• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • 28
  • 17
  • 11
  • 8
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 137
  • 71
  • 44
  • 24
  • 24
  • 23
  • 20
  • 20
  • 16
  • 16
  • 14
  • 14
  • 13
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Design and modelling of passive UHF RFID tags for energy efficient liquid level detection applications : a study of various techniques in the design, modelling, optimisation and deployment of RFID reader and passive UHF RFID tags to achieve effective performance for liquid sensing applications

Atojoko, Achimugu A. January 2016 (has links)
Sewer and oil pipeline spillage issues have become major causes of pollution in urban and rural areas usually caused by blockages in the water storage and drainage system, and oil spillage of underground oil pipelines. An effective way of avoiding this problem will be by deploying some mechanism to monitor these installations at each point in time and reporting unusual liquid activity to the relevant authorities for prompt action to avoid a flooding or spillage occurrence. This research work presents a low cost energy efficient liquid level monitoring technique using Radio Frequency Identification Technology. Passive UHF RFID tags have been designed, modelled and optimized. A simple rectangular tag, the P-shaped tag and S-shaped tag with UHF band frequency of operation (850-950 MHz) has been designed and modelled. Detailed parametric analysis of the rectangular tag is made and the optimised design results analysed and presented in HFSS and Matlab. The optimised rectangular tag designs are then deployed as level sensors in a gully pot. Identical tags were deployed to detect 4 distinct levels in alternate positions and a few inches in seperation distance within the gully pot height (Low, Mid, High and Ultra high). The radiation characteristic of tag sensors in deployment as modelled on HFSS is observed to show consistent performance with application requirements. An in-manhole chamber antenna for an underground communication system is analysed, designed, deployed and measured. The antenna covers dual-band impedance bandwidths (i.e. 824 to 960 MHz, and 1710 to 2170 MHz). The results show that the antenna prototype exhibits sufficient impedance bandwidth, suitable radiation characteristics, and adequate gains for the required underground wireless sensor applications. Finally, a Linearly Shifted Quadrifilar Helical Antenna (LSQHA) designed using Genetic Algorithm optimisation technique for adoption as an RFID reader antenna is proposed and investigated. The new antenna confirms coverage of the RFID bandwidth 860-960 MHz with acceptable power gain of 13.1 dBi.
112

Efficient domain decomposition methods for electromagnetic modeling of scattering from forest environments / Méthodes de décomposition de domaine pour la modélisation électromagnétique de la diffusion par la forêt

Fenni, Ines 23 October 2014 (has links)
Cette thèse porte sur la modélisation et l’analyse de la propagation électromagnétique dans un milieu forestier dans les bandes VHF et UHF. L’objectif principal est le développement d’un modèle numérique "full-wave" tridimensionnel de diffusion par la forêt permettant de caractériser l’interaction d’une onde électromagnétique avec un milieu forestier. Un tel modèle s’avère, actuellement, un outil indispensable à l’analyse des mesures radar pour l’étude des paramètres caractéristiques de la forêt tels que la biomasse forestière, la hauteur des arbres et leur densité. La complexité numérique de ce modèle a limité son domaine d’application à de petites parcelles de forêt et aux basses fréquences. Pour pouvoir traiter de larges zones forestières tout en montant en fréquence, et s’approcher ainsi des besoins et exigences des utilisateurs potentiels de notre modèle, nous avons intégré à ce modèle une méthode numérique efficace dédiée à l’analyse de larges problèmes électromagnétiques. La méthode en question,connue sous le nom de Characteristic Basis Function Method (CBFM) était récemment développée dans le laboratoire de Communication et Electromagnétisme de l’université PennState dirigé par le Professeur Mittra. Après une optimisation et une adaptation au problème d’intérêt, la CBFM réalise d’excellentes performances et nous permet une diminution considérable du temps de calcul et des besoins en espace mémoire sans pour autant dégrader la qualité des résultats obtenus ou altérer la fidélité du modèle à la réalité du problème électromagnétique traité. / A 3-D full-wave model, based on the integral representation of the electric field and dedicatedto the analysis of bi-static scattering mechanisms by a forest in the VHF and UHF bands wasefficiently enhanced. In order to overcome the limitation of a previous 3D model to small simulationsscenes and low frequencies, we have developed, during this research work, a new model using basis functionsadapted to the problem of interest, in the context of the Characteristic Basis Function Method(CBFM) and we investigated the suitability of this direct method for computing the electromagneticfields inside and outside three-dimensional dielectric objects representing the tree trunks and branches.The CBFM has shown great performances, when applied to the forest scattering modeling, both interms of CPU time and memory resources needed. Once properly set, the CBFM-E is so efficient thatit is able to treat in few minutes electromagnetic problems totally intractable with the classical MoM.Consequently, we have developed a powerful 3D forest electromagnetic scattering tool which allows ustoday to compute large forest electromagnetic problems in few minutes without worrying about theaccuracy of the solution. On the other hand, we have demonstrated the efficiency and accuracy of theCBFM-E when applied to 3D dielectric objects in the context of the electric volumetric integral equation,and have consolidated thus its leading position in the computational electromagnetics, especiallyagainst the iterative solvers based numerical methods.
113

