• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 74
  • 66
  • 15
  • 11
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 217
  • 63
  • 58
  • 34
  • 31
  • 21
  • 20
  • 18
  • 16
  • 15
  • 14
  • 14
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Flexibility studies on chrome alloy wires and appliances submitted in partial fulfilllment ... orthodontics /

Grant, Joseph O. January 1942 (has links)
Thesis (M.S.)--University of Michigan, 1942.
92

Corrosion between orthodontic archwires and bracket couples

O'Leary, Brian C. January 2000 (has links)
Thesis (M.S.)--West Virginia University, 2000. / Title from document title page. Document formatted into pages; contains viii, 94 p. : ill. Vita. Includes abstract. Includes bibliographical references (p. 46-49).
93

Efeito do tratamento térmico nos fios ortodônticos de aço inoxidável /

Kasbergen, Geraldo Francisco. January 2007 (has links)
Resumo: O objetivo deste trabalho foi avaliar o efeito do tratamento térmico (ou revenido) nos fios ortodônticos de aço inoxidável de Cromo Níquel (CrNi). Foram utilizados 40 arcos das espessuras 0.014"(0,35mm), 0.016"(0,40mm), 0.018"(0,45mm) e 0.020"(0,50mm). Os arcos foram divididos nos grupos sem e com tratamento térmico e, posteriormente, mensurados nas regiões anterior e posterior por meio do "software" AutoCad 2000 antes e após os ensaios mecânicos de compressão e tração por meio da máquina de ensaio universal EMIC. Os resultados foram submetidos à análise estatística com teste de multivariância ANOVA em nível de 5% (p<0,05). Diante da metodologia utilizada neste estudo, pode-se concluir que os arcos ortodônticos tratados termicamente apresentam suaves modificações transversais na região anterior e maiores aumentos transversais na região posterior, porém, provavelmente, sem relevância clínica. Os arcos sem e com tratamento térmico submetidos à força de compressão não apresentaram alterações transversais significantes nas regiões anterior e posterior. Nos arcos sem tratamento térmico submetidos à força de tração ocorreram aberturas mais acentuadas na região anterior nos arcos 0.020". Na região posterior, a abertura proporcionada pela tração ocorreu com maior intensidade nos arcos sem tratamento térmico. Os arcos com tratamento térmico submetidos à força de tração não alteraram a distância transversal na região anterior. Nos arcos tratados termicamente constatou-se uma maior estabiidade, principalmente quando submetidos à tração ou à abertura. / Abstract: The aim of this study was to evaluate the effect of heat treatment in orthodontic wires of Chrome Nickel (CrNi) stainless steel. 40 arches of 0.014" (0,35 mm), 0.016" (0.40 mm), 0.018 "(0.45 mm) and 0.020" (0.50 mm) were used. The arches were divided 2 groups: with and without heat treatment and then measured in anterior and posterior regions using AutoCad 2000 software before and after tension and compression tests, using universal testing machine EMIC. The results were submitted to ANOVA multivariance test for statistical analysis with level of 5% (p<0.05). Through the methodology used in this study it can be concluded that the orthodontic arches with heat treatment presented soft transversal changes in the anterior region and larger transversal increases in the posterior region, probably without clinical relevance. The arches with and without heat treatment submited to compression force did not show significant transversal changes in the anterior and posterior regions. The arches 0.020" without heat treatment submited to traction force presented the largest increases in width in the anterior region. Traction force at posterior region led to arch openning with greater intensity in arches without heat treatment. The arches with heat treatment submited to traction force didn't change the transversal distance in the anterior region. It was found that arches with heat treatment had greater stability, especially when submitted to traction or opening forces. / Orientador: Osmar Aparecido Cuoghi / Coorientador: Paulo Henrique dos Santos / Banca: Adilson Luiz Ramos / Banca: Marcos Rogério de Mendonça / Mestre
94

