• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 163
  • 108
  • 37
  • 7
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • Tagged with
  • 445
  • 445
  • 107
  • 99
  • 54
  • 46
  • 37
  • 29
  • 26
  • 26
  • 21
  • 21
  • 20
  • 19
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

UV index measurement and model agreement: uncertainties and limitations

Badosa i Franch, Jordi 27 September 2005 (has links)
En les últimes dècades, l'increment dels nivells de radiació solar ultraviolada (UVR) que arriba a la Terra (principalment degut a la disminució d'ozó estratosfèric) juntament amb l'augment detectat en malalties relacionades amb l'exposició a la UVR, ha portat a un gran volum d'investigacions sobre la radiació solar en aquesta banda i els seus efectes en els humans. L'índex ultraviolat (UVI), que ha estat adoptat internacionalment, va ser definit amb el propòsit d'informar al públic general sobre els riscos d'exposar el cos nu a la UVR i per tal d'enviar missatges preventius. L'UVI es va definir inicialment com el valor màxim diari. No obstant, el seu ús actual s'ha ampliat i té sentit referir-se a un valor instantani o a una evolució diària del valor d'UVI mesurat, modelitzat o predit. El valor concret d'UVI està afectat per la geometria Sol-Terra, els núvols, l'ozó, els aerosols, l'altitud i l'albedo superficial.Les mesures d'UVI d'alta qualitat són essencials com a referència i per estudiar tendències a llarg termini; es necessiten també tècniques acurades de modelització per tal d'entendre els factors que afecten la UVR, per predir l'UVI i com a control de qualitat de les mesures. És d'esperar que les mesures més acurades d'UVI s'obtinguin amb espectroradiòmetres. No obstant, com que els costs d'aquests dispositius són elevats, és més habitual trobar dades d'UVI de radiòmetres eritemàtics (de fet, la majoria de les xarxes d'UVI estan equipades amb aquest tipus de sensors). Els millors resultats en modelització s'obtenen amb models de transferència radiativa de dispersió múltiple quan es coneix bé la informació d'entrada. No obstant, habitualment no es coneix informació d'entrada, com per exemple les propietats òptiques dels aerosols, la qual cosa pot portar a importants incerteses en la modelització. Sovint, s'utilitzen models més simples per aplicacions com ara la predicció d'UVI o l'elaboració de mapes d'UVI, ja que aquests són més ràpids i requereixen menys paràmetres d'entrada.Tenint en compte aquest marc de treball, l'objectiu general d'aquest estudi és analitzar l'acord al qual es pot arribar entre la mesura i la modelització d'UVI per condicions de cel sense núvols.D'aquesta manera, en aquest estudi es presenten comparacions model-mesura per diferents tècniques de modelització, diferents opcions d'entrada i per mesures d'UVI tant de radiòmetres eritemàtics com d'espectroradiòmeters. Com a conclusió general, es pot afirmar que la comparació model-mesura és molt útil per detectar limitacions i estimar incerteses tant en les modelitzacions com en les mesures. Pel que fa a la modelització, les principals limitacions que s'han trobat és la falta de coneixement de la informació d'aerosols considerada com a entrada dels models. També, s'han trobat importants diferències entre l'ozó mesurat des de satèl·lit i des de la superfície terrestre, la qual cosa pot portar a diferències importants en l'UVI modelitzat. PTUV, una nova i simple parametrització pel càlcul ràpid d'UVI per condicions de cel serens, ha estat desenvolupada en base a càlculs de transferència radiativa. La parametrització mostra una bona execució tant respecte el model base com en comparació amb diverses mesures d'UVI. PTUV ha demostrat la seva utilitat per aplicacions particulars com ara l'estudi de l'evolució anual de l'UVI per un cert lloc (Girona) i la composició de mapes d'alta resolució de valors d'UVI típics per un territori concret (Catalunya). En relació a les mesures, es constata que és molt important saber la resposta espectral dels radiòmetres eritemàtics per tal d'evitar grans incerteses a la mesura d'UVI. Aquest instruments, si estan ben caracteritzats, mostren una bona comparació amb els espectroradiòmetres d'alta qualitat en la mesura d'UVI. Les qüestions més importants respecte les mesures són la calibració i estabilitat a llarg termini. També, s'ha observat un efecte de temperatura en el PTFE, un material utilitzat en els difusors en alguns instruments, cosa que potencialment podria tenir implicacions importants en el camp experimental.Finalment, i pel que fa a les comparacions model-mesura, el millor acord s'ha trobat quan es consideren mesures d'UVI d'espectroradiòmetres d'alta qualitat i s'usen models de transferència radiativa que consideren les millors dades disponibles pel que fa als paràmetres òptics d'ozó i aerosols i els seus canvis en el temps. D'aquesta manera, l'acord pot