• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 853
  • 13
  • 12
  • 12
  • 12
  • 12
  • 6
  • 5
  • 4
  • 4
  • 3
  • 2
  • 1
  • Tagged with
  • 879
  • 485
  • 195
  • 181
  • 180
  • 134
  • 129
  • 117
  • 115
  • 105
  • 102
  • 101
  • 99
  • 89
  • 82
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
721

Longevidade de restaurações ART em cavidades ocluso-proximais utilizando três tipos de materiais em molares decíduos. Estudo Clínico Randomizado / Longevity of ART restorations using 3 different materials in cclusoproximal cavities in primary molars - randomized clinical trial

Isabel Cristina Olegario da Costa 04 August 2015 (has links)
O objetivo deste estudo foi avaliar se o novo material nanoparticulado Carbômero de Vidro pode aumentar a taxa de sobrevida de restaurações ART ocluso-proximais quando comparado com um material resinoso modificado por poliácido - Compômero e o Cimento Ionômero de Vidro de alta viscosidade. Um total de 286 crianças de 5 a 7 anos apresentando ao menos uma lesão de cárie ocluso-proximal foram selecionadas no município de Barueri, SP. Os pacientes foram distribuídos aleatoriamente em três grupos: CIV de alta viscosidade (CIV - Fuji IX Extra - GC Corp), Compômero (COM - Dyract Extra - Dentsply) e Carbômero de Vidro (CAR - Glass Carbomer - GCP Dental). Todos os tratamentos foram feitos seguindo os preceitos do ART e as recomendações dos fabricantes. As restaurações foram avaliadas após 2, 6 e 12 meses por um examinador treinado. Para verificação da sobrevida das restaurações foi utilizada a análise de sobrevida de Kaplan-Meier e teste log-rank. Para avaliar a associação entre o desfecho e as variáveis características do paciente foi aplicado o teste de Regressão de Cox. O nível de significância para os testes foi considerado 5%. Após 12 meses de acompanhamento, a sobrevida geral das restaurações foi de 52,8%. A taxa de sobrevida do CIV, COM e CAR foram de 62,6%, 61,3% e 36,3%, respectivamente. A análise estatística mostrou diferença significante entre os materiais, onde o CAR apresentou pior desempenho (HR=1,84; IC 1,19-2,85; p=0,006) e nenhuma diferença foi encontrada entre os materiais CIV e COM. Além disso, foram encontradas diferenças estatísticas para a variável volume da cavidade, onde cavidades menores apresentaram maiores chances de insucesso (p<0,03). Podemos concluir que o novo material Carbômero de Vidro não é adequado para o uso em restaurações ART proximais de molares decíduos em comparação com CIV de alta viscosidade e o Compômero. / The aim of this study was to evaluate if the new nanoparticulate material, the glass carbomer can increase the survival rate of occlusal-proximal-ART restorations compared with compomer - a polyacid resin modified material and a high viscosity glass ionomer cement (GIC). A total of 286 children aged 5 to 7 years presenting at least one occlusal-proximal carious lesion were selected in the city of Barueri, SP. Patients were randomized into three groups: high viscosity GIC (GIC - Fuji IX Extra - GC Corp), Compomer (COM - Dyract Extra - Dentsply) and Glass Carbomer (CAR - Glass Carbomer - GCP Dental). All treatments were made following the precepts of ART and manufacturers\' recommendations. The restorations were evaluated after 2, 6 and 12 months by a trained examiner. To verify the survival of the restorations was used Kaplan-Meier survival analysis and log-rank test. To evaluate the association between the outcome and patient variables was applied Cox regression test. The significance level for the tests was 5%. After 12 months of follow-up, overall survival rate of the restorations was 52.8%. The GIC, COM and CAR survival rate were 62.6%, 61.3% and 36.3%, respectively. Statistical analysis showed significant differences between the materials, where the CAR had a worse performance (HR = 1.84, CI 1.19 to 2.85; p = 0.006) and no difference was found between the CIV and COM materials. Moreover, statistical differences were found for the variable volume of the cavity, where smaller cavities had higher chances of failure (p <0.03). We conclude that the new glass carbomer material is not suitable for use in ART occlusal-proximal restorations in primary molars compared to high viscosity GIC and the compomer.
722

[en] LOCAL BUCKLING BEHAVIOR OF PULTRUDED GLASS-FIBER REINFORCED POLYMER (PGFRP) I-SECTION COLUMNS / [pt] FLAMBAGEM LOCAL DE COLUNAS PULTRUDADAS EM POLÍMERO REFORÇADO COM FIBRA DE VIDRO (PGFRP) COM SEÇÃO I