Fabricação e caracterização de fios supercondutores do sistema BSCCO pelo método Powder-In-Tube (PIT) /

Souza, Élton José de. January 2011 (has links)
Orientador: Cláudio Luiz Carvalho / Banca: Haroldo Naoyuki Nagashima / Banca: Isaias Gonzaga de Oliveira / Resumo: Com o surgimento da supercondutividade as pesquisas envolvendo aplicações desta, em especial no transporte de energia, obtiveram um avanço promissor ao longo dos anos. Assim, este trabalho objetivou a fabricação de fios supercondutores utilizando o método Powder-In-Tube (PIT), no qual foi inserido dentro de um tubo de prata o pó da cerâmica supercondutora do sistema BSCCO. Estudos preliminares foram feitos em pastilhas feitas com o mesmo material supercondutor e após alguns resultados foram confeccionados os fios supercondutores. Medidas de caracterização foram feitas dentre elas a difratometria de raios-X, medidas elétricas pelo método de quatro pontas e microscopia do tipo (FEG-MEV) equipado com EDS para determinar a morfologia e composição química dos elementos na amostra. Os resultados de difratometria de raios-X apresentaram a formação das fases desejadas do sistema BSCCO de diferentes concentrações dentre elas as fases Bi-2212 Bi- 2223 e Bi-2234 contidas nas amostras sintetizadas. As medidas elétricas detectaram uma queda abrupta na resistência elétrica dos fios mostrando a faixa de transição supercondutora das amostras estudadas. As medidas de densidade de corrente com base no critério de corrente de 1μV/cm, utilizadas nos fios confeccionados, foram obtidos valores da ordem de 1,30 - 3,90 (KA/m2). Nas imagens de microscopia vale ressaltar uma melhora na interação entre os grãos supercondutores nas amostras submetidas a um maior tempo de sinterização e também foi possível verificar e analisar através da extrusão a compactação do pó cerâmico dentro do tubo de prata. O EDS detectou a composição química dos elementos nas amostras bem como a concentração das fases em determinadas regiões analisadas / Abstract: With the emergence of superconductivity research involving applications of this, particularly in the transport of energy, had a promising advance over the years. This study aims to manufacture superconducting wires using the method Powder-In-Tube (PIT), which was inserted inside a tube of silver powder of superconducting ceramic BSCCO system. Preliminary studies were done on pellets made with the same superconducting material, and after some results were prepared the superconducting wires. Characterization measurements were made among them the X-ray diffraction, electrical measurements by the method of four points and type of microscopy (FEG-SEM) equipped with EDX to determine the morphology and chemical composition of the elements in the sample. The results of X-ray diffraction showed the formation of the desired phases for this type of superconductor, ie the BSCCO system between them was possible to determine the Bi-2212 phase, Bi-2223 and Bi-2234 contained in the synthesized samples. The electrical measurements have detected a sudden drop in electrical resistance of the wires showing the range of superconducting transition with good accuracy. It was possible to perform the calculation of current density in the wires made based on a criterion of 1 μV/cm were obtained and values of around 1,30- 3,90 (KA/m2). The values are consistent with the specifications of the samples and within the limits of our research. In microscopy images is noteworthy improvement in the interaction between the superconducting grains in samples submitted to a higher sintering time and it was possible to verify and analyze the compaction of ceramic powder into silver tube through the extrusion process. The EDX detected the chemical composition of the elements in the samples in a qualitative way / Mestre
95

Análise microscópica e da rugosidade de superfície de fios ortodônticos estéticos, antes e após deflexão / Microscopic analysis and surface roughness of aesthetic orthodontic wires before and after deflection