ser tan alt dins un 0.1º% en UVI, i típicament entre menys d'un 3%. Aquest acord es veu altament deteriorat si s'ignora la informació d'aerosols i depèn de manera important del valor d'albedo de dispersió simple dels aerosols. Altres dades d'entrada del model, com ara l'albedo superficial i els perfils d'ozó i temperatura introdueixen una incertesa menor en els resultats de modelització. / The increase in solar ultraviolet radiation (UVR) levels reaching the Earth surface during the last decades (mostly induced by the stratospheric ozone depletion), together with a detected increase in UVR-related diseases, has lead to a high volume of investigations about this band of the solar radiation and its effects on human beings.The ultraviolet Index (UVI), which is currently internationally adopted, was defined in order to disseminate information to the public about the risks of exposing the naked body to UVR and to send preventive messages. UVI was initially defined as the maximum daily value. However, the current use of this index has been widened and nowadays it makes sense to refer to an instantaneous value or to the evolution of the measured, modelled, or predicted UVI during the day. The actual value of UVI is affected by the Sun-Earth geometry, clouds, ozone, aerosols, altitude and ground albedo. High quality UVI measurements are essential as a reference and to study long-term trends; accurate modelling techniques are needed to understand the way factors affect UVR, to predict UVI, and as a quality control of the measurements. For the UVI measurement, best accuracy is expected with data from spectroradiometers. However, since the costs of these devices are expensive, data from erythemal radiometers are more commonly available (most UVI networks are equipped with this latter type of sensors). Best UVI modelling performance is found with multi-scattering radiative transfer models when the input information is well known. However, some relevant input information, such as the aerosol optical properties, is usually not available which can lead to large modelling uncertainties. More simple models are often used for applications such as UVI prediction or elaboration of UVI maps, as they are much faster and require less input parameters.Considering this framework, the general objective of this work is to analyse the agreement that can be reached between modelled and measured UVI for cloudless conditions.For this, model-measurement comparisons are presented for different modelling techniques, for several input options, and for UVI measured by both erythemal radiometers and spectroradiometers. As a general conclusion, it can be stated that the comparison of modelled vs. measured UVI is very useful to detect limitations and estimate uncertainties in both the modelling and measurements.As far as modelling is concerned, the main limitations found are the lack of knowledge in the aerosol information considered as input. Also, important differences are found between the ozone column from satellite and from ground based measurements, which lead to important differences in the modelled UVI.PTUV, a new simple parameterisation for fast UVI calculations for cloudless conditions, has been developed based on radiative transfer calculations. The parameterisation shows a good performance both with respect to the base model and to diverse UVI measurements. PTUV has demonstrated to be useful for particular applications such as to study the annual UVI variation at a particular site (Girona) and to build high resolution maps of typical UVI for a territory (Catalonia).Regarding the measurements, it is found that the use of the actual spectral response of the erythemal radiometers is very important to avoid large uncertainties in the measured UVI. If well characterised, the erythemal radiometers compare reasonably well with high quality spectroradiometers when measuring UVI. Major issues with respect to the measurements are long term calibration accuracy and stability. Also, a temperature effect in PTFE, a material used as diffuser in some instruments, has been observed, which could have potentially important implications in the experimental field. Finally, and concerning the model-measurement comparisons, the best agreement has been found when high quality spectroradiometric UVI measurements are considered and radiative transfer models are applied taking into account the best data available regarding aerosol and ozone optical parameters and their changes in time. In this case, the agreement can be as high as 0.1% in UVI, and typically less than 3%. This agreement deteriorates greatly if aerosols are ignored, and depends importantly on the aerosol single scattering albedo. Other data, such as ground albedo or the actual atmospheric temperature and ozone profiles, introduce lower uncertainty in the modelling results.
322

In-situ Monitoring of Photopolymerization Using Microrheology

Slopek, Ryan Patrick 18 July 2005 (has links)
Photopolymerization is the basis of several multi-million dollar industries including films and coating, inks, adhesives, fiber optics, and biomaterials. The fundamentals of the photopolymerization process, however, are not well understood. As a result, spatial variations of photopolymerization impose significant limitations on applications in which a high spatial resolution is required. To address these issues, microrheology was implemented to study the spatial and temporal effects of free-radical photopolymerization. In this work a photosensitive, acrylate resin was exposed to ultraviolet light, while the Brownian motion of micron sized, inert fluorescent tracer particles was tracked using optical videomicroscopy. Statistical analysis of particle motion yielded data that could then be used to extract rheological information about the embedding medium as a function of time and space, thereby relating UV exposure to the polymerization and gelation of monomeric resins. The effects of varying depth, initiator concentration, inhibitor concentration, composition of the monomer, and light intensity on the gelation process were studied. The most striking result is the measured difference in gelation time observed as a function of UV penetration depth. The observed trend was found to be independent of UV light intensity and monomer composition. The intensity results were used to test the accuracy of energy threshold model, which is used to empirically predict photo-induced polymerization. The results of this research affirm the ability of microrheology to provide the high spatial and temporal resolution necessary to accurately monitor the photopolymerization process. The experimental data provide a better understanding of the photo-induced polymerization, which could lead to expanded use and improved industrial process optimization. The use of microrheology to monitor photopolymerization can also aid in the development of predictive models and offer the ability to perform in-situ quality control of the process.
323

Solar ultraviolet radiation: monitoring, dosimetry and protection

Ho, Wing-kwok., 何永國. January 1999 (has links)
published_or_final_version / Radioisotope / Master / Master of Philosophy
324

Ultraviolet emitters grown by metalorganic chemical vapor deposition

Liu, Yuh-Shiuan 13 January 2014 (has links)
This thesis presents the development of III-nitride materials for deep-ultraviolet (DUV) light emitting devices. The goal of this research is to develop a DUV laser diode (LD) operating at room temperature. Epitaxial structures for these devices are grown by metalorganic chemical vapor deposition (MOCVD) and several material analysis techniques were employed to characterize these structures such as atomic force microscopy, electroluminescence, Hall-effect measurement, photoluminescence, secondary ion mass spectrometry, transmission electron microscopy, transmission line measurement, and X-ray diffraction. Each of these will be discussed in detail. The active regions of III-nitride based UV emitters are composed of AlxGa1-xN alloys, the bandgap of which can be tuned from 3.4 eV to 6.2 eV, which allows us to attain the desired wavelength in the DUV by engineering the molar fraction of aluminum and gallium. In order to emit photons in the DUV wavelength range (> 4.1 eV), high aluminum molar fraction AlxGa1-xN alloys are required. Since aluminum has very low ad-atom mobility on the growth surface, a very low group V to group III precursor ratio (known as V/III ratio), high growth temperature, and low growth pressure is required to form a smooth surface and subsequently abrupt heterointerfaces. The first part of this work focuses on developing high-quality multi-quantum well structures using high aluminum molar fraction ([Al] > 60%) AlxGa1-xN alloys. Optically pumped DUV lasers were demonstrated with threshold power density as low as 250 kW/cm² for the emission wavelength as short as 248.3 nm. Transverse electric (TE) -like emission dominates when the lasers were operating above threshold power density, which suggests the diode design requires the active region to be fully strained to promote better confinement of the optical mode in transverse direction. The second phase of this project is to achieve an electrically driven injection diode laser. Owing to their large bandgap, low intrinsic carrier concentration, and relatively high dopant activation energy, the nature of these high aluminum molar fraction materials are highly insulating; therefore, efficiently transport carriers into active region is one of the main challenges. Highly conducting p-type material is especially difficult to achieve because the activation energy for magnesium, a typical dopant, is relatively large and some of the acceptors are compensated by the hydrogen during the growth. Furthermore, due to the lack of a large work function material to form a p-type ohmic contact, the p-contact layer design is limited to low aluminum molar fraction material or gallium nitride. Besides the fabrication challenges, these low aluminum molar fraction materials are not transparent to the laser wavelength causing relatively high internal loss (αi). In this work, an inverse tapered p-waveguide design is employed to transport holes to active region efficiently while the graded-index separate-confinement heterostructure (GRINSCH) is employed for the active region design. Together, a multi-quantum well (MQW) ultraviolet emitter was demonstrated.
325

