Spelling suggestions: "subject:"validity off tests"" "subject:"validity off pests""
1 |
Aplicabilidade, validação e reprodutibilidade do Spinal Cord Independence Measure version III (SCIM III) nos pacientes com paraparesia espástica / Applicability, validation and reproducibility of the Spinal Cord Independence Measure version III (SCIM III) in patients with spastic paraplegiaAlmeida, Camila de 18 December 2014 (has links)
Objetivo: verificar a aplicabilidade, reprodutibilidade e validade do SCIM III nos pacientes com paraparesia espástica. Método: estudo transversal incluindo 30 sujeitos (66% mulheres; 41,5±14,7 anos) com paraparesia espástica de etiologia genética, infecciosa ou a esclarecer que foram avaliados pela análise computadorizada da marcha, versão brasileira da SCIM III (0-100 pontos), MIF (18-126 pontos), por 2 examinadores (A e B) no mesmo dia e 1 semana depois (A). Resultados: o coeficiente de correlação intraclasse (CCI) para o uso da SCIM III indicou boa reprodutibilidade intra e inter-examinadores (CCI=0,9). A correlação de Spearman entre a SCIM III e a parte motora da MIF foi considerada adequada e estatisticamente significante (Spearman=0,6; p=0,001). A correlação entre as subescalas da SCIM III e os domínios da MIF foi considerada forte e significante para auto-cuidado (Spearman=0,8; p0,001) e moderada para transferências (Spearman=0,6; p=0,0005) e locomoção (Spearman=0,6; p=0,0006). A subescala mobilidade da SCIM III mostrou correlação positiva e significante para cadência (Spearman=0,8; p0,001), velocidade da marcha (Spearman=0,7; p0,001) e comprimento do passo (Spearman=0,6; p0,001). Conclusões: A SCIM III é um instrumento de avaliação funcional reprodutível intra e inter examinadores e capaz de avaliar o nível de independência dos indivíduos com paraparesia espástica. O SCIM III é mais sensível que a MIF, especialmente para pacientes com maior independência. Cadência, velocidade de marcha e comprimento do passo se correlacionaram com a subescala mobilidade / Purpose: to verify the applicability, reproducibility, and validity of the SCIM III patients with non-traumatic spastic paraplegia. Method: The cross-sectional study included 30 subjects (66% females; 41.5 ± 14.7 y) older with spastic paraparesis of any etiology were assessment by computerized gait analysis and with the Brazilian versions of SCIM III (0-100 points), FIM (18-126 points) by 2raters (A and B) at the same day and 1 week later (A). Results: The intraclass correlation coefficient (ICC) for the use of SCIM III indicated good intra and inter-evaluator reproducibility (ICC = 0.9). Correlation between the SCIM III and the motor FIM was appropriate (Spearman=0.6; p0.001). SCIM III subscales and the FIM domains correlated strongly for self-care (Spearman=0.8; p0.001), moderately for transfers (Spearman=0.6; p=0.0005) and locomotion (Spearman=0.6; p=0.0006). SCIM III mobility subscale positively correlated with the cadence (Spearman=0.8; p0.01), gait speed (Spearman=0.7; p0.01), and step length (Spearman=0.6;p0.01). Conclusions: SCIM III is a reproducible functional assessment instrument and capable of evaluating the level of independence of the individual with spastic paraplegia. The SCIM III is more sensitive than the FIM for non-traumatic spastic paraplegic patients with higher levels of independence. Linear gait parameters correlated with its mobility subscale.
|
2 |
Análise de um sistema de escaneamento 3D para avaliação das curvaturas sagitais e frontais da coluna vertebral de indivíduos de diferentes faixas etáriasMarques, Mariana Tonietto January 2013 (has links)
O padrão ouro para a avaliação e o acompanhamento de desvios posturais é o exame radiológico. No entanto, a exposição à radiação ionizante aumenta o risco do desenvolvimento de câncer. Nessa perspectiva, se faz necessário o uso de métodos não invasivos com validade, repetibilidade e reprodutibilidade para mensurar os desvios posturais e acompanhar a sua progressão. Dessa maneira, o intuito do presente estudo foi verificar se o sistema Vert 3D fornece informações válidas referentes aos desvios posturais nos planos frontal e sagital de indivíduos de diferentes faixas etárias. Além disso, verificar a repetibilidade e a reprodutibilidade interavaliador do sistema Vert 3D nos planos sagital e frontal. Foi avaliada a postura sagital e frontal de 89 crianças de ambos os sexos e diferentes faixas etárias. A avaliação consistiu de duas etapas: exame radiológico e sistema Vert 3D. A primeira etapa foi realizada por um operador de raios X experiente e, a partir das imagens geradas, foram calculados os ângulos de Cobb nos planos sagital e frontal. A segunda etapa foi executada no mesmo dia por três avaliadores treinados no método e foram calculados os ângulos de deformidade do Vert 3D nos planos sagital e frontal e as flechas de escoliose do Vert 3D. O primeiro avaliador efetuou duas análises sucessivas, o segundo avaliador efetuou em seguida outras duas análises sucessivas e o terceiro avaliador efetuou a seguir uma única análise. Foram comparados e correlacionados os dados sucessivos de um mesmo avaliador para verificar a repetibilidade, os dados de diferentes avaliadores para verificar a reprodutibilidade interavaliador e entre os dados dos dois sistemas para verificar a validade do sistema Vert 3D. Para a repetibilidade no plano sagital, não houve diferença (p>0,05) e as correlações foram excelentes (ICC≥0,750, p<0,05). Para a reprodutibilidade interavaliador no plano sagital, não houve diferença (p>0,05) e as correlações foram satisfatórias (0,400<ICC<0,750, p<0,05) para a cifose de indivíduos de 6 a 10 anos e 16 a 18 anos e para a lordose de indivíduos de 11 a 15 anos e excelentes (ICC≥0,750, p<0,05) para a cifose de indivíduos de 11 a 15 anos e para a lordose de indivíduos de 6 a 10 e de 16 a 18 anos. E para a validade no plano sagital, houve diferença (p<0,05) e as correlações entre os ângulos de deformidade do Vert 3D (cifose e lordose) e os ângulos de Cobb (cifose e lordose) foram moderadas (0,400<r<0,699, p<0,05) para a cifose de indivíduos de 11 a 18 anos e para a lordose de indivíduos de 6 a 18 anos. Para a repetibilidade no plano frontal, não houve diferença (p>0,05) e as correlações foram satisfatórias (0,400<ICC<0,750, p<0,05) a excelentes (ICC≥0,750, p<0,05) para as flechas de escoliose do Vert 3D de indivíduos de 6 a 18 anos e para os ângulos de deformidade do Vert 3D (escoliose) de indivíduos de 11 a 18 anos. Para a reprodutibilidade interavaliador, não houve diferença (p>0,05) e as correlações foram satisfatórias (0,400<ICC<0,750, p<0,05) para as flechas de escoliose do Vert 3D de indivíduos de 6 a 18 anos e para os ângulos de indivíduos de 11 a 18 anos. E para a validade no plano frontal, houve diferença (p<0,05) entre os ângulos dos dois sistemas e as correlações foram moderadas (0,400<rho< 0,699, p<0,05) em relação à média das flechas de escoliose do Vert 3D à esquerda e à média dos ângulos de deformidade do Vert 3D à esquerda. Tendo em vista os resultados para repetibilidade e reprodutibilidade do Vert 3D nos planos sagital e frontal, o sistema pode ser utilizado para o acompanhamento das posturas sagital e frontal de indivíduos de 6 a 18 anos, a partir dos ângulos de deformidade do Vert 3D (cifose e lordose) e das flechas de escoliose do Vert 3D. Além disso, pode ser utilizado para o acompanhamento da postura frontal de indivíduos de 11 a 18 anos, a partir dos ângulos de deformidade do Vert 3D (escoliose). No entanto, na ausência de validade em relação ao padrão ouro, esse instrumento não pode ser utilizado para fins de avaliação dos ângulos de Cobb (cifose, lordose e escoliose). / The gold standard for the assessment and monitoring of postural deviations is the radiological examination. However, exposure to X-rays increases the risk to develop cancer. At this view, it is necessary the use of valid, repeatable and reproducible non-invasive methods to measure and monitor the progression of the postural deviations. Thus, the aim of this study was to verify if the Vert 3D system provides valid information regarding the postural