• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 29
  • 24
  • 21
  • 10
  • 9
  • 6
  • 4
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 119
  • 76
  • 29
  • 27
  • 23
  • 11
  • 10
  • 9
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Untersuchungen zum Einsatz von frei modulierbaren gepulsten Nd:YAG-Laserstrahlquellen für das Schweissen von Refraktärmetallen /

Richter, Karsten. January 2006 (has links)
Zugl.: Aachen, Techn. Hochsch., Diss., 2006.
82

Einsatz von Laserverfahren zur Prozessierung von kristallinen Silizium-Solarzellen

Grohe, Andreas. January 2008 (has links)
Konstanz, Univ., Diss., 2008.
83

Laseroberflächenvorbehandlung zur Verbesserung der Adhäsion und Alterungsbeständigkeit von Aluminiumklebungen

Hose, Ralf January 2008 (has links)
Zugl.: Braunschweig, Techn. Univ., Diss., 2008
84

Experimentelle und theoretische Untersuchungen zur Frequenzkonversion von Nd:YAG-Laserstrahlung mit hoher Durchschnittsleistung

Mann, Guido. Unknown Date (has links) (PDF)
Techn. Universiẗat, Diss., 2003--Berlin.
85

Grundlegende Untersuchungen zum Laserstrahlbeschichten von Magnesiumlegierungen sowie zum artungleichen Laserstrahlschweißen mit Nd:YAG-Festkörperlaser und pulverförmigen Zusatzwerkstoffen

Kutschera, Ute. Unknown Date (has links) (PDF)
Techn. Universiẗat, Diss., 2003--Clausthal.
86

Simulation numérique du soudage du TA6V par laser YAG impulsionnel : caractérisation expérimentale et modélisation des aspects thermomécanique associées à ce procédé

Robert, Yannick 17 September 2007 (has links) (PDF)
Les procédés de soudage conduisent à des modifications de microstructure et induisent des contraintes et distorsions résiduelles jouant un rôle important sur la tenue mécanique des assemblages. Cette étude a pour objectif la modélisation des phénomènes thermomécaniques liés à l'opération de soudage du TA6V, ce qui implique d'identifier et de modéliser les sollicitations thermiques imposées par le soudage, le comportement métallurgique et thermomécanique du matériau. L'étude thermique et métallurgique a permis de montrer les principales évolutions de phases de l'alliage, durant le soudage laser. Ainsi, en première approximation, nous pouvons considérer que 3 phases distinctes sont à prendre en compte dans le calcul thermomécanique (la phase a, la phase ß et la phase a'). Afin de caractériser les phases ou mélange de phase en présence, des essais thermomécaniques sont réalisés pour diverses températures et conditions de déformation. Concernant le choix du modèle numérique, on adopte pour chacune des phases un modèle à variables internes de type Lemaître et Chaboche avec écrouissage cinématique non linéaire, un critère de plasticité de type Von Mises et une loi d'écoulement viscoplastique de type Norton, couplé à une loi de transition d'échelle. L'identification de chaque phase se fait par méthode inverse, à partir des essais thermomécaniques, grâce au module d'optimisation de ZSeT/ZMaT. La loi de localisation choisie est basée sur un modèle polycristallin en ß qui permet le passage du comportement microscopique de chaque phase au comportement macroscopique de l'ensemble. La validité de ce modèle décrit précédemment passera par la définition d'un essai expérimental représentatif des différents phénomènes rencontrés lors de l'opération de soudage.
87

Ocorrência de opacidade de cápsula posterior em cães pós-facoemulsificação, com ou sem a utilização de lente intraocular dobrável e efeitos do Nd: Yag Laser

