• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 210
  • 10
  • 10
  • 10
  • 10
  • 9
  • 7
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 220
  • 210
  • 117
  • 105
  • 89
  • 68
  • 45
  • 33
  • 28
  • 25
  • 24
  • 23
  • 23
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Estudio de pre-factibilidad para la implementación de una empresa fabricante de productos para baño a base de planchas acrílicas

Uría Carrera, José Daniel 09 May 2011 (has links)
Actualmente en el mercado se ofrecen productos sanitarios nacionales e importados, de material distinto al que todos conocemos (porcelana vitrificada). Entre los nacionales se identificó a una sola empresa localizada en Lima, que se dedica a producir esta clase de productos a base de plancha acrílica, la cual vio crecer su volumen de producción en mas de 133 en solo 5 años, indicando la preferencia creciente por este tipo de productos. Por otro lado, encontramos productos importados del mismo material, pero con menor acogida, debido a que estos tienen un precio de venta 45 más elevado que los nacionales. Por último, tenemos a los productos elaborados de plástico reforzado con fibra de vidrio, elaborados por una única empresa establecida también en Lima, cuyo volumen de producción ha tenido una tendencia creciente en los últimos años, pasando de producir 700 unidades el año 2004 a más de 1,000 unidades el año 2006. Todos estos productos difieren en precio, calidad y propiedades particulares que cada uno ofrece. Sin embargo, a pesar de toda la oferta existente, se identificó una demanda insatisfecha, pues se percibe una clara tendencia de la gente por adquirir productos innovadores, con nuevas formas y diseños, permitiendo tener un panorama prometedor para este tipo de productos alternativos para baños. Presentado el contexto actual, se concibe el proyecto de instalación de una planta de productos sanitarios elaborados a base de plancha acrílica, siendo una alternativa que ofrece productos de calidad y elaborados en base a las exigencias de las tendencias actuales, según los niveles socioeconómicos seleccionados, convirtiéndose en viable este proyecto, que se demuestra en el desarrollo de la presente tesis. / Tesis
122

Síntese, caracterização e efeito microbiológico de nanopartículas de sílica revestidas por prata quando associadas a resina acrílica quimicamente ativada, reembasador macio e ao glaze /

Lucatto, Bruna Corrêa. January 2017 (has links)
Orientador: Tarcisio José de Arruda Paes Junior / Coorientador: Fernando Cristovan / Banca: Lafayette Nogueira Júnior / Banca: João Paulo Barros Machado / Resumo: O objetivo deste trabalho foi sintetizar e caracterizar nanopartículas de sílica recobertas por prata, e avaliar a influência quando incorporadas à resina acrílica quimicamente ativada, ao reembasador macio, e a um glaze, em suas características microbiológicas, microestruturais e mecânicas. Foi confeccionada, pelo método de hidrólise e condensação controlada (método de Stober), uma solução contendo nanopartículas de sílica revestidas por nanopartículas de prata em duas proporções, 10 milimols e 30 milimols, onde as mesmas foram caracterizadas. As nanopartículas de sílica incorporadas com a prata foram analisadas por energia dispersiva de raios-X integrado (EDS), microscopia eletrônica de varredura (MEV), e espalhamento de luz dinâmico (DLS). Para análise microbiológica foram confeccionadas 10 amostras cilíndricas (2mmx10mm), em resina acrílica quimicamente ativada onde as partículas foram incorporadas em duas concentrações: 2.5% e 5% com as duas molaridades diferentes 10 mM e 30 mM. Em outra situação foram confeccionadas 10 amostras cilíndricas (2mmx10mm) de reembasador macio, com concentrações de 2,5% e 5% com as duas molaridades diferentes 10 mM e 30 mM, no terceiro caso as partículas foram acrescentadas a um glaze nas duas concentrações e molaridades e aplicada sob uma amostra de reembasador macio. Uma suspensão de Candida albicans e Estreptococos mutans foi utilizada para análise de concentração inibitória mínima. Amostras retangulares em resina acrílica (n=6) de 30x10x3... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this work was to synthesize and characterize silver - coated silica nanoparticles, and to evaluate the influence when incorporated into chemically activated acrylic resin, soft reliner, and glaze, in their microbiological, microstructural and mechanical characteristics. A solution containing silica nanoparticles coated by silver nanoparticles in two proportions, 10 millimols and 30 millimols, where they were characterized, was prepared by the hydrolysis and controlled condensation method (Stober method). Silica nanoparticles incorporated with silver were analyzed by integrated X-ray dispersive energy (EDS), scanning electron microscopy (SEM), and dynamic light scattering (DLS).For the microbiological analysis, 10 cylindrical samples (2mmx10mm) were made in chemically activated acrylic resin where the particles were incorporated in two concentrations: 2.5% and 5% with two different molarities of 10 mM and 30 mM. In another situation, 10 cylindrical samples (2mmx10mm) of soft reliner were made, with concentrations of 2.5% and 5% with the two different molarities 10 mM and 30 mM, in the third case the particles were added to a glaze in the two concentrations and molarities and applied under a sample of soft reliner. A suspension of Candida albicans and Streptococcus mutans was used for analysis of minimal inhibitory concentration. The samples were made in acrylic resin (n = 6) of 30x10x3mm and were made to perform the three-point flexural strength test of EMIC (Model ... (Complete abstract click electronic access below) / Mestre
123

