Spelling suggestions: "subject:"vidro."" "subject:"hidro.""
661 |
[pt] COMPORTAMENTO MECÂNICO DE COMPÓSITOS CIMENTÍCIOS REFORÇADOS COM TECIDO DE FIBRAS DE VIDRO E SISAL: ASPECTOS ESTRUTURAIS E DURABILIDADE / [en] MECHANICAL BEHAVIOR OF CEMENT BASED COMPOSITES REINFORCED WITH GLASS AND SISAL FABRIC: STRUCTURAL ASPECTS AND DURABILITYRENNAN LIBERATO RODRIGUES 09 June 2022 (has links)
[pt] A necessidade de estruturas mais leves e esbeltas tem motivado a pesquisa
por materiais alternativos, o que levou, nas últimas décadas, ao concreto têxtil
(TRC) ou argamassa de cimento reforçada com tecido (FRCM). Além da leveza e
finura, vale ressaltar a alta ductilidade deste tipo de compósito. No entanto, ainda
são poucos os estudos sobre o comportamento mecânico desse material,
principalmente quando submetido a situações de alta agressividade ambiental.
Portanto, o objetivo deste estudo é analisar o comportamento mecânico de
compósitos cimentícios reforçados com fibras naturais e tecido de fibra sintética.
Para isso, foram desenvolvidos compósitos em formato de placas e vigas de seção
I fabricados com dois tipos de matrizes, que variavam quanto ao teor de hidróxido
de cálcio, reforçados com diferentes porcentagens de tecido de fibra de vidro álcali
resistente e de fibra de sisal. As amostras foram submetidas a ensaios de tração
direta e flexão a quatro pontos tanto em condições normais quanto após
envelhecimento acelerado em câmara de névoa salina. Concluiu-se que, embora os
elementos reforçados com tecido de fibra de vidro apresentem um desempenho
satisfatório em condições normais de ensaio, quando colocados em ambientes
salinos há uma degradação considerável tanto da fibra quanto da interface entre o
tecido e a matriz, prejudicando a performance do compósito. Observou-se também
que a matriz com baixo teor de hidróxido de cálcio auxiliou na preservação da
capacidade resistente dos tecidos utilizados no estudo, com destaque para o
desempenho compósito reforçado com fibra de vidro ensaiado em condições
normais e o reforçado com fibra de sisal nas duas condições de ensaio propostas. / [en] The need for lighter and slender structures has led civil engineers to look for
alternative materials, which has led, in recent decades, to cementitious composites
reinforced with fabrics. This new type of material is known as textile reinforced
concrete (TRC) or Fabric Reinforced Cement Mortar (FRCM). In addition to the
lightness and slimness, it is worth mentioning the high ductility of the material.
Nevertheless, there are still only a few studies on durability and mechanical
mechanisms when it occurs in situations with high environmental aggressiveness,
such as coastal areas. Therefore, the objective of this study is to analyze the
influence of saline environments on cementitious composites reinforced with
natural sisal and alkali resistant glass fabrics. Two types of matrices were
developed: one with a high calcium hydroxide content, only with Portland cement
and the other with a lower content, due to the partial replacement of Portland cement
by Metacaulim and fly ash. The TRC specimens were placed for accelerated aging
in a salt steam walk-in chamber with a concentration of 3.5 percent NaCl and 70 degree Celsius . After
1000 hours of aging, the specimens were removed from the chamber and subjected
to direct tensile tests. The degradation mechanisms were discussed and a
comparison between the mechanical behavior of the two composite systems were
addressed.