Pedro, Adriana Correia 25 April 2011 (has links)
Submitted by Noeme Timbo (noeme.timbo@metodista.br) on 2017-05-24T18:20:17Z No. of bitstreams: 8 Adriana Correia pag 1 - 30.pdf: 478369 bytes, checksum: ae6323176f9acdf91b9fe5c7217f35f3 (MD5) Adriana Correia pag 31 - 41.pdf: 178789 bytes, checksum: a8a9146174ae94167e7ed531819e1d18 (MD5) Adriana Correia pag 42 - 46.pdf: 392333 bytes, checksum: ee34f08401a46c70e9776ba4e5d40486 (MD5) Adriana Correia pag 47 - 52.pdf: 464089 bytes, checksum: f520d878ebeb9d1950bacff15996338e (MD5) Adriana Correia pag 53 - 63.pdf: 199749 bytes, checksum: 16f21d73c539e390b96bfb6f4520fdd5 (MD5) Adriana Correia pag 64 - 68.pdf: 715356 bytes, checksum: 93f1263a3ff487d258795b8b44cdd3d9 (MD5) Adriana Correia pag 69 - 74.pdf: 368552 bytes, checksum: b41de0756f26e159de63ae8844efc138 (MD5) Adriana Correia pag 75 - 89.pdf: 137157 bytes, checksum: 9070f8b63968e83ef5ce6a2d5cf10e43 (MD5) / Made available in DSpace on 2017-05-24T18:20:18Z (GMT). No. of bitstreams: 8 Adriana Correia pag 1 - 30.pdf: 478369 bytes, checksum: ae6323176f9acdf91b9fe5c7217f35f3 (MD5) Adriana Correia pag 31 - 41.pdf: 178789 bytes, checksum: a8a9146174ae94167e7ed531819e1d18 (MD5) Adriana Correia pag 42 - 46.pdf: 392333 bytes, checksum: ee34f08401a46c70e9776ba4e5d40486 (MD5) Adriana Correia pag 47 - 52.pdf: 464089 bytes, checksum: f520d878ebeb9d1950bacff15996338e (MD5) Adriana Correia pag 53 - 63.pdf: 199749 bytes, checksum: 16f21d73c539e390b96bfb6f4520fdd5 (MD5) Adriana Correia pag 64 - 68.pdf: 715356 bytes, checksum: 93f1263a3ff487d258795b8b44cdd3d9 (MD5) Adriana Correia pag 69 - 74.pdf: 368552 bytes, checksum: b41de0756f26e159de63ae8844efc138 (MD5) Adriana Correia pag 75 - 89.pdf: 137157 bytes, checksum: 9070f8b63968e83ef5ce6a2d5cf10e43 (MD5) Previous issue date: 2011-04-25 / The objective of this study was to evaluate the surface topography of the aesthetic yarn before and after the deflection test. The sample consisted of 70 round 0.014h test leads, 10 of each of the evaluated brands: Orthocosmetic Elastinol (Masel), Flexy Super Elastic Esthetic (Orthometric), InVu (TP Orthodontics) and ProForm Nitanium (Ortho Organizers ). Teflon® coated NiTi wires; Optis (TP Orthodontics). Fiberglass-reinforced resin wire or FRP; Niticosmetic (Tecnident). NiTi yarn coated with epoxy resin; And Nitinol SE (3M Unitek). Superelastic NiTi wire, used for control. The surface topography of each wire was evaluated by a rugosimetre and by an optical microscope, before and after being subjected to a deflection test, on the side where the force was applied and on the opposite side. Each wire was deflected in 3.1mm, at a speed of 1mm / min, with a load cell of 5N at 36.C + 1.C. The analysis of variance at three criteria (p <0.05) showed significant difference between the strands and the Tukey test showed that the Optis (TP Orthodontics) wire presented increase in the roughness parameters Ra, Rt and Rz, after the deflection. / O objetivo deste estudo foi avaliar a topografia de superficie dos fios esteticos, antes e apos teste de deflexao. A amostra foi composta por 70 corpos de prova de fios 0,014h redondos, sendo 10 de cada uma das marcas comerciais avaliadas: Orthocosmetic Elastinol (Masel), Flexy Super Elastic Esthetic (Orthometric), InVu (TP Orthodontics) e ProForm Nitanium (Ortho Organizers) . fios de NiTi revestidos por TeflonR; Optis (TP Orthodontics) . fio de resina reforcado por fibra de vidro ou FRP; Niticosmetic (Tecnident) . fio de NiTi revestido por resina epoxidica; e Nitinol SE (3M Unitek) . fio de NiTi superelastico, usado para controle. A topografia de superficie de cada fio foi avaliada por rugosimetro e por microscopio optico, antes e apos ser submetido a ensaio de deflexao, no lado em que a forca foi aplicada e no lado oposto a este. Cada fio foi defletido em 3,1mm, a uma velocidade de 1mm/min, com celula de carga de 5N a 36.C + 1.C. A analise de variancia a tres criterios (p<0,05) mostrou diferenca significante entre os fios e o teste de Tukey mostrou que o fio Optis (TP Orthodontics) apresentou aumento nos parametros de rugosidade Ra, Rt e Rz, apos a deflexao. O fio Niticosmetic (Tecnident) apresentou aumento na rugosidade media (Ra). O fio InVu (TP Orthodontics) foi o unico que mostrou aumento na rugosidade no lado em que a forca foi aplicada. A analise visual por meio de microscopia optica revelou alteracoes na superficie em todos os fios esteticos apos o teste de deflexao, desde delaminacoes do revestimento, observadas nos fios Orthocosmetic Elastinol e InVu, riscos permanentes na superficie, como visto nos fios Flexy Super Elastic Esthetic, Niticosmetic e ProForm Nitanium, e ate mesmo fratura incompleta, no fio Optis. Concluiu-se que o fio Niticosmetic apresentou topografia de superficie similar ao fio metalico, e os demais fios esteticos apresentaram maior rugosidade e alteracoes visuais na superficie.
96

