• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

referensvärden för arteria subclavia och arteria brachialis undersökt med ultraljud och doppler

Al-Najjar, Huda January 2020 (has links)
Kärlsjukdomar är en av de vanligaste sjukdomarna som förekommer bland befolkningen. Två artärer som huvudsakligen försörjer kroppens armar med blod heter arteria subclavia och arteria brachialis. I dagsläget finns det inga referensvärden för arteria subclavia och arteria brachialis. Detta faktum gör det svårare att undersöka dessa kärl och besvara frågeställningar som rör dem. Ultraljud är en lämplig metod för att följa upp sjukdomstillstånd i dessa kärl, eftersom ultraljud både är non-invasivt, kostnadseffektivt och ger inte patienten några obehag eller utsätter dem för strålning. Syftet med studien var att samla in ett referensmaterial för olika värden i arteria subclavia och arteria brachialis som kan användas i kliniken. För att utarbeta referensvärden av diameter, volymflöde och blodflödeshastighet utfördes en ultraljudsundersökning på 25 friska deltagare, 8 män och 17 kvinnor. Referensvärden för vänster respektive höger diameter av arteria brachialis låg mellan 3,1-3,5 mm och 3,2-3,6 mm. Volymflödet i vänster respektive höger arteria brachialis låg mellan 0,029-0,042 L/min och 0,035-0,049 L/min. Blodflödeshastigheten i vänster respektive höger arteria brachialis låg mellan 0,818-0,968 m/s och 0,881-0,946 m/s. Diametern av vänster respektive höger arteria subclavia låg mellan 4,7-5,4 mm och 4,8-5,5 mm. Volymflödet i vänster respektive höger arteria subclavia låg mellan 0,087-0,124 L/min och 0,096-0,119 L/min. Blodflödeshastigheten i vänster respektive höger arteria subclavia låg mellan 0,948-1,106 m/s och 0,909-1,118 m/s. Parametrar som hade signifikant samband med ålder i denna studie var blodflödeshastighet och volymflöde i höger arteria brachialis och diametern i vänster och höger arteria subclavia. Utifrån denna studie kan inga tydliga slutsatser dras gällande vilka referensvärden som bör användas i kliniken. Detta på grund av låga antalet deltagare och liten åldersspridning. / Vascular disease is one of the most common diseases that occurs among the population. Two of the arteries, which mainly supply the arms with blood, is called subclavian artery and brachial artery. Today, there are no reference values for the subclavian artery and the brachial artery. This makes it more difficult to examine these vessels and answer questions that concern them. Ultrasound is a suitable method in order to observe conditions in these vessels, since the ultrasound is both non-invasive and cost-effective and the method do not give the patient any discomfort or expose them to radiation. The purpose of this study was to obtain reference values for subclavian artery and brachial artery plexus, which can be used in different vessel examinations at the department. In order to develop the reference values of the diameter, the volume flow rate and the blood flow velocity of subclavian artery and brachial artery, an ultrasound scan was carried out in 25 healthy participants, 8 males and 17 females. Reference values for the left and right diameters of the brachial artery were between 3.1-3.5 mm and 3.2-3.6 mm. The volume flow in the left and right brachial artery was between 0.029-0.042 L/min and 0.035-0.049 L/min. The blood flow velocity in the left and right brachial artery was between 0.818-0.968 m/s and 0.881-0.946 m/s. The diameter in the left and right subclavian was between 4.7-5.4 mm and 4.8-5.5 mm. The volume flow in the left and right subclavian, was between 0.087-0.124 L/min and 0.096-0.119 L/min. The blood flow velocity in the left and right subclavian was between 0.948-1.106 m/s and 0.909-1.118 m/s. Parameters that had significant correlation with age in this study were blood flow velocity and volume flow in the right brachial artery and the diameter of the left and right subclavian artery. Based on this study, no clear conclusions can be drawn as to which reference values should be used in the clinical practice. This is due to a low number of participants and low age distribution.
2

Luftvärmeväxlare med låg ljudnivå : Även i symbios med solfångare / Heat exchanger with low sound emission : Even in symbiosis with a solar collector

