• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 210
  • 10
  • 10
  • 10
  • 10
  • 9
  • 7
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 220
  • 210
  • 117
  • 105
  • 89
  • 68
  • 45
  • 33
  • 28
  • 25
  • 24
  • 23
  • 23
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Avaliação da adesão de Staphylococcus spp. em resina acrílica específica para prótese ocular e alteração de cor de botões de íris artificiais, variando a cor e as técnicas de obtenção, ambos após desinfecção química /

Moreno, Amália. January 2014 (has links)
Orientador: Marcelo Coelho Goiato / Co-orientador: Daniela Micheline dos Santos / Banca: Eduardo Piza Pellizzer / Banca: Humberto Gennari Filho / Banca: Simone Cecílio Hallak Regalo / Banca: Célia Regina Moreira Lanza / Resumo: As próteses oculares são responsáveis pela recuperação da estética e auto-estima do usuário. Assim, os materiais utilizados na confecção de prótese ocular devem possuir propriedades específicas para sua indicação e durabilidade principalmente aos procedimentos de desinfecção pelo paciente. Desse modo, este estudo teve como objetivo verificar a efetividade de diferentes soluções desinfetantes na remoção de biofilme de duas espécies de Staphylococcus spp., desenvolvidas na superfície de resina acrílica específica para prótese ocular e avaliar a alteração de cor de botões de íris artificiais confeccionadas por diferentes técnicas antes e após a polimerização e quando influenciadas pela desinfecção química. Para o teste de microbiologia, 396 amostras em resina acrílica para prótese ocular N1 foram confeccionadas (1,0 cm em diâmetro e 0,3 cm em espessura), sendo metade dessas amostras para formação de biofilme de S. epidermidis e a outra metade para formação de biofilme de S. aureus, ambos na superfície da amostra. Para cada cepa bacterina, 66 amostras foram submetidas a formação de biofilme em sua superfície durante três diferentes tempos: inicial (24h), intermediário (48h) e maduro (72h). Em seguida as amostras foram distribuídas aleatoriamente (unidade amostral n=6) para um dos tratamentos desinfetantes: água destilada durante 10, 15, 30 min e 6 h (controle-CTL); sabão neutro (NES) durante 30 min; Opti-Free durante 30 min e 6 h; Efferdent (EFF) durante 15 min; e gluconato de clorexidina (0,5%; 2% e 4%) (CHX) durante 10 min. Após o tratamento desinfetante, as amostras acrílicas foram imediatamente agitadas para desprendimento do biofilme. A contagem de colônias foi verificada por análise do número de UFC/mL. Para a análise de alteração de cor 300 amostras simulando próteses oculares foram confeccionadas, sendo metade... / Abstract: Considering that ocular prostheses restore esthetics and patient's self-esteem, the materials used for prosthesis fabrication should present appropriate properties regarding indication and reliability after the disinfection procedures. So, the aim of this study was to assess the effectiveness of different disinfectant solutions against two species of Staphylococcus spp. cultured on ocular prosthesis acrylic resin. In addition, the chromatic change of artificial iris buttons fabricated with different techniques was also evaluated before and after polymerization and disinfection. For the microbiology tests 396 acrylic specimens were fabricated (1.0 cm in diameter and 0.3 cm in thickness). Half of the samples were made for biofilm formation of S. epidermidis and half were made for biofilm formation of S. aureus, both on the sample surface. For each strain, 66 samples were underwent to biofilm formation on the liner surface for three different points: initial (24h), intermediate (48h) and mature (72h). Afterwards the specimens were randomly assigned (unit sample n = 6) to one of disinfectant treatments: distilled water for 10, 15, 30 min and 6 h (control-CTL); treated with neutral soap (NES) for 30 min; treated with Opti-Free (OPT) for 30 min and 6 h; treated with Efferdent (EFF) for 15 min; and treated with (0.5%, 2% and 4%) chlorhexidine gluconate (CHX) for 10 min. After the treatments, the specimens were vortexed to disrupt the biofilm, and residual cells were counted (cell/mL). For the color meansurations a total of 300 samples simulating ocular prosthesis were fabricated. Half of the samples were made with blue artificial irises, and half were made with brown artificial irises. For each color, 50 samples were fabricated according to one of the following techniques: PE - conventional technique, CA - prefabricated... / Doutor
92

Formulación y comportamiento de pinturas anticorrosivas acrílicas base agua

Noriega, María E., Flores, Santiago E., Caprari, Juan J. 25 September 2017 (has links)
El presente trabajo ha consistido en desarrollar formulaciones y elaborar, en laboratorio, pinturas anticorrosivas acrílicas base agua y con pigmentos de fosfato de zinc, utilizadas para la protección del acero común como una alternativa ecológica a las pinturas convencionales base solvente. Estas formulaciones han sido evaluadas en ensayos de corrosión acelerada y en un ensayo de larga duración en una atmósfera urbano-marina. Los resultados obtenidos han demostrado que los anticorrosivos acrílicos base agua pueden ofrecer similar protección e incluso superior (ensayos de corrosión acelerada) que algunas pinturas convencionales base solvente de uso común. Siendo las pinturas anticorrosivas base agua una tecnología en desarrollo en países Iberoamericanos, las formulaciones obtenidas constituyen una alternativa ecológica y de bajo impacto ambiental que pueden reemplazar a las pinturas convencionales base solvente y pigmentadas con metales pesados, para la protección del acero en ambientes medianamente agresivos.
93

Resistencia ao impacto e morfologia de fratura de resinas acrilicas processadas por energia de microondas e banho de agua quente / Impact strenght and fracture morphology of heat and microwaves polymerized acrylic resins

