• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 595
  • 210
  • 136
  • 54
  • 52
  • 41
  • 20
  • 19
  • 16
  • 16
  • 8
  • 7
  • 6
  • 6
  • 5
  • Tagged with
  • 1457
  • 135
  • 129
  • 106
  • 102
  • 99
  • 95
  • 82
  • 81
  • 79
  • 76
  • 71
  • 70
  • 70
  • 69
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Controle de qualidade de produtos cartográficos : uma proposta metodológica /

Nogueira Júnior, João Bosco. January 2003 (has links)
Resumo: O controle de qualidade (CQ) de dados cartográficos é uma atividade de extrema importância dentro das Ciências Cartográficas. Envolve, em geral, a análise de 7 elementos, dentre eles a qualidade posicional do produto cartográfico. No Brasil, a análise da qualidade posicional é baseada no PEC (Padrão de Exatidão Cartográfica), contida no Decreto Lei 89.817 de 20/06/1984, o qual foi concebido quando se tinha disponível apenas tecnologia para gerar produtos analógicos. A realidade hoje é outra, já que a cartografia digital tem praticamente substituído a analógica. Os objetivos principais deste trabalho são os seguintes: investigar os problemas relacionados ao controle de qualidade tendo em vista a cartografia digital, incluindo o Decreto Lei 89.817; apresentar um estudo detalhado sobre amostragem, visando identificar o número de pontos necessários no controle de qualidade posicional baseado em fundamentos científicos. A metodologia proposta consiste em aplicar estudos sobre amostragem e testes estatísticos de análise de tendência e precisão a dados disponíveis e com isso determinar procedimentos e rotinas ideais para avaliar, não só a qualidade posicional, mas também da linhagem, fidelidade de atributos, completeza, consistência lógica, fidelidade à semântica e temporalidade. / Abstract: The quality control (CQ) of cartographic data is an activity of great value in the field of Cartographic Sciences. It involves, generally, the analysis of 7 elements, among them the positional quality of the cartographic product. In Brazil, it is based in Brazilian Cartographic Accuracy Standard contained in the Decree Law 89.817 of 06/20/1984, conceived in the moment that only analogical products were available. Nowadays, the reality is different, because the digital cartography has been substituting the analogical one. The main objectives of this work are the following ones: (a) to investigate the problems related for digital cartography's quality control, including the Decree 89.817; (b) to present a detailed study on sampling, concerning to identify the amount points of necessary in the quality control based on scientific foundations. The proposed methodology consists in applying studies on sampling, statistical tests tendency and precision analysis for available data and, thereafter, to determine procedures and suitable routines for evaluating not only the positional quality but also lineage, atttribute accuracy, completeness, logical consistency, semantic accuracy and temporal information. / Orientador: João Francisco Galera Monico / Coorientador: Vilma Mayumi Tachibana / Banca: Leonardo Castro de Oliveira / Banca: Paulo de Oliveira Camargo / Mestre
192

Acurácia do estridor para o diagnóstico de estenose subglótica por intubação em pacientes pediátricos