GISELE GOES CINTRA 11 February 2019 (has links)
[pt] Este trabalho tem como objetivo investigar o desempenho de colunas com seção I em polímeros reforçados com fibra de vidro (pGFRP) submetidas a cargas de compressão concêntricas de curta duração. Uma revisão bibliográfica acerca das teorias existentes é apresentada, incluindo os conceitos básicos de instabilidade, teoria de flambagem global e local, modos de falha de colunas perfeitas, bem como o comportamento de colunas reais. Um programa experimental foi conduzido, incluindo a caracterização dos materiais. Vinte e nova colunas – com três diferentes seções I e diferentes tipos de resina, propriedades mecânicas, bem como comprimentos – foram testadas. Do ponto de vista global, as colunas foram biengastadas. As placas constituintes, por sua vez, foram testadas com três diferentes condições de contorno: biengastadas (CC), biapoiadas (SS) e simplesmente em contato com as chapas de base da máquina de compressão (CB). Foi observado que a condição de contorno CB – a mais adotada em estudos anteriores -, se aproxima mais de um engaste do que de uma condição simplesmente apoiada. A distribuição não linear de deformações elásticas ao longo da seção também foi investigada. Finalmente, recomendações para um ensaio de flambagem local apropriado foram propostas. / [en] This work aims to investigate the performance of pultruded glass fiber reinforced polymer (pGFRP) I-section columns subject to short term concentric compression. A review of existing theories is presented, including the instability concepts, global and local buckling theories, perfect columns failure modes and the behavior of real columns. An experimental program including material characterization was conducted. Twenty-nine stubs – with three different I-sections geometries, having distinct flange width-to-section depth ratios (bf/d = 0.5; 0.75 and 1.0), mechanical properties, overall lengths and matrices – were tested. In a global point of view, the columns were fixed at both ends. The constituent plates, on the other hand, were tested with different end-conditions: clamped (CC), simply supported (SS) and simply in contact with base plates of the universal machine (CB). The third analyzed boundary condition, which is the most adopted in previous studies, was concluded to be closer to a clamped end-condition. The non-linear elastic strains distribution throughout the cross-section was also investigated. Finally, guideline recommendations for successful local buckling tests were proposed.
723

Efeito do desafio erosivo nas propriedades e na estabilidade de união de materiais restauradores ao esmalte e dentina de dentes decíduos / Effect of erosive challenge on the properties and bond stability of restorative materials to enamel and dentin of primary teeth

Tedesco, Tamara Kerber 05 December 2014 (has links)
Este estudo avaliou o efeito do desafio erosivo nas propriedades e na estabilidade de união de materiais restauradores ao esmalte e dentina decídua. Duzentos e quarenta molares decíduos foram alocados em 24 grupos, de acordo com substrato - esmalte ou dentina, condição prévia do substrato - hígido ou erodido, material restaurador - resina composta associada ao sistema adesivo - RC, cimento de ionômero de vidro de alta viscosidade - CIVAV, ou modificado por resina - CIVMR, e tratamento após procedimento adesivo - controle (imersão em solução salina/7dias) ou desafio erosivo (imersão em bebida a base de cola por 5 min/3x ao dia/7 dias). Os dentes dos grupos esmalte e dentina erodidos foram submetidos ao desafio erosivo previamente aos procedimentos restauradores. Cânulas de polietileno foram posicionadas sobre superfícies planas dos substratos pré-tratados, para então serem preenchidas por um dos materiais avaliados. Após armazenamento por 24h a 37°C, os espécimes foram submetidos a um dos tratamentos propostos. Metade dos espécimes foi submetida imediatamente ao teste de microcisalhamento e a outra metade após 12 meses de armazenamento em água a 37ºC. Posteriormente, a análise do padrão de fratura foi realizada em estereomicroscópio (400X). Para a análise de resistência à flexão (RF) e rugosidade superficial (RS), trinta corpos de prova foram confeccionados (10x2x1mm). Após armazenamento por 24h, a leitura inicial de RS de dez corpos de prova selecionados aleatoriamente foi obtida. Os corpos de prova foram então imersos em um dos tratamentos propostos - desafio erosivo ou solução salina, para então ser realizada a segunda leitura. Decorrido esta análise, os corpos de prova foram submetidos ao teste de RF (1mm/min). Os valores de resistência de união (RU), bem como de RS e RF obtidos foram submetidos a Análise de Variância e Teste de Tukey (?=5%). Análise de Weibull foi também conduzida considerando os valores de RF. De forma geral, os substratos hígidos resultaram em maiores valores de RU do que os erodidos, com exceção do CIVAV que obteve desempenho similar em ambos substratos. Além disso, o tempo influenciou negativamente a RU somente para os grupos de RC quando da avaliação em dentina. Os demais grupos não apresentaram redução nos valores após 12 meses de armazenamento em água. RC apresentou melhor desempenho adesivo do que os demais materiais avaliados, tanto em 24 horas quanto após 12 meses. O desafio erosivo após o procedimento adesivo apenas influenciou negativamente a RU quando os materiais foram avaliados em dentina erodida. Em relação a RS, menores valores foram obtidos para RC. Além disso, o desafio erosivo influenciou os valores de leitura final, resultando em maior RS para todos os materiais restauradores. Já para a RF, RC demonstrou maiores valores de RF, módulo de Weibull e resistência característica do que os demais materiais. Ademais, o desafio erosivo não afetou estes parâmetros. Em conclusão, o desafio erosivo influencia negativamente a RS e RU a dentina erodida. Os substratos previamente erodidos resultam em pior desempenho da RC e CIVMR. Além disso, o armazenamento em água afeta a estabilidade de união a dentina de RC. / This study evaluated the effect of erosive challenge on the properties and bond stability of restorative materials to primary enamel and dentin. Two hundred and forty primary molars were assigned into 24 groups, in according to the substrate - enamel or dentin, the precondition of substrate - sound or eroded, the restorative material - resin composite associated to adhesive system - RC, high-viscous glass ionomer cement- HVGIC or resin-modified glass ionomer cement - RMGIC, e the treatment after restorative procedure - control (immersion in saline solution/7 days) or erosive challenge (immersion in cola-based drink for 5 min/3x per day/7 days). Teeth from the eroded dentin and enamel groups were subjected to erosive challenge prior to bonding procedures. Polyethylene tubes were placed on flat surfaces of the pretreated substrates, and then were filled up with one of evaluated materials. After storage for 24h at 37ºC, the specimens were submitted to one of the proposed treatments. Half of the specimens were immediately submitted to the microshear bond strength test, and the other half after 12 months of water storage at 37ºC. Subsequently, the failures pattern evaluation was performed in stereomicroscopy (400X). For the assessment of flexural strength (FS) and superficial roughness (SR), thirty specimens were built up (10x2x1mm). After storage for 24h, the first reading of SR from ten specimens randomly selected was obtained. Specimens were immersed in one of proposed treatments - erosive challenge or saline solution, to then be performed the second reading. After this assessment, specimens were submitted to FS (1mm/min). The bond strength (BS) values, as well as SR and FS obtained were submitted to analysis of variance and Tukey\'s test (?=5%). Weibull analysis was also performed considering the FS values. Generally, the sound substrates resulted in higher BS values than eroded ones, with exception of the HVGIC that obtained similar performance in both substrates. Furthermore, the storage time negatively influenced the BS values for the RC groups on dentin assessment. The other groups did not show reduction in BS values after 12 months of water storage. RC showed better bonding performance than others evaluated materials, in both at 24 hours as for 12 months at 37ºC. Erosive challenge after bonding procedure only negatively influenced the BS values when the materials were evaluated in eroded dentin. In relation to SR, lower values were obtained to RC. Moreover, erosive challenge affected the second reading, resulting in increased SR for all restorative materials. For FS, RC showed higher values of FS, Weibull modulus and characteristic strength than other materials. Furthermore, immersion in erosive challenge did not affect these parameters. In conclusion, erosive challenge negatively influences SR and BS to eroded dentin. Previously eroded substrate result in the worst performance of RC and RMGIC. Moreover, the water storage affects the bonding stability of RC to dentin.
724

