• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 44
  • 2
  • 1
  • Tagged with
  • 47
  • 47
  • 47
  • 37
  • 37
  • 29
  • 27
  • 23
  • 19
  • 18
  • 18
  • 16
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

[en] STATISTICAL METHODOLOGY FOR ANALYTICAL METHODS VALIDATION APPLICABLE CHEMISTRY METROLOGY / [pt] METODOLOGIA ESTATÍSTICA PARA VALIDAÇÃO DE MÉTODOS ANALÍTICOS APLICÁVEL À METROLOGIA EM QUÍMICA

SONIA MARIA DE FREITAS 31 October 2003 (has links)
[pt] A metodologia estatística escolhida para validação de métodos analíticos aplicável à metrologia em química é fundamental para assegurar a qualidade, comprovar a eficiência e demonstrar a exatidão dos resultados das medições nas análises químicas. Essa metodologia, desenvolvida em conformidade com o rigor metrológico, resulta num sistema de medições validado, confiável e com incertezas quantificadas. Este trabalho propõe uma metodologia geral para validação de métodos analíticos. A metodologia desenvolvida resultou de uma síntese de métodos parciais descritos na literatura, e inclui uma escolha crítica de técnicas mais adequadas dentro das alternativas existentes. A abordagem proposta combina quatro diferentes aspectos da validação: a modelagem da curva de calibração; o controle da especificidade do método; a comparação da tendência e precisão (repetitividade e precisão intermediária) do método com um método de referência; e a estimação das componentes de incerteza inerentes a todos esses aspectos. Como resultado, além de uma proposta para validação de métodos para uso em análises químicas, obtêm- se a função de calibração inversa e as incertezas expandidas, que permitem obter os resultados analíticos associados aos valores da resposta, com suas respectivas incertezas associadas. Na modelagem geral para obtenção da curva de calibração, empregam-se técnicas estatísticas para avaliação da linearidade e para o cálculo do mínimo valor detectável e do mínimo valor quantificável. A especificidade do método analítico é avaliada pela adição de padrões a um conjunto de amostras representativas e posterior recuperação dos mesmos, com ajuste por mínimos quadrados e testes de hipóteses. Para estudar a tendência e a precisão do método quando comparado a um método de referência, utiliza-se um modelo hierárquico de quatro níveis e a aproximação de Satterthwaite para determinação do número de graus de liberdade associados aos componentes de variância. As técnicas estatísticas utilizadas são ilustradas passo a passo por exemplos numéricos. / [en] The use of statistical methodology for analytical methods validation is vital to assure that measurements have the quality level required by the goal to be attained. This thesis describes a statistical modelling approach for combining four different aspects of validation: checking the linearity of the calibration curve and compute the detection and the quantification limits; controlling the specificity of the analytical method; estimating the accuracy (trueness and precision) of the alternative method, for comparison with a reference method. The general approach is a synthesis of several partial techniques found in the literature, according to a choice of the most appropriate techniques in each case. For determination of the response function, statistical techniques are used for assessing the fitness of the regression model and for determination of the detection limit and the quantification limit. Method specificity is evaluated by adjusting a straight line between added and recovered concentrations via least squares regression and hypotheses tests on the slope and intercept. To compare a method B with a reference method A, the precision and accuracy of method B are estimated. A 4-factor nested design is employed for this purpose. The calculation of different variance estimates from the experimental data is carried out by ANOVA. The Satterthwaite approximation is used to determine the number of degrees of freedom associated with the variance components. The application of the methodology is thoroughly illustrated with step-by-step examples.
42

Caracterização e análises do ascorbato de monometilsilanotriol em formulações cosméticas / Characterization and analysis of monomethylsilanetriol ascorbate in cosmetic formulations