Relativistic theory of photoemission for magnetic materials

Woods, Matthew January 2000 (has links)
No description available.
326

Ultraviolet disinfection kinetics for potable water production.

Amos, Steve A. January 2008 (has links)
Irradiation with ultraviolet (UV) light is used for the disinfection of bacterial contaminants in the production of potable water, and in the treatment of selected wastewaters. However, efficacy of UV disinfection is limited by the combined effect of suspended solids concentration and UV absorbance. Limited published UV disinfection data are available that account for the combined effects of UV dose, suspended solids concentration and UV absorbance. This present lack of a rigorous quantitative understanding of the kinetics of UV disinfection limits process optimisation and wider application of UV treatment. The development and validation of an adequate model to describe UV disinfection kinetics presented in this thesis can therefore be justified by an increased confidence of reliability of design for UV disinfection. Using the published data of Nguyen (1999), four established model forms were assessed to account for the combined effect of suspended solids and/or soluble UV absorbing compounds, and UV dose on the efficacy of disinfection. The four model forms were: a log-linear form, Davey Linear-Arrhenius (DL-A), Square-Root (or Ratkowsky- Belehradek) and a general nth order Polynomial (nOP) form that was limited to a third order. Criteria for assessment of an adequate predictive model were established including: accuracy of predicted against observed values, percent variance accounted for (%V), and; appraisal of residuals. The DL-A model was shown to best fit the data for UV disinfection of Escherichia coli (ATCC 25922); followed by the nOP, log-linear and Square-Root forms. However, the DL-A form must be used in conjunction with a first-order chemical reaction equation, and was shown to predict poorly at high experimental values of UV dose (> 40,000 μWs cm-2). The DL-A model was not amenable to extrapolation beyond the observed UV dose range. To overcome the shortcomings of the Davey Linear-Arrhenius model synthesis of two new, non-linear model forms was undertaken. The two models were a modified exponentially damped polynomial (EDPm) and a form based on the Weibull probability distribution. The EDPm model has three terms: a rate coefficient (k), a damping coefficient (λ), and; a breakpoint dose ([dose]B). The rate coefficient governs the initial rate of disinfection prior to the onset of tailing, whilst the breakpoint is the UV dose that indicates the onset of tailing. The damping coefficient controls curvature in the survivor curve. The Weibull model has just two terms: a dimensionless scale parameter (β0), and; a shape parameter (β1). The scale parameter represents the level of disinfection in the tail of the survivor curve (as log10 N/N0), whilst the shape parameter governs the degree of curvature of the survivor data. Each model was assessed against the independent and published UV disinfection data of Nelson (2000) for treatment of faecal coliforms in a range of waste stabilisation pond effluents. Both models were found to be well suited to account for tailing in these UV disinfection data. Overall, the EDPm model gave a better fit to the data than the Weibull model form. To rigorously validate the suitability of the new EDPm and Weibull models a series of experimental trials were designed and carried out in a small-scale pilot UV disinfection unit. These trials included data determined specifically at low values of UV dose (<10,000 μWs cm-2) to fill the gap in the experimental data of Nguyen (1999). The experimental trials were carried out using a commercially available, UV disinfection unit (LC5TM from Ultraviolet Technology of Australasia Pty Ltd). Purified water contaminated with Escherichia coli (ATCC 25922) with a range of feed water flow rates (1 to 4 L min-1) was used. E. coli was selected because it is found in sewage, or water contaminated with faecal material, and is used as an indicator for the presence of enteric pathogens. E. coli should not be present in potable water. The hydrodynamics of water flow within the disinfection unit were established using digital video photography of dye trace studies with Methylene Blue. Nominal UV dose (2,700 to 44,200 μWs cm-2) was controlled by manipulating the flow rate of feed water through the UV disinfection unit (i.e. residence time), or by varying the exposed length of the control volume of the disinfection unit. The transmittance of the feed water (at 254 nm) was adjusted by the addition of either a soluble UV absorbing agent (International RoastTM instant coffee powder; 0.001 to 0.07 g L-1), or by addition of suspended matter as diatomaceous earth (Celite 503TM; 0.1 to 0.7 g L-1, with a median particle size of 23 μm). The absorbing agent (instant coffee), when in a comparable concentration, was found to produce a greater reduction in water transmission than the suspended material (Celite 503TM). It therefore contributed to a greater reduction in the initial rate of disinfection. Neither agent was found to produce a systematic reduction in the observed efficacy of disinfection however. Experimental results highlight that in the absence of soluble absorbing agents, or suspended solids, the initial rate of disinfection is higher when fewer viable bacteria are initially present. Both the new EDPm and Weibull forms gave a good fit to the experimental data. The EDPm better fitted the data on the basis of residual sum-of-squares (0.03 to 2.13 for EDPm cf. 0.16 to 4.37 for the Weibull form). These models are both of a form suitable for practical use in modelling UV disinfection data. Results of this research highlight the impact of water quality, as influenced by the combined effect of UV dose, suspended solids concentration and UV absorbance, on small-scale UV disinfection for potable water production. Importantly, results show that the concentration of soluble UV absorbing agents and suspended solids are not in themselves sufficient criteria on which to base assessment of efficacy of UV disinfection / http://proxy.library.adelaide.edu.au/login?url= http://library.adelaide.edu.au/cgi-bin/Pwebrecon.cgi?BBID=1342403 / Thesis (M.Eng.Sc.) - University of Adelaide, School of Chemical Engineering, 2008
327

