• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 29
  • 24
  • 21
  • 10
  • 9
  • 6
  • 4
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 119
  • 76
  • 29
  • 27
  • 23
  • 11
  • 10
  • 9
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Diagnostik an laserinduzierten Plasmakanälen und Mikropinchstrukturen mittels Kurzzeitinterferometrie und zeitaufgelöster Röntgenspektroskopie

Blaudeck, Thomas 17 December 2002 (has links)
This work deals with the interaction of intense 100 ps laser pulses with double-layer foil targets, consisting of one dielectric (Mylar) layer and one metallic layer. The diagnostics of the evolving plasmas is done by the means of shorttime interferometry, time-resolved X-ray spectroscopy, and methods of ion dosimetry in polymer nuclear track detectors (CR-39). / Die Arbeit beschäftigt sich mit der Wechselwirkung intensiver 100-ps-Laserpulse eines Nd:YAG-Lasersystems mit Zweischicht-Folientargets, die aus einer dielektrischen Schicht (Mylar) und einer metallischen Schicht bestehen. Die entstehenden Plasmen werden mittels Kurzzeitinterferometrie und zeitaufgelöster Röntgenspektroskopie sowie mit Methoden der Ionendosimetrie in Polymer-Kernspurätzdetektoren (CR-39) untersucht.
112

不均一系微小粒子の生物活性測定システムの開発

吉岡, 崇仁, 和田, 英太郎, 林, 秀剛 03 1900 (has links)
科学研究費補助金 研究種目:基盤研究(B) 課題番号:06554036 研究代表者:吉岡 崇仁 研究期間:1994-1996年度
113

Improvement of a fluorescence immunoassay with a compact diode-pumped solid state laser at 315 nm

Niederkrüger, Matthias, Salb, Christian, Beck, Michael, Hildebrandt, Niko, Löhmannsröben, Hans-Gerd, Marowsky, Gerd January 2006 (has links)
We demonstrate the improvement of fluorescence immunoassay (FIA) diagnostics in deploying a newly developed compact diode-pumped solid state (DPSS) laser with emission at 315 nm. The laser is based on the quasi-three-level transition in Nd:YAG at 946 nm. The pulsed operation is either realized by an active Q-switch using an electro-optical device or by introduction of a Cr<SUP>4+</SUP>:YAG saturable absorber as passive Q-switch element. By extra-cavity second harmonic generation in different nonlinear crystal media we obtained blue light at 473 nm. Subsequent mixing of the fundamental and the second harmonic in a β-barium-borate crystal provided pulsed emission at 315 nm with up to 20 μJ maximum pulse energy and 17 ns pulse duration. Substitution of a nitrogen laser in a FIA diagnostics system by the DPSS laser succeeded in considerable improvement of the detection limit. Despite significantly lower pulse energies (7 μJ DPSS laser versus 150 μJ nitrogen laser), in preliminary investigations the limit of detection was reduced by a factor of three for a typical FIA.
114

Etude et réalisation de lasers solides a modes couples (yag dope néodyme et saphir dope tiane). Compression d'impulsions.

Lépine, Thierry 17 January 1991 (has links) (PDF)
Ce mémoire présente différentes techniques permettant de produire des impulsions lumineuses très brèves. Dans un premier temps, nous avons conçu et réalisé un laser nd:yag continu a modes couples activement et double en fréquence. Ce laser délivre des impulsions dont la largeur a mi-hauteur en intensité est voisine de 60 picosecondes a 532 nanomètres, repetitives a 82 mhz. La puissance moyenne des impulsions est suffisante pour permettre le pompage d'un laser a colorant en mode synchrone. Ce dernier délivre des impulsions lumineuses dont la durée est voisine de 10 picosecondes et répétitives a 82 mhz. L'ensemble du système a été caractérise en utilisant des caméras a balayage de fente en mode sinusoïdal ou en mode monocoup. Nous avons ensuite étudié la possibilité de produire des impulsions femtosecondes (10##1#5 s) en comprimant les impulsions délivrées par un laser a colorant a deux jets (milieu amplificateur rh6g), absorbant saturable (dodci). Avant compression, ces impulsions ont une largeur a mi-hauteur en intensité voisine de une picoseconde et sont répétitives a environ 80 mhz. Nous avons pu comprimer ces impulsions jusqu'a des durees voisines de 130 femtosecondes. Les résultats expérimentaux sont très proches des prévisions théoriques. Enfin, nous avons produit directement des impulsions lumineuses femtosecondes a partir d'une cavité laser dont le milieu amplificateur est un cristal de saphir dope au titane (ti:al#2o#3). Dans un premier temps, le couplage des modes est réalisé a l'aide d'un modulateur acousto-optique. Dans cette configuration, le laser produit des impulsions dont la durée est aussi courte que 10 picosecondes, répétitives a 125 mhz et dont le domaine d'accord en longueur d'onde est limite par les miroirs entre 72 et 800 nanomètres. Dans un second temps, le couplage des modes est réalisé en utilisant un absorbant saturable (hitci) et la dispersion intracavite est aju.
115

