes termociclados (1000 ciclos/ 5 e 55°C), impermeabilizados, imersos em solução de nitrato de prata 50% por 8 horas, seccionados em 3 fatias, imersos em solução fotoreveladora por 16 horas e observados em microscópio óptico acoplado à uma câmera de vídeo. As imagens foram digitalizadas e um software foi utilizado para medir a microinfiltração marginal dos lados oclusal e cervical. Foi realizado ANOVA Split-plot que demonstrou não haver diferenças estatisticamente significantes para os lados oclusal e cervical (p<0.05). A média dos lados oclusal e cervical foi realizada e os dados submetidos à ANOVA 2 Fatores (p=0,05), que mostrou haver diferenças estatisticamente significante entre os grupos, sendo necessário a utilização de um Teste de Tukey (p=0,05). Este teste mostrou não haver diferenças estatisticamente significantes entre os grupos restaurados com o sistema adesivo de condicionamento total (SB), no entanto, os grupos restaurados com os adesivos CSE e POP apresentaram menor microinfiltração para os grupos preparados com US e AR+US. O Grupo US/CSE apresentou o menor índice de microinfiltração e o AR/POP o maior. Nas condições deste estudo, podemos concluir que o método de preparo das cavidades pode alterar a microinfiltração marginal para restaurações que utilizem sistema adesivo autocondicionante. / This in vitro study compared the microleakage of class V resin composite restorations placed in cavities prepared with high-speed dental bur (AR), ultrasonic preparation devices (US) and high-speed dental bur plus ultrasonic preparation devices(AR+US), and restored using three different adhesive systems (One all etch Single Bond (SB) , and two Self-etch Clearfil CSE bond (CSE), Prompt L-Pop (POP)). Nine groups (n= 14) of human third molars each were prepared on the bucal and lingual surfaces were formed: Group 1- AR/SB; Group 2 AR/CSE; Group3 AR/POP; Group4 US/SB; Group 5 US/CSE; Group 6 US/POP; Group 7 AR+US/SB; Group 8 - AR+US/CSE; Group 9 - AR+US/POP. Specimens were built up with Z250/3M ESPE composite and stored in distilled water at 37°C for 24 hours. Then, the restorations were polished and the specimens thermocycling (1000 cycles/ 5°- 55°C), put impermeable, immersed in a 50% silver nitrate solution for 8 hours, sectioned, immersed in a photographic developer solution at darkness for 16 hours, and analyzed for leakage at the oclusal and cervical interface using an optical microscope connected to a video camera. The images were digitalized and software was utilized for microleakage assessment. Upon analyzing the results using a Split-plot ANOVA no statistically significant differences (p<0,05) between the cervical and oclusal interfaces for all groups was observed. The average of the interfaces was held and a Two-Way ANOVA revealed differences in microleakage among the tested groups (p=0,05). Tukey Test for Multiple Comparisons (p=0,05) demonstrated no significant difference between the groups restored with total etch adhesive system (SB), the groups restored with CSE and POP showed the least microleakage for the group prepared with the US and AR/US. The group US/CSE had the lowest microleakage and the group AR/POP had the highest. In the conditions of this study, we can conclude that the method of cavity preparation may affect the microleakage when a selfetch adhesive system is used.
233

Análise qualitativa da remoção do magma dentinário do terço apical de raízes curvas após irrigação convencional, sônica e ultrassônica / Qualitative analysis of smear layer removal, in the apical third of curved canals, after sonic, ultrasonic and conventional irrigation