deviations in frontal and sagittal planes of individuals of different age groups. Also, check the repeatability and inter-rater reliability of the Vert 3D system in sagittal and frontal planes. We evaluated the sagittal and frontal posture of 89 children of both sexes and different age groups. The evaluation consisted of two steps: radiological examination and Vert 3D system. The first step was performed by an experienced X-rays operator and from X-ray images were calculated Cobb angles in the sagittal and frontal planes. The second step was performed on the same day by three trained in the method evaluators. Was calculated the Vert 3D deformity angles in the sagittal and frontal planes and the Vert 3D scoliosis arrows. The first evaluator carried out two successive analyzes, the second evaluator then made two other successive analyzes and after the third evaluator made a single analysis. Were compared and correlated successive data of the each evaluator to verify repeatability, data from different evaluators to verify inter-rater reliability reproducibility and data from each system to verify the validity of Vert 3D system. For repeatability the in sagittal plane, was no difference (p>0.05) and the correlations were excellent (ICC≥0.750, p<0.05). For inter-rater reliability in the sagittal plane, was no difference (p>0.05) and the correlations were satisfactory (0.400 <ICC<0.750, p<0.05) for kyphosis in 6-10 years old and 16-18 years old individuals and for lordosis of 11-15 years old individuals and fine (ICC≥0.750, p<0.05) for kyphosis in 11-15 years old individuals 11 to 15 years and for lordosis in 6-10 years old and 16-18 years old individuals. And for validity in the sagittal plane, was significant differences (p<0.05) and the correlations between Vert 3D deformity angles (kyphosis and lordosis) and Cobb angles (kyphosis and lordosis) were moderate (0.400<r<0.699, p<0.05) for kyphosis in 11-18 years old individuals and for lordosis in 6-18 years old individuals. For the repeatability in the frontal plane, was no difference (p>0.05) and the correlations were satisfactory (0.400<ICC<0.750, p <0.05) to excellent (ICC≥0.750, p <0.05) for Vert 3D scoliosis arrows in 6-18 years old individuals and for Vert 3D deformity angles (scoliosis) in 11-18 years old individuals 11-18 years. For inter-rater reliability, was no difference (p>0.05) and the correlations were satisfactory (0.400<ICC<0.750, p<0.05) for Vert 3D scoliosis arrows in 6- 18 years old individuals and Vert 3D deformity angles (scoliosis) in 11-18 years old individuals. And for validity in the frontal plane, was significant differences (p<0.05) between the angles of the two systems and the correlations were moderate (0.400<rho<0.699, p<0.05) to the mean of Vert 3D scoliosis left arrows and the mean of Vert 3D deformity left angles (scoliosis). Considering the results for repeatability and inter-rater reliability of Vert 3D in both planes, the system can be used for monitoring the sagittal and frontal postures of 6-18 years old individuals 6-18 years from Vert 3D deformity angles (kyphosis and lordosis) and from Vert 3D scoliosis arrows. Moreover, it can be used for monitoring the frontal posture of 11-18 years old individuals from Vert 3D deformity angles (scoliosis). However, in the absence of validity related to the gold standard, the Vert 3D system cannot be used for diagnosis of Cobb angles (kyphosis, scoliosis, lordosis).
|
3 |
Análise de um sistema de escaneamento 3D para avaliação das curvaturas sagitais e frontais da coluna vertebral de indivíduos de diferentes faixas etáriasMarques, Mariana Tonietto January 2013 (has links)
O padrão ouro para a avaliação e o acompanhamento de desvios posturais é o exame radiológico. No entanto, a exposição à radiação ionizante aumenta o risco do desenvolvimento de câncer. Nessa perspectiva, se faz necessário o uso de métodos não invasivos com validade, repetibilidade e reprodutibilidade para mensurar os desvios posturais e acompanhar a sua progressão. Dessa maneira, o intuito do presente estudo foi verificar se o sistema Vert 3D fornece informações válidas referentes aos desvios posturais nos planos frontal e sagital de indivíduos de diferentes faixas etárias. Além disso, verificar a repetibilidade e a reprodutibilidade interavaliador do sistema Vert 3D nos planos sagital e frontal. Foi avaliada a postura sagital e frontal de 89 crianças de ambos os sexos e diferentes faixas etárias. A avaliação consistiu de duas etapas: exame radiológico e sistema Vert 3D. A primeira etapa foi realizada por um operador de raios X experiente e, a partir das imagens geradas, foram calculados os ângulos de Cobb nos planos sagital e frontal. A segunda etapa foi executada no mesmo dia por três avaliadores treinados no método e foram calculados os ângulos de deformidade do Vert 3D nos planos sagital e frontal e as flechas de escoliose do Vert 3D. O primeiro avaliador efetuou duas análises sucessivas, o segundo avaliador efetuou em seguida outras duas análises sucessivas e o terceiro avaliador efetuou a seguir uma única análise. Foram comparados e correlacionados os dados sucessivos de um mesmo avaliador para verificar a repetibilidade, os dados de diferentes avaliadores para verificar a reprodutibilidade interavaliador e entre os dados dos dois sistemas para verificar a validade do sistema Vert 3D. Para a repetibilidade no plano sagital, não houve diferença (p>0,05) e as correlações foram excelentes (ICC≥0,750, p<0,05). Para a reprodutibilidade interavaliador no plano sagital, não houve diferença (p>0,05) e as correlações foram satisfatórias (0,400<ICC<0,750, p<0,05) para a cifose de indivíduos de 6 a 10 anos e 16 a 18 anos e para a lordose de indivíduos de 11 a 15 anos e excelentes (ICC≥0,750, p<0,05) para a cifose de indivíduos de 11 a 15 anos e para a lordose de indivíduos de 6 a 10 e de 16 a 18 anos. E para a validade no plano sagital, houve diferença (p<0,05) e as correlações entre os ângulos de deformidade do Vert 3D (cifose e lordose) e os ângulos de Cobb (cifose e lordose) foram moderadas (0,400<r<0,699, p<0,05) para a cifose de indivíduos de 11 a 18 anos e para a lordose de indivíduos de 6 a 18 anos. Para a repetibilidade no plano frontal, não houve diferença (p>0,05) e as correlações foram satisfatórias (0,400<ICC<0,750, p<0,05) a excelentes (ICC≥0,750, p<0,05) para as flechas de escoliose do Vert 3D de indivíduos de 6 a 18 anos e para os ângulos de deformidade do Vert 3D (escoliose) de indivíduos de 11 a 18 anos. Para a reprodutibilidade interavaliador, não houve diferença (p>0,05) e as correlações foram satisfatórias (0,400<ICC<0,750, p<0,05) para as flechas de escoliose do Vert 3D de indivíduos de 6 a 18 anos e para os ângulos de indivíduos de 11 a 18 anos. E para a validade no plano frontal, houve diferença (p<0,05) entre os ângulos dos dois sistemas e as correlações foram moderadas (0,400<rho< 0,699, p<0,05) em relação à média das flechas de escoliose do Vert 3D à esquerda e à média dos ângulos de deformidade do Vert 3D à esquerda. Tendo em vista os resultados para repetibilidade e reprodutibilidade do Vert 3D nos planos sagital e frontal, o sistema pode ser utilizado para o acompanhamento das posturas sagital e frontal de indivíduos de 6 a 18 anos, a partir dos ângulos de deformidade do Vert 3D (cifose e lordose) e das flechas de escoliose do Vert 3D. Além disso, pode ser utilizado para o acompanhamento da postura frontal de indivíduos de 11 a 18 anos, a partir dos ângulos de deformidade do Vert 3D (escoliose). No entanto, na ausência de validade em relação ao padrão ouro, esse instrumento não pode ser utilizado para fins de avaliação dos ângulos de Cobb (cifose, lordose e escoliose). / The gold standard for the assessment and monitoring of postural deviations is the radiological examination. However, exposure to X-rays increases the risk to develop cancer. At this view, it is necessary the use of valid, repeatable and reproducible non-invasive methods to measure and monitor the progression of the postural deviations. Thus, the aim of this study was to verify if the Vert 3D system provides