• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 662
  • 22
  • 10
  • 10
  • 10
  • 10
  • 9
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 707
  • 361
  • 97
  • 88
  • 75
  • 72
  • 64
  • 56
  • 50
  • 46
  • 41
  • 41
  • 39
  • 37
  • 35
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

Transmissão de produtos farmacêuticos tópicos através de energia ultra-sônica na regeneração de lesões da musculatura esquelética - enfoque morfológico

Morsoleto, Maria José Misael da Silva [UNESP] 07 March 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:53Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-03-07Bitstream added on 2014-06-13T19:28:25Z : No. of bitstreams: 1 morsoleto_mjms_me_rcla.pdf: 7645060 bytes, checksum: 099c490ad0b826dfff563df09d42b8e0 (MD5) / Este trabalho apresenta uma série de resultados referentes à utilização da transmissão de fármacos tópicos através de ondas ultra-sônicas (fonoforese), em lesão cirúrgica produzida no músculo tibial anterior de ratos Wisttar. O fármaco utilizado foi a hidrocortisona gel manipulada a 10%. Foram utilizados 42 ratos Wisttar machos, com 60 dias de idade e peso médio de 300,0 g ( 50,0 g), que foram submetidos à lesão cirúrgica na pata direita no músculo tibial anterior. Após 24 horas a área da lesão foi tratada com ultra-som tendo como gel acoplante hidrocortisona a 10%. A freqüência utilizada foi de 1,0 MHz e intensidade de 0,4 W/cm2 por 1 minuto, durante 14 dias consecutivos. Depois da terapia aplicada os ratos foram sacrificados, o músculo criofixado e cortado em criostato. As lâminas obtidas foram coradas por H/E, Tricrômico de Masson e Tricrômico de Mallory para serem fotografadas em fotomicroscópio Zeiss. O tecido analisado proveniente dos animais lesados, tratados com ultra-som e hidrocortisona a 10% (fonoforese) apresentam: após 1 dia de tratamento, fibras musculares seccionadas pela incisão já fagocitada com predomínio de células mononucleadas. Nos animais sacrificados após 3 dias de tratamento notamos a presença de mioblastos, alguns miotubos e neovascularização. Quando analisamos os tecidos dos animais sacrificados após 7 dias de tratamento, observamos a presença de reorganização dos tecidos musculares. Nos animais sacrificados 14 dias após o tratamento, as fibras musculares mostram-se em avançado estado de regeneração. O aparecimento precoce de mioblastos e raras fibras necróticas, a partir do terceiro dia de aplicação, levam-nos a concluir que o fármaco tópico anti-inflamatório consegue atravessar a barreira de tecidos biológicos através da transmissão da energia ultra-sônica, e assim acelerar a reconstituição do tecido lesado. / This work presents a series of referring results to the use of the transmission of topical pharmacs through ultrasonic waves (Phonophoresis) in a produced surgical injuries in previous in the tibialis anterior muscle of Wisttar rats. The used pharmac was hydrocortisone gel to 10%. We had been used, in these experiment 42 rats with 60 days years' old and 300,0 average weight of g ( 50,0 g). The animals had been submitted to the chirurgical injury in the right leg, in previous the tibiae muscle. After 24 hours the area of the injury was dealt with ultrasound with faceplate hydrocortisone gel to 10%. The used frequency was of 1,0 MHz and the intensity of 0,4 W/cm2, with a time of 1 minute of insomniac, during 14 days. After the therapeutically one applied the rats they had been sacrificed, the frost fixed and cut muscle in cryostat. The gotten blades had been stain by H/E, Gomori's Trichrome, Masson's Trichrome and Mallory's Trichrome to be photographed in Zeiss photomicroscope. The analyzed proceeding from the animals injured, treated with ultra-sound and hydrocortisone present: after 1 day of treatment, skeletal muscle staple fibers parted by the phagocyte incision already with predominance of mononuclear cells. After 3 days of treatment, in the sacrificed animals, it is noticed myoblasts, some multinucleated myofibers and new vessel. When one analyzes of the sacrificed animals after 7 days of treatment, observes it presence of reorganization of muscular. In the sacrificed animals 14 days after the treatment, visualizes muscular fibers in advanced state of regeneration. The precocious appearance of myoblasts and rare necrotic tissue as fibers to leaving of the third day of application of treatment lever to conclude that the topical pharmac obtained to cross the biological barrier through the transmission of the ultrasonic energy. Of this form the hydrocortisone is taken until the small farm of lesion.
212

Efeito da agitação do EDTA por meio ultrassônico ou pelo laser diodo de alta potência quanto extrusão apical, alteração de temperatura, resistência à fratura radicular, e a variação de pH na estrutura dentinária. /