Estudo dos efeitos do método de produção em aciaria nas propriedades mecânicas de produtos trefilados a partir de aço semelhante ao SAE 1045

Vares, João Vinícius de Souza January 2016 (has links)
O mercado siderúrgico vive um momento de grande competição e as empresas produtoras necessitam, cada vez mais, atuar internamente sobre seus custos para garantir lucratividade e rentabilidade. A motivação deste trabalho foi a redução de custos de produção de arames de aço para o setor agropecuário, por meio de estudo de viabilidade técnica do emprego de aço ao carbono produzido via aciaria elétrica, em lugar de aço produzido via aciaria a oxigênio – atualmente utilizado em algumas usinas siderúrgicas. As qualidades de aços estudadas são produzidas através de aciaria elétrica, dando origem aos tarugos que são laminados a quente para obtenção do fio-máquina que segue para os processos posteriores de trefilação e galvanização, em que se obtém os arames de aço. As composições químicas propostas neste trabalho devem garantir que as especificações de propriedades mecânicas permaneçam sendo atendidas. Foram realizados levantamento e análise de histórico de dados, análises de composição química, caracterização microestrutural, ensaios de tração e de enrolamento. Fundamentado nos resultados atingidos, mostra-se que a metodologia proposta para avaliação de propriedades mecânicas é válida. O presente estudo aponta também que é viável tecnicamente o emprego de aço ao carbono semelhante ao SAE1045, obtido via aciaria elétrica, na produção de arames de aço galvanizados para o setor agropecuário, mantendo o atendimento a todas as especificações e com possibilidade de redução de custos de produção. / The steel market is experiencing a period of great competition and manufacturing companies need, increasingly, to act internally on their costs to ensure lucrativeness and profitability. The motivation of this work was to reduce the cost of production of steel wires for the agriculture sector, by studying the technical feasibility use of a carbon steel produced by electric arc furnace, replacing the oxygen furnace steel – currently used in some mills. The studied steels are manufactured in an electric arc furnace, giving rise to the billets that are hot rolled to obtain the wire rod to follow the subsequent process of drawing and galvanizing, where the wires of steel are made. The chemical compositions proposed in this paper must guarantee that the mechanical properties described in the technical standards continue be met. Data, chemical composition, microstructure, tensile strength and winding properties were surveyed and analyzed. Based upon the results achieved, it is shown that the proposed method for assessment of the mechanical properties is valid. This study also indicates that it is technically feasible the use of carbon steel similar to SAE1045, obtained by electric arc furnace, to manufacturing galvanized steel wires for the agriculture sector maintaining compliance to all technical standards and with the possibility of reducing costs.
97