Listén, Lars-Åke, Wallin, Harald January 2007 (has links)
<p>Rapporten handlar om ett examensarbete omfattande 20 p som är utfört för Thermia AB i Arvika. Uppdragsgivaren ville få fram förslag på möjliga åtgärder som kan minska ljudnivån från en luftvärmeväxlare. För bra helhetsbild av projektet, läs även kapitel: 6.</p><p>Värmeväxlaren ingår som en komponent i ett värmepumpssystem, Thermia Aer 5, som använder uteluften som värmekälla. Huvudmålet med projektet blev alltså att undersöka och utvärdera ljudbildningen från värmeväxlaren samt att komma fram till olika förslag på möjliga åtgärder som har potential att sänka ljudnivån. Värmeväxlarens förmåga att uppta energi fick ej heller försämras.</p><p>I projektets slutskede tillverkades det också en enkel prototyp på ett av designförslagen där den störande ljudnivån blev lägre. Läs mer om detta längre ner.</p><p>Ett delmål som vi själva formulerade, var också att undersöka olika möjligheter att öka värmepumpssystemets totala kapacitet för energiupptagning genom att kombinera systemet med någon form av solfångare. Kombinationen solfångare och luftvärmeväxlare innebär också en lägre ljudnivå eftersom fläkten i värmeväxlaren mer sällan behöver gå på full effekt. I viss mån har även estetiska aspekter på formgivningen beaktats.</p><p>Nedan presenteras fyra olika förslag på idéer för att öka luftvärmeväxlarens prestanda:</p><p>Av det första förslaget tillverkades en prototyp där luftvärmeväxlarens utblås är riktat uppåt, istället för som nu åt sidan, vilket minskar risken att omgivningen nås av högfrekvent ljud. Högfrekvent ljud sprids nämligen inte så mycket i sidled.</p><p>Batteridelen på värmeväxlaren har fått en större area, vilket möjliggör ett minskat volymflöde av luft, utan att den tappar i effekt, jämfört med nuvarande värmeväxlare.</p><p>Dessa två åtgärder reducerar det avgivna ljudet med ca10 dB.</p><p>En större batteriarea är även positivt ur energisynpunkt då värmefaktorn (COP) ökar på grund av ett minskat antal nödvändiga avfrostningar.</p><p>Förslag nummer två inbegriper en solfångarlösning som, tack vare avsaknaden av direktförångning, även går att direktkoppla till köldbäraren (brinen) eller direkt mot värmepumpens ackumulatortank.</p><p>Solfångaren täcker hela effektbehovet på sommaren och ger ett tillskott resten av året.</p><p>Det tredje förslaget är en s.k. väggplacerad luftsolfångare som förvärmer insugsluften till värmeväxlaren. Den uppenbara fördelen med detta alternativ är den synnerligen enkla konstruktionen vilket gör att kostnaden kan hållas nere, se bild 4.4.4-2.</p><p>Det fjärde förslaget, är att låta hela husets tak fungera som en solfångare som bilderna 6-1 visar. Inströmmande luft till värmeväxlaren förvärms av de soluppvärmda takpannorna som kan vara av tegel, betong eller ännu hellre av glas. Dessutom tillvaratas förlustvärme från hustak och ventilation. Detta förslag ger ett mycket gott energiutbyte.</p><p>Ytterligare ett intressant sätt att sänka ljudbildningen är att driva fram luften genom värmeväxlaren, helt eller delvis, med hjälp av en hög elektrisk spänning, se kapitel: 6.6.</p> / <p>This report is a candidate degree and the assignment is done in the interest of Thermia AB in Arvika, Sweden. The company wanted proposals of preventive measures aiming to reduce sound emission from a heat exchanger. For a good general impression of the project, see chapter 6. The heat exchanger forms a part of a component in a heat pump system, called Thermia Aer 5, which uses air from outside as a heat source.</p><p>The main target of the project was to examine and evaluate sound emission from the heat exchanger and to get different proposals on possible preventive measures in order to lower sound emission. It was not allowed to reduce the heat exchangers ability to collect energy.</p><p>In the end of the project a simple prototype was built which took advantage of some of the design proposals. The sound emission from the prototype was reduced.</p><p>Another target, formulated by ourselves, was to examine different possibilities to increase the capacity of the heat pump system by combining it with solar collectors. The heat pump system combined with solar collectors also produces reduced sound emission.</p><p>Even some aesthetic aspects have been taken into consideration.</p><p>Below, four different proposals of ideas are introduced that can increase the performance of the heat exchanger:</p><p>The first solution was to direct the air exhaust upwards instead of the tangential exhaust on the present heat exchanger. This makes it more improbable that a high frequency sound wave should reach the surrounding area. Sound with high frequency doesn’t spread so much in a sideways direction. An increase of the battery area makes it possible to lower the air volume flow, because of the increased potential for energy output. These two measures reduced the sound level with a proximal amount of about 10 dB. In addition, an increased exchange battery area increases the heat factor (COP) due to the frost distribution on the battery.</p><p>Solution number two include a solar panel that, due to the lack of direct vaporization in the heat pump system, is possible to serial connect direct on the brine or indirectly to the water accumulation tank. The solar panel gives hot water in the summer and an additional energy output the rest of the year.</p><p>The third solution is a wall mounted air solar panel which gives the air a higher input temperature to the air heat exchanger. This is a very simple and cost effective solution.</p><p>The fourth solution is to let the whole roof of the house act as a solar collector as the pictures 6-1 describes. The sun heats the roofing tile which, in turn, heats streaming air that reaches the heat exchanger. The tile can been made of tiling, concrete - or preferably - transparent glass. Furthermore heat loss from the roof and ventilation is prevented.</p><p>Another interesting solution that reduces sound emission is to force air through the exchanger with a high electric voltage field. Further information chapter: 6.6.</p>
3