Oliveira, Luiz Fernando de Freitas. January 2020 (has links)
Orientador: Fábio Luiz Camargo Villela Berbert / Resumo: Objetivo: O objetivo desse estudo foi avaliar protocolos de agitação do EDTA aplicando dois diferentes tipos lasers de diodo de alta potência, comparando-os com os métodos de agitação convencional e com o ultrassom, quanto à extrusão apical, alteração de temperatura, resistência à fratura radicular e análise de pH na dentina radicular. Material e Métodos: Essa pesquisa experimental ex-vivo, utilizou 120 pré-molares inferiores, unirradiculados, com ráizes retas, com rizogênses completa e com tamanho radicular superior a 16mm, pré-selecionados por meio de radiografia digital. Suas coroas foram removidas, padronizando as raízes em 16 mm, seguido do preparo com a lima K#15 K#20 e o sistema reciproc R25, R40 e R50, 1 mm aquém do comprimento real do dente, com irrigação durante o preparo com NaOCl a 2,5%. Os espécimes foram distribuídos aleatoriamente em 6 grupos segundo protocolos de irrigação final: AD- água destilada (controle), CV- inundação com EDTA 17% e agitação com lima K #50, PUI- inundação com EDTA 17% agitado com ultrassom (Passive ultrasonic irrigation-PUI), PUI/CUI- inundação com EDTA 17% agitado com ultrassom (PUI) e irrigação com água destilada, agitada com ultrassom (Continuous ultrasonic irrigation-CUI), TL- inundação com EDTA 17% agitado com laser diodo Thera Lase Surgery, e GE- EDTA 17% agitado com laser diodo Gemini. Após irrigação final, todos os dentes foram irrigados com água destilada para remoção do EDTA. Resultados: Na avaliação da extrusão apical foi real... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: The objective of this study was to evaluate EDTA agitation protocols by applying two different types of high-power diode lasers, comparing them with conventional agitation methods and with ultrasound, in relation to apical extrusion, temperature change, fracture resistance root and pH analysis in root dentin. Material and Methods: This ex-vivo experimental research used 120 lower premolars, uniradicular, with straight roots, with complete rhizogenesis and with root size greater than 16mm, pre-selected by means of digital radiography. Their crowns were removed, standardizing the roots by 16 mm, followed by preparation with the K # 15 K # 20 file and the reciproc system R25, R40 and R50, 1 mm below the actual length of the tooth, with irrigation during preparation with NaOCl to 2.5%. The specimens were randomly distributed into 6 groups according to final irrigation protocols: AD- distilled water (control), CV- flood with 17% EDTA and agitation with K # 50 file, PUI- flood with 17% EDTA agitated with ultrasound (Passive ultrasonic irrigation-PUI), PUI / CUI- flooding with 17% EDTA stirred with ultrasound (PUI) and irrigation with distilled water, stirred with ultrasound (Continuous ultrasonic irrigation-CUI), TL- flooding with 17% EDTA stirred with laser diode Thera Lase Surgery, and GE-EDTA 17% stirred with Gemini diode laser. After final irrigation, all teeth were irrigated with distilled water to remove EDTA. Results: In the evaluation of the apical extrusion, the... (Complete abstract click electronic access below) / Mestre
213

Estimativa do tipo de lesão em estruturas das coronárias usando nível de deformação em imagens de ultrassom intravascular. / Estimation of kind of tissue in coronary structure using the level of deformation in intravascular ultrasound images.