Gonçalves, Luciana Magrin Blank 05 April 2011 (has links)
No presente estudo foi realizado a análise qualitativa da remoção do magma dentinário do terço apical de raízes curvas, quando submetidos a irrigação convencional, irrigação ultrassônica passiva e irrigação sônica. Como corpos de prova, foram utilizados 62 canais mésio-vestibulares com curvatura entre 20° e 40° de molares inferiores. Todos os condutos, após odontometria, foram instrumentados com o sistema rotatório até a lima F2. Destes, dois condutos foram utilizados como controle negativo, e os outros sessenta foram divididos aleatoriamente em três grupos experimentais conforme sua irrigação final: G1- irrigação convencional com seringa e agulha; G2- irrigação ultrassônica passiva; G3- irrigação sônica com sistema EndoActivator®. Em todos os grupos experimentais, foram utilizados 5mL de EDTA 17% por 1 minuto e 5mL de NaOCl 2,5% por 30 segundos. A observação da região apical, após clivagem, foi realizada através de microscopia eletrônica de varredura em aumento de 1000X. Isto posto, as imagens obtidas foram avaliadas por 3 examinadores calibrados pelo sistema de 3 pontos. Da análise dos resultados, pelo teste de Kruskal-Wallis, pode-se observar que os sistemas sônico e ultrassônico removeram significativamente o magma dentinário, sem diferença estatística entre os grupos. Quando comparados estes sistemas com a irrigação convencional, ambos mostraram-se mais eficientes, sendo os dois grupos estatisticamente diferentes do grupo convencional. Conclui-se que a irrigação sônica e irrigação ultrassônica passiva apresentam resultados semelhantes, aumentando a remoção do magma dentinário no terço apical de raízes curvas. / The aim of this study is to qualitative evaluate, the smear layer removal in the apical third of curved canals, after sonic, ultrasonic and conventional irrigation. Sixty two mesiobuccal root canals of mandibular molar with curvature degree between 20 and 40 degrees, were shaped with rotary system ProTaper® until file F2, and occasionally divided into three experimental groups (n=20) and one control group (n=2). The control group received no final irrigation after fitting of the master cone. The experimental groups received those final irrigations: G1- conventional irrigation with no agitation of the irrigant; G2- passive ultrasonic irrigation; G3- sonic irrigation with EndoActivator® system. In all groups, a final irrigation with 5mL EDTA 17% for 1 minute and 5mL NaOCl 2,5% for 30 seconds was procedure. Root canals were split longitudinally and subjected to scanning electron microscopy at a magnification of 1000X. The presence of smear layer was evaluated by three calibrated observers using a three-score scale. The differences in smear layer scores between the experimental groups were analyzed with Kruskal-Wallis test. Concerning the activations groups, both removed significantly smear layer, with no statistical significant difference. There were statistical significant differences when comparing this systems with conventional irrigation, the activation systems removed significantly more smear layer. The sonic and ultrasonic irrigation, in a similar way, enhance the removal of the smear layer, in the apical third of curved canals.
234

Avaliação da influência do efeito de ultrassom na lixiviação de metais de placas de circuito impresso obsoletas. / Assessment of influence of ultrasound effect on metal leaching of obsolete printed circuit boards.

Santos, Denis Massucatto dos 20 March 2015 (has links)
Os equipamentos elétricos e eletrônicos (EEE) possuem uma grande importância na sociedade contemporânea, e estão presentes no cotidiano das pessoas de forma ubíqua. Com o aumento no consumo de EEE juntamente com a obsolescência precoce, surge um novo tipo de resíduo, chamado de Resíduos de Equipamentos Elétricos e Eletrônicos (REEE). Os REEE não devem ser descartados em aterros, pelo risco de contaminação e pelo desperdício de material. Assim, a reciclagem se faz necessária. As placas de circuito impresso (PCI) estão presentes na grande maioria do REEE e contem a maior variedade de metais, incluindo metais valiosos como Au, Ag, Pt e Cu. A complexidade torna a reciclagem destas placas muito difícil. Rotas hidrometalúrgicas tem surgido como uma alternativa mais limpa para o tratamento de PCI, em detrimento aos processos pirometalúrgicos. Nas rotas hidrometalúrgicas, os metais são extraídos pela lixiviação realizada por ácidos ou bases. O efeito ultrassônico tem sido empregado na síntese de novas substâncias e também em alguns casos no tratamento de resíduos. O processo central no uso de ultrassom é a cavitação acústica, capaz de produzir microbolhas na solução com temperatura da ordem de 5000 K e pressão de 500 atm localmente. Além disto, a implosão das bolhas de cavitação em meio heterogêneo causa um jato de solução na superfície, que pode alcançar velocidade de 100 m.s-1. Assim, esta tese tem como objetivo a investigação do efeito do ultrassom sobre PCI obsoletas. Dois efeitos foram investigados: o efeito da cominuição das PCI promovido pela cavitação e a influência da cavitação na lixiviação com ácido sulfúrico de Fe, Al e Ni. Os parâmetros investigados na cominuição foram: tipo de placa, granulometria da placa moída e potência de ultrassom. Os parâmetros de lixiviação avaliados foram: razão sólido-líquido (S/L), concentração de ácido e potência de ultrassom. Também foram realizados ensaios de lixiviação sonicados com meio oxidante. Foi feita a análise cinética para se determinar qual é o controle da reação de lixiviação. / Electric and Electronic Equipment (EEE) have a large importance on modern society, and are present in daily life in a ubiquitous manner. With the increase in consumption of EEE associated with planned obsolescence, a new type of waste arises: Waste of Electrical and electronic Equipment. WEEE shall not be disposed in landfills due to contamination risk and loss of valueable material. In this way, recycling is necessary. Printed Circuit Boards (PCB) are present in most of WEEE and contains the largest variety of metals, including the valuable ones, like Au, Ag, Pt and Cu. Complexity of PCB makes recycling difficult. Hydrometallurgical routes have emerged as cleaner alternative for PCB treatment, instead of pyrometallurgical ones. In hydrometallurgical routes, metals are extracted by leaching performed by acids or bases. Ultrasonic effect has been employed in synthesis of new substances and also in some cases in waste treatment. Acoustic cavitation is the central phenomenon in ultrasound processing, and it is capable in producing microbubbles with temperature of 5000 K and pressures of 500 atm locally. Furthermore, bubbles imploding near a surface cause a jet streaming, and it can reach velocity of 100 m.s-1. So, this thesis aims to investigate the effect of ultrasound on obsolete PCB. Two distinct effets were investigated: the effect of comminution of PCB promoted by cavitation and the influence of ultrasound in sulphuric acid leaching on metals Fe, Al and Ni. In comminution, the following parameters were investigated: type of board, initial particle size of boards and ultrasound power. Leaching experiments were conducted to evaluate influence of solid-liquid (S/L) ratio, acid concentration and power ultrasound. Ultrasonic leaching of metals in presence of oxidizing agent was also conducted. Kinetic analysis was performed in order to determine what kind of control affects the leaching reaction. Keywords: leaching; ultrasound; solid waste; electronic waste.
235

