• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 108
  • 14
  • Tagged with
  • 122
  • 42
  • 38
  • 23
  • 22
  • 18
  • 18
  • 17
  • 16
  • 15
  • 15
  • 14
  • 12
  • 12
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Uppvärmning av Björkö Friskola : Ett uppdrag för Stiftelsen Waldorfpedagogik i Vreta Kloster

Holmberg, Albin, Kindahl, Mikael January 2015 (has links)
Detta arbete gick i huvuddrag ut på att undersöka uppvärmningsproblematiken på Björkö Friskola i Linköping. Uppdraget hade som huvudsyfte att finna en lösning på det kalla inomhusklimatet i skolbyggnaderna. Det ingick även att finna lösningar på problem som anläggningen dragits med sedan byggnation. Efter avgasmätning på fjärrvärmepannorna konstaterades det att en av dessa utvecklade mycket låg effekt och hade dålig förbränning. En optimering av förbränningen utfördes som resulterade i mindre pannunderhåll och mindre miljöpåverkan. Björkö Friskola stod inför ett beslut om att bygga en ny matsal, och ville ha underlag för om det var möjligt att ansluta denna byggnad till fjärrvärmen. Därför utfördes det beräkningar på om detta, rent teoretiskt skulle vara möjligt. Byggnaderna på området förbrukar vid årsmedeltemperatur cirka 27 kW och vid en utomhustemperatur på -200C, cirka 82 kW. Jämfördes detta med den installerade panneffekten som var 337 kW kunde det konstateras att anläggningen i sitt nuvarande utförande skulle klara av ytterligare en anslutning. / This diploma thesis was mainly focused to investigate the heating problems of Björkö Friskola. The assignment had as main objective to find a solution on the cool indoor climate in the school buildings. It was also included to find solutions on problems that have affected the plant since construction. Exhaust gas measurement was performed on the boilers and from those values it could be established that one boiler had extremely low effect and bad combustion. A combustion optimization was performed that resulted in less boiler maintenance and reduced environmental impact. Björkö Friskola faced a decision to build a new school canteen and has considered whether it was possible to connect this building to the district heating. Thereby calculations were made in order to decide whether this could be possible theoretically. The buildings on the area during average annual temperatures consume approximately 27 kW and during a temperature of -200C, approximately 82 kW. Compared this to the total installed boiler output that was 337 kW it could be noted that the facility in its current version could facilitate another connection.
2

Vindkraft för uppvärmning

Sjöberg, Per, Klasson, Robert January 2008 (has links)
<p>This final thesis contains three major parts, which all have been time demanding:</p><p>* Designing and construction of a small wind turbine.</p><p>* Designing and construction of an electrical system.</p><p>* Thesis with fundamental facts about wind, wind power and design.</p><p>The thesis contains basic theory in wind power and the energy systems it can be combined with. Different types of wind turbines, which components they consists of and important issues to consider when designing is also mentioned. In the end of this report the technique of our wind turbine will be presented. In the end you can also read about our experiences during the time of designing and construction.</p>
3

Översyn av uppvärmning

Revelj, Jonas, Svensson, Patrik January 2008 (has links)
<p>The heating of companies premises is today functional with electrical heating and heating of</p><p>fossil fuel. The energy cost for these kinds of heating in buildings has heavily increased during</p><p>the last years and the influence on the environment has become more visual. This leads to that</p><p>enterprises today become more anxious to render energy more effective and find alternative</p><p>solutions to their ancient heating systems. This is something that Skandinaviska kraftprodukter</p><p>AB in Halmstad has become aware of.</p><p>The purpose with this examination is to find the most cost-efficient and environmental measures</p><p>for the office and workshop premises of SKP AB. Where one of the bigger things is to find a</p><p>good alternative for their current oil furnace, which was heating the workshop. Another big thing</p><p>was to take forward suggestions for measures of rendering energy more effective for the</p><p>buildings. By taking contact with people in the business and by inspecting the premises and the</p><p>heating system, we got an idea about the measures that could be of current interest. We analysed</p><p>these measures to see if they could last financially and environmentally. At the financial analysis</p><p>we used LCC-method which means that you calculate the cost of the investment during its life.</p><p>With the heating system this means, among other things, running, maintenance and initial costs.</p><p>To examine the affect on the environment from the different heating alternatives we chose to</p><p>make a easier LCA, which we based on the local conditions.</p><p>In an existing building it is the simple measures of rendering energy that dominates financially,</p><p>the bigger investments don’t create financial expectations high enough with the energy prices of</p><p>today. In the workshop it was foremost a number of industrial gates that led to great heating</p><p>losses, which would best be taken care off by PVC-stripes curtain or automatic shutoff of the</p><p>heating system when the gates are open. Another alternative would be to invest in aircurtain. This</p><p>would reduce the heating losses a lot, but because of the large investment cost is this not an</p><p>option. The most cost-efficient measure is to increase the awareness of the employees, about how</p><p>their behaviour is affecting the use of energy and to make sure that heat and ventilation doesn’t</p><p>run unnecessarily.</p><p>While going through possible heating alternatives for the workshop, three alternatives seemed the</p><p>most interesting, air-to-air heat pump district heating and pellets. When it came to the financial</p><p>aspects where there no great difference between the three alternatives, when you looked at a</p><p>calculation period over 30 years. Environmentally heat pump was the best choice because the</p><p>electricity of HEM is water produced. The district heating had the highest affect on the</p><p>environment because it partially comes from waste burning, which leads to large emissions. From</p><p>comfort and maintenance point of view we think that the district heating is the best alternative for</p><p>the enterprise, foremost because you don’t have to maintain the system and it can heat the</p><p>premises even during the coldest days. The downside with pellets is that it brings a curtain</p><p>amount of maintenance and that pellets storage takes a lot of place. The downside of heat pump is</p><p>that it doesn’t have enough effect to cope with the coldest days.</p><p>Our recommendation of heating system is district heating. It is true it has the biggest influence on</p><p>the environment but because it can handle the need for heat during all parts of the year and that it</p><p>is free of maintenance ways up for its influence on the environment.</p>
4