Luftvärmeväxlare med låg ljudnivå : Även i symbios med solfångare / Heat exchanger with low sound emission : Even in symbiosis with a solar collector

Listén, Lars-Åke, Wallin, Harald January 2007 (has links)
Rapporten handlar om ett examensarbete omfattande 20 p som är utfört för Thermia AB i Arvika. Uppdragsgivaren ville få fram förslag på möjliga åtgärder som kan minska ljudnivån från en luftvärmeväxlare. För bra helhetsbild av projektet, läs även kapitel: 6. Värmeväxlaren ingår som en komponent i ett värmepumpssystem, Thermia Aer 5, som använder uteluften som värmekälla. Huvudmålet med projektet blev alltså att undersöka och utvärdera ljudbildningen från värmeväxlaren samt att komma fram till olika förslag på möjliga åtgärder som har potential att sänka ljudnivån. Värmeväxlarens förmåga att uppta energi fick ej heller försämras. I projektets slutskede tillverkades det också en enkel prototyp på ett av designförslagen där den störande ljudnivån blev lägre. Läs mer om detta längre ner. Ett delmål som vi själva formulerade, var också att undersöka olika möjligheter att öka värmepumpssystemets totala kapacitet för energiupptagning genom att kombinera systemet med någon form av solfångare. Kombinationen solfångare och luftvärmeväxlare innebär också en lägre ljudnivå eftersom fläkten i värmeväxlaren mer sällan behöver gå på full effekt. I viss mån har även estetiska aspekter på formgivningen beaktats. Nedan presenteras fyra olika förslag på idéer för att öka luftvärmeväxlarens prestanda: Av det första förslaget tillverkades en prototyp där luftvärmeväxlarens utblås är riktat uppåt, istället för som nu åt sidan, vilket minskar risken att omgivningen nås av högfrekvent ljud. Högfrekvent ljud sprids nämligen inte så mycket i sidled. Batteridelen på värmeväxlaren har fått en större area, vilket möjliggör ett minskat volymflöde av luft, utan att den tappar i effekt, jämfört med nuvarande värmeväxlare. Dessa två åtgärder reducerar det avgivna ljudet med ca10 dB. En större batteriarea är även positivt ur energisynpunkt då värmefaktorn (COP) ökar på grund av ett minskat antal nödvändiga avfrostningar. Förslag nummer två inbegriper en solfångarlösning som, tack vare avsaknaden av direktförångning, även går att direktkoppla till köldbäraren (brinen) eller direkt mot värmepumpens ackumulatortank. Solfångaren täcker hela effektbehovet på sommaren och ger ett tillskott resten av året. Det tredje förslaget är en s.k. väggplacerad luftsolfångare som förvärmer insugsluften till värmeväxlaren. Den uppenbara fördelen med detta alternativ är den synnerligen enkla konstruktionen vilket gör att kostnaden kan hållas nere, se bild 4.4.4-2. Det fjärde förslaget, är att låta hela husets tak fungera som en solfångare som bilderna 6-1 visar. Inströmmande luft till värmeväxlaren förvärms av de soluppvärmda takpannorna som kan vara av tegel, betong eller ännu hellre av glas. Dessutom tillvaratas förlustvärme från hustak och ventilation. Detta förslag ger ett mycket gott energiutbyte. Ytterligare ett intressant sätt att sänka ljudbildningen är att driva fram luften genom värmeväxlaren, helt eller delvis, med hjälp av en hög elektrisk spänning, se kapitel: 6.6. / This report is a candidate degree and the assignment is done in the interest of Thermia AB in Arvika, Sweden. The company wanted proposals of preventive measures aiming to reduce sound emission from a heat exchanger. For a good general impression of the project, see chapter 6. The heat exchanger forms a part of a component in a heat pump system, called Thermia Aer 5, which uses air from outside as a heat source. The main target of the project was to examine and evaluate sound emission from the heat exchanger and to get different proposals on possible preventive measures in order to lower sound emission. It was not allowed to reduce the heat exchangers ability to collect energy. In the end of the project a simple prototype was built which took advantage of some of the design proposals. The sound emission from the prototype was reduced. Another target, formulated by ourselves, was to examine different possibilities to increase the capacity of the heat pump system by combining it with solar collectors. The heat pump system combined with solar collectors also produces reduced sound emission. Even some aesthetic aspects have been taken into consideration. Below, four different proposals of ideas are introduced that can increase the performance of the heat exchanger: The first solution was to direct the air exhaust upwards instead of the tangential exhaust on the present heat exchanger. This makes it more improbable that a high frequency sound wave should reach the surrounding area. Sound with high frequency doesn’t spread so much in a sideways direction. An increase of the battery area makes it possible to lower the air volume flow, because of the increased potential for energy output. These two measures reduced the sound level with a proximal amount of about 10 dB. In addition, an increased exchange battery area increases the heat factor (COP) due to the frost distribution on the battery. Solution number two include a solar panel that, due to the lack of direct vaporization in the heat pump system, is possible to serial connect direct on the brine or indirectly to the water accumulation tank. The solar panel gives hot water in the summer and an additional energy output the rest of the year. The third solution is a wall mounted air solar panel which gives the air a higher input temperature to the air heat exchanger. This is a very simple and cost effective solution. The fourth solution is to let the whole roof of the house act as a solar collector as the pictures 6-1 describes. The sun heats the roofing tile which, in turn, heats streaming air that reaches the heat exchanger. The tile can been made of tiling, concrete - or preferably - transparent glass. Furthermore heat loss from the roof and ventilation is prevented. Another interesting solution that reduces sound emission is to force air through the exchanger with a high electric voltage field. Further information chapter: 6.6.
4

Radar Based Solutions for Crushing andScreening Applications / Tillämpning av radarbaserade system inom gruvindustrin

Ehrlin, Emma January 2022 (has links)
This project was carried out for a Company in the mining and construction business, and focused on the development of a radar based material monitoring solution for conveyor belts. A minor prestudy showed that there are possible customer values related to material monitoring solutions for equipment relevant for the Company, and that such solutions using radar possibly can fulfil the application requirements. The main focus of the project was chosen based on this prestudy. The methods used were mainly experiments with the developed prototype, and a study of literature. The prototype was developed with an aim to measure mass flow and to monitor the material surface for deviances. Millimeter-wave pulsed coherent radar sensors were used, and data processing approaches included Kalman filtering. Results showed that mass flow can be calculated using the tested senors and data processing models, as the calculated mass flow was well in line with a belt scale reference, but that additional data is needed to prove consistency in the results. Results also showed that trends in the material surface can be observed in the radar data, indicating the possibilities to detect deviances. From a technical perspective, results and the possibilities for further development and improvement show that radar based solutions can be used for applications relevant for the Company. / Detta examensarbete genomfördes för ett företag inomgruv- och anläggningsbranschen och handlade om utvecklingen av en radarbaserad prototyp för mätningar av materialet på transportband. En mindre förstudie visade på möjliga kundvärden relaterade till sådana mätningar, samt att radar har potentialen att uppfylla kravspecifikationen för flera applikationer. Huvudfokuset för projektet valdes sedan utifrån denna förstudie. Metoderna som användes var främst experiment med den utvecklade prototypen samt litteraturstudier. Prototypen utvecklades med syfte att mäta massflöde samt att upptäcka avikelser i materialets yta. Radarsensorer med en frekvens på 60GHz användes, och för databehandling användes bland annat ett Kalman-filter. Resultaten visade att massflöde kan beräknas med de testade sensorerna och databehandlingsmodellerna, eftersom det beräknade massflödet låg i linje med referensdata från en bandvåg. Ytterligare data behövs emellertid för att visa hur resultaten påverkas av förändrade omständigheter, såsom storleken på fragmenten som mäts. Studien visade också att mönster i materialytan kan observeras i radardatan, vilket indikerar att det också är möjligt upptäcka avvikelser. Ur ett teknisktperspektiv visar resultaten och möjligheterna till vidareutveckling tillsammans att radarbaserade lösningar kan användas för applikationer relevanta för företaget.

Page generated in 0.0315 seconds