Formação de imagens de peças com superfícies curvas utilizando arrays ultrassônicos. / Formation of images of pieces with curved surfaces using ultrasonic arrays.

Matuda, Marcelo Yassunori 09 October 2014 (has links)
Em formação de imagens por ultrassom de objetos com superfícies curvas, em imersão, se as velocidades de propagação no ruído e no objeto forem muito diferentes os efeitos de refração precisam ser compensados. Nesse caso a posição e a forma da superfície precisam ser conhecidas. Neste trabalho a superfície é detectada pelo mesmo array linear que captura os sinais para a formação de imagem.Dois métodos rápidos de detecção de superfície foram propostos, um baseado em técnicas de formação de imagem e outro que utiliza informações de tempo de percurso de ecos extraídas diretamente dos sinais de ultrassom.Os dois métodos foram comparados,e o método baseado em imagem apresentou uma maior tolerância a erros nos sinais, enquanto o método baseado em tempo de percurso mostrou-se mais rápido.Com a superfície detectada, a imagem foi formada por combinação de imagens por abertura sintética, que apresentou uma boa resolução. O uso conjunto dos métodos de detecção de superfície propostos e da formação de imagem resultou em uma taxa de imagens que permite ensaios interativos,com processamento em uma CPU de uso geral. / In ultrasound imaging ofobjects with curved surface, in immersion, the refraction eects must be compensated for if the propagation speed in the uid is very dierent from the speed in the object. In this case the surface position and shape must be known. In this work the surface is detected by the same linear array that captures the signals for the image formation. Two fast methods for surface detection were proposed,one is based on image formation techniques and another utilizes the echotime-of-ight information directly from the ultra\\sound signals.The two methods were compared,and the image-based method was more tolerant of signal errors, while the time-of-ight-based method was faster. After the surface detection, the image was formed by combination of synthetic aperture images,with a good resulting resolution. The utilization of the proposed surface detection methods together with the image formation resulted in an image rate that allows interactive testing, with processing on a general-purpose CPU.
236

Hidrofone ultrassônico com piezoeletreto como elemento transdutor / Ultrasonic hydrophone with piezoelectret as transducer element