Improving the Success of Melanocyte Keratinocyte Transplantation Surgery in Vitiligo; The Role of JAK Inhibitors, and Ablative Laser Resurfacing

Ahmed Refat, Maggi 17 June 2021 (has links)
The Melanocyte Keratinocyte Transplantation Procedure (MKTP) is an effective surgical replacement of lost melanocytes in recalcitrant vitiligo and pigmentary skin disorders. However, it is only effective in stable vitiligo lesions because active autoimmunity destroys the newly transplanted melanocytes. Despite careful selection of candidates based on the reported clinical stability, the success of the procedure is still unpredictable. MKTP candidates with non-segmental, segmental, and mixed vitiligo, as well as hypopigmented scars and Piebaldism patients were enrolled to our studies. Our aim was first, to investigate the possible immunological mechanisms responsible for the unpredictable post- transplantation outcomes, including T cell subsets and inflammatory chemokines, by correlating these biomarkers with clinical phenotypes, duration of stability, and surgical outcomes. We used suction blister biopsy, a minimally invasive technique that we developed to sample human skin. Moreover, we quantified transplanted melanocytes in the suspension using flow cytometry. Following MKTP, we corelated these biomarkers to the repigmentation score. We found that CD8+ T cells remain in some clinically stable vitiligo lesions, correlate negatively with the post-surgical score of repigmentation, and inversely impact the durability of the responses. Interestingly, the number of transplanted melanocytes in the suspension and the duration of stability do not have prognostic roles. Based on our findings and in a second group of patients, we suppressed the activity of T cells to enhance the outcomes of MKTP. We used Ruxolitinib, JAK1/2 inhibitor, in a triple blinded randomized controlled within subject study, in comparison with Tacrolimus (a calcineurin inhibitor and the standard of care treatment in vitiligo) as well as placebo control. We found lower T cell infiltrate, lower chemokines, and better skin repigmentation in lesions treated with MKTP plus Ruxolitinib or Tacrolimus than in lesions treated with MKTP plus placebo. Lastly, we compared two different types of laser in preparation of the recipient skin for MKTP - ablative versus fractional Er:YAG laser. We found that the ablative laser is combined with minimal CD8+ T cell epidermal infiltrate and superior repigmentation score in comparison to more infiltrate and lower repigmentation score with the fractional laser. Taken together, these results from our studies provide novel insight to predict the optimal surgical candidates and will improve surgical outcomes. It advances the treatment of vitiligo by uncovering the impact of autoimmunity on the success of repigmentation and discovering new approaches to optimize the surgical treatment options in patients with vitiligo and pigmentary skin disorders.
116

Laserinduzierte Prozesse im System C2H2+ + H2

Lescop, Emmanuelle 18 August 2000 (has links) (PDF)
In der vorliegenden Arbeit wird bei tiefen Temperaturen die bimolekulare Reaktion C2H2+ + H2 -- C2H3+ + H in einem HF 22-Pol-Ionenspeicher untersucht. %weist eine Aktivierungsenergie von ca. 50 meV auf. Dreikörper- und Strahlungsratenkoeffizienten der Assoziationsreaktion C2H2+ + H2 -- C2H4+ werden bestimmt, sowie ihre Temperaturabhängigkeit. Durch Anregung der infrarot-aktiven antisymmetrischen C--H-Streckschwingung nu3 des C2H2+-Ions wird die Aktivierungsenergie der bimolekularen Reaktion überwunden. Zunächst wird ein Nd:YAG-Laser gepumpter Farbstofflaser mit Differenzfrequenzmischung und dann ein schmalbandiger cw-betriebener Bleisalzdiodenlaser zur Induzierung der Reaktion eingesetzt. Der Nachweis des Produkts C2H3+ dient als Hinweis auf den Anregungszustand der C2H2+-Ionen ( chemical probing) und somit lassen sich die P-, Q- und R-Zweige der Normalschwingung nu3 von C2H2+ aufzeichnen. Die empfindliche untergrundfreie Spektroskopie der Prim¨arionen wird demonstriert. Die hohe spektrale Auflösung des Experiments ermöglicht die Schwingungs-, Rotations-, Feinstruktur- und Kernspinszustandspezifische Anregung der C2H2+-Ionen. %Die Ergebnisse der vorliegenden Arbeit zeigen Rotationseffekte. Es wird gezeigt, dass eine grössere Rotationsquantenzahl des C2H2+-Ions zur Behinderung der Reaktion führt. Mit der Messung der C2H3+-Ionenzahl als Funktion der Speicherzeit und der H2-Dichte werden die Ratenkoeffizienten der laserinduzierten Reaktion und der Reaktion schwingungsangeregter Primärionen bestimmt. Es wird vermutet, dass die Energie nicht unmittelbar in der Reaktionskoordinate vorhanden ist, sondern einen Sto¨skomplex \mbox{\glqq erhitzt\grqq}. Die von einer Barriere im Eingangskanal behinderte Komplexbildung kann die vorgestellten Ergebnisse erklären. Der Ratenkoeffizient der stossinduzierten Schwingungsrelaxation wird ermittelt. Die experimentelle Bestimmung des Einstein-Koeffizienten der spontanen Emission ermöglicht es, die Lebensdauer des angeregten Zustandes sowie das Dipolmatrixelement und die Schwingungsintensität von nu3 abzuschätzen.
117