valid information regarding the postural deviations in frontal and sagittal planes of individuals of different age groups. Also, check the repeatability and inter-rater reliability of the Vert 3D system in sagittal and frontal planes. We evaluated the sagittal and frontal posture of 89 children of both sexes and different age groups. The evaluation consisted of two steps: radiological examination and Vert 3D system. The first step was performed by an experienced X-rays operator and from X-ray images were calculated Cobb angles in the sagittal and frontal planes. The second step was performed on the same day by three trained in the method evaluators. Was calculated the Vert 3D deformity angles in the sagittal and frontal planes and the Vert 3D scoliosis arrows. The first evaluator carried out two successive analyzes, the second evaluator then made two other successive analyzes and after the third evaluator made a single analysis. Were compared and correlated successive data of the each evaluator to verify repeatability, data from different evaluators to verify inter-rater reliability reproducibility and data from each system to verify the validity of Vert 3D system. For repeatability the in sagittal plane, was no difference (p>0.05) and the correlations were excellent (ICC≥0.750, p<0.05). For inter-rater reliability in the sagittal plane, was no difference (p>0.05) and the correlations were satisfactory (0.400 <ICC<0.750, p<0.05) for kyphosis in 6-10 years old and 16-18 years old individuals and for lordosis of 11-15 years old individuals and fine (ICC≥0.750, p<0.05) for kyphosis in 11-15 years old individuals 11 to 15 years and for lordosis in 6-10 years old and 16-18 years old individuals. And for validity in the sagittal plane, was significant differences (p<0.05) and the correlations between Vert 3D deformity angles (kyphosis and lordosis) and Cobb angles (kyphosis and lordosis) were moderate (0.400<r<0.699, p<0.05) for kyphosis in 11-18 years old individuals and for lordosis in 6-18 years old individuals. For the repeatability in the frontal plane, was no difference (p>0.05) and the correlations were satisfactory (0.400<ICC<0.750, p <0.05) to excellent (ICC≥0.750, p <0.05) for Vert 3D scoliosis arrows in 6-18 years old individuals and for Vert 3D deformity angles (scoliosis) in 11-18 years old individuals 11-18 years. For inter-rater reliability, was no difference (p>0.05) and the correlations were satisfactory (0.400<ICC<0.750, p<0.05) for Vert 3D scoliosis arrows in 6- 18 years old individuals and Vert 3D deformity angles (scoliosis) in 11-18 years old individuals. And for validity in the frontal plane, was significant differences (p<0.05) between the angles of the two systems and the correlations were moderate (0.400<rho<0.699, p<0.05) to the mean of Vert 3D scoliosis left arrows and the mean of Vert 3D deformity left angles (scoliosis). Considering the results for repeatability and inter-rater reliability of Vert 3D in both planes, the system can be used for monitoring the sagittal and frontal postures of 6-18 years old individuals 6-18 years from Vert 3D deformity angles (kyphosis and lordosis) and from Vert 3D scoliosis arrows. Moreover, it can be used for monitoring the frontal posture of 11-18 years old individuals from Vert 3D deformity angles (scoliosis). However, in the absence of validity related to the gold standard, the Vert 3D system cannot be used for diagnosis of Cobb angles (kyphosis, scoliosis, lordosis).
|
4 |
Validação de um sistema de escaneamento 3d para avaliação das curvaturas da coluna vertebral de crianças em diferentes perfis nutricionaisSedrez, Juliana Adami January 2013 (has links)
A presente dissertação de mestrado teve como objetivo verificar a validade concorrente, a repetibilidade, a reprodutibilidade interavaliador, a sensibilidade e a especificidade do sistema Vert 3D na avaliação das curvaturas frontais e sagitais de crianças com diferentes perfis nutricionais. Inicialmente foram realizadas duas revisões sistemáticas da literatura com o objetivo de investigar a existência de evidências científicas sobre os instrumentos de avaliação não invasiva da escoliose, cifose torácica e lordose lombar. A partir dessas revisões sistemáticas foi possível observar que, em geral, os instrumentos apresentaram condições satisfatórias para a avaliação não invasiva das curvaturas da coluna vertebral. Além disso, parece haver consenso na literatura sobre a aplicabilidade dos instrumentos não invasivos, os quais são indicados para o acompanhamento clínico, com o objetivo de reduzir a exposição frequente aos Raios-X sem, no entanto, possibilitar a substituição da radiografia. No entanto, ainda há carência na literatura de estudos com forte evidência científica no que tange a validação dos instrumentos não invasivos de avaliação da coluna vertebral, e por esse motivo, desenvolveu-se um estudo original com a finalidade de investigar os aspectos de validação do sistema Vert 3D. Foram avaliadas 115 crianças, as quais foram submetidas à radiografia panorâmica da coluna vertebral sagital e frontal, além de cinco avaliações com o sistema Vert 3D, por três avaliadores treinados. Os resultados demonstraram que o sistema Vert 3D: (1) apresentou excelentes níveis de repetibilidade e reprodutibilidade interavaliador para os ângulos de cifose torácica e lordose lombar; (2) apresentou fraca correlação com o ângulo de Cobb para cifose torácica e correlação moderada para lordose lombar; (3) para avaliação do plano frontal, o sistema Vert 3D apresentou nível moderado de repetibilidade para flechas à esquerda e nível fraco a moderado para flechas à direita; (4) a reprodutibilidade interavaliador apresentou nível moderado para as flechas escolióticas à direita e à esquerda; (5) não houve correlação significativa entre as flechas à direita e os ângulos Cobb para a direita e houve correlação fraca entre as flechas à esquerda e os ângulos Cobb a esquerda; (6) a repetibilidade e reprodutibilidade interavaliador manteve bons níveis de correlação independente do perfil nutricional avaliado, nos dois planos investigados. Conclui-se que o sistema Vert 3D apresentou adequados níveis de repetibilidade e reprodutibilidade interavaliador para a avaliação de crianças de todos os perfis nutricionais, podendo dessa forma, ser utilizado no acompanhamento clínico das curvaturas da coluna vertebral nos planos frontal e sagital. No entanto, até o presente momento não é possível utilizar esse sistema para o diagnóstico de alterações posturais, nem mesmo para estimar o ângulo de Cobb, já que não foram encontradas adequadas correlações e concordâncias com os exames radiográficos. Ainda, o sistema Vert 3D não tem a pretensão de substituir o exame radiológico, mas pode ser utilizado como uma importante ferramenta no fornecimento de informações adicionais à cerca do posicionamento da superfície do dorso, possibilitando ampliar o conhecimento da avaliação postural, visando um planejamento adequado de intervenções pelos profissionais da saúde. Além disso, com a utilização desse sistema, pode-se reduzir a exposição frequente aos Raios-X. / This master degree dissertation had the objctive of verify the concurrent validity, repeatability, reproducibility interrater, the sensitivity and the specificity of the Vert 3D system in the evaluation of frontal and sagittal curvatures in children with different nutritional profiles. Initially it was performed two systematic reviews of the literature with the purpose of investigate the existence of scientific evidence regarding the instruments of noninvasive evaluation of scoliosis, thoracic kyphosis and lumbar lordosis. Based on these systematic reviews it was possible to observe that, in general, the instruments showed satisfactory conditions for noninvasive evaluation of spinal curvatures. Furthermore, there seems to be a consensus in the literature about the applicability of noninvasive instruments, which are indicated for clinical monitoring, in order to reduce the frequent exposure to X-rays without, however, allowing the replacement of radiography. However, there