|
662 |
Avaliação clínica randomizada de restaurações de classe II em dentes permanentes de ART e de resina composta / Randomized clinical trial of class II restorations of ART and composite resin in permanent teethSilva, Rafael Menezes 08 December 2017 (has links)
Este estudo avaliou a efetividade de restaurações de classe II por meio da técnica do Tratamento Restaurador Atraumático (ART), com retenções adicionais nas caixas proximais, em dentes permanentes, usando cimento de ionômero de vidro (CIV) de alta viscosidade, em comparação com restaurações convencionais de resina composta. Um exame epidemiológico foi realizado em uma população maior e representativa dos participantes da pesquisa. Cento e trinta e três participantes, de 8 a 28 anos, com boa saúde geral com uma a duas cavidades de classe II em dentes permanentes sem comprometimento pulpar e dor de dente foram incluídos neste estudo, com aprovação pelo Comitê de Ética sob o número: CAAE: 24012913.0.1001.5417. Foram feitas setenta e sete restaurações com cada material restaurador (Equia Fil-GC Corporation e Z350-3M). As restaurações foram avaliadas aos 6, 12 e 24 meses pelos critérios do ART e do Serviço de Saúde Pública dos Estados Unidos (USPHS) modificado. Correlação de Spearman e Regressão Linear Múltipla foram realizados entre as variáveis dor de dente, índice de placa visível (IPV), índice de sangramento gengival (ISG) e os índices CAST (The Caries Assessment Sprectrum and Treatment) e CPOD (contagem de dentes cariados, perdidos e restaurados) dos participantes do levantamento epidemiológico por meio do programa Statistica 7.1. Quanto à efetividade restauradora, os dados foram analisados, utilizando o programa SPSS 23.0, por meio dos testes de Mann-Whitnney, Qui-quadrado, Exato de Fisher, Qui-quadrado com tendência linear e Regressão logística pelo método Enter, quando pertinentes (p<0,050). O Teste de Kaplan-Meier avaliou as taxas de sobrevida das restaurações em relação ao critério do ART e USPHS modificado. O teste de Log-Rank comparou as curvas de sobrevida. Do índice CAST (1,53; 2,17) foi possível extrair o CPOD (0,58; 1,32) o qual apresentou menor especificidade e sensibilidade no registro da cárie. As taxas de sucesso para as restaurações de resina composta foram de 100% (6 meses), 98,7% (12 meses) e 91,5% (24 meses) para ambos os critérios de avaliação e para as restaurações de ART foram as mesmas para 6 meses (98,7%) e 12 meses (95,8%) e para 24 meses foram de 92% quando utilizado o critério do USPHS modificado e 90,3% quando utilizado o critério do ART, não sendo observada diferença estatística (p=0,466). As variáveis sexo, localidade, idade, CPOD, IPV, ISG, dor de dente, oclusão, contato proximal, tamanho da cavidade, anestesia e cooperação do paciente não apresentaram associação estatística com as taxas de sucesso das restaurações (p>0,050). Após 24 meses, as variáveis IPV e ISG não apresentaram odds ratio (OR) estatisticamente significante para as restaurações de ART (p>0,050). As restaurações de ART apresentaram uma sobrevida inferior pelo critério do ART (83,7%) quando comparado à sobrevida pelo critério do USPHS modificado (87,8%), após 24 meses (p=0,051). A sobrevida das restaurações de resina composta foi de 90,7% para ambos os critérios de avaliação. Conclui-se que não há diferença na taxa de sucesso de restaurações de classe II de ART com CIV de alta viscosidade, em dentes permanentes, com sulcos de retenção proximais, em comparação com restaurações de classe II de resina composta, após 24 meses. / This study evaluated the effectiveness of Class II restorations through the Atraumatic Restorative Treatment (ART) technique, with additional retentions in the proximal boxes, in permanent teeth, using high viscosity glass ionomer cement (HVGIC), as compared to restorations of composite resin. An epidemiological examination was conducted in a larger and representative population of the participants of study. One hundred and thirty three participants, aged 8 to 28 years, with good general health with 1 to 2 class II cavities in permanent teeth without pulp involvement and tooth pain were included in this study, with was approved by the Ethics Committee under the number: CAAE: 24012913.0.1001.5417. Seventy-seven restorations were made with each restorative material (Equia Fil-GC Corporation and Z350-3M). Restorations were evaluated at 6, 12, and 24 months by the criteria of ART and the modified United States Public Health Service (USPHS). Spearman Correlation and Multiple Linear Regression were performed between the variables tooth pain, visible plaque index (VPI), gingival bleeding index (GBI) and the CAST (The Caries Assessment Sprectrum and Treatment) and DMFT (Decayed, Missing and Filled teeth) obtained at the epidemiological survey using the Statistica program 7.1. As for restorative effectiveness, data were analyzed using the Mann-Whitnney, Chi-square, Fisher\'s Exact, Chi-square tests with linear trend and Logistic Regression by Enter method, where relevant (p<0.050). The Kaplan-Meier test evaluated the survival rates of the restorations in relation to the ART and modified USPHS criteria. The Log-Rank test compared the survival curves. From the CAST index (1.53; 2.17) it was possible to extract the DMFT (0.58; 1.32) which presented lower specificity and sensitivity in caries detection. The success rates for composite resin restorations were 100% (6 months), 98.7% (12 months) and 91.5% (24 months) for both assessment criteria and for ART restorations were the same for 6 months (98.7%) and 12 months (95.8%) and for 24 months were 92% when using the criteria of modified USPHS and 90.3% when using the criteria of ART, and no statistical difference was observed (p=0.466). The variables gender, locality, age, DMFT, VPI, GBI, toothache, occlusion, proximal contact, cavity size, anesthesia and cooperation of the participant did not present a statistical association with the success rates of the restorations (p>0.050). After 24 months, the VPI and GBI variables did not present a statistically significant odds ratio (OR) for ART restorations (p>0.050). ART restorations presented a lower survival rate by the criteria of ART (83.7%) when compared to the criteria of USPHS modified (87.8%), after 24 months (p=0.051). The survival of composite resin restorations was 90.7% for both evaluation criteria. It was concluded that there is no difference in the success rate of class II restorations of ART with HVGIC, in permanent teeth, with proximal retention grooves, compared to class II resin composite restorations, after 24 months.
