31 |
Determinação da carga crítica de instabilidade lateral no regime linear elástico, em vigas de madeira laminada colada (MLC) / Determination of critical load of lateral instability in the linear elastic regime, on glued laminated wood beamsCelso Antonio Abrantes 11 October 2012 (has links)
O crescente aumento do uso de madeira laminada colada (MLC) em peças estruturais exige dos meios acadêmicos a pesquisa e desenvolvimento de teorias e rotinas de cálculo, que proporcionem suporte teórico para projetos estruturais que empreguem tal material. Nesta pesquisa foi desenvolvido em laboratório de modelos estruturais, um programa para o cálculo estrutural de vigas de madeira laminada colada (MLC), por meio do método dos elementos finitos para material ortotrópico e material isotrópico. Foram rompidas, em uma prensa universal, vigas de Madeira Laminada Colada (MLC), em escala natural, com e sem emendas nas lâminas, com a finalidade de comparação dos resultados assim obtidos, com os obtidos em modelos de cálculo existentes para vigas maciças de material isotrópico, como o método de cálculo da NBR 7190/97 e o método de cálculo da Teoria da Elasticidade (Timoshenko). Tais resultados também foram comparados com os resultados obtidos pelo método dos Elementos Finitos para materiais isotrópicos e ortotrópicos, acima citados. Para comparação entre as propriedades da madeira maciça e da madeira laminada colada, foram retirados corpos de prova das partes intactas das vigas sacrificadas, para realização de ensaios de cisalhamento na linha de cola e nas lâminas coladas, bem como corpos de prova para ensaios de flexão nas lâminas maciças das vigas de MLC. Para obtenção da tensão de ruptura a compressão paralela às fibras e do módulo de elasticidade, foram rompidos corpos de prova de 5cm x 5 cm x 15 cm. A comparação e análise dos resultados obtidos pelos procedimentos acima, levou à conclusão de que a madeira laminada colada (MLC), quando fabricada com cola estrutural, comporta-se como madeira maciça. Também foi possível observar que os modelos de cálculo empregando elementos finitos, ortotrópicos ou isotrópicos, reproduzem o comportamento de uma viga de madeira laminada colada. O modelo de cálculo da NBR 7190/97, pode ser empregado, mas apresenta resultados conservadores, a favor da segurança. Assim como o modelo de cálculo da Teoria da Elasticidade não deve ser empregado sem adaptação à madeira, pois apresentou resultados muito discrepantes. Os módulos de elasticidade da madeira maciça obtidos por ensaios de flexão e a partir do ensaio de compressão paralela às fibra, não representa o módulo de elasticidade representativo de uma viga de MLC. Da mesma forma a existência ou não de emendas nas lâminas, não altera os resultados. / The increasing use of glued laminated timber in structural parts requires academic research and development of theories and calculation routines that provide theoretical support for structural designs employing such material. In this research was developed in the laboratory of structural models, a program for calculating structural glued laminated timber beams by the finite element method for orthotropic material and isotropic material. Were disrupted in a press universal beam of glued laminated wood in full scale with and without splices blades, for the purpose of comparison of the results thus obtained with those obtained in calculation models exist for solid beams material isotropic, as the method of calculating the NBR 7190/97 and the calculation method of the theory of elasticity (Timoshenko). These results were also compared with results obtained by the method of finite elements for isotropic and orthotropic materials, mentioned above. To compare the properties of solid wood and glued laminated timber, specimens were removed from intact parts of the broken beams for testing shear line glue and glued the layers, as well as specimens for bending tests blades massive beam. To obtain the tensile strength parallel to the compression of the fibers and elastic modulus were broken specimens with the dimensions 5 cm x 5 cm x 15 cm. The comparison and analysis of the results obtained by the above procedure led to the conclusion that the glued laminated wood when manufactured with structural adhesive, behaves as solid wood. It was also noted that the model calculations using finite elements, both isotropic and orthotropic represent the behavior of a beam of glued laminated wood. The calculation model of the NBR 7190/97, can be employed, but has conservative results, in favor of security. As the calculation model of the theory of elasticity should not be used without adjustment to the wood, because it showed very discrepant results. The modulus of elasticity of solid wood obtained by bending tests from test and compression parallel to the fiber, it is not the representative elastic modulus of a beam of glued laminated wood. Likewise, the presence or absence of amendments in the layers, does not change the results.