Moraes, Matheus Cardoso 07 December 2012 (has links)
Doenças coronárias causam a morte de milhões de pessoas anualmente. Uma dessas disfunções é a aterosclerose coronariana, acúmulo de placas lipídicas, fibrosas, e calcificadas na parede das coronárias. Esse acúmulo pode causar tromboses, infarto do miocárdio, ou morte cardíaca súbita. Porém, essas lesões apresentam graus distintos de periculosidade e elasticidade. As predominantemente lipídicas são de alto risco e elasticidade, enquanto as calcificadas e as fibrosas são mais estáveis e menos elásticas. O Ultrassom Intravascular (IVUS) é uma das modalidades de referência em diagnósticos e acompanhamento de doenças coronárias. Contudo, a imagem de IVUS pura fornece apenas informações subjetivas sobre vasos e placas; assim, é importante a criação de métodos e técnicas que possam tornar objetiva a análise dessa informação. Devido a isso, e levando em conta a riqueza de informações espaciais e temporais presentes nas imagens de IVUS, esse trabalho apresenta métodos de segmentação, e extração de características de lesões, que possibilitam a quantização de informações espaciais, e a discriminação de placas de baixo e elevado-risco. Consequentemente, fornecendo subsídios para diagnósticos, e procedimentos terapêuticos mais adequados. O método de segmentação combina Wavelet, Otsu, e Morfologia Matemática, para delineamento da parede do vaso. A avaliação do método foi feita usando 1300 imagens de IVUS, resultando em 92, 72% e 91, 9% de verdadeiros positivos, e 10, 7% e 9, 1% de falsos positivos, para o lúmen e borda da média adventícia, respectivamente. Adicionalmente, foi criado um método simples, para caracterização de placas a partir de suas propriedades mecânicas. Esse procedimento se baseia em computar um índice, chamado taxa de variação da área da placa, em imagens adquiridas pré e pós deformação do vaso e placas. Phantoms foram usados para avaliação, os resultados conseguidos com o índice proposto e um amplamente usado foram comparados. Uma correlação chegando à 99%, uma forte concordância usando Análise de Bland Altman, e Histogramas muito similares entre os dois índices, mostraram que o método proposto equivale ao já estabelecido. / Coronary diseases are the cause of death of millions of people annually. One of these dysfunctions is the coronary atherosclerosis, which is the accumulation of lipidic, fibrous and calcified plaques in the coronary wall. This accumulation may cause thrombosis, myocardial infarction and sudden cardiac death. Nonetheless, the kind of plaques offers different levels of dangerousness and elasticity. The highly lipidic plaques are very elastic, offers high risk, while the calcified and fibrous are more stable and less elastic. The Intravascular Ultrasound (IVUS) is the reference medical imaging modality for diagnostic and treatment of coronary diseases. However, the conventional IVUS images provides only anatomical vessel and plaque information; therefore, it is very important the creation of methods and techniques that could make objective the analysis of this information. Due to that, and taking into account the spatial and time information of IVUS images, this work presents methods of segmentation, and feature extraction of lesions, which make possible the quantization of spatial information, and the discrimination of high, and low risk plaques. Consequently, subsidies for diagnoses and more appropriate therapeutic procedures are provided. The segmentation method combines Wavelet, Otsu, and Mathematical Morphology, for the vessel wall delineation. The method evaluation was performed using 1300 IVUS images, resulting in 92, 72% and 91, 9% of true positives, and 10, 7% and 9, 1% of false positives, for the lumen and media adventitia border, respectively. Additionally, a simple method, for plaque characterization using the regarding mechanical properties was created. The procedure relies on computing an index, ratio of plaque area variation, in acquired images pre and post deformation procedure of vessel wall and plaques. Phantoms were used for evaluation. The results obtained by the proposed index, and a widely used one was compared. A correlation up to 99%, a strong agreement with Bland Altman, and similar Histograms between the two indexes demonstrated the equivalence between them; however, the proposed index is much simpler.
214

Estimativa do tipo de lesão em estruturas das coronárias usando nível de deformação em imagens de ultrassom intravascular. / Estimation of kind of tissue in coronary structure using the level of deformation in intravascular ultrasound images.