Joyce Santos Quenca Guillen 07 December 2007 (has links)
O ascorbato de monometilsilanotriol (AMS) apresenta as propriedades cosméticas do ácido ascórbico. Além de ser um antioxidante e despigmentante, o AMS apresenta silício em sua estrutura, assim sua presença em formulações tópicas tem como objetivo repor o silício endógeno, proporcionando a regeneração do tecido. O presente trabalho tem por objetivo, caracterizar e analisar o AMS formulações cosméticas. Para caracterização do princípio ativo, foram empregadas as seguintes técnicas: espectrofotometria no ultravioleta, espectrofotometria na região do infravermelho com transformada de Fourier (FTIR), cromatografia em camada delgada, perda por dessecação, calorimetria exploratória diferencial (DSC), termogravimetria (TG), termogravimetria derivada (DTG) e análise do tamanho de partícula. Avaliou-se o potencial antioxidante in vitro do AMS pelos métodos de DPPH (2,2´-difenil-1- picrilhidrazil) e ORAC(Oxigen Radical Absorbance Capacity Assay) . Para avaliar o comportamento do princípio ativo em formulações cosméticas foi realizado um estudo de estabilidade acelerada, no qual as mesmas foram armazenadas nas seguintes condições: 40º C ± 2, câmera de fotoestabilidade 25º C, armário fechado à temperatura de 25º C± 2 e geladeira a 5º C ± 2. Foram avaliados os caracteres organolépticos, o pH e viscosidade aparente, também foram efetuadas análises por DSC, tamanho de partícula e microscopia de luz polarizada. Para determinação do AMS foi desenvolvido e validado um método por cromatografia líquida da alta eficiência (CLAE) em fase reversa por pareamento iônico. De acordo com os resultados obtidos por TG/DTG/DSC pode-se associar o comportamento térmico do ativo isolado com aquele da espécie incorporada em formulações. Segundo o método de tamanho de partícula, pode-se avaliar que o AMS, apresentou tamanho de aproximadamente 1 µm (919 nm) e índice de polidispersidade de 0,111. Durante os experimentos para determinação da atividade antioxidante por DPPH, o AMS demonstrou ter propriedade antioxidante tão efetiva quanto o ácido ascórbico. O valor de ORAC obtido para o AMS (0,74) é próximo ao valor de ORAC para o ácido ascórbico (0,95). As formulações estudadas mantiveram suas características organolépticas, estabilidade física e viscosidade aparente, assim como, não sofreram alterações relevantes em termos de pH durante o período de 90 dias. A metodologia desenvolvida para determinação do AMS apresentou boa linearidade, precisão, limites de detecção e quantificação, podendo ser usada na análise de formulações cosméticas. Esse princípio ativo, mostrou ser uma excelente alternativa, como derivado do ácido ascórbico, por apresentar atividade antioxidante in vitro tão eficiente quanto à desse, assim como, uma estabilidade superior em formulações cosméticas. / The monomethylsilanetriol ascorbate( MSA) presents the same functional properties of vitamin C. Besides presents antioxidant and depigmentant activity, the monomethylsilanetriol ascorbate presents silanol in it chemical structure. The silanol is a privileged active ingredient for cosmetics because it essential for growth, development and regeneration of cutaneous connective tissue. The aim of this work was characterize and analyze the MSA in cosmetic formulations. To characterize and identified MSA was employed: ultraviolet/visible (UV/VIS) spectrophotometry, fourier transform infrared spectrophotometry (FTIR), thin layer chromatography (TLC), thermogravimetry/derivative thermogravimetry (TG/DTG), differential scanning calorimetry (DSC) and particle size determination. For MSA in vitro antioxidant activity evaluation the DPPH (2,2-diphenyl-1-picrylhydrazyl) and ORAC (Oxigen Radical Absorbance Capacity Assay) method were used. To evaluate the behavior of MSA in cosmetic formulations the samples of emulsions were submitted to the accelerated stability study, for 90 days, were stored at 40 ± 2oC and light 25 ± 2oC. All samples were also stored at room temperature protected from light. Appearance, pH and apparent viscosity were evaluated. The DSC, particle size analyze and microscopy also were employed for analyze the cosmetic formulations. To determine MSA in formulations it was employed and validated a reversed phase HPLC method with ion pairing. According to the results obtained by TG/DTG/DSC the thermal behavior of isolated MSA can be associated with thermal behavior of MSA in formulations. Particle size distributions results showed that the average size was approximately 1 µm for MSA (919 nm) and polydispersity index of 0,111. During DPPH experiments, MSA presented antioxidant properties as good as vitamin C. The value of ORAC obtained for MSA was (0,74). The value of ORAC for ascorbic acid is 0,95. All samples remained stable throughout stability studies period. The developed methodology for determination of MSA presented good linearity, precision, limit of quantification and limit of detection and can be employed for analyze cosmetic formulations containing MSA. In conclusion, MSA might have interesting applications in cosmetic products and can be a good alternative for ascorbic acid derivative because it for demonstrated strong in vitro antioxidant properties as efficient as and more stable than vitamin C.
43