Efeito da imersão em soluções desinfetantes na capacidade de formação de biofilme de C.albicans e características topográficas de uma resina acrílica para base de prótese e um reembasador /

Amaya Arbeláez, Maria Isabel January 2016 (has links)
Orientador: Janaina Habib Jorge / Resumo: O presente estudo teve como objetivo avaliar a capacidade de formação de biofilme de Candida albicans sobre resinas acrílicas para base (Vipi Wave) e reembasamento (Tokuyama Rebase Fast II) de próteses, após imersão diária por períodos de até 6 meses em soluções desinfetantes. Foram confeccionados 360 corpos de prova circulares de cada resina acrílica usando uma matriz metálica (14 x 1,2 mm). As amostras foram imersas overnight durante 0, 1, 3, e 6 meses em 5 soluções desinfetantes: hipoclorito de sódio 0,5%, perborato de sódio 3,8%, digluconato de clorexidina 2%, vinagre de maçã puro (Minhoto®) e água destilada (grupo controle). Após os diferentes períodos de imersão, um biofilme maduro de 48h de C. albicans (cepa ATCC 90028) foi formado sobre os corpos de prova. A capacidade de formação deste biofilme foi analisada utilizando o método de contagem de colônias (UFC/mL) e o ensaio de viabilidade celular Alamar Blue®. Para todos os grupos experimentais, imagens foram obtidas a partir de microscopia eletrônica de varredura (MEV) para avaliação das características topográficas das resinas após a imersão nos diferentes tempos. Todas os experimentos foram realizados em três ocasiões independentes. Análise de variância de três fatores (ANOVA) foi utilizada para avaliar o metabolismo celular (ensaio Alamar Blue®) e os valores de UFC/mL obtidos a partir da formação do biofilme de C. albicans. Foi adotado o nível de significância de 5%. Os resultados de Alamar Blue® mostraram um efeito... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
124

Efeito do material de recobrimento na deformação sofrida por infra-estruturas de próteses fixas implanto-suportadas, utilizando extensômetros lineares elétricos

Grando, Antônio Francisco 31 March 2003 (has links)
O sucesso dos implantes osseointegrados tem a influência decisiva dos aspectos biomecânicos, os quais interagem implantes, tecido ósseo e as próteses. O equilíbrio das forças que atuam sobre este complexo, remete-nos às diversas técnicas e materiais utilizados para a confecção das próteses fixas implanto-suportadas. O desenvolvimento de técnicas e materiais, bem como os desenhos das próteses vem trazendo um novo alento nas pesquisas. Este trabalho teve como objetivo averiguar a influência dos materiais de recobrimento estético, utilizados na confecção de próteses fixas implanto-suportadas, com relação à deformação destas próteses. Esta análise foi feita utilizando-se extensômetros lineares elétricos, analisando dois materiais de recobrimento. Um corpo de prova simulando uma prótese fixa de arco total, fundida em liga de paládioprata e recoberta em uma de suas metades por porcelana e na outra, por resina acrílica termopolimerizável. O corpo de prova foi fixado a um modelo-mestre e, após, aplicada uma carga estática vertical de 35,2 N, na extremidade livre, a uma distância de 10, 15 e 20 mm para distal do centro do implante terminal. Os resultados demonstraram que a aplicação de materiais de recobrimento estético, sobre uma infraestrutura metálica, tornam a mesma mais rígida e conseqüentemente com menor deformação. Outro fator confirmado nesta pesquisa foi a influência direta da extensão da extremidade livre que, nos pontos mais distantes de aplicação da carga, proporcionou maiores deformações. A pesquisa demonstrou que a porcelana proporciona menores índices de deformação da infra-estrutura metálica a ela associada, porém, fatores clínicos como qualidade e quantidade óssea, número e disposição dos implantes é que definem a escolha do material de recobrimento mais apropriado para cada situação. / The success of osseointegrated implants has a decisive influence of biomechanical aspects in wich implants, bone tissue and prosthesis are involved. The balance between the forces acting on this complex refer us to the diversity of methods and materials used to fabricate implant supported prosthesis. The aim of this study was to verify the influence of aesthetic covering materials on the deformation of cantilevered frameworks. Strain gauges were bonded to the inferior surface of a silver-palladium framework covered with ceramic and thermoacrylic resin on each of its two halves. The framework was fixed to a metallic master model and a 35.2N vertical static load was apllied to the free end at the distances of 10, 15 and 20mm distal to the terminal abutment. The results showed that the use of a rigid material such as ceramic stiffen even more the framework, with consequently less deformation. Another finding that was confirmed in this study was the direct influence of cantilever length on deformation of implant supported frameworks.
125