|
32 |
Avaliação da associação de clorexidina com etanol na durabilidade da adesão à dentina / Evaluation of the adjunctive use of chlorhexidine and ethanol on the durability of resin dentin bondsAdriana Pigozzo Manso 05 November 2009 (has links)
A degradação do adesivo e colágeno é considerada uma das principais causas de falhas nos processos adesivos à dentina. A completa infiltração de resinas hidrofóbas facilitada pelo etanol, associada à presença de inibidores de metaloproteinases presentes na dentina, poderia construir a união ideal, resistente à hidrólise e atividades enzimáticas. Este estudo examinou os benefícios do uso combinado de clorexidina como inibidor de metaloproteinases e etanol, na durabilidade de uniões resina-dentina. Foram utilizados 48 terceiros molares hígidos para obter superfícies planas de dentina que foram condicionadas com ácido fosfórico a 32% por 15 segundos, lavadas por 30 segundos, e secas com papel absorvente. Imediatamente após, uma das seguintes soluções foi aplicada por 30 segundos: água (A); etanol (E); solução aquosa de clorexidina a 1% (CA); solução alcoólica de clorexidina a 1% (CE). O excesso foi removido com papel absorvente e um dos adesivos, All Bond 3 (AB3) ou Excite (EX), foi aplicado à superfície sob agitação por 15 segundos, seguido por um jato de ar por igual tempo, e fotoativado por 20 segundos. Uma coroa de aproximadamente 4 mm foi construída incrementalmente em resina composta e os dentes foram armazenados por 24 horas em água destilada à 370C. A seguir foram cortados em paralelogramos para o teste de microtração. Um terço dos corpos de prova foi ensaiado imediatamente e os demais permaneceram armazenados por 6 ou 15 meses. Os efeitos dos tratamentos e períodos de armazenagem foram analisados para cada adesivo. Os resultados não demonstraram interação entre os fatores para ambos os adesivos. AB3 foi significantemente afetado pela armazenagem, mas não pelos tratamentos. EX foi significantemente afetado pelo tratamento, mas não pela armazenagem. Concluiu-se que o uso de clorexidina/etanol não melhorou a estabilidade da união após 15 meses. AB3 quando tratado com A ou CA, e EX com todos os tratamentos não foram afetados pela armazenagem. / Both adhesive and collagen degradation have been regarded as major causes of resin-dentin bonds failures over time. Complete infiltration of hydrophobic resins facilitated by ethanol, and the presence of MMPs inhibitors within the hybrid layer would build the ideal interface, resistant to hydrolysis and enzymatic activities. This study examined the benefits of the adjunctive use of chlorhexidine and ethanol on the durability of resin dentin bonds. Forty-eight flat dentin surfaces were etched (32% phosphoric acid), rinsed (30s) and blot-dried with absorbent paper. The surfaces were re-wetted with either water (Water); 1% chlorhexidine diacetate in water (CHX/Water); 100% ethanol (Ethanol); and 1% chlorhexidine diacetate in ethanol (CHX/Ethanol) solutions for 30s. They were then bonded with All Bond 3 (AB3, Bisco) or Excite (EX, Ivoclar- Vivadent) using a smooth, continuous rubbing application (15s), followed by 15s gentle air dry. The adhesives were light-cured (20s) and resin build-ups constructed incrementally for the microtensile method. Bonded beams were obtained and tested after 24-hours, 6-months, and 15- months water storage at 370C. Effects of treatment and testing periods were analyzed (ANOVA, Holm-Sidak, p<0.05) for each adhesive. There were no interactions between factors for both adhesives. AB3 was significantly affected by storage, but not by treatments. Excite was significantly affected by treatments, but not by storage. Adjunctive use of ethanol/chlorhexidine did not improve bond stability after 15 months. AB3 treated either with ethanol or CHX/ethanol resulted in reduced bond strengths after 15 months. AB3 treated with water or CHX/water and all treatments for Excite were not affected by storage.