[en] ANALYSIS OF THE UNCERTAINTIES OF THE QUANTITATIVE PHASE ANALYSIS BY X-RAY POWDER DIFFRACTION BASED ON THE RIETVELD METHOD / [pt] ANÁLISE DAS INCERTEZAS DA QUANTIFICAÇÃO DE FASE PELO MÉTODO DE RIETVELD EM ANÁLISE DE PÓ POR DIFRAÇÃO DE RAIOS X

TEREZINHA FERREIRA DE OLIVEIRA 25 April 2005 (has links)
[pt] A análise de sistemas de medição consiste do exame da adequação do sistema quanto ao operador, ao instrumento e a outras fontes de variação, bem como da comparação da variância do erro de medição com a variância natural do processo. Nesse aspecto, esta pesquisa teve por objetivo a análise das incertezas da quantificação de fase pelo método de Rietveld em análise de pó. Os efeitos de vários fatores na quantificação de fase foram avaliados utilizando técnicas estatísticas de planejamento experimental e de análise multivariada, com a utilização de materiais de alto nível de rastreabilidade na realização dos experimentos, no Laboratório de difração de raios X do Departamento de Ciências de Materiais e Metalurgia da PUC-Rio. Através da determinação do construto de variação do processo, constatou-se que a quantificação das fases analisadas sofre influência das condições de medição de forma diferenciada de material para material, impossibilitando a obtenção de uma fórmula geral para cálculo dos erros de quantificação, embora os erros possam ser determinados por uma análise de repetitividade e reprodutibilidade apropriadamente conduzida. / [en] The analysis of measurement systems is done by the examination of the adequacy of the system according to the operator, the instrument and other sources of variability, as well as by the comparison of the measurement error variance with the natural process variance. This research consisted in the evaluation of the uncertainties of phase quantification in powder analysis by the Rietveld method. The evaluation of the effects of several factors on the phase quantification was performed using statistical techniques of design of experiments and of multivariate analysis, with the use of materials of high level of traceability for the conduction of the experiments, in the Laboratory of X-ray Diffraction of the Pontifícia Universidade Católica do Rio de Janeiro. Through the determination of the variational structure of the process it was verified that the analyzed phases suffer influence of the measurement conditions in a differentiated way, which prevents the obtention of a general formula for calculation of the quantification error, although the errors can be determined by a repeatability and reproducibility analysis properly conducted.
44

Электрохимическое определение серебра как основного антибактериального компонента в фармацевтической субстанции и готовой лекарственной форме : магистерская диссертация / Electrochemical determination of silver as the main component in antibacterial pharmaceutical substances and finished dosage form

Скосырева, Н. С., Skosyreva, N. S. January 2016 (has links)
Объектами исследования служили фармацевтическая субстанция «Аргамид» и готовая лекарственная форма 1% крем «Аргамид» на основе серебряной соли сульфадимидина (Приоритетная справка на выдачу патента № 2015153574 от 14.12.2015). Данная соль и лекарственные средства на ее основе были разработаны на базе кафедры фармации УГМУ с целью обеспечения российского фармацевтического рынка эффективными антибактериальными и ранозаживляющими лекарственными препаратами отечественного производства согласно стратегии развития фармацевтической промышленности «ФАРМА-2020». Цель работы: разработка и валидация методик количественного определения серебра в исследуемых лекарственных средствах. Анализ литературных данных показал, что оптимальным методом определения серебра является метод осадительного титрования с потенциометрической индикацией конечной точки титрования. При этом, учитывая содержание серебра в анализируемых лекарственных средствах, для его определения в субстанции был выбран метод роданометрического, а в готовой лекарственной форме – йодометрического титрования. Для анализируемых лекарственных средств были подобраны оптимальные условия пробоподготовки: масса навески, концентрация растворителя; время и температура обработки пробы. В качестве индикаторного вместо дорогостоящего импортного серебряного дискового электрода использовали отечественный толстопленочный серебросодержащий электрод. Положительные результаты валидационной оценки разработанных методик, проведенной согласно требованиям Государственной Фармакопеи РФ XIII изд., позволяют считать их приемлемыми и рекомендовать для включения в проекты фармакопейных статей на исследуемые лекарственные средства. Контроль содержания серебра по разработанным методикам не требует дорогостоящего оборудования, привлечения высококвалифицированного персонала, отличается относительно коротким временем анализа, а, следовательно, может применяться испытательными лабораториями предприятия в процессе производства и центрами контроля качества во время обращения на фармацевтическом рынке исследуемых лекарственных средств. / The objects of study were pharmaceutical substance "Argamid" and finished dosage form of 1% cream "Argamid" based on silver salt sulfadimidine (Priority reference patent number 2015153574 from 14.12.2015). This salt and drugs based on it have been developed at the Department of Pharmacy UGMU to ensure that the Russian pharmaceutical market effective antibacterial and wound healing medicines domestic production according to the strategy of development of the pharmaceutical industry "Pharma 2020". Objective: Development and validation of methods of quantitative determination of silver in the investigational medicinal product. Analysis of published data shows that the best method of determining silver is the method of precipitation titration with potentiometric indication end point. However, given the content of silver in the analyzed medicaments for identification substance rodanometricheskogo method was selected, and in the final dosage form - iodometric titration. optimal conditions for sample preparation were selected to be analyzed drugs: sample weight, the concentration of solvent; Sample processing time and temperature. As an indicator instead of expensive imported silver disk electrode used domestic thick-film silver-electrode. Positive results validation assessment developed techniques conducted in accordance with the requirements of the RF State Pharmacopoeia XIII ed., Allow us to consider them acceptable and recommended for inclusion in the draft articles on the pharmacopoeia investigational medicinal products. Control of the silver content by developed techniques does not require expensive equipment, highly skilled personnel, has a relatively short analysis time, and, therefore, can be applied testing laboratories of the enterprise in the production process and quality control center during handling in the pharmaceutical market of investigational medicinal products.
45