|
663 |
Vidros porosos de de alto teor de sílica para armazenamento de rejeitos nucleares. Solidificação, caracterização e lixiviação / High content silica porous glass for nuclear waste storage. Solidification, characterization and leachingSantos, Dayse Iara dos 22 December 1983 (has links)
Apresentamos um estudo de solidificaçaõ e lixiviacão de matrizes de vidros porosos de alto teor de sílica armazenando 20% em peso de solução aquosa simuladora de rejeitos nucleares de alto nível de radioatividade do tipo Savanah River Labratory. A matriz porosa foi preparada após o tratamento térmico de um vidro de 65% SiO2-27%B2O3-8%Na2O, que sofreu separação de fase à 560°C por 20 horas e lixiviado em HCl - 3N à 90°C. O tamanho dos poros (tipicamente de 100 à 250Å de diâmetro) , foi determinado utilizando o método BET. Após sinterização à 1300°C em ar, as amostras foram caracterizadas física e quimicamente através de testes de lixiviação padronizados MCC1, Soxhlet (MCC5) e Estagnante durante cerca de 28 dias. Determinamos a perda de peso total, o pH, as taxas de lixiviação diferencial e as concentrações acumuladas para os seguintes elementos: Si, Na, B, Ca, Mn, Al, Fe e Ni com técnicas de ICP e espectroscopia de chama para o caso do Na. Os resultados são comparados com os obtidos com vidros borosilicatos de referência, fabricados por fusão convencional (SRL 131, PNL 76-68, MCC 76-68, SRL TDS 131, AVM-Ml à M7), vidros fabricados pela técnica sol-gel (TDS 211), vidros de alto teor de sílica (CU PGM), synroc-D, cerâmicas manufaturadas, concreto FUETAP e matrizes metálicas. Os valores obtidos são similares àqueles obtidos com os melhores vidros borosilicato presentemente usados. / We present a study of the sinterization and of the leaching behavior of a high silica porous glass matrix containing 20 weight % of simulated solution of high level liquid nuclear waste of the type Savanah River Laboratory. The porous matrix has been prepared after heat treatment of a 65% SiO2-27%B2O3-8%Na2O glass, phase separate at 560°C for 20 hours and leached in 3N HCl at 90°C. The pore size (typically 100-250Å in diameter) has been determined by the BET method. After sinterization in air at 1300°C, the samples have been physically and chemically characterized during 28 days using the MCC1, Estagnant and Soxhlet (MCC5) standard tests. We have determined thetotal weight loss, the pH, the diferential leaching rate and the cumulative concentrations for the following elements: Si, Na, B, Ca, Mn, Al, Fe and Ni by ICP technique, for Na flames spectroscopy. The results are compared with these obtained with other reference borosilicate glasses made by conventional fusion techniques (SRL 131, PNL 76-68, MCC 76-68, SRL TDS 131, AVM-M1 to M7), glasses made by sol-gel technique (TDS-211), porous glasses matrix (CU PGM), synroc-D, tailored ceramics, FUETAP concrete and metallic matrix. The values obtained are similar to those found for the best borosilicate glass presently used.