Conceição, Luciano Fernandes da [UNESP] 15 July 2014 (has links) (PDF)
Made available in DSpace on 2015-04-09T12:28:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-07-15Bitstream added on 2015-04-09T12:48:22Z : No. of bitstreams: 1 000814977.pdf: 648645 bytes, checksum: 30e76402fd013eac04392612d142190b (MD5) / A catarata elenca-se entre as afecções oculares mais freqüentes em cães, sendo a facoemulsificação o método que melhor se adequa à sua terapia. As opacidades de cápsula posterior (OCPs) estão entre as complicações mais comuns e se manifestam em semanas ou meses após a facectomia. Lentes intraoculares (LIOs), empregadas na correção da hipermetropia pós-cirúrgica, são citadas como úteis na prevenção das OCPs, especialmente as acrílicas dobráveis, com bordas truncadas ou quadradas. Entretanto, quando OCPs se estabelecem requerem-se capsulotomias como forma de tratamento. Em pacientes humanos, reconhecem-se os efeitos do Nd:YAG laser como técnica não invasiva e segura frente a tais intercorrências. Para se compararem resultados de olhos de cães que receberam lentes intraoculares acrílicas dobráveis com olhos de cães afácicos, após facoemulsificação, durante um período de 180 dias, utilizaram-se 20 cães de raças diversas, machos ou fêmeas, que variaram de 3 a 7 anos de idade, apresentando catarata juvenil , imatura ou madura (imatura n = 10 , madura n = 10) bilateral. Dois grupos (G1 = com implante de lente intraocular e G2 = sem implante de lente artificial) foram formados aleatoriamente e todos os cães tiveram ambos os olhos operados. Após a cirurgia, os pacientes foram avaliados, semanalmente, quanto a presença ou a ausência de sinéquias, discoria, pressão intraocular, inflamação uveal e presença ou não de opacidade de cápsula posterior durante um período de 180 dias. Aos 60, 90, 120, 150 e 180 dias após a cirurgia, imagens da cápsula posterior foram capturados para avaliação da sua opacidade. Olhos com score 2 ou 3 de opacidade foram submetidos à terapia de capsulotomia pelo Nd:YAG laser. Variáveis categóricas ordinais foram comparadas (G1 X G2) empregando-se o teste de qui-quadrado e o teste exato de Fisher. Variáveis quantitativas foram comparadas empregando-se ANOVA com pós teste de Tukey / Cataracts are among the most common eye diseases in dogs, being the phacoemulsification method the one that best suits in their therapy. The posterior capsule opacification (PCOs) are among the most common complications and manifest themselves in weeks or months after cataract surgery. Intraocular lenses (IOLs) used in the correction of postoperative hyperopia, are mentioned as useful in the prevention of PCOs , especially the foldable acrylic ones with truncated or square edges. However, when PCOs are set up, capsulotomies are required as a treatment. In human patients, the effects of the Nd:YAG laser are recognized as a noninvasive and secure technique against such problems. To compare the results of eyes of dogs that received foldable acrylic intraocular lenses with eyes of aphakic dogs, after phacoemulsification, during a period of 180 days it was used 20 dogs of several breeds, male or female , ranging from 3 to 7 years old , with juvenile, immature or mature (n = 10 immature, mature n = 10) bilateral cataracts . Two groups (G1 = with implantation of intraocular lens and G2 = no artificial lens implant) were randomly formed and all dogs had both eyes operated. After the surgery, the patients were weekly evaluated for the presence or absence of synechiae, discoria, intraocular pressure, uveal inflammation and presence or absence of posterior capsule opacification during a period of 180 days. At 60, 90, 120, 150 and 180 days after surgery, the posterior capsule images were captured for evaluation of their opacity. Eyes with score 2 or 3 of opacity were underwent to capsulotomy by Nd:YAG laser. Ordinal categorical variables were compared (G1 X G2) using the chi-square and Fisher´s exact test. Quantitative variables were compared using ANOVA with Tukey post test. Synechiae were observed in the same frequency in both groups .G2 showed 30 % more discoria when compared to G1 Intraocular pressure did not differ between the groups. The ...
88

Ocorrência de opacidade de cápsula posterior em cães pós-facoemulsificação, com ou sem a utilização de lente intraocular dobrável e efeitos do Nd: Yag Laser /

