• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 7
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 30
  • 30
  • 14
  • 9
  • 9
  • 7
  • 7
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Växtväggar som funktionellt system inomhus : En studie av kyleffektbehov, inomhusmiljö och kostnadsbesparing med hjälp av växtväggen som finns i byggnaden på Teknikringen 78A / Plant walls as a functional indoor system : A study of cooling effect, indoor environment and cost cutting by using the plantwall in the building at Teknikringen 78A

Francis, Wanda, Rafinia, Niusha January 2017 (has links)
Växtväggen i byggnaden på Teknikringen 78A var en utgångspunkt i detta examensarbete där ett samarbete mellan KTH, Vertical plants system och examenstagare skedde. Arbetet gick ut på att undersöka växtväggen och studera olika påverkande faktorer. I dagsläget är det väldigt många faktorer och grundkällor som påverkan miljön vi lever i, inom byggbranschen sker dagligen utsläpp av farliga föroreningar som påverkar miljön och försvagar naturen. Av detta skäl valdes en miljövänlig alternativ lösning att studeras, nämligen växtväggar inomhus. För att ge en enkel förståelse för läsaren av rapporten har arbetet börjats med en internationell jämförelse mellan tre ledande företag inom området för växtväggar vars unika system undersöktes. Dessa tre var Nedlaw, Naava och Vertical Plants System AB. Därefter studerades olika miljöcertifieringssystem från SGBC och valet hamnade på BREEAM-SE. BREEAM-SE ett system som behandlar frågor inom såväl energianvändningen och inomhusluftkvalitet som är två betydande faktorer som påverkas av en växtvägg. Studien gick ut på att undersöka olika indikatorer inom områden och växtväggens förmåga att bidra vid poänggivning vid certifiering av en byggnad. Vidare gjordes en djupgående studie på kyleffektbehovet i byggnaden på Teknikringen 78A med olika mätvärde från företaget som monterade växtväggen i byggnaden samt fastighetsägaren Akademiska hus. Med hjälp av mätvärden kunde en slutsats dras om att växtväggar verkligen har ett märkbart kyleffektbidrag i byggnaden som i sin tur medförde en sänkning av kyleffektbehovet med minst ca 10% utan fläkt och ca 20% med fläkt. Därtill presenterades resonemanget om sänkning av ventilationsrörens dimension i byggnaden för att undersöka om man kan få ut ekonomiska- och miljöbesparingar med hjälp av en växtvägg eller inte. Resultatet visade att man kan spara upp till 36%. Slutligen utfördes en studie på alla för- och nackdelar av växtväggar inomhus med huvudfokus på växternas miljö- och hälsoeffekt i allmänhet. Detta gjordes mot bakgrunden att det faktiskt saknas tillgång till en detaljerad information och kunskap om växtväggar trots stor efterfråga i marknaden. Resultatet av studien visade att växter i sig innehåller många fördelar på det fysiska och psykiska hälsan, miljön och på samhället i stort. Tillika visade det sig att en växtvägg uppfyller en betydande estetisk funktion i en lokal. Rapporten avslutades med en sammanställning av alla resultat kring de olika delarna som presenterades i arbetet. Slutligen visade det sig att en växtvägg är en livslång investering på hälsan och miljön som bör beaktas oftare och bli större inom en bransch som denna då bygg står för utsläpp av många miljögifter. / The plant wall in the building at Teknikringen 78A was a starting point for this project, where collaboration between KTH, Vertical plants and examiners took place. The main focus was about exploring the plant wall and studying various influencing factors. There are many factors and sources that affect the environment we live in. Within the construction industry, daily emissions of hazardous pollutants affect the environment and diminish nature. For this reason, an environmentally friendly alternative solution like indoor plant walls was chosen to be studied. To provide a simple understanding for the reader of this report, work has begun with an international comparison of three leading companies in the field of plant walls whose unique systems were investigated. These three were Nedlaw, Naava and Vertical Plants System AB. Thereafter, various environmental certification systems were studied from the SGBC and the choice ended at BREEAM-SE. BREEAM-SE is a system that treats areas such as energy and indoor air quality issues, which are two significant factors influenced by a plant wall. The study was about investigating different indicators in areas and the plant wall's ability to contribute to scoring for the certification of a building. In addition, a thorough study of the cooling efficiency requirement was made in the building at Teknikringen 78A with different measurement values from the company that mounted the plant wall in the building and the property owner Akademiska hus. Using measurements, a conclusion could be drawn that plant walls really have a noticeable cooling effect contribution in the building, which in turn resulted in a reduction of the cooling efficiency requirement by at least about 10% without fan and about 20% with fan. In addition, the reasoning was presented about reducing the ventilation pipes dimension in the building to investigate whether or not to obtain economic and environmental savings using a plant wall. The result showed that you can save up to 36%. Finally, a study was conducted on all the benefits and cons of indoor plant walls, with focus on the environmental and health effects of the plants in general. This was done by the fact that there is actually no access to detailed information and knowledge of plant walls despite high demand in the market. The result of the study showed that plants in themselves contain many benefits to physical and mental health, the environment and society. Additionally, it appeared that a plant wall fulfills a significant aesthetic function in a local area. This report was completed with a summary of all results about the various parts presented above. Finally, it turned out that a plant wall is a lifelong investment in health and the environment and should be considered more often and become larger in an industry like this, since buildings branch is a brunch were a lot of emissions released into the environment.
22