Uso de um lodo de cromo proveniente da indústria de curtume na fabricação de vidros sodo-cálcicos. / Use of tannery sludge containing chromium compounds in soda-lime glass fabrication.

Peralta, Marvin Marco Chambi 12 August 2014 (has links)
A indústria de produção de couro gera uma grande quantidade de resíduos com características poluentes e de elevada periculosidade, entre os quais se destacam os resíduos curtidos (aparas, serragem e pó de couro curtido) e os lodos provenientes das estações de tratamento de efluentes (lodos de cromo, lodos primários e lodos secundários). Estes resíduos possuem uma considerável quantidade de compostos de Cr(III) na sua composição, os quais, sob condições oxidantes, podem transformar-se em Cr(VI), que é altamente tóxico para animais, plantas e seres humanos. No entanto, estes resíduos constituem uma potencial fonte alternativa de cromo (tradicional pigmento industrial) que poderia ser aproveitada pela indústria de vidros e de esmaltes. No presente trabalho foi realizado o estudo das propriedades físicas e químicas de um lodo de cromo proveniente do distrito industrial do município de Franca/SP, com o intuito de avaliar a viabilidade da utilização das cinzas da incineração deste resíduo como uma potencial fonte alternativa de cromo na fabricação de vidros sodo-cálcicos coloridos para embalagens. Fluorescência de Raios X (FRX), Difração de Raios X (DRX), análises termodiferencial (DTA) e termogravimétrica (TG/DTG), análise elementar, análise granulométrica, determinação de poder calorífico pelo método da bomba calorimétrica e Microscopia Eletrônica de Varredura (MEV) foram usados para determinar as características físicas e químicas do lodo de cromo. A incineração do resíduo foi realizada numa mufla elétrica a 800 C, utilizando um cadinho de alumina. A determinação da concentração de íons Cr(VI) presentes no lodo e nas cinzas foi realizada através do método colorimétrico utilizando difenilcarbazida. Vidros sodo-cálcicos contendo as cinzas da incineração do lodo de cromo foram preparados por meio da fusão das matérias-primas industriais (areia, barrilha e calcário) em cadinhos de alumina a 1500 C por 1h, sob condições similares às utilizadas no processo industrial de produção de vidros comerciais de coloração verde (composição, adição de ferro e condições redutoras). Para fins de comparação, foram preparadas também amostras de vidros contendo cromita (tradicional fonte industrial de cromo utilizada pela indústria de vidros) sob condições semelhantes. As amostras de vidros foram caracterizadas em termos de composição química por FRX, MEV, DRX, coordenadas colorimétricas (sistema CIEL*a*b*) e absorção óptica. Os resultados de FRX mostraram que as cinzas apresentam um teor de cromo de aproximadamente 47% em massa de Cr2O3, valor não muito distante do teor de cromo observado na composição da cromita (cerca de 43% em massa de Cr2O3). Os vidros preparados utilizando cromita e as cinzas da incineração de lodo de cromo apresentaram bandas de absorção óptica semelhantes no intervalo analisado (200-3300 nm), sem a presença aparente da banda de absorção óptica entorno de 370 nm, característica do íon Cr6+. Estes resultados sugerem que sob condições adequadas de incineração do lodo, bem como formulação e fusão do vidro, é possível utilizar-se as cinzas obtidas como fonte alternativa de cromo para a fabricação de vidros coloridos do sistema soda-cal-sílica. / Leather production industry generates large quantities of solid wastes with pollutant characteristics and hazardous conditions, such as tanned wastes (Chrome shaving, chrome splits and buffing dust) and sludges from wastewater treatment process (Tannery sludge, primary and secondary sludge). These wastes containing Cr(III), which, under oxidizing conditions, can turn into Cr(VI), an extremely toxic and cancerigenous form of the element. However, these wastes are a potential source of chromium (traditional industrial pigment) which could be used by the glass and ceramic enamels industries. In the present work was studied the physical and chemical properties of a tannery sludge from the industrial district of the city of Franca, São Paulo State, Brazil, in order to evaluate the feasibility of using the ashes from incineration of this waste as a potential alternative source of chromium for the manufacturing of soda-lime glasses. X-Ray Fluorescence (XRF), Xray Diffraction (XRD), Differential Thermal Analysis (DTA), Thermogravimetric Analysis (TG/DTG), elemental analysis, granulometric analysis, determination of calorific value by the bomb calorimeter method and Scanning Electron Microscopy (SEM) were used to determine the physical and chemical characteristics of tannery sludge. The tannery sludge incineration was performed using an alumina crucible in a electric oven at 800 C. Colorimetric method using diphenylcarbazide were conducted to determinate the Cr(VI) concentration in the waste and the ashes from incineration. Soda-lime glass containing the ashes from incineration of tannery sludge was prepared by melting of industrial raw materials (sand, soda ash and limestone), in alumina crucibles at 1500 C for 1 hour, under similar conditions to those used in the industrial production process of commercial green container glasses (composition, addition of iron and reducing conditions). For comparison purposes, glasses containing chromite (traditional industrial source of chromium used by the glass industry) were also prepared under similar conditions. The glass samples were characterized in terms of chemical composition by XRF, MEV, DRX, color (CIEL*a*b* system) and optical absorption. The FRX results revealed that the ashes are composed by about 47 wt% Cr2O3. This amount is not so far from the chromium content observed in the composition of chromite (about 43 wt% Cr2O3). The glasses containing chromite and the ashes from the incineration of the tannery sludge exhibited approximately similar optical absorption bands in the analyzed range (200-3300 nm), without the presence of optical absorption band around 370 nm, characteristic of Cr 6+. These results suggests that under appropriate incineration conditions of the sludge, as well as formulation and melting of glass, is possible use the chromium-rich ashes from incineration of tannery sludge as an alternative source of chromium for the manufacturing of colored glasses of the soda-lime-silica system.
725