Medeiros, Leandro José de 14 March 2014 (has links)
Desde o ano 2000, o Grupo de Alta Tensão e Materiais (GATM) tem contribuído com suas pesquisas no desenvolvimento de processos para produção de novos transdutores piezoelétricos de materiais poliméricos, baseados na tecnologia dos piezoeletretos. Essa intensa investigação se justifica pelas excelentes propriedades piezoelétricas desses dispositivos, com atividade na ordem de centenas e até milhares de pC/N, ultrapassando o desempenho de algumas tradicionais cerâmicas. Destacam-se também nestes sensores, sua estrutura flexível e robusta, sua resposta na faixa de frequências ultrassônicas e seu baixo custo. Características estas que os tornam muito competitivos com os transdutores convencionais, cerâmicos e poliméricos, a exemplo do PZT e PVDF, respectivamente. Neste contexto, desenvolveu-se em 2009 no GATM um novo arranjo polimérico de múltiplos canais, em que filmes de teflon FEP foram termicamente moldados e depois expostos a um intenso campo elétrico (na ordem de kV), criando sensores com elevado coeficiente piezoelétrico. Esse novo dispositivo, batizado de Piezoeletreto de Canais Tubulares (PCT) foi construído por meio de um processo de fabricação organizado e controlado, diferentemente dos piezoeletretos vistos até então. No presente trabalho construiu-se um protótipo de hidrofone com elemento ativo dado por um filme de PCT, para aplicações de até 100 kHz e com uma eletrônica de pré-amplificação em 24 dB. O primeiro teste com o protótipo restringiu-se à obtenção da sua sensibilidade. Realizaram-se ainda testes de caracterização quanto ao padrão de diretividade e a relação sinal-ruído. A calibração foi feita em três diferentes modalidades de geração do sinal: AM, CW e Burst, todas de maneira comparativa com o auxílio de um hidrofone comercial. A sensibilidade média encontrada nas medidas foi de 0,142 mV/Pa (-196,93 dB re 1 V/&#956Pa) e, na ressonância (40 kHz) de 1,698 mV/Pa (-175,4 dB re 1 V/&#956Pa). A segunda fase de testes destinou-se a geração de imagens para diagnóstico clínico, baseada na técnica de Vibroacustografia (VA). Verificou- se a viabilidade do uso da VA com o mapeamento de dois objetos distintos, uma pequena esfera metálica de 1 mm de diâmetro e uma estrutura óssea. / Since 2000, the High-Voltage and Materials Group (GATM) has focused its research on developing new processes for manufacture piezoelectric transducers, from polymeric materials based on the piezoelectret technology. This intense research is justified by the excellent electromechanical properties of these devices, with piezoelectric coefficient in the order of hundreds up to thousands of pC/N, exceeding the performance of the most traditional ceramics. Other highlights of these sensors are the flexible and robust structure, its wide range response in ultrasonic frequencies and low cost. These characteristics make them very competitive with those conventional ceramic and polymeric transducers, such as the PZT and PVDF, respectively. In this context, in 2009 a new polymeric multiple film arrangement was laminated to create an open channel structure that after been exposed to an intense electric field (on the order of kV), produces a piezoelectric sensor with high piezoelectricity. This new device was built by an organized and controlled process, unlike the piezoelectrets seen so far. The main features inherent to tubular channels piezoelectret are the constructive uniformity, control of the resonance frequency and greater thermal stability, when compared to other piezoelectric polymers. Based on these tubular piezoelectrets, in the current study, a prototype of a 24dB preamplifier ultrasonic hydrophone was built. The first test with the prototype restricted to obtaining its sensitivity. Further tests were performed to characterize the pattern of directivity and signal-to-noise ratio. The calibration tests were conducted on three different approaches to signal generation AM, CW and Burst; all in a comparative manner with the aid of a calibration standard hydrophone. The results showed a transducer with average sensitivity of 0.142 mV/Pa (-196.93 dB re 1 V/&#956Pa), and the resonance region at 40 kHz with a sensitivity of 1,698 mV/Pa (-175.4 dB re 1 V/&#956Pa) and a unidirectional sensitive region. The feasibility of producing images by VA has been verified by mapping two distinct objects, a small metal sphere of 1 mm diameter and a bone structure.
237

Transdutor híbrido para medidas susceptométricas e ultrassônicas simultaneamente / Hybrid transducer for susceptométricas and ultrasonic measures simultaneously.