ANÁLISE MICROSCÓPICA E DA RUGOSIDADE DE SUPERFÍCIE DE FIOS ORTODÔNTICOS ESTÉTICOS, ANTES E APÓS DEFLEXÃO

Pedro, Adriana Correia 25 April 2011 (has links)
Made available in DSpace on 2016-08-03T16:31:17Z (GMT). No. of bitstreams: 1 Adriana Correia pag 1 - 30.pdf: 478369 bytes, checksum: ae6323176f9acdf91b9fe5c7217f35f3 (MD5) Previous issue date: 2011-04-25 / The aim of this study was evaluate surface topography of esthetic orthodontic wires, before and after three-point bending test. The sample consisted of 70 lenghts of wires 0,014 round section, 10 of which commercial brand assessed: Orthocosmetic Elastinol (Masel), Flexy Super Elastic Esthetic (Orthometric), InVu (TP Orthodontics) and ProForm Nitanium (Ortho Organizers) Teflon® coated NiTi wires; Optis (TP Orthodontics) a fiber-reinforced plastic orthodontic wire named FRP; Niticosmetic (Tecnident) epoxy resin-coated NiTi wire; and Nitinol SE (3M Unitek) uncoated NiTi wire, used as control group. Surface topography of each wire was measured with a contact stylus perfilometer and with optical microscope, before and after being submitted to deflection, on side force was applied and on the opposite side. Each wire was 3,1mm deflected, at a speed of 1mm/min, with a 5N load cell, at 36&#8304;C + 1&#8304;C. Three criteria variance analysis (p<0,05) showed significant difference between assessed wires and Tukey s test showed Optis wire (TP Orthodontics) had increased parameters Ra, Rt and Rz mean values, after deflection. Niticosmetic (Tecnident) wire had increased average roughness (Ra) values. InVu (TP Orthodontics) was the only wire that showed greater values of roughness, on the side force was applied. Visual analysis with optical microscopy revealed surface alterations in all esthetic wires evaluated, after three-point bending test, since coating delamination, observed in Orthocosmetic Elastinol and InVu wires, permanent risks on surface, as seen in Flexy Super Elastic Esthetic, Niticosmetic and ProForm Nitanium, and even incomplete fracture, as in Optis wire. This study concluded that Niticosmetic wire showed similar surface topography to uncoated NiTi wire, and the other esthetic wires assessed had greater roughness and visual surface alterations. / O objetivo deste estudo foi avaliar a topografia de superfície dos fios estéticos, antes e após teste de deflexão. A amostra foi composta por 70 corpos de prova de fios 0,014 redondos, sendo 10 de cada uma das marcas comerciais avaliadas: Orthocosmetic Elastinol (Masel), Flexy Super Elastic Esthetic (Orthometric), InVu (TP Orthodontics) e ProForm Nitanium (Ortho Organizers) fios de NiTi revestidos por Teflon®; Optis (TP Orthodontics) fio de resina reforçado por fibra de vidro ou FRP; Niticosmetic (Tecnident) fio de NiTi revestido por resina epoxídica; e Nitinol SE (3M Unitek) fio de NiTi superelástico, usado para controle. A topografia de superfície de cada fio foi avaliada por rugosímetro e por microscópio óptico, antes e após ser submetido a ensaio de deflexão, no lado em que a força foi aplicada e no lado oposto a este. Cada fio foi defletido em 3,1mm, a uma velocidade de 1mm/min, com célula de carga de 5N a 36&#8304;C + 1&#8304;C. A análise de variância a três critérios (p<0,05) mostrou diferença significante entre os fios e o teste de Tukey mostrou que o fio Optis (TP Orthodontics) apresentou aumento nos parâmetros de rugosidade Ra, Rt e Rz, após a deflexão. O fio Niticosmetic (Tecnident) apresentou aumento na rugosidade média (Ra). O fio InVu (TP Orthodontics) foi o único que mostrou aumento na rugosidade no lado em que a força foi aplicada. A análise visual por meio de microscopia óptica revelou alterações na superfície em todos os fios estéticos após o teste de deflexão, desde delaminações do revestimento, observadas nos fios Orthocosmetic Elastinol e InVu, riscos permanentes na superfície, como visto nos fios Flexy Super Elastic Esthetic, Niticosmetic e ProForm Nitanium, e até mesmo fratura incompleta, no fio Optis. Concluiu-se que o fio Niticosmetic apresentou topografia de superfície similar ao fio metálico, e os demais fios estéticos apresentaram maior rugosidade e alterações visuaisna superfície.
98