Longevidade de restaurações ART em cavidades ocluso-proximais utilizando três tipos de materiais em molares decíduos. Estudo Clínico Randomizado / Longevity of ART restorations using 3 different materials in cclusoproximal cavities in primary molars - randomized clinical trial

Costa, Isabel Cristina Olegario da 04 August 2015 (has links)
O objetivo deste estudo foi avaliar se o novo material nanoparticulado Carbômero de Vidro pode aumentar a taxa de sobrevida de restaurações ART ocluso-proximais quando comparado com um material resinoso modificado por poliácido - Compômero e o Cimento Ionômero de Vidro de alta viscosidade. Um total de 286 crianças de 5 a 7 anos apresentando ao menos uma lesão de cárie ocluso-proximal foram selecionadas no município de Barueri, SP. Os pacientes foram distribuídos aleatoriamente em três grupos: CIV de alta viscosidade (CIV - Fuji IX Extra - GC Corp), Compômero (COM - Dyract Extra - Dentsply) e Carbômero de Vidro (CAR - Glass Carbomer - GCP Dental). Todos os tratamentos foram feitos seguindo os preceitos do ART e as recomendações dos fabricantes. As restaurações foram avaliadas após 2, 6 e 12 meses por um examinador treinado. Para verificação da sobrevida das restaurações foi utilizada a análise de sobrevida de Kaplan-Meier e teste log-rank. Para avaliar a associação entre o desfecho e as variáveis características do paciente foi aplicado o teste de Regressão de Cox. O nível de significância para os testes foi considerado 5%. Após 12 meses de acompanhamento, a sobrevida geral das restaurações foi de 52,8%. A taxa de sobrevida do CIV, COM e CAR foram de 62,6%, 61,3% e 36,3%, respectivamente. A análise estatística mostrou diferença significante entre os materiais, onde o CAR apresentou pior desempenho (HR=1,84; IC 1,19-2,85; p=0,006) e nenhuma diferença foi encontrada entre os materiais CIV e COM. Além disso, foram encontradas diferenças estatísticas para a variável volume da cavidade, onde cavidades menores apresentaram maiores chances de insucesso (p<0,03). Podemos concluir que o novo material Carbômero de Vidro não é adequado para o uso em restaurações ART proximais de molares decíduos em comparação com CIV de alta viscosidade e o Compômero. / The aim of this study was to evaluate if the new nanoparticulate material, the glass carbomer can increase the survival rate of occlusal-proximal-ART restorations compared with compomer - a polyacid resin modified material and a high viscosity glass ionomer cement (GIC). A total of 286 children aged 5 to 7 years presenting at least one occlusal-proximal carious lesion were selected in the city of Barueri, SP. Patients were randomized into three groups: high viscosity GIC (GIC - Fuji IX Extra - GC Corp), Compomer (COM - Dyract Extra - Dentsply) and Glass Carbomer (CAR - Glass Carbomer - GCP Dental). All treatments were made following the precepts of ART and manufacturers\' recommendations. The restorations were evaluated after 2, 6 and 12 months by a trained examiner. To verify the survival of the restorations was used Kaplan-Meier survival analysis and log-rank test. To evaluate the association between the outcome and patient variables was applied Cox regression test. The significance level for the tests was 5%. After 12 months of follow-up, overall survival rate of the restorations was 52.8%. The GIC, COM and CAR survival rate were 62.6%, 61.3% and 36.3%, respectively. Statistical analysis showed significant differences between the materials, where the CAR had a worse performance (HR = 1.84, CI 1.19 to 2.85; p = 0.006) and no difference was found between the CIV and COM materials. Moreover, statistical differences were found for the variable volume of the cavity, where smaller cavities had higher chances of failure (p <0.03). We conclude that the new glass carbomer material is not suitable for use in ART occlusal-proximal restorations in primary molars compared to high viscosity GIC and the compomer.
726