|
33 |
Avaliação in vitro da ação anti-bacteriana de um adesivo auto-condicionante acrescido de clorexidina / In vitro evaluation of the antibacterial behavior of a self-etch adhesive incorporated with chlorhexidineRodrigues, Roberta Bento 13 December 2016 (has links)
Submitted by Neusa Fagundes (neusa.fagundes@unioeste.br) on 2018-07-12T19:16:44Z
No. of bitstreams: 2
Roberta_Rodrigues2016.pdf: 550322 bytes, checksum: 270469fe680e8ab3e1299ebd0c7bcd19 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-07-12T19:16:44Z (GMT). No. of bitstreams: 2
Roberta_Rodrigues2016.pdf: 550322 bytes, checksum: 270469fe680e8ab3e1299ebd0c7bcd19 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2016-12-13 / Adhesive technology has been developed quickly since its introduction about fifty years ago. Its goal is to produce a close contact within enamel and dentin. Failures in this process could result in microleakage, and allow the infiltration of bacteria, fluids and ions. Recent studies have been shown the use of chlorhexidine associated with adhesive systems can be able to inhibit the bacteria action. The aim of this study was to evaluate the addiction of different percentages of chlorhexidine to a self-etch adhesive. The solution of digluconate chlorhexidine was increased to the primer of the two pass self-etch adhesive to create a 0,5%, 1,0% and 2,0% chlorhexidine primer solution and after they were distributed in four groups (G1, G2, G3 and G4). Saliva samples (N=10) were used to test bacteria activity. They were spread in a blood medium with filter paper disks containing the different treatments. After the incubation, the inhibitions halos formation were evaluated. This study demonstrated that, in vitro, the addition of different percentages of chlorhexidine digluconate to the self-etch adhesive induced inhibited halos at bacteria of saliva samples, independent from their concentration. / A tecnologia adesiva vem se desenvolvendo rapidamente desde que foi introduzida há mais de 50 anos. Seu principal objetivo é alcançar um íntimo contato entre a estrutura dental e o material restaurador e fornecer adequada adesão entre o esmalte e a dentina. Falhas nesse processo adesivo podem resultar em microinfiltração marginal com passagem de bactérias, fluidos ou íons entre a parede cavitária e o material restaurador. Recentes estudos têm demonstrado que a utilização da clorexidina associada ao sistema adesivo pode ser capaz de inibir a ação das bactérias. O objetivo do presente estudo foi avaliar o efeito antibacteriano de um sistema adesivo auto-condicionante de dois passos associado a diferentes concentrações de solução de digluconato de clorexidina. A solução de digluconato de clorexidina a 20% foi adicionada ao primer do sistema adesivo nas concentrações de 0,5, 1,0 e 2,0% e distribuídas em quatro grupos (G1, G2, G3 e G4). Para o teste de atividade antibacteriana foram utilizadas amostras de saliva (N=10) semeadas em meio de ágar sangue e discos de papel filtro contendo os diferentes grupos. Após incubação, as amostras foram inspecionadas quanto à formação de halo de inibição dos microrganismos através da utilização do paquímetro digital de precisão(0,0001mm) (Mitutoyou Sul Americana Ltda/ Starret Tools®). Este trabalho demonstrou que, in vitro, a adição de diferentes concentrações de digluconato de clorexidina ao sistema adesivo produziu halo de inibição dos microrganismos presentes nas amostras de saliva, independente da concentração utilizada.
|
34 |
[en] FRACTURE RESISTANCE EVALUATION OF ADHESIVE INTERFACES IN DENTAL RESTORATIONS / [pt] AVALIAÇÃO DA RESISTÊNCIA À FRATURA DE INTERFACES ADESIVAS EM RESTAURAÇÕES ODONTOLÓGICASROBERTA AMORIM DE MAGALHAES MONTEIRO GONCALVES 24 June 2014 (has links)
[pt] O sistema adesivo desempenha um papel importante na restauração dental, uma vez que é o responsável por promover a adesão entre o dente e resina. Apesar do avanço deste material, ele ainda pode apresentar problemas quando atua no tratamento restaurador. Sob ação das cargas de mastigação, os possíveis defeitos presentes na interface adesiva podem atuar como concentradores de tensão. Na presença destas descontinuidades, a interface pode comportar-se de maneira frágil, fraturando abruptamente e comprometer a restauração. Quando essa interface não tem muita resistência à fratura, é caracterizada por baixos valores de tenacidade à fratura, KIc. Portanto, o objetivo do presente estudo foi avaliar, por um método alternativo de testes, a tenacidade à fratura da interface dente / restauração utilizando diferentes sistemas adesivos e resinas compostas. Os terceiros molares foram cortados e restaurados com um entalhe pré-existente. De acordo com o material de restauração (adesivos convencional ou autocondicionante; e resinas compostas híbrida ou nanohíbrida), foram divididos em três grupos. A resistência à fratura foi avaliada por meio de testes de KIc, usando corpos de prova nos quais a zona de processo (região da trinca) é similar à interface de restauração. Após o teste, as superfícies de fratura foram analisadas por microscopia óptica (lupa) e microscopia eletrônica de varredura (MEV) para observar os planos de propagação das trincas nesses ensaios de tenacidade. Análise dos testes mostrou que todos os grupos comportaram-se de maneira semelhante (ruptura frágil), o que foi confirmado pelas análises de superfície. A análise estatística dos valores de KIc para cada grupo indicou haver diferença entre os grupos comparados. Juntamente com a análise qualitativa da média e do desvio padrão, é possível concluir que o material utilizado no Grupo 3 teve um desempenho superior aos outros. / [en] The adhesive system plays an important role in dental restoration, since it is responsible for promoting adhesion between the tooth and the composite resin. Despite the advance of this material, it can still present problems when acting in restorative treatment. Under masticatory loads, the possible flaws present in the adhesive interface can act as stress raisers. In the presence of these discontinuities, the interface can behave fragile, fracturing abruptly and compromising the restoration. When this interface has not much resistance to fracture, is characterized by low values of fracture toughness, KIc. Therefore, the aim of the present study was to evaluate, by an alternative method of testing, the fracture toughness of tooth / restoration interface with different adhesive systems and composite resins. Third molars were cut and restored with a pre-existing crack. According to the restorative material (conventional adhesive or self-etching adhesive, and hybrid or nanohybrid composites), they were divided into three groups. The fracture toughness was measured by KIc testing, using specimens in which the process zone (crack region) is similar to restoration‟s interface. After testing, the fracture surfaces were analyzed by optical microscopy (magnifying glass) and scanning electron microscopy (SEM) to observe the propagation of cracks plans. Analysis of the tests showed that all groups behaved similarly (brittle fracture), which was confirmed by surface analyzes. Statistical analysis of the KIc values for each group indicated difference between the compared groups. With the statistical evaluation and a qualitative analysis of the means and standard deviation was possible to conclude the material used in Group 3 had a better performance than the other groups.