Bruno, Alexandre Colello 26 March 2010 (has links)
Este trabalho descreve a construção e caracterização de um novo transdutor dedicado às medições susceptométricas e ultrassônicas de amostras marcadas com partículas magnéticas. Este transdutor, denominado de magnetoacústico, consiste de um sistema híbrido formado pela junção de um Biossusceptômetro de Corrente Alternada (BCA) e um transdutor ultrassônico. Seu principio básico de funcionamento consiste na medida simultânea da magnetização de um meio material marcado com partículas magnéticas e das microvibrações da estrutura interna deste meio quando excitado por um campo magnético alternado externo gerado pelas próprias bobinas de excitação do BCA. Estudos in vitro foram realizados para auxiliar no desenvolvimento e caracterização do protótipo apresentado neste trabalho. A técnica de medida empregando este transdutor híbrido foi denominada de vibromagnetoacustografia. As amostras utilizadas consistiram de meios fluidos marcados com traçadores magnéticos (micropartículas de ferrita de tamanhos variando entre 30 m e 70 m de diâmetro). Foi avaliada a dependência da resposta do sistema com diferentes parâmetros físicos tais como: viscosidade do material base o qual foi misturado as partículas ferromagnéticas; concentração dessas partículas misturadas ao material base; frequência de oscilação do campo magnético de excitação; tensão nas bobinas de excitação e a distância entre a amostra e o transdutores. A resposta do transdutor magnetoacústico apresentou melhor relação sinal/ruído em torno de 200 Hz de frequência de magnetização, considerando uma concentração de 4% de ferrita. Acima desta concentração a viscosidade do material base era alterada e interferia na medida. As respostas do susceptômetro e do ultrassom Doppler contínuo possuem uma relação linear com o nível de tensão aplicada nas bobinas de excitação e uma dependência quase linear com baixas concentrações de partículas ferromagnéticas ( 4%). Também foi realizado um teste de repetibilidade no protótipo obtendo um desvio relativo de 0,94% e 0,25% nas medições Doppler e susceptométricas, respectivamente. A medida de vibração das micropartículas ferromagnéticas realizadas in vitro, usando um transdutor Doppler contínuo, apresentou alta sensibilidade para baixas concentrações de material ferromagnético inseridos em meio fluido (~ 1%). / This work describes the construction and characterization of a new transducer dedicated to the susceptometrics and ultrasonic measurements of samples labeled with magnetic particles. This transducer, called magneto-acoustic, consists of a hybrid system formed by the junction of an Alternating Current Biosusceptometer (ACB) and an ultrasonic transducer. Its basic operation principle is the simultaneous measurement of the magnetization and the internal structure micro-vibrations of a medium labeled with magnetic particles when excited by an external alternating magnetic field generated by the ACB excitation coils. In vitro measurements were performed to support the prototype development and characterization presented in this work. The measurement technique employing this hybrid transducer was called vibromagnetoacoustography. The samples consisted of fluid medium labeled with magnetic tracers (ferrite micro particles of diameter ranging from 30 m and 70 m). It was evaluated the system response dependence with different physical parameters such as: base material viscosity in which ferromagnetic particles was mixed; the particles concentration in the base material; the oscillation frequency of the magnetic field excitation; the voltage applied on magnetizing coils and the distance between sample and transducers. The magneto-acoustic transducer response showed a better signal to noise ratio for magnetization frequency around 200 Hz and a 4% ferrite concentration. Above this concentration the base material viscosity changed disrupting the measurements. The responses of susceptometer and Doppler ultrasound have a linear dependence with the applied voltage level in the magnetizing coils and an quasi linear dependence with low ferromagnetic particles concentrations (4%). A repeatability test was also performed to the prototype which indicated a deviation of 0.94% and 0.25% in the Doppler and susceptometric measurements, respectively. The vibration measurement of ferromagnetic micro-particles performed in vitro, using a Doppler transducer, showed high sensitivity to low ferromagnetic material concentrations (~1%) immersed in a fluid medium.
238

Avaliação da aplicação do ultrassom terapêutico em tendinites de equinos / Evaluation of therapeutic ultrasound application on equine tendinitis