Soluções higienizadoras de prótese total: avaliação da remoção de biofilme e efeito sobre propriedades da resina acrílica termopolimerizável / Denture cleansing solutions: evaluation of the biofilm removal and effect on properties of heat-polymerized acrylic resin

Peracini, Amanda 31 May 2012 (has links)
Este estudo avaliou o efeito de soluções higienizadoras de próteses totais quanto ao controle do biofilme (análise clínica) e à alteração de propriedades da resina acrílica (análise laboratorial). A análise clínica foi realizada em 32 desdentados totais que foram orientados a escovar suas próteses (escova Denture e sabonete líquido) três vezes ao dia e imergí-las (″overnight″) nas soluções: 1) Controle: Água Natural; 2) Pastilha Corega Tabs; 3) Hipoclorito de Sódio 0,5%. Cada solução foi utilizada por 21 dias (03 ciclos de 07 dias). Ao final de cada ciclo, a superfície interna da prótese superior foi evidenciada (vermelho neutro 1%) e fotografada (HX1- Sony). As áreas (total e corada com biofilme) foram medidas (Image Tool 3.00), sendo a porcentagem de biofilme calculada como a relação entre a área do biofilme multiplicado por 100 e área da superfície total da base interna da prótese. Para a análise laboratorial, foram confeccionados 140 corpos de prova de resina acrílica termopolimerizável (Lucitone 550) que foram imersos por 08 horas nas soluções: 1) Controle 1 (sem imersão); 2) Controle 2 (água destilada); 2) Pastilha Corega Tabs; 3) Hipoclorito de sódio 0,5%, simulando uma higienização diária de 03 anos (1095 dias). Antes e após as imersões, os corpos de prova foram avaliados quanto à alteração de cor (Espectrocolorímetro Color Guide 45/0), rugosidade superficial (rugosímetro Surftest SJ-201P) e resistência à flexão (Máquina Universal de Ensaios DL 2000). Os dados de cor foram também calculados de acordo com a National Bureau of Standards (NBS). As análises estatísticas compreenderam o método de equações de estimação generalizadas (GEE) e comparações múltiplas (Teste de Bonferroni - α = 1,67%) para análise clínica; e Análise de Variância (ANOVA) e teste HSD de Tukey (α=0,05) para análise laboratorial. Os resultados clínicos mostraram que a imersão em hipoclorito de sódio 0,5% diminuiu a área coberta por biofilme (8,29 ± 13,26 - B), quando comparado ao controle (18,24 ± 14,91 - A) e à pastilha (18,18 ± 16,62 - A). O hipoclorito (2,75 ± 0,49 - B) e a pastilha (3,01 ± 0,35 - B) provocaram alteração de cor significativamente maior que o controle (0,66 ± 0,29 A), sendo classificadas como perceptível, segundo a NBS. As soluções não alteraram a rugosidade da resina. Houve uma diminuição na resistência à flexão dos grupos pastilha (85,61 ± 10,46 - C) e hipoclorito (82,17 ± 8,47 - C) quando comparados com o controle (sem imersão) (105,4 ± 14,93 - A). O controle (água destilada) apresentou uma redução na resistência à flexão (67,06 ± 11,89 - B). Os achados deste estudo revelaram que a solução de hipoclorito de sódio 0,5% foi a mais efetiva na remoção do biofilme das próteses totais e que ambas as soluções (hipoclorito de sódio 0,5% e peróxido alcalino) não alteraram a rugosidade superficial, porém provocaram alterações de cor classificadas como perceptíveis segundo a NBS, bem como acarretaram uma diminuição da resistência à flexão da resina acrílica termicamente ativada. / This study evaluated the effect of denture cleansers on denture biofilm removal (clinical trial) and changes the properties of acrylic resin (laboratory analysis). A randomized clinical trial was performed in 32 edentulous patients who were instructed to brush their dentures (denture-specific brush and liquid soap) three times a day and to soak them overnight in the solutions: 1) Control: Water; 2) Efervescent Tablet (Corega Tabs); 3) 0.5% Sodium Hypochlorite. Each solution was used for 21 days (03 alternate cycles of 07 days). At the end of each cycle, the inner surfaces of maxillary dentures were disclosed (1% neutral red) and photographed (HX1 Sony). Total and stained biofilm areas were measured (Image Tool 3.00), and the percentage of biofilm calculated as the ratio between the area of the biofilm multiplied by 100 and total surface area of the internal base of the denture. For laboratory analysis, 140 specimens were prepared from heat-polymerized acrylic resin (Lucitone 550) and immersed for 08 hours in the solutions: 1) Control 1 (without immersion); 2) Control 2 (distilled water); 3) Efervescent Tablet Corega Tabs; 4) 0.5% Sodium Hypochlorite, simulating a daily hygiene of 03 years (1095 days). Before and after immersion, specimens were evaluated for color change (portable colorimeter Color Guide 450), surface roughness (Surface Roughness Tester SJ-201P) and flexural strength (universal testing machine DL 2000). Color data were also calculated according the National Bureau of Standards (NBS). Statistical analysis comprised the method of generalized estimating equations (GEE) and multiple comparisons (Bonferroni - α = 1.67%) for clinical analysis, and analysis of variance (ANOVA) and Tukey′s HSD test (α=0.05) for laboratory analysis. Clinical results showed that the immersion in sodium hypochlorite 0.5% reduced the area covered by biofilm (8.3 ± 13.3 - B) compared to the control (18.2 ± 14.9 - A) and tablet (18.2 ± 16.6 - A). Hypochlorite (2.8 ± 0.5 - B) and tablet (3.0 ± 0.4 - B) caused significantly higher color change than the control (0.7 ± 0.3 A); such changes were classified as noticeable, according to NBS. The solutions did not alter the roughness of the resin. There was a decrease in the flexural strength of the groups tablet (85.6 ± 10.5 - C) and hypochlorite (82.2 ± 8.5 - C) compared to control (without immersion) (105.4 ± 14.9 - A). The control (distilled water) showed a reduction in flexural strength (67.1 ± 11.9 - B). The findings revealed that the 0.5% sodium hypochlorite solution was the most effective for biofilm removal from complete dentures and that both solutions (0.5% sodium hypochlorite and alkaline peroxide) did not alter surface roughness, but caused color changes classified as noticeable according to the NBS, and resulted in a decrease of flexural strength of heat-polymerized acrylic resin.
126