Enéas, Larissa Valency January 2013 (has links)
Objetivos: Determinar a acurácia do estridor em predizer a ocorrência de estenose subglótica (ESG) por intubação em pacientes pediátricos quando comparado ao seu diagnóstico por endoscopia de via aérea. Delineamento: Coorte Prospectiva. Métodos: Foram elegíveis todas as crianças de 28 dias a quatro anos de idade internadas na Unidade de Terapia Intensiva Pediátrica do Hospital de Clínicas de Porto Alegre que necessitaram de intubação endotraqueal por mais de 24 horas. Foram excluídas as com história de intubação, doença laríngea prévia, presença de traqueostomia atual ou no passado, presença de malformações craniofaciais e aquelas consideradas portadoras de doença terminal. Foram acompanhadas diariamente e, após a extubação, submetidas à fibronasolaringoscopia (FNL). Novo exame era realizado em sete a dez dias naquelas com alterações moderadas a graves no primeiro. Se essas persistissem ou surgissem sintomas, independentemente da FNL inicial, realizava-se laringoscopia sob anestesia geral. Após a extubação, verificou-se diariamente a ocorrência de estridor, classificado como presente ou ausente. Resultados: Foram acompanhados, de novembro de 2005 a agosto de 2012, 194 pacientes. A incidência de estridor pós-extubação foi de 43,81%. O estridor apresentou uma sensibilidade de 77,78% (IC 95%: 51,9 – 92,6) e especificidade de 59,66% (IC 95%: 52,0 – 66,9) em detectar ESG nessa amostra, o valor preditivo positivo (VPP) foi de 16,47% (IC 95%: 9,6 – 26,4) e o valor preditivo negativo (VPN) foi de 96,33% (IC 95%: 90,3 – 98,8). O estridor quando presente por mais de 72 horas ou quando esse surgiu após as primeiras 72 horas da extubação apresentou uma sensibilidade de 66,67% (IC 95%: 41,2 – 85,6) e especificidade de 88,5% (IC 95%: 83,1 – 93,1). O VPP foi de 38,8% (IC 95%: 22,4 – 57,7) e o VPN foi de 96,23 (IC 95%: 91,6 – 98,5). A área da curva ROC foi 0,78 (IC 95%: 0,65 – 0,91). Conclusões: A ausência de estridor mostrou-se adequada para afastar o diagnóstico de ESG por intubação em pacientes pediátricos após o período neonatal. Melhor especificidade foi encontrada quando o estridor ocorreu por mais de 72 horas após a extubação ou quando teve o início depois desse período. A partir desse estudo, parece adequado indicar endoscopia de via aérea, para a confirmação de ESG, apenas naqueles pacientes que apresentarem estridor após 72 horas da extubação. / Objective: To determine the accuracy of stridor in predicting the occurrence of postintubation subglottic stenosis (SGS) in pediatric patients when compared with endoscopy airway diagnosis. Design: Prospective cohort. Methods: Children aged 28 days to four years admitted to the Pediatric Intensive Care Unit of Hospital de Clinicas de Porto Alegre who required endotracheal intubation for more than 24 hours were eligible for study. Patients with previous intubation, history of laryngeal disease, current or past tracheostomy, presence of craniofacial malformations and those considered terminal by the staff were excluded from the study. Children were monitored daily and underwent flexible fiberoptic laryngoscopy (FFL) after extubation. Those who presented moderate to severe abnormalities in this first examination underwent another FFL between 7 and 10 days later. If these lesions persisted or symptoms developed, regardless of the findings in initial examination, laryngoscopy under general anesthesia was warranted. Occurrence of stridor was verified daily after extubation and classified as either present or absent. Results: We followed 194 children between November 2005 and August 2012. The incidence of post-extubation stridor was 43.81 per cent. Stridor had a sensitivity of 77.78% (CI 95%: 51.9 – 92.6) and specificity of 59.66% (CI 95%: 52.0 – 66.9) to detect SGS in this sample. The positive predictive value (PPV) was 16.47% (CI 95%: 9.6 – 26.4) and the negative predictive value was 96.33% (CI 95%: 90.3 – 98.8). Stridor, when present more than 72 hours or when started after these first 72 hours after extubation, showed a sensitivity of 66.67% (CI 95%: 41.2 – 85.6), specificity of 88.5% (CI 95%: 83.1 – 93.1), PPV of 38.8% (CI 95%: 22.4 – 57.7) and NPV of 96.23% (CI 95%: 91,6 – 98,5). ROC curve area was 0,78 (CI 95%: 0.65 – 0.91). Conclusions: Absence of stridor proved to be adequate to rule out the diagnosis of post-intubation SGS in pediatric patients. Improved specificity was found when stridor occurred for more than 72 hours after extubation or when started after that. From this study, it seems appropriate to indicate airway endoscopy under general anesthesia for the confirmation of SGS only in those patients who present stridor after 72 hours following extubation.
193

Previsão de demanda no setor de suplementação animal usando combinação e ajuste de previsões