高輝度・高解像度電子顕微鏡観察YAGスクリ-ンに関する基礎研究

日比野, 倫夫, 丹司, 敬義, 花井, 孝明, 田中, 成泰, 木村, 啓子 03 1900 (has links)
科学研究費補助金 研究種目:基盤研究(B)(2) 課題番号:07455036 研究代表者:日比野 倫夫 研究期間:1995-1996年度
118

Laserinduzierte Prozesse im System C2H2+ + H2

Lescop, Emmanuelle 15 August 2000 (has links)
In der vorliegenden Arbeit wird bei tiefen Temperaturen die bimolekulare Reaktion C2H2+ + H2 -- C2H3+ + H in einem HF 22-Pol-Ionenspeicher untersucht. %weist eine Aktivierungsenergie von ca. 50 meV auf. Dreikörper- und Strahlungsratenkoeffizienten der Assoziationsreaktion C2H2+ + H2 -- C2H4+ werden bestimmt, sowie ihre Temperaturabhängigkeit. Durch Anregung der infrarot-aktiven antisymmetrischen C--H-Streckschwingung nu3 des C2H2+-Ions wird die Aktivierungsenergie der bimolekularen Reaktion überwunden. Zunächst wird ein Nd:YAG-Laser gepumpter Farbstofflaser mit Differenzfrequenzmischung und dann ein schmalbandiger cw-betriebener Bleisalzdiodenlaser zur Induzierung der Reaktion eingesetzt. Der Nachweis des Produkts C2H3+ dient als Hinweis auf den Anregungszustand der C2H2+-Ionen ( chemical probing) und somit lassen sich die P-, Q- und R-Zweige der Normalschwingung nu3 von C2H2+ aufzeichnen. Die empfindliche untergrundfreie Spektroskopie der Prim¨arionen wird demonstriert. Die hohe spektrale Auflösung des Experiments ermöglicht die Schwingungs-, Rotations-, Feinstruktur- und Kernspinszustandspezifische Anregung der C2H2+-Ionen. %Die Ergebnisse der vorliegenden Arbeit zeigen Rotationseffekte. Es wird gezeigt, dass eine grössere Rotationsquantenzahl des C2H2+-Ions zur Behinderung der Reaktion führt. Mit der Messung der C2H3+-Ionenzahl als Funktion der Speicherzeit und der H2-Dichte werden die Ratenkoeffizienten der laserinduzierten Reaktion und der Reaktion schwingungsangeregter Primärionen bestimmt. Es wird vermutet, dass die Energie nicht unmittelbar in der Reaktionskoordinate vorhanden ist, sondern einen Sto¨skomplex \mbox{\glqq erhitzt\grqq}. Die von einer Barriere im Eingangskanal behinderte Komplexbildung kann die vorgestellten Ergebnisse erklären. Der Ratenkoeffizient der stossinduzierten Schwingungsrelaxation wird ermittelt. Die experimentelle Bestimmung des Einstein-Koeffizienten der spontanen Emission ermöglicht es, die Lebensdauer des angeregten Zustandes sowie das Dipolmatrixelement und die Schwingungsintensität von nu3 abzuschätzen.
119

試料損傷のない高解像度電子顕微鏡観察法の研究

日比野, 倫夫, 丸勢, 進, 下山, 宏, 杉山, せつ子, 花井, 孝明, 内川, 嘉樹 03 1900 (has links)
科学研究費補助金 研究種目:一般研究(A) 課題番号:62420021 研究代表者:日比野 倫夫 研究期間:1987-1989年度

Page generated in 0.0156 seconds