Vindkraft för uppvärmning

Sjöberg, Per, Klasson, Robert January 2008 (has links)
This final thesis contains three major parts, which all have been time demanding: *Designing and construction of a small wind turbine. *Designing and construction of an electrical system. *Thesis with fundamental facts about wind, wind power and design. The thesis contains basic theory in wind power and the energy systems it can be combined with. Different types of wind turbines, which components they consists of and important issues to consider when designing is also mentioned. In the end of this report the technique of our wind turbine will be presented. In the end you can also read about our experiences during the time of designing and construction.
5

Översyn av uppvärmning

Revelj, Jonas, Svensson, Patrik January 2008 (has links)
The heating of companies premises is today functional with electrical heating and heating of fossil fuel. The energy cost for these kinds of heating in buildings has heavily increased during the last years and the influence on the environment has become more visual. This leads to that enterprises today become more anxious to render energy more effective and find alternative solutions to their ancient heating systems. This is something that Skandinaviska kraftprodukter AB in Halmstad has become aware of. The purpose with this examination is to find the most cost-efficient and environmental measures for the office and workshop premises of SKP AB. Where one of the bigger things is to find a good alternative for their current oil furnace, which was heating the workshop. Another big thing was to take forward suggestions for measures of rendering energy more effective for the buildings. By taking contact with people in the business and by inspecting the premises and the heating system, we got an idea about the measures that could be of current interest. We analysed these measures to see if they could last financially and environmentally. At the financial analysis we used LCC-method which means that you calculate the cost of the investment during its life. With the heating system this means, among other things, running, maintenance and initial costs. To examine the affect on the environment from the different heating alternatives we chose to make a easier LCA, which we based on the local conditions. In an existing building it is the simple measures of rendering energy that dominates financially, the bigger investments don’t create financial expectations high enough with the energy prices of today. In the workshop it was foremost a number of industrial gates that led to great heating losses, which would best be taken care off by PVC-stripes curtain or automatic shutoff of the heating system when the gates are open. Another alternative would be to invest in aircurtain. This would reduce the heating losses a lot, but because of the large investment cost is this not an option. The most cost-efficient measure is to increase the awareness of the employees, about how their behaviour is affecting the use of energy and to make sure that heat and ventilation doesn’t run unnecessarily. While going through possible heating alternatives for the workshop, three alternatives seemed the most interesting, air-to-air heat pump district heating and pellets. When it came to the financial aspects where there no great difference between the three alternatives, when you looked at a calculation period over 30 years. Environmentally heat pump was the best choice because the electricity of HEM is water produced. The district heating had the highest affect on the environment because it partially comes from waste burning, which leads to large emissions. From comfort and maintenance point of view we think that the district heating is the best alternative for the enterprise, foremost because you don’t have to maintain the system and it can heat the premises even during the coldest days. The downside with pellets is that it brings a curtain amount of maintenance and that pellets storage takes a lot of place. The downside of heat pump is that it doesn’t have enough effect to cope with the coldest days. Our recommendation of heating system is district heating. It is true it has the biggest influence on the environment but because it can handle the need for heat during all parts of the year and that it is free of maintenance ways up for its influence on the environment.
6

Uppvärmd konstgräsplan : Beräkning av utnyttjningstid för en uppvärmd konstgräplan med alternativa rörplaceringar / Artificial turf field with warming : A study of the utilization time for a turf field with warming with different tube placements