Reis, Ana Guiomar Matos Santiago 30 June 2009 (has links)
Os equinos atletas, especialmente os cavalos de corrida, são frequentemente acometidos por lesões do sistema locomotor. A tendinite é uma enfermidade frequente, sendo o flexor digital superficial (TFDS) o mais acometido. Muitos dos métodos de tratamento para lesões de tendão são utilizados, mas poucos proporcionam cura eficiente e duradoura. Este trabalho tem por finalidade investigar o efeito do ultrassom terapêutico (UST) no processo de cicatrização do TFDS em equinos. Para tanto foram utilizados 20 equinos da raça Puro Sangue Inglês, com idade variando entre dois e nove anos, machos e fêmeas, distribuídos em três grupos (G1, G2 e G3). O G1 foi formado por oito animais, sendo que os TFDS de seus membros torácicos não foram infiltrados com colagenase e nem expostos ao UST. O G2 e o G3 foram compostos por seis animais cada. A indução da lesão foi realizada no terço médio do TFDS com 1ml da solução de colagenase (2,5mg/ml), em todos os membros torácicos dos animais do G2 e do G3. A cicatrização dos tendões foi acompanhada pelos exames clínicos e ultrassonográficos. Aleatoriamente, apenas um membro torácico de cada cavalo do G2 e do G3 foi tratado com UST, modo pulsado (ciclo de trabalho 20%), frequência de 1 MHz e intensidade 0,5 W/cm2 (SATA spatial average temporal average), por 5 minutos. Foram colhidas amostras de tecido tendíneo lesado no 15° dia após o início do tratamento (T15) no G2 para determinar a expressão das proteínas IGF-1, TGF-&beta;1 e PCNA por imunoistoquimica; no 60° dia após o início do tratamento (T60) no G3 para detectar e mensurar a variação da organização dos feixes de colágenos por análise da birrefringência. Não foram observadas diferenças clínicas entre os membros tratados e não tratados dos grupos G2 e G3. Por meio da avaliação ultrassonográfica observou-se que o tamanho e ecogenicidade do tendão, tamanho e ecogenicidade da lesão, alinhamento longitudinal das fibras dos membros tratados do G3 não diferiram de tendões normais (G1) (P>0,05). Não houve diferença estatística entre os grupos para a expressão de PCNA. Entretanto, os membros tratados do G2 apresentaram maior expressão do TGF-&beta;1, enquanto os membros não tratados apresentaram maior expressão para o IGF-1 (P<0,05). Os resultados da birrefringência mostraram diferença estatística significativa entre o G1 e os membros não tratados do G3 e, entre os membros tratados e não tratados do G3 (P<0,001). A análise dos resultados sugere que o tempo de tratamento com UST não foi suficiente no G2 para promover regeneração do tendão, mas alterou a expressão de IGF-1 e TGF-&beta;1, indicando aceleração do processo cicatricial. Já a irradiação do UST no G3 promoveu reorganização, agregação das fibras de colágeno e regeneração do tendão. Conclui-se que, este protocolo de tratamento de UST é eficaz tanto para acelerar o processo de cicatrização do tendão, como para melhorar a organização de suas fibras de colágeno. / Equine athletes are frequently afflicted with locomotor injuries, especially racing horses. Tendinitis is a common problem of lameness in horse, and then the superficial digital flexor tendinitis (SDFT) is the greatest affected. Many of the tendinitis methods of treatment have an empirical basis; but none has proved an effective cure. The purpose of this study was to evaluate the effects of therapeutic ultrasound (TUS) on equine SDFT healing process. It was submitted 20 thoroughbred horses, mares and stallions, between two and nine years old, which were divided into three groups (G1, G2 and G3). The G1 was composed of eight horses; no tendinitis was induced, so they did not received any treatment. G2 and G3 were composed of six animals each one. All G2 and G3 forelimbs received 1.0 ml of collagenase (2.5 mg/ml) in the middle of SDFT. Healing process was monitored by clinical and sonographic evaluations. Randomly, one forelimb from each horse of G2 and G3 was treated with TUS performed at a frequency of 1 MHz on pulsed mode, an intensity of 0.5 W/cm2 (SATA - spatial average temporal average), for 5 minutes. After 15 treatment days, a tendon biopsy was performed on G2 tendons and protein expression for IGF-1, TGF-&beta;1 and PCNA were determined by immunohistochemistry. After 60 treatment days, a tendon biopsy was performed on G3 with the purpose of detecting and measuring the organization of collagen fibers through birefringence. Results showed no statistically difference for clinical examination on G2 and G3 treated and untreated tendons. Sonographic evaluation parameters such as isoechogenicity of tendon and lesion, diminution of lesion and tendon cross-sectional area, good axial alignment of collagen fibers was demonstrated by G3 treated limbs compared with normal tendon (P>0,05). The results showed no statistically difference between G1 and G2 treated and untreated tendons cells for PCNA expression. However, ultrasound-treated tendon cells (G2) were stained more strongly for TGF-&beta;1; whereas untreated tendon cells (G2) stained more strongly for IGF-1. The results showed a statistically difference (P<0.001) between G1 x G3 untreated tendons and between G3 treated and untreated tendons. Our results suggest that G2 TUS treatment time was not sufficient to improve tendon regeneration; although it modified IGF-1 and TGF-&beta;1 expression, accelerating tissue healing rate. In addition, G3 TUS protocol improved the arrangement and aggregation state of the collagen fibril, and promotes tendon regeneration. In conclusion, this TUS protocol is effective either to accelerate tendon healing or to improve the arrangement of the collagen fibril.
239