is still a lack of studies in literature with a strong scientific evidence Regarding the validation of noninvasive evaluation instruments of the spine, and for this reason, it was developed an original study in order to investigate aspects of the validation of the Vert 3D system. It was evaluated 115 children, who underwent panoramic radiography of the spine in sagittal and frontal planes, and five assessments with the Vert 3D system, by three trained raters. The results showed that the the Vert 3D system: (1) showed excellent levels of repeatability and reproducibility Interrater for angles of thoracic kyphosis and lumbar lordosis; (2) showed a weak correlation with the Cobb angle for thoracic kyphosis and moderate correlation for lumbar lordosis; (3) to evaluate the frontal plane the Vert 3D system presented a moderate level of repeatability for arrows to the left and weak to moderate for arrows to the right; (4) the interrater reproducibility showed a moderate level to the scoliosis arrows to the right and left; (5) there was no significant correlation between the arrows to the right and Cobb angles to the right and there was a weak correlation between the arrows to the left and the left Cobb angles; (6) the repeatability and the interrater reproducibility maintained good levels of correlation independent of nutritional status evaluated in the two plans investigated. It is concluded that the Vert 3D system presented adequate levels of repeatability and Interrater reproducibility for the evaluation of children of all nutrient profiles, and can this way it can be used in the clinical monitoring of spinal curvatures in the sagittal and frontal planes. However, until this moment it is not possible to use this system for the diagnosis of postural alterations, not even to estimate the Cobb angle, since were not found appropriate correlations and concordances with radiographs. Still , the Vert 3D system does not intend to replace the radiological examination, but can be used as an important tool in providing information about the positioning of the back surface, making it possible to enhance the knowledge about postural evaluation, seeking a proper planning of interventions by health care professionals. Furthermore, by using this system one can reduce frequent exposure to X-rays.
|
5 |
Validação de um sistema de escaneamento 3d para avaliação das curvaturas da coluna vertebral de crianças em diferentes perfis nutricionaisSedrez, Juliana Adami January 2013 (has links)
A presente dissertação de mestrado teve como objetivo verificar a validade concorrente, a repetibilidade, a reprodutibilidade interavaliador, a sensibilidade e a especificidade do sistema Vert 3D na avaliação das curvaturas frontais e sagitais de crianças com diferentes perfis nutricionais. Inicialmente foram realizadas duas revisões sistemáticas da literatura com o objetivo de investigar a existência de evidências científicas sobre os instrumentos de avaliação não invasiva da escoliose, cifose torácica e lordose lombar. A partir dessas revisões sistemáticas foi possível observar que, em geral, os instrumentos apresentaram condições satisfatórias para a avaliação não invasiva das curvaturas da coluna vertebral. Além disso, parece haver consenso na literatura sobre a aplicabilidade dos instrumentos não invasivos, os quais são indicados para o acompanhamento clínico, com o objetivo de reduzir a exposição frequente aos Raios-X sem, no entanto, possibilitar a substituição da radiografia. No entanto, ainda há carência na literatura de estudos com forte evidência científica no que tange a validação dos instrumentos não invasivos de avaliação da coluna vertebral, e por esse motivo, desenvolveu-se um estudo original com a finalidade de investigar os aspectos de validação do sistema Vert 3D. Foram avaliadas 115 crianças, as quais foram submetidas à radiografia panorâmica da coluna vertebral sagital e frontal, além de cinco avaliações com o sistema Vert 3D, por três avaliadores treinados. Os resultados demonstraram que o sistema Vert 3D: (1) apresentou excelentes níveis de repetibilidade e reprodutibilidade interavaliador para os ângulos de cifose torácica e lordose lombar; (2) apresentou fraca correlação com o ângulo de Cobb para cifose torácica e correlação moderada para lordose lombar; (3) para avaliação do plano frontal, o sistema Vert 3D apresentou nível moderado de repetibilidade para flechas à esquerda e nível fraco a moderado para flechas à direita; (4) a reprodutibilidade interavaliador apresentou nível moderado para as flechas escolióticas à direita e à esquerda; (5) não houve correlação significativa entre as flechas à direita e os ângulos Cobb para a direita e houve correlação fraca entre as flechas à esquerda e os ângulos Cobb a esquerda; (6) a repetibilidade e reprodutibilidade interavaliador manteve bons níveis de correlação independente do perfil nutricional avaliado, nos dois planos investigados. Conclui-se que o sistema Vert 3D apresentou adequados níveis de repetibilidade e reprodutibilidade interavaliador para a avaliação de crianças de todos os perfis nutricionais, podendo dessa forma, ser utilizado no acompanhamento clínico das curvaturas da coluna vertebral nos planos frontal e sagital. No entanto, até o presente momento não é possível utilizar esse sistema para o diagnóstico de alterações posturais, nem mesmo para estimar o ângulo de Cobb, já que não foram encontradas adequadas correlações e concordâncias com os exames radiográficos. Ainda, o sistema Vert 3D não tem a pretensão de substituir o exame radiológico, mas pode ser utilizado como uma importante ferramenta no fornecimento de informações adicionais à cerca do posicionamento da superfície do dorso, possibilitando ampliar o conhecimento da avaliação postural, visando um planejamento adequado de intervenções pelos profissionais da saúde. Além disso, com a utilização desse sistema, pode-se reduzir a exposição frequente aos Raios-X. / This master degree dissertation had the objctive of verify the concurrent validity, repeatability, reproducibility interrater, the sensitivity and the specificity of the Vert 3D system in the evaluation of frontal and sagittal curvatures in children with different nutritional profiles. Initially it was performed two systematic reviews of the literature with the purpose of investigate the existence of scientific evidence regarding the instruments of noninvasive evaluation of scoliosis, thoracic kyphosis and lumbar lordosis. Based on these systematic reviews it was possible to observe that, in general, the instruments showed satisfactory conditions for noninvasive evaluation of spinal curvatures. Furthermore, there seems to be a consensus in the literature about the applicability of noninvasive instruments, which are indicated for clinical monitoring, in order to reduce the frequent exposure to X-rays without, however, allowing the replacement of radiography. However, there is still a lack of studies in literature with a strong scientific evidence Regarding the validation of noninvasive evaluation instruments of the spine, and for this reason, it was developed an original study in order to investigate aspects of the validation of the Vert 3D system. It was evaluated 115 children, who underwent panoramic radiography of the spine in sagittal and frontal planes, and five assessments with the Vert 3D system, by three trained raters. The results showed that the the Vert 3D system: (1) showed excellent levels of repeatability and reproducibility Interrater for angles of thoracic kyphosis and lumbar lordosis; (2) showed a weak correlation with the Cobb angle for thoracic kyphosis and moderate correlation for lumbar lordosis; (3) to evaluate the frontal plane the Vert 3D system presented a moderate level of repeatability for arrows to the left and weak to moderate for arrows to the right; (4) the interrater reproducibility showed a moderate level to the scoliosis arrows to the right and left; (5) there was no significant correlation between the arrows to the right and Cobb angles to the right and there was a weak correlation between the arrows to the left and the left Cobb angles; (6) the repeatability and the interrater reproducibility maintained good levels of correlation independent of nutritional status evaluated in the two plans investigated. It is concluded that the Vert 3D system presented adequate levels of repeatability and Interrater reproducibility for the evaluation of children of all nutrient profiles, and can this way it can be used in the clinical monitoring of spinal curvatures in the sagittal and frontal planes. However, until this moment it is not possible to use this system for the diagnosis of postural alterations, not even to estimate the Cobb angle, since were not found appropriate correlations and concordances with radiographs. Still , the Vert 3D system does not intend to replace the radiological examination, but can be used as an important tool in providing information about the positioning of the back surface, making it possible to enhance the knowledge about postural evaluation, seeking a proper planning of interventions by health care professionals. Furthermore, by using this system one can reduce frequent exposure to X-rays.