Full-scale experimental characterization of a non-isothermal realistic air jet for building ventilation : Local interaction effects, moisture transport and condensation prediction / Caractérisation expérimentale d'un jet d'air anisotherme réaliste pour la ventilation du bâtiment : L'interaction du local, le transport d'humidité et la condensation

Nguyen, Chi Kien 25 October 2018 (has links)
La compréhension de la distribution de l'air intérieur accompagné du transfert couplé "chaleur-air-humidité" est essentielle à la conception des systèmes de ventilation des bâtiments. Parmi les méthodes de distribution d'air intérieur, la ventilation par mélange est l'une des plus couramment utilisées, dont la performance est déterminée par celle du jet d'air injecté. Au cours des dernières décennies, bien que de nombreuses recherches aient été menées sur les études des jets d'air, la majorité de ces études se sont concentrées sur une disposition symétrique des bouches de soufflage et d’extraction par rapport à la géométrie du local. En outre, les études traitant du transfert couplé "chaleur-air-humidité", qui inclut le phénomène de condensation sur la surface interne du local, sont encore limités dans la littérature. Ainsi, ce travail se concentre sur la problématique suivante : Quel est le comportement d'un jet d'air réaliste sous des effets d'interaction et comment caractériser de tels jets d'air ? Dans des conditions d'intérieur réalistes favorisant la condensation sur une surface froide, serait-il possible de quantifier le débit massique de condensation ? Les deux études sont expérimentées dans la cellule d’essais MINIBAT à l’échelle 1. La première partie consiste à caractériser un jet d'air turbulent au plafond dans une configuration d’écoulement intérieur réaliste. Les résultats expérimentaux montrent les effets d'interaction visibles des éléments architecturaux de la pièce sur le comportement du jet d'air tels que la déviation de la trajectoire du jet ainsi que la déformation des profils du jet. Les principales caractéristiques du jet, telles que le taux d’expansion, la décroissance de vitesse et de température, sont quantifiées. Une méthode graphique basée sur un indicateur de déformation est proposée pour quantifier la déformation des profils transversaux du jet.La deuxième partie de ce travail traite le phénomène de condensation sur une surface vitrée en reproduisant les conditions hivernales dans la cellule d’essais. L’apparition de la condensation et son mécanisme de croissance sont observés à l'aide d'une technique de macrophotographie. Le post-traitement de l'image permet d'estimer le débit de condensation. Les comparaisons entre les résultats expérimentaux et théoriques montrent un certain accord, ce qui pourrait valider la faisabilité des techniques d'imagerie dans les études de condensation à l’échelle 1. Des données expérimentales détaillées accompagnées de conditions aux limites bien connues issues de ce travail pourraient servir de test de benchmark pour la validation des modèles CFD, en particulier pour les configurations d’écoulement asymétrique, avec la présence de la condensation. / Understanding room air distribution with coupled heat-air-moisture transport is essential to the design of building ventilation systems. In the past decades, although numerous research have been undertaken on air jet studies, there are still some issues that deserve a consideration. In fact, the majority of these studies focused on a symmetric arrangement of supply and exhaust air outlets with respect the room geometry. Besides, studies dealing with room coupled heat-air-moisture transport, which includes the condensation phenomenon on the room inner surface, are generally lacking in the literature. Hence, this work focuses on the following problematic: What is the behavior of a realistic air jet under interaction effects and how to characterize such air jets? In realistic indoor conditions promoting condensation on cold surface, would we be able to quantify the condensate mass flow rate? The two studies are experimentally investigated in the full-scale MINIBAT controlled test cell. The first part consists in characterizing a ceiling turbulent air jet in a realistic indoor airflow configuration. The experimental results show visible interaction effects of the room architectural elements on the air jet behavior: they have deviated the jet trajectory as well as deformed the jet cross-sectional shape. The jet main characteristics such as the spread rate, the velocity and temperature decay are quantified. A graphical-based method is proposed to quantify the jet shape deformation using a so-called deformation indicator. The second part of this work treats the phenomenon of moisture condensation on a glazing surface by reproducing a winter condition within the test cell. The condensation appearance and its growth mechanism are observed using a macro-photography technique. The image post-processing enabled to estimate the condensation rate. Comparisons between experimental and theoretical results show some agreement, which could validate the feasibility of imaging techniques in full-scale condensation studies.Detailed experimental data accompanied by well-known boundary conditions from this work could serve as a benchmark test for CFD models validation, in particular for asymmetric airflow configurations, with the presence of the condensation phenomenon.
23

