• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 191
  • 189
  • 33
  • 13
  • 7
  • 6
  • 5
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 563
  • 170
  • 118
  • 82
  • 77
  • 72
  • 68
  • 48
  • 44
  • 41
  • 39
  • 38
  • 37
  • 36
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Fixação do enxerto ósseo autógeno em bloco com adesivos a base de cianoacrilato ou parafuso de titânio: estudo histológico em coelhos

Rocha, Julierme Ferreira [UNESP] 08 May 2015 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:26:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-05-08. Added 1 bitstream(s) on 2015-09-17T15:45:54Z : No. of bitstreams: 1 000847287.pdf: 1787360 bytes, checksum: ce649e2042005ef102a6638700272935 (MD5) / Os adesivos a base de cianoacrilato são utilizados em cirurgia oral e maxilofacial para fechamento de feridas cirúrgicas, comunicação buco-sinusal, reparo de fissura labial e osteosíntese do esqueleto craniofacial. O objetivo deste trabalho foi comparar três métodos de fixação (etil-cianoacrilato, n-butil-cianoacrilato ou parafuso de titânio) do enxerto ósseo autógeno (EOA) em bloco. Foram realizadas ostectomias bilaterais na região parietal em trinta coelhos com uma trefina de 6mm para obtenção do EOA. Os EOA em bloco obtidos foram fixados com etil-cianoacrilato (Grupo I), n-butil-cianoacrilato (Grupo II) ou parafuso de titânio (Grupo III). Os animais foram sacrificados nos períodos de cinco, quinze, trinta, sessenta e cento e vinte dias, sendo obtidas amostras da região do EOA. As peças foram processadas em laboratório de acordo com o método histotécnico de rotina e coradas com hematoxilina e eosina. Os eventos histológicos avaliados foram: infiltrado inflamatório, reabsorção do adesivo e neoformação e reabsorção óssea. Os resultados dos eventos celulares foram submetidos ao teste de Kruskal-Wallis, seguido pelo teste de Dunn para determinar as diferenças entre os grupos (p < 0.05). A análise qualitativa ordinal mostrou a presença de infiltrado inflamatório e reabsorção óssea mais significativos nos grupos I e II, principalmente nos períodos iniciais. O infiltrado inflamatório observado no grupo controle foi discreto (p<0.05). O processo de reabsorção do adesivo foi semelhante, não havendo diferença estatística (p>0.05). No período de 120 dias, foi possível observar adesivo na interface EOA-leito receptor. A neoformação óssea foi mais intensa no grupo controle e no período de 120 dias, o EOA em bloco... / Cyanoacrylates are used in oral and maxillofacial surgery for closure of surgical wounds, oroantral communication, cleft lip repair, and osteosynthesis of the craniofacial skeleton. The aim of this study was compare three fixation methods (ethyl-cyanoacrylate, n-butyl cyanoacrylate or titanium screw) of autogenous onlay bone graft (AOBG). Bilateral ostectomies were made in the parietal region in thirty rabbits using a 6-mm-diameter trephine. The AOBG was fixed with ethyl-cyanoacrylate (Group I), n-butyl cyanoacrylate (Group II) or titanium screw (Group III - control). The animals were sacrificed at five, fifteen, thirty, sixty, and one hundred and twenty days, and the samples were obtained from AOBG region. The processing was done in accordance with the method histotechnical and stained with hematoxylin and eosin. The evaluated histological events were: inflammatory infiltrate, adhesive resorption and bone formation and bone resorption. The results of cellular events were subjected to the Kruskal-Wallis test followed by Dunn's test to determine differences between groups (p <0.05). The qualitative numerical analysis showed the presence of inflammatory infiltrate and significant bone resorption in groups I and II, especially in the early periods. The inflammatory infiltrate seen in the control group was discrete (p <0.05). The adhesive reabsorption process was similar, with no statistical difference (p> 0.05). After 120 days, we observed residual adhesive between AOBG ...
222

Análise in vitro da resistência adesiva de resinas compostas em cavidades de classe II, através do teste de microtração. Efeito de diferentes técnicas restauradoras