Avaliação de dois cimentos de ionômero de vidro comparados a um selante resinoso, utilizados para selamento de fossas e fisuras aplicados em esmalte bovino hígido, sob condições de severo desafio cariogênico: estudo in situ / Evaluation of two glass ionomer cements compared to a resin sealant, employed for pit and fissure sealing on intact bovine enamel, under severe cariogenic challenge - in situ study

Biella, Vivian de Agostino 02 March 2007 (has links)
Este estudo in situ, desenvolvido em uma fase de 14 dias, teve como objetivo avaliar o efeito de dois cimentos de ionômero de vidro (CIV) comparados a um selante resinoso, utilizados para selamento de fossas e fissuras aplicados em esmalte bovino hígido, com acúmulo de biofilme dentário, por meio da análise do conteúdo de flúor do biofilme dentário e da microdureza em secção longitudinal. Foram utilizados 88 blocos de esmalte (4mm x 4mm) de incisivos bovinos, selecionados por seu valor de microdureza inicial. Os blocos formaram uma fissura artificial em forma de \"V\" a qual foi selada, para compor os seguintes grupos: GI-CIVav (Ketac? Molar Easymix); GII-CIV modificado por resina (Vitremer?); GIII-selante resinoso sem flúor (Helioseal® Clear) ou GIV-controle, sem selamento. As fissuras artificiais foram fixadas em um dispositivo intrabucal palatino (DIP), em duas fileiras distintas que foram cobertas por uma tela plástica para favorecer o acúmulo de biofilme dentário. Onze voluntários utilizaram o DIP 24 h/dia; gotejaram 8x/dia, uma solução de sacarose a 20% e, uma solução de dentifrício fluoretado (3ml de água deionizada : 1g de dentifrício fluoretado) sobre todas as fissuras 3x/dia. Após o período experimental, coletou-se o biofilme acumulado para a avaliação do conteúdo de flúor. As fissuras foram seccionadas ao meio para a avaliação da microdureza em secção longitudinal a partir da superfície do esmalte, em 4 profundidades (10, 30, 50, 70 µm). O limite esmalte/material da região oclusal era a posição zero (borda do material) e, a partir deste, realizadas seqüências de impressões a 50, 150 e 500 µm interna e externamente à borda do material. Os dados obtidos foram analisados estatisticamente (a= 5%). O teste de Friedman revelou que a concentração de flúor no biofilme não foi estatisticamente significante entre os grupos, (p<0,07), com uma tendência de melhores resultados para o CIVav. Quanto ao conteúdo mineral, a ANOVA e o teste de Tukey detectaram significância (p<0,05) para todos os grupos individualmente, na camada mais superficial do esmalte (10 µm). Nesta profundidade, não houve diferença entre os grupos. Essas comparações foram válidas para a maioria das distâncias analisadas. / This in situ study, developed in a 14-day period, aimed to evaluate the effect of two glass ionomer cements (GIC) compared to a resin sealant, employed for pit and fissure sealing on intact bovine enamel, with accumulation of dental biofilm, by analysis of the fluoride content on the dental biofilm and longitudinal microhardness. Eighty-eight enamel blocks (4mm x 4mm) of bovine incisors were employed, selected according to their initial microhardness value. The blocks formed a V-shaped artificial fissure that was sealed, constituting the following groups: GI - high-viscosity conventional GIC (Ketac? Molar Easymix); GII - resin-modified GIC (Vitremer?); GIII - resin sealant without fluoride (Helioseal? Clear); and GIV - control, without sealing. The artificial fissures were fixated on a palatal plate (PP), in two distinct rows, which were covered with a plastic screen to favor the accumulation of dental biofilm. Eleven volunteers employed the PP for 24h/day, dripped a 20% sucrose solution 8 times a day, and used a fluoridated dentifrice solution (3ml of deionized water : 1g of fluoridated dentifrice) on all fissures 3 times a day. After the study period, the accumulated biofilm was collected for evaluation of the fluoride content. The fissures were sectioned through the middle for evaluation of longitudinal microhardness from the enamel surface, at 4 depths (10, 30, 50, 70 µm). The enamel/material limit at the occlusal region was the zero position (material margin); from this point, indents were sequentially performed at 50, 150 and 500 µm internally and externally to the material margin. Data were statistically analyzed (a = 5%). The Friedman test revealed that the fluoride concentration in the biofilm was not statistically significantly different among groups (p<0.07), yet there was a tendency of better outcomes for the high-viscosity conventional GIC. With regard to the mineral content, the ANOVA and Tukey test revealed significance (p<0.05) for all groups individually, at the most superficial enamel layer (10 µm). At this depth, there was no difference among groups. These comparisons were valid for most distances analyzed..
727

Estudo da viabilidade de fabricação de um tubo para construção de uma prótese de membro inferior em composito híbrido epóxi carbono-vidro / Viability of hybrid epoxi carbon-glass composite pipe manufacture for use in lower limb prosthesis