Costa, Marcelo de Almeida 30 August 2005 (has links)
Orientador: Renata Cunha Matheus Rodrigues Garcia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-05T11:29:35Z (GMT). No. of bitstreams: 1 Costa_MarcelodeAlmeida_M.pdf: 3239895 bytes, checksum: cf5932b7fd5f5024e8d16d48a3f2b663 (MD5) Previous issue date: 2005 / Resumo: Foi objetivo deste trabalho avaliar a resistência ao impacto e morfologia de fratura de resinas acrílicas processadas por microondas e banho de água quente. Foram confeccionados 20 corpos-de-prova por grupo medindo 65x10x2,5mm para as resinas: Lucitone 550 (74oC/9 horas); Onda Cryl (3 minutos/360W, 4 minutos/pausa, 3 minutos/810W); Acron MC (3 minutos/500W) e Vipi Wave (20 minutos/180W, 5 minutos/540W). A resistência ao impacto foi avaliada em máquina Otto Wolpert Werke pelo método Charpy, com energia de carga de 40 Kp.cm (3,9466J), e as fraturas classificadas em frágeis ou intermediárias. A fractografia foi realizada por análise dos ângulos de propagação das fendas, e a caracterização morfológica microestrutural por observação em microscopia eletrônica de varredura (MEV). Os resultados de resistência ao impacto foram submetidos ao teste de Tukey e para comparação dos ângulos A e B dos fragmentos fraturados, foi aplicado o teste de Kruskal-Wallis e Coeficiente de Pearson. Foram observadas diferenças (p<0,01) para a resistência ao impacto, sendo que a resina Vipi Wave apresentou o menor valor. A maioria das fraturas foi classificada como frágil (Lucitone 550=56%, Onda Cryl=75%, Acron MC=90%, Vipi Wave=65%). A análise angular das fraturas frágeis não evidenciou diferenças, entretanto para fraturas intermediárias a resina Onda Cryl diferiu (p<0,01) das demais. A MEV evidenciou que fraturas frágeis apresentam planos cristalográficos definidos e organizados, enquanto que as intermediárias apresentam grau de desorganização. Conclui-se que resinas de microondas apresentam resistência ao impacto semelhante às de banho de água quente, e independente do processamento, as resinas apresentaram maior número de fraturas frágeis / Abstract: The aim of this study was to evaluate to the impact to resistance and morphology of processed acrylic resin breaking for microwaves and hot water bath. 65x10x2,5mm for resins had been confectioned 20 samples measuring: Lucitone 550 (74ºC/9 hours); Cryl wave (3 minutes/360W, 4 minutes/brake, 3 minutes/810W); Acron MC (3 minutes/500W) and Vipi Wave (20 minutes/180W, 5 minutes/540W). The impact to resistance was evaluated in machine Otto Wolpert Werke for the Charpy method, with load of 40 Kp.cm (3,9466J), and breakings classified in the fragile or intermediate. The fractography was carried through by analysis of the angles of propagation of the cracks, and the microstructural morphologic characterization for comment in electronic microscopy of sweepings (MEV). The results of impact to resistance had been submitted to the test of Tukey and for comparison of the angles the test of Kruskal-Wallis and coefficient of Pearson was applied. Differences (p<0,01) had been observed for the impact to, being that the resin Vipi Wave presented the lesser value. The majority of the breakings were classified as fragile (Lucitone 550=56%, Onda Cryl=75%, Acron MC=90%, Vipi Wave=65%). The angular analysis of the fragile breakings did not evidence differences, however for intermediate breakings the resin Onda Cryl differed (p<0,05) of excessively. The MEV evidenced that fragile breakings present definite and organized cristalgraphic plans, while that the intermediate present disorganization degree. One concludes that resins of microwaves present resistance to the similar impact to the ones of hot water bath, and independent of the processing, the resins had presented greater number of fragile breakings / Mestrado / Protese Dental / Mestre em Clínica Odontológica
94

Influencia de tecnicas de polimerização sobre adaptação das bases de protese total