Calixto, Abraham Lincoln [UNESP] 22 July 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-07-22Bitstream added on 2014-06-13T20:01:56Z : No. of bitstreams: 1 calixto_al_dr_arafo.pdf: 933718 bytes, checksum: 50e18e9960ea9272e8e8efc853a8ef95 (MD5) / O objetivo deste trabalho foi analisar in vitro a resistência adesiva, em cavidades de classe II, restauradas com resinas compostas, através do teste de microtração . Foram realizadas cavidades padronizadas, de classe II, tipo slot, nas superfícies mesial e distal de 24 dentes terceiros molares humanos e hígidos. Os dentes foram aleatoriamente divididos em 6 grupos com 16 espécimes cada. O procedimento restaurador foi realizado através de técnica de incrementos múltiplos com as resinas compostas P60 (compactável) e Z250 (multiuso), sob efeito de diferentes técnicas restauradoras, a saber: Grupo PT1- adesivo + P60 ; Grupo PT2- adesivo + P60 + ponta fotocondensadora transparente; Grupo PT3- adesivo + flow + P60; Grupo ZT1- adesivo + Z250; Grupo ZT2- adesivo + Z250 + ponta fotocondensadora transparente; Grupo ZT3- adesivo + flow + Z250. O sistema adesivo utilizado foi o Single Bond (3M ESPE). Após as restaurações, os dentes foram armazenados em água destilada em estufa a 37°C, durante 24 horas. A seguir, os dentes foram termociclados por 500 ciclos (5°-55°) e então, seccionados paralelamente ao longo eixo com disco diamantado, no sentido vestíbulo - lingual e mesio - distal, obtendo-se amostras em forma de palitos, com área de secção transversal de 0,50mmøl0,1mmø . Antes do teste de tração, os palitos tiveram suas áreas de união medidas e anotadas, e então, foram fixados pelas suas extremidades ao dispositivo de microtração com um adesivo instantâneo e a seguir, submetidos ao ensaio de tração em máquina de testes universal (MTS) operada a velocidade de 0,5mm/min. Após a fratura, os valores de resistência adesiva foram calculados e expressos em MPa. O modo da fratura no lado de dentina foi classificada individualmente, com lupa estereoscópica com aumento de 40X. Os dados foram submetidos a análise estatística e demonstrou... / The aim of this work was to analyse in vitro of the tensile bond strength in class II cavities, recuperated with composite resins, throught the microtensile bond test. Standardized cavities were prepared, slot type , in the surfaces mesial and distal of 24 humans molars teeth third and health. The restorations procedures were carried out using the technique of multiple increments with P60 and Z250 resin. The teeth were randoly divided in to 6 groups of 16 specimens each, to know: Group PT1- adhesive+P60; Group PT2- adhesive+P60+ transparent photocondenser point; Group PT3-ahesive+flow+P60; Group ZT1-adhesive+Z250; Group ZT2- adhesive+Z250+ transparent photocondenser point; Group ZT3- adhesive+flow+Z250. The adhesive system were utilized Single Bond (3M/ESPE). After the restorations, the teeth were storage in destilled water for 24h at 37°C. After were thermocycled for 500 cycles at preset temperatures of 5° and 55°C, and the teeth were sectioned with a diamond disc, perpendicularly to the adhesive interface in buccal-lingual an mesio-distal directions, being obtained samples in sticks form with cross-sectional areas of 0,5 mmø. Before testing sticks had their measured and logged union areas. The specimens were then attached to a testing apparatus and tensile load was applied by universal machine at a crosshead speed of 0.5mm/min. After the fracture values of the tensile bond strenght were calculated and expressed in MPa. The dentin surfaces surfaces was examined with aid of glass magnifying stereoscopic with 40X, being verifield the way of failures. The results were submitted statistical analysis showed : 1- the largest values of shear bond strenght went to the group PT2, wich associated the resin P60 with the point photocondenser transparent; 2- the groups that you/they the resin flow didn't present... (Complete abstract, click electronic address below)
223

Citotoxidade direta e transdentinária de sistemas adesivos com diferentes graus de hidrofilia sobre células odontoblastóides