Evaluation of the contribution of reflected UVR to the inner canthus' total dose

Birt, Benjamin Joseph January 2007 (has links)
Basal cell carcinoma is a form of a non-melanoma skin tumour, that commonly forms over the sun exposed regions of the head and neck. Investigation of the rate of occurrence at different sites on face and neck shows considerable variation from site to site. The inner canthus has a disproportionate number when compared to more exposed sites. The eye brow ridge, cheek bone and nose limit the field of view of the inner canthus, thus it is expected to receive less radiation than other more exposed regions. To explain the disproportionate rate, it is hypothesised that a portion of radiation incident onto the eye is reflected to the inner canthus. The aim of this thesis is to investigate the contribution that the radiation reflected off the surface of the eye makes to the overall dose on the inner canthus. The inter reflections between the eye and inner canthus were studied through the use of the ray tracing program Zemax. Zemax was used to trace rays in a non sequential mode incident onto a model eye and periorbital region. To obtain the models of the eye and periorbital region, both magnetic resonance imaging and a casting process was investigated, with the later being superior for our uses. With the model obtained, it was used in a series of three dimensional ray tracing programs. On a macroscopic scale there is a small increase in the irradiance on the inner canthus (2 % over a 1 cm2 area). Peaks of high irradiance (19 % increase in irradiance above direct irradiance) were discovered over the surface when the detector was divided into 200 mm elements. It was concluded that these increases above the direct irradiance in these small regions, increases the possibility of the occurrence of a Basal cell carcinoma. Individual facial geometry, will greatly effect the location and size of these peaks and as a result an experimental method to measure the dose distribution across the inner canthus was proposed. Initially it was planned to use polysulphone film to measure the erythemal dose on the inner canthus. Results from the modelling indicated that any measurements made had to be at a high spatial resolution. Polysulphone film was found to be inadequate for this, due to its large uncertainties. An alternative method was investigated so that a population study could be performed in future studies using visible radiation and high dynamic range images gave a simple and effective clinical assessment tool. The high dynamic range images showed hot spots in the irradiance across the inner canthus agreeing with the model. The small spots of high relative irradiance may not be the only reason for the increased rate in this region. Greater skin sensitivity and absence of sun screen use at this site are other possibilities. It is believed however that the irradiance distribution across the inner canthus on a microscopic scale goes a long way to increasing the risk for certain people.
328