Propriedades mecânicas de fios estéticos obtidas em ensaios de tração / Mechanical properties of esthetic orthodontic wires obtained through stress-strain tests

Cristiane Canavarro Rodrigues Martins 21 September 2007 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / O desenvolvimento de fios ortodônticos que associem a vantagem estética com as necessidades biomecânicas tem sido um dos objetivos na Ortodontia. A maioria dos fios comercializados com finalidade estética são compostos por níquel-titânio (NiTi) com cobertura a base de teflon ou resina epoxídica. O objetivo deste trabalho foi avaliar, através de ensaios de tração, propriedades mecânicas dos fios ortodônticos estéticos, em relação aos de NiTi superelásticos tradicionais. Foram utilizados 36 fios ortodônticos de NiTi superelásticos, sendo 18 estéticos e 18 sem cobertura estética, de calibre 0,018, das marcas TP Orthodontics, GAC e Masel. Os três exemplares de cada grupo foram alongados até a ruptura, com velocidade de ensaio de 1 milímetro de estiramento por minuto, a fim de se obter os patamares constantes de ativação dos fios. Os ensaios foram realizados a uma temperatura de 37C, utilizando-se a máquina universal de ensaios Emic DL 10000 de 10 toneladas de capacidade, sendo utilizada uma célula de carga de 50 N (50 quilogramas). Os dados foram analisados estatisticamente aplicando-se a análise de variância (ANOVA), seguido pelo teste de Bonferroni. Os resultados mostraram que, de maneira geral, os fios não recobertos possuem cargas máximas de ruptura e cargas para atingir o patamar de ativação mais elevadas que os estéticos (p&#8804; 0,01), com exceção dos fios não recobertos da marca Masel que apresentam semelhança estatística com os estéticos da TP. O mesmo acontece com as cargas no início, em 2% e 4% de deformação nos patamares de ativação e desativação. Os fios estéticos apresentaram, nos testes de ruptura, extensão de patamares de ativação maiores (p&#8804; 0,01), sendo o mesmo observado nos testes de ativação e desativação com extensão dos patamares de carregamento e descarregamento mais elevados. Em relação à área sob as curvas de ativação não foi observada diferença estatística significativa entre os fios avaliados com exceção dos fios da marca TP não recobertos, que apresentaram valores mais elevados. A área sob as curvas de desativação apresentaram valores maiores para os fios GAC não recobertos e TP estéticos e não recobertos (estatisticamente semelhantes) e valores mais baixos para os fios GAC estéticos e Masel estéticos e não recobertos. Conclui-se que em relação às características mecânicas os fios estéticos apresentaram bom desempenho, superando em grande parte das avaliações as características dos fios não recobertos. / The development of orthodontic wires that offer esthetic advantage with biomechanical necessities has been one of the aims of Orthodontics. Most of the wires with esthetic purpose are made of nickel-titanium (NiTi) with Teflon or epoxy-resin coating. This studys aims were to evaluate, through stress-strain tests, mechanical properties of the esthetic orthodontic wires, comparing them to the traditional NiTi superelastic ones. 36 superelastic NiTi orthodontic wires 18 esthetic and 18 with no esthetic coating with a 0,018 caliber, from the brands TP Orthodontics, GAC e Masel were used. The three samples of each group were extended till fracture, with a testing speed of 1 millimeter of extending per minute, with the purpose of obtaining constant plateaus of wire activation. The tests were made on a temperature of 37C, using the universal testing EMIC DL 10000 with 10 tons of capacity, and a 50N (50 kilograms) charging cell. The datas were analyzed statistically using the analysis of variance (ANOVA), followed by the Bonferroni test. The results proved that, in general, the uncoated wires have higher maximum fracture resistance charges and more elevated charges to reach loading plateau (p&#8804; 0,01) than the esthetic ones, with the exception of the uncoated Masel wires, which were statistically similar to esthetic TP wires. The same was observed with the charges in the beginning, with a 2% and 4% deforming on the loading and unloading plateaus. The esthetic wires presented, on the rupture tests, higher extension of loading plateaus than the esthetic ones (p&#8804; 0,01). The same was observed on the activation and deactivation tests with a higher extension of the loading and unloading plateaus. In the area under the activation curves no statistically relevant difference was observed on the valuated wires with the exception of the uncoated wires from TP, which showed more elevated values. The area under the deactivation curves presented higher values on the uncoated and esthetic GAC wires and uncoated TP wires (statistically similar) and lower values to the esthetic GAC and esthetic and uncoated Masel wires.
99