Bianchi, Luciana [UNESP] 19 December 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-12-19Bitstream added on 2014-06-13T19:56:38Z : No. of bitstreams: 1 bianchi_l_me_arafo.pdf: 1440402 bytes, checksum: e46b54f688f969e58ca558c0a1176228 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo geral desse trabalho, dividido em dois experimentos (capítulos 1 e 2), foi avaliar a citotoxicidade de sistemas adesivos experimentais (SAEs), com diferentes graus de hidrofilia, e do etanol como solução de solvatação da dentina, sobre células odontoblastóides. No capítulo 1, discos de papel filtro esterilizados foram impregnados com 10 μL de cada SAE (n=22): R1, R2, R3, R4 e R5 (em ordem crescente de hidrofilia), seguido de fotoativação. Os discos foram individualmente imersos em meio de cultura DMEM para obtenção de extratos (DMEM + componentes liberados dos SAEs), os quais foram posteriormente aplicados sobre células MDPC-­‐23 em cultura. Discos não impregnados (R0) serviram como controle. Foram avaliados o metabolismo celular (teste de MTT), a expressão de proteína total (PT) e a atividade de fosfatase alcalina (FA), além do tipo de morte celular (citometria de fluxo) e grau de conversão monomérica (FTIR) dos SAEs. Os dados de cada variável resposta do estudo foram analisados por testes de Kruskal-­‐Wallis e Mann-­‐Whitney (α=0,05). Considerando R0 como 100%, foi observada redução do metabolismo celular de 36,4%, 3,1%, 0,2%, 21,5% e 65,7%, respectivamente para R1, R2, R3, R4 e R5. Apenas R1 e R5 diferiram estatisticamente do controle. Para PT, R1, R4 e R5 tiveram expressão estatisticamente inferior ao controle, enquanto que a atividade de FA foi significativamente reduzida por R1 e R5. Esses mesmos SAEs juntamente com R4 induziram as maiores porcentagens de morte... / The overall aim of this study, divided into two experiments, was to evaluate the cytotoxicity of experimental adhesive systems (EAS) with different hydrophilicity, and ethanol as a dentin solvation solution, on odontoblast-­‐like cells. In the first experiment, sterilized filter paper discs were impregnated with 10 μL of each EAS: R1, R2, R3, R4 and R5 (in increasing rank of hydrophilicity), followed by light activation. The paper discs were individually immersed in DMEM culture medium for obtaining the extracts (DMEM + released components of EAS), which were applied on MDPC-­‐23 cells in culture. Non-­‐impregnated paper discs (R0) were used as control. Cell metabolism (MTT assay), total protein expression (TP) and alkaline phosphatase activity (ALP) were assessed, in addition to the type of cell death (flow cytometry) and the degree of monomer conversion (FTIR). Data for each response variable were submitted to Kruskal-­‐Wallis and Mann-­‐Whitney tests (α=0.05). Compared to the control (100%), cell metabolism was decreased by 36.4%, 3.1%, 0.2%, 21.5% and 65.7% for R1, R2, R3, R4 and R5, respectively. However, only R1 and R5 differed from the control. R1, R4 and R5 decreased the expression of TP compared to the control, whereas only R1 and R5 significantly reduced the activity of ALP. The later EAS plus R4 caused the highest percentages of cell death by necrosis. A higher percentage of monomer conversion was detected as a function of the hydrophilicity. According to the experimental conditions, it could be... (Complete abstract click electronic access below)
224

Análise da penetração de material resinoso ao esmalte dental em função de agente clareador e tempo

Machado, Jeferson da Silva [UNESP] 02 March 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-03-02Bitstream added on 2014-06-13T19:30:40Z : No. of bitstreams: 1 machado_js_me_arafo.pdf: 2259964 bytes, checksum: 7e24645a8db75d3219fc3b67c94f8d3a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho teve por finalidade analisar a influência do tempo de espera sobre a adaptação e capacidade de penetração de materiais resinosos sobre o esmalte dental submetido ao tratamento clareador através de dois diferentes agentes clareadores, ou sejam: Peróxido de Carbamida 16% (Clarigel Gold - Dentsply) e Peróxido de Hidrogênio 38%(Opalescence X-tra Boost - Ultradent) .Assim, quarenta e oito pré-molares hígidos foram divididos em dois grupos de acordo com o agente clareador a ser utilizado, sendo, cada grupo subdividido em 4 sub-grupos com 6 espécimes de acordo com o tempo de espera para aplicação do material resinoso após o término do tratamento clareador : restauração imediata; 7dias; 14 dias e 30 dias. Após a conclusão do tratamento clareador a análise da adaptação da resina composta foi observada através de microscopia óptica comum sob luz polarizada, em aumento de 200x sendo que, a avaliação da penetração dos prolongamentos resinosos em esmalte dental em aumento de 400x. Os resultados obtidos foram submetidos à análise estatística, sendo que, os dados originais foram transformados em médias proporcionais dos comprimentos dos tags do Grupo Controle e dos Grupos experimentais transformados em arcoseno. Assim, foi realizada Análise de Variância que indicou uma diferença estatisticamente significante para o fator tempo de espera utilizados para execução das restaurações adesivas pós clareamento. O teste de Tukey comprovou que as médias proporcionais dos tempos de aplicação do sistema adesivo pós-clareamento, quando comparados entre si , mostram que os melhores resultados foram obtidos quando o tempo de espera para aplicação do sistema adesivo foi a partir do 7o dia, sendo que o tempo de espera imediato (T1) apresentou as menores médias proporcionais e os tempos T3 e T4 (14 e 30º dias), apresentaram as... . / This work has had the aim to analyse the influence of waiting time on the adaptation and penetration capacity of resinous materials on the dental enamel submithed the bleaching treatment, through the two different bleaching agents, on thus: Carbamide Peroxide 16% (Clarigel Gold - Dentsply) and Hidrogen Peroxide 38% (Opalescense X-tra Boost - Ultradent). So, forty - eight sound bicuspids were divided in two groups according to the bleaching agent to be used, and each subdivided group in 4 (four) with 6 (six) specimens, according to the waiting time to be application of the resinous material, after the end of the bleaching treatment: immediate filling; 7 days; 14 days and 30 days. After the conclusion of the bleaching treatment the analysis of the of the composite resin adaptation was observed through the optical microscopy, under polarized light, in augment of 200x, being that, the penetration assessment of resinous prolongament in the dental enamel in augment of 400x. The results obtained were submitted to the statistical analysis, being that, the original data were transformed in proportional means of lengh of the Control Group tags and the Experimental Groups transformed in archsene. So, the Variance Analyses was made that indicated a statiscally significant difference for the waiting time factor used to perform the adhesive fillings, after bleaching. The Tukey test corroborated that the proportional means of application times of postbleaching adhesive system, when compared among them, show that the best results obtained, when the waiting time to the adhesive system application was since the 7º day, being that the immediate waiting time (T1) presented the minor proportional means and the times T3 e T4 (14 and 30º days), presented the greater proportional means, equalized among them. Besides this results, the optical microscopy... (Complete abstract, click electronic address below).
225