|
6 |
Análise de um sistema de escaneamento 3D para avaliação das curvaturas sagitais e frontais da coluna vertebral de indivíduos de diferentes faixas etáriasMarques, Mariana Tonietto January 2013 (has links)
O padrão ouro para a avaliação e o acompanhamento de desvios posturais é o exame radiológico. No entanto, a exposição à radiação ionizante aumenta o risco do desenvolvimento de câncer. Nessa perspectiva, se faz necessário o uso de métodos não invasivos com validade, repetibilidade e reprodutibilidade para mensurar os desvios posturais e acompanhar a sua progressão. Dessa maneira, o intuito do presente estudo foi verificar se o sistema Vert 3D fornece informações válidas referentes aos desvios posturais nos planos frontal e sagital de indivíduos de diferentes faixas etárias. Além disso, verificar a repetibilidade e a reprodutibilidade interavaliador do sistema Vert 3D nos planos sagital e frontal. Foi avaliada a postura sagital e frontal de 89 crianças de ambos os sexos e diferentes faixas etárias. A avaliação consistiu de duas etapas: exame radiológico e sistema Vert 3D. A primeira etapa foi realizada por um operador de raios X experiente e, a partir das imagens geradas, foram calculados os ângulos de Cobb nos planos sagital e frontal. A segunda etapa foi executada no mesmo dia por três avaliadores treinados no método e foram calculados os ângulos de deformidade do Vert 3D nos planos sagital e frontal e as flechas de escoliose do Vert 3D. O primeiro avaliador efetuou duas análises sucessivas, o segundo avaliador efetuou em seguida outras duas análises sucessivas e o terceiro avaliador efetuou a seguir uma única análise. Foram comparados e correlacionados os dados sucessivos de um mesmo avaliador para verificar a repetibilidade, os dados de diferentes avaliadores para verificar a reprodutibilidade interavaliador e entre os dados dos dois sistemas para verificar a validade do sistema Vert 3D. Para a repetibilidade no plano sagital, não houve diferença (p>0,05) e as correlações foram excelentes (ICC≥0,750, p<0,05). Para a reprodutibilidade interavaliador no plano sagital, não houve diferença (p>0,05) e as correlações foram satisfatórias (0,400<ICC<0,750, p<0,05) para a cifose de indivíduos de 6 a 10 anos e 16 a 18 anos e para a lordose de indivíduos de 11 a 15 anos e excelentes (ICC≥0,750, p<0,05) para a cifose de indivíduos de 11 a 15 anos e para a lordose de indivíduos de 6 a 10 e de 16 a 18 anos. E para a validade no plano sagital, houve diferença (p<0,05) e as correlações entre os ângulos de deformidade do Vert 3D (cifose e lordose) e os ângulos de Cobb (cifose e lordose) foram moderadas (0,400<r<0,699, p<0,05) para a cifose de indivíduos de 11 a 18 anos e para a lordose de indivíduos de 6 a 18 anos. Para a repetibilidade no plano frontal, não houve diferença (p>0,05) e as correlações foram satisfatórias (0,400<ICC<0,750, p<0,05) a excelentes (ICC≥0,750, p<0,05) para as flechas de escoliose do Vert 3D de indivíduos de 6 a 18 anos e para os ângulos de deformidade do Vert 3D (escoliose) de indivíduos de 11 a 18 anos. Para a reprodutibilidade interavaliador, não houve diferença (p>0,05) e as correlações foram satisfatórias (0,400<ICC<0,750, p<0,05) para as flechas de escoliose do Vert 3D de indivíduos de 6 a 18 anos e para os ângulos de indivíduos de 11 a 18 anos. E para a validade no plano frontal, houve diferença (p<0,05) entre os ângulos dos dois sistemas e as correlações foram moderadas (0,400<rho< 0,699, p<0,05) em relação à média das flechas de escoliose do Vert 3D à esquerda e à média dos ângulos de deformidade do Vert 3D à esquerda. Tendo em vista os resultados para repetibilidade e reprodutibilidade do Vert 3D nos planos sagital e frontal, o sistema pode ser utilizado para o acompanhamento das posturas sagital e frontal de indivíduos de 6 a 18 anos, a partir dos ângulos de deformidade do Vert 3D (cifose e lordose) e das flechas de escoliose do Vert 3D. Além disso, pode ser utilizado para o acompanhamento da postura frontal de indivíduos de 11 a 18 anos, a partir dos ângulos de deformidade do Vert 3D (escoliose). No entanto, na ausência de validade em relação ao padrão ouro, esse instrumento não pode ser utilizado para fins de avaliação dos ângulos de Cobb (cifose, lordose e escoliose). / The gold standard for the assessment and monitoring of postural deviations is the radiological examination. However, exposure to X-rays increases the risk to develop cancer. At this view, it is necessary the use of valid, repeatable and reproducible non-invasive methods to measure and monitor the progression of the postural deviations. Thus, the aim of this study was to verify if the Vert 3D system provides valid information regarding the postural deviations in frontal and sagittal planes of individuals of different age groups. Also, check the repeatability and inter-rater reliability of the Vert 3D system in sagittal and frontal planes. We evaluated the sagittal and frontal posture of 89 children of both sexes and different age groups. The evaluation consisted of two steps: radiological examination and Vert 3D system. The first step was performed by an experienced X-rays operator and from X-ray images were calculated Cobb angles in the sagittal and frontal planes. The second step was performed on the same day by three trained in the method evaluators. Was calculated the Vert 3D deformity angles in the sagittal and frontal planes and the Vert 3D scoliosis arrows. The first evaluator carried out two successive analyzes, the second evaluator then made two other successive analyzes and after the third evaluator made a single analysis. Were compared and correlated successive data of the each evaluator to verify repeatability, data from different evaluators to verify inter-rater reliability reproducibility and data from each system to verify the validity of Vert 3D system. For repeatability the in sagittal plane, was no difference (p>0.05) and the correlations were excellent (ICC≥0.750, p<0.05). For inter-rater reliability in the sagittal plane, was no difference (p>0.05) and the correlations were satisfactory (0.400 <ICC<0.750, p<0.05) for kyphosis in 6-10 years old and 16-18 years old individuals and for lordosis of 11-15 years old individuals and fine (ICC≥0.750, p<0.05) for kyphosis in 11-15 years old individuals 11 to 15 years and for lordosis in 6-10 years old and 16-18 years old individuals. And for validity in the sagittal plane, was significant differences (p<0.05) and the correlations between Vert 3D deformity angles (kyphosis and lordosis) and Cobb angles (kyphosis and lordosis) were moderate (0.400<r<0.699, p<0.05) for kyphosis in 11-18 years old individuals and for lordosis in 6-18 years old individuals. For the repeatability in the frontal plane, was no difference (p>0.05) and the correlations were satisfactory (0.400<ICC<0.750, p <0.05) to excellent (ICC≥0.750, p <0.05) for Vert 3D scoliosis arrows in 6-18 years old individuals and for Vert 3D deformity angles (scoliosis) in 11-18 years old individuals 11-18 years. For inter-rater reliability, was no difference (p>0.05) and the correlations were satisfactory (0.400<ICC<0.750, p<0.05) for Vert 3D scoliosis arrows in 6- 18 years old individuals and Vert 3D deformity angles (scoliosis) in 11-18 years old individuals. And for validity in the frontal plane, was significant differences (p<0.05) between the angles of the two systems and the correlations were moderate (0.400<rho<0.699, p<0.05) to the mean of Vert 3D scoliosis left arrows and the mean of Vert 3D deformity left angles (scoliosis). Considering the results for repeatability and inter-rater reliability of Vert 3D in both planes, the system can be used for monitoring the sagittal and frontal postures of 6-18 years old individuals 6-18 years from Vert 3D deformity angles (kyphosis and lordosis) and from Vert 3D scoliosis arrows. Moreover, it can be used for monitoring the frontal posture of 11-18 years old individuals from Vert 3D deformity angles (scoliosis). However, in the absence of validity related to the gold standard, the Vert 3D system cannot be used for diagnosis of Cobb angles (kyphosis, scoliosis, lordosis).