Quantitative MRI : towards fast and reliable T₁, T₂ and proton density mapping at ultra-high field / IRM de quantification : vers des cartographies T₁, T₂, DP rapides et fiables à très hauts champs magnétiques chez l’homme

Leroi, Lisa 23 November 2018 (has links)
L’IRM quantitative recouvre l’ensemble des méthodes permettant de mesurer des paramètres physiques accessibles en Résonance Magnétique Nucléaire. Elle offre un bénéfice par rapport à l’imagerie en pondération classiquement utilisée, notamment pour la détection, la caractérisation physiopathologique mais aussi pour le suivi thérapeutique des pathologies. Malgré ce potentiel avéré connu de longue date, ces méthodes restent peu utilisées dans la routine clinique. La raison principale est la longueur des acquisitions par rapport à l’approche classique. Les paramètres physiques que nous souhaitons étudier plus particulièrement sont le temps de relaxation longitudinal (T₁), transversal (T₂), le coefficient de diffusion apparent (ADC), et la densité de protons (DP). Malgré la possibilité d’atteindre une meilleure qualité d’images, ces cartographies in vivo sont quasiment inexistantes dans la littérature au-delà de 3T car leur implémentation nécessite de surmonter un certain nombre de limites spécifiques aux IRM ultra-haut champs (UHF). Au travers de ce projet de thèse, une méthode d’imagerie quantitative basée sur les états de configurations (QuICS) a été implémentée, pour déterminer ces paramètres quantitatifs de façon simultanée sous fortes contraintes propres aux UHF. L’approche a été optimisée dans le but d’obtenir des cartographies fiables et rapides. Le potentiel de la méthode a été démontré dans un premier temps in vitro sur un noyau tel que le sodium démontrant des propriétés complexes à cartographier. Puis dans un second temps, des acquisitions ont été réalisées sur proton, in vivo, en un temps d’acquisition compatible avec une utilisation en routine clinique à 7T. L’application d’une telle méthode d’IRM quantitative à UHF sur des populations permettra d’ouvrir de nouvelles voies d’études pour le futur. / Quantitative MRI refers to methods able to measure different physical parameters accessible in Nuclear Magnetic Resonance. It offers benefits compared to weighting imaging commonly used, for the detection, the pathophysiological characterization but also for the therapeutic follow-up of pathologies for example. Despite this long-established potential, these methods remain little used in clinical routine. The main reason is the long acquisition time compared to the classical approach. The physical parameters that we will study more particularly are the longitudinal (T₁), transverse (T₂) relaxation time, the apparent diffusion coefficient (ADC), and the proton density (DP). Despite the possibility to achieve a better image quality, these in vivo mappings are virtually non-existent in the literature beyond 3T because their implementation requires overcom-ing a number of specific ultra-high-field (UHF) MRI limits. Through this thesis project, a Quantitative Imaging method using Configuration States (QuICS) was implemented under strong UHF constraints, to determine these parameters simultaneously. The technique has been optimized to obtain fast and reliable maps. The potential of the method was first demon-strated in vitro on a nucleus such as sodium, exhibiting complex properties. As a second step, acquisitions were performed in proton, in vivo, in an clinically-relevant acquisition time, compatible with a routine use at 7T for population imaging. The application of such a method of quantitative MRI to UHF will open new research possibilities for the future.
114

Anténa pro impulzní širokopásmový signál / Antenna for broadband impulse signal

Smutný, Martin January 2015 (has links)
The thesis describes retrievals of broadband antennas for VHF and UHF. It focuses on a compact antenna, potentially suitable for detecting electromagnetic impulses generated by electrical discharges in the dielectric oil in power transformers. This pulse signals are very steep with hundreds pico seconds rising edge. The thesis presents basic characteristics of antennas and selects those which have a major influence on the possibility of using the antenna in selected application. The appropriate antena is selected and proposal its geometrical parameters is discussed. The geometry of the selected antenna is designed for working bandwidth from about 200 MHz to about 1000 MHz. The newly designed double discon antenna is simulated and dimensions are optimized. Antenna is made and key characteristics of the antenna important for evaluate the ability of detecting the above-identified pulsed signals is measured. Antenna is compared with gain and characteristic of monocone antenna. Acquired knowledge and measured data are evaluated.
115

RFID inventarizační systém / RFID Inventory System

Šindelka, Jiří January 2007 (has links)
This project deals with a survey of inventory system and accounting property. The purpose of the project is to study the SAP system, IS Apollo,  the database platform Oracle 10g, the RFID technology and to make a marketing research of a device for the chip EPCglobal UHF Gen2. On base marketing research propose and implement RFID inventory. At implementation target will be collective reading RFID tags. Further I will implement application simulating evidence systems and I will design data transmission to those application that will be also used at transmission data to the IS Apolla. I decided to implement the inventorying in the development environment Microsoft Visual Studio 2005 Standard Edition C#. Application simulated accounting property and data transmission I decide to implement in the development environment Borland Delphi 7.
116

Design and Modelling of Passive UHF RFID Tags for Energy Efficient Liquid Level Detection Applications. A study of various techniques in the design, modelling, optimisation and deployment of RFID reader and passive UHF RFID tags to achieve effective performance for liquid sensing applications

Atojoko, Achimugu A. January 2016 (has links)
Sewer and oil pipeline spillage issues have become major causes of pollution in urban and rural areas usually caused by blockages in the water storage and drainage system, and oil spillage of underground oil pipelines. An effective way of avoiding this problem will be by deploying some mechanism to monitor these installations at each point in time and reporting unusual liquid activity to the relevant authorities for prompt action to avoid a flooding or spillage occurrence. This research work presents a low cost energy efficient liquid level monitoring technique using Radio Frequency Identification Technology. Passive UHF RFID tags have been designed, modelled and optimized. A simple rectangular tag, the P-shaped tag and S-shaped tag with UHF band frequency of operation (850-950 MHz) has been designed and modelled. Detailed parametric analysis of the rectangular tag is made and the optimised design results analysed and presented in HFSS and Matlab. The optimised rectangular tag designs are then deployed as level sensors in a gully pot. Identical tags were deployed to detect 4 distinct levels in alternate positions and a few inches in seperation distance within the gully pot height (Low, Mid, High and Ultra high). The radiation characteristic of tag sensors in deployment as modelled on HFSS is observed to show consistent performance with application requirements. An in-manhole chamber antenna for an underground communication system is analysed, designed, deployed and measured. The antenna covers dual-band impedance bandwidths (i.e. 824 to 960 MHz, and 1710 to 2170 MHz). The results show that the antenna prototype exhibits sufficient impedance bandwidth, suitable radiation characteristics, and adequate gains for the required underground wireless sensor applications. Finally, a Linearly Shifted Quadrifilar Helical Antenna (LSQHA) designed using Genetic Algorithm optimisation technique for adoption as an RFID reader antenna is proposed and investigated. The new antenna confirms coverage of the RFID bandwidth 860-960 MHz with acceptable power gain of 13.1 dBi. / Petroleum Technology Development Fund (PTDF) and National Space Research and Development Agency (NASRDA).
117

Überschlagsverhalten von Gas-Feststoff-Isoliersystemen unter Gleichspannungsbelastung

Hering, Maria 28 April 2016 (has links) (PDF)
Gasisolierte Systeme im Gleichspannungsbetrieb vereinen für Anwendungen moderner Energieübertragung die Forderungen nach kleinräumigen Anlagen und verlustarmem Energietransport über große Entfernungen. Für einen zuverlässigen und sicheren Betrieb muss das Verhalten der eingesetzten Gas-Feststoff-Isolierung im technologischen System bis an die Grenzen des Isolationsvermögens bekannt sein. Gegenstand der vorliegenden Arbeit ist deshalb das Überschlagsverhalten von Gas-Feststoff-Isoliersystemen unter Gleichspannungsbelastung. Dabei stehen zwei wesentliche Einflussfaktoren im Vordergrund: die Temperatur, motiviert durch reale Stromwärmeverluste, und eine feste Störstelle auf der Gas-Feststoff-Grenzfläche, motiviert durch in der Praxis nicht völlig auszuschließende, metallische Partikel. Die Effekte dieser beiden Parameter auf die Feldverteilung, die Oberflächen- und Raumladungsbildung sowie das Isolationsvermögen bei Gleichspannung werden zunächst in zwei Versuchsanordnungen separat experimentell untersucht. Anschließend wird deren Zusammenwirken und gegenseitige Beeinflussung im Gesamtsystem analysiert. Die betriebsbedingte Erwärmung der Leiter gasisolierter Systeme führt zu einer inhomogenen Temperaturverteilung, die sich auf die Eigenschaften der Isolierstoffe Gas und Epoxidharz auswirkt. Die von der Temperatur abhängige Leitfähigkeit der Feststoffisolatoren führt zu einer temperaturabhängigen Feldverteilung, bei der sich der Ort der Höchstfeldstärke verschiebt. Dabei kann sich der Absolutwert der Höchstfeldstärke erhöhen und somit das Isolationsvermögen verringern. Gleichzeitig weist das Isoliergas nahe des erwärmten Leiters lokal eine geringere Dichte und damit eine geringere dielektrische Festigkeit auf. Die thermisch bedingte Minderung des Isolationsvermögens bei Gleichspannung beträgt in der untersuchten Anordnung (25 ... 35) %. In den schwach inhomogenen Feldern gasisolierter Anlagen erweisen sich metallische Partikel auf Isolatoren ab drei Millimetern Länge als besonders kritisch. Bei einem Gasdruck unterhalb von 0,3 MPa setzen an den Partikelspitzen zum Teil bereits ab 50 % der Durchschlagsspannung ohne Partikel Teilentladungen ein, sodass die Koronastabilisierung zu einer vergleichsweise hohen Überschlagsspannung führt. Durch diese stabilen Glimmentladungen kann die Störstelle bei Gleichspannung durch die üblichen Detektionsverfahren jedoch nicht zweifelsfrei nachgewiesen werden. Oberhalb von 0,3 MPa treten vor dem Überschlag keine Teilentladungen auf. Aufgrund der fehlenden Koronastabilisierung kann die Isolationsfestigkeit durch einen erhöhten Gasdruck nicht oder nur stark unterproportional gesteigert werden. Die mit der Modellanordnung gewonnenen Erkenntnisse sind nachweislich auf Isolatoren kommerzieller Anlagen übertragbar. Das in der vorliegenden Arbeit untersuchte Überschlagsverhalten von Gas-Feststoff-Isoliersystemen unter Gleichspannungsbelastung wird maßgeblich durch die Temperaturverteilung und durch feste Störstellen auf der Grenzfläche beeinflusst. Oberflächen- und Raumladungen verändern das üblicherweise ohmsch-kapazitiv beschriebene Verhalten des Isolierstoffsystems bei Gleich- und Mischspannungsbelastung. Der Einfluss zusätzlicher Ladungsträger auf die stark temperaturabhängige Feldumbildung demonstriert, dass das Isoliergas in diesem Fall mit teilchendichte- und feldstärkeabhängigen Drift- und Diffusionsprozessen zur Modellierung des transienten Verhaltens von Gleichspannungssystemen berücksichtigt werden muss. Die Untersuchung des Systemverhaltens an den Grenzen des Isolationsvermögens ist wichtiger Bestandteil bei der Entwicklung innovativer Technologien der modernen Energieübertragung bei steigender Übertragungsleistung. / DC operated gas-insulated systems combine the demand for space saving installations and lowloss energy transport over long distances for applications of recent energy transmission. In order to ensure a reliable and safe operation, the behaviour of the gas-solid insulation, which is used in the technological system, has to be known up to the limits of the insulation properties. Hence, this thesis deals with the flashover behaviour of gas-solid insulation systems under DC voltage stress. Thereby, it focuses on two main influence factors: the temperature, due to real current heat losses, and an adhesive defect on the gas-solid interface, due to metallic particles that cannot be fully excluded in practice. Firstly, it is investigated experimentally in two test arrangements, how each parameter separately affects the electrical field distribution, the surface and volume charge accumulation and the insulation performance under DC voltage stress. Following that, their interaction and mutual influence is analysed in the whole system. Due to operating currents, the heating of the conductors in gas-insulated systems causes an inhomogeneous temperature distribution, that affects the properties of the insulating materials gas and epoxy resin. The temperature-dependent conductivity of the solid insulators leads to a temperature-dependent field distribution. Thereby, the location of the highest field strength is shifted. Since the absolute value of the highest field strength can increase, the insulation performance can decrease. Simultaneously, the insulating gas close to the heated conductor locally has a lower gas density and therefore a lower dielectric strength. The thermal related reduction of the insulation performance under DC voltage stress amounts to (25 ... 35) % in the investigated arrangement. Metallic particles, with a length of more than three millimetres and adhering on spacers, turn out to be particularly critical in the weakly inhomogeneous field of gas-insulated systems. At pressures below 0,3 MPa, partial discharges at the particle tips partly ignite already at 50 %of the breakdown voltage without a particle. The corona stabilisation leads to a relatively high flashover voltage. However, due to these stable glow discharges under DC voltage stress, the defect can not be unequivocally proven by usual detection methods. Above 0,3 MPa, no partial discharges occur before the flashover. Due to the missing corona stabilisation, with a higher gas pressure, the insulation strength is not or only disproportionately low increasing. The findings gained with the model arrangement are evidently applicable to spacers of commercial installations. The flashover behaviour of gas-solid insulation systems under DC voltage stress, examined in this thesis, is influenced significantly by the temperature distribution and adhesive particles on the interface. Surface and volume charges change the generally resistive-capacitive described behaviour of the insulation system under DC and superimposed voltage stress. The influence of additional charge carriers on the strongly temperature-dependent field transition demonstrates, that in this case, the insulating gas with its drift and diffusion processes, depending on the particle density and the field strength, has to be considered, when modelling the transient behaviour of DC operated systems. Investigating the system behaviour to the limits of the insulation properties is a crucial element of developing innovative technologies of the modern energy transmission at increasing transmissions powers.
118

Caractérisation des décharges partielles et identification des défauts dans les PSEM sous haute tension continue / Characterization of Partial Discharges and Defect Identification in High-Voltage Direct Current GIS

Ouss, Etienne 24 September 2018 (has links)
Cette thèse s’inscrit dans le contexte de la surveillance des postes sous enveloppe métallique (PSEM) en courant continu (DC). La disponibilité de ces équipements étant primordiale pour leurs utilisateurs, il est nécessaire de disposer d’un outil de surveillance (monitoring) permettant de prévenir toute défaillance. Cet outil doit être capable de détecter et d’identifier les défauts présents, afin d’apporter une réponse adaptée. Depuis de nombreuses années, le monitoring des PSEM en AC est réalisé grâce à la mesure des décharges partielles (DP). Malheureusement, les connaissances des DP dans les PSEM en DC sont encore lacunaires, et les techniques d’identification des défauts sont intrinsèquement liées à l’environnement AC. De nouvelles techniques sont donc nécessaires en DC.Ce travail de thèse avait pour but de caractériser les décharges partielles dans les postes sous enveloppe métallique en tension continue, et de mettre en place une solution de reconnaissance automatique des défauts. Pour cela, un banc de mesure des décharges partielles a d’abord été mis en place. Afin de garantir la pertinence des résultats pour des systèmes industriels, les travaux ont été réalisés dans une section de PSEM sous tension continue. Le comportement des DP a été étudié pour deux types de défauts : des pointes sur le conducteur haute-tension et des particules libres métalliques. La caractérisation a porté sur l’influence de plusieurs paramètres : la nature et la pression du gaz, le niveau et la polarité de la tension. La mesure des DP a d’abord été réalisée en conformité avec la norme IEC 60270, permettant ainsi d’évaluer la pertinence de cette méthode pour les applications DC. La caractérisation a été complétée grâce à d’autres chaînes de mesure : une mesure de courant stationnaire, une mesure de courant haute-fréquence, une mesure de lumière, et une mesure des ondes ultra-haute fréquence (UHF). Le travail sur l’identification des défauts a d’abord consisté à construire une signature pertinente à partir des mesures de DP, puis à constituer une base de données, et enfin à implémenter un algorithme de reconnaissance automatique.Ces travaux ont montré que la méthode conventionnelle de mesure des DP présente certaines limites pour la détection des décharges partielles en DC, notamment pour les décharges couronne. Elle a tout de même permis de faire une bonne partie du travail de caractérisation. Les résultats obtenus avec les autres chaînes de mesure utilisées ont permis d’expliquer les lacunes de la méthode conventionnelle. Ils ont également permis un véritable apport pour la caractérisation des DP engendrées par des défauts de type pointe et particule. Enfin, une classification automatique efficace des défauts a été mise en place. Elle s’appuie sur le diagramme q(Δt) issu des données de la mesure conventionnelle des décharges partielles et sur un algorithme de réseau de neurones. / The framework of this thesis is the monitoring of High-Voltage, Direct Current (HVDC) Gas-Insulated Substations (GIS). The availability of these equipment is crucial for electrical networks operators. That is why they need a preventive diagnosis tool. The solution must be able to detect and identify the insulation defects, so that an appropriate maintenance can be planned. The last 40 years have seen Partial Discharges (PD) measurement become a classic monitoring tool for AC GIS. Unfortunately, there is a lack of scientific information about PD in HVDC GIS, and the known defect identification techniques are very specific to the AC environment. New techniques are thus needed in DC.This thesis aimed to characterize partial discharges in DC gas-insulated substations, and to develop an automatic defect identification tool. The first step of this work was the development of a partial discharge measuring bench. The complete study has been performed in a GIS section, so that the results can be directly applied to industrial equipment. Two kinds of defect have been investigated: protrusions on the high-voltage conductor, and free metallic particles. The influence of parameters such as gas nature and pressure, voltage level and polarity has been evaluated. First, PD have been measured in conformity with the IEC 60270 standard, and the relevance of this method in a DC environment has been evaluated. Then, other measuring chains have been used to improve the characterization of partial discharges: a steady-state current measurement, a high-frequency current measurement, a light measurement and a measurement of Ultra-High Frequency (UHF) waves. Finally, a relevant signature for defect identification has been designed and extracted from DP recordings. A database has been constituted, and an automated recognition algorithm has been implemented.The results show that the conventional PD measurement technique is not fully adapted to partial discharges detection in DC, corona discharges being the most problematic situation. Nevertheless, this method has brought enough information to start the characterization of PD. The limitations of the conventional method have been explained thanks to the results of the other measurements. These other experimental results have led to an actual improvement of the characterization of protrusion and particle-generated partial discharges. An effective automated defect classification solution has been implemented. The signature is derived from the q(Δt) diagram that has been extracted from the data obtained with the partial discharge conventional measurement. The identification algorithm has a neural network structure.
119

Analyse et exploitation des non linéarités dans les systèmes RFID UHF passifs / Analysis and exploitation of non-linearities in passive RFID UHF systems

Andia Vera, Gianfranco 20 November 2014 (has links)
Avec l'explosion de l'Internet des Objets (IoT), de nouveaux dispositifs permettant de tagguer les objets sont nécessaires afin de permettre non seulement leur identification mais aussi d'assurer des communications fiables et de nouvelles fonctionnalités comme la détection, la localisation ou la capture d'informations. Cette tendance s'appuie sur la technologie bien établie qu'est la radiofréquence par identification (RFID) et donc l'utilisation d'étiquettes (ou tags) faibles coûts et télé-alimentés. Dans ce contexte, de nombreux travaux au niveau de la couche d'application se tournent vers la mise au point de traitements logiciels complémentaires visant à produire de nouveaux types d'information. D'autres travaux visent à améliorer la couche physique avec l'objectif de miniaturiser encore le tag mais aussi de le doter de nouvelles capacités. Jusqu'à présent, il n'existe quasiment pas de travaux concernant la transmission du signal et aucun sur l'exploitation du comportement non-linéaire des puces RFID. Cette thèse vise à étudier les phénomènes non-linéaires produits lors d'une communication RFID.Dans la première partie, deux plateformes de mesure et de caractérisation spécifiques ont été développées : la première vise à observer les signaux au cours d'une communication RFID, et alors caractériser et analyser les effets liés aux phénomènes non linéaires ; la seconde permet d'effectuer différentes mesures directement sur les puces et les caractériser en termes d'impédance, production d'harmoniques et sensibilité. Ces plateformes ont permis : 1) de mettre en évidence que les fréquences harmoniques sont porteuses d'informations qui peuvent être exploitées et même offrir de nouvelles fonctionnalités ; 2) d'obtenir de nombreuses informations sur les propriétés des puces et d'en établir un modèle électrique précis ; 3) de déterminer des critères permettant d'évaluer la performance des tags dans le contexte étudié.Dans la deuxième partie, plusieurs nouveaux tags RFID ont été conçus, fabriqués, mesurés et évalués. Ces nouveaux tags fonctionnent non seulement dans la bande UHF mais aussi sont adaptés à la troisième harmonique dans la bande des microondes. Une méthodologie et des lignes directives d'aide à la conception de ce type de tags ont été établies et s'appuient sur les deux plateformes développées afin de caractériser les différents éléments. Dans un même temps, les effets liés à la fabrication ont aussi été étudiés et des études paramétriques ont permis de mettre en évidence l'effet sur les performances de la géométrie de l'antenne et du type de puce utilisée.Dans une troisième partie, les études se sont focalisées à exploiter les effets non-linéaires des dispositifs de redressement. L'idée générale est de coupler la RFID passive avec les dispositifs de transferts de puissance et de récupération d'énergie avec pour objectifs 1) de maximiser l'efficacité de conversion RF – continu 2) et d'augmenter la distance de lecture des tags passifs. Plusieurs prototypes ont été réalisés et leurs performances ont été démontrées.L'ensemble de ces travaux a mis en évidence un nouveau concept de communication RFID exploitant les non-linéarités générées par les puces RFID. Ce concept ouvre la voie à de nouvelles applications. et a fait l'objet d'une demande de brevet international. / Powered by the exploding popularity of the Internet-of-Things (IoT), the demand for tagged devices with labels capable to ensure a reliable communication with added functions beyond the identification, such as sensing, location, health-care, among others, is growing rapidly. Certainly this growing is headed by the well-established Radio Frequency Identification (RFID) technology, and the use of wireless low-cost self-powered tags, in other words passive RFID tags, is the most widespread used alternative. In the constant evolution on this field, usually new software treatments are offered at the application layer with the objective to processing data to produce some new information. Further works aimed at improving the physical layer around the tag antenna miniaturization and matching techniques. So far, little or no work had been done on the exploitation of the communication channel, and certainly none has been done on the exploitation of the non-linear behavior of RFID chips.After presenting the RFID technology and phenomena produced by Radio Frequency (RF) non-linear devices, and leaning in some nearby works on the field, the core of this thesis starts by exposing two characterization platforms for the evaluation of non-linear phenomena presented during the reader-tag communication. One is specialized in radiating measurements considering the whole tag (antenna and chip) under test. The other is specialized in conducted measurements directly over RFID chips, allowing performing different parametric studies (power dependency, impedance, harmonic production, sensitivity). The characterization results show that harmonic signals generated from the passive RFID chip carry information.By exploiting the characterization results and to verify the hypothesis of exploitation of non-linearities in RFID, i.e. the use of harmonic signals, the research is pursued by designing, fabricating, and measuring four different configurations of RFID tags. The new RFID tags operate at the fundamental frequency in the UHF band and at its $3^{rd}$ harmonic in the microwave band. Antenna design policies, fabrication details, and parametric studies on the performance of the new prototypes are presented. The parametric study takes special care in the antenna structure, kind of chip used, received power, and read range.Finally, some alternatives approaches for the exploitation of non-linear effects generated by rectifying devices are presented. Some theoretical aspects and experimental results are discussed linking the passive RFID technology to the theories of Wireless Power Transfer (WPT) and Electromagnetic Energy Harvesting (EEH). The solution takes advantage of the non-linear nature of rectifying elements in order to maximize the RF-to-DC conversion efficiency of EEH devices and increase the read range of passive RFID tags. The solution triggers on the design of a RF multi-device system. The design procedure and tests consider three non-linear phenomena: (1) the impedance power dependency, (2) the harmonic production, and (3) the rectifying dependence on the RF waveform.
120

Überschlagsverhalten von Gas-Feststoff-Isoliersystemen unter Gleichspannungsbelastung

Hering, Maria 11 March 2016 (has links)
Gasisolierte Systeme im Gleichspannungsbetrieb vereinen für Anwendungen moderner Energieübertragung die Forderungen nach kleinräumigen Anlagen und verlustarmem Energietransport über große Entfernungen. Für einen zuverlässigen und sicheren Betrieb muss das Verhalten der eingesetzten Gas-Feststoff-Isolierung im technologischen System bis an die Grenzen des Isolationsvermögens bekannt sein. Gegenstand der vorliegenden Arbeit ist deshalb das Überschlagsverhalten von Gas-Feststoff-Isoliersystemen unter Gleichspannungsbelastung. Dabei stehen zwei wesentliche Einflussfaktoren im Vordergrund: die Temperatur, motiviert durch reale Stromwärmeverluste, und eine feste Störstelle auf der Gas-Feststoff-Grenzfläche, motiviert durch in der Praxis nicht völlig auszuschließende, metallische Partikel. Die Effekte dieser beiden Parameter auf die Feldverteilung, die Oberflächen- und Raumladungsbildung sowie das Isolationsvermögen bei Gleichspannung werden zunächst in zwei Versuchsanordnungen separat experimentell untersucht. Anschließend wird deren Zusammenwirken und gegenseitige Beeinflussung im Gesamtsystem analysiert. Die betriebsbedingte Erwärmung der Leiter gasisolierter Systeme führt zu einer inhomogenen Temperaturverteilung, die sich auf die Eigenschaften der Isolierstoffe Gas und Epoxidharz auswirkt. Die von der Temperatur abhängige Leitfähigkeit der Feststoffisolatoren führt zu einer temperaturabhängigen Feldverteilung, bei der sich der Ort der Höchstfeldstärke verschiebt. Dabei kann sich der Absolutwert der Höchstfeldstärke erhöhen und somit das Isolationsvermögen verringern. Gleichzeitig weist das Isoliergas nahe des erwärmten Leiters lokal eine geringere Dichte und damit eine geringere dielektrische Festigkeit auf. Die thermisch bedingte Minderung des Isolationsvermögens bei Gleichspannung beträgt in der untersuchten Anordnung (25 ... 35) %. In den schwach inhomogenen Feldern gasisolierter Anlagen erweisen sich metallische Partikel auf Isolatoren ab drei Millimetern Länge als besonders kritisch. Bei einem Gasdruck unterhalb von 0,3 MPa setzen an den Partikelspitzen zum Teil bereits ab 50 % der Durchschlagsspannung ohne Partikel Teilentladungen ein, sodass die Koronastabilisierung zu einer vergleichsweise hohen Überschlagsspannung führt. Durch diese stabilen Glimmentladungen kann die Störstelle bei Gleichspannung durch die üblichen Detektionsverfahren jedoch nicht zweifelsfrei nachgewiesen werden. Oberhalb von 0,3 MPa treten vor dem Überschlag keine Teilentladungen auf. Aufgrund der fehlenden Koronastabilisierung kann die Isolationsfestigkeit durch einen erhöhten Gasdruck nicht oder nur stark unterproportional gesteigert werden. Die mit der Modellanordnung gewonnenen Erkenntnisse sind nachweislich auf Isolatoren kommerzieller Anlagen übertragbar. Das in der vorliegenden Arbeit untersuchte Überschlagsverhalten von Gas-Feststoff-Isoliersystemen unter Gleichspannungsbelastung wird maßgeblich durch die Temperaturverteilung und durch feste Störstellen auf der Grenzfläche beeinflusst. Oberflächen- und Raumladungen verändern das üblicherweise ohmsch-kapazitiv beschriebene Verhalten des Isolierstoffsystems bei Gleich- und Mischspannungsbelastung. Der Einfluss zusätzlicher Ladungsträger auf die stark temperaturabhängige Feldumbildung demonstriert, dass das Isoliergas in diesem Fall mit teilchendichte- und feldstärkeabhängigen Drift- und Diffusionsprozessen zur Modellierung des transienten Verhaltens von Gleichspannungssystemen berücksichtigt werden muss. Die Untersuchung des Systemverhaltens an den Grenzen des Isolationsvermögens ist wichtiger Bestandteil bei der Entwicklung innovativer Technologien der modernen Energieübertragung bei steigender Übertragungsleistung. / DC operated gas-insulated systems combine the demand for space saving installations and lowloss energy transport over long distances for applications of recent energy transmission. In order to ensure a reliable and safe operation, the behaviour of the gas-solid insulation, which is used in the technological system, has to be known up to the limits of the insulation properties. Hence, this thesis deals with the flashover behaviour of gas-solid insulation systems under DC voltage stress. Thereby, it focuses on two main influence factors: the temperature, due to real current heat losses, and an adhesive defect on the gas-solid interface, due to metallic particles that cannot be fully excluded in practice. Firstly, it is investigated experimentally in two test arrangements, how each parameter separately affects the electrical field distribution, the surface and volume charge accumulation and the insulation performance under DC voltage stress. Following that, their interaction and mutual influence is analysed in the whole system. Due to operating currents, the heating of the conductors in gas-insulated systems causes an inhomogeneous temperature distribution, that affects the properties of the insulating materials gas and epoxy resin. The temperature-dependent conductivity of the solid insulators leads to a temperature-dependent field distribution. Thereby, the location of the highest field strength is shifted. Since the absolute value of the highest field strength can increase, the insulation performance can decrease. Simultaneously, the insulating gas close to the heated conductor locally has a lower gas density and therefore a lower dielectric strength. The thermal related reduction of the insulation performance under DC voltage stress amounts to (25 ... 35) % in the investigated arrangement. Metallic particles, with a length of more than three millimetres and adhering on spacers, turn out to be particularly critical in the weakly inhomogeneous field of gas-insulated systems. At pressures below 0,3 MPa, partial discharges at the particle tips partly ignite already at 50 %of the breakdown voltage without a particle. The corona stabilisation leads to a relatively high flashover voltage. However, due to these stable glow discharges under DC voltage stress, the defect can not be unequivocally proven by usual detection methods. Above 0,3 MPa, no partial discharges occur before the flashover. Due to the missing corona stabilisation, with a higher gas pressure, the insulation strength is not or only disproportionately low increasing. The findings gained with the model arrangement are evidently applicable to spacers of commercial installations. The flashover behaviour of gas-solid insulation systems under DC voltage stress, examined in this thesis, is influenced significantly by the temperature distribution and adhesive particles on the interface. Surface and volume charges change the generally resistive-capacitive described behaviour of the insulation system under DC and superimposed voltage stress. The influence of additional charge carriers on the strongly temperature-dependent field transition demonstrates, that in this case, the insulating gas with its drift and diffusion processes, depending on the particle density and the field strength, has to be considered, when modelling the transient behaviour of DC operated systems. Investigating the system behaviour to the limits of the insulation properties is a crucial element of developing innovative technologies of the modern energy transmission at increasing transmissions powers.

Page generated in 0.0687 seconds