Umas, Sertac January 2014 (has links)
For Skattkärr IF a turf field with warming has been projected to increase field’s utilization hours and to have a longer period for athletes to perform their activities outdoors. The technique chosen to heat the plan is a type of a geothermal heating system without a heat pump. The brine, which is water with 30% ethanol, collects heat from the borehole and discharges it to a coil in the field. There is at position 11 boreholes but it is planned to increase the number to 31, which is the design for the facility. The operating cost of the system consists of a pump. The heating cables, which are connected in parallel, consist of PVC tube and the total length is about 40 kilometers. The heating cables are 154 mm in plan, with a c/c distance of 200 mm. Forward and return line temperatures are 5.5°C and 2.5°C and the flow is 73m3/h. The purpose of this work is to explore how the placement of coils (laying depth and c/c distance) affect heat transport capability of the plan area, describe the utilization time that can be expected for the football field in Skattkärr and calculate the impact of the heating system on the football field utilization time . The goal of this work is to create a mathematical model using computer programs that describe the surface temperature over a year. For artificial turf pitch to be playable the surface temperature should be at least 0°C. The model whose task was to describe the surface temperature was built in the program Simulink, (a part of Matlab) and consisted of several descriptions of energy flows, amongst others: convection, radiation and evaporation. To describe the heat flow from the pipe to the surface, the program Comsol was used. Various heat transfer coefficients were calculated with different tube placements later used in Simulink. The results show that with the heating system, utilization hours increased from 4200 hours to 4800 hours per year. With a c/c distance of 150 mm and an installation depth of 100 mm, useful hours can be increased by another 400 hours. According to the model, a brine temperature of 40ºC is required to increase the utilization time up to 7000 hours per year, with a calculated electricity consumption of about 262 MWh/year. The sensitivity analysis performed on the material's thermal conductivity shows that the choice of material for similar heating systems is important and affects the heat flow from the pipe to the surface.
7

Hur muskelaktiveringen påverkas vid en inåtrotation i axelleden med och utan Activation Grip. / How the muscle activation is affected during an internal rotation of the shoulder joint with and without Activation Grip.

Abrahamsson, Filip, Björklin, Jimmy January 2012 (has links)
Bakgrund: Även om kaströrelsen i detalj skiljer sig mellan olika idrotter så är den biomekaniska funktionen i grunden densamma. Inom alla kastrelaterade idrotter återkommer den så kallade accelerationsfasen, här har det visat sig att inåtrotationen i axelleden har en hög korrelation med bollhastighet i kaströrelsen. Axelledens inåtrotatorer har alltså en viktig funktion för ett effektivt kast. En funktionell uppvärmning av dessa strukturer optimerar prestationsförmågan och minskar skaderisken. Kan träningsredskapet Activation Grip (AG) effektivisera uppvärmningen av den övre extremiteten hos kastidrottare? Syfte: Att undersöka och jämföra hur muskelaktiviteten i m. pectoralis major (PM), m. deltoideus anterior (DA), m. flexor carpi raidalis (FCR) och m. extensor digitoris communis (EDC) påverkas vid inåtrotation i axelleden med och utan träningsredskapet AG. Studien syftar även till att utvärdera AG som produkt. Metod: Muskelaktiviteten i PM, DA, FCR och EDC registrerades med hjälp av elektromyografi (sEMG) hos 18 aktiva idrottare inom överarmskastrelaterade idrotter (ålder 23,7 ± 5,7) vid inåtrotation i axelleden med maximal hastighet, jämfört med samma rörelse med AG och 30% belastning. Resultat: Resultatet visade på en signifikant högre muskelaktivering (p &lt; 0.05) i DA, FCR, EDC under inåtrotationen med maximal hastighet. Hos PM sågs ingen signifikant skillnad i muskelaktivitet. AG fick över lag positiv respons från testdeltagarna.  Konklusion: Med resultatet i beaktande så skulle AG kunna kombineras tillsammans med andra uppvärmningsövningar för att få specifik aktivering i önskad muskulatur. Vidare studier gällande rörelse, motstånd och hastighet för att effektivisera användningen av AG bör göras. Även om AG fick positiv respons så bör produkten utvecklas ytterligare.
8

Uppvärmningssystem för att påskynda härdning av betong : Ett arbete om vilka anordningar som finns för att värma byggarbetsplatser och deras energiåtgång