Fabrication et propriétés physiques de conducteurs multifilamentaires MgB2 dopés au carbone / Fabrication and superconducting properties of multifilamentary MgB2 wires with nanocarbon-based doping by using powder-in-tube method

Wang, Qingyang 25 September 2012 (has links)
Des conducteurs mono- et multi-filamentaires de MgB2 dans une gaine de Nb/Cu ont été élaborés par la technique PIT (powder in tube) avec des dopages de carbone et de TiC. Les résultats montrent qu'il y a une couche de diffusion non supraconductrice à l'interface entre le Nb et MgB2 pour les échantillons traités à haute température, couche qui empêche la pénétration du courant dans le conducteur. Les traitements thermiques doivent être inférieurs à 750°C. Les effets des dopages au carbone amorphe et au TiC ont été étudiés par XRD,MEB et aimantation. La substitution du bore par du carbone diminue légèrement la Tc mais augmente la piégeage des vortex, conduisant à un optimum du courant critique. Des multi-filaments de 6, 12 et 36 filaments sans dopage ont été élaborés par la technique PIT. Les propriétés mécaniques de ces conducteurs ont été renforcées en utilisant un filament central en Nb. L'assemblage MgB2/Nb/Cu est très adapté pour obtenir de grandes longueurs de conducteurs par la méthode PIT. / The mono-filamentary and multi-filamentary MgB2 wires sheathed with Nb/Cu composite tube were fabricated by in-situ powder-in-tube (PIT) technique with the carbon and TiC doping. The results show that there is a diffusion layer at the interfacial region between the Nb sheath and MgB2, which is non-superconducting phase for the sample heat-treated at high temperature, and this diffusion layer obstructs the current transmission at high heat-treatment temperatures and the best heat-treatment temperature for the MgB2 wires with Nb as the barrier layer should be lower than 750°C. Effects of amorphous carbon and TiC doped MgB2 wires were investigated by XRD, SEM and magnetization. The results show that substitution of B for C enhances the flux pinning but depresses Tc slightly. By controlling the processing parameters, an optimized Jc(H) performance is achieved under a partial amorphous C substitution. The Cu-clad 6-, 12-, and 36-filamentary MgB2 wires with Nb buffer layer also have been fabricated by the in-situ PIT method. To improve the strength of wires, the Nb-core was used as the central filament. The results show that the in-situ PIT technique can be used to produce the certain long length MgB2/Nb/Cu wires. The superconducting filaments of MgB2/Nb/Cu composite tubes have well workability suitable for the MgB2 wires long length and multi-filament.
100