Matheus Cardoso Moraes 07 December 2012 (has links)
Doenças coronárias causam a morte de milhões de pessoas anualmente. Uma dessas disfunções é a aterosclerose coronariana, acúmulo de placas lipídicas, fibrosas, e calcificadas na parede das coronárias. Esse acúmulo pode causar tromboses, infarto do miocárdio, ou morte cardíaca súbita. Porém, essas lesões apresentam graus distintos de periculosidade e elasticidade. As predominantemente lipídicas são de alto risco e elasticidade, enquanto as calcificadas e as fibrosas são mais estáveis e menos elásticas. O Ultrassom Intravascular (IVUS) é uma das modalidades de referência em diagnósticos e acompanhamento de doenças coronárias. Contudo, a imagem de IVUS pura fornece apenas informações subjetivas sobre vasos e placas; assim, é importante a criação de métodos e técnicas que possam tornar objetiva a análise dessa informação. Devido a isso, e levando em conta a riqueza de informações espaciais e temporais presentes nas imagens de IVUS, esse trabalho apresenta métodos de segmentação, e extração de características de lesões, que possibilitam a quantização de informações espaciais, e a discriminação de placas de baixo e elevado-risco. Consequentemente, fornecendo subsídios para diagnósticos, e procedimentos terapêuticos mais adequados. O método de segmentação combina Wavelet, Otsu, e Morfologia Matemática, para delineamento da parede do vaso. A avaliação do método foi feita usando 1300 imagens de IVUS, resultando em 92, 72% e 91, 9% de verdadeiros positivos, e 10, 7% e 9, 1% de falsos positivos, para o lúmen e borda da média adventícia, respectivamente. Adicionalmente, foi criado um método simples, para caracterização de placas a partir de suas propriedades mecânicas. Esse procedimento se baseia em computar um índice, chamado taxa de variação da área da placa, em imagens adquiridas pré e pós deformação do vaso e placas. Phantoms foram usados para avaliação, os resultados conseguidos com o índice proposto e um amplamente usado foram comparados. Uma correlação chegando à 99%, uma forte concordância usando Análise de Bland Altman, e Histogramas muito similares entre os dois índices, mostraram que o método proposto equivale ao já estabelecido. / Coronary diseases are the cause of death of millions of people annually. One of these dysfunctions is the coronary atherosclerosis, which is the accumulation of lipidic, fibrous and calcified plaques in the coronary wall. This accumulation may cause thrombosis, myocardial infarction and sudden cardiac death. Nonetheless, the kind of plaques offers different levels of dangerousness and elasticity. The highly lipidic plaques are very elastic, offers high risk, while the calcified and fibrous are more stable and less elastic. The Intravascular Ultrasound (IVUS) is the reference medical imaging modality for diagnostic and treatment of coronary diseases. However, the conventional IVUS images provides only anatomical vessel and plaque information; therefore, it is very important the creation of methods and techniques that could make objective the analysis of this information. Due to that, and taking into account the spatial and time information of IVUS images, this work presents methods of segmentation, and feature extraction of lesions, which make possible the quantization of spatial information, and the discrimination of high, and low risk plaques. Consequently, subsidies for diagnoses and more appropriate therapeutic procedures are provided. The segmentation method combines Wavelet, Otsu, and Mathematical Morphology, for the vessel wall delineation. The method evaluation was performed using 1300 IVUS images, resulting in 92, 72% and 91, 9% of true positives, and 10, 7% and 9, 1% of false positives, for the lumen and media adventitia border, respectively. Additionally, a simple method, for plaque characterization using the regarding mechanical properties was created. The procedure relies on computing an index, ratio of plaque area variation, in acquired images pre and post deformation procedure of vessel wall and plaques. Phantoms were used for evaluation. The results obtained by the proposed index, and a widely used one was compared. A correlation up to 99%, a strong agreement with Bland Altman, and similar Histograms between the two indexes demonstrated the equivalence between them; however, the proposed index is much simpler.
215

Transmissão de produtos farmacêuticos tópicos através de energia ultra-sônica na regeneração de lesões da musculatura esquelética - enfoque morfológico /

Morsoleto, Maria José Misael da Silva. January 2003 (has links)
Orientador: Carlos Alberto Anaruma / Banca: Roberto Naves Domingos / Banca: Miriam Maria de Magalhães Oliveira / Resumo: Este trabalho apresenta uma série de resultados referentes à utilização da transmissão de fármacos tópicos através de ondas ultra-sônicas (fonoforese), em lesão cirúrgica produzida no músculo tibial anterior de ratos Wisttar. O fármaco utilizado foi a hidrocortisona gel manipulada a 10%. Foram utilizados 42 ratos Wisttar machos, com 60 dias de idade e peso médio de 300,0 g ( 50,0 g), que foram submetidos à lesão cirúrgica na pata direita no músculo tibial anterior. Após 24 horas a área da lesão foi tratada com ultra-som tendo como gel acoplante hidrocortisona a 10%. A freqüência utilizada foi de 1,0 MHz e intensidade de 0,4 W/cm2 por 1 minuto, durante 14 dias consecutivos. Depois da terapia aplicada os ratos foram sacrificados, o músculo criofixado e cortado em criostato. As lâminas obtidas foram coradas por H/E, Tricrômico de Masson e Tricrômico de Mallory para serem fotografadas em fotomicroscópio Zeiss. O tecido analisado proveniente dos animais lesados, tratados com ultra-som e hidrocortisona a 10% (fonoforese) apresentam: após 1 dia de tratamento, fibras musculares seccionadas pela incisão já fagocitada com predomínio de células mononucleadas. Nos animais sacrificados após 3 dias de tratamento notamos a presença de mioblastos, alguns miotubos e neovascularização. Quando analisamos os tecidos dos animais sacrificados após 7 dias de tratamento, observamos a presença de reorganização dos tecidos musculares. Nos animais sacrificados 14 dias após o tratamento, as fibras musculares mostram-se em avançado estado de regeneração. O aparecimento precoce de mioblastos e raras fibras necróticas, a partir do terceiro dia de aplicação, levam-nos a concluir que o fármaco tópico anti-inflamatório consegue atravessar a barreira de tecidos biológicos através da transmissão da energia ultra-sônica, e assim acelerar a reconstituição do tecido lesado. / Abstract: This work presents a series of referring results to the use of the transmission of topical pharmacs through ultrasonic waves (Phonophoresis) in a produced surgical injuries in previous in the tibialis anterior muscle of Wisttar rats. The used pharmac was hydrocortisone gel to 10%. We had been used, in these experiment 42 rats with 60 days years' old and 300,0 average weight of g ( 50,0 g). The animals had been submitted to the chirurgical injury in the right leg, in previous the tibiae muscle. After 24 hours the area of the injury was dealt with ultrasound with faceplate hydrocortisone gel to 10%. The used frequency was of 1,0 MHz and the intensity of 0,4 W/cm2, with a time of 1 minute of insomniac, during 14 days. After the therapeutically one applied the rats they had been sacrificed, the frost fixed and cut muscle in cryostat. The gotten blades had been stain by H/E, Gomori's Trichrome, Masson's Trichrome and Mallory's Trichrome to be photographed in Zeiss photomicroscope. The analyzed proceeding from the animals injured, treated with ultra-sound and hydrocortisone present: after 1 day of treatment, skeletal muscle staple fibers parted by the phagocyte incision already with predominance of mononuclear cells. After 3 days of treatment, in the sacrificed animals, it is noticed myoblasts, some multinucleated myofibers and new vessel. When one analyzes of the sacrificed animals after 7 days of treatment, observes it presence of reorganization of muscular. In the sacrificed animals 14 days after the treatment, visualizes muscular fibers in advanced state of regeneration. The precocious appearance of myoblasts and rare necrotic tissue as fibers to leaving of the third day of application of treatment lever to conclude that the topical pharmac obtained to cross the biological barrier through the transmission of the ultrasonic energy. Of this form the hydrocortisone is taken until the small farm of lesion. / Mestre
216