|
35 |
Influência das unidades fotoativadoras e do material restaurador indireto sobre a dureza de um cimento resinoso dual auto-adesivo e um cimento resinoso dual convencional por meio de teste de nanoendentação / Influence of curing units and restorative indirect material on hardness of a dual cure self-adhesive resin cement and dual cure conventional resin cement through nanoindentadion testKuguimiya, Rosiane Nogueira 05 December 2013 (has links)
O objetivo deste estudo foi avaliar a dureza de um cimento resinoso dual autoadesivo (RelyX U200) e um cimento resinoso dual convencional (RelyX ARC) fotoativados sob materiais restauradores indiretos, utilizando unidades fotoativadoras com diferentes comprimentos de ondas (LED Elipar Freelight 2, LED Bluephase, Laser AccuCure 3000TM), por meio de teste de nanoendentação. Para a obtenção dos espécimes foram utilizados incisivos bovinos que após profilaxia, foram submetidos a cortes no limite amelo-cementário para a separação da porção coronária. Após inclusão, os espécimes foram submetidos ao desgaste para exposição de dentina e padronização do substrato. Para simular clinicamente restaurações indiretas foram confeccionadas peças em cerâmica IPS e.max® Press (Ivoclar Vivadent) e em resina composta indireta SR Adoro (Ivoclar Vivadent) que foram cimentadas nas superfícies dentinárias. Os espécimes foram seccionados longitudinalmente em baixa velocidade e constante irrigação e polidos em politriz. Foi estabelecido um grupo controle positivo, no qual o cimento foi fotoativado sem a interposição de material restaurador indireto e um grupo controle negativo, no qual, após a cimentação do material restaurador indireto, a fotoativação foi suprimida, ocorrendo apenas a polimerização química do cimento. Todos os espécimes foram armazenados em água destilada a 37°C durante 7 dias e após esse período, foram submetidos ao teste de nanoendentação na linha de cimentação, com o auxílo do ultra-microdurômetro (Shimadzu Dynamic Ultra Micro Hardness Tester). O ciclo aplicado foi de 100mN. Foram realizadas cinco nanoendentações em cada espécime, cujas médias resultaram nos valores de cada superfície. Os resultados obtidos foram submetidos à Análise de Variância e Teste de Tukey (p<0,05). Podese concluir que o cimento RelyX ARC apresentou maiores valores de dureza do que o RelyX U200 e este foi mais dependente da fotoativação para alcançar uma polimerização adequada. A dureza dos cimentos resinosos avaliados foi influenciada negativamente pela interposição do material restaurador indireto e apenas os LEDs foram capazes de manter o mesmo grau de polimerização dos cimentos quando interposto um material restaurador indireto. / This study aimed to evaluate the hardness of a dual cure self-adhesive resin cement (RelyX U200) and a dual cure conventional resin cement (RelyX ARC) light curing units with different wavelengths (Elipar Freelight 2 LED, Bluephase LED, AccuCure 3000TM Laser) through nanoindentadion test. To obtain the specimens bovine incisors were used after prophylaxis. The tooth were sectioned at the limit amelocement for the separation of the coronal portion. After inclusion, the dentin surface of the specimens were exposed to standardize the substrate. To clinically simulate indirect restorations ceramic pieces were made (IPS e.max® Press/Ivoclar Vivadent) and indirect composite resin (SR Adoro/Ivoclar Vivadent) were cemented on dentin surfaces. The specimens were sectioned longitudinally at low speed with constant irrigation and polished. A positive control group was stablished, in which the cement was light cured without the interposition of indirect restorative material, and a negative control group, in which, after cementation of the indirect restorative material, the light curing was removed, occurring only the chemical polymerization of the cement. All specimens were stored in distilled water at 37°C for 7 days. Nanoindentadion hardness of the cement layer was measured under 100mN load (Shimadzu Dynamic Ultra Micro Hardness Tester). Five nanoindentations in each specimen were obtained, which resulted in the average values of each surface. Data were statistically analyzed using ANOVA and Tukey test (p<0,05). RelyX ARC pesented higher values of hardness than RelyX U200 and this was more dependent on the polymerization. The hardness of the evaluated resin cements was negatively influenced by the interposition of an indirect restorative material and only the LEDs were able to maintain the same degree of polymerization of the cement when an indirect restorative material was used.