Efeito antagonista de probióticos isolados e comerciais sobre o crescimento de Candida albicans em superfície de resina acrílica para próteses dentárias /

Catanoze, Isabela Araguê. January 2018 (has links)
Orientador: Aimée Maria Guiotti / Coorientadora: Cristiane Duque / Banca: Douglas Roberto Monteiro / Banca: Natália Leal Vizoto / Resumo: A estomatite protética é associada à colonização microbiana da base acrílica das próteses, favorecida pela higiene deficiente das mesmas e pelo alto nível de Candida spp. na cavidade oral. A Candida albicans é a espécie fúngica mais comumente associada à esta patologia oral, geralmente tratada com antifúngicos. O uso indiscriminado destas drogas pode promover resistência destas espécies e efeitos colaterais aos indivíduos. Assim, é desejável promover a saúde por meio de terapias naturais ou alternativas, tais como a utilização de microrganismos probióticos. O objetivo desta pesquisa foi avaliar in vitro, a influência de diferentes probióticos isolados e dois probióticos comerciais na inibição do crescimento do biofilme de C. albicans em resina acrílica ativada termicamente (RAAT) para base protética e verificar se os subprodutos dos biofilmes teriam um potencial de alteração da superfície das amostras de RAAT (Ra). 90 amostras de RAAT foram divididas em 9 grupos: GI- controle negativo (Candida albicans sem probiótico); GII- Candida albicans + Lactobacillus casei; GIII- Candida albicans + Lactobacillus rhamnosus; GIV- Candida albicans + Lactobacillus helveticus; GV- Candida albicans + Bifidobacterium lactis; GVI- Candida albicans + Bifidobacterium longum; GVII- Candida albicans + Lactobacillus fermentum; GVIII- Candida albicans + Microbiome e GIX- Candida albicans + Prolive. Biofilmes de C. albicans foram formados sobre as superfícies das amostras de RAAT na presença dos probi... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Prosthetic stomatitis is associated with microbial colonization of the prosthesis base, favored by poor hygiene of the species and the high level of Candida spp. in the oral cavity. Candida albicans is a fungal species most commonly associated with oral pathology, usually treated with antifungal. Indiscriminate use can cause damage to species and side effects to individuals. Thus, it is desirable to promote health through natural or alternative therapies, such as the use of probiotic microorganisms. The objective of this research was to evaluate in vitro, the influence of different probiotics and two commercial probiotics on the inhibition of C. albicans biofilm growth in thermally activated acrylic resin (RAAT) for prosthetic base and to verify if biofilm byproducts would have potential alteration of the surface of RAAT (Ra) samples. 90 RAAT samples were divided into 9 groups: GI- negative control (Candida albicans without probiotic); GII- Candida albicans + Lactobacillus casei; GIII- Candida albicans + Lactobacillus rhamnosus; GIV- Candida albicans + Lactobacillus helveticus; GV- Candida albicans + Bifidobacterium lactis; GVI- Candida albicans + Bifidobacterium longum; GVII- Candida albicans + Lactobacillus fermentum; GVIII- Candida albicans + Microbiome and GIX- Candida albicans + Prolive. Biofilms of C. albicans were formed on the surfaces of RAAT samples in the presence of probiotics, except for GI group. For biofilm quantification, the number of cultured cells in the RA... (Complete abstract click electronic access below) / Mestre
127

Efeito da interação entre bebidas coradas e métodos de limpeza na estabilidade da cor de resinas acrílicas / Effect of interaction between colored drinks and cleaning methods on color stability of acrylic resins

Rebello, Heverson Luiz da Costa 11 July 2014 (has links)