Efeito do tratamento térmico nos fios ortodônticos de aço inoxidável

Kasbergen, Geraldo Francisco [UNESP] 27 November 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-11-27Bitstream added on 2014-06-13T18:32:11Z : No. of bitstreams: 1 kasbergen_gf_me_araca.pdf: 1206449 bytes, checksum: d032f277224382ffaa352a9929e1135b (MD5) / O objetivo deste trabalho foi avaliar o efeito do tratamento térmico (ou revenido) nos fios ortodônticos de aço inoxidável de Cromo Níquel (CrNi). Foram utilizados 40 arcos das espessuras 0.014”(0,35mm), 0.016”(0,40mm), 0.018”(0,45mm) e 0.020”(0,50mm). Os arcos foram divididos nos grupos sem e com tratamento térmico e, posteriormente, mensurados nas regiões anterior e posterior por meio do “software” AutoCad 2000 antes e após os ensaios mecânicos de compressão e tração por meio da máquina de ensaio universal EMIC. Os resultados foram submetidos à análise estatística com teste de multivariância ANOVA em nível de 5% (p<0,05). Diante da metodologia utilizada neste estudo, pode-se concluir que os arcos ortodônticos tratados termicamente apresentam suaves modificações transversais na região anterior e maiores aumentos transversais na região posterior, porém, provavelmente, sem relevância clínica. Os arcos sem e com tratamento térmico submetidos à força de compressão não apresentaram alterações transversais significantes nas regiões anterior e posterior. Nos arcos sem tratamento térmico submetidos à força de tração ocorreram aberturas mais acentuadas na região anterior nos arcos 0.020”. Na região posterior, a abertura proporcionada pela tração ocorreu com maior intensidade nos arcos sem tratamento térmico. Os arcos com tratamento térmico submetidos à força de tração não alteraram a distância transversal na região anterior. Nos arcos tratados termicamente constatou-se uma maior estabiidade, principalmente quando submetidos à tração ou à abertura. / The aim of this study was to evaluate the effect of heat treatment in orthodontic wires of Chrome Nickel (CrNi) stainless steel. 40 arches of 0.014 (0,35 mm), 0.016 (0.40 mm), 0.018 (0.45 mm) and 0.020 (0.50 mm) were used. The arches were divided 2 groups: with and without heat treatment and then measured in anterior and posterior regions using AutoCad 2000 software before and after tension and compression tests, using universal testing machine EMIC. The results were submitted to ANOVA multivariance test for statistical analysis with level of 5% (p<0.05). Through the methodology used in this study it can be concluded that the orthodontic arches with heat treatment presented soft transversal changes in the anterior region and larger transversal increases in the posterior region, probably without clinical relevance. The arches with and without heat treatment submited to compression force did not show significant transversal changes in the anterior and posterior regions. The arches 0.020 without heat treatment submited to traction force presented the largest increases in width in the anterior region. Traction force at posterior region led to arch openning with greater intensity in arches without heat treatment. The arches with heat treatment submited to traction force didn’t change the transversal distance in the anterior region. It was found that arches with heat treatment had greater stability, especially when submitted to traction or opening forces.

Page generated in 0.0364 seconds