|
7 |
Validação de um sistema de escaneamento 3d para avaliação das curvaturas da coluna vertebral de crianças em diferentes perfis nutricionaisSedrez, Juliana Adami January 2013 (has links)
A presente dissertação de mestrado teve como objetivo verificar a validade concorrente, a repetibilidade, a reprodutibilidade interavaliador, a sensibilidade e a especificidade do sistema Vert 3D na avaliação das curvaturas frontais e sagitais de crianças com diferentes perfis nutricionais. Inicialmente foram realizadas duas revisões sistemáticas da literatura com o objetivo de investigar a existência de evidências científicas sobre os instrumentos de avaliação não invasiva da escoliose, cifose torácica e lordose lombar. A partir dessas revisões sistemáticas foi possível observar que, em geral, os instrumentos apresentaram condições satisfatórias para a avaliação não invasiva das curvaturas da coluna vertebral. Além disso, parece haver consenso na literatura sobre a aplicabilidade dos instrumentos não invasivos, os quais são indicados para o acompanhamento clínico, com o objetivo de reduzir a exposição frequente aos Raios-X sem, no entanto, possibilitar a substituição da radiografia. No entanto, ainda há carência na literatura de estudos com forte evidência científica no que tange a validação dos instrumentos não invasivos de avaliação da coluna vertebral, e por esse motivo, desenvolveu-se um estudo original com a finalidade de investigar os aspectos de validação do sistema Vert 3D. Foram avaliadas 115 crianças, as quais foram submetidas à radiografia panorâmica da coluna vertebral sagital e frontal, além de cinco avaliações com o sistema Vert 3D, por três avaliadores treinados. Os resultados demonstraram que o sistema Vert 3D: (1) apresentou excelentes níveis de repetibilidade e reprodutibilidade interavaliador para os ângulos de cifose torácica e lordose lombar; (2) apresentou fraca correlação com o ângulo de Cobb para cifose torácica e correlação moderada para lordose lombar; (3) para avaliação do plano frontal, o sistema Vert 3D apresentou nível moderado de repetibilidade para flechas à esquerda e nível fraco a moderado para flechas à direita; (4) a reprodutibilidade interavaliador apresentou nível moderado para as flechas escolióticas à direita e à esquerda; (5) não houve correlação significativa entre as flechas à direita e os ângulos Cobb para a direita e houve correlação fraca entre as flechas à esquerda e os ângulos Cobb a esquerda; (6) a repetibilidade e reprodutibilidade interavaliador manteve bons níveis de correlação independente do perfil nutricional avaliado, nos dois planos investigados. Conclui-se que o sistema Vert 3D apresentou adequados níveis de repetibilidade e reprodutibilidade interavaliador para a avaliação de crianças de todos os perfis nutricionais, podendo dessa forma, ser utilizado no acompanhamento clínico das curvaturas da coluna vertebral nos planos frontal e sagital. No entanto, até o presente momento não é possível utilizar esse sistema para o diagnóstico de alterações posturais, nem mesmo para estimar o ângulo de Cobb, já que não foram encontradas adequadas correlações e concordâncias com os exames radiográficos. Ainda, o sistema Vert 3D não tem a pretensão de substituir o exame radiológico, mas pode ser utilizado como uma importante ferramenta no fornecimento de informações adicionais à cerca do posicionamento da superfície do dorso, possibilitando ampliar o conhecimento da avaliação postural, visando um planejamento adequado de intervenções pelos profissionais da saúde. Além disso, com a utilização desse sistema, pode-se reduzir a exposição frequente aos Raios-X. / This master degree dissertation had the objctive of verify the concurrent validity, repeatability, reproducibility interrater, the sensitivity and the specificity of the Vert 3D system in the evaluation of frontal and sagittal curvatures in children with different nutritional profiles. Initially it was performed two systematic reviews of the literature with the purpose of investigate the existence of scientific evidence regarding the instruments of noninvasive evaluation of scoliosis, thoracic kyphosis and lumbar lordosis. Based on these systematic reviews it was possible to observe that, in general, the instruments showed satisfactory conditions for noninvasive evaluation of spinal curvatures. Furthermore, there seems to be a consensus in the literature about the applicability of noninvasive instruments, which are indicated for clinical monitoring, in order to reduce the frequent exposure to X-rays without, however, allowing the replacement of radiography. However, there is still a lack of studies in literature with a strong scientific evidence Regarding the validation of noninvasive evaluation instruments of the spine, and for this reason, it was developed an original study in order to investigate aspects of the validation of the Vert 3D system. It was evaluated 115 children, who underwent panoramic radiography of the spine in sagittal and frontal planes, and five assessments with the Vert 3D system, by three trained raters. The results showed that the the Vert 3D system: (1) showed excellent levels of repeatability and reproducibility Interrater for angles of thoracic kyphosis and lumbar lordosis; (2) showed a weak correlation with the Cobb angle for thoracic kyphosis and moderate correlation for lumbar lordosis; (3) to evaluate the frontal plane the Vert 3D system presented a moderate level of repeatability for arrows to the left and weak to moderate for arrows to the right; (4) the interrater reproducibility showed a moderate level to the scoliosis arrows to the right and left; (5) there was no significant correlation between the arrows to the right and Cobb angles to the right and there was a weak correlation between the arrows to the left and the left Cobb angles; (6) the repeatability and the interrater reproducibility maintained good levels of correlation independent of nutritional status evaluated in the two plans investigated. It is concluded that the Vert 3D system presented adequate levels of repeatability and Interrater reproducibility for the evaluation of children of all nutrient profiles, and can this way it can be used in the clinical monitoring of spinal curvatures in the sagittal and frontal planes. However, until this moment it is not possible to use this system for the diagnosis of postural alterations, not even to estimate the Cobb angle, since were not found appropriate correlations and concordances with radiographs. Still , the Vert 3D system does not intend to replace the radiological examination, but can be used as an important tool in providing information about the positioning of the back surface, making it possible to enhance the knowledge about postural evaluation, seeking a proper planning of interventions by health care professionals. Furthermore, by using this system one can reduce frequent exposure to X-rays.