Вольтамперометрическое определение основного вещества противовирусного препарата Триазид® с использованием стеклоуглеродного электрода : магистерская диссертация / Voltammetric determination of the basic substance of the antiviral drug Triazid® using a glassy carbon electrode

Замана, А. А., Zamana, A. A. January 2018 (has links)
The object of the study was the pharmaceutical substance TRIAZID of the newest Russian antiviral drug azolo-azinovogo series containing nitro group. Objective: development and validation of the methodology for voltammetric determination of triazide in the pharmaceutical substance TRIAZID on a glassy carbon electrode. Analysis of literature data showed that in the case of biologically active nitro compounds, the most useful for quantitative determination is the electroreduction signal of the nitro group. The advantages of the signal include both the large amount of current generated per mole of the electroactive connection and the relatively low energy requirement for the reduction of the nitro group. This makes it possible to obtain a high current / concentration ratio at low recovery potentials. The conditions for obtaining an analytical signal of triazide on a glassy carbon electrode are optimized. A simple and expressive method for eliminating the interfering effect of dissolved oxygen with the help of sodium sulphite is proposed. / Объектом исследования служила фармацевтическая субстанция ТРИАЗИД новейшего российского противовирусного препарата азоло-азинового ряда, содержащего нитрогруппу. Цель работы: разработка и валидация методики вольтамперометрического определения триазида в фармацевтической субстанции ТРИАЗИД на стеклоуглеродном электроде. Анализ литературных данных показал, что в случае биологически активных нитросоединений наиболее полезным для количественного определения является сигнал электровосстановления нитрогруппы. К преимуществам сигнала можно отнести как большое количество тока, вырабатываемое на моль электроактивного соединения, так и относительно низкую потребность в энергии для восстановления нитрогруппы. Это позволяет получать высокое отношение ток / концентрация при низких потенциалах восстановления. Оптимизированы условия получения аналитического сигнала триазида на стеклоуглеродном электроде. Предложен простой и экспрессный способ устранения мешающего влияния растворенного кислорода с помощью сульфита натрия. Разработана и валидирована по актуальным требованиям Государственной Фармакопеи РФ XIII издания вольтамперометрическая методика определения триазида в фармацевтической субстанции ТРИАЗИД. Контроль содержания триазида по разработанной методике удовлетворяет заявленным критериям приемлемости, не требует дорогостоящего оборудования, привлечения высококвалифицированного персонала, отличается коротким временем анализа. При условии включения в фармстатью предприятия разработанный метод может применяться испытательными лабораториями предприятия в процессе производства препарата.
46

Determinação espectrofotométrica do cloridrato de ranitidina em medicamentos / Spectrophotometric determination of ranitidine hydrochloride in medicaments