Estudo de métodos para a determinação de As, Cd, Pb, Cr e Se em fertilizantes base orgânica por AAS e ICP OES / Study of methods for determination of As, Cd, Pb, Cr and Se in organic fertilizers by AAS and ICP OES

Leite, Diego Pereira 05 August 2015 (has links)
O objetivo desse trabalho foi o desenvolvimento de métodos analíticos com extração assistida por ultrassom para a determinação de As, Cd, Cr, Pb e Se em fertilizantes base orgânica por espectrometria de absorção atômica com forno de grafite (GF AAS) e espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES). Para o desenvolvimento de métodos onde se utiliza a extração assistida por ultrassom, além da escolha do dispositivo ultrassônico a ser utilizado, são necessárias as otimizações de parâmetros como concentração de ácido na solução extratora, tempo de extração e massa de amostra, de modo a se obter a máxima eficiência de extração. Foram utilizados dois dispositivos: o banho ultrassônico, equipamento largamente difundido em laboratórios de química e uma adaptação da sonda ultrassônica em banho, na ausência e na presença de borbulhamento com ar atmosférico para agitação da solução. Tendo sido definidos os dispositivos a serem utilizados, desenvolveu-se o primeiro método, onde foram empregados ácidos diluídos nas soluções extratoras (HNO3 e HCl). Após a otimizações dos parâmetros de concentração, tempo e massa, percebeu-se que As, Cd e Pb tiveram recuperações próximas a 100% em CRM de lodo de esgoto, o que não ocorreu para Cr e Se. As condições otimizadas para ambos os ácidos ficaram em 2% (v v-1) de ácido, com tempo de extração de 10 minutos e massa de amostra de 60 mg, sendo que os dispositivos ultrassônicos que obtiveram melhor eficiência foram o banho ultrassônico e a sonda (extração indireta) com borbulhamento de ar atmosférico. De modo a se obterem extrações quantitativas de Cr e Se, foi desenvolvido um segundo método, onde adicionava-se ácido concentrado diretamente na amostra. Foram feitas diluições da solução extratora antes e depois da extração, para se verificar a eficiência de extração em pequenos volumes de solução extratora. Nesse método, foram otimizados o volume de ácido concentrado adicionado, tempo de extração e massa de amostra. Houve a impossibilidade de borbulhamento devido ao pequeno volume de amostra, foram utilizados os dispositivos de banho ultrassônico e sonda (extração indireta). Foram observadas boas recuperações (entre 80% e 100%) para todos elementos com ambos os ácidos, com exceção do Se quando se adiciona HCl diretamente na amostra. As condições otimizadas foram de adição de 1000 &#181;L de HNO3, com tempo de extração de vinte minutos e massa de amostra de 30 mg e de 200 &#181;L de HCL, com tempo de extração de dez minutos e massa de amostra de 60 mg. Após o desenvolvimento dos métodos com CRM, foram determinadas as figuras de mérito para cada analito, onde os limites de quantificação de todos os elementos ficaram abaixo do exigido pela normativa brasileira. Os métodos foram aplicados em amostras de condicionadores de solo, substrato e fertilizante, utilizando-se a digestão assistida por microondas para comparação de resultados. Não foram encontrados teores quantificáveis de As, Cd e Se, enquanto o Pb foi quantificável apenas nas amostras digeridas por micro-ondas e o Cr pelos dois métodos. No entanto, para Cr, os resultados não foram concordantes, sendo que foi encontrado um maior teor desse elemento na digestão assistida por micro-ondas. / The aim of this work was de development of analytical methods by assisted ultrasound extraction for the determination of As, Cd, Cr, Pb e Se in organic fertilizers by Graphite Furnace Atomic Absorption Spectrometry (GF AAS) and Inductively Coupled Plasm Optical Emission Spectrometry (ICP OES). For methods\' development, which are employed the assisted ultrasound extraction, beyond the choice of the ultrasonic device that will be used, optimizations parameter like concentration of acid, time of extraction and sample mass are needed, in order to obtain maximum efficiency of extraction. Two devices were used in this work: the ultrasonic bath, that is widespread in chemical labs and a probe, wherein was made an indirect extraction in the presence and absence of atmospheric air bubbling. With the definition of the devices that will be used, the first method was developed, which were employed diluted acids as extractors (HNO3 e HCl). After the optimization of acid concentration, time of extraction and sample mass, the method was applied for the determination of As, Cd and Pb with recoveries near to 100% in sewage sludge CRM, but did not present good results for Cr and Se. The optimized conditions for both acids were 2% (v v-1) of concentration, 10 minutes of ultrasonication and 60 mg of sample mass. The better extraction efficiency was observed for ultrasonic bath and probe (indirect extraction) with atmospheric air bubbling. In order to obtain quantitative extractions of Cr and Se, a second method was developed, based on direct addition of concentrated acid on the sample and ultrasonication. The dilution of the extractor solution was made before and after the extraction, in order to verify the efficiency of the extraction. In this method, the volume of acid, time of extraction and sample mass were also optimized. Due to the small volumes it is was not possible of bubbling air during the extraction using ultrasonic bath and probe (indirect extraction). Good recoveries were obtained for all analytes with both acids, excepting the recovery of Se with directly addition of HCl. The optimized conditions for extraction with HNO3 were 1000 &#181;L, 20 minutes and 30 mg of sample mass. For the extraction with HCl, the parameters optimized were 200 &#181;L, 10 minutes and 60 mg of sample mass. After the development of both methods with CRM, the figures of merit for each analyte were determined and the methods were applied in soil conditioners, substrate and organic fertilizer samples. The results were compared with the microwave assisted digestion of the samples. There were not found quantifiacle levels of As, Cd and Se, while Pb was founded only in the samples prepared with microwave assisted digestion and Cr was determined in both methods. However, the results for Cr were not concordants, wherein was found a higher level in the microwave assisted digested samples.
240