Almeida, Maria Helena Waack de 30 April 1998 (has links)
Orientadores: Saide Sarckis Domitti, Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T15:36:03Z (GMT). No. of bitstreams: 1 Almeida_MariaHelenaWaackde_M.pdf: 4543291 bytes, checksum: e498330720bead407e49365e84feda17 (MD5) Previous issue date: 1998 / Resumo: O objetivo desta pesquisa foi verificar as alterações de adaptação das bases de prótese total, confeccionadas com resina acrílica ativada termicamente, ocorridas sob a influência de 3 técnicas de polimerização: convencional, por calor seco e por energia de microondas. Foram confeccionados 30 modelos padrões em gesso pedra, a partir de um molde de borracha representando uma arcada superior desdentada normal. Sobre os modelos foram confeccionadas as bases de prova, que foram divididas aleatoriamente em 3 grupos de 10 elementos e incluídos. em mufla pela técnica convencional, a fim de receber os seguintes tratamentos experimentais: Grupo 01: prensagem com resina termopolimerizável (Clássico) e polimerização em banho de água aquecida a 74+2°C por 9 horas (método convencional). Grupo 02: prensagem com resina termopolimerizável (Clássico) e polimerização por calor seco (estufa) a 74+2°C por- 9 horas. Grupo 03: prensa$em com resina termopolimerizável (Acron MC) e polimerização em forno de microondas a 900 W por 3 minutos. A seguir, as bases em resina, limpas e acabadas, foram fixadas em seus respectivos modelos com adesivo instantâneo (Super Bonder). O conjunto base de prótese modelo de gesso foi posicionado e fixado em um aparelho específico para obtenção das secções. Orientados por .guias existentes na mesa de fixação, com auxílio de serra manual, foram executados 3 cortes látero laterais passando pela região correspondentes à distal de caninos direito e esquerdo (A), mesial de primeiros molares direito e esquerdo (B) e região "pos-dam" (C) e 3 cortes ântero-posteriores passando pela região correspondente à crista do rebordo direito (A) e esquerdo (C) e região mediana do palato (B). A alteração dimensional ocorrida na resina acrílica foi avaliada por meio de um microscópio comparador, em 5 pontos referenciais para cada tipo de corte. Os resultados numéricos obtidos foram submetidos à análise estatística e as médias ao Teste de Tukey ao nível de significância de 5%. Todas as técnicas avaliadas produziram distorções, sem diferença estatisticamente significante. Quando o desajuste foi analisado dentro de uma mesma técnica, verificou-se que no Grupo 01 (Termopolimerizadora) não houve diferença estatisticamente significante entre os cortes látero-laterais. Entretanto, no Grupo 02 (Estufa), o corte A foi semelhante ao B e o B ao C, enquanto no Grupo 03 (Microondas), os dados demonstraram o mesmo comportamento estatístico entre os cortes B e C, porém diferentes do A, que mostrou a melhor adaptação. Por outro lado, quando os cortes ântero-posteriores foram analisados, houve comportamento estatístico semelhante entre eles nas 3 técnicas de polimerização estudadas. Neste caso, o corte B foi diferente estatisticamente dos cortes A e C, mostrando o maior desajuste. Independente da técnica de polimerização e da localização dos cortes; não houve diferença estatística quando se comparou os índices de desajuste entre os cortes látero-Iaterais e ântero-posteriores / Abstract: The purpose of this study was to veri1)1 the denture bases accuracy, made with heat-cured acrylic resin, occurred under the influence of three cycles of polymerization: conventional, by dry heat and with microwave. energy. Thirty master cast were made in stone plaster from a rubber cast, representing a normal nondental arch. The experimental bases were made on the casts which were divided at randon into three groups of ten elements and included in flask by conventional technique in order to receive the following experimental treatments: Group 01: press with thermicpolymerized resin (Clássico) and polymerized with hot water bath at 74+2°C during 9 hours (conventional method). Group 02: press with thermic-polymerized resin (Clássico) and polymerized with dry heat (oven) at 74+2°C during 9 hours. Group 03: press with thermicpolymerized resin (Acron MC) and polymerized in microwave oven at 900 W during 3 minutes. Afterly the bases in clean and tlnished resin were atlxed on their casts with instantaneous adhesive. The plaster model-prosthesis bases set was positioned and atlxed on an especitlc instrument to obtain the sections. Guided by instruments on tlxation grip, with the aid of a manual saw, three saggital plane cuts were made on the corresponding region to the right crest of ridge (A) and left (C) and on the palatal median region (8) and 3 lateral plane cuts corresponding to the distal of right and left canines (A), right and left tlrst molars mesial (8) and pos-dam region (C). The occurred dimensional alteration on the acrylic resm was evaluated with a comparator microscope in 5 referential points to each kind of cut. The numerical results were submited to a statistical analysis and the averages by the Tukey Test to a significance levei of 5%. AlI the evaluated techniques caused distortions, without statistical significative difference. There wasn't any statistical significative difference on the sagittal plane and lateral plane cuts among the three studied polymerization techniques. When the disadjustement was analysed within the same techniques, it was verified that in Group 01 (thermicpolymerizer) there was no statistical significative difference among the lateral plane cuts. However, in group 02 (Oven), the cut A was similar to B and B to C and in group 03 (Microwaves) the datas showed the same statistical conduct between cuts B and C, but different from cut A, which showed the best adaptation . On the other hand, when the sagittal plane cuts were analys~d, there was a similar statistical conduct among them on the three studied polymerization techniques. In this case, the cut B was statisticalIy different from cuts A' and C, showing the biggest disadjustment / Mestrado / Protese / Mestre em Clínica Odontológica
95

Avaliação in vitro da dureza superficial de uma resina acrilica para microondas e rugosidade da mesma e de duas ligas metalicas quando submetidas a agentes quimicos de limpeza