|
664 |
Estudo do efeito da radiação ionizante sobre as propriedades da poliamida 6 com reforço de fibra de vidro / Study of the effect of ionizing radiation on properties of polyamide 6 with fibreglass reinforcementPinto, Clovis 25 May 2007 (has links)
É cada vez maior a utilização de polímeros reforçados com fibra de vidro no mercado nacional. Entre eles utiliza-se a poliamida 6 que apresenta ótima resistência à tração, ao impacto e à absorção de umidade comparada à poliamida 6 sem reforço de fibra de vidro, sendo atualmente utilizada na indústria automobilística em peças sob o capô, em especial em carcaças de radiadores. Este trabalho foi realizado com o objetivo de estudar o efeito da radiação ionizante nas propriedades mecânicas (resistência à tração, à flexão e ao impacto Izod) e térmicas (resistência ao fio incandescente e temperatura de fusão) da poliamida 6 com reforço de fibra de vidro, submetida à diferentes doses de radiação (100 a 600 kGy). As amostras foram preparadas e irradiadas em um acelerador JOB 188 com feixe de elétrons de energia de 1,5 MeV em diferentes doses e uma taxa de dose de 22,61 kGy/h. Após a irradiação, as propriedades das amostras da poliamida 6 com reforço de fibra de vidro irradiada foram determinadas e comparadas com as amostras não irradiadas e constatou-se que as propriedades mecânicas de resistência à flexão e à tração aumentaram e a de resistência ao impacto diminuiu. Em relação à propriedade térmica de temperatura de fusão diminuiu de 224,4ºC para 212,5ºC mas a perda de massa diante do aumento constante da temperatura também diminuiu. Em relação à propriedade de resistência ao fio incandescente a poliamida 6 com reforço de fibra de vidro irradiada teve um bom desempenho. As imagens captadas por Microscopia Eletrônica de Varredura mostram que a irradiação provocou uma boa integração entre a fibra de vidro e o polímero o que foi responsável pelo bom desempenho na propriedade de resistência ao fio incandescente. / It is each time more common the use of polymers reinforced with fibreglass in the domestic market. Between them it is used polyamide 6 that it presents good tension resistance, to the impact and the humidity absorption compared with non-reinforced, being also at the present time used in the automobile industry in parts underneath the hood, especially in the radiator frames. The aim of this work is to study the effect of ionizing radiation on properties of polyamide 6 with fibreglass reinforcement, undergone to different radiation doses. Samples were prepared and irradiated on JOB 188 accelerator with an electron beam energy of 1.5 MeV in air with different doses (100 to 600 kGy) and a dose rate of 22.61 kGy/h. Afterward the irradiation, the properties of the samples of irradiated polyamide 6 with fibreglass reinforcement were evaluated and compared with the samples non-irradiated. It evidenced that the mechanical properties flexural resistance and tension resistance increased and the resistance to the impact decreased. Regarding the thermal properties of the temperature of fusing decreased of 224,4ºC for 212,5ºC but the loss of mass ahead of the constant increase of the temperature also decreased. In the property of resistance to the glow wire the polyamide 6 with fibreglass reinforcement had a good performance. The images caught for Scanning Electronic Microscopy show that the irradiation provoked a good integration enters the fibreglass and polymer what was responsible for the good performance in the property of resistance to the glow wire.
|
665 |
Efeito de diferentes modelos de envelhecimento na resistência de união em dentina decídua hígida e cariada / Different degradations models to evaluate bond strength in sound and caries primary dentinCalvo, Ana Flávia Bissoto 04 March 2015 (has links)
A resistência de união (RU) dos materiais deve ser avaliada após a degradação da interface adesiva, tentando simular um processo que ocorre naturalmente ao longo do tempo na cavidade bucal. O presente estudo avaliou a degradação da interface adesiva em diferentes materiais utilizando o modelo de envelhecimento in vitro e in situ em dentina hígida e cariada. Noventa segundos molares decíduos hígidos e sem defeitos de esmalte, foram aleatoriamente divididos em dois grupos de acordo com o substrato a ser testado (hígido e com lesão de cárie induzida). A seguir, cada um dos grupos foi subdividido aleatoriamente de acordo com o material restaurador (n=15): resina composta associada ao sistema adesivo - RC, cimento de ionômero de vidro modificado por resina - CIVMR e cimento de ionômero de vidro de alta viscosidade - CIVAV. A superfície da dentina foi preparada e com o auxílio de cânulas de polietileno, foram confeccionados os espécimes com os materiais