Submitted by Fabiano Malheiro (fabianomalheiro22@hotmail.com) on 2017-06-02T17:37:24Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Efeito da interação entre bebidas coradas e métodos de limpeza na estabilidade de cor de resinas acrílicas.pdf: 629918 bytes, checksum: beef289f14043aa98cd908ea8e2a0089 (MD5) / Made available in DSpace on 2017-06-02T17:37:24Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Efeito da interação entre bebidas coradas e métodos de limpeza na estabilidade de cor de resinas acrílicas.pdf: 629918 bytes, checksum: beef289f14043aa98cd908ea8e2a0089 (MD5) Previous issue date: 2014-07-11 / Sem bolsa / Este estudo procura compreender melhor a possível interação entre os agentes de limpeza para prótese dentária disponíveis no mercado e algumas bebidas coradas que podem interferir na cor das resinas acrílicas de bases protéticas, e determinar qual a melhor técnica de polimerização das resinas no que diz respeito à estabilidade de cor nessa possível interação utilizado 3 técnicas de termopolimerização (ciclo longo, ciclo curto e micro-ondas). Materiais e Métodos: 96 discos de resina acrílica foram processados com cada técnica e após o acabamento e polimento aleatoriamente divididos em 4 grupos (n=24) para imersão nas bebidas água, chá, café e vinho por 30 dias, tendo a sua cor inicial aferida nos eixos da escala CIE – L*a*b* com um colorímetro. Cada grupo foi novamente dividido em 3 subgrupos (n=8) para serem submetidos diariamente aos processos de limpeza (água, hipoclorito de sódio 5% e pastilha efervescente de perborato de sódio) por 5 minutos. A cor das resinas foi novamente aferida após o período de 30 dias. A análise estatística foi realizada utilizando o programa gratuito GMC e os dados foram analisados utilizando ANOVA e teste complementar de Tukey. Houveram diferenças em todas as variáveis testadas, sendo que a polimerização por microondas e o perborato apresentaram melhores desempenhos em preservar a coloração original das resinas. O hipoclorito também foi efetivo em diminuir a pigmentação dos corpos de resina. Concluiu-se que a utilização de qualquer um dos agentes de limpeza utilizados neste estudo é efetivo na manutenção da cor das resinas acrílicas de bases protéticas. / This study seeks to better understand the possible interaction between agents for cleaning dentures available in the market and some colored drinks that can interfere with the color of acrylic resin denture bases simulating its use, and determine the best technique polymerization of resins in respect to color stability 3 used in this possible interaction techniques thermal polymerization (long cycle , short cycle and microwave). 96 discs of acrylic resin were processed with each technique and randomly divided into 4 groups (n=24) according to the staining beverages (water, tea, coffee and wine). After finishing and polishing, its color was measured on the axis of scale CIE - L * a * b * with a colorimeter and immersed in beverages. Daily each group was further divided into three subgroups (n=8) to be subjected to cleaning processes (water, 5% sodium hypochlorite tablet, effervescent perborate) for 5 minutes. The color of the resins was measured again after 30 days. Statistical analysis was performed using the free program GMC, chi -square analysis of adherence to the normal curve and the data were analyzed using ANOVA. There were differences between the various polymerization techniques with Tukey test (p <0.05) and there were interactions between the beverage and stained cleaning agents. It was concluded that the use of one of the cleaning agents used in this study is effective in maintaining color of acrylic resin denture bases.
128