Souza Junior, Joane Augusto de 19 September 2001 (has links)
Orientador: Renata C. M. Rodrigues Garcia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T22:47:16Z (GMT). No. of bitstreams: 1 SouzaJunior_JoaneAugustode_M.pdf: 4774819 bytes, checksum: 9266daf23fd3dbe4444a1989bf160542 (MD5) Previous issue date: 2001 / Resumo: Foi propósito deste trabalho avaliar a dureza superficial de uma resina acrílica polimerizada por energia de microondas, bem como a rugosidade desta mesma resina e de duas ligas metálicas: Co-Cr e Ti-6Al-4V, quando imersas em duas soluções de limpeza de próteses. Foram confeccionadas 48 amostras de resina Onda-Cryl contendo uma barra metálica exposta em uma das faces. Oito amostras contendo a liga de Co-Cr foram imersas em solução limpadora Polident (GI), oito em solução de limpeza confeccionada em farmácia de Manipulação (G2), e oito em água (Controle - G3); o mesmo se repetindo para amostras contendo a liga de Ti-6Al-4V (G4, G5 e G6, respectivamente). Todas as amostras foram mantidas em saliva artificial à 37°C e imersas nas respectivas soluções de limpeza durante 5 minutos, 3 vezes ao .dia. As avaliações da dureza e rugosidade foram realizadas imediatamente após o polimento das amostras (TO), e após 1 (TI), 15 (T2) e 30 dias (T3). A dureza superficial foi avaliada em microdurômetro Shimadzu HMV -200 e a rugosidade em rugosímetro Surfcorder SE 1700. Os resultados foram submetidos à análise estatística e demonstraram que: a) para a dureza da resina acrilica houve diferenças significantes para os grupos GI e G4 nos tempos TI e T3 (14,028::t2,784; I4,056::tI,76I) e grupo G2 e G5 no tempo T2 (I6,992::t2,243); b) para a rugosidade da resina acrílica os resultados diferiram para os grupos GI e G4 nos tempos T2 e T3 (0,I44::tO,062; 0,209::tO,383); c) para a rugosidade na liga de Co-Cr, o grupo G2 (0,1O4::tO,035) diferiu dos demais grupos no tempo TI; e o grupo GI (0,I48::tO,OI6) diferiu dos demais grupos nos tempos T2, e no tempo T3 todos os grupos diferiram entre si; e d) para a rugosidade na liga de Ti-6Al-4V, o grupo G4 diferiu dos demais grupos nos tempos T2 (0,lI9::tO,OO5) e T3 (0,lO8::tO,O37). Com relação às ligas, o grupo G3 (0,083i:0,018) diferiu de G6 no tempo TO, e o grupo G6 (2,354i:0,767) diferiu de G3 no tempo T3. Concluí-se que o agente químico de limpeza Polident diminui a dureza da resina acrílica e não interfere na rugosidade desta e das ligas estudadas, e que o limpador de Manipulação aumenta a rugosidade em ambos os materiais estudados / Abstract: The aim of this study was to evaluate the Knoop hardness and roughness of microwave acrylic resin and the roughness of two metal alloys: Co-Cr and Ti-6Al-4V when immersed into two denture cleansers. Forty-eight samples of Onda-Cryl acrylic resin were made with a metallic bar exposed in one side. Eight samples with Co-Cr alloy were immersed in denture cleanser Polident (G 1 ), eight in denture cleanser made in Manipulation pharmacy (G2), and eight in water (Control) (G3); the same procedure was repeated with Ti-6Al-4V samples (G4, G5 and G6, respectively). All samples were kept in synthetic saliva at 37°C and immersed in the soIutions during 5 minutes, 3 times a day. The Knoop hardness and roughness were verified immediately after polishing (TO), and after 1 (TI), 15 (T2), 30 (T3) days.' The Knoop hardness was evaluated using microhardness Shimadzu IIl / Mestrado / Protese Dental / Mestre em Clínica Odontológica
96

Influencia da tecnica de caracterização intrinseca sobre a dureza, rugosidade superficial e porosidade de uma resina acrilica em diferentes tempos pós-prensagem

Almeida, Marco Antônio Borges de 04 September 2001 (has links)
Orientador: Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T22:44:32Z (GMT). No. of bitstreams: 1 Almeida_MarcoAntonioBorgesde_M.pdf: 5917806 bytes, checksum: 9fe425ba0979361a5689e9725739a1d5 (MD5) Previous issue date: 2001 / Resumo: O objetivo deste estudo foi avaliar a influência da técnica de caracterização intrínseca sobre a dureza, rugosidade superficial e ocorrência de porosidade de uma resina acrílica ativada termicamente em forno de microondas em diferentes tempos pós-prensagem (1/2, 2, 6, 12 e 24 horas). Foram confeccionadas 270 amostras em resina acrílica, sendo metade produzida pela técnica convencional com resina incolor (M1) e metade pela técnica de caracterização intrínseca (M2). Todas as amostras foram polimerizadas em forno de microondas em ciclo de 6 minutos a 40% de potência, intervalo de 5 minutos a 0% de potência e 3 minutos a 80% de potência. Após a polimerização as amostras foram desincluídas e receberam acabamento e polimento padronizado. Foram realizados ensaios de dureza Knoop em um microdurômetro HM V-200O (SHIMADZU), rugosidade superficial em um rugosímetro SURFCORDER SE 1700 (KOSAKA LAB) e verificada a ocorrência de porosidade em uma lupa estereoscópica MG 63A (CARL ZEISS). Além disso foram realizadas observações em microscopia eletrônica de varredura da morfologia superficial das amostras e das fibras de caracterização. Os dados obtidos foram analisados estatisticamente por Análise de Variância e pelo Teste F. Os resultados médios obtidos para dureza Knoop (KHN) e rugosidade superficial (JJm), parâmetros Ra e Rz, foram para o Grupo M1: 18,25; 0,0587 e 0,3474 e para o Grupo M2: 18,04; 0,0795 e 0,5375, respectivamente. A análise dos resultados permitiu concluir que: não houve influencia do tempo pós-prensagem sobre as propriedades estudadas; a dureza superficial da resina acrílica caracterizada foi estatisticamente semelhante à da incolor obtida de modo convencional; os valores de rugosidade superficial média da resina caracterizada foram superiores aos da incolor; a ocorrência de porosidade foi desprezível em todos os grupos avaliados / Abstract: The aim of this study was to evaluate the influence of the intrinsic characterization technique on hardness, surface roughness and porosity of a microwave cured acrylic resin in different post packing and press periods (1/2, 2, 6, 12 and 24 hours). 270 samples of acrylic resins were prepared. Half of them were prepared by the conventional technique using clear resin (M1) and the other half by the intrinsic characterization technique (M2). Ali samples were cured in a microwave oven in cycle of 6 minutes at 40% potency, 5 minutes at 0% potency and 3 minutes at 80% potency. After cured the samples were deflasked, finished and polished. Knoop microhardness assay was performed in a microhardness teste r HM V-200O (SHIMADZU), surface roughness assay was conducted in a profilometer SURFCORDER SE 1700 (KOSAKA LAS) and the occurrence of porosity was verified by means of a stereoscopic magnifying glass MG 63A (CARL ZEISS). In addition, scanning electron microscopy was used to observe the surface texture of the samples and characterization fibers. ANOVA and F-test statistically analyzed the data. The mean results of Knoop hardness (KHN), surface roughness Ra and Rz parameters (j.Jm) were: 18,25; 0,0587 and 0,3474 in M1 Group and 18,04; 0,0795 and 0,5375 in M2 Group, respectively. Based on the results analysis it was concluded that: post packing and press periods did not influence the studied properties; the surface hardness of the characterized acrylic resin was similar to the surface hardness of the clear acrylic resins; the mean values of surface roughness of the characterized acrylic resin were higher than those of the clear acrylic resin; the occurrence of porosity was negligible in ali evaluated groups / Mestrado / Protese Dental / Mestre em Clínica Odontológica
97