[en] A SEMIAUTOMATIC TECHNIQUE FOR THE SEGMENTATION OF THE FETUS IN 3D ULTRASOUND EXAMS / [pt] UMA TÉCNICA SEMIAUTOMÁTICA PARA A SEGMENTAÇÃO DO FETO EM EXAMES DE ULTRASSOM 3D

FRANCISCO CARVALHO GUIDA MOTTA 22 November 2018 (has links)
[pt] Exames de ultrassom possuem um importante papel na obstetrícia devido a seu baixo custo, baixo risco e sua capacidade de execução em tempo real. O advento da ultrassonografia tridimensional possibilitou o uso do volume fetal como medida biométrica para monitorar seu desenvolvimento. A quantificação do volume do feto requer um processo prévio de segmentação, que consiste na rotulação dos pixels pertencentes ao objeto de interesse em uma imagem digital. Não existe, entretanto, um método padrão para a realização da volumetria fetal e a maioria dos estudos conta com a realização de segmentações manuais, que demandam uma alta carga de trabalho repetitivo. A segmentação de imagens de ultrassom é particularmente desafiadora devido à presença de artefatos como o ruído speckle e sombras acústicas e ao fato de que o contraste entre as regiões de interesse é muitas vezes baixo. Neste trabalho, desenvolvemos e testamos um método semiautomático de segmentação do feto em exames de ultrassom 3D. Devido às dificuldades citadas, bons métodos de segmentação em imagens de ultrassom devem fazer uso de características esperadas das estruturas específicas a serem segmentadas. Esse pensamento guiou o desenvolvimento da nossa metodologia que, através uma sequência de passos simples, antingiu bons resultados quantitativos na tarefa de segmentação. / [en] Ultrasound exams have an important role in obstetrics due to its low cost, low risk and real-time capabilities. The advent of three-dimensional ultrasonography has made possible the use of the fetal volume as a biometric measurement to monitor its development. The quantification of the fetal volume requires a previous process of segmentation, which consists in the labelling of the pixels that belong to the object of interest in a digital image. There isn t, however, a standard methodology for fetal volumetry and most studies rely on manual segmentations. The segmentation of ultrasound images is particularly challenging due to the presence of artifacts as the speckle noise and acoustic shadows, and the fact that the contrast between regions of interest is commonly low. In this study, we have developed and tested a semiautomatic method of fetal segmentation in 3D ultrasound exams. Due to the aforementioned difficulties, good ultrasound segmentation methods need to make use of expected characteristics of the specific segmented structures. This thought has guided the development of our methodology that, through a sequence of simple steps, achieved good quantitative results in the segmentation task.
217

[en] SUSCEPTIBILITY OF DIFFERENT NON-DESTRUCTIVE TESTS FOR INDICATION OF FATIGUE CRACKS / [pt] SUSCEPTIBILIDADE DE DIFERENTES ENSAIOS NÃO DESTRUTIVOS PARA INDICAÇÃO DE TRINCAS DE FADIGA