Imaging methodologies applied on phased array ultrasonic data from austenitic welds and claddings / Métodos de imagem aplicados em dados de ultrassom phased array de soldas austeníticas e cladeados

Baiotto, Ricardo January 2018 (has links)
A crescente tendência de utilização de materiais austeníticos soldados e cladeados em componentes críticos em alguns setores industriais, como nas indústrias de óleo&gás e nuclear, leva a um aumento na demanda sobre ensaios não-destrutivos confiáveis na avaliação de sua integridade estrutural. Dentre os métodos utilizados na inspeção de soldas cladeados austeníticos estão os métodos de ultrassom por phased array, que são normalmente utilizados na detecção e localização de defeitos. No entanto, componentes com esse tipo de microestrutura são difíceis de inspecionar por phased array devido a anisotropia e inomogeneidade causadas pela microestrutura de grãos grosseiros que costumam levar ao aumento do nível de ruído, ao deslocamento de indicações e ao surgimento de indicações falsas. Sendo assim, a seleção de um método de phased array apropriado precisa levar em conta a habilidade do método em superar os problemas causados pela anisotropia e inomogeneidade. Esta tese apresenta dois métodos de imagem por phased array ultrassônico não-convencionais pensados como formas de ajudar na determinação da integridade de componentes onde soldas e cladeados austeníticos estão presentes. Ambos os métodos tem como base o método de foco total (TFM), sendo que o primeiro é uma extensão do método de leis de atraso adaptativas chamado Método de Foco Total de Atraso Adaptativo (ADTFM) e o segundo método usa fatores de coerência associado à imagens de TFM. A partir dos métodos de imagem aplicados é possível aumentar significativamente a qualidade das imagens por ultrassom em comparação com as imagens padrão obtidas por TFM, especialmente quando foi possível utilizar ambos os métodos combinados. / The increasing trend to use austenitic welded and cladded materials in critical components employed in some industrial sectors, such as the oil&gas and nuclear industries, leads to an increasing demand for their non-destructive assessment by reliable non-destructive methods. Among the methods used to access the integrity of austenitic welds and claddings are the Ultrasonic Phased Array methods, which are usually used to detect the presence and determine the position of defects. However, austenitic welds and claddings are challenging to inspect with Phased Array methods due to the anisotropy and inhomogeneity caused by their coarse grain microstructure, which is capable of increasing noise levels, misplace indications and create false indications. Therefore, the selection of an appropriate phased array method needs to take into account the method’s ability to overcome the impairment caused by anisotropy and inhomogeneity. This thesis presents two non-conventional methods based on ultrasonic phased array imaging techniques designed to assist the structural integrity assessment of components where austenitic welds and clads are present. Both proposed methods are based on the Total Focusing Method (TFM); the first approach is an expansion of the adaptive delay laws concept named Adaptive Delay Total Focusing Method (ADTFM), while the second method uses the coherence weights combined with the TFM images. From the imaging methods applied it was possible to significantly increase the quality of the ultrasonic images in comparison with the standard TFM, primarily when it was possible to combine both approaches.

Page generated in 0.0194 seconds