Urban regeneration: Urban renewal through eco-systemic design

Cottle, Louis E 03 December 2003 (has links)
The systemic relationship between the human entity and its environment, under the constraint of its function, were used as the perfect example to design and create the systemic relationship of an urban regenerative building with its economical, environmental and social context in the Inner City of Pretoria. / Dissertation (MArch (Prof))--University of Pretoria, 2005. / Architecture / unrestricted
24

Požadavky na zadávací dokumentaci veřejných zakázek na stavební práce / Tender Documentation Requirements of Public Works Contracts

Seidlová, Andrea January 2014 (has links)
This thesis focuses on the issues related to the requirements of the contracting authority contained in the tender documents of public works contracts. In the first part, the basic concepts of public procurement are explained, where most attention is devoted to particular tender documents. The second part deals with the situation of public procurement in the Czech Republic, during the years following the opinion of the newly released energy efficient buildings. A case study is used to determine whether the use of economic net present value (NPV), as the evaluation criteria for the selected public order.
25

Självdrag eller FTX? : En jämförelse av ventilationssystem / Self-Exhaust Ventilation or Supply and Exhaust Ventilation ? : A Comparison of Ventilation Systems

Ali Mahmood, Chro, Yousefi, Leyla January 2023 (has links)
SammanfattningIntroduktion: Sedan år 2000 har antalet byggnader i Sverige ökat kraftigt. Enligt Statiska centralbyrån (SCB) fanns över 5 miljoner bostäder i Sverige i slutet av år 2021. Av dessa bostäder är cirka 42 % villor, 51 % flerbostadshus och resterande är lägenheter i specialbostäder. Energiförbrukningen i småhus har ökat med cirka 22% sedan 1970-talet, främst på grund av ökad användning av cirkulationspumpar, golvvärme och ventilation. Detta har resulterat i ökad miljöpåverkan från byggsektorn. Effektivisering av ventilationssystem har varit ett fokusområde under lång tid, eftersom användningsfasen av ventilationssystemen har visat sig ha hög energianvändning och stor miljöpåverkan. En studie visar att VVS-systemen påverkar miljön både vid tillverknings- och användningsfasen. Dessutom har nya lågenergihus en högre miljöpåverkan i byggfasen på grund av användningen av mer material för att minska driftanvändningen. Valet av ventilationssystem är avgörande för villor, eftersom ett effektivt ventilationssystem inte bara förbättrar inomhusluften utan också minskar risken för hälsoproblem som kan uppstå vid otillräcklig ventilation. Nyckelord: Livscykelkostnad, LCC, Ventilationssystem, Självdragssystem, FTX-system, VIP-Energy, Från- och tilluftssystem, Värmeåtervinning. Syfte: Syftet med examensarbetet är att visa att valet av ventilationssystem har betydelse för minskad klimatpåverkan vid tillverknings- och användningsfasen under 30 års tid. Mål: Målet är att ta fram vilket av självdragsventilation och från- och tilluftssystem med värmeåtervinning som är mest ekonomiskt och ger lägst klimatpåverkan baserat på ett livscykelperspektiv på ett småhus under en kalkylperiod på 30 år. Frågeställningar: Vilken av självdrag och FTX är mest effektivt med tanke på energiförbrukningen under tillverknings- och användningsfasen?Hur påverkar självdrag respektive FTX-systemet uppvärmningskostnaderna för ett småhus under förutsättning att uppvärmningen sker med fjärrvärme?Vilket av de två ventilationssystemen är mest ekonomisk lönsamt enligt en jämförande LCC, baserad på ett småhus med en kalkylperiod på 30 år?Vilket av ventilationssystemen orsakar störst