IVAN RAMALHO TONIAL 28 August 2017 (has links)
[pt] Ensaios não-destrutivos são técnicas utilizadas na inspeção de materiais e equipamentos sem danificá-los, sendo executados nas etapas de fabricação, construção, montagem e manutenção. Constituem uma das principais ferramentas do controle e garantia da qualidade de materiais e produtos, sendo largamente utilizados nos setores petróleo/petroquímico, químico, aeronáutico, aeroespacial, siderúrgico, naval, eletromecânico, papel e celulose, entre outros. Representam métodos capazes de proporcionar informações sobre defeitos, características tecnológicas do material, ou ainda, monitoração da degradação em serviço de componentes, equipamentos e estruturas, o que permite o uso de ações de extensão de suas vidas úteis. O objetivo desta pesquisa foi comparar a adequação de diferentes técnicas não destrutivas na detecção e estimativa da dimensão de trincas de fadiga, nucleadas e propagadas intencionalmente, em material estrutural. Para tal, corpos de provas cilíndricos do aço 42CrMo4 com um entalhe em V sofreram carregamentos cíclicos até diferentes números de ciclos, o que proporcionou diferentes tamanhos de trinca. O comprimento das trincas passantes foi monitorado por meio de lupa posicionada na lateral do corpo de prova. Após a etapa de nucleação e propagação das trincas de fadiga, todos os corpos de prova foram inspecionados com emprego das técnicas de Ultrassom Convencional, Ultrassom Phased Array e Radiografia Digital, para permitir a indicação das trincas de fadiga e o estabelecimento de suas dimensões. Terminada as inspeções, os corpos de prova foram resfriados em nitrogênio líquido e fraturados com aplicação de uma carga de flexão, o que permitiu a visualização das superfícies das trincas. Em seguida, as trincas foram medidas visualmente com o auxílio de uma lupa, o que permitiu comparar as indicações (virtual) de defeitos nos corpos de prova com a existência (real) dos mesmos e, ainda correlacionar as dimensões indicadas nas inspeções com aquelas medidas nas superfícies das trincas. Neste contexto, todas as técnicas se mostraram adequadas para a indicação de defeitos. Além disso, para trincas curtas, o Ultrassom Phased Array foi a técnica que apresentou a melhor suscetibilidade para o dimensionamento de descontinuidades, enquanto que a Radiografia Digital se mostrou mais eficiente para trincas mais longas. / [en] Non-destructive tests are techniques used in material and equipment inspection without permanent damage, applied in the stages of manufacture, construction, assembly and maintenance. They are one of the main tools to control and insure the quality of materials and products, with widely applications in oil / petrochemical, chemical, aeronautical, aerospace, steel industry, naval, electromechanical industries. They represent with capacity of providing information about defects, technological characteristics of the material, or monitoring the degradation in service of components, equipment and structures, which allows the use of useful live extensions in service. The objective of this research was to compare the application of different non-destructive techniques in the detection and size estimation of fatigue cracks, nucleated and propagated intentionally, in structural material. For this purpose, cylindrical specimens of 42CrMo4 steel with a V-notch were subjected to cyclic loading with different cycle numbers, which provided different crack sizes. The length of the cracks was monitored by a magnifying glass positioned on the specimen surface. After the crack nucleation and propagation, all specimens were subjected to non-destructive tests making use of Conventional Ultrasound, Phased Array Ultrasound and Digital Radiography, in order to provide crack indications and crack dimensions. After the inspections, the specimens were cooled down in nitrogen and fractured in three point bending to promote opened crack surfaces. In the sequence, the cracks were measured using a magnifying glass, which allowed a comparison between the indicated and measured defects. In this context, all techniques were adequate for crack indications. On the other hands, for short cracks, the Phased Array Ultrasound was the technique that presented the best susceptibility for estimate the discontinuity dimensions, while Digital Radiography proved to be more efficient for longer cracks.
218

Análise quantitativa da imagem ultra-sonográfica de testículos de bovinos jovens da raça Nelore /