Conceição, Luciano Fernandes da. January 2014 (has links)
Orientador: José Luiz Laus / Banca: Adriana Morales / Banca: João Antônio Tadeu Pigatto / Banca: Paola Castro Moraes / Banca: Luis Gustavo Gosuen Gonçalves Dias / Resumo: A catarata elenca-se entre as afecções oculares mais freqüentes em cães, sendo a facoemulsificação o método que melhor se adequa à sua terapia. As opacidades de cápsula posterior (OCPs) estão entre as complicações mais comuns e se manifestam em semanas ou meses após a facectomia. Lentes intraoculares (LIOs), empregadas na correção da hipermetropia pós-cirúrgica, são citadas como úteis na prevenção das OCPs, especialmente as acrílicas dobráveis, com bordas truncadas ou quadradas. Entretanto, quando OCPs se estabelecem requerem-se capsulotomias como forma de tratamento. Em pacientes humanos, reconhecem-se os efeitos do Nd:YAG laser como técnica não invasiva e segura frente a tais intercorrências. Para se compararem resultados de olhos de cães que receberam lentes intraoculares acrílicas dobráveis com olhos de cães afácicos, após facoemulsificação, durante um período de 180 dias, utilizaram-se 20 cães de raças diversas, machos ou fêmeas, que variaram de 3 a 7 anos de idade, apresentando catarata juvenil , imatura ou madura (imatura n = 10 , madura n = 10) bilateral. Dois grupos (G1 = com implante de lente intraocular e G2 = sem implante de lente artificial) foram formados aleatoriamente e todos os cães tiveram ambos os olhos operados. Após a cirurgia, os pacientes foram avaliados, semanalmente, quanto a presença ou a ausência de sinéquias, discoria, pressão intraocular, inflamação uveal e presença ou não de opacidade de cápsula posterior durante um período de 180 dias. Aos 60, 90, 120, 150 e 180 dias após a cirurgia, imagens da cápsula posterior foram capturados para avaliação da sua opacidade. Olhos com score 2 ou 3 de opacidade foram submetidos à terapia de capsulotomia pelo Nd:YAG laser. Variáveis categóricas ordinais foram comparadas (G1 X G2) empregando-se o teste de qui-quadrado e o teste exato de Fisher. Variáveis quantitativas foram comparadas empregando-se ANOVA com pós teste de Tukey / Abstract: Cataracts are among the most common eye diseases in dogs, being the phacoemulsification method the one that best suits in their therapy. The posterior capsule opacification (PCOs) are among the most common complications and manifest themselves in weeks or months after cataract surgery. Intraocular lenses (IOLs) used in the correction of postoperative hyperopia, are mentioned as useful in the prevention of PCOs , especially the foldable acrylic ones with truncated or square edges. However, when PCOs are set up, capsulotomies are required as a treatment. In human patients, the effects of the Nd:YAG laser are recognized as a noninvasive and secure technique against such problems. To compare the results of eyes of dogs that received foldable acrylic intraocular lenses with eyes of aphakic dogs, after phacoemulsification, during a period of 180 days it was used 20 dogs of several breeds, male or female , ranging from 3 to 7 years old , with juvenile, immature or mature (n = 10 immature, mature n = 10) bilateral cataracts . Two groups (G1 = with implantation of intraocular lens and G2 = no artificial lens implant) were randomly formed and all dogs had both eyes operated. After the surgery, the patients were weekly evaluated for the presence or absence of synechiae, discoria, intraocular pressure, uveal inflammation and presence or absence of posterior capsule opacification during a period of 180 days. At 60, 90, 120, 150 and 180 days after surgery, the posterior capsule images were captured for evaluation of their opacity. Eyes with score 2 or 3 of opacity were underwent to capsulotomy by Nd:YAG laser. Ordinal categorical variables were compared (G1 X G2) using the chi-square and Fisher's exact test. Quantitative variables were compared using ANOVA with Tukey post test. Synechiae were observed in the same frequency in both groups .G2 showed 30 % more discoria when compared to G1 Intraocular pressure did not differ between the groups. The ... / Doutor
89

Avaliação em microscopias óptica e eletrônica de varredura da adaptação de três cimentos endodônticos à dentina radicular submetida à ação prévia do Laser de Er: YAG, EDTA e solução salina fisiológica / Optical and scanning electron microscopic avaliations of three endodontic sealers adaptation to dentinal root submitted to the previous action of Er: YAG laser, EDTA and saline solution