restauradores. Partes de um mesmo dente foram submetidas a cada envelhecimento: in vitro (24 horas e 6 meses) - armazenados em água destilada à 37°C; e in situ (uso de dispositivo intraoral palatino por voluntários em uma fase experimental de 7 dias). Os espécimes foram submetidos ao teste de microcisalhamento (MPa) para avaliação da RU, seguido de análise do padrão de fratura em estereomicroscópio (400X). Os dados foram submetidos a análise de variância de medidas repetidas seguida pelo teste de Bonferroni (? = 5%). De forma geral, o armazenamento por seis meses em água degradou o grupo CIVMR em dentina hígida (<0,001) e RC em dentina cariada (p=0,007), para os outros materiais não houve diferença estatística (p=1,00). O modelo in situ influenciou negativamente os valores de RU nos grupos RC e CIVMR (p<0,001) no substrato hígido e na RC (p<0,001), CIVMR (p=0,001) e CIVAV p=0,020) no substrato cariado. Concluí-se que no modelo in vitro, seis meses em água destilada não foram suficientes para degradar a interface de união dos materiais avaliados e o modelo in situ é uma metodologia rápida que pode ser utilizada para avaliar a degradação da interface de união de materiais restauradores em dentina cariada de dentes decíduo. / Materials bond strength (BS) should be evaluated after degradation of the adhesive interface, simulating the intra-oral enviroment. This study assessed the degradation of the bonding interface of differents materials using in vitro and in situ models of aging in sound and caries - affected primary dentin. Ninety sound second primary molars without enamel defects were randomly assigned into two groups (sound and induced carious) according to the substrate to be tested. Then each group was subdivided according to the restorative material (n=15): composite resin associated with the adhesive system - CR, resin-modified glass ionomer cement - RMGIC or high-viscous glass ionomer cement- HVGIC. Dentin surface was prepared and with the aid of polyethylene tubes specimens of each restorative materials were prepared. Parts of a same tooth were subjected to in vitro and in situ models of aging. For in vitro model, the specimens were stored in distilled water at 37°C during 24 hours per 6 months; and for in situ model an intraoral palatal device was confectioned and used by volunteers in an experimental phase for 7 days. Specimens were submitted to microshear test (MPa) for BS evaluation and then stereomicroscopy (400X) analys of failure mode. Data were analyzed by repeated measures ANOVA for followed by Bonferroni test (? = 5%). In general, the storage for six months in distilled water degraded the RMGIC group in sound dentin (<0.001) and RC group in caries-affect dentin substrate (p = 0.007), for the others materials there was no statistical difference (p = 1.00). The in situ model, adversely, influenced the BS in RC and RMGIC groups (p <0.001) in sound substrate, and in RC (p <0.001), RMGIC (p = 0.001) and HVGIC (p = 0.020) in caries-affected dentin. We can concluded that in in vitro model, using six months distilled water, was not sufficient to degrade the bonded interface of the evaluated materials and in situ model is a faster method to evaluate degradation of the adhesion interface of restorative materials in cariesaffected dentin.
|
666 |
VIDRO COMERCIAL COMO DETECTOR E MEDIDOR DE RADIAÇÃO NUM IRRADIADOR DE GRANDE PORTE. / COMMERCIAL PLATE WINDOW GLASS AS DETECTOR AND RADIATION METER AT A TOTE BOX IRRADIATORRodrigues Junior, Ary de Araujo 31 January 2000 (has links)
Amostras de vidro comercial para janelas de fabricação nacional foram testadas como dosímetros de rotina para doses altas em um irradiador de grande porte que utiliza uma fonte de Co-60. Estas amostras foram estudadas em termos da uniformidade do lote, repetibilidade, desvanecimento, resposta à dose absorvida entre 5 e 30 kGy, de processamentos rotineiros. A técnica da absorção óptica foi usada para medir-se as amostras de vidro. Todos os resultados obtidos mostram a viabilidade do uso de amostras de placas de vidro para janelas como um sistema dosimétrico de rotina, assim como indicador de irradiação Sim/Não para doses altas em irradiadores de grande porte que utilizam fontes de Co-60 / Commercial window glass samples were tested as routine high dose dosimeters at a Co-60 tote box irradiator. These samples were studied in terms of their batch uniformity, response repeatibility, fading and absorbed dose response from 5 until 30 kGy in typical irradiation procedures. The optical absorption technique was used to measure the glass samples. All the obtained results show the feasibility of using plate window glass samples as a routine high dose dosimetry system and as a Yes/No irradiation indicator for a Co-60 tote box irradiator.