|
36 |
Estudo do desgaste de ferramentas com e sem revestimentos de filmes finos utilizadas em operações de conformação a frio. / Study on the wear behavior of uncoated and thin film coated tools used in cold forming operations.Mendes, Marco Aurélio Rosso Santana 08 October 2009 (has links)
Este trabalho dedica-se ao estudo dos mecanismos de desgaste de ferramentas utilizadas em processos de conformação a frio, como punções e matrizes. O texto se inicia por uma discussão que há na literatura a respeito do esfolamento (tradução da palavra galling) que é o principal ao mecanismo de desgaste encontrado na conformação a frio. Em seguida apresenta-se uma breve análise do desempenho tribológico de punções usados industrialmente em operações de estampagem. Tornos CNC foram utilizados para a realização de alguns ensaios de desgaste por deslizamento, sem repetição de trilha, com materiais normalmente utilizados em conformação a frio. Ferramentas de aço AISI M2 com e sem revestimentos por filmes finos de TiN e AlTiCrN foram deslizadas contra aços AISI 1045. Resultados de força de atrito e observações das superfícies via microscopia foram obtidos para qualificar as diferentes condições ensaiadas. Ambas as condições de ferramentas revestidas apresentaram desempenho tribológico superior à ferramenta sem revestimento e uma inversão de desempenho foi observada entre as ferramentas revestidas: a ferramenta revestida com o filme de AlTiCrN apresentou um melhor desempenho quando a situação de ensaio foi mais branda. Quando os esforços foram mais severos, o melhor desempenho foi obtido com o revestimento de TiN. A essa inversão de desempenho foi atribuído o acabamento superficial dos filmes finos. / This work is devoted to the study of wear mechanisms in cold forming tools, such as punches and dies. The text begins with a discussion on the galling phenomenon, which is the main wear mechanism that takes place in cold forming operations. A brief analysis of the tribological behavior of punches that have operated in industrial conditions is then presented. Tests of sliding wear without repetition of the wear track were conducted in CNC lathes, considering the contact of materials normally used in cold forming operations. AISI M2 tool steels with and without TiN and AlTiCrN coatings were slided against AISI 1045 steel. Friction force results and microscopic surface observations were analyzed in order to qualify different tests conditions. Both coated tools conditions presented a better tribology performance than the uncoated ones and an inversion in performance was observed between the coated tools: the AlTiCrN coated tool had a better performance in milder conditions, while the TiN coated tool presented a better performance in more severe conditions. This inversion in performance was attributed to the surface finish of the coatings.