Silva, Rodolfo Benedito da January 2014 (has links)
A previsão de demanda desempenha um papel de fundamental importância dentro das organizações, pois através dela é possível obter uma declaração antecipada do volume demandado no futuro, permitindo aos gestores a tomarem decisões mais consistentes e alocarem os recursos de modo eficaz para atender esta demanda. Entretanto, a eficiência na tomada de decisões e alocação dos recursos requer previsões cada vez mais acuradas. Diante deste contexto, a combinação de previsões tem sido amplamente utilizada com o intuito de melhorar a acurácia e, consequentemente, a precisão das previsões. Este estudo tem por objetivo fazer a adaptação de um modelo de previsão para estimar a demanda de produtos destinados à suplementação animal através da combinação de previsões, considerando as variáveis que possam impactar na demanda e a opinião de especialistas. O trabalho está estruturado em dois artigos, sendo que no primeiro buscou-se priorizar e selecionar, através do Processo Hierárquico Analítico (AHP), variáveis que possam impactar na demanda para que estas pudessem ser avaliadas na modelagem via regressão do artigo 2. Por sua vez, no segundo artigo, realizou-se a adaptação do modelo composto de previsão idealizado por Werner (2004), buscando uma previsão final mais acurada. Os resultados obtidos reforçam que as previsões, quando combinadas, apresentam desempenhos superiores para as medidas de acurácia MAPE, MAE e MSE, em relação às previsões individuais. / The demand prediction has a role of fundamental importance inside the organizations, because trough it is possible to obtain a previous declaration of the demanded amount in the future, allowing the managers to take more consistent decisions and to allocate the resources in an efficient manner in order to satisfy this demand. However, the efficiency in the support decision and resource allocation demands accurated predictions. So, the combination of predictions have been used with the aim of improving the accuracy and, consequently, the precision of the prediction. This study has as objective to do an adaptation of a prediction model to estimate the demand of products designated to animal supplementation through the combination of prediction, considering the variables that can impact in the demand and in the expert opinion. The work is structured in two papers, considering that the first searches to priorize and select through the Analitic Hierarch Process (AHP), variables that can impact in the demand, so they could be evalute in the regression modelling of the paper 2. By the way, in the second paper, it was done an adaptation of the composed prediction model proposed by Werner (2004), searching for a more accurated final prediction. The obtained results reinforce that the prediction, when combined, present superior performance to the accuracy metrics MAPE, MAE and MSE, in relation to the individual predictions.
194

Previsão de demanda turística e a acurácia das previsões frente à realização de megaeventos

Bündchen, Cristiane January 2016 (has links)
O turismo entrou em um período de forte expansão após a Segunda Guerra Mundial que perdura até os dias atuais. O aumento da circulação de turistas repercute na geração de renda e empregos para os países visitados, além do enriquecimento adquirido através das trocas culturais. Este crescimento tem despertado o interesse da comunidade científica, bem como profissional, com o intuito de explorar as metodologias para a modelagem e previsão da demanda turística. Estimativas acuradas da demanda servem de apoio para corretas tomadas de decisão por parte dos gestores quanto ao dimensionamento adequado de recursos financeiros, especialmente frente à realização de um evento de grandes proporções. Neste sentido, este trabalho tem por objetivos verificar quais são as técnicas atualmente mais utilizadas para previsão de demandas turísticas através de revisão da literatura, desde 2005 até 2015; utilizar dois métodos de modelagem (ARIMA e RNA) para modelar e prever a demanda turística de duas sedes olímpicas recentes; comparar essas previsões com as previsões obtidas por cinco métodos de combinação de previsões (médias aritmética, harmônica e geométrica, variância mínima e regressão linear) e; aplicar o método mais acurado para prever a demanda turística do Brasil. Os resultados foram avaliados através de três medidas de acurácia. Em virtude da realização dos Jogos Olímpicos em 2016, a demanda brasileira para este período foi modelada e prevista e a previsão foi ajustada segundo um ajuste matemático sazonal, objetivando ganho de acurácia. Foi observado ganho de acurácia quando as previsões foram combinadas e, na série brasileira, o ajuste adotado indicou um acréscimo de 175% na demanda original para agosto de 2016. / Tourism has experienced a strong increase since the end of World War II. The increase in tourist circulation results in income and employment expansion, besides the cultural enrichment involved in such experiences. This growth has attracted attention from the scientific community as well as professional, with the objective of exploring the methodologies for tourism demand modelling and forecasts. Accurate demand estimates serve as support for correct decision making by managers especially considering financial resource scaling for major events. In this sense, this study aims to verify which techniques are more currently used for forecasting tourism demand through review of the literature from 2005 to 2015; using two modeling methods (ARIMA and ANN) to make models and forecasting the tourism demand of two recent Olympic hosts; comparing these forecasts with the forecasts obtained for five methods of combining forecasts (arithmetic, harmonic and geometric means, minimum variance and linear regression) and; applying the most accurated method to forecast the tourism demand in Brazil. The results were evaluated using three different accuracy measurements. By virtue of the 2016 Olympic Games, the Brazilian tourism demand was modeled and the forecast was adjusted by a seasonal mathematical adjustment, designed for better precision. A gain in preciseness was observed when forecasts were combined and, for the Brazilian series, the adopted adjustment indicated an increase of 175% when compared with the original demand for August 2016.
195