Lorentzon, Johan, Larsson, Oscar January 2010 (has links)
År 2004 förbrukades 5 037 800 MWh energi i byggsektorn. Idag pratas det mycket om energieffektivisering i förvaltningsskedet. Denna rapport inriktar sig mer på hur energiförbrukningen kan minskas under bygget, närmare bestämt hur valet av uppvärmningssystem för att påskynda härdningen av betong på byggarbetsplatsen kan minska energianvändningen. Energianvändningen är något som påverkar både ekonomin och miljön, det är därför aktuellt att spara på energin där det är möjligt.  Det finns en rad olika uppvärmningsanordningar för att torka betong, att välja den mest lämpade för bygget är av stor vikt. Både ur ett tidsperspektiv och även ur energibesparingsperspektiv. Rapporten berör de idag mest använda anordningarna men fokuserar på de anordningar som torkar och härdar betongen genom att värma luften; eldrivna varmluftsfläktar, hetvattendrivna luftvärmare, dieseleldade byggtorkar samt gasoleldade byggtorkar. Anordningarna jämförs utifrån koldioxidutsläpp, kostnader samt sina för- och nackdelar för användning på arbetsplatsen. För att underlätta valet av uppvärmningsanordning har ett program tagits fram där kostnader och koldioxidutsläpp beräknas. Programmet fungerar som så att effektbehovet beräknas och utifrån detta väljer användaren de mest lämpade anordningarna för bygget i fråga. I rapporten jämförs de fyra uppvärmningsanordningarna i två olika månader, november och februari, samt med dålig isolering och obefintlig isolering i uppvärmningsskedet. Beräkningarna i rapporten är utförda på ett standard flerbostadshus för Peab. Resultatet av de utförda beräkningarna visas i diagrammen ovan. Slutsatsen av rapporten blir att vid högre effektbehov, och om möjligheten finns, är det alltid bäst att använda sig av fjärrvärme sett till de totala kostnaderna och koldioxidutsläppen. Där effektbehovet och ett fjärrvärmesystem inte motiveras ekonomiskt bör ett gasolbaserat system användas. Ett diesel- och elbaserat system är i ett tidigt skede aldrig en bra lösning på grund av höga kostnader för energin och stora utsläpp.
9

Global uppvärmning : A survey of students’ knowledge about the phenomenon

Gustafsson, Robert January 2008 (has links)
<p>Global warming is one of the most debated environmental issues right now, and it could be argued that it is important to study how the phenomenon is treated in schools. The main purpose of this study is to put students’ knowledge about global warming in relation with the control documents for chemistry, biology and physics studies. Interviews have been conducted with six students in the 9th grade. The conclusion of the survey indicates that the students generally have a satisfying knowledge about the phenomenon and that they know how they should behave from an environmental perspective.</p>
10

Uppvärmningssystem för att påskynda härdning av betong : Ett arbete om vilka anordningar som finns för att värma byggarbetsplatser och deras energiåtgång

Lorentzon, Johan, Larsson, Oscar January 2010 (has links)
<p>År 2004 förbrukades 5 037 800 MWh energi i byggsektorn. Idag pratas det mycket om energieffektivisering i förvaltningsskedet. Denna rapport inriktar sig mer på hur energiförbrukningen kan minskas under bygget, närmare bestämt hur valet av uppvärmningssystem för att påskynda härdningen av betong på byggarbetsplatsen kan minska energianvändningen. Energianvändningen är något som påverkar både ekonomin och miljön, det är därför aktuellt att spara på energin där det är möjligt.</p><p> Det finns en rad olika uppvärmningsanordningar för att torka betong, att välja den mest lämpade för bygget är av stor vikt. Både ur ett tidsperspektiv och även ur energibesparingsperspektiv. Rapporten berör de idag mest använda anordningarna men fokuserar på de anordningar som torkar och härdar betongen genom att värma luften; eldrivna varmluftsfläktar, hetvattendrivna luftvärmare, dieseleldade byggtorkar samt gasoleldade byggtorkar. Anordningarna jämförs utifrån koldioxidutsläpp, kostnader samt sina för- och nackdelar för användning på arbetsplatsen. För att underlätta valet av uppvärmningsanordning har ett program tagits fram där kostnader och koldioxidutsläpp beräknas. Programmet fungerar som så att effektbehovet beräknas och utifrån detta väljer användaren de mest lämpade anordningarna för bygget i fråga. I rapporten jämförs de fyra uppvärmningsanordningarna i två olika månader, november och februari, samt med dålig isolering och obefintlig isolering i uppvärmningsskedet. Beräkningarna i rapporten är utförda på ett standard flerbostadshus för Peab.</p><p>Resultatet av de utförda beräkningarna visas i diagrammen ovan. Slutsatsen av rapporten blir att vid högre effektbehov, och om möjligheten finns, är det alltid bäst att använda sig av fjärrvärme sett till de totala kostnaderna och koldioxidutsläppen. Där effektbehovet och ett fjärrvärmesystem inte motiveras ekonomiskt bör ett gasolbaserat system användas. Ett diesel- och elbaserat system är i ett tidigt skede aldrig en bra lösning på grund av höga kostnader för energin och stora utsläpp.</p>

Page generated in 0.0721 seconds