Influencia da posição e do numero de muflas no microondas sobre a liberação de monomero residual, dureza de superficie e porosidade da resina acrilica Acron MC

Oliveira, Viviane Maia Barreto de 15 May 2001 (has links)
Orientadores : Simonides Consani, Altair A. Del Bel Cury / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T04:17:30Z (GMT). No. of bitstreams: 1 Oliveira_VivianeMaiaBarretode_M.pdf: 4121835 bytes, checksum: 84cf24ddd5946bfc165c1098158f7242 (MD5) Previous issue date: 2001 / Resumo: Existem dúvidas quanto à eficácia da polimerização quando mais de uma mufla é inserida simultaneamente no microondas. O objetivo deste trabalho foi avaliar a influência da posição e do número de muflas sobre a liberação de monômero residual (MR), porosidade superficial (P) e dureza Knoop (D) da resina Acron MC polimerizável em microondas. Foram confeccionados 90 corpos-de-prova, medindo 32,5 x 10,0 x 2,5 mm polimerizados em microondas a 500 W, considerando como controle a posição da mufla no centro do prato giratório (GI) e, como grupos experimentais, as posições no centro (GUa) e na extremidade (GlIb) do prato, bem como a utilização de duas muflas centralizadas, uma sobre a outra (GUIa e GIIlb). O tempo de processamento variou de acordo com o número de muflas: 3 ou 4,5 minutos. para 1 ou 2 muflas, respectivamente. Para a liberação de monômero em água, cada amostra foi colocada em tubo de ensaio com 6 mL de água deionizada, e diariamente substituída. Os níveis de monômero foram obtidos em espectrofotômetro, a 206 nm, após 24, 48, 72, 96, 120 e 144 horas. Para o ensaio de dureza, 12 indentações foram feitas na superficie das amostras após 144 horas de armazenamento em água (37+-2° C), enquanto a porosidade superficial foi avaliada pela imersão das amostras em tinta nanquim e a leitura realizada em lupa estereoscópica com aumento de 40X. Os resultados encontrados foram: 1) Liberação de monômero quanto aos tratamentos: GI= 82,0(197,4)b, GIIa=44,1(98,l)b, GIIb= 63,9(183,0)b, GIIIa= 189,1 (436,)a, GIIIb= 26,1(88,8)c 2) Liberação de monômero quanto aos tempos: 24h= 335,8(501,3)a, 48h= 66,1 (146,0)b, 72h= 35,7(51,0)c, 96h= 19,6(21,9)c, 120h= 14,5(16,4)d, 144h= 14,7(19,1)d 3) Dureza de superficie: GI=18,1(3,5)a, GIIa=17,1(1,9)a, GIIb=16,3(3,2)a, GUIa=16,8(3,9)a, GIIIb=17,6(2,5)a; 4) Porosidade: GI=7,2(9,4)a, GIIa=19,3(36,0)a, GIIb=20,8(28,2)a, GIIIa=24,3(42,6)a, GIIIb=13,2(13,9)a Para análise estatística foi realizada a análise de variância (ANOV A) e o teste de Dunnet na análise da liberação de monômero quanto aos tratamentos e de Tukey na análise da liberação de monômero quanto aos tempos (p<O,O5). Assim, de acordo com os resultados obtidos, a posição das muflas interferiu na polimerização das resinas, quanto à liberação de monômero nos grupos GIIIa e GIIIb, porém não o fez em relação à dureza de superfície e porosidade / Abstract: In attempt to save working time, microwave-polymerized dentures can be processed simultaneously. However, little concern exists about possible uneven acrylic resin polymerization when inserting multiple flasks in a microwave oven. Thus, this .study evaluated the effect of number and position of flasks in the monomer release, Knoop hardness and porosity of a microwave-cured acrylic resin. Samples were made of Acron MC (AMC, GC lnt.) and processed under 500 W. The following flask number-position associations were tested: one simple flask centraI1y placed over the tuming plate (I control); two flasks, one in the center (IIa) and the other marginally placed in the plate (llb); two flasks centrally placed over the plate, one above (IIIa) and the other below (IIIb). The processing time varied according to the number of flasks: 3 minutes or 4.5 minutes for 1 or 2 flasks inserted, respectively. For monomer released in water, each specimen (18 in each group) was put in an assay glass tube containing 6 mL of deionized water, which was daily changed. Monomer levels were obtained by spectrophotometry at 206 nm, after 24, 28, 72, 96, 120 e 144 hours. For hardness test, 12 indentations were done in the surface of 12 specimens in each group, after 144 h of water storage. The porosity was verified by immersing the polished specimens in permanent ink, and counted through a stereo light microscope. The results found were: 1) Monomer release by groups: GI= 82,0(197,4)b, GIIa=44,1(98,l)b, GIIb= 63,9(183,0)b, GIIIa= 189,1 (436,)a, GIIIb= 26,1(88,8)c 2) Monomer release by time: 24h= 335,8(501,3)a, 48h= 66,1 (146,0)b, 72h= 35,7(51,0)c, 96h= 19,6(21,9)c, 120h= 14,5(16,4)d, 144h= 14,7(19,1)d 3) Knoop hardness: GI=18,1(3,5)a, GIIa=17,1(1,9)a, GIIb=16,3(3,2)a, GUIa=16,8(3,9)a, GIIIb=17,6(2,5)a; 4) Porosity: GI=7,2(9,4)a, GIIa=19,3(36,0)a, GIIb=20,8(28,2)a, GIIIa=24,3(42,6)a, GIIIb=13,2(13,9)a There was no statistical significant difference (p<O.O5) arnong all groups for Knoop hardness and porosity but the position of flasks interfere in the monomer release in GIDa and GIllb, using Tukey's and Dunnet's tests / Mestrado / Protese Dental / Mestre em Clínica Odontológica
98

Avaliação da adaptação, porosidade, resistencia a flexão e ao impacto de resinas acrilicas

Ganzarolli, Solimar Maria 17 May 2001 (has links)
Orientador : Altair Antoninha Del Bel Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T05:26:46Z (GMT). No. of bitstreams: 1 Ganzarolli_SolimarMaria_D.pdf: 4447523 bytes, checksum: 2a326decbe6e00e6c7ec27628b664bec (MD5) Previous issue date: 2001 / Resumo: A adaptação das bases de prótese evita a formação de hiperplasias e mantém uma adequada função mastigatória. A presença de porosidade pode levar a um acúmulo de Cândida albicans e diminuição da resistência da prótese. Foi propósito deste trabalho avaliar a adaptação e porosidade, resistência à flexão e ao impacto de três diferentes tipos de resinas acrílicas: termopolimerizável convencional Clássico (C), resina para polimerização em fomo de microondas Onda Cryl (O) e resina injetada Palaxpress (P). A avaliação da adaptação foi realizada imediatamente após a demuflagem (TI) e após um período de armazenagem por 30 dias (AA). Para verificar a desadaptação foi verificado o peso de silicone por adição (Express-3M) interposto entre a base de resina e o modelo metálico. A porosidade foi avaliada pelo peso de cada amostra em ar e água, em balança de precisão de 0,001 g. Para os testes de resistência à flexão e ao impacto, foram confeccionadas amostras de 65x10x2,5 mm. As médias e desvios padrões foram: para adaptação em gramas (g) TI; C= 0,573 :I: 0,037 (ab); 0= 0,640 :I: 0,061 (a); P= 0,503 :I: 0,062 (b); AA; C= 0,705 :I: 0,055 (a); 0= 0,696 :I: 0,051 (a); P= 0,583 :I: 0,087 (b). Quando comparados TI com AA, verificou-se uma distorção das 3 resinas utilizazdas. Para porosidade em cm3: C= 0,450:I: 0,052 (a); 0= 0,500 :I: 0,0 (ab); P= 0,590 :I: 0,128 (b); para resistência à flexão em Mpa: C= 81,970 :I: 7,999 (a); 0= 97,550 :I: 9,713 (b); P= 92,090 :I: 6,301 (b); para resistência ao impacto em Joules: C= 0,250:I: 0,0 (a); 0= 0,267 :I: 0,004 (b); P= 0,258 (:I: 0,006 (b). A análise de variância e a comparação utilizando o teste t mostrou diferença entre os grupos e as médias seguidas por letras diferentes mostraram diferença significativa «1=5%). Com estes resultados concluiu-se que a resina Palaxpress possui melhor adaptação se comparada com as resinas Clássico e Onda Cryl; e a resina Clássico apresentou menor porosidade e menor resistência à flexão e ao impacto quando comparada com as duas outras resinas utilizadas neste trabalh / Abstract: He adaptation of the prosthesis bases avoids hyperplasic formation, and it keeps an adequate function masticator. The presence of porosity can lead to microorganisms growing Cândida albicans, and decrease of the denture base strength. The aim this work was evaluates the adaptation, porosity, flexural and impact strength of 03 different kinds of acrylic resins: conventional heat cured Clássico (C), resin microwave active Onda Cryl (O) and injected resin Palaxpress (P). Adaptation assessment was performed immediately after for deflasking (TI) and after a storage period for 30 days (AA). To verify for desadaptation was accomplished the addition silicone weight (Express-3M) intervened between resin base and the metallic model. The porosity was evaluated by the weight of each sample in air and water, in precision balance of O.OOlg. For the flexural and impact strength, were made samples of 65XlOX2,5 mm. The means and standard deviations were: adaptation (g) TI; C= 0.573 ::t 0.037 (ab); 0= 0.640::t 0.061 (a); P= 0.503 ::t 0.062 (b); AA; C= 0.705 ::t 0.055 (a); 0= 0.696 ::t 0.051 (a); P= 0.583 ::t 0.087 (b). When compared TI with AA, to observed the expansion of 3 resins. Porosity (cm3): C= 0.450 ::t 0.052 (a); 0= 0.500 ::t 0,0 (ab); P= 0.590::t 0.128 (b); transverse strength (MPa): C= 81.970 ::t 7.999 (a); 0= 97.550 ::t 9.713 (b); P= 92.090::t 6.301 (b); impact strength (Joules): C= 0.250 ::t 0.0 (a); 0= 0.267 ::t 0.004 (b); P= 0.258 (::t 0.006 (b). The results of analysis of variance and the means comparison using t test showed difference between the groups. The means followed by different letters showed signicant difference (a=5%). It was conclude that: the resin Palaxpress owns better adaptation if compared with the Clássico resins and Onda Cryl, the Clássico resin introduced smaller porosity and smaller resistance the inflection and to the impact when compared with both other used resins in this work / Doutorado / Protese Dental / Doutor em Clínica Odontológica
99

Efeito da combinação de gessos de inclusão sobre a adaptação das bases de protese total superior

Almeida, Maria Helena Waack de 02 December 2001 (has links)
Orientadores : Saide Sarckis Domitti, Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T05:33:00Z (GMT). No. of bitstreams: 1 Almeida_MariaHelenaWaackde_D.pdf: 5508767 bytes, checksum: b03c3c13c9774dfa80be1f7537d1c28d (MD5) Previous issue date: 2001 / Resumo: O objetivo desta pesquisa foi verificar os efeitos da combinação de gessos de inclusão na adaptação das bases de prótese total superior, confeccionadas com resina acrílica ativada termicamente, polimerizadas de acordo com os seguintes ciclos: convencional, calor seco e energia de microondas. Foram confeccionados quarenta e cinco modelos padrões em gesso pedra, a partir de um molde de borracha representando uma arcada superior desdentada. Sobre os modelos foram confeccionadas quarenta e cinco bases de prova, divididas aleatoriamente em três grupos de quinze elementos cada, baseados no tipo do gesso utilizado durante a fase de inclusão dos modelos. No Grupo l, as bases de prova foram incluídas em mufla pela técnica convencional, utilizando-se gesso comum e pedra. No Grupo lI, utilizando-se gesso comum e especial, e no Grupo III, gesso pedra e especial. Cada Grupo foi subdividido em três subgrupos, de acordo com o ciclo de polimerização ao qual as amostras foram submetidas: Subgrupo 1: polimerização através do ciclo convencional (74+2°C por 9 horas); Subgrupo 2: polimerização por calor seco (74+2°C por 9 horas); e Subgrupo 3: polimerização através de energia de microondas (900 W por 3 minutos). A seguir, as bases em resina foram fixadas em seus respectivos modelos com adesivo instantâneo. O conjunto base de prótese-modelo de gesso foi posicionado, fixado e seccionado em aparelho específico onde foram executados três cortes látero-Iaterais: A (anterior), B (médio) e C (posterior). A alteração dimensional ocorrida na resina acrílica foi avaliada por meio de um microscópio comparador, em cinco pontos referenciais. Os resultados numéricos foram submetidos à análise de 1 variância e ao teste de Tukey (5%). Concluiu-se que, independente dos demais fatores, o ciclo convencional mostrou o maior desajuste das bases de prótese em relação aos modelos. Quando o tipo de inclusão foi analisado em relação ao fator ciclo de polimerização, verificamos que as inclusões Comum/Especial e Pedra/Especial não apresentaram valores com diferença estatística significativa. Na inclusão Comum/Pedra o ciclo convencional apresentou o maior desajuste. Quando o fator corte foi analisado em função do ciclo de polimerização, notamos que no corte A, o ciclo convencional apresentou o maior desajuste. Quando os cortes foram analisados independente de outros fatores, houve diferença estatística significativa entre eles. O maior desajuste ocorreu no corte C. Quando os cortes foram analisados em relação ao tipo de inclusão independente de outros fatores, verificamos que nas inclusões Comum/Especial e Pedra/Especial, o maior desajuste ocorreu no corte C. Quando o tipo de inclusão foi observado independente de outros fatores, verificamos que a inclusão Comum/Pedra apresentou o menor desajuste / Abstract: he purpose of this study was to verify the effects of the combination of inclusion plaster in the adaptation of upper denture bases, made with heat-cured acrylic resin, ocurred under the influence of three cycles of polymerization: conventional, by dry heat and with microwave energy. Forty-five master casts were made in stone plaster from a rubber cast representing upper nondental arch. The forty-five experimental bases were made on the casts which were divided at randon into three groups of fifteen elements, based on the kind of plaster used during the inclusion phase of the casts. The casts with the experimental bases from Group I were included in flask by conventional technique, using commum plaster and stone. In the Group II, using commum plaster and special, and the Group II stone plaster and special. Each group was subdivided into three subgroups, according the polymerization cycle to which the casts were submitted: Subgroup 1: polymerization through the conventional cycle (74 + 2°e for nine hours). Subgroup 2: polymerization by dry heat (74 + 2° e for nine hours) and Subgroup 3: polymerization in Microwave Oven (900 W for 3 minutes). Next, the bases in resin were fixed on their casts with instantaneous adhesive. The plaster model - prosthesis bases set was positined, fixed and cut on an especific instrument, three lateral plane cuts were made: A (anterior), B (median) and e (posterior). The occurred dimensional alteration on the acrylic resin was evaluated with a comparator microscope in five referential points. The numerical results were submitted to a variance analysis and the Tukey Test (5%). It was concluded that, independent of other factors, the conventional cycle showed the biggest disadjustment of the denture bases in relation to the casts. When the kind of inclusion was analysed in relation to the cycle fa cto r of polymerization, it was verified that the Commum/Special and Stone/Special inclusions did not show statistic significative difference. In the Commum/Stone inclusion the conventional cycle showed the biggest disadjustment. When the cut factor was analysed in relation to the polymerization cycle, it was verified that in the A cut, the conventional cycle showed the biggest disadjustment. When the cuts were analysed independent of other factors, there was significative statistic difference among them. The biggest disadjustment occurred in the C cut. When the cuts were analysed in relation to the kind of inclusion independent of other factors, it was verified that in the Commum/Special and Stone/Special inclusions, the biggest disadjustment occurred in the C cut. When the kind of inclusion was analysed independent of other factors, it was verified that the Commum/Stone inclusion showed the smallest disadjustment / Doutorado / Protese / Doutor em Clínica Odontológica
100