|
667 |
Desenvolvimento e caracterização de placas poliméricas produzidas a partir da reciclagem do resíduo industrial de poliuretana termofixa / Development and characterization of polymeric plates produced from the recycling of industrial waste thermoset polyurethane.Baldan, Victor José dos Santos 25 February 2015 (has links)
Os compósitos são materiais formados por duas fases de diferentes propriedades químicas e físicas, sendo uma matriz e um reforço, que apresentam alta rigidez, melhores respostas à fadiga sob cargas cíclicas, leveza e resistência mecânica, o que os torna viáveis para substituir materiais nobres e de custo elevado, com diversas aplicações na aeronáutica, nos esportes, na indústria bélica e principalmente na construção civil. Além disso, os compósitos podem ser obtidos a partir da incorporação de resíduos em sua composição, solucionando problemas como o descarte irregular. Com o intuito de contribuir nessa área de conhecimento o presente estudo propôs o desenvolvimento de um compósito em forma de placas poliméricas a partir da incorporação do agregado reciclado de poliuretana termofixa reciclado à resina vegetal de mamona e à mantas de fibra de vidro. Para isso, o trabalho estabeleceu uma metodologia na qual o resíduo industrial de poliuretana termofixa é transformado em agregado reciclado, a partir de processos de corte e moagem, caracterização e classificação segundo as normas NBR 10.004 a 10.007 (ABNT, 2004). Na sequência, com o auxílio de uma prensa térmica, foi possível confeccionar as placas poliméricas e caracterizálas quanto às suas propriedades mecânicas (tração, flexão, punção), físicas (absorção em água, inchamento, densidade e dureza), térmicas (condutividade térmica) e quanto ao seu potencial de durabilidade (resistência ao impacto, à abrasão superficial, ao ataque químico, à exposição ao ultravioleta e às intempéries, resistividade elétrica e flamabilidade). Os resultados obtidos por meio dos ensaios realizados apontaram que os parâmetros ensaiados comportaram-se como materiais semelhantes àqueles utilizados na construção civil, o que possibilita a utilização do material desenvolvido nesta pesquisa em aplicações por este setor. / This study proposes the development of a composite material in the form of polymer slabs. The material is created from the incorporation of recycled thermoset polyurethane to castor oil resin and glass fiber mats. Composite materials are formed by two phases with different chemical and physical properties. One phase is a matrix, and the other a reinforcement. These materials are highly stiff, light, have mechanical strength and present better responses to fatigue under cyclic loads. These properties make them a substitute for noble materials, being eligible for uses in aviation, sports, the arms industry and, specially, civil construction. Furthermore, composites may be obtained by the incorporation of residue, solving problems of waste disposal. In the procedures undertaken, the industrial waste of thermoset polyurethane is transformed into a recycled aggregate, achieved by the cutting, grinding, characterization and classification in compliance to the ABNT standards (NBR 10.004 to10.007). Afterwards, with the use of a thermal press, it was possible to produce the slabs and characterize them according to the following properties: mechanical (tensile strength, and puncture), physical (water absorption, swelling and stiffness), thermal (conductivity) and the potential durability (resistance to impact, abrasion, chemical attack. ultraviolet and weather exposure, electrical resistance, and flammability). The test results indicated that the composite behaves similarly to materials used in civil construction, which enables its use in the area.
|
668 |
Avaliação da microdureza Knoop e do grau de conversão de dois cimentos de ionômero de vidro modificados por resina em função do tipo de polimerização e do tempo / Evaluation of the Knoop microhardness and the degree of conversion of two resin-modified glass ionomer in function of the type of polymerization and the timeMartins, Leandro de Moura 21 May 2007 (has links)
Os ionômeros de vidro vêm sendo utilizados largamente na odontologia com diversas funções. Suas formulações sofreram alterações durante os anos, como a incorporação de componentes resinosos, para a melhoria de suas propriedades físicas e aumento do tempo de trabalho. Com isso, o estudo teve como objetivo avaliar o grau de conversão e a microdureza Knoop dos cimentos de ionômero de vidro modificados por resina (Rely X Luting e Vitremer, ambos da 3M ESPE) de acordo a forma de polimerização (química ou fotopolimerável por lâmpada halógena Ultralux EL ? Gnatus e LED LEC 1000 ? MMOptics) e o tempo de armazenagem. Três espécimes de cada material, autopolimerizável e fotopolimerizável, e tipo de fotopolimerização (por luz halógena e LED) foram confeccionados para cada tempo experimental de 6 horas, 1, 2, 3, 5, 7 ,11 e 14 dias (n=72). Os espécimes foram armazenados em ambiente escuro a 37°C durante esses períodos. Os 72 espécimes foram analisados pela espectroscopia FT-IR para a medição do grau de conversão (GC). Três espécimes de cada material e tipo de polimerização (n=9) foram confeccionados para a medição da microdureza, com um penetrador diamantado piramidal, tipo Knoop, carga estática de 50 gramas por 30 segundos. Os resultados encontrados demonstraram que o material fotopolimerizado com LED apresentou os maiores valores do grau de conversão e da microdureza. O grau de conversão aumentou com o tempo de armazenagem enquanto a microdureza obteve os maiores resultados entre 24-48 horas. Os resultados permitiram concluir que para os cimentos de ionômero de vidro modificados por resina, Vitremer e Rely X Luting, o material fotopolimerizável onde se utilizou o LED apresentou os melhores resultados e que a microdureza Knoop foi ineficaz para predizer o grau de conversão. / Glass ionomer cement have been widely used for many functions. Over the years, some alterations have been made to improve some physico-mechanical properties and to prolong working time. The purpose of this study was to evaluate the relation of the degree of conversion (DC) and Knoop microhardness of resin modified glass ionomer cements (Rely X Luting and Vitremer - 3M ESPE) with polymerization type (chemical curing and light curing reactions, using halogen light or LED) and time of storage. Three specimens of each material, self-cured and light-cured, and light-curing type (halogen light or LED) were prepared for each period of time (n=72). Specimens were stored in dark and dry conditions, at 37oC, during 6 hours, 1, 2, 3, 5, 7, 11 and 14 days. All the specimens were analyzed by FT-IR spectroscopy to measure the DC. Three specimens of each material and polimeryzation type (n=9) were prepared for the microhardness determination, equipped with a Knoop indenter, 50g load for 30 seconds. Results showed that higher values of DC and Knoop microhardness were found on the LED light-cured material. DC values increased with storage time while the Knoop microhardness achieved its higher values between 24-48 hours. Results showed that the LED light-curing unit used to polymerize the resin modified glass ionomer cement Vitremer achieved better values of DC, between light and self-cured materials, and that the Knoop microhardness could not predict the DC.