On the effect of UV-irradiation on DNA replication in Escherichia coli / Meera Mary Verma

Verma, Meera Mary January 1985 (has links)
Bibliography: leaves 267-287 / xviii, 287, [ca. 40] leaves, [10] leaves of plates : ill ; 30 cm. / Title page, contents and abstract only. The complete thesis in print form is available from the University Library. / Thesis (Ph.D.)--University of Adelaide, Dept. of Biochemistry, 1985
329

Ultraviolet disinfection kinetics for potable water production.

Amos, Steve A. January 2008 (has links)
Irradiation with ultraviolet (UV) light is used for the disinfection of bacterial contaminants in the production of potable water, and in the treatment of selected wastewaters. However, efficacy of UV disinfection is limited by the combined effect of suspended solids concentration and UV absorbance. Limited published UV disinfection data are available that account for the combined effects of UV dose, suspended solids concentration and UV absorbance. This present lack of a rigorous quantitative understanding of the kinetics of UV disinfection limits process optimisation and wider application of UV treatment. The development and validation of an adequate model to describe UV disinfection kinetics presented in this thesis can therefore be justified by an increased confidence of reliability of design for UV disinfection. Using the published data of Nguyen (1999), four established model forms were assessed to account for the combined effect of suspended solids and/or soluble UV absorbing compounds, and UV dose on the efficacy of disinfection. The four model forms were: a log-linear form, Davey Linear-Arrhenius (DL-A), Square-Root (or Ratkowsky- Belehradek) and a general nth order Polynomial (nOP) form that was limited to a third order. Criteria for assessment of an adequate predictive model were established including: accuracy of predicted against observed values, percent variance accounted for (%V), and; appraisal of residuals. The DL-A model was shown to best fit the data for UV disinfection of Escherichia coli (ATCC 25922); followed by the nOP, log-linear and Square-Root forms. However, the DL-A form must be used in conjunction with a first-order chemical reaction equation, and was shown to predict poorly at high experimental values of UV dose (> 40,000 μWs cm-2). The DL-A model was not amenable to extrapolation beyond the observed UV dose range. To overcome the shortcomings of the Davey Linear-Arrhenius model synthesis of two new, non-linear model forms was undertaken. The two models were a modified exponentially damped polynomial (EDPm) and a form based on the Weibull probability distribution. The EDPm model has three terms: a rate coefficient (k), a damping coefficient (λ), and; a breakpoint dose ([dose]B). The rate coefficient governs the initial rate of disinfection prior to the onset of tailing, whilst the breakpoint is the UV dose that indicates the onset of tailing. The damping coefficient controls curvature in the survivor curve. The Weibull model has just two terms: a dimensionless scale parameter (β0), and; a shape parameter (β1). The scale parameter represents the level of disinfection in the tail of the survivor curve (as log10 N/N0), whilst the shape parameter governs the degree of curvature of the survivor data. Each model was assessed against the independent