Obtenção de nanocompósitos de resinas acrílicas dentárias com partículas de alumina dopada com manganês / Obtaining nanocomposite dental acrylic resins with particles of alumina doped with manganese

Cruzeiro, Mario Thadeo Rodrigues 23 September 2014 (has links)
Submitted by Fabiano Malheiro (fabianomalheiro22@hotmail.com) on 2017-06-09T15:18:33Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Obtenção de nanocompósitos de resinas acrílicas dentárias com partículas de alumina dopada com manganês.pdf: 828927 bytes, checksum: 042b9bc4f5329424faab8121e985d13a (MD5) / Made available in DSpace on 2017-06-09T15:18:33Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Obtenção de nanocompósitos de resinas acrílicas dentárias com partículas de alumina dopada com manganês.pdf: 828927 bytes, checksum: 042b9bc4f5329424faab8121e985d13a (MD5) Previous issue date: 2014-09-23 / Sem bolsa / Pigmentos de Al2O3:Mn foram utilizados de forma inovadora no presente trabalho para melhorar as características estéticas de resinas acrílicas para base de prótese. O objetivo deste estudo foi investigar a síntese e o efeito da pigmentação de nanopartículas de Al2O3:Mn na estabilidade de cor de resinas acrílicas. As resinas acrílicas comerciais Clássico Jet X15 rosa e Clássico Jet X15 incolor foram avaliadas. Nanopós de Al2O3:Mn foram preparados pelo método de precursores poliméricos, para estudar a relação entre a transição de fase. A morfologia dos pigmentos foi analisada por meio de um microscópio eletrônico de varredura (MEV) e a energia dispersiva por técnicas de espectroscopia de raios-X (EDX). Espécimes em forma de prisma (65mm × 10mm × 2,5mm) de resina acrílica incolor cor rosa e de resina acrílica incolor modificada com 1% e 2% de pigmento sintetizado à base de Al1,96Mn0,04O3 foram fabricados. A cor dos espécimes foi medida com um espectrofotômetro e avaliadas dentro do sistema CIE L*a*b*. A resistência à flexão e o módulo de elasticidade dos materiais foram avaliados em ensaio de flexão por três pontos. Os pigmentos obtidos apresentaram colorações diferenciadas em relação à antes e após a aplicação, devido à interação das partículas do pigmento com o material da resina. Notou-se que pigmentos de nanopartículas contendo manganês apresentaram coloração rosa mais compatível com resinas coloridas comerciais. Os conteúdos de cátions cromóforos (responsáveis pela coloração) do Al2O3, de acordo com a metodologia proposta neste trabalho, são mínimos e puderam ser controlados. Por meio de ensaios de flexão, notou-se um efeito positivo em relação ao aumento da resistência mecânica, em função da adição do pigmento sintetizado. Conclui-se que os pigmentos sintetizados têm duas vantagens em relação às resinas acrílicas coloridas comerciais: a possibilidade de controle efetivo de cor e o aumento de resistência mecânica. / Al2O3:Mn pigments were used in an innovative way in this work to improve the aesthetic characteristics of acrylic resin for denture base. The aim of this study was to investigate the synthesis and the effect of pigmentation of nanoparticles of Al2O3:Mn on the color stability of acrylic resins. Commercial acrylic resins Classic Jet X15 pink and colorless Classic Jet X15 were evaluated. Nanopowders of Al2O3:Mn were prepared through the polymeric precursors method, in order to study the relationship between phase transition. The morphology of the pigments was analyzed by a scanning electron microscope (SEM) and x-ray energy dispersive spectroscopy (EDX). Prism-shaped specimens (65mm × 10mm × 2.5mm) of pink-colored acrylic resin and of colorless acrylic resin with 1% or 2% of the synthesized Al1.96Mn0.04O3 pigment were prepared. The color of the specimens was measured with a spectrophotometer and evaluated in the CIE L*a*b* system. The flexural strength and elastic modulus of the materials were measured on three-point bending mode. The pigments obtained showed different color compared to before the application, due to the interaction of the pigment particles with the resin material. It was noted that pigments containing manganese nanoparticles exhibit a pink coloration which is more compatible to commercial resins. The content of Al2O3 chromophore cations (responsible for the color), according to the methodology proposed in this work, is minimal and could be controlled. By using the flexural test a positive effect was noticed as regards the increase in mechanical strength as a function of pigment addition. In conclusion, the synthesized pigments have two advantages in comparion with the commercial colored acrylic resins: the possibility of effective color control and the increase in mechanical strength.
129