Cardilli, Diogo José. January 2008 (has links)
Resumo: O exame ultra-sonográfico dos testículos é um método não invasivo e rápido, que aliado aos dados de exame clínico, pode conduzir ao diagnóstico precoce de desordens desse órgão, no entanto, a análise da imagem é subjetiva, pois depende do examinador. Sendo assim, instituir valores aos diferentes tons da escala de cinza possibilita a determinação quantitativa do padrão de normalidade para o parênquima testicular. O objetivo do trabalho é avaliar o aspecto ultra-sonográfico e analisar quantitativamente as imagens dos testículos de bovinos jovens da raça Nelore, e estabelecer parâmetros e padrões fisiológicos normais. Foram realizados exames ultrasonográficos dos testículos de 130 bovinos hígidos da raça Nelore, sendo 19 animais da fazenda 1 e 111 animais da fazenda 2. Os animais da fazenda 1 foram avaliados em cinco momentos: aos nove, 11, 13, 15 e 18 meses; ao passo que os da segunda foram avaliados aos nove, 13 e 15 meses. Com o auxílio do software "Echo Image Viewer" (EIV), foram selecionadas regiões de interesse (RI) em cada plano de varredura, assim denominadas: frontal direita (RIFD); frontal esquerda (RIFE); transversal direita (RITD); transversal esquerda (RITE). Automaticamente o software EIV calculou a média da escala de cinzas, a qual variou de 0 a 100%, sendo 0% preto (menor ecogenicidade) e 100% branco (maior ecogenicidade). O teste de Tukey foi empregado para comparar as médias das RI dentro e entre cada momento (p<0,05) utilizando-se o programa estatístico SAS (2001). A ecogenicidade testicular aumentou com o passar da idade nos animais de ambas as fazendas. Touros púberes apresentaram maior ecogenicidade testicular que os impúberes com a mesma idade. A cauda do epidídimo mostrou-se menos ecogênica que o parênquima testicular. A espessura do mediastino testicular, o volume testicular e o perímetro escrotal aumentaram com o passar da idade...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The ultrasononographic examination of testicles is a noninvasive and rapid method that, allied to clinical examination, can lead to an early diagnostic of testicles disorders, however, the image's analysis is subjective, because it depends on the professional. To institute values to different tones of gray scale aloud, then, a quantitative determination of normality's standard to testicular parenchyma. The aim of that study is to evaluate the ultrasonographic's aspect and analyse in a quantitative way the images of young Nelore bovine's testicles, and to establish normal and physiological parameters and standards. Ultrasonographic examinations of 130 healthy Nelore bovines were realized, 19 in farm 1 and 111 in farm 2. The animals of farm 1 were evaluated in five moments: at nine, 11, 13, 15 and 18 months; and the animals of farm 2 were evaluated at nine, 13 and 15 months. With the support of the software "Echo Image Viewer" (EIV), interesting areas (IA) were selected in each plane, forward denominated: right frontal (IArf), left frontal (IAlf), right transversal (IArt), left transversal (IAlt). Automatically the EIV software calculated the gray scale average, on a scale of 0 (black, the less echogenicity) to 100% (white, the most echogenicity). The Tukey test were used to compare the IA's averages in and between each moments (p<0,05) using the SAS statistic program (2001). The testicular echogenicity increased along the ages on both farm's animals. Bulls at puberty showed bigger testicular echogenicity than bulls not at puberty with the same age. The tail of epididymis showed less echogenicity than testicular's parenchyma. The thickness of mediastinum testis, testicular volume and scrotal circumference increased along the ages and positive correlations were found between testicular echogenicity, testicular volume and scrotal circunference. / Orientador: Gilson Helio Toniollo / Coorientador: Júlio Carlos Canola / Coorientadora: Maria Eugênia Zerlotti Mercadante / Banca: Francisco Guilherme Leite / Banca: Sony Dimas Bicudo / Mestre
219

[en] DISCONTINUITIES INDICATION IN METALLIC AND COMPOSITE MATERIALS: A COMPARISON OF NON-DESTRUCTIVE METHODS / [pt] INDICAÇÃO DE DESCONTINUIDADES EM MATERIAIS METÁLICOS E COMPÓSITOS: UMA COMPARAÇÃO ENTRE MÉTODOS NÃO DESTRUTIVOS