Adesivos estruturais uretânicos aplicados a combinações de compósitos plásticos e metais / Structural urethane adhesives applied in combination of composites, plastics and metals

QUINI, JOSUE G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:33:38Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:04Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
226

Análise da penetração de material resinoso ao esmalte dental em função de agente clareador e tempo /

Machado, Jeferson da Silva. January 2004 (has links)
Orientador: Maria Salete Machado Cândido / Banca: José Roberto Cury Saad / Banca: Dirceu Vieira / Resumo: Este trabalho teve por finalidade analisar a influência do tempo de espera sobre a adaptação e capacidade de penetração de materiais resinosos sobre o esmalte dental submetido ao tratamento clareador através de dois diferentes agentes clareadores, ou sejam: Peróxido de Carbamida 16% (Clarigel Gold - Dentsply) e Peróxido de Hidrogênio 38%(Opalescence X-tra Boost - Ultradent) .Assim, quarenta e oito pré-molares hígidos foram divididos em dois grupos de acordo com o agente clareador a ser utilizado, sendo, cada grupo subdividido em 4 sub-grupos com 6 espécimes de acordo com o tempo de espera para aplicação do material resinoso após o término do tratamento clareador : restauração imediata; 7dias; 14 dias e 30 dias. Após a conclusão do tratamento clareador a análise da adaptação da resina composta foi observada através de microscopia óptica comum sob luz polarizada, em aumento de 200x sendo que, a avaliação da penetração dos prolongamentos resinosos em esmalte dental em aumento de 400x. Os resultados obtidos foram submetidos à análise estatística, sendo que, os dados originais foram transformados em médias proporcionais dos comprimentos dos "tags" do Grupo Controle e dos Grupos experimentais transformados em arcoseno. Assim, foi realizada Análise de Variância que indicou uma diferença estatisticamente significante para o fator tempo de espera utilizados para execução das restaurações adesivas pós clareamento. O teste de Tukey comprovou que as médias proporcionais dos tempos de aplicação do sistema adesivo pós-clareamento, quando comparados entre si , mostram que os melhores resultados foram obtidos quando o tempo de espera para aplicação do sistema adesivo foi a partir do 7o dia, sendo que o tempo de espera imediato (T1) apresentou as menores médias proporcionais e os tempos T3 e T4 (14 e 30º dias), apresentaram as... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: This work has had the aim to analyse the influence of waiting time on the adaptation and penetration capacity of resinous materials on the dental enamel submithed the bleaching treatment, through the two different bleaching agents, on thus: Carbamide Peroxide 16% (Clarigel Gold - Dentsply) and Hidrogen Peroxide 38% (Opalescense X-tra Boost - Ultradent). So, forty - eight sound bicuspids were divided in two groups according to the bleaching agent to be used, and each subdivided group in 4 (four) with 6 (six) specimens, according to the waiting time to be application of the resinous material, after the end of the bleaching treatment: immediate filling; 7 days; 14 days and 30 days. After the conclusion of the bleaching treatment the analysis of the of the composite resin adaptation was observed through the optical microscopy, under polarized light, in augment of 200x, being that, the penetration assessment of resinous prolongament in the dental enamel in augment of 400x. The results obtained were submitted to the statistical analysis, being that, the original data were transformed in proportional means of lengh of the Control Group tags and the Experimental Groups transformed in archsene. So, the Variance Analyses was made that indicated a statiscally significant difference for the waiting time factor used to perform the adhesive fