• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 3
  • Tagged with
  • 6
  • 6
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Imagerie quantitative du dépôt d’aérosols dans les voies aériennes du petit animal par résonance magnétique / Quantitative imaging of aerosol deposition in small animal airways using magnetic resonance imaging

Wang, Hongchen 13 March 2015 (has links)
Cette thèse s’inscrit dans le projet OxHelease (ANR-TecSan 2011) qui vise à étudier l’impact de l’inhalation de l’hélium-oxygène sur la ventilation, l’oxygénation sanguine, le dépôt d’aérosol dans l’asthme et l’emphysème. Dans ce cadre, ce travail de thèse a consisté à mettre au point des méthodes d’imagerie par résonance magnétique pour quantifier les dépôts d’aérosols chez le rat. L’administration de médicaments par voie inhalée est une approche possible pour le traitement des maladies pulmonaires comme les broncho-pneumopathies chroniques obstructives. C’est également une voie intéressante pour l’administration systémique de médicaments en raison d’un transfert potentiellement rapide dans le sang. Néanmoins, le transport et les dépôts de particules dans les poumons sont complexes et difficiles à prédire, à cause de la dépendance de nombreux paramètres, tels que le protocole d’administration, la morphologie des voies aériennes, le profil respiratoire, ou encore les propriétés aérodynamiques du gaz et des particules. Pour mieux maîtriser cette voie d’administration de médicaments, des outils d’imagerie peuvent être utilisés. L’IRM est moins conventionnelle que d’autres approches pour caractériser le poumon, mais les progrès techniques et les multiples mécanismes de contraste exploitables peuvent être mis à profit pour ce faire.Pour obtenir un signal exploitable du parenchyme pulmonaire chez le rat, une séquence IRM à temps d’écho court a été mise en place sur un système clinique à 1,5 T. Cette technique a été combinée à une administration de courte durée d’un aérosol de chélate de Gadolinium en respiration spontanée. Le mécanisme de contraste principal utilisé est la modification du temps de relaxation longitudinale induisant un rehaussement du signal et qui permet d’estimer la concentration locale avec une résolution spatiale de (0,5 mm)3 et temporelle de 7,5 min permettant également de suivre l’élimination pulmonaire au cours du temps. La sensibilité de cette approche (seuil de détection de l’ordre de 20 µM) a été déterminée et pour cela des méthodes d’analyses spécifiques globales et locales incluant des segmentations, des analyses de distributions et des statistiques ont été développées. Après validation sur des rats sains, pour lesquels un rehaussement moyen de 50%, une distribution homogène de dépôt et une dose totale relativement faible (~1 µmol/kg de poids corporel) ont été observés, cette modalité d’imagerie a pu être appliquée chez des modèles asthmatiques et emphysémateux qui ont montrés des différences significatives de certains paramètres comme l’homogénéité des dépôts ou la cinétique d’élimination. Par ailleurs, des résultats préliminaires de mise en place d’une étude multimodale, où l’IRM est comparée à la tomodensitométrie et à l’imagerie nucléaire sur les mêmes animaux a été effectuée. Enfin, dans une optique d’évaluation de la faisabilité d’approches quantitatives par IRM, un système double noyaux proton-fluor pour déterminer la sensibilité de l’imagerie de gaz et d’aérosols fluorés a été implémenté et testé sur des rats.Ces approches par IRM ouvrent des perspectives pour permettre la caractérisation in vivo des dépôts de particules inhalées dans des conditions d’administration variées et leur sensibilité suggère un transfert potentiel chez l’homme / This PhD thesis is part of the OxHelease project (ANR-TecSan 2011) that aims to study the impact of helium-oxygen inhalation on ventilation, blood oxygenation, and aerosol deposition in chronic obstructive respiratory diseases, such as asthma and emphysema. In this context, this work consisted of developing magnetic resonance imaging methods to quantify aerosol deposition in rat lung.The inhalation of pharmaceutical aerosols is an attractive approach for the treatment of lung diseases such as chronic obstructive pulmonary diseases. This is also an interesting route for the treatment of systemic disorders with the potentially fast drug transfer into circulation. However, the transport and the deposition of particles within the lungs are complex and difficult to predict, since deposition patterns depend on a number of parameters, such as administration protocols, airway geometries, inhalation patterns, and gas and aerosol aerodynamic properties. Thus, understanding drug delivery through the lungs requires imaging methods to quantify particle deposition. MRI is less conventional than other approaches for lung characterization, but the technical advances and the multiple contrast mechanisms render lung imaging more feasible.To obtain exploitable signal from the lung parenchyma of the rat, an ultra-short echo (UTE) sequence was implemented on a 1.5 T clinical system. This technique was combined with a Gadolinium-based aerosol nebulization of short duration in spontaneously breathing rats. The main contrast mechanism used here is the modification of the longitudinal relaxation time yielding signal enhancement and allowing to assess the local concentration with a spatial resolution of (0.5 mm)3 and a temporal resolution of 7.5 min enabling to quantitatively follow up lung clearance. The sensitivity of this approach (with a detection limit close to 20 µM) was determined. To do so several specific processing methods were developed for local and total lung evaluation, including segmentation, distribution analysis and statistics. After validation in the healthy rats, for which a signal enhancement of 50% on average, a homogenous distribution of deposition and a relatively low total deposited dose (~1 µmol/kg body weight) were observed, this imaging modality could be applied in asthmatic and emphysematous animal models. Significant differences were obtained such as homogeneity of deposition or clearance. Moreover, preliminary results of a multimodal study, in which MRI was compared with computed tomography and with nuclear medicine imaging in the same animals, were obtained. Finally, in order to evaluate the feasibility of other potential quantitative MRI approaches, a dual-nuclei proton/fluorine system was implemented and tested in rats for determining the sensitivity of fluorine-based gas and aerosol imaging.These MRI strategies may be applied for the in vivo characterization of particle deposition inhaled under variable administration conditions. Their sensitivity suggests a feasible translation to human.
2

Effect of ultra-short laser nanostructuring of material surfaces on the evolution of their thermoelectric properties / Effet de la nanostructuration par faisceaux laser ultra-courts sur l’évolution des propriétés thermoélectriques des matériaux

Talbi, Abderazek 11 December 2017 (has links)
Aujourd’hui, les énergies renouvelables comme l’énergie éolienne, l’énergie solaire, l’énergie hydroélectrique et la thermoélectricité jouent un rôle essentiel dans la couverture de nos besoins en énergie. Parmi ces différentes sources d’énergie, la thermoélectricité, qui permet de convertir la chaleur en électricité ou inversement, attire une grande attention grâce à son large champ d’application. Les actuelles avancées dans la recherche thermoélectrique visent l’amélioration du rendement de conversion des modules thermoélectriques, à travers l’optimisation des propriétés thermoélectriques intrinsèques des matériaux utilisés (coefficient de Seebeck, conductivité électrique et conductivité thermique). Pour cela, différentes approches ont été étudiées (dopage, nouveau alliages, nanostucturation …). Parmi ces approches, la nanostructration des matériaux a été largement étudiée pour mener à bien cet objectif. Dans ce travail de thèse, nous nous sommes intéressés à étudier l’effet de la nanostructuration de surface des matériaux (silicium mesoporeux et oxyde de titane déposé en couches minces) par faisceaux laser ultra-court (picoseconde et femtoseconde) sur l’évolution de leurs propriétés thermoélectriques. Dans un premier temps, nous nous sommes focalisés sur l’étude des différents phénomènes physiques impliqués durant l’interaction laser-matière ainsi que sur la formation des différentes nanostructures résultantes (en forme de ripples, spikes, dots et autres) en fonction de la dose laser appliquée (la fluence et le nombre de pulses). La formation de ces nanostructures a été étudiée suivant deux régimes (stationnaire et dynamique). Après l’optimisation des paramètres conduisant à la formation de ces nanostructures, la caractérisation du coefficient de Seebeck et la conductivité électrique avant et après la nanostructuration de ces matériaux a été réalisée grâce à un nouveau dispositif de mesure (ZT-meter) développé au laboratoire GREMI. Les résultats de mesures montrent une importante amélioration du coefficient de Seebeck et la conductivité électrique après la nanostrucutration. Un facteur d’augmentation de la puissance thermoélectrique a été observé pour les deux matériaux étudiés ; notamment dans le cas de couches minces d’oxyde de titane (jusqu’à 500 fois). / Today, renewable energies such as wind, solar, hydropower and thermoelectricity play an essential role to cover our energy needs. Among these different sources of energy, thermoelectricity, which offers the ability to convert a heat into electricity or vice versa, has attracted a great attention due to its wide field of potential applications. The current advances in thermoelectric research are focusing on the improvement of the conversion efficiency of thermoelectric devices through optimizing and improving the thermoelectric properties of the thermoelectric materials (Seebeck coefficient, electrical conductivity and thermal conductivity). For this, different approaches (doping, new materials, nanostucturing...) have been investigated in the literature. Among these approaches, nanostructuring of materials is the most studied in the literature in order to improve the thermoelectric properties of materials. In this thesis work, we aimed to study the effect of surface nanostructuring of materials (mesoporous silicon and titanium oxide deposited in thin film) by ultra-short laser beams (picosecond and femtosecond) on the evolution of their thermoelectric properties. First, we focused on the study of various physical phenomena involved during the laser-matter interaction that yield to the formation of very different nanostructures in form of ripples, spikes, dots and others as function of the applied laser dose (fluence and number of pulses). The formation of these nanostructures has been studied in two regimes (stationary and dynamic). After optimizing the laser parameters leading to the formation of such nanostructures, a characterization of Seebeck coefficient and the electrical conductivity before and after the nanostructuring of these materials was carried out by using a new experimental setup (ZT-meter) designed and validated in GREMI laboratory. The results of measurements showed an important improvement of Seebeck coefficient and electrical conductivity after nanostructuring. This important improvement observed with the both materials leaded to a strong increase in the thermoelectric power factor (reaching roughly 50000%).
3

Etude des propriétés du cuivre sous conditions extrêmes et hors de l'équilibre thermique / Properties of copper under extreme conditions and at thermal out-of-equilibrium

Jourdain, Noémie 25 October 2018 (has links)
Le développement des sources laser ultra-brèves permet de nos jours de porter la matière dans des états extrêmes de densité et de température. Un des régimes pouvant être atteint dans ces conditions porte le nom de « Warm Dense Matter », ou matière dense et tiède. On peut la retrouver au coeur de larges planètes comme Jupiter ou dans la fusion par confinement inertiel. Les modèles de la physique usuellement utilisés ne permettant pas de décrire correctement le comportement de la matière dans ce régime, de nombreuses recherches scientifiques, à la fois expérimentales et théoriques, sont aujourd’hui orientées vers ce sujet. Sur le long terme, il s’agirait de déterminer les propriétés macroscopiques de cet état tel que les coefficients de transports et les équations d’états. De plus, le fait de travailler avec des lasers sur des échelles de temps très courtes (dans notre cas inférieures à la picoseconde) induit des phénomènes dits « hors-équilibre thermique » durant lesquels les électrons atteignent une température importante alors que les atomes restent froids. S’en suit alors une équilibration de ces deux températures, et la plupart du temps une transition de la phase solide à la phase liquide/plasma suivant l’intensité du laser employé. Pour certains métaux, appelés métaux nobles (or, argent, cuivre), un retard à la fusion est suspecté par des simulations de dynamique moléculaire quantique, du fait d’un renforcement de la stabilité du réseau cristallin. Mon travail de thèse se propose d’étudier ce phénomène par le biais de la spectroscopie XANES, technique de spectroscopie fine d’absorption X. Potentiellement, elle permet de suivre à la fois l’évolution de la structure électronique (états électroniques près du continuum), et celle du réseau cristallin (ordre local). Il s’agit de réaliser des expériences résolues en temps, basées sur un schéma pompe-sonde : une impulsion sonde de rayons X vient caractériser l’état d’un échantillon à différents délais, après le chauffage par une impulsion laser pompe qui le porte dans le régime de la Warm Dense Matter. En parallèle, je réalise des simulations numériques basées sur la dynamique moléculaire quantique pour produire des spectres XANES, et interpréter ainsi les données en termes d’évolution ultra-rapide de la structure électronique et atomique de l’échantillon. Ce travail présentant de grands défis, sur les deux plans de l’expérience et des calculs, nous avons choisi de concentrer l’étude sur le cuivre près de ses flancs L d’absorption X (~ 932 et ~ 952 eV). / Ultrashort laser sources development enables nowadays the possibility for matter to reachboth extreme pressure and temperature (~10 000 K) conditions, or what we call "WarmDense Matter ". Working with femtosecond lasers leads to out-of-equilibrium phenomenaduring which a large amount of energy is deposited in the electrons while the lattice remainscold. We used XANES spectroscopy to follow both the ultrafast evolution of the electronicstructure and the local atomic order after the irradiation of such a laser. Moreover,we can nowadays employ Quantum Molecular Dynamics to simulate Warm Dense Matter.We computed XANES spectra for thermal out-of-equilibrium situations and inthermodynamic configurations similar to the experimental ones. The confrontation of experimental data and these calculations brings a deep understanding of the phenomena involvedand their evolutions. The present study deals with the X-ray absorption near copper L3 andL2 edges (respectively 932 and 952 eV). Calculations show a pre-edge structure in the spectra,the evolution of which gives the electronic temperature dynamics. These simulationsalso suggest that the loss of the crystalline order should give rise to the disappearance ofthe post-edge structures. Several experiments have been realized using Eclipse laser and atable-top station dedicated to time-resolved XANES measurements at CELIA laboratory.At frst, some XANES spectra have been acquired using an X-ray source produced by theirradiation of a CsI solid target. This source duration of ~2 10 ps rms { approximately thethermal equilibration timescale for copper { restrained our temporal resolution. We thenused a xenon clusters gas jet to produce an X-ray source of comparable emissivity but asignificantly shorter duration. Numerous out-of-equilibrium XANES spectrahave been acquired and for diferent excitation degrees. The excellent signal-to-noiseratio allows us to follow the evolution of the post-edge structure and deduce the associateddynamics of the loss of crystalline structure. Finally, we performed the same experimentwith an X-ray source coming from the betatron radiation at LOA laboratory. With thissource, a temporal resolution of ~ 100 fs was achieved and allows us to fully characterizethe instantaneous heating of the electrons by the laser and far-from-equilibrium states.
4

Développement d'une source laser ultra-brève, stabilisée en phase et à haut contraste, pour l'optique relativiste haute cadence

Ricci, A. 05 June 2013 (has links) (PDF)
L'interaction laser-plasma à très haute intensité (I " 1015 W/cm2) avec des impulsions ultra-courtes ( t " 100 fs) est un domaine en plein essor car il offre l'opportunité d'étudier des phénomènes physiques toujours plus brefs, regroupés sous l'appellation " science attoseconde ". L'interaction laser-plasma promet aussi l'avènement de nouvelles sources pour la génération de faisceaux de particules et de rayonnement X très énergétiques. Notre démarche se concentre sur la génération d'impulsions attosecondes sur miroir plasma à partir d'impulsions de quelques cycles optiques ( 5 fs à 800 nm), à haut taux de répétition (1 kHz) et avec un contrôle fin des paramètres laser. La génération et le contrôle temporel et spatial de l'émission d'harmoniques d'ordres élevés dans le régime non-relativiste ont récemment été démontrés par le groupe. L'objectif suivant est d'atteindre le régime relativiste, qui nécessite une intensité sur cible plus élevée. Ce travail de thèse s'inscrit donc dans la logique d'améliorer les performances de la chaine existante en termes d'énergie et de contraste temporel, tout en préservant les autres paramètres clés. Pour répondre à ces défis, l'objectif a été de mettre au point une architecture laser basée sur l'amplification à dérive de fréquence (CPA) délivrant des impulsions de 5 mJ, 5 fs à 1 kHz, avec un contraste temporel C = 1011 et une phase absolue (CEP) stabilisée à 200 mrad rms. La problématique de l'amélioration du contraste par la technique de génération de polarisation croisée (XPW) occupe une place centrale dans ce mémoire. Une étude extensive du mécanisme XPW a été menée. Elle a permis de confronter résultats expérimentaux et développements théoriques dans les régimes dits " extrêmes " tels que la génération à très haut rendement et le filtrage d'impulsions de quelques cycles optiques. En outre, un nouveau schéma de filtrage adaptable sur une large gamme d'énergie (de 100 μJ à 10 mJ) et efficace (20%) a été réalisé. La compression des impulsions d'un facteur supérieur à deux avec ce schéma a également été démontrée. La nouvelle chaine laser inclut un tel filtre dans une configuration en double CPA dont les performances finales visées sont les suivantes : 10 mJ, 20 fs, C = 1011 et CEP = 200 mrad rms. Le schéma d'étirement/compression a fait l'objet d'une étude détaillée pour permettre un étirement élevé (50 ps) tout en restant compact pour préserver la stabilité CEP. La configuration adoptée consiste en un étireur verre, un filtre acousto-optique dispersif programmable et un compresseur "grismes". Le mémoire présente enfin les perspectives de post-compression dans une fibre creuse remplie d'un gaz rare pour obtenir des impulsions de 5 mJ, 5 fs, C = 1011, CEP = 200 mrad rms à 1 kHz.
5

Adaptation of Proof of Concepts Into Quantitative NMR Methods : Clinical Application for the Characterization of Alterations Observed in the Skeletal Muscle Tissue in Neuromuscular Disorders / Des preuves de concepts à la mise en œuvre de méthodes de RMN quantitative : application clinique à la caractérisation des altérations du muscle strié squelettique dans les pathologies neuro-musculaires

Araujo, Ericky Caldas de Almeida 06 May 2014 (has links)
Actuellement, des méthodes quantitatives de résonance magnétique nucléaire (RMN) offrent des biomarqueurs qui permettent la réalisation d’études longitudinales pour le suivi de l’évolution des maladies neuromusculaires et des essais thérapeutiques de manière non-invasive. A la différence de la dégénérescence graisseuse, les processus d’inflammation/œdème/nécrose et fibrose sont des signes d’activité des maladies et leurs quantifications constitueraient ainsi de biomarqueurs parfaitement adaptés pour le suivi thérapeutique. Ce travail de thèse a consisté à mettre en place des méthodologies quantitatives plus précises et adaptées à l’étude clinique du muscle pour : (i) détecter et quantifier des sites d’activité de maladies par la cartographie T2 de l’eau ; (ii) identifier les différents processus pathophysiologiques qui sont à l’origine des altérations du T2 ; et (iii) détecter et quantifier la fibrose musculaire. Nous avons implémenté deux méthodes pour la quantification du T2 de l’eau dans le muscle. La première est basée sur une séquence d’écho de spin du type CPMG, où les signaux provenant des protons des lipides et de l’eau sont acquis simultanément et séparés à postériori par un traitement tri-exponentiel qui exploite la différence entre les T2 qui caractérisent les signaux de l’eau et de la graisse. La deuxième technique est basée sur une séquence de « partially spoiled steady state free precession (pSSFP) ». Différemment de la première technique qui nécessite un traitement assez élaboré sur des images acquises à 17 temps d’écho différents, dans la pSSFP la cartographie T2 est extraite à partir de deux séries de données 3D. L’acquisition 3D est compatible avec des techniques de sélection spectrale de l’eau, ce qui évite la contamination par les signaux des lipides. Les deux méthodes ont été validées expérimentalement chez des malades et des sujets sains et ont démontré leur capacité à détecter et quantifier des sites d’activité de maladies. Ces deux travaux font l’objet de deux publications dans des journaux scientifiques internationaux : Azzabou, de Sousa, Araujo, & Carlier, 2014. Journal of Magnetic Resonance Imaging. DOI 10.1002/jmri.24613 (in press); et de Sousa, Vignaud, Araujo, & Carlier . 2012. Magnetic Resonance in Medicine. 67:1379-1390. Malgré le fait de permettre la détection des sites d’activité de maladies, la mesure mono-exponentielle du T2 de l’eau par imagerie reste non-spécifique vis-à-vis des processus physiologiques à l’origine de l’augmentation du T2. Il est connu que la relaxation T2 du muscle squelettique n’est pas mono-exponentielle. Cela est interprété comme une conséquence de la compartimentation anatomique de l’eau tissulaire. Nous avons mis au point une méthode pour l’acquisition localisée de données CPMG. Cette technique permet l’acquisition des données dans des conditions nécessaires pour la réalisation de traitements multi-exponentiels précis. Ce travail nous a permis d’établir un modèle de compartimentation qui explique parfaitement la relaxation T2 dans le muscle. Il a fait l’objet d’un article publié dans le « Biophysical Journal » (Araujo, Fromes & Carlier 2014. New Insights on skeletal muscle tissue compartments revealed by T2 NMR relaxometry. (In press)). Les essais réalisés chez des sujets malades suggèrent un grand potentiel pour l’application de la méthode dans des études cliniques. La formation de la fibrose commence avec une accumulation excessive de tissu conjonctif intramusculaire (TCIM). Nous avons exploité la technique « Ultrashort Time-to-Echo » (UTE) pour essayer de détecter et caractériser le signal du TCIM. Dans une première étude, nous avons caractérisé in vivo une composante à T2 court (~500 µs) dans le muscle, et nous avons trouvé des indices qui suggèrent qu’elle représente le TCIM. Dans une deuxième étude, nous avons mis au point une méthodologie qui a permis d’imager cette composante à T2 court dans le muscle pour la première fois. / Current quantitative nuclear magnetic resonance (NMR) technics offer biomarkers that allow performing non-invasive longitudinal studies for the follow up of therapeutic trials in neuromuscular disorders (NMD). In contrast to fat degeneration, the mechanisms of inflammation/oedema/necrosis and fibrosis are characteristic signs of disease activity, which makes their quantification a promising source of crucial biomarkers for longitudinal studies. This thesis work consisted on the implementation of more precise quantitative NMR methods adapted to the clinical study of skeletal muscle (SKM) for : (i) detection and quantification of sites of disease activity by T2-mapping of muscle water ; (ii) investigation of the different pathophysiological mechanisms underlying T2 alterations ; and (iii) Detection and quantification of muscle fibrosis. We implemented two methods for T2 mapping of muscle water. The first one is based on a multi-spin-echo sequence du type CPMG. In this method the 1H-NMR signals from water and lipids are acquired simultaneously. The acquired data are fitted to a tri-exponential model, in which water and fat signals are separated by exploring the T2 difference between water and fat. This method allows extraction of muscle water T2-value in the presence of fat infiltration. The second method is based on a « partially spoiled steady state free precession » (pSSFP) sequence. In contrast to the first method, which demands a sophisticated post-treatment of images acquired at 17 different echo-times, with the pSSFP a T2-mapping is extracted from two 3D data sets. 3D acquisition is compatible with spectrally selective water excitation, which eliminates signal contribution from lipids. Both methods were validated experimentally on patients and healthy subjects. The results demonstrated their capacity to detect and quantify disease activity sites. This 2 works have been published in two international journals : Azzabou, de Sousa, Araujo, & Carlier, 2014. Journal of Magnetic Resonance Imaging. DOI 10.1002/jmri.24613 (in press); et de Sousa, Vignaud, Araujo, & Carlier . 2012. Magnetic Resonance in Medicine. 67:1379-1390. Although it was shown to reveal disease activity, mono-exponential T2 of muscle water is non-specific to what concerns the mechanisms underlying its alterations. It has been long known that T2 relaxation in SKM tissue is multi-exponential. This is currently accepted to reveal anatomical compartmentation of myowater. We implemented a method for localized spectroscopic CPMG acquisition. CPMG data respect echo-time sampling and signal to noise ration limits for allowing robust multiexponential analysis. This work allowed us to establish a compartmentation model that perfectly explains the multi-exponential T2 relaxation observed in SKM tissue. This work was published in the « Biophysical Journal » (Araujo, Fromes & Carlier 2014. New Insights on skeletal muscle tissue compartments revealed by T2 NMR relaxometry. (In press)). Pilot studies performed in patients show promising results and suggest potential application of the method in clinical studies. Fibrosis starts with an excessive accumulation of intramuscular connective tissue (IMCT). We have explored the « Ultrashort time to echo » (UTE) method with the aim to detect and characterize the signal from IMCT. In a first study we characterized in vivo a short T2 component (~500 µs) in SKM, and we collected evidences suggesting that this component might reflect IMCT. Then we implemented a methodology that allowed imaging this short component in SKM tissue for the first time.
6

Magnetic resonance imaging techniques for pre-clinical lung imaging / Techniques d’IRM pour l’imagerie préclinique du poumon

Bianchi, Andrea 28 March 2014 (has links)
Dans ce travail, les s´séquences Imagerie par Résonance Magnétique (IRM) radiales à temps d’écho ultra-court (UTE) sont analysées pour évaluer leur potentiel dans l’étude non-invasive de différents modèles expérimentaux de maladies pulmonaires chez la souris. Chez le petit animal, les séquences radiales UTE peuvent efficacement limiter l’impact négatif sur la qualité de l’image dû au déphasage rapide des spins causé par les nombreuses interfaces air/tissu. En plus, les séquences radiales UTE sont moins sensibles aux artefacts de mouvement par rapport aux séquences Cartésiennes classiques. En conséquence, chez le petit animal, les séquences radiales UTE peuvent permettre d’obtenir des images du poumon avec une résolution bien inférieure au millimètre avec des rapports signal/bruit importants dans le parenchyme pulmonaire, tout en travaillant en conditions physiologiques (animaux en respiration spontanée). Dans cette thèse, il sera démontré que les séquences d’IRM protonique UTE sont outils efficaces dans l’étude quantitative et non-invasive de différents marqueurs distinctifs de certaines pathologies pulmonaires d’intérêt général. Les protocoles développés serontsimples, rapides et non-invasifs, faciles à implémenter, avec une interférence minimale sur la pathologie pulmonaire étudiée et, en définitive, potentiellement applicables chez l’homme. Il sera ainsi démontré que l’emploi des agents de contraste, administrés via les voies aériennes, permet d’augmenter la sensibilité des protocoles développés. Parallèlement, dans cette thèse des protocoles suffisamment flexibles seront implémentés afin de permettre l’étude d’un agent de contraste paramagnétique générique pour des applications aux poumons. / In this work, ultra-short echo time (UTE) Magnetic Resonance Imaging (MRI) sequences are investigated as flexible tools for the noninvasive study of experimental models of lung diseases in mice. In small animals radial UTE sequences can indeed efficiently limit the negative impact on lung image quality due to the fast spin dephasing caused by the multiple air/tissue interfaces. In addition, radial UTE sequences are less sensitive to motion artifacts compared to standard Cartesian acquisitions. As a result, radial UTE acquisitions can provide lung images in small animals at sub-millimetric resolution with significant signal to noise ratio in the lung parenchyma, while working with physiological conditions (freely-breathing animals). In this thesis, UTE proton MRI sequences were shown to be efficient instruments to quantitatively investigate a number of hallmarks in longitudinal models of relevant lung diseases with minimal interference with the lung pathophysiology, employing easilyimplementable fast protocols. The synergic use of positive contrast agents, along with anadvantageous administration modality, was shown to be a valuable help in the increase of sensitivity of UTE MRI. At the same time, UTE MRI was shown to be an extremely useful and efficacious sequence for studying positive contrast agents in lungs

Page generated in 0.0449 seconds