|
37 |
Efeito da clorexidina na reidratação da dentina irradiada com laser Er:YAG após envelhecimento / Chlorhexidine effect on rehydration of irradiated dentin with Er:YAG laser after agingGalafassi, Daniel 03 February 2012 (has links)
Esse estudo in vitro avaliou a resistência adesiva da dentina preparada com laser de Er:YAG ou broca, reidratada com clorexidina ou água deionizada, após armazenamento em saliva artificial e termociclagem. Cento e vinte terceiros molares humanos hígidos foram seccionados no terço médio da coroa, expondo a superfície dentinária (n=10). Os espécimes foram divididos aleatóriamente de acordo com o tratamento [laser de Er:YAG + reidratação com água deionizada (LW), laser de Er:YAG + reidratação com clorexidina a 2% (LC), turbina de alta-rotação com broca #245 + reidratação com água deionizada (TW) e turbina de alta-rotação com broca #245 + reidratação com clorexidina a 2% (TC)]. Após o preparo da dentina, os espécimes foram condicionados com ácido fosfórico 35%, lavados e secos com ar. A reidratação da dentina foi realizada através da aplicação de 1.5!L de água deionizada ou clorexidina 2%. Um sistema adesivo etch and rinse foi aplicado seguido da restauração com resina composta. Em cada grupo os espécimes foram sub-divididos de acordo com o envelhecimento [24 horas de armazenamento em saliva artificial / sem termociclagem (NA); 6 meses de armazenamento em saliva artificial / 12.000 ciclos térmicos (6A); 12 meses de armazenamento em saliva artificial / 24.000 ciclos térmicos(12A)]. Após cada período de envelhecimento, os dentes foram seccionados a fim de se obter 4 palitos com area de ±1.0 mm2, que foram submetidos ao teste de microtração usando uma máquina universal de testes com velocidade de 0.5 mm/min. Para a análise da interface adesiva em MEV foram utilizados 36 terceiros molares hígidos (n = 3) que foram restaurados e envelhecidos como descrito no protocolo empregado para o teste adesivo. ANOVA a dois critérios mostrou que não houve diferença significante para a interação entre os fatores e para o fator envelhecimento. O teste de Tukey 5% mostrou que o grupo LC apresentou os menores valores de resistência adesiva. A análise da interface adesiva através da MEV demonstrou que para os grupos irradiados houve formação de camada híbrida irregular com presença de fendas e o envelhecimento não interferiu na morfologia da interface adesiva. A reidratação com clorexidina influenciou negativamente a resistência adesiva do prepare com laser de Er:YAG. O envelhecimento em saliva artificial e termociclagem não interferiram na resistência adesiva da dentina. / This in vitro study evaluated the bond strength of dentin prepared with Er: YAG laser or turbine, rehydrated with chlorhexidine or deionized water after artificial saliva storage and thermocycling. One hundred twenty human third molars were sectioned in order to expose the dentin surface (n=10). The specimens were equally and randomly divided according to treatment [Er:YAG laser + deionized water rehydration (LW), Er:YAG laser + chlorhexidine 2% rehydration (LC), bur on high-speed turbine + deionized water rehydration (BW) and bur on high-speed turbine + chlorhexidine 2% rehydration (BC)]. After dentin preparation, the specimens were etched with 35% phosphoric acid, washed and dried with air. The dentin rehydration method was performed with deionized water or chlorhexidine 2% by applying 1.5!L of each solution. An etch and rinse adhesive system was then applied and the samples were restored with a composite. In each group, the specimens were sub-divided in accordance with the aging method [24 hours artificial saliva storage, no thermocycling (NA); 6 months of artificial saliva storage, 12.000 thermocycling (6A); 12 months of artificial saliva storage, 24.000 thermocycling (12 A)]. After each aging period, each tooth was sectioned in order to obtain 4 sticks with a cross-sectional area of 1.0 mm2, which were submitted to microtensile test using the Universal Test Machine (0.5 mm/min). For the adhesive interface analysis by SEM, 36 healthy third molars (n=3) were restored and aged as the protocol used for the adhesive test. The two-way ANOVA showed no significant differences for the interaction between the factors and for the aging factor. Tukey test 5% showed that the LC group had the lowest bond strength values. The adhesive interface analysis by SEM showed that the irradiated groups presented irregular hybrid layer and cracks and the aging did not affect the adhesive interface morphology. The rehydration with chlorhexidine negatively influenced the bond strength of the preparation with the Er:YAG laser. The artificial saliva aging and thermocycling did not interfere with dentin bond strength.