The Relationship of Club Handle Twist Velocity to Selected Biomechanical Characteristics of the Golf Drive

January 2014 (has links)
abstract: During the downswing all golfers must roll their forearms and twist the club handle in order to square the club face into impact. Anecdotally some instructors say that rapidly twisting the handle and quickly closing the club face is the best technique while others disagree and suggest the opposite. World class golfers have swings with a range of club handle twist velocities (HTV) from very slow to very fast and either method appears to create a successful swing. The purpose of this research was to discover the relationship between HTV at impact and selected body and club biomechanical characteristics during a driver swing. Three-dimensional motion analysis methods were used to capture the swings of 94 tour professionals. Pearson product-moment correlation was used to determine if a correlation existed between HTV and selected biomechanical characteristics. The total group was also divided into two sub-groups of 32, one group with the fastest HTV (Hi-HTV) and the other with the slowest HTV (Lo-HTV). Single factor ANOVAs were completed for HTV and each selected biomechanical parameter. No significant differences were found between the Hi-HTV and Lo-HTV groups for both clubhead speed and driving accuracy. Lead forearm supination velocity at impact was found to be significantly different between groups with the Hi-HTV group having a higher velocity. Lead wrist extension velocity at impact, while not being significantly different between groups was found to be positive in both groups, meaning that the lead wrist is extending at impact. Lead wrist ulnar deviation, lead wrist release and trail elbow extension velocities at maximum were not significantly different between groups. Pelvis rotation, thorax rotation, pelvis side bend and pelvis rotation at impact were all significantly different between groups, with the Lo-HTV group being more side bent tor the trail side and more open at impact. These results suggest that world class golfers can successfully use either the low or high HTV technique for a successful swing. From an instructional perspective it is important to be aware of the body posture and wrist/forearm motion differences between the two techniques so as to be consistent when teaching either method. / Dissertation/Thesis / Doctoral Dissertation Exercise Science 2014
196

Acurácia do estridor para o diagnóstico de estenose subglótica por intubação em pacientes pediátricos

Enéas, Larissa Valency January 2013 (has links)
Objetivos: Determinar a acurácia do estridor em predizer a ocorrência de estenose subglótica (ESG) por intubação em pacientes pediátricos quando comparado ao seu diagnóstico por endoscopia de via aérea. Delineamento: Coorte Prospectiva. Métodos: Foram elegíveis todas as crianças de 28 dias a quatro anos de idade internadas na Unidade de Terapia Intensiva Pediátrica do Hospital de Clínicas de Porto Alegre que necessitaram de intubação endotraqueal por mais de 24 horas. Foram excluídas as com história de intubação, doença laríngea prévia, presença de traqueostomia atual ou no passado, presença de malformações craniofaciais e aquelas consideradas portadoras de doença terminal. Foram acompanhadas diariamente e, após a extubação, submetidas à fibronasolaringoscopia (FNL). Novo exame era realizado em sete a dez dias naquelas com alterações moderadas a graves no primeiro. Se essas persistissem ou surgissem sintomas, independentemente da FNL inicial, realizava-se laringoscopia sob anestesia geral. Após a extubação, verificou-se diariamente a ocorrência de estridor, classificado como presente ou ausente. Resultados: Foram acompanhados, de novembro de 2005 a agosto de 2012, 194 pacientes. A incidência de estridor pós-extubação foi de 43,81%. O estridor apresentou uma sensibilidade de 77,78% (IC 95%: 51,9 – 92,6) e especificidade de 59,66% (IC 95%: 52,0 – 66,9) em detectar ESG nessa amostra, o valor preditivo positivo (VPP) foi de 16,47% (IC 95%: 9,6 – 26,4) e o valor preditivo negativo (VPN) foi de 96,33% (IC 95%: 90,3 – 98,8). O estridor quando presente por mais de 72 horas ou quando esse surgiu após as primeiras 72 horas da extubação apresentou uma sensibilidade de 66,67% (IC 95%: 41,2 – 85,6) e especificidade de 88,5% (IC 95%: 83,1 – 93,1). O VPP foi de 38,8% (IC 95%: 22,4 – 57,7) e o VPN foi de 96,23 (IC 95%: 91,6 – 98,5). A área da curva ROC foi 0,78 (IC 95%: 0,65 – 0,91). Conclusões: A ausência de estridor mostrou-se adequada para afastar o diagnóstico de ESG por intubação em pacientes pediátricos após o período neonatal. Melhor especificidade foi encontrada quando o estridor ocorreu por mais de 72 horas após a extubação ou quando teve o início depois desse período. A partir desse estudo, parece adequado indicar endoscopia de via aérea, para a confirmação de ESG, apenas naqueles pacientes que apresentarem estridor após 72 horas da extubação. / Objective: To determine the accuracy of stridor in predicting the occurrence of postintubation subglottic stenosis (SGS) in pediatric patients when compared with endoscopy airway diagnosis. Design: Prospective cohort. Methods: Children aged 28 days to four years admitted to the Pediatric Intensive Care Unit of Hospital de Clinicas de Porto Alegre who required endotracheal intubation for more than 24 hours were eligible for study. Patients with previous intubation, history of laryngeal disease, current or past tracheostomy, presence of craniofacial malformations and those considered terminal by the staff were excluded from the study. Children were monitored daily and underwent flexible fiberoptic laryngoscopy (FFL) after extubation. Those who presented moderate to severe abnormalities in this first examination underwent another FFL between 7 and 10 days later. If these lesions persisted or symptoms developed, regardless of the findings in initial examination, laryngoscopy under general anesthesia was warranted. Occurrence of stridor was verified daily after extubation and classified as either present or absent. Results: We followed 194 children between November 2005 and August 2012. The incidence of post-extubation stridor was 43.81 per cent. Stridor had a sensitivity of 77.78% (CI 95%: 51.9 – 92.6) and specificity of 59.66% (CI 95%: 52.0 – 66.9) to detect SGS in this sample. The positive predictive value (PPV) was 16.47% (CI 95%: 9.6 – 26.4) and the negative predictive value was 96.33% (CI 95%: 90.3 – 98.8). Stridor, when present more than 72 hours or when started after these first 72 hours after extubation, showed a sensitivity of 66.67% (CI 95%: 41.2 – 85.6), specificity of 88.5% (CI 95%: 83.1 – 93.1), PPV of 38.8% (CI 95%: 22.4 – 57.7) and NPV of 96.23% (CI 95%: 91,6 – 98,5). ROC curve area was 0,78 (CI 95%: 0.65 – 0.91). Conclusions: Absence of stridor proved to be adequate to rule out the diagnosis of post-intubation SGS in pediatric patients. Improved specificity was found when stridor occurred for more than 72 hours after extubation or when started after that. From this study, it seems appropriate to indicate airway endoscopy under general anesthesia for the confirmation of SGS only in those patients who present stridor after 72 hours following extubation.
197