|
8 |
Adaptação Transcultural da MOTOR ASSESSMENT SCALE (MAS) para o Brasil e Análise das Propriedades de MedidaWANDERLEY, Elaine Lima Silva 09 July 2014 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-07-26T14:03:44Z
No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Dissertação para a colação 2.pdf: 2117716 bytes, checksum: 168ae5a81028b9ff3a4ce39ab1eb3edd (MD5) / Made available in DSpace on 2016-07-26T14:03:44Z (GMT). No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Dissertação para a colação 2.pdf: 2117716 bytes, checksum: 168ae5a81028b9ff3a4ce39ab1eb3edd (MD5)
Previous issue date: 2014-07-09 / CAPEs / O objetivo deste estudo foi realizar a adaptação transcultural da Motor Assessment Scale-MAS para o Brasil e analisar a confiabilidade (interexaminadores e teste-reteste), medida de erro (interexaminadores e teste-reteste) consistência interna e validade de construto. Além disso, foi realizada uma revisão sistemática para averiguar a validade dos instrumentos de mensuração do estado de saúde que avaliam a função motora após acidente vascular encefálico-AVE, disponíveis no Brasil. A revisão sistemática seguiu um protocolo pré-estabelecido e foi realizada por dois avaliadores independentes, considerando os estudos de propriedades de medida de instrumentos que avaliaram a função motora após AVE, resultado de adaptação cultural ou criação brasileira. A avaliação da qualidade metodológica foi realizada através do COnsensus-based Standards for the selection of health Measurements INstruments-COSMIN. O processo de adaptação transcultural da MAS foi realizado em 5 estágios: tradução, síntese das traduções, retrotradução, comitê de especialistas e pré-teste. A escala também foi submetida à opinião de Fisioterapeutas de diferentes estados do país, através de um estudo Delphi. A análise das propriedades de medida envolveu a participação de 100 indivíduos com diagnóstico clínico de AVE primário ou recorrente há no mínimo 30 dias, com presença de hemiparesia/hemiplegia, idade superior a 21 anos e ambos os sexos. A confiabilidade foi analisada através do coeficiente Kappa, a medida-de-erro através teste de plotagem de Bland & Altman e a consistência interna e a validade de construto foi verificadas através da análise Rasch. O resultado da revisão sistemática mostrou que todos os instrumentos disponíveis no Brasil para avaliação da função motora após AVE originaram-se em outros países e apresentaram uma metodologia inadequada seja no processo de adaptação transcultural ou na análise das propriedades de medida, tornando os resultados inconclusivos quanto à validade desses instrumentos. O adequado processo de adaptação transcultural e o estudo Delphi garantiram a equivalência semântica e adequação cultural da MAS para o Brasil. Os valores dos coeficientes de Kappa para as confiabilidades interexaminadores e teste-reteste foram 0,73 (variando nos itens de 0,79 a 1,00) e 0,82 (variando nos itens de 0,86 a 1,00), respectivamente. O teste de Bland Altman demonstrou adequada concordância. A análise Rasch demonstrou ausência de efeitos “solo” e “teto” (4% e 9%, respectivamente) e a capacidade do instrumento de dividir a amostra em mais de quatro níveis de habilidade. O item 4 “Sentado para de pé” apresentou padrão errático (MnSq infit=1,44; z=2,6). No entanto, a presença de apenas um item errático não afetou a unidimensionalidade do instrumento, o qual apresentou adequadas consistência interna e validade de construto. Desta forma, a MAS-Brasil constituiu-se em um instrumento adaptado e válido e poderá ser usado em contextos clínicos e nas pesquisas em indivíduos após AVE. / The objective of this study was to perform the cross-cultural adaptation of MAS for Brazil and analyse the reliability (inter-rater and test-retest), measurement error (inter-rater and test-retest), internal consistency and construct validity. Furthermore, was performed a systematic review to determine the validity of the health measurements instruments that assess motor function after stroke, available in Brazil. The systematic review followed a pre-established protocol and was performed by two independent evaluators considering studies on measurement properties of instruments that assessed motor function after stroke that resulted of cultural adaptation or Brazilian creation. The assessment of methodological quality was performed using the COnsensus-based Standards for the selection of health Measurements Instruments-COSMIN. The process of cross-cultural adaptation of the MAS was done in 5 stages following standardized guidelines: translation, synthesis of translations, back translation, experts’ committee review and pretesting. The scale was also submitted to the opinion of Physiotherapists of different states of the country, through a Delphi study. The analysis of measurement properties involved the participation of 100 individuals with a clinical diagnosis of primary or recurrent stroke for at least 30 days, with the presence of hemiparesis / hemiplegia, age greater than 21 years and both sexes. The reliability was analysed through the Kappa coefficient, the measurement error through Bland & Altman plots test and the internal consistency and construct validity were verified by the Rasch analysis. The adequate process of cultural adaptation and the Delphi study ensured the semantic and cultural appropriateness of MAS to Brazil. The Kappa coefficient values for the reliability inter-examiners and test-retest was 0.73 (varying in items 0.79 and 1.00) and 0.82 (varying in items 0.86 and 1.00), respectively. The Bland Altman test demonstrated adequate agreement. As for the analysis of the measurement properties, the Rasch analysis demonstrated absence of the “floor” and “ceiling” effects (4% and 9%, respectively) and the capacity of the instrument to divide the sample into more than four levels of ability. The item 4 “Sitting to standing” showed erratic standard (MnSq infit=1.44; z=2.6). Although, the presence of only one erratic item did not affect the unidimensionality of the instrument, which showed adequate internal consistence and construct validity. This way, the MAS-Brasil was constituted as an adapted and valid instrument and can be used in clinical contexts and in researches in patients after stroke.
|
9 |
Aplicabilidade, validação e reprodutibilidade do Spinal Cord Independence Measure version III (SCIM III) nos pacientes com paraparesia espástica / Applicability, validation and reproducibility of the Spinal Cord Independence Measure version III (SCIM III) in patients with spastic paraplegiaCamila de Almeida 18 December 2014 (has links)
Objetivo: verificar a aplicabilidade, reprodutibilidade e validade do SCIM III nos pacientes com paraparesia espástica. Método: estudo transversal incluindo 30 sujeitos (66% mulheres; 41,5±14,7 anos) com paraparesia espástica de etiologia genética, infecciosa ou a esclarecer que foram avaliados pela análise computadorizada da marcha, versão brasileira da SCIM III (0-100 pontos), MIF (18-126 pontos), por 2 examinadores (A e B) no mesmo dia e 1 semana depois (A). Resultados: o coeficiente de correlação intraclasse (CCI) para o uso da SCIM III indicou boa reprodutibilidade intra e inter-examinadores (CCI=0,9). A correlação de Spearman entre a SCIM III e a parte motora da MIF foi considerada adequada e estatisticamente significante (Spearman=0,6; p=0,001). A correlação entre as subescalas da SCIM III e os domínios da MIF foi considerada forte e significante para auto-cuidado (Spearman=0,8; p0,001) e moderada para transferências (Spearman=0,6; p=0,0005) e locomoção (Spearman=0,6; p=0,0006). A subescala mobilidade da SCIM III mostrou correlação positiva e significante para cadência (Spearman=0,8; p0,001), velocidade da marcha (Spearman=0,7; p0,001) e comprimento do passo (Spearman=0,6; p0,001). Conclusões: A SCIM III é um instrumento de avaliação funcional reprodutível intra e inter examinadores e capaz de avaliar o nível de independência dos indivíduos com paraparesia espástica. O SCIM III é mais sensível que a MIF, especialmente para pacientes com maior independência. Cadência, velocidade de marcha e comprimento do passo se correlacionaram com a subescala mobilidade / Purpose: to verify the applicability, reproducibility, and validity of the SCIM III patients with non-traumatic spastic paraplegia. Method: The cross-sectional study included 30 subjects (66% females; 41.5 ± 14.7 y) older with spastic paraparesis of any etiology were assessment by computerized gait analysis and with the Brazilian versions of SCIM III (0-100 points), FIM (18-126 points) by 2raters (A and B) at the same day and 1 week later (A). Results: The intraclass correlation coefficient (ICC) for the use of SCIM III indicated good intra and inter-evaluator reproducibility (ICC = 0.9). Correlation between the SCIM III and the motor FIM was appropriate (Spearman=0.6; p0.001). SCIM III subscales and the FIM domains correlated strongly for self-care (Spearman=0.8; p0.001), moderately for transfers (Spearman=0.6; p=0.0005) and locomotion (Spearman=0.6; p=0.0006). SCIM III mobility subscale positively correlated with the cadence (Spearman=0.8; p0.01), gait speed (Spearman=0.7; p0.01), and step length (Spearman=0.6;p0.01). Conclusions: SCIM III is a reproducible functional assessment instrument and capable of evaluating the level of independence of the individual with spastic paraplegia. The SCIM III is more sensitive than the FIM for non-traumatic spastic paraplegic patients with higher levels of independence. Linear gait parameters correlated with its mobility subscale.
|
10 |
Adaptação cultural e validação do Freiburg Life Quality Assessment (FLQA) - Wound para a língua portuguesa do Brasil / Cultural adaptation and validation of Freiburg Life Quality Assessment (FLQA) - wound into portuguese of BrazilDomingues, Elaine Aparecida Rocha, 1985- 23 August 2018 (has links)
Orientador: Neusa Maria Costa Alexandre / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-23T00:34:52Z (GMT). No. of bitstreams: 1
Domingues_ElaineAparecidaRocha_M.pdf: 4577350 bytes, checksum: f80761f458c94b4e1cb0e338f6cfcf63 (MD5)
Previous issue date: 2013 / Resumo: Feridas crônicas são aquelas que cicatrizam em um período superior a seis semanas e acometem milhões de indivíduos no mundo. A demora na cicatrização e o elevado índice de recidivas afetam a qualidade de vida do indivíduo com ferida. No Brasil há uma escassez de questionários específicos para analisar a qualidade de vida de pessoas com feridas de qualquer etiologia. Dessa forma, o presente estudo apresenta como objetivo adaptar o "Freiburg Life Quality Assessment - Wound" para a língua portuguesa do Brasil e avaliar suas propriedades psicométricas. A adaptação cultural foi realizada seguindo as etapas de tradução, síntese das traduções, retro-tradução, comitê de especialista, préteste e grupo focal. Participaram da pesquisa 200 indivíduos com idade média de 59 anos (±14,0), predominaram o sexo feminino (62%) e com maior frequência no ensino fundamental (48,2%) e com úlcera de etiologia venosa (45%). A confiabilidade foi avaliada pela consistência interna e estabilidade. O alfa de Cronbach foi de 0,86 e o teste reteste, apresentou uma elevada correlação de 0,92. A validade convergente foi obtida por meio da correlação dos domínios do índice de Qualidade de Vida Ferrans e Powers- versão feridas (IQVFP- VF) e com a pontuação de qualidade de vida da escala visual analógica (EVA). Os domínios do IQVFP- VF apresentaram correlações significativas, com valores entre -0,24 a - 0,48. Em relação a correlação com o escore de qualidade de vida da EVA o valor obtido foi de -0,38. Os resultados indicaram que a versão adaptada apresentou medidas psicométricas confiáveis e válidas para a população com feridas crônicas da cultura brasileira / Abstract: Chronic wounds are those that heal over six weeks period and affect million people all over the world. The healing delay and the high number of reappearance affect the quality of Life of the person with wounds. There is a lack of specific questionnaires in Brazil to analyze the quality of Life of people with wounds of any etiology. Thus, this study presents as object the adaptation of the "Freiburg Life Quality Assessment - Wound" to Brazilian Portuguese and assess its psychometric properties. The cultural adaptation was done following the translation steps, the summary of the translations, retro-translation, experts committee, pre-test and focal group. 200 people took part in the survey with an average of 59 years old (±14,0), the female gender prevailed with (62%) and with high school (48,2%) and with venous ulcers (45%). The reliability was evaluated for stability and internal consistency. The alpha of cronbach was of 0,86, and the test retest, presented a high correlation of 0,92. The convergent validity was obtained through the correlation of the domain of the Quality of Life index Ferrans and Powers- wounds version (IQVFP-VF) and with scores of quality of life visual analog scale (VAS). The domains IQVFP-VF showed significant correlations, with value between -0.24 to -0.48. Regarding the correlation with quality of life scores of the VAS value was - 0.38. The results indicated that the adapted version presented reliable and valid psychometrics measurements to the population with chronic wounds of the Brazilian culture / Mestrado / Enfermagem e Trabalho / Mestra em Ciências da Saúde
|
Page generated in 0.089 seconds