|
38 |
Efeito do jateamento de óxido de alumínio e uso de selante industrial, na superfície de pilares protéticos Cone Morse, de restaurações implanto suportadas sobre a resistência ao contratorque / Effect of aluminum oxide blasting and use of industrial sealant on the outer abutment surface of the prosthetic morse taper system connection on the untightening torqueTunes, Fábio Sanches Magalhães 18 June 2012 (has links)
Problemas com desenho de conexões protéticas sobre implantes, microfendas, afrouxamento e, consequentemente, perdas das estruturas protéticas reabilitadoras são tópicos frequentes do estudo odontológico. Conexões do tipo Cone Morse, devido às suas características, diminuíram o índice desses problemas, abrindo uma nova perspectiva para o sucesso da prótese sobre implante. Contudo, ainda é frequente encontrar componentes que falham no desempenho, levando à falência da restauração, especialmente quando esses componentes não são bem ajustados, bem fixados ou, ainda, não possuem, na sua geometria, características suficientes para suportar as forças laterais e oclusais de um ciclo mastigatório. O objetivo deste estudo é avaliar a influência do jateamento com óxido de alumínio sobre a superfície externa dos componentes protéticos, separadamente e em conjunto, com um adesivo industrial, em uma tentativa de aumentar os valores de torque de abertura de componentes apertados em seu torque recomendado, pelo fabricante ou menor. Neste ensaio, foram utilizados 36 implantes da marca Straumann®, de 10mm de comprimento com diâmetro de 4,8 mm, os quais foram divididos em 6 grupos: Grupo 1 = controle, torque de 35 N.cm; Grupo 2 = superfície jateada com óxido de alumínio (# 320) e torque de 35 N.cm; Grupo 3 = superfície jateada com óxido de alumínio (# 320) e torque de 25 N.cm; Grupo 4 = superfície jateada com óxido de alumínio (# 100) e torque de 25 N.cm; Grupo 5 = superfície jateada com óxido de alumínio (# 320), aplicação de adesivo e torque de 25 N.cm; Grupo 6 = superfície jateada com óxido de alumínio (# 100), aplicação de adesivo e torque de 25 N.cm, que receberam componentes protéticos sólidos de 5,5 mm de altura, regulares e alterados. As modificações incluídas foram o jateamento com partículas de óxido de alumínio (100 e 320 micra) e o uso de Loctite® 277 como adesivo industrial. Os conjuntos implante-componente foram levados até uma máquina de controle de tração, Instron®, e, após a sua calibração, as amostras dos grupos foram apertadas em 35 e 25 N.cm, com um conjunto catraca-torquímetro, com checagem visual e registro no software acoplado à máquina de ensaio. Após trinta dias, os grupos foram levados à máquina novamente e o conjunto abutment-implante foi desapertado, agora somente com registro no software da máquina de ensaio. Os valores e porcentagens da diferença entre torque de aperto e desaperto foram avaliados estatisticamente, e comparados entre os grupos. Para todas as associações, o valor de p deveria ser menor ou igual 0,05, para relevância. O grupo Jateado 35 N.cm, 320 micra, não apresentou valores mais altos do que o grupo Controle no momento do torque de desaperto, assim como os grupos Jateados 25 N.cm 100 e 320 micra. Os grupos Jateados 25 N.cm, 100 e 320 micra, com adesivo, mostraram uma resistência por volta de uma vez e meia maior, no torque de desaperto do que o grupo Controle 35 N.cm. / Problems with design of prosthetic implant connections, microleakage,! loosening which leads to loss of rehabilitative prosthetic structures are frequent topics of dental study. Morse taper connections, due to its characteristics, decreased the rate of these problems opening a new perspective to the success of the prosthesis supported over implant. However, it is still frequent to find components that fail in performance leading to failure of restoration especially when these components are not well adjusted, tightened or do not have in its geometry enough characteristics to support the occlusal and lateral forces in a masticatory cycle. The aim of this study is to evaluate the influence of blasting with aluminum oxide on the outer surface of the prosthetic components separately and in conjunction with an industrial adhesive in an attempt to increase the opening torque values of components tightened on their recommended torque by the manufacturer or less, therefore allowing the dentist an early intervention in the prosthetic rehabilitation. In this test, 36 Straumann® implants of 10mm high and 4,8mm wide were used. They were divided into six groups: Group 1 Solid abutments control group - 35 N.cm tightened; Group 2 - Solid sandblasted abutments, 35 N.cm aluminum oxide 320 microns size particles; Group 3 - Solid sandblasted abutments, 25 N.cm aluminum oxide 320 microns size particles; Group 4 - Solid sandblasted abutments, 25 N.cm aluminum oxide 100 microns size particles; Group 5 - Solid sandblasted abutments, 25 N.cm aluminum oxide 320 microns size particles with glue application; Group 6 - Solid sandblasted abutments, 25 N.cm aluminum oxide 100 microns size particles with glue application, which received 5,5 mm high regular and modified solid abutments. The included modifications were sandblasting with aluminum oxide particles (100 and 320 microns) and the use of Loctite® 277 as an industrial adhesive. The samples were taken to a traction control test machine, Instron ®, and after calibration the group samples were tightened on 35 and 25 N.cm with a ratchet-wrench set with visual check. The data was recorded in a software coupled to the test machine. After thirty days the groups were brought again to the test machine and the samples were untightened. At this point the resulting data was recorded only in the testing machine software. The values and percentages of the changes between the tightening and loosening torques were recorded and compared among the study groups. For all associations a p-value < 0.05 was considered significant. The group blasted 35 N.cm, 320 microns did not show higher values than the control group at the time of loosening torque as well as groups blasted 25 N.cm 100 and 320 microns. The groups blasted 25 N.cm, 100 and 320 microns with adhesive showed a resistance around one and a half times greater in the loosening torque than the control group 35 N.cm.