Mônica Sampaio do Vale 09 March 2001 (has links)
A adaptação dos cimentos endodônticos, Ketac-Endo, AH Plus e Endomethásone, à dentina radicular submetida à ação prévia dos agentes de limpeza final laser de Er:YAG, EDTA a 17% e Solução Salina Fisiológica a 0,9% foi estudada pelas microscopias óptica e eletrônica de varredura. Foram empregados 90 caninos humanos extraídos, que após instrumentação pela técnica escalonada de memória e irrigação com hipoclorito de sódio a 1%, foram divididos em três grupos de 30, de acordo com o agente de limpeza final empregado. No grupo A, empregou-se o laser de Er:YAG intracanal, com parâmetros de 100mJ (energia real de 44mJ), 10pps, durante dez segundos, sob refrigeração a ar, com movimentos circulares no sentido apicocoronário, seguido de irrigação com 20ml de solução salina fisiológica a 0,9%. No grupo B, empregaram-se 5ml de EDTA a 17% durante cinco minutos, seguido de irrigação com solução salina fisiolólgica a 0,9%. No grupo C, empregaram-se 20ml de Solução Salina Fisiológica a 0,9%. Após secagem, os canais radiculares foram armazenados em solução salina fisiológica a 0,9% durante 48 horas. Cada grupo foi então dividido em três subgrupos de dez,de acordo com o cimento endodôntico. Os 90 canais radiculares foram obturados pela técnica clássica, seguida da condensação lateral ativa da guta-percha. Após comprovação radiográfica da obturação os canais foram vedados com Cimpat no terço cervical e forame apical, e as raízes armazenadas em solução salina fisiológica a 0,9% em umidade de 100% a 37oC, durante 30 dias. Em seguida, foram seccionadas transversalmente a 5mm do ápice radicular, fotografadas com aumento de quatro vezes e submetidas à análise em microscopia óptica. Para a análise em microscopia eletrônica de varredura, as secções apicais foram moldadas em silicona Aquasil e os moldes obtidos foram metalizados e fotografados em aumentos que variaram de 50 a 200 vezes. As fotos obtidas pelas microscopias foram escaneadas e transferidas para um programa de medida de área (SigmaScan) para mensuração das áreas preenchidas pelos materiais obturadores e das possíveis fendas entre material obturador e parede do canal radicular. Diante dos resultados obtidos com a metodologia empregada e da discussão apresentada pudemos concluir que: 1- Os agentes de limpeza final empregados exerceram efeito diferenciado na adaptação dos cimentos testados. O laser de Er:YAG interferiu na adaptação de todos os cimentos, o EDTA melhorou a adaptação do Endomethásone e do AH Plus em relação ao laser de Er:YAG e à solução salina fisiológica a 0,9% e a solução salina fisiológica melhorou a adaptação do Ketac-Endo, em ambas microscopias empregadas. 2- O Endomethásone apresentou a pior adaptação entre os cimentos e o AH Plus apresentou a melhor adaptação com EDTA na microscopia eletrônica de varredura. 3- A associação das microscopias óptica e eletrônica de varredura mostrou ser um método confiável na detecção das fendas, sendo que a microscopia eletrônica de varredura propiciou melhor visualização. 4- Todos os cimentos testados apresentaram alteração dimensional, verificando-se contração para o Ketac-Endo, expansão para o Endomethásone e AH-Plus, sendo que o AH Plus mostrou-se mais próximo da estabilidade dimensional. / The adaptation of endodontic sealers, Ketac-Endo, AH Plus and Endomethásone to dentinal root submitted to the previous action of final Er:YAG laser cleaning agents, EDTA at 17% and a saline solution at 0.9% was studied by Optical and Scanning Electron Microscopy. Ninety extracted human canines were employed, and following the step back technique preparation and irrigation with sodium hypochlorite solution they were divided into three groups with thirty teeth each, according to the final cleaning agent used. In group A, Er:YAG laser was used intracanal, with the following parameters: 100mJ (real energy 44mJ), 10pps, for 10 seconds under air cooling with circular movements in apicocervical direction and the canals were irrigated with 20ml saline solution at 0.9%. In group B, 5ml of EDTA at 17% irrigated the root canals for 5 minutes, followed by a saline solution at 0.9%. In group C, a saline solution at 0.9% was employed to irrigate the root canals. After drying, the roots were stored in a saline solution at 0.9% for 48 hours. Each group was divided into three subgroups of ten, according to the selected endodontic sealer. The ninety root canals were filled through standard technique, followed by gutta-percha lateral condensation. Following radiographic filling proof, the root canals were sealed with Cimpat in the cervical third and at the apical foramen, and the roots stored in a 0.9% saline solution at 37oC and 100% humidity for 30 days. Afterwards, they were transversally secctioned at 5mm to the root apex, and photographed with a 4x magnification, and submitted to optical microscopic analysis. Before the Scanning Electron Microscopic analysis, the apical root sections were molded with Aquasil and the obtained replicas metallized and photographed with 50x and 200x magnifications. The resulting images, in both microscopies, were scanned and transferred to the area measurement software program (SigmaScan) to measure the areas filled by endodontic materials and the failed areas between the endodontic material and the root canal walls. Through the results with the selected methodology and by means of the presented discussion, we could conclude that: 1- The final cleaning agents employed in the root canals presented different effects in the adaptation of the endodontic sealers. The Er:YAG laser was harmful to the adaptation of all the endodontic sealers; the EDTA improved the adaptation of Endomethásone and AH Plus and the 0.9% saline solution improved the adaptation of Ketac-Endo in both microscopies. 2- Endomethásone presented the worst adaptation compared to the other sealers and AH Plus presented the best adaptation with EDTA by Scanning Electron Microscopic analysis. 3- The Optical Microscopy associated with the Scanning Electron Microscopy proved to be a safe method in detecting filling failures, being, the Scanning Electron Microscopy the best. 4- All endodontic sealers presented dimensional alterations, Ketac-Endo presented contraction, Endomethásone and AH Plus presented expansion, being, AH Plus closer to dimensional stability.
90