Efeito do armazenamento prolongado em água sobre a resistência de união entre resinas para reembasamento e resina para base de prótese /

Azevedo, Andréa. January 2005 (has links)
Orientador: Ana Lucia Machado / Banca: Eunice Teresinha Giampaolo / Banca: Cláudio Rodrigues Leles / Resumo: Este estudo avaliou o efeito da armazenagem prolongada em água sobre a resistência de união entre uma resina acrílica para base de prótese (Lucitone 550) e quatro resinas para reembasamento (Kooliner - K, New Truliner - NT, Tokuso Rebase - TR e Ufi Gel Hard - UGH). Além disso, a resistência de união ao cisalhamento de corpos-de-prova reembasados com a resina acrílica para base de prótese L foi avaliada para comparação. Cilindros (20 mm X 20 mm) de resina acrílica L foram polimerizados (em água a 70°C por 90 minutos, e por 30 minutos à temperatura de ebulição) de acordo com instruções do fabricante e imersos em água destilada (37 l 1°C por 48 l 2 horas). As superfícies de união foram polidas com lixa de granulação 240, escovadas com detergente (20 segundos), limpas com água destilada e secas com papel absorvente. As superfícies foram, então, preparadas por meio da aplicação do monômero da resina L (180 segundos) para a resina K e com os agentes de união (20 segundos) para as demais resinas. Uma fita adesiva com orifício (3,5 mm) foi fixada sobre a superfície tratada para padronizar a área de união. Cada cilindro foi acoplado a uma matriz metálica bipartida com um orifício central (3,5 mm X 5,0 mm). Os materiais para reembasamento foram manipulados, inseridos na matriz e polimerizados de acordo com as instruções dos fabricantes. Após a polimerização, os corpos-de-prova de cada material reembasador foram divididos em cinco grupos (n=8) e submetidos aos testes de cisalhamento (velocidade = 0,5 mm/min). Para o grupo controle (G1), os testes foram realizados imediatamente após a polimerização, para as resinas de reembasamento, e após os corpos-de-prova terem sido imersos em água (37 l 1° C) por 48 l 2 horas para a resina de base L. Os corpos-de-prova relativos aos Grupos 2, 3 e 4 foram testados após terem sido armazenados em água (37 l 1° C)...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of long-term water storage on the shear bond strength between one heat-polymerizing denture base acrylic resin (Lucitone 550-L) and four autopolymerizing reline resins (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Also, the shear bond strength of specimens relined with the denture base resin L was evaluated, for comparison. Cylinders (20mm x 20mm) of the resin L were processed (in water at 70°C for 90 minutes, and 30 minutes at boiling temperature), according to the manufacturer's instructions, and stored in distilled water (37 l 1° C for 48 l 2 hours). The surfaces to be bonded were ground with 240-grit silicon carbide paper, brushed with detergent (20 s), washed in distilled water, and blot-dried. The bonding sites were prepared by painting the surfaces with L monomer (180 seconds) for resin K, and with the bonding agents (30 seconds) for the other resins. A tape with a circular opening (3.5 mm) was placed on the treated surfaces to provide a uniform bonding area. Each cylinder was placed in a stainless steel split mold with a center hole (3.5x5.0 mm). The reline materials were mixed, applied to the mold, and polymerized according to the manufacturers' instructions. After polymerization, specimens of each reline material were divided into 5 groups (n=8), and submitted to shear tests (at a 0.5 mm/min cross-head speed). For control group (G1), the tests were performed immediately after processing for the reline resins, and after the specimens had been stored in water (37 l 1° C) for 48 l 2 hours for the denture base resin L. Groups G2, G3 and G4 specimens were tested after being stored in water (37 l 1° C) for 7 days, 3 months, and 6 months, respectively. The fractured surfaces were examined using scanning electron microscope and an image analysis system to determine the percentage surface area that remained...(Complete abstract click elctronic access below) / Mestre
130

Efeito de desinfecções sucessivas com energia de microondas na resistência de união entre dentes artificiais e resinas para bases de próteses /

Chuqui, Roberta. January 2005 (has links)
Orientador: Eunice Teresinha Giampaolo / Banca: Ana Lucia Machado / Banca: Hércules Jorge Almilhatti / Resumo: Este estudo avaliou o efeito de desinfecções sucessivas por meio da utilização de microondas sobre a resistência de união entre dentes artificiais (incisivos centrais superiores: Biotone - DB, modelo 264 e Vivodent - DV, modelo A15) e resinas para bases (QC20 - QC, Acron MC - AC e Lucitone 550 - L). Os dentes artificiais foram posicionados em anéis de PVC (20 mm de diâmetro e 20 mm de altura) preenchidos com cera. Cada anel foi incluído em silicone por condensação para facilitar posteriormente a remoção das amostras polimerizadas. Esses moldes de silicone foram então incluídos em mufla dental com gesso. A cera foi eliminada com água em ebulição, sendo o molde preenchido com resina acrílica, manipulada e polimerizada de acordo com as instruções do fabricante. Quarenta corpos-de-prova foram obtidos para as três resinas de base com as duas marcas de dentes avaliados. Todas as amostras foram divididas aleatoriamente em quatro grupos. G1 (controle) - amostras imersas em água destilada a 37ºC por 48 horas; G2 - imersas por 48 horas e submetidas a dois ciclos de desinfecção por 6 minutos a 650 W; G3 - imersas por 48 horas em água destilada e submetidas a sete ciclos de desinfecção (um por dia) por 6 minutos a 650 W, estando as amostras imersas em água a 37ºC entre as desinfecções; G4 - imersas em água destilada por 8 dias (controle). O teste de cisalhamento foi realizado em máquina de ensaios MTS - 810 com a força aplicada na superfície palatina dos dentes em ângulo de 45º e velocidade de 0,5 mm/min. As superfícies de fratura foram observadas em lupa esteroscópica com um aumento de 10 vezes para determinar a natureza da falha (adesiva, coesiva ou mista). Adicionalmente, foi realizada microscopia eletrônica de varredura. Os dados (MPa) foram analisados utilizando ANOVA, teste de Tukey e teste t de Student (P=0,05)...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of microwave disinfection on the bond strength of denture teeth (maxillary central incisors: Biotone - DB, model 264 and Vivodent - DV, model A15) to acrylic resins (QC20 - QC, Acron MC - AC and Lucitone 550 - L). Denture teeth were positioned within polyvinylchloride tubes (20 mm diameter and 20 mm length) filled with melted wax. The tubes were invested in silicone rubber to facilitate removal of the processed specimens from the flask. These silicone moulds were then invested in the usual denture flasks in dental stone. The wax was boiled out, the mould was packed with denture resin and polymerized according to the manufacturer's instructions. Forty specimens were formed from each of the three denture base resin with the two brands of denture teeth. All specimens were randomly divided into four groups to provide a sample size of 10. G1 (control group) - immersed in distilled water at 37ºC for 48 hours; G2 - immersed in distilled water at 37ºC for 48 hours and microwaved twice at 650W for 6 minutes; G3 - immersed in distilled water at 37ºC for 48 hours and microwaved (650 W for 6 minutes) daily for 7 days, being stored in water at 37ºC between exposures; G4 (control group) - immersed in distilled water at 37ºC for 8 days. Shear load was applied with a load testing machine at 45 degrees from the long axis of each denture tooth on the palatal surface at a crosshead speed of 0.5mm/min until fracture. Fracture surfaces were evaluated with an optical stereomicroscope under x 10 magnifications to determine the nature of the failure (adhesive, cohesive or combination). In addition, a representative sample of each experimental group was evaluated with a scanning Electron Microscopy (SEM). The data (MPa) were analyzed statistically using 3-way ANOVA, Tukey's test and Student's t test (P=0.05)...(Complete abstract, click electronic address below) / Mestre

Page generated in 0.0394 seconds