Caracterização de componentes inorgânicos em suplementos nutricionais pelo método de análise por ativação com nêutrons

REIS, ROGERIO A. de S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:31Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:00Z (GMT). No. of bitstreams: 0 / O controle da composição dos elementos presentes nos suplementos nutricionais é de grande importância devido ao crescente consumo e a comercialização de diversos tipos e marcas destes produtos. A determinação da quantidade de elementos nos suplementos torna – se necessária para comparar com os valores declarados nos seus rótulos. Neste trabalho, a ativação com nêutrons foi aplicada à análise de 11 amostras de suplementos, adquiridos em farmácias e em lojas de produtos naturais. As amostras, adquiridas nas formas de cápsulas ou comprimidos foram moídas para se obter as na forma de pó homogêneo. As amostras e os padrões sintéticos dos elementos foram irradiados no reator nuclear de pesquisas IEA-R1. Irradiações de 8 h sob um fluxo de nêutrons térmicos de 5x1012 n cm –2 s-1 foram realizadas para a determinação dos elementos Ca, Co, Cr, Fe, Se e Zn e para a determinação dos elementos As, Cu, Fe, K, Na as amostras foram irradiadas por 1 h sob fluxo de nêutrons térmicos da ordem de 1x1012 n cm –2 s-1. As medidas das atividades gama induzidas foram realizadas usando um detector de Ge hiperpuro acoplado a um espectrometro de raios gama. Os resultados das quantidades obtidas nas amostras de suplementos foram em geral, concordantes com os valores apresentados nos seus respectivos rótulos. Elementos tóxicos como As, Cd, Hg e Sb não foram detectados em nenhuma das amostras. Para o controle da qualidade dos resultados analíticos com relação à exatidão e precisão foram analisados os materiais certificados de referência NIST 1400 Bone Ash e NIST 1633b Coal Fly Ash ambos da National Institute of Standards and Technology (NIST). Os resultados obtidos nestes materiais de referência apresentaram uma boa precisão e exatidão e os valores de Z score ou diferença padronizada obtidos das análises, foram menores que 2 indicando que os resultados obtidos são satisfatórios e estão dentro da faixa dos valores dos certificados a um nível de confiança de 95%. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
198