Processo de deposição e propriedades de filmes de dióxido de titânio obtidos por "laser ablation"

Damião, Alvaro Jose 13 August 2002 (has links)
Orientador: Mario Antonio Bica de Moraes / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-02T03:15:36Z (GMT). No. of bitstreams: 1 Damiao_AlvaroJose_D.pdf: 7111682 bytes, checksum: a021d57bfd78393326cd15212c4cae6d (MD5) Previous issue date: 2002 / Resumo: Este trabalho descreve os estudos do processo de deposição a laser de TiO2, assim como algumas propriedades dos alvos utilizados e dos filmes depositados. O objetivo era a obtenção de filmes para serem utilizados como elemento de composição em componentes ópticos de precisão. Foram utilizados três diferentes lasers pulsados: CO2, Nd:YAG e Vapor de Cobre, oscilando nos comprimentos de onda tradicionais, ou seja, sem dobrar freqüências de emissão. A taxa de repetição dos lasers variou de 1 Hz para o laser de CO2 até 18 kHz para o laser de vapor de co-bre. Os lasers e a câmara de evaporação foram desenvolvidos no Instituto de Estudos Avançados IEAv - CTA, onde os trabalhos de deposição foram realizados. A espessura dos filmes depositados foi obtida por três processos diferentes: balança, osci-lador/cristal de quartzo e interferometria, a fim de verificar se havia influência do processo de de-posição no comportamento do cristal de quartzo. Como não houve influência, foram obtidos então os resultados de taxa de deposição, como função do tempo para diferentes condições de deposi-ção. Os alvos foram tratados termicamente, para verificar a influência do material de partida, não tendo sido observadas diferenças nos filmes obtidos. Os filmes foram caracterizados por téc-nicas ópticas (Método do Envelope), difração de raios X, XPS e microscopia eletrônica de varre-dura. Foram obtidos filmes uniformes, aparentemente sem os defeitos normalmente causados pela deposição a laser. Os filmes, como depositados, apresentaram alguma absorção, o que invia-biliza a sua utilização sem tratamento térmico / Abstract: This work presents the results of a laser deposition process of TiO2, target and thin film properties. The aim was to obtain thin films to be part of a multilayer coating for precision optical components. Three different pulsed lasers were used to deposit the films: CO2, Nd:YAG and Copper Vapor Lasers, LVC, all of them oscillating in their natural modes, i.e., without any apparatus to double the emission frequency. The repetition rate of the laser was as low as 1 Hz for CO2 and as high as 18kHz for LVC. The evaporation chamber and the lasers were developed at the Instituto de Estudos Avançados, IEAv-CTA, where the films were deposited. Mass measurement, quartz crystal oscillator and interferometry evaluated the films thick-ness, to check if the deposition process could affect the results obtained by the crystal oscillator. As no influence was detected, the crystal oscillator was used to measure the deposition rate of the films, as function of time, for different deposition conditions. The targets received a thermal treatment, to verify the influence of starting materials on the obtained films. The films were analyzed by Envelop Method (optical properties), X-ray, XPS and SEM. Uniform films were obtained, without the defects normally found when using laser deposi-tion. Films deposited at room temperature (as deposited) presented some absorption, which obliges the use of thermal treatment / Doutorado / Física / Doutor em Ciências

Page generated in 0.0266 seconds