|
39 |
Estudo do adesivo poliuretano à base de mamona em madeira laminada colada (MLC) / Study of the polyurethane adhesive based on castor oil in glued laminated timber (GLULAM)Jesus, José Manoel Henriques de 03 May 2000 (has links)
Este trabalho tem por finalidade, o estudo do comportamento do adesivo poliuretano à base de mamona para o emprego em madeira laminada colada (MLC). A eficiência do adesivo foi avaliada por meio da resistência dos seguintes ensaios mecânicos: cisalhamento, tração normal e tração paralela às fibras. Os ensaios seguiram as recomendações da norma brasileira NBR 7190/97 \"Projeto de estruturas de madeiras\" e por meio de seus resultados foram determinados os parâmetros de colagem como: viscosidade (V), tempo de pressão de colagem (Tp), pressão de colagem (P) e tempo de cura (Tc) e avaliadas as influências dessas variáveis e de suas interações sobre as resistências. Duas espécies de madeira foram empregadas: o Pinus caribea hondurensis e o Eucaliptus grandis, geralmente empregadas em reflorestamento nas regiões Sul e Sudeste do Brasil, onde estão localizadas as indústrias de MLC. O adesivo estudado é do tipo bicomponente, o poliol B1640 e o prepolímero A249, oriundo de recurso natural e renovável, de cura a frio, não agressivo ao ser humano e nem ao meio ambiente e é uma tecnologia nacional. Os resultados mostraram que o adesivo à base de mamona é um boa alternativa para a utilização da madeira laminada colada em estruturas com espécies de reflorestamento. / The aim of this work is the study of the polyurethane adhesive based on castor oil in glued laminated timber structures (GLULAM). The efficiency of the adhesive was evaluated using the following mechanical tests: shear, perpendicular and parallel tension to the grain strengths. The Brazilian Code NBR 7190/97 \'\'Design of the timber structures\" was used to the tests and based on these results were determined the gluing parameters as: viscosity (V), gluing pressure (P), time of pressure (Tp) and the curing time (Tc) and evaluated the influence of these variables and interactions on the mechanical strengths. Two wood species Pinus caribea hondurensis and Eucaliptus grandis were chosen because they are used as reforestation in South and Southeast areas in Brazil where are located the glulam industries. The adhesive studied is of the two components, that is, the poliol B1640 and the prepolymer A249 and is made of a natural and renewable resource, cure in the environment conditions, not aggressive to man and the environment, and a national technology. The results showed a good performance of this adhesive, a good technical alternative for the technology utilization of GLULAM in timber structures with reforestation species.
|
40 |
Produção e caracterização de camadas de boretos e carbonetos nos aços AISI 8620, 15B30, 8640 e 52100 / Production and characterization of boride and carbide layers on AISI 8620, 15B30, 8640 and 52100 steelsTriani, Rafael Magalhães 11 July 2018 (has links)
Os aços AISI 8620, 15B30, 8640 e 52100 são amplamente usados como componentes em rolamentos, engrenagens, pistões e discos de arado, estando sujeitos a constante contato relativo e, consequentemente, sobre diferentes formas de desgaste tribológico. O uso de tratamentos que produzam camadas duras e resistente ao desgaste podem aumentar significativamente o tempo em uso e reduzir custos operacionais. Neste trabalho, tais aços, foram submetidos a tratamentos de Boretação e Deposição termorreativa (TRD) e caracterizados por meio de ensaios de dureza, desgaste microadesivo e difração de raios - X. A dureza das camadas foram determinadas, ocorrendo aumento dessa propriedade para valores de 1650 a 1750 HK0.2 e 2000 a 2400 HK0.2 respectivamente para as camadas de boretos e carbonetos, já em relação ao desgaste microadesivo, as camadas de boretos, VC e NbC formadas apresentaram maior resistência ao desgaste quando comparadas aos seus respectivos substratos protegidos. / The AISI 8620, 15B30, 8640 and 52100 steels are widely used as components in bearings, gears, pistons and plow discs, being subject to constant relative contact and, consequently, to different forms of tribological wear. The use of treatments that produce hard layers and wear resistant can significantly increase the time in use and reduce operating costs. In this work, these steels were submitted to Boride and Thermorreative Deposition (TRD) treatments and characterized by tests of hardness, microadhesive wear and X - ray diffraction. The hardness of the layers was determined, increasing this property to values of 1650 to 1750 HK0.2 and 2000 to 2400 HK0.2 respectively for the layers of borides and carbides, already in relation to the microadhesive wear, the boride layers, VC and NbC formed presented higher resistance to wear when compared to their respective protected substrates.
|
Page generated in 0.0536 seconds