Padronizacao de um metodo de HPLC em fase reversa para determinacao de prolactina em extratos bacteriano e em sua forma purificada: sua aplicacao em estudo colaborativo internacional promovido pela O.M.S

VIANNA, ELIZABETH K.G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:47:57Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:45Z (GMT). No. of bitstreams: 1 08712.pdf: 2365459 bytes, checksum: 3be7f0aa24629302df9709de6db64f86 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
199

Caracterizacao e otimizacao analitica na determinacao de trialometanos em aguas potaveis por purga e armadilha acoplada a cromatografia a gas / Analytical characterization and optimization in the determination of trihalomethanes on drinking water by purge and trap coupled to a gas chromatography

COSTA JUNIOR, NELSON V. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:35Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:31Z (GMT). No. of bitstreams: 0 / Neste trabalho desenvolveu-se uma metodologia analítica para determinação do teor de trialometanos THMs em amostras de águas potáveis, utilizando a técnica de purga e armadilha acoplada à cromatografia a gás (GCPT). Os THMs são subprodutos da cloração da água que devem possuir um limite máximo de 100 μg.L-1 segundo a legislação brasileira, estes compostos são suspeitos carcinogênicos humanos com base em estudos em animais de laboratório. A técnica de purga e armadilha extrai eficientemente estes compostos da água e a separação no cromatógrafo a gás ocorre utilizando coluna de leve polaridade e detector por captura de elétrons. Este detector é seletivo e o mais sensível para estes compostos halogenados. A metodologia desenvolvida foi validada nos itens de: linearidade, seletividade, exatidão, precisão, limite de quantificação, limite de detecção e robustez. O limite de detecção para os THMs foi menor do que 0,5 μg.L-1. A exatidão e precisão foram adequadas para ensaios de compostos traços. As amostras de água potável foram coletadas na cidade de Suzano-SP, que pertence à região do Alto do Tietê, nesta região nas margens do rio a vegetação é predominante. Entre todos os THMs, o composto encontrado na água potável em maiores concentrações foi o clorofórmio onde os resultados quantitativos, utilizando esta metodologia apresentaram teores entre 15,9 à 111,0 μg.L-1 em águas potáveis. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
200

Proposta de classificação de linhas de base obtidas com dados GPS, à luz de árvore de decisão / Proposal for classification of baselines obtained with GPS data, in light of decision tree

Mélodie Kern Sarubo Dorth 17 May 2010 (has links)
Ao se efetuar levantamentos utilizando a tecnologia GNSS, o processamento desses dados, bem como uma análise dos fatores oriundos dos processamentos e a correta interpretação dos resultados obtidos, consiste em fator primordial para se definir a qualidade de um levantamento. Contudo, os resultados estatísticos fornecidos pelos softwares comerciais após o processamento e ajustamento dos dados, apesar de garantir maior confiabilidade aos levantamentos, não fornecem a acurácia das coordenadas encontradas, apresentando apenas a sua precisão. Assim, este trabalho tem por objetivo final, fornecer uma tabela onde seja possível, através de uma comparação dos resultados oriundos dos processamentos, classificar a acurácia dos mesmos. Para tanto, foram efetuados os processamentos e ajustamentos de dados inerentes as quatro estações do ano, durante os anos de 2006, 2007 e 2008, e após adequada análise dos mesmos, foi implementada uma Tabela de Acurácia Recomendada, onde os profissionais da área de mensuração poderão, através de uma comparação entre os relatórios de processamento fornecidos e os itens da referida tabela, efetuar a classificação da acurácia dos trabalhos de interesse. / When making surveys using GNSS technology, the processing of these data, as well as an analysis of the factors resulting from the processing and the correct interpretation of results, is to prime factor for defining the quality of a survey. However, the statistics provided by commercial software after processing and adjustment of the data, while ensuring high reliability of surveys, do not provide the accuracy of the coordinates found, showing only its precision. This paper aims to provide a table where possible, by comparing the results from the processing, The classification accuracy of them. To do so, we made adjustments and the processing of data relating the four seasons, during the years 2006, 2007 and 2008, and after proper analysis of the same purpose, a Table of Accuracy Recommended where professionals in the area of measurement may, through a comparison between the reports provided and processing the items of the tariff, to perform the classification accuracy of the work of interest.

Page generated in 0.063 seconds