and published UV disinfection data of Nelson (2000) for treatment of faecal coliforms in a range of waste stabilisation pond effluents. Both models were found to be well suited to account for tailing in these UV disinfection data. Overall, the EDPm model gave a better fit to the data than the Weibull model form. To rigorously validate the suitability of the new EDPm and Weibull models a series of experimental trials were designed and carried out in a small-scale pilot UV disinfection unit. These trials included data determined specifically at low values of UV dose (<10,000 μWs cm-2) to fill the gap in the experimental data of Nguyen (1999). The experimental trials were carried out using a commercially available, UV disinfection unit (LC5TM from Ultraviolet Technology of Australasia Pty Ltd). Purified water contaminated with Escherichia coli (ATCC 25922) with a range of feed water flow rates (1 to 4 L min-1) was used. E. coli was selected because it is found in sewage, or water contaminated with faecal material, and is used as an indicator for the presence of enteric pathogens. E. coli should not be present in potable water. The hydrodynamics of water flow within the disinfection unit were established using digital video photography of dye trace studies with Methylene Blue. Nominal UV dose (2,700 to 44,200 μWs cm-2) was controlled by manipulating the flow rate of feed water through the UV disinfection unit (i.e. residence time), or by varying the exposed length of the control volume of the disinfection unit. The transmittance of the feed water (at 254 nm) was adjusted by the addition of either a soluble UV absorbing agent (International RoastTM instant coffee powder; 0.001 to 0.07 g L-1), or by addition of suspended matter as diatomaceous earth (Celite 503TM; 0.1 to 0.7 g L-1, with a median particle size of 23 μm). The absorbing agent (instant coffee), when in a comparable concentration, was found to produce a greater reduction in water transmission than the suspended material (Celite 503TM). It therefore contributed to a greater reduction in the initial rate of disinfection. Neither agent was found to produce a systematic reduction in the observed efficacy of disinfection however. Experimental results highlight that in the absence of soluble absorbing agents, or suspended solids, the initial rate of disinfection is higher when fewer viable bacteria are initially present. Both the new EDPm and Weibull forms gave a good fit to the experimental data. The EDPm better fitted the data on the basis of residual sum-of-squares (0.03 to 2.13 for EDPm cf. 0.16 to 4.37 for the Weibull form). These models are both of a form suitable for practical use in modelling UV disinfection data. Results of this research highlight the impact of water quality, as influenced by the combined effect of UV dose, suspended solids concentration and UV absorbance, on small-scale UV disinfection for potable water production. Importantly, results show that the concentration of soluble UV absorbing agents and suspended solids are not in themselves sufficient criteria on which to base assessment of efficacy of UV disinfection / http://proxy.library.adelaide.edu.au/login?url= http://library.adelaide.edu.au/cgi-bin/Pwebrecon.cgi?BBID=1342403 / Thesis (M.Eng.Sc.) - University of Adelaide, School of Chemical Engineering, 2008
330