Orsine, Eliane Maria de Almeida 07 May 1992 (has links)
O cloridrato de ranitidina, um antagonista dos receptores H2 da histamina, foi determinado em comprimidos e injetáveis por espectrofotometria no ultravioleta, a 313nm, e por espectrofotometria no visível, a 615nm, utilizando o cloridrato da hidrazona da 3-metil-2-benzotiazolinona (MBTH) a 0,35% em HCl 0,M e cloreto férrico a 0,40% em HCl 0,1M, como reagentes de cor. Na espectrofotometria no ultravioleta a lei de Beer foi obedecida no intervalo de concentração de 5,0 a 18,0 µg/mL. Quatro amostras comerciais foram analisadas. Os coeficientes de variação foram 0,36% e 0,71% para comprimidos, e 0,51% e 0,24% para injetáveis. A média de recuperação foi 99,88%. Na espectrofotometria no visível a lei de Beer foi obedecida no intervalo de concentração de 1,44 a 5,76 µg/mL. Os coeficientes de variação foram 0,72% e 0,59% para comprimidos, e 0,53% e 0,61% para injetáveis. A média de recuperação foi 99,39%. Os resultados foram comparados estatisticamente e foram compatíveis para as amostras que se encontravam em bom estado de conservação. / Ranitidine hydrochloride, a histamine H2-receptor antagonist, was determined in tablets and injections by ultraviolet spectrophotometry at 313nm , and visible spectrophotometry using as color reagent 0,35% 3-methyl-2-benzothiazolinone hydrochloride in HCl 0,1M and 0,40% ferric chloride in HCl 0,1M. In ultraviolet spectrophotometry, Beer\'s law was obeyed in the range of concentration from 5,0 to 18,0 µg/mL. Four commercially available were analyzed. The coefficients of variation were 0,36% and 0,71% for tablets, and 0,51% and 0,24% for injections. The recovery average was 99,88%. In visible spectrophotometry, Beer\'s law was obeyed in the range of concentration from 1,44 to 5,76 µg/mL. The coefficients of variation were 0,72% and 0,59% for tablets, and 0,53% and 0,61% for injections. The recovery average was 99,39%. The results obtained by using the two methods were statistically compared and were compatible when samples were kept in good conditions of storage.
47

Determinação espectrofotométrica do cloridrato de ranitidina em medicamentos / Spectrophotometric determination of ranitidine hydrochloride in medicaments

Eliane Maria de Almeida Orsine 07 May 1992 (has links)
O cloridrato de ranitidina, um antagonista dos receptores H2 da histamina, foi determinado em comprimidos e injetáveis por espectrofotometria no ultravioleta, a 313nm, e por espectrofotometria no visível, a 615nm, utilizando o cloridrato da hidrazona da 3-metil-2-benzotiazolinona (MBTH) a 0,35% em HCl 0,M e cloreto férrico a 0,40% em HCl 0,1M, como reagentes de cor. Na espectrofotometria no ultravioleta a lei de Beer foi obedecida no intervalo de concentração de 5,0 a 18,0 µg/mL. Quatro amostras comerciais foram analisadas. Os coeficientes de variação foram 0,36% e 0,71% para comprimidos, e 0,51% e 0,24% para injetáveis. A média de recuperação foi 99,88%. Na espectrofotometria no visível a lei de Beer foi obedecida no intervalo de concentração de 1,44 a 5,76 µg/mL. Os coeficientes de variação foram 0,72% e 0,59% para comprimidos, e 0,53% e 0,61% para injetáveis. A média de recuperação foi 99,39%. Os resultados foram comparados estatisticamente e foram compatíveis para as amostras que se encontravam em bom estado de conservação. / Ranitidine hydrochloride, a histamine H2-receptor antagonist, was determined in tablets and injections by ultraviolet spectrophotometry at 313nm , and visible spectrophotometry using as color reagent 0,35% 3-methyl-2-benzothiazolinone hydrochloride in HCl 0,1M and 0,40% ferric chloride in HCl 0,1M. In ultraviolet spectrophotometry, Beer\'s law was obeyed in the range of concentration from 5,0 to 18,0 µg/mL. Four commercially available were analyzed. The coefficients of variation were 0,36% and 0,71% for tablets, and 0,51% and 0,24% for injections. The recovery average was 99,88%. In visible spectrophotometry, Beer\'s law was obeyed in the range of concentration from 1,44 to 5,76 µg/mL. The coefficients of variation were 0,72% and 0,59% for tablets, and 0,53% and 0,61% for injections. The recovery average was 99,39%. The results obtained by using the two methods were statistically compared and were compatible when samples were kept in good conditions of storage.

Page generated in 0.0353 seconds