Lebrão, Guilherme Wolf 01 March 2007 (has links)
Neste trabalho propôs-se a construção de um tubo de material compósito híbrido, com fibra de vidro e fibra de carbono, para utilização como prolongador de prótese de membro inferior a serem fabricadas pela AACD - Associação de Assistência à Criança Deficiente. O objetivo é avaliar as solicitações da prótese para otimizar custo e reduzir a massa. Fez-se inicialmente um levantamento das propriedades dos materiais comerciais utilizados para a fabricação do prolongador para referenciar o desenvolvimento do componente da prótese. Utilizou-se modelagem por elementos finitos para otimizar o componente em função dos esforços biomecânicos a que a prótese é submetida. Nesta modelagem, estudaram-se várias disposições, quantidade e material das camadas de forma a atender às solicitações e minimizar os custos. O levantamento bibliográfico permitiu encontrar uma rota de menor custo para a fabricação de compósito que utiliza um processo de transferência de resina auxiliado a vácuo e pré-formados de vidro e carbono. Como referência, foi fabricado um componente pelo processo de bobinagem filamentar que produz materiais compósitos de qualidade reconhecida. O processo de moldagem por transferência de resina assistido à vácuo, apesar de ter alguns insumos importados, pela sua simplicidade pode ser realizado na própria AACD e se mostrou capaz de obter componentes com custo que viabiliza sua produção sem grandes investimentos em equipamentos. Apesar da redução de algumas das propriedades em relação à peça de referência, o tubo apresentou vantagens na redução de massa e na absorção de impacto. / In this work it was considered a construction of a pipe of hybrid composite material, with carbon and glass fibre, for use as prosthesis extension of inferior member to be manufactured for the Associação de Assistência à Criança Deficiente AACD. The objective is to evaluate the requests of prosthesis to optimize cost and to reduce weight. A survey of the properties of the commercial materials commonly used for the manufacture extension became initially a reference to the development of the final component. A finite element modeling was used to optimize the component in the biomechanics function related to the efforts which the prosthesis is submitted. In this modeling some disposals and numbers of layers, amount and material have been studied to take care of the requests and to minimize the cost. A bibliographical survey allowed finding a shipper route for the manufacture of composite that uses a process of vacuum assisted resin transfer molding and preforms of glass with carbon. As reference, a component was produced using filament winding process to compare the quality of the obtained composite pipe. The process, although to have some imported feed-stock, can be proper carried out by AACD and if it showed capable to produce components with cost that makes possible its production internally. Despite the reduction of some of the properties in relation to the reference part, the component presented advantages such as weight reduction and the impact absorption.
728

Estudo da radiopacidade de materiais odontológicos indicados como base e forramento de restaurações. Análise através da radiografia digital / Study of the radiopacity of dental materials used as base and liner of restorations. Analysis by digital radiographic

Lachowski, Karina Monteleone 03 June 2011 (has links)
A radiopacidade é um importante pré-requisito para materiais utilizados como base e forramento de restaurações, pois possibilita que o profissional identifique a presença do material e permita sua diferenciação com a estrutura dental adjacente. O objetivo desse estudo foi avaliar a radiopacidade de materiais indicados como base e forramento e comparar com a radiopacidade do esmalte, dentina e escala de alumínio. Para isso, foram analisadas 16 marcas comerciais de cimento de ionômero de vidro, 8 marcas de resina composta flow e 4 marcas de cimento de hidróxido de cálcio. Foram confeccionados três conjuntos de três corpos de prova de 4 mm de diâmetro, com espessuras de 1, 2 e 3 mm para cada cimento de ionômero de vidro e resina composta flow e de 1 mm para cada cimento de hidróxido de cálcio. Foram feitas secções transversais de coroas de três terceiros molares humanos para obtenção de espécimes de esmalte e dentina com espessura de 1, 2 e 3 mm. Como controle, uma escala de alumínio padrão com nove degraus de espessura foi utilizada. As tomadas radiográficas foram feitas com o sistema digital RVG 5000 Kodak (Kodak Company, França) e tempo de exposição de 0.32 segundos. As imagens obtidas foram trabalhadas no programa Image Tool® para obtenção dos valores médios de cinza. A análise estatística ANOVA, seguida pelo teste de Tukey (p0.05) detectou diferenças consideráveis entre os materiais da mesma categoria e entre as espessuras. Algumas marcas comerciais apresentaram radiopacidade inadequada segundo as normas ISO 4049 e 9917 (Ionomaster, Maxxion, Bioglass R, Bioglass F, Vidrion R e Vidrion F), apresentando radiopacidade inferior à da dentina, insuficiente para um correto diagnóstico. Todas as resinas compostas flow e cimentos de hidróxido de cálcio estudados apresentam radiopacidade superior a da dentina. As marcas comerciais Vitro Fil, Magic Glass, Vitrebond, Riva SC, Riva LC, Fill Magic, Opallis, Surefil Tetric N, Tetric, Hydro C, Hydcal e Liner apresentaram radiopacidade igual ou superior a do esmalte, em todas as espessuras. De um modo geral, o aumento de espessura dos materiais estudados aumenta significativamente sua radiopacidade. Conclui-se que existem materiais indicados como base e forramento de restaurações com radiopacidade inadequada para serem detectados radiograficamente. / Radiopacity is an important pre-requisite for base and liner materials, once it allows the professional to identify the presence of the material and makes its differentiation from the adjacent tooth structure possible. The aim of this study was to evaluate the radiopacity of liner and base materials and compare to the radiopacity of enamel, dentin and aluminum stepwedge. For this, 16 glass ionomer cements, 8 flowable resin composites and 4 calcium hydroxide cements were analysed. It was prepared three sets of three test specimens with 4 mm in diameter and thicknesses of 1, 2 and 3 mm for each glass ionomer cement and flowable composite and 1 mm for each calcium hydroxide cement. Cross sections were made from crowns of three third molars to obtain specimens of enamel and dentin with thickness of 1, 2 and 3 mm. As a control, a standard aluminum stepwedge with nine steps was used. Radiographs were taken with digital Kodak RVG 5000 (Kodak Company, France) and exposure time of 0.32 seconds. The images were analysed through the program Image Tool ® to obtain the mean grey values. Statistical test ANOVA followed by Tukey test (p 0.05) detected significant differences between the materials of the same category and between the thicknesses. The commercial brands Ionomaster, Maxxion, Bioglass R, Bioglass F, Vidrion R and Vidrion F, presented radiopacity lower than the radiopacity of dentin, insufficient for a correct diagnostic. All flowable resin composites and calcium hydroxide cements studied showed radiopacity superior than dentin. Vitro Fil, Magic Glass, Vitrebond, Riva SC, Riva LC, Fill Magic, Opallis, Surefil, Tetric N, Tetric, Hydro C, Hydcal and Liner showed radiopacity equal to or greater than the enamel for all thicknesses. In general, the increased thickness of the materials studied increases its radiopacity significantly. It was concluded that some materials indicated as base and liner for restorations have and inadequate radiopacity to be detected radiographically.
729

