• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 24
  • 16
  • 14
  • 7
  • 7
  • 4
  • 4
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 114
  • 18
  • 18
  • 16
  • 15
  • 13
  • 12
  • 11
  • 11
  • 10
  • 10
  • 10
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Dados de garantia e análise qualitativa de especialistas como base para estudo de confiabilidade no setor de máquinas agrícolas

Bonetti, Lauro Viçosa January 2009 (has links)
Ultimamente as empresas têm buscado entender e aprimorar a confiabilidade de seus produtos para atender a crescente exigência dos clientes quanto à qualidade. Desta forma, as empresas também visam aumentar seus lucros, reduzir gastos com garantia e transmitir uma boa imagem de sua marca. Como contribuição a este tema, a presente dissertação apresenta um estudo de confiabilidade de um produto, baseado em recursos de baixo custo disponíveis nas empresas, os quais consistem os dados de garantia e a análise qualitativa dos especialistas. O objetivo do estudo representa desenvolver um método para modelar a vida útil de sistemas e componentes, e apresentar esta através da aplicação em um estudo de caso de certo equipamento agrícola. Para fundamentar a elaboração do método, o trabalho apresenta uma revisão bibliográfica sobre confiabilidade e análise qualitativa. O estudo explora o comportamento dos dados de garantia da empresa, a metodologia Delphi para obtenção da opinião dos especialistas, e a multiplicação de duas funções Weibull para consolidação dos resultados. Como principais resultados são apresentados: a curva de confiabilidade do sistema; o comportamento de falha dos componentes; e avaliação sobre o funcionamento do método. / Lately, companies have been urged to understand and improve their product reliability in order to meet the increasing costumer demand for quality. In doing so, the companies also aims at increasing its profits, reducing warranty claims’, and transmitting a good image of its brand. As a contribution to this subject, this dissertation presents a product reliability study based on low cost resources available in the companies, such as warranty data and experts’ qualitative analysis. The aim of this study is to develop a method to model the life cycle of systems and components, and demonstrate this method through a case study of agricultural equipment. This study presents a bibliographical review on reliability and qualitative analysis as well as other relevant subjects to support the method development. The study explores the company warranty data behavior, the Delphi methodology to obtain the experts’ opinions, and the multiplication of two Weibull distributions for the outcome consolidation. The main results presented are: the system reliability curve; the components failure analysis; and a method evaluation.
52

A alienacao fiduciaria em garantia : um contrato tipico socialmente atipico

Lourenco, Jose Augusto de Carvalho January 2010 (has links)
University of Macau / Faculty of Law
53

Predicting and reducing warranty costs by considering customer expectation and product performance

Sharma, Naresh Kumar, January 2008 (has links) (PDF)
Thesis (Ph. D.)--Missouri University of Science and Technology, 2008. / Vita. The entire thesis text is included in file. Title from title screen of thesis/dissertation PDF file (viewed March 2, 2009) Includes bibliographical references (p. 216-220).
54

Dados de garantia e análise qualitativa de especialistas como base para estudo de confiabilidade no setor de máquinas agrícolas

Bonetti, Lauro Viçosa January 2009 (has links)
Ultimamente as empresas têm buscado entender e aprimorar a confiabilidade de seus produtos para atender a crescente exigência dos clientes quanto à qualidade. Desta forma, as empresas também visam aumentar seus lucros, reduzir gastos com garantia e transmitir uma boa imagem de sua marca. Como contribuição a este tema, a presente dissertação apresenta um estudo de confiabilidade de um produto, baseado em recursos de baixo custo disponíveis nas empresas, os quais consistem os dados de garantia e a análise qualitativa dos especialistas. O objetivo do estudo representa desenvolver um método para modelar a vida útil de sistemas e componentes, e apresentar esta através da aplicação em um estudo de caso de certo equipamento agrícola. Para fundamentar a elaboração do método, o trabalho apresenta uma revisão bibliográfica sobre confiabilidade e análise qualitativa. O estudo explora o comportamento dos dados de garantia da empresa, a metodologia Delphi para obtenção da opinião dos especialistas, e a multiplicação de duas funções Weibull para consolidação dos resultados. Como principais resultados são apresentados: a curva de confiabilidade do sistema; o comportamento de falha dos componentes; e avaliação sobre o funcionamento do método. / Lately, companies have been urged to understand and improve their product reliability in order to meet the increasing costumer demand for quality. In doing so, the companies also aims at increasing its profits, reducing warranty claims’, and transmitting a good image of its brand. As a contribution to this subject, this dissertation presents a product reliability study based on low cost resources available in the companies, such as warranty data and experts’ qualitative analysis. The aim of this study is to develop a method to model the life cycle of systems and components, and demonstrate this method through a case study of agricultural equipment. This study presents a bibliographical review on reliability and qualitative analysis as well as other relevant subjects to support the method development. The study explores the company warranty data behavior, the Delphi methodology to obtain the experts’ opinions, and the multiplication of two Weibull distributions for the outcome consolidation. The main results presented are: the system reliability curve; the components failure analysis; and a method evaluation.
55

Was the Scots Common Law underlying contracts of sale unified in regard to the implied warranty of soundness?

Jayathilaka, Herath Mudiyanselage Chathuni January 2015 (has links)
The thesis explores whether, prior to the nineteenth century regime of legislative intervention which anglicised the law relating to contracts of sale for goods, the Scots common law underlying contracts of sale developed in a unitary fashion. Did the same principles apply regardless of whether the subject of the sale was corporeal moveable, corporeal immoveable or incorporeal? This question is analysed through a case study of the common law contractual implied warranty of soundness, and its application to the three types of property mentioned above. While this study does not provide a definitive answer on its own, it does give us a preliminary indication as to whether the law was unified or not. The thesis relies primarily on Scots case law and academic writings, employing historical and doctrinal methodologies. The study is supplemented by comparative law from France, Germany, South Africa and England. Roman law, and the works certain Ius Commune writers, are also referenced. The thesis can be divided into four parts. The first part explores whether academic texts on the contract of sale dating prior to the legislative intervention took a unified approach in their discussion. This establishes whether scholars from this period viewed the contract of sale as unified; and aids the analysis in subsequent chapters. The second part examines the warranty’s substantive framework in the context of its development, in the eighteenth and nineteenth centuries, through case law featuring corporeal moveable property. The third part looks at the warranty’s use in contracts of sale for corporeal immoveable property. Here, I establish that: 1) there was no consensus as to whether or not the warranty applied to this type of property; and 2) the warranty was not utilised by buyers of this type of property in practice. I identify a combination of factors which prevented buyers of latently defective corporeal immoveable property from invoking the warranty. The final part of the thesis examines the warranty’s actual and theoretical application to contracts of sale for incorporeal property. It establishes that the warranty would be relevant to some, but not all, types of incorporeal property.
56

Desenvolvimento de haste femoral não cimentada nacional, validada por normas internacionais

Macedo, Carlos Alberto de Souza January 2007 (has links)
O desenvolvimento de próteses nacionais de qualidade duvidosa e a insuficiência de normas e rotinas objetivas de garantia de qualidade de implantes médicos no país tornaram as próteses importadas sinônimo de qualidade, acarretando atraso tecnológico pontual nesta área no Brasil. O presente estudo é a aplicação de ensaios laboratoriais sugeridos pelo Food and Drug Administration (FDA) para revisão sistemática do processo de fabricação, material, características e desempenho de uma prótese de fêmur proximal não cimentada. Foram enfatisados os testes de aferição da qualidade e segurança do implante. O objetivo do estudo foi determinar a exeqüibilidade de desenvolvimento de uma prótese brasileira que atenda padrões internacionais de garantia de qualidade. Em 2001, a partir da idéia conceitual do autor, foi desenvolvido, com a ferramenta AutoCad 2000, um protótipo virtual de prótese de fêmur proximal em forma de dupla cunha quadrangular. A seguir utilizou-se o Método de Elementos Finitos (MEF), para simular o carregamento representado por um individuo de 120kg. As simulações da viabilidade mecânica do protótipo, em liga de titânio, demonstrou uma tensão de von Mises 8.1 vezes menor que a tensão necessária para atingir o ponto de escoamento do material. Uma vez aprovado o projeto virtual, a prótese foi fabricada e os primeiros protótipos e corpos-de-prova foram encaminhados aos Laboratórios de Caracterização para serem submetidos à revisão sistemática de ensaios e testes conforme normas da International Organization Standardization (ISO) e da American Society for Tchiniques and Materiasl (ASTM), segundo lista sugerida pelo FDA para validação da garantia de qualidade.Na determinação dos constituintes metálicos, os resultados dos testes expressos em percentuais foram de Fe=0,06%, Al=6,20%, V=3,57%, O=0,115%, N=0,003%, e H=0,010%, peso e valores dentro dos limites máximo e mínimo. Assim também, a composição química qualitativa e quantitativa do metal base bem como da camada porosa da prótese revelaram ausência de contaminações por metais pesados à espectrometria por energia dispersa (EDS), com picos concentrados em energias menores que 6 keV. Na avaliação das propriedades elásto-plásticas da amostra o valor médio de dureza foi de 4,45 (3,92 a 4,79) GPA e o módulo de elasticidade das amostras medidas variaram de 112,12 a 140,77 GPA (média=134,33 GPA). Na análise da rugosidade superficial, o coeficiente de rugosidade médio (DP) no cone foi de 0,60 (0,03) μm; na região jateada de 12,2 (0,8) μm e na ponta de 0,41 (0,01) μm. Na região porosa os valores pontuais variaram entre 15 e 30μm. No ensaio de fadiga com torção da prótese não foram observadas fissuras, fraturas, deformações ou afrouxamentos do meio de embutimento, assim como não houve alterações de medidas (deformação plástica) em nenhuma prótese analisada por microscopia eletrônica. No teste de corrosão da haste não ocorreu qualquer alteração do aspecto visual da superfície de teste após 64 dias de ensaio. Na análise granulométrica do pó do material depositado, conforme norma ASTM B 214-92 foi verificada predominância de partículas de tamanho variando entre 75μm e 180μm, correspondendo a 84% do total da amostra. A espessura da camada do material depositado apresentou valor médio de 52,7μm, mínimo de zero e máximo de 318 μm. A porosidade média foi de 16% (variando de 3% a 41%) e os poros apresentavam diâmetro médio de 88,5 μm e profundidade média de 28,2 μm. A força de adesão da camada porosa depositada revelou valores de 5 a 7 MPA na termo-aspersão realizada inicialmente. Posteriormente, após a modificação da técnica de aspersão, obteve-se valores entre 15 a 17 MPA, comparáveis aos valores da adesão referidos na literatura. Em todos os testes e ensaios acima descritos foram obtidos resultados de acordo com as normas e testes preconizados e padronizados internacionalmente para implantes metálicos em liga de titânio. Concluímos que é possível produzir uma prótese com tecnologia nacional de acordo com os padrões internacionais qualidade e segurança. / The development of national prostheses of doubtful quality and almost the absence of norms and routine quality control of medical implant devices in the country led to the belief of imported prostheses as a synonym of quality and safeness, resulting in a national technological impairment on this field. The present study is a systematic revision of the process of manufacturing a femoral prosthesis, for use without cement, with emphasis in tests assessing the design, quality and safeness of the implant. The aim of the study was to determine the feasibility of developing a Brazilian prosthesis would comply with international standards of quality assurance. On September, 2001 from the conception model idealized by the author, a virtual prototype of double tapered titanium femoral stem was developed with the AutoCad 2000 tool. After, the Finite Elements Model (FEM) was used for simulation and evaluation of the mechanical viability of the prototype and demonstrated a von Mises tension 8.1 folds lesser than needed to reach the deformation point of the material. Once manufactured the prosthesis, the first prototypes and sample parts for test were sent to the Laboratories of Characterization to be submitted to systematic revision of assays and tests in agreement with the norms from ISO and ASTM, as suggested by the FDA to validate the quality assurance of the non cemented prosthesis in titanium alloy. In determining the metallic components, the test results expressed in percentages were Fe=0.06%, Al=6.20%, V=3.57%, O=0.115%, N=0.003%, and H=0.010%, weight and values within the maximum and minimum established limits. Also, the qualitative and quantitative chemical composition of the basic metal as well as of the porous layer of the prosthesis have shown absence of any contamination due to heavy metals by energy dispersed spectrometry (EDS), with peaks concentrated in less than 6 keV. On evaluating the elasto-plastic properties of the sample the average value of hardness was 4.45 (3.92 to 4.79) GPA and the elasticity module of the measured samples varied from 112.12 to 140.77 GPA (mean=134.33 GPA). In the analysis of the superficial roughness, the average coefficient of roughness (dp) in the cone was 0.60 (0.03) μm; in the plasma spray coating region was 12.2 (0.8) μm and in the tip was 0.41 (0.01) μm. In the porous-coated region these values had varied between 15 and 30μm. In the assays for fatigue by twisting of prosthesis, breakings, deformations or loosening in the (specimen holder) have not been observed as well as alterations of measures (plastic deformation) in any prosthesis analyzed by electronic microscopy. On corrosion tests, no alteration of the visual aspect of the surface occurred after 64 days of assay. In the grain size analysis of the dust of the deposited material according to ASTM B 214-92 norm particle sizes predominantly varied between 75μm and 180μm; corresponding to 84% of the total of the sample. The thickness of the layer of the deposited material presented an average value of 52.7 μm (minimum of zero and maximum of 318 μm). The average porosity was 16% (varying from 3% to 41%) and the pores presented an average diameter of 88.5 μm and average depth of 28.2 μm. The force of adhesion of the deposited porous layer showed values of 5 to 7 MPA in the plasma spray coating process initially performed by a national company that later got values between 15 and 17 MPA, which were comparable to the values obtained when performed in a overseas company. Even though, all the tests and above described assays have demonstrated results in accordance with the norms and tests internationally recommended and standardized for metallic implants in titanium alloy. In conclusion, it is possible to produce a prosthesis with national technology in accordance with internationalstandards of design, quality and safeness. However, the national system of plasma spray needed adjustments to assure quality comparable to that of foreign companies.
57

Dados de garantia e análise qualitativa de especialistas como base para estudo de confiabilidade no setor de máquinas agrícolas

Bonetti, Lauro Viçosa January 2009 (has links)
Ultimamente as empresas têm buscado entender e aprimorar a confiabilidade de seus produtos para atender a crescente exigência dos clientes quanto à qualidade. Desta forma, as empresas também visam aumentar seus lucros, reduzir gastos com garantia e transmitir uma boa imagem de sua marca. Como contribuição a este tema, a presente dissertação apresenta um estudo de confiabilidade de um produto, baseado em recursos de baixo custo disponíveis nas empresas, os quais consistem os dados de garantia e a análise qualitativa dos especialistas. O objetivo do estudo representa desenvolver um método para modelar a vida útil de sistemas e componentes, e apresentar esta através da aplicação em um estudo de caso de certo equipamento agrícola. Para fundamentar a elaboração do método, o trabalho apresenta uma revisão bibliográfica sobre confiabilidade e análise qualitativa. O estudo explora o comportamento dos dados de garantia da empresa, a metodologia Delphi para obtenção da opinião dos especialistas, e a multiplicação de duas funções Weibull para consolidação dos resultados. Como principais resultados são apresentados: a curva de confiabilidade do sistema; o comportamento de falha dos componentes; e avaliação sobre o funcionamento do método. / Lately, companies have been urged to understand and improve their product reliability in order to meet the increasing costumer demand for quality. In doing so, the companies also aims at increasing its profits, reducing warranty claims’, and transmitting a good image of its brand. As a contribution to this subject, this dissertation presents a product reliability study based on low cost resources available in the companies, such as warranty data and experts’ qualitative analysis. The aim of this study is to develop a method to model the life cycle of systems and components, and demonstrate this method through a case study of agricultural equipment. This study presents a bibliographical review on reliability and qualitative analysis as well as other relevant subjects to support the method development. The study explores the company warranty data behavior, the Delphi methodology to obtain the experts’ opinions, and the multiplication of two Weibull distributions for the outcome consolidation. The main results presented are: the system reliability curve; the components failure analysis; and a method evaluation.
58

Desenvolvimento de haste femoral não cimentada nacional, validada por normas internacionais

Macedo, Carlos Alberto de Souza January 2007 (has links)
O desenvolvimento de próteses nacionais de qualidade duvidosa e a insuficiência de normas e rotinas objetivas de garantia de qualidade de implantes médicos no país tornaram as próteses importadas sinônimo de qualidade, acarretando atraso tecnológico pontual nesta área no Brasil. O presente estudo é a aplicação de ensaios laboratoriais sugeridos pelo Food and Drug Administration (FDA) para revisão sistemática do processo de fabricação, material, características e desempenho de uma prótese de fêmur proximal não cimentada. Foram enfatisados os testes de aferição da qualidade e segurança do implante. O objetivo do estudo foi determinar a exeqüibilidade de desenvolvimento de uma prótese brasileira que atenda padrões internacionais de garantia de qualidade. Em 2001, a partir da idéia conceitual do autor, foi desenvolvido, com a ferramenta AutoCad 2000, um protótipo virtual de prótese de fêmur proximal em forma de dupla cunha quadrangular. A seguir utilizou-se o Método de Elementos Finitos (MEF), para simular o carregamento representado por um individuo de 120kg. As simulações da viabilidade mecânica do protótipo, em liga de titânio, demonstrou uma tensão de von Mises 8.1 vezes menor que a tensão necessária para atingir o ponto de escoamento do material. Uma vez aprovado o projeto virtual, a prótese foi fabricada e os primeiros protótipos e corpos-de-prova foram encaminhados aos Laboratórios de Caracterização para serem submetidos à revisão sistemática de ensaios e testes conforme normas da International Organization Standardization (ISO) e da American Society for Tchiniques and Materiasl (ASTM), segundo lista sugerida pelo FDA para validação da garantia de qualidade.Na determinação dos constituintes metálicos, os resultados dos testes expressos em percentuais foram de Fe=0,06%, Al=6,20%, V=3,57%, O=0,115%, N=0,003%, e H=0,010%, peso e valores dentro dos limites máximo e mínimo. Assim também, a composição química qualitativa e quantitativa do metal base bem como da camada porosa da prótese revelaram ausência de contaminações por metais pesados à espectrometria por energia dispersa (EDS), com picos concentrados em energias menores que 6 keV. Na avaliação das propriedades elásto-plásticas da amostra o valor médio de dureza foi de 4,45 (3,92 a 4,79) GPA e o módulo de elasticidade das amostras medidas variaram de 112,12 a 140,77 GPA (média=134,33 GPA). Na análise da rugosidade superficial, o coeficiente de rugosidade médio (DP) no cone foi de 0,60 (0,03) μm; na região jateada de 12,2 (0,8) μm e na ponta de 0,41 (0,01) μm. Na região porosa os valores pontuais variaram entre 15 e 30μm. No ensaio de fadiga com torção da prótese não foram observadas fissuras, fraturas, deformações ou afrouxamentos do meio de embutimento, assim como não houve alterações de medidas (deformação plástica) em nenhuma prótese analisada por microscopia eletrônica. No teste de corrosão da haste não ocorreu qualquer alteração do aspecto visual da superfície de teste após 64 dias de ensaio. Na análise granulométrica do pó do material depositado, conforme norma ASTM B 214-92 foi verificada predominância de partículas de tamanho variando entre 75μm e 180μm, correspondendo a 84% do total da amostra. A espessura da camada do material depositado apresentou valor médio de 52,7μm, mínimo de zero e máximo de 318 μm. A porosidade média foi de 16% (variando de 3% a 41%) e os poros apresentavam diâmetro médio de 88,5 μm e profundidade média de 28,2 μm. A força de adesão da camada porosa depositada revelou valores de 5 a 7 MPA na termo-aspersão realizada inicialmente. Posteriormente, após a modificação da técnica de aspersão, obteve-se valores entre 15 a 17 MPA, comparáveis aos valores da adesão referidos na literatura. Em todos os testes e ensaios acima descritos foram obtidos resultados de acordo com as normas e testes preconizados e padronizados internacionalmente para implantes metálicos em liga de titânio. Concluímos que é possível produzir uma prótese com tecnologia nacional de acordo com os padrões internacionais qualidade e segurança. / The development of national prostheses of doubtful quality and almost the absence of norms and routine quality control of medical implant devices in the country led to the belief of imported prostheses as a synonym of quality and safeness, resulting in a national technological impairment on this field. The present study is a systematic revision of the process of manufacturing a femoral prosthesis, for use without cement, with emphasis in tests assessing the design, quality and safeness of the implant. The aim of the study was to determine the feasibility of developing a Brazilian prosthesis would comply with international standards of quality assurance. On September, 2001 from the conception model idealized by the author, a virtual prototype of double tapered titanium femoral stem was developed with the AutoCad 2000 tool. After, the Finite Elements Model (FEM) was used for simulation and evaluation of the mechanical viability of the prototype and demonstrated a von Mises tension 8.1 folds lesser than needed to reach the deformation point of the material. Once manufactured the prosthesis, the first prototypes and sample parts for test were sent to the Laboratories of Characterization to be submitted to systematic revision of assays and tests in agreement with the norms from ISO and ASTM, as suggested by the FDA to validate the quality assurance of the non cemented prosthesis in titanium alloy. In determining the metallic components, the test results expressed in percentages were Fe=0.06%, Al=6.20%, V=3.57%, O=0.115%, N=0.003%, and H=0.010%, weight and values within the maximum and minimum established limits. Also, the qualitative and quantitative chemical composition of the basic metal as well as of the porous layer of the prosthesis have shown absence of any contamination due to heavy metals by energy dispersed spectrometry (EDS), with peaks concentrated in less than 6 keV. On evaluating the elasto-plastic properties of the sample the average value of hardness was 4.45 (3.92 to 4.79) GPA and the elasticity module of the measured samples varied from 112.12 to 140.77 GPA (mean=134.33 GPA). In the analysis of the superficial roughness, the average coefficient of roughness (dp) in the cone was 0.60 (0.03) μm; in the plasma spray coating region was 12.2 (0.8) μm and in the tip was 0.41 (0.01) μm. In the porous-coated region these values had varied between 15 and 30μm. In the assays for fatigue by twisting of prosthesis, breakings, deformations or loosening in the (specimen holder) have not been observed as well as alterations of measures (plastic deformation) in any prosthesis analyzed by electronic microscopy. On corrosion tests, no alteration of the visual aspect of the surface occurred after 64 days of assay. In the grain size analysis of the dust of the deposited material according to ASTM B 214-92 norm particle sizes predominantly varied between 75μm and 180μm; corresponding to 84% of the total of the sample. The thickness of the layer of the deposited material presented an average value of 52.7 μm (minimum of zero and maximum of 318 μm). The average porosity was 16% (varying from 3% to 41%) and the pores presented an average diameter of 88.5 μm and average depth of 28.2 μm. The force of adhesion of the deposited porous layer showed values of 5 to 7 MPA in the plasma spray coating process initially performed by a national company that later got values between 15 and 17 MPA, which were comparable to the values obtained when performed in a overseas company. Even though, all the tests and above described assays have demonstrated results in accordance with the norms and tests internationally recommended and standardized for metallic implants in titanium alloy. In conclusion, it is possible to produce a prosthesis with national technology in accordance with internationalstandards of design, quality and safeness. However, the national system of plasma spray needed adjustments to assure quality comparable to that of foreign companies.
59

Nexos semânticos em certificados de garantia

Estrela, Kênio Angelo Dantas Freitas 27 February 2015 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2017-03-24T11:44:00Z No. of bitstreams: 1 arquivototal.pdf: 10006758 bytes, checksum: c4170c1bdaf8a5690d1f12d19b8f7e7d (MD5) / Made available in DSpace on 2017-03-24T11:44:00Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 10006758 bytes, checksum: c4170c1bdaf8a5690d1f12d19b8f7e7d (MD5) Previous issue date: 2015-02-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The study of the meaning of relations between sentences is a much discussed and researched field in linguistic studies. The observation of how the terms behave in the construction of meanings in texts of different genres and their interpretation effects are also widespread themes among semantic research. In this work we will discuss about the meaning of the relations of meaning and their sense of purpose in a specific genre. The relations that we will investigate are semantic nexus or semantic links, as proposed by Chierchia (2003), which are respectively: entailment, semantic equivalence, contradictoriness and contrariness. The genre we chose for our analysis is the warranty certificate and the choice of this genre was made because it is part of the injunctive or instructional texts group that, in our opinion, has characteristics that favor the sampling of semantic nexus. We will analyze how the semantic nexus are used to restrict or cover the possibilities of interpretation in the warranty certificates. The corpus of this research has 22 (twenty two) copies of warranty certificates from different segments and we decided to choose certificates from separate lines to constitute an overview of the genre. The collection of the texts took place through the internet, without using any particular methodology of choice, only we pay attention to seek warranty certificates of diverse products. We seek in this research instigate reflection on the meaning relations between sentences and observance of these in instructional texts that we have contact in daily life and that, for many times, let go unnoticed its contents. The understanding of the semantic nexus can offer us tools to better read texts of this type. / O estudo das relações de significado entre sentenças é um campo bastante discutido e pesquisado nos estudos linguísticos. A observação de como se comportam os termos na construção de significados em textos de diversos gêneros e seus efeitos de interpretação também são temas muito difundidos entre as pesquisas das semânticas. Nesta produção discutiremos sobre as relações de significado e seus efeitos de sentido em um gênero específico. As relações que investigaremos são os nexos semânticos ou nexos de significado, como proposto por Chierchia (2003) que são respectivamente: acarretamento, equivalência semântica, contraditoriedade e contrariedade. O gênero que escolhemos para nossa análise é o certificado de garantia e a escolha de tal gênero se deu pelo fato deste fazer parte do grupo de textos injuntivos ou instrucionais que, a nosso ver, possui características que favorecem a amostragem dos nexos semânticos. Iremos analisar como os nexos semânticos são utilizados para restringir ou abranger as possibilidades de interpretação nos certificados de garantia. O corpus desta pesquisa conta com 22 (vinte e dois) exemplares de certificados de garantia de produtos de diversos segmentos e decidimos escolher certificados de produtos de linhas diversas para constituirmos um panorama sobre o gênero. A coleta dos textos se deu através da internet, sem utilizar nenhuma metodologia específica, apenas atentamos para buscar certificados de produtos variados. Buscamos nessa pesquisa instigar a reflexão sobre as relações de significado entre sentenças e a observação destas nos textos instrucionais que lidamos no dia-a-dia e que, por muitas vezes, deixamos passar despercebido o seu conteúdo. O entendimento sobre os nexos de significado pode nos oferecer ferramentas para melhor leitura de textos desse tipo.
60

Možnosti získání finančních prostředků z programů podpor MSP pro malý podnik / Possibility of obtaining funding from the SME support for small company

KUNKELA, Martin January 2010 (has links)
The main objective of this thesis is an analysis of support programs focused on small businesses, the program most suitable applications for the enterprise and assess the contribution of selected operational program for the examinees.

Page generated in 0.0533 seconds