Ultraviolet disinfection kinetics for potable water production.

Amos, Steve A. January 2008 (has links)
Irradiation with ultraviolet (UV) light is used for the disinfection of bacterial contaminants in the production of potable water, and in the treatment of selected wastewaters. However, efficacy of UV disinfection is limited by the combined effect of suspended solids concentration and UV absorbance. Limited published UV disinfection data are available that account for the combined effects of UV dose, suspended solids concentration and UV absorbance. This present lack of a rigorous quantitative understanding of the kinetics of UV disinfection limits process optimisation and wider application of UV treatment. The development and validation of an adequate model to describe UV disinfection kinetics presented in this thesis can therefore be justified by an increased confidence of reliability of design for UV disinfection. Using the published data of Nguyen (1999), four established model forms were assessed to account for the combined effect of suspended solids and/or soluble UV absorbing compounds, and UV dose on the efficacy of disinfection. The four model forms were: a log-linear form, Davey Linear-Arrhenius (DL-A), Square-Root (or Ratkowsky- Belehradek) and a general nth order Polynomial (nOP) form that was limited to a third order. Criteria for assessment of an adequate predictive model were established including: accuracy of predicted against observed values, percent variance accounted for (%V), and; appraisal of residuals. The DL-A model was shown to best fit the data for UV disinfection of Escherichia coli (ATCC 25922); followed by the nOP, log-linear and Square-Root forms. However, the DL-A form must be used in conjunction with a first-order chemical reaction equation, and was shown to predict poorly at high experimental values of UV dose (> 40,000 μWs cm-2). The DL-A model was not amenable to extrapolation beyond the observed UV dose range. To overcome the shortcomings of the Davey Linear-Arrhenius model synthesis of two new, non-linear model forms was undertaken. The two models were a modified exponentially damped polynomial (EDPm) and a form based on the Weibull probability distribution. The EDPm model has three terms: a rate coefficient (k), a damping coefficient (λ), and; a breakpoint dose ([dose]B). The rate coefficient governs the initial rate of disinfection prior to the onset of tailing, whilst the breakpoint is the UV dose that indicates the onset of tailing. The damping coefficient controls curvature in the survivor curve. The Weibull model has just two terms: a dimensionless scale parameter (β0), and; a shape parameter (β1). The scale parameter represents the level of disinfection in the tail of the survivor curve (as log10 N/N0), whilst the shape parameter governs the degree of curvature of the survivor data. Each model was assessed against the independent and published UV disinfection data of Nelson (2000) for treatment of faecal coliforms in a range of waste stabilisation pond effluents. Both models were found to be well suited to account for tailing in these UV disinfection data. Overall, the EDPm model gave a better fit to the data than the Weibull model form. To rigorously validate the suitability of the new EDPm and Weibull models a series of experimental trials were designed and carried out in a small-scale pilot UV disinfection unit. These trials included data determined specifically at low values of UV dose (<10,000 μWs cm-2) to fill the gap in the experimental data of Nguyen (1999). The experimental trials were carried out using a commercially available, UV disinfection unit (LC5TM from Ultraviolet Technology of Australasia Pty Ltd). Purified water contaminated with Escherichia coli (ATCC 25922) with a range of feed water flow rates (1 to 4 L min-1) was used. E. coli was selected because it is found in sewage, or water contaminated with faecal material, and is used as an indicator for the presence of enteric pathogens. E. coli should not be present in potable water. The hydrodynamics of water flow within the disinfection unit were established using digital video photography of dye trace studies with Methylene Blue. Nominal UV dose (2,700 to 44,200 μWs cm-2) was controlled by manipulating the flow rate of feed water through the UV disinfection unit (i.e. residence time), or by varying the exposed length of the control volume of the disinfection unit. The transmittance of the feed water (at 254 nm) was adjusted by the addition of either a soluble UV absorbing agent (International RoastTM instant coffee powder; 0.001 to 0.07 g L-1), or by addition of suspended matter as diatomaceous earth (Celite 503TM; 0.1 to 0.7 g L-1, with a median particle size of 23 μm). The absorbing agent (instant coffee), when in a comparable concentration, was found to produce a greater reduction in water transmission than the suspended material (Celite 503TM). It therefore contributed to a greater reduction in the initial rate of disinfection. Neither agent was found to produce a systematic reduction in the observed efficacy of disinfection however. Experimental results highlight that in the absence of soluble absorbing agents, or suspended solids, the initial rate of disinfection is higher when fewer viable bacteria are initially present. Both the new EDPm and Weibull forms gave a good fit to the experimental data. The EDPm better fitted the data on the basis of residual sum-of-squares (0.03 to 2.13 for EDPm cf. 0.16 to 4.37 for the Weibull form). These models are both of a form suitable for practical use in modelling UV disinfection data. Results of this research highlight the impact of water quality, as influenced by the combined effect of UV dose, suspended solids concentration and UV absorbance, on small-scale UV disinfection for potable water production. Importantly, results show that the concentration of soluble UV absorbing agents and suspended solids are not in themselves sufficient criteria on which to base assessment of efficacy of UV disinfection / http://proxy.library.adelaide.edu.au/login?url= http://library.adelaide.edu.au/cgi-bin/Pwebrecon.cgi?BBID=1342403 / Thesis (M.Eng.Sc.) - University of Adelaide, School of Chemical Engineering, 2008

Page generated in 0.0929 seconds