A influência do material restaurador na sobrevida de restaurações ART em molares decíduos baseado em Ensaios Clínicos Randomizados / The influence of restorative material on survival of ART restorations in primary molars based on Randomized Clinical Trials

Costa, Isabel Cristina Olegario da 21 September 2018 (has links)
Este trabalho envolve os resultados de três diferentes ensaios clínicos randomizados: (1) restaurações ART em cavidades oclusais utilizando Fuji IX (GC), Vitro Molar (Nova DFL) e Maxxion R (FGM); (2) restaurações ART oclusoproximais utilizando Ketac Molar (3M ESPE) e Vitro Molar (Nova DFL) e (3) Restaurações ART em cavidades oclusais e ocluso-proximais utilizando Glass Carbomer (GCP), Dyract (Dentsply) e Equia Fill (GC). O objetivo desta tese foi avaliar se a escolha do material tem influência na sobrevida de restaurações ART em molares decíduos. Um total de 835 crianças de 4 a 8 anos de idade (estudo 1: n=150; estudo 2: n=117; estudo 3: n=568) com lesões de cárie em dentina sem sinais de envolvimento pulpar foram selecionadas e tratadas em escolas públicas do município de Barueri-SP. Os pacientes foram randomizados de acordo com o grupo de material restaurador de cada estudo. Todos os tratamentos foram feitos seguindo os preceitos do ART e as recomendações dos fabricantes. As restaurações foram avaliadas por examinador independente, treinado e calibrado (estudo 1 e 2: até 24 meses e estudo 3: até 36 meses de acompanhamento). Para verificação da sobrevida das restaurações foi utilizada a análise de sobrevida de Kaplan-Meier e teste log-rank. Para avaliar a associação entre o desfecho e as variáveis características do paciente foi aplicado o teste de Regressão de Cox (IC=95%). No estudo 1, a sobrevida de restaurações oclusais em molares dentes decíduos é maior ao utilizar o material Fuji IX (72,7%) quando comparado aos materiais VitroMolar (46,5%) e Maxxion R (39,6%). Não houve diferenças entre os materiais Maxxion R e Vitro Molar. No estudo 2, monstrou-se que sobrevida de restaurações oclusoproximais é maior ao utilizar o material Ketac Molar (48,6%) quando comparado ao VitroMolar (25,4%). Já no estudo 3, o material Glass Carbomer (CAR) apresenta menor sobrevida quando comparado ao cimento de ionômero de vidro de alta viscosidade (CIV)- Equia Fill e ao compômero (COM)- Dyract, tanto em cavidades oclusais (CIV=83%; COM=78%; CAR=62,5%) quanto em ocluso-proximais oclusais (CIV=56,19%; COM=56,15%; CAR=36,33%). Nenhuma diferença é observada entre o compômero e o cimento de ionômero de vidro de alta viscosidade. Outros fatores como sexo, arcada, lado, experiência de 38 cárie, operador e volume da cavidade não influenciaram a sobrevida das restaurações (p>0,05). Dessa forma, conclui-se que a sobrevida das restaurações ART em molares decíduos é influenciada pela escolha do material restaurador. Os materiais que apresentaram melhores resultados nestes ensaios clínicos randomizados foram: Fuji IX (GC Corp), Ketac Molar (3M ESPE), Equia Fill (GC Corp) e Dyract (Dentsply). Registro no ClinicalTrials.gov: Capítulo 1: NCT02377297; Capítulo 2: NCT02267720; Capítulo 3: NCT02217098. / This thesis compiles the results of three different randomized clinical trials: (1) ART occlusal restorations using Fuji IX (GC), Vitro Molar (Nova DFL) and Maxxion R (FGM); (2) ART occlusal restorations using Ketac Molar (3M ESPE) and Vitro Molar (Nova DFL) and (3) ART restorations in occlusal and occlusoproximal cavities using Glass Carbomer (GCP), Dyract (Dentsply) and Equia Fill (GC). The aim of this thesis was to evaluate if the restorative material can influence the survival of ART restorations in primary dentition. A total of 835 children 4 to 8 years of age (study 1: n = 150, study 2: n = 117, study 3: n = 568) with dentin carious lesions without pulp involvement were selected and treated in public schools of the city of Barueri-SP. Patients were randomized according to the restorative material group of each study. All treatments were done following the ART precepts and the manufacturers\' recommendations. Restorations were evaluated by single trained and calibrated examiner (study 1 and 2: up to 24 months and study 3: up to 36 months follow-up). Kaplan-Meier survival analysis and log-rank test were used to verify the survival of the restorations. The Cox Regression test was used to evaluate the association between the outcome and the independent variables (CI=95%). In study 1, the survival of occlusal restorations in primary molars was higher using Fuji IX (72.7%) when compared to VitroMolar (46.5%) and Maxxion R (39.6%). There were no differences between Maxxion R and VitroMolar. In study 2, it was shown that survival of occlusoproximais restorations is higher when using Ketac Molar (48.6%) when compared to VitroMolar (25.4%). In the study 3, Glass Carbomer (CAR) material presented lower survival when compared to the high viscosity glass ionomer (GIC) - Equia Fill and to compomer (COM) - Dyract, both in occlusal cavities (GIC = 83%, COM = 78%, CAR = 62.5%) and occlusal-proximal ones (GIC = 56.19%, COM = 56.15%, CAR = 36.33%). No difference is observed between the compomer and the high viscosity glass ionomer cement. Other factors such as sex, jaw, side, caries experience, operator and volume of the cavity did not influence the survival of the restorations (p> 0.05). Thus, it is concluded that survival of ART restorations in primary molars is influenced by the restorative material. The materials that showed 40 the best results in these randomized controlled trials were Fuji IX (GC Corp), Ketac Molar (3M ESPE), Equia Fill (GC Corp) and Dyract (Dentsply). ClinicalTrials.gov Registration: Chapter 1: NCT02377297; Chapter 2: NCT02267720; Chapter 3: NCT02217098.
730