MARCIO JARDIM DE OLIVEIRA 15 April 2015 (has links)
[pt] O parque industrial nos países em desenvolvimento necessita, cada vez mais, se adaptar a uma nova filosofia de serviço em que equipamentos considerados como seguros são aqueles que podem ser inspecionadas de forma confiável. Neste contexto, ensaios não destrutivos (END) são valiosas ferramentas usadas no controle de qualidade, manutenção de componentes e, principalmente, na avaliação da integridade estrutural de tais equipamentos. Este trabalho teve como objetivo avaliar a eficiência de diferentes técnicas de END (radiação penetrante, partículas magnéticas e ultrassom) na detecção de descontinuidades simuladas em amostras de material metálico e de compósito. Os resultados experimentais mostraram que os ensaios com raios X, dentre todas as técnicas adotadas na inspeção da amostra metálica, apresentou a maior eficiência na detecção das diferentes geometrias de descontinuidades. Entretanto, nenhuma das técnicas de END possibilitou a detecção de descontinuidades na amostra do material compósito. / [en] The industrial park in developing countries need, increasingly, to adapt to a new service philosophy in which equipments considered as safe are those that can be inspected in a reliable way. In this context, non-destructive testing (NDT) are valuable tools used in quality control, maintenance of components and especially in assessing the structural integrity of such equipment. This study aimed to evaluate the efficiency of different NDT techniques (penetrating radiation, ultrasound and magnetic particles) in the detection of simulated discontinuities in samples of metallic and composite materials. The experimental results showed that the X-ray, considering all techniques adopted in the inspection of the metallic sample, showed the highest efficiency in the detection of different geometries of discontinuities. However, anynone of NDT techniques allowed the detection of discontinuities in the sample of the composite material.
220

Imagens ultrassonográficas do plexo braquial pela via axilar em cães / Ultrasonographic images of the axillary brachial plexus in dogs

Silva, Luciano Cacciari Baruffaldi Almeida da 22 December 2016 (has links)
O uso da ultrassonografia na anestesia regional teve um crescimento vertiginoso nos últimos anos, devido ao grande progresso na resolução das imagens ultrassonográficas, permitindo a visibilização não só de vasos, mas de raízes nervosas e nervos periféricos. O objetivo do presente trabalho consistiu na avaliação ultrassonográfica do plexo braquial pela via axilar, bem como a identificação dos nervos em relação a artéria axilar. Foram utilizados 50 animais da espécie canina, sem distinção de raça, sexo e idade. Em todos os animais administrou-se propofol (3 mg/kg) através de um acesso venoso pré-instalado. Os animais foram mantidos sonolentos, porém facilmente despertáveis durante todo o procedimento. Após posicionamento do animal e iniciada a avaliação ultrassonográfica com a identificação das estruturas vasculares e nervosas, foi introduzida uma agulha eletricamente isolada guiada por estimulador de nervo periférico, obtendo-se, assim, resposta motora adequada para cada nervo visualizado por meio de uma corrente estimuladora de 0,5 mA. O exame teve como objetivo identificar a artéria axilar e os nervos radial, mediano e ulnar, e anotar suas posições. Para relacionar os nervos à artéria axilar, a região a ser estudada foi dividida em quatro setores. Em todos os pacientes estudados foram identificados os nervos: mediano localizado na região craniolateral (setor 4) em 8% dos pacientes e na região craniomedial (setor 1) em 92%; nervo radial na região craniomedial (setor 1) em 2% dos pacientes, caudomedial (setor 2) em 92% e caudolateral (setor 3) em 6%; nervo ulnar encontrado na região craniolateral (setor 4) em 2% dos animais e na região craniomedial (setor 1) em 98%. Diante dos resultados, conclui-se que a artéria axilar, na abordagem estudada, facilita a identificação e posicionamento dos nervos com o auxílio do estimulador de nervos periféricos e da ultrassonografia. / The use of ultrasonography in regional anesthesia has grown rapidly in recent years, due to the great progress in the resolution of ultrasound images, allowing the visualization not only of vessels, but of nerve roots and peripheral nerves. The objective of the present study consisted in the ultrasonography evaluation of the brachial plexus by the axillary way, as well as the identification of the nerves in relation to the axillary artery. Fifty animals of the canine species were used, without distinction of race, sex and age. Propofol (3 mg/kg) was given in all animals via pre-installed venous access. The animals were kept drowsy but easily aroused throughout the procedure. After the positioning of the animal and the ultrasound evaluation with the identification of the vascular and nervous structures, an electrically isolated needle guided by a peripheral nerve stimulator was introduced, thus obtaining adequate motor response for each nerve visualized through a stimulating current of 0.5 mA. The objective of the test was to identify the axillary artery and the radial, median and ulnar nerves, and note their positions. To relate the nerves to the axillary artery, the region to be studied was divided into four sectors. In all the patients studied, nerves were identified: median located in the craniolateral region (sector 4) in 8% of patients and in the craniomedial region (sector 1) in 92%; radial nerve in the craniomedial region (sector 1) in 2% of patients, caudomedial (sector 2) in 92% and caudolateral (sector 3) in 6%; ulnar nerve found in the craniolateral region (sector 4) in 2% of the animals and in the craniomedial region (sector 1) in 98%. In view of the results, it was concluded that the axillary artery, in the approach studied, facilitates the identification and positioning of the nerves with the aid of the peripheral nerve stimulator and the ultrasonography.

Page generated in 0.0356 seconds