Resistencia ao impacto da união dente-resina acrilica sob efeito da desinfecção simulada por energia de microondas / Effect of simulated microwave disinfection on bond strength of acry teeth and denture base resins

Cardoso, Leandro 13 August 2018 (has links)
Orientador: Rafael Leonardo Xediek Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T01:07:44Z (GMT). No. of bitstreams: 1 Cardoso_Leandro_M.pdf: 718836 bytes, checksum: 03cc173acd1c7745a9df4dd35a8a70dc (MD5) Previous issue date: 2009 / Resumo: O objetivo deste trabalho foi verificar a resistência ao impacto da união denteresina acrílica, sob efeito da desinfecção simulada por energia de microondas. Cento e sessenta matrizes retangulares de cera utilidade (30x15x5mm) foram incluídas na parte inferior de muflas, com gesso pedra tipo III. Depois da cristalização do gesso, a cera foi removida e cada um dos 160 moldes de gesso resultante foi preenchido com silicone laboratorial. Sobre o silicone foi adaptado um dente molar de resina acrílica contendo um cilindro de cera (25mm de comprimento por 6mm de diâmetro) fixado na base. O conjunto foi revestido com silicone, a mufla preenchida com gesso pedra tipo III e levada à prensa de bancada por 1 hora. Em seguida, a mufla foi aberta e os conjuntos dente-cilindros removidos dos moldes. Os dentes foram escovados com solução de água quente e detergente líquido e adaptados nos moldes, com as bases submetidas previamente aos seguintes tratamentos: 1- sem tratamento, 2- desgaste com broca, 3- retenção com broca e 4- condicionamento com monômero. Oitenta cilindros de resina unidos à base dos dentes foram confeccionados com resina acrílica Clássico, em ciclo de água à temperatura de 74ºC por 9 horas, em termopolimerizadora automática (Termotron) e outros 80 com resina para microondas Onda-Cryl, em forno doméstico com 900W de potência: fase 1- três minutos com 40% da potência; fase 2- quatro minutos com 0% da potência; e fase 3- três minutos com 90% da potência. Os corpos-de-prova foram desincluídos após esfriamento das muflas em bancada. Metade dos corpos-de-prova de cada resina foi submetido à desinfecção simulada por microondas, em forno doméstico a 650W por 3 minutos, imersos individualmente em 150mL de água. Os demais corpos-de-prova não foram desinfectados (controle). Após armazenagem em água à temperatura de 37ºC por 24 horas, os corpos-de-prova foram submetidos ao teste de resistência ao impacto da união dente-resina, numa máquina Otto Wolpert Werke (sistema Charpy) com 40 kpcm de impacto. Os resultados obtidos foram submetidos à análise de variância e ao teste de Tukey para comparação das médias, em nível de 5% de significância. Os diferentes tratamentos na base dos dentes promoveram diferentes efeitos sobre a resistência da união dente-resina, em ambas as condições de desinfeção por microondas / Abstract: The aim of this study was to evaluate the effect of microwave disinfection in bond strength of acrylic teeth and a denture base resin. A hundred sixty rectangular wax patterns (30x15x5mm) were embedded in flasks with type III dental stone. After cristalization, the resulting moulds were filled with laboratorial silicone (Zetalabor), in which a molar acrylic tooth was included (36 Biotone IPN Vita) using a cylindrical wax (6x25mm) to join to the tooth base. The set was invested using laboratorial silicone and type III dental stone. After 1 hour, the flask was opened, the cylindrical wax removed from the tooth. Teeth were adapted in the moulds with the ridge laps submitted previously to the following treatments: 1 - no treatment; 2 -bur abrasion; 3 - bur grooving, and 4 - etched by monomer. Eighty rods of the Clássico acrylic resin atached to the tooth ridge lap were polymerized in bath cycle at 74ºC for 9 hours and deflasked after flask cooling, and 80 of Onda-Cryl acrylic resin were polymerized in 900W-domestic microwave oven following manufacturer's instructions. Specimens were deflasked after bench cooling. Fourty specimens of each acrylic resin were submitted to microwave disinfection, in a domestic oven at 650W for 3 minutes, individually immersed in 150mL of water. Other specimens were not disinfected (control). Specimens were stored in water at 37oC for 24 hours before impact test. Charpy impact strength test was performed using an impact testing machine (Otto Wolpert Werke) calibrated to 40 kpcm. Data were submitted to analysis of variance and Tukey's test at 5% of significance level. Different treatments on tooth ridge lap promoted different effects in the tooth-resin bond strength, in both conditions of simulated disinfection by microwave energy / Mestrado / Protese Dental / Mestre em Clínica Odontológica

Page generated in 0.0362 seconds