klimatpåverkan? Metod: Metoden är en fallstudie där VIP-Energy används för att visa byggnadens energiförbrukning timme för timme under ett helt år. En LCC-beräkning utförs för att bestämma kostnaden för ventilationssystemet under dess livslängd, inklusive uppskattade underhållskostnader och nyinvesteringar. Slutsats: Baserat på energiförbrukningen under tillverknings- och användningsfasen är det mer effektivt att använda självdrag istället för ett FTX-system. Självdrag med vedeldning har ett lägre fjärrvärmebehov jämfört med FTX-systemet och ger därmed lägre årliga uppvärmningskostnader. Över en 30-årsperiod har självdragssystemet en lägre total livscykelkostnad än FTX-systemet. FTX-systemet har en högre elförbrukning och därmed en större påverkan på klimatet än självdragssystemet. / AbstractIntroduction: Since the year 2000, the number of buildings in Sweden has seen a significant increase. According to the Statistics Sweden (SCB), there were over 5 million dwellings in Sweden at the end of 2021. Out of these dwellings, approximately 42% are single-family houses, 51% are multi-family buildings, and the remaining is apartments in specialized housing. The energy consumption in single-family houses has increased by around 22% since the 1970’s, primarily due to the increased use of circulation pumps, underfloor heating, and ventilation. This has resulted in an increased environmental impact from the construction sector. Efficiency improvements in ventilation systems have been a longstanding focus due to the high energy consumption and significant environmental impact associated with their operational phase. A study reveals that HVAC systems impact the environment both during the manufacturing and the operational phases. Furthermore, new low-energy buildings have a higher environmental footprint during the construction phase due to the increased use of materials aimed at reducing operational energy consumption. The choice of a ventilation system is crucial for homes, as an efficient ventilation system not only improves indoor air quality but also reduces the risk of health problems that can arise from inadequate ventilation. Keywords: Life Cycle Cost, LCC, Ventilation System, Self-Exhaust Ventilation, Supply and Exhaust Ventilation, VIP-Energy, Supply and Exhaust Air System, Heat Recovery. Purpose: The purpose of the thesis is to demonstrate that the choice of ventilation system has a significant impact on reducing environmental emissions during the manufacturing and operational phases over a 30-year period. Goal: The objective is to determine which of self-exhaust ventilation and supply and exhaust ventilation with heat recovery is the most cost-effective and has the lowest climate impact based on a life-cycle perspective for a single-family building over a calculation period of 30 years.Questions: Which of self-exhaust ventilation and supply and exhaust ventilation is the most efficient in terms of energy consumption during the manufacturing and usage phases?How do self-exhaust ventilation and supply and exhaust ventilation affect the heating costs for a single-family building assuming that heating is provided through district heating?Which of the two ventilation systems is most economically viable according to a comparative Life Cycle Cost (LCC) analysis, based on a single-family building with a calculation period of 30 years?Which of the two ventilation systems causes the greatest climate impact?
26

Автоматизация акустического расчета вентиляционных систем в задачах проектирования для компании Стройтекпроект : магистерская диссертация / Automation of acoustic calculation of ventilation systems in design tasks for the Stroytechproekt company

Пестов, М. А., Pestov, M. A. January 2023 (has links)
Разработан плагин для акустического расчета вентиляционных систем, используемый для выполнения задач компании Стройтекпроект. Способность плагина определять октавный спектр вентиляционного шума в расчетных точках, уровень звукового давления на пути распространения шума по системе вентиляции, рассчитывать снижение уровня звукового давления на разных участках. / A plug-in for acoustic calculation of ventilation systems has been developed, which is used to perform the tasks of the Stroytekproekt company. The ability of the plug-in to determine the octave spectrum of ventilation noise at the calculated points, the sound pressure level on the path of noise propagation through the ventilation system, to calculate the decrease in the sound pressure level at different sites.
27

Design of Hospital Operating Room Ventilation using Computational Fluid Dynamics / Utforma operationssalars ventilationssystem med hjälp av beräkningsströmningsmekanik

Sadrizadeh, Sasan January 2016 (has links)
The history of surgery is nearly as old as the human race. Control of wound infection has always been an essential part of any surgical procedure, and is still an important challenge in hospital operating rooms today. For patients undergoing surgery there is always a risk that they will develop some kind of postoperative complication. It is widely accepted that airborne bacteria reaching a surgical site are mainly staphylococci released from the skin flora of the surgical staff in the operating room and that even a small fraction of those particles can initiate a severe infection at the surgical site.  Wound infections not only impose a tremendous burden on healthcare resources but also pose a major threat to the patient. Hospital-acquired infection ranks amongst the leading causes of death within the surgical patient population. A broad knowledge and understanding of sources and transport mechanisms of infectious particles may provide valuable possibilities to control and minimize postoperative infections. This thesis contributes to finding solutions, through analysis of such mechanisms for a range of ventilation designs together with investigation of other factors that can influence spread of infection in hospitals, particularly in operating rooms. The aim of this work is to apply the techniques of computational fluid dynamics in order to provide better understanding of air distribution strategies that may contribute to infection control in operating room and ward environments of hospitals, so that levels of bacteria-carrying particles in the air can be reduced while thermal comfort and air quality are improved.  A range of airflow ventilation principles including fully mixed, laminar and hybrid strategies were studied. Airflow, particle and tracer gas simulations were performed to examine contaminant removal and air change effectiveness. A number of further influential parameters on the performance of airflow ventilation systems in operating rooms were examined and relevant measures for improvement were identified. It was found that airflow patterns within operating room environments ranged from laminar to transitional to turbulent flows. Regardless of ventilation system used, a combination of all airflow regimes under transient conditions could exist within the operating room area. This showed that applying a general model to map airflow field and contaminant distribution may result in substantial error and should be avoided. It was also shown that the amount of bacteria generated in an operating room could be minimized by reducing the number of personnel present. Infection-prone surgeries should be performed with as few personnel as possible. The initial source strength (amount of colony forming units that a person emits per unit time) of staff members can also be substantially reduced, by using clothing systems with high protective capacity. Results indicated that horizontal laminar airflow could be a good alternative to the frequently used vertical system. The horizontal airflow system is less sensitive to thermal plumes, easy to install and maintain, relatively cost-efficient and does not require modification of existing lighting systems. Above all, horizontal laminar airflow ventilation does not hinder surgeons who need to bend over the surgical site to get a good view of the operative field. The addition of a mobile ultra-clean exponential laminar airflow screen was also investigated as a complement to the main ventilation system in the operating room. It was concluded that this system could reduce the count of airborne particles carrying microorganisms if proper work practices were maintained by the surgical staff. A close collaboration and mutual understanding between ventilation experts and surgical staff would be a key factor in reducing infection rates. In addition, effective and frequent evaluation of bacteria levels for both new and existing ventilation systems would also be important. / Tidigt i mänsklighetens utveckling har kirurgin funnits med i bilden. Hantering av infektioner har genom tiderna varit en oundviklig del av alla kirurgiska ingrepp, och finns kvar ännu idag som en viktig utmaning i operationssalar på sjukhus. För patienter som genomgår kirurgi finns alltid en risk att de efter ingreppet utvecklar någon behandlingsrelaterad komplikation. Allmänt accepterat är att de luftburna bakterier som når operationsområdet huvudsakligen består av stafylokocker frigjorda från hudfloran av operationspersonalen i operationssalen, och att endast en liten del av dessa partiklar behövs för att initiera en allvarlig infektion i det behandlade området. Sårinfektioner innebär inte bara en enorm börda för hälso- och sjukvårdsresurser, utan utgör också en betydande risk för patienten. På sjukhus förvärvad infektion finns bland de främsta dödsorsakerna i kirurgiska patientgrupper.. En bred kunskap och förståelse av spridningsmekanismer och källor till infektionsspridande partiklar kan ge värdefulla möjligheter att kontrollera och minimera postoperativa infektioner. Denna avhandling bidrar till lösningar genom analys av en rad olika ventilationssystem tillsammans med undersökning av andra faktörer som kan påverka infektionsspridningen på sjukhus, främst i operationssalar. Syftet med arbetet är att med hjälp av CFD-teknik (Computational Fluid Dynamics) få bättre förståelse för olika luftspridningsmekanismers betydelse vid ventilation av operationssalar och vårdinrättningar på sjukhus, så att halten av bacteriebärande partiklar i luften kan minskas samtidigt som termisk komfort och luftkvalité förbättras.  Flera luftflödesprinciper för ventilation inklusive omblandade strömning, riktad (laminär) strömning och hybridstrategier har studerats. Simuleringar av luft-, partikel- och spårgasflöden gjordes för alla fallstudier för att undersöka partikelevakuering och luftomsättning i rummet. Flera viktiga parametrar som påverkar detta undersöktes och relevanta förbättringar  föreslås i samarbete med industrin. Av resultaten framgår att mängden genererade bakterier i en operationssal  kan begränsas genom att minska antalet personer i operationsteamet. Infektionsbenägna operationer skall utföras med så lite personal som möjligt. Den initiala källstyrkan (mängden kolonibildande enheter som en person avger per tidsenhet) från operationsteamet kan avsevärt minskas om högskyddande kläder används. Av resultaten framgår också att ett horisontellt (laminärt) luftflöde kan vara ett bra alternativ till det ofta använda vertikala luftflödet. Ett horisontellt luftflöde är mindre känsligt för termisk påverkan från omgivningen, enkelt att installera och underhålla, relativt kostnadseffektivt och kräver vanligen ingen förändring av befintlig belysningsarmatur. Framför allt begränsar inte denna ventilationsprincip kirurgernas rörelsemönster. De kan luta kroppen över operationsområdet utan att hindra luftflödet. En flyttbar flexibel skärm för horisontell spridning av ultraren ventilationsluft i tillägg till ordinarie ventilation undersöktes också. Man fann att denna typ av tilläggsventilation kan minska antalet luftburna partiklar som bär mikroorganismer om operationspersonalen följer en strikt arbetsordning. Bra samarbete och förståelse mellan ventilationsexperter och operationsteamet på sjukhuset är nyckeln till att få ner infektionsfrekvensen. Det är också viktigt med effektiva och frekventa utvarderingar av bakteriehalten i luften, för såväl nya  som befintliga ventilationssystem. / <p>QC 20160129</p>
28

Energeticky efektivní řadový rodinný dům / Energy efficient terraced house

Král, Jakub January 2015 (has links)
The aim of my diploma thesis is a design of a new energy efficient terraced house in the gap site. Building has two dwelling unit of category 4+kitchenette and 6+ kitchenette. Building has a cellar, two floors and an attic. The cellar structures and horizontal structures are made of reinforced concrete. Sand-lime bricks are used for masonry. The building is covered with gabled roof with timber roof truss. In this building there are used rainwater and renewable energy in a form of electrical energy made by photovoltaic panels.
29

Technologie výroby plastového krytu mobilního telefonu / Production technology of mobile phone plastic cover

Heralt, Aleš January 2009 (has links)
The master´s thesis is focused on technology of injection plastics. The specified part is guard cover of mobile phone. The first part of thesis is focused on description of technology with priority on construction of form. The second part of thesis includes calculations of parameters, which are needed for production, along with techno-economic evaluation of selected construction design.
30

Ventilation for reduced indoor spread of Covid 19 and similar diseases : A literature review focusing on hospital environments / Ventilation för minskad inomhusspridning av Covid 19 och liknande sjukdomar : En litteraturstudie med fokus på sjukhusmiljöer

Ourak Pour, Cyrus January 2023 (has links)
Today, a significant portion of individuals’ time is spent indoors, estimated at approximately 90% of their total time. This raises concerns about the transmission of Coronavirus Disease 2019 (COVID-19) instigating Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) and similar viruses and highlights the critical role of ventilation systems in indoor environments, which this study aims to investigate. Narrowing the focus to healthcare facilities, particularly hospitals in Sweden, the study includes the importance of ventilation systems in safeguarding the health safety and well-being of patients, healthcare workers in hospitals. To effectively combat the spread of the SARS-CoV-2 virus, it is crucial to have a thorough understanding of its viral characteristics, with a specific centre on airborne transmission size, virus longevity, and quantum of infection. Furthermore, it is essential to recognize the major impact of ventilation rate, thermodynamic factors such as temperature and humidity, as well as pollutants in effectively mitigating the transmission of SARS-CoV-2 and similar pathogens.  The comprehensive findings of this literature review underscore that, for hospitals in Sweden, a Heat Recovery Ventilation (HRV) system incorporating a plate heat exchanger is the most suitable ventilation system for this specific objective. Moreover, the recommended ventilation strategy is specifically tailored for implementation in wards or isolated rooms, where it is ideal for the incoming air to originate from the patient’s room floor, while the exit point is preferably located near or at the ceiling. In the context of this study, identified effective solutions involve the utilization and combination of high-efficiency filters and ultraviolet (UV) technology installed within ventilation system unit, particularly when an air recirculation system is used. Additionally, the implementation of RM3 (Rheem’s third generation products) UV-C technology for indoor use can be achieved without considerable intervention in ventilation system, depending on the type of ventilation system being utilized. In summary, this study enhances understanding of the complex relationship between ventilation systems, COVID-19 transmission and similar diseases, the optimization of thermodynamic factors, and selection of effective and practical measures. It provides valuable insights for designing effective ventilation strategies across various indoor environments, with a specific attention on healthcare facilities. / Idag spenderas en betydande del av individers tid inomhus, uppskattningsvis cirka 90% av deras totala tid. Detta väcker oro över överföringen av Coronavirussjukdom 2019 (COVID-19), som initierar Svårt Akut Respiratoriskt Syndrom Coronavirus 2 (SARS-CoV-2) och liknande virus och belyser den kritiska rollen som ventilationssystem spelar i inomhusmiljöer, som denna studie syftar till att undersöka. Genom att begränsa fokus till vårdinrättningar, särskilt sjukhus i Sverige, inkluderar studien vikten av ventilationssystem för att säkerställa hälsosäkerheten och välbefinnandet för patienter och vårdpersonal på sjukhus. För att effektivt bekämpa spridningen av SARS-CoV-2-viruset är det viktigt att ha en grundlig förståelse för dess virala egenskaper, med ett specifikt fokus på luftburen överföringsstorlek, viruslivslängd och infektionsmängd. Dessutom är det viktigt att identifiera den stora inverkan av luftomsättningstakt, termodynamiska faktorer som temperatur och fuktighet samt föroreningar för att effektivt minska överföringen av SARS-CoV-2 och liknande patogener. De omfattande resultaten av denna litteraturstudie understryker att värmeåtervinningsventilationssystem (HRV) med plattvärmeväxlare är det mest lämpliga ventilationssystemet för sjukhus i Sverige för detta specifika mål. Dessutom är den rekommenderade ventilationsstrategin speciellt anpassad för implementering på avdelningar eller isolerade rum, där den är idealisk för att inkommande luft ska komma från patientens rumsgolv, medan utgångspunkten företrädesvis är placerad nära eller i taket. I samband med denna studie involverar identifierade effektiva lösningar, användning och kombination av högeffektiva filter och ultraviolett (UV)-teknik installerad i ventilationssystemenhet, särskilt när ett luftcirkulationssystem används. Dessutom kan implementeringen av RM3 (Rheems tredje generationens produkter) UV-C-teknik för inomhusbruk uppnås utan betydande ingrepp i ventilationssystem, beroende på vilken typ av ventilationssystem som används. Sammanfattningsvis ökar denna studieförståelse för det komplexa förhållandet mellan ventilationssystem, COVID-19-överföring och liknande sjukdomar, optimering av termodynamiska faktorer och val av effektiva och praktiska åtgärder. Den ger värdefulla insikter för att utforma effektiva ventilationsstrategier i olika inomhusmiljöer, med särskild uppmärksamhet på vårdinrättningar.

Page generated in 0.1362 seconds