|
669 |
Avaliação da influência do ultra-som em cimentos de ionômero de vidro na adesão à dentina e nas características dentinárias / Evaluation of ultrasound influence on glass ionomer cement (GIC) regarding its adhesion to dentin and the clinical dentin characteristicsBresciani, Eduardo 23 June 2007 (has links)
Avaliou-se diferentes formas de aplicação do ultra-som (US) sobre a microtração de CIVs (Ketac Molar Aplicap, Ketac Molar Easymix e Fui IX GP) à dentina; e o potencial clínico de restaurações de CIV (Ketac Molar) com US remineralizarem a dentina e seu efeito sobre a flora bacteriana por meio PCR em tempo real, após período de três meses. Na parte laboratorial, foram selecionados 45 terceiros molares extraídos e confeccionadas cavidades para acomodar material, que aleatoriamente recebeu US diretamente (US-D), ou indiretamente (US-I) ou ainda não recebeu (S-US). Os espécimes foram reservados por 1 semana, submetidos ao teste de microtração e os dados analisados por ANOVA 2-critérios. Na parte clínica, 32 pacientes (idade média 13,8) receberam 90 restaurações com CIV, CIV com ultra-som e resina composta, aleatoriamente. A dentina afetada foi avaliada de acordo com a cor, umidade e dureza e uma amostra foi colhida para quantificação de bactérias totais e Lactobacilos. Após três meses, as restaurações foram removidas e nova caracterização clínica e amostragem realizadas. Os dados obtidos foram submetidos aos testes de Friedman e Mann-Witney para os critérios clínicos e ao teste de procedimento de medidas repetidas SAS, para o número de bactérias (p<0,05). Os resultados mostraram que o ultra-som influenciou na adesão dos CIVs, sendo US-D<S-US<US-I. Após três meses de estudo clínico, a dentina apresentouse dura e seca com maior freqüência. A coloração não apresentou mudanças significantes. O número de bactérias totais não foi influenciado pelo tipo de tratamento restaurador. Mais da metade das amostras não mostrou níveis detectáveis de Lactobacilos e nenhuma atividade foi observada. Concluiu-se que o método de aplicação indireta do US deve ser o escolhido. O tipo de tratamento restaurador não influenciou na redução de bactérias residuais, nem na atividade metabólica, embora a dentina apresentasse características clínicas compatíveis com paralisação do processo carioso. / The microtensile bond strength of GICs (Ketac Molar Aplicap, Ketac Molar Easymix and Fuji IX GP), receiving different patterns of ultrasound (US), was evaluated. The clinical potential of GIC (Ketac Molar) restorations with US, in remineralizing dentin and their effects on the microflora were also evaluated. Forty-five extracted third molars were selected for the laboratorial study, and cavities were performed for the GIC filling, which received direct US (D-US), indirect US (I-US) or no US excitation (N-US). After one week, the microtensile test was performed. The obtained data was analyzed using 2-way ANOVA test (P<0.05). Thirty-two patients (mean age of 13.8) were selected for the clinical study and 90 restorations were randomly performed with GIC, GIC plus US or composite resin (CR). The affected dentin was assessed by color, humidity and hardness and a dentin sample was obtained for total bacteria and Lactobacilli quantification, using real time PCR. After 3 months, the restorations were removed and new dentin characterization and sampling performed. Clinical data were analyzed by Friedman and Mann-Whitney tests. Bacterial counts were analyzed by Repeated Measurements Procedure (P<0.05 for all tests). Results showed statistical significant influences of the US on the GIC adhesion to dentin, being D-US<N-US<IUS. After three months of clinical trial, the dentin was scored more frequently as hard and dry. Color was not statistical different in both evaluation periods. The number of total bacteria was not influenced by the type of treatment. Lactobacilli were detected in less than 50% of the samples and presenting no metabolic activity. It was conclude that I-US should be the choice protocol to achieve better adhesion. Although the treated lesions presented clinical characteristics of arrested caries, the type of restoration did not influence the residual bacteria, neither their metabolic activity.