Modelos matemáticos para planejamento da produção em indústrias de embalagens de vidro / Mathematical models for production planning in the glass container industry problems

Amorim, Flaviana Moreira de Souza 19 June 2019 (has links)
Esta tese de doutorado apresenta modelos matemáticos de problemas de dimensionamento de lotes para planejamento da produção na indústria de embalagens de vidro, que são essenciais em qualquer cadeia de produção, pois são responsáveis por proteger e conservar os produtos (alimentos e bebidas). Na literatura científica são raros os trabalhos que abordam estudos sobre problemas combinados de dimensionamento de lotes e planejamentos da produção em indústrias de embalagens de vidro. Com a finalidade de preencher esta lacuna, a presente tese tem por objetivo propor modelos inéditos e métodos de resolução aplicáveis em problemas nas indústrias de embalagens de vidro. Dessa forma, propõem-se dois modelos baseados em problemas reais para a construção ou reforma de forno(s), denominados de Problema de Instalação de um Novo Forno e Problema de Instalação de Múltiplos Fornos, que verificam a capacidade de fusão e as configurações das máquinas instaladas. Outros dois modelos são desenvolvidos a partir de estudos de casos referentes ao planejamento e ao controle da produção de ampolas de garrafas térmicas. No primeiro estudo, considera-se o máximo da produção líquida e no segundo, minimiza-se os set-up, sendo que em ambos os casos a realidade de uma fábrica é refletida. A complexidade desses modelos contribui para o uso de métodos heurísticos e meta-heurísticos como técnicas para resolução dos mesmos. No entanto, considera-se também a avaliação da associação desses métodos ao uso de programação matemática. Para isso, modelos matemáticos são propostos dentro do contexto das indústrias consideradas. Desta forma, uma heurística de Filtro Guloso e as meta-heurísticas como o Algoritmo Genético Simples, o Algoritmo Genético Multi-Populacional e o Algoritmo Genético Modificado são utilizados na determinação das variáveis inteiras presentes nos modelos matemáticos. Além disso, utiliza-se um método exato, por meio da ferramenta CPLEX, para determinar as variáveis contínuas. Os estudos são conduzidos a partir de dados fornecidos por indústrias localizadas no Brasil e em Portugal. Portanto, os resultados colaboram com o estado da arte nessa área de pesquisa e com o processo de fabricação industrial de embalagens de vidro. / This doctoral dissertation presents mathematical models of lot-sizing problems for production planning in the glass containers industry, which are essential in any production chain, as they are responsible for protecting and conserving products (food and beverages). In the scientific literature, studies addressing combined problems of batch sizing and production planning in glass containers industries are rare. In order to fill this gap, this thesis aims to propose novel models and resolution methods applicable to problems in the glass containers industry. Thus, we propose two models based on real problems for the construction or remodelling of the furnace (s), called New Furnace Installation Problem and Multiple Furnace Installation Problem, which verify fusibility and configurations of installed machines. We developed two other models from case studies regarding the planning and control of the production of thermos vials. In the first study, we consider the maximum net production; in the second, we minimize the set-up. Both cases reflect the reality of a factory. The complexity of these models contributes to the use of heuristic and metaheuristic methods as techniques for their resolution. However, we also consider the evaluation of the association of these methods with the use of mathematical programming. For this, we propose mathematical models within the context of the considered industries. Thus, a Greedy Filter heuristic and metaheuristics such as the Simple Genetic Algorithm, the Multi-Population Genetic Algorithm and the Modified Genetic Algorithm are used to determine the integer variables present in mathematical models. Besides, we use an exact method from CPLEX tool to determine continuous variables. The studies are conducted from data provided by industries located in Brazil and Portugal. Therefore, the results collaborate with state of the art in this research area and with the industrial glass containers manufacturing process.

Page generated in 0.0402 seconds