|
670 |
Estudo clínico randomizado de restaurações classe II de ART com e sem retenções proximais em dentes decíduos / Randomized clinical trial of multiple surface ART restorations with and without proximal retentions in primary teethGonçalves, Priscilla Santana Pinto 14 June 2017 (has links)
O tratamento restaurador atraumático constitui-se numa abordagem de cuidados minimamente invasivos que objetivam a prevenção e interrupção da progressão da cárie dentária. Não existe na literatura estudo clínico randomizado em dentes decíduos comparando restaurações de classe II de ART, com e sem retenções adicionais. O objetivo deste trabalho foi avaliar o efeito de sulcos de retenção proximal sobre as taxas de sobrevida das restaurações classe II de ART em dentes decíduos, usando cimento de ionômero de vidro de alta viscosidade e alta resistência flexural. Foram incluídas 183 crianças com idade entre 4 a 7 anos, com boa saúde geral, 1 a 4 cavidades de classe II em molares decíduos sem envolvimento pulpar ou dor de dente. Dessas crianças, 300 dentes foram randomizados e distribuídos em dois grupos, conforme o índice de cárie da criança e o tamanho da cavidade a ser restaurada. Os grupos foram: controle restaurações de ART classe II convencionais (Grupo 1, n=150) e teste restaurações de ART classe II contendo sulcos de retenção proximais (Grupo 2, n=150). Cada um dos grupos seguiu procedimentos clínicos padronizados. No grupo teste as retenções foram realizadas com colher de dentina modificada no ângulo gengivovestibular/ lingual até 0,5 mm da junção amelo-dentinária da margem oclusal. Após 6 e 12 meses 130 restaurações do Grupo 1 e 110 restaurações do Grupo 2 foram examinadas de forma cega utilizando os critérios do ART Frencken adaptado e do USPHS modificado. Para a taxa de sobrevida das restaurações foi utilizado o teste de Kaplan-Meier (p<0,05). Não houve diferença significativa entre os grupos (p=0,70) utilizando os critérios do ART, sendo que as taxas de sobrevida encontradas para ambos os grupos foram superiores a 90%. O mesmo resultado foi observado em todos os critérios (cor, descoloração marginal, recidiva de cárie, forma anatômica, integridade marginal e textura superficial) USPHS (p>0,05). Os principais motivos de falhas das restaurações foram perda total ou parcial da restauração (84%), seguido de inflamação pulpar (16%). Conclui-se que as restaurações classe II de ART com sulcos de retenção proximal apresentaram taxa de sobrevida semelhantes às restaurações sem retenção após 6 e 12 meses. / The atraumatic restorative treatment is an approach of minimally invasive care that aims to prevent and interrupt the progression of dental caries. There is no randomized clinical trial in primary teeth with multiple surface ART restorations, with and without additional retentions. The aim of this study was to evaluate the effect of proximal retention grooves on the survival rates of occlusoproximal ART restorations in primary teeth using high viscosity glass ionomer cement with high flexural strength. A total of 183 children aged 4 to 7 years, with good general health, 1 to 4 occlusoproximal cavities in primary molars without pulp involvement or tooth pain were included. Of these children, three hundred teeth were randomized and alocated into two groups, according to the child\'s caries index and the size of the cavity to be restored. The groups were: control - conventional occlusoproximal ART restorations (Group 1, n=150) and test - occlusoproximal ART restorations containing proximal retention grooves (Group 2, n=150). The procedures of both groups followed standardized steps. In the test group the retentions were performed with a modified dentin spoon at the gingival-vestibular / lingual angle up to 0.5 mm from the amelodentin junction of the occlusal margin. After 6 and 12 months 130 restorations in Group 1 and 110 restorations in Group 2 were examined (blind) using the modified ART Frencken criteria and the modified USPHS criteria. The Kaplan-Meier test was performed for the survival rate of the restorations (p<0.05). There was no significant difference between groups (p=0.70) using the ART criteria, and the survival rates found for both groups were greater than 90%. The same results was observed for all USPHS criteria (color, marginal discoloration, secondary decay, anatomical form, marginal integrity and surface texture) (p>0.05). The main reasons for restorations failure were total or partial loss of restoration (84%), followed by pulpal inflammation (16%). It was concluded that multiple surface ART restorations with proximal retention grooves presented similar survival rates to non-grooves restorations after 6 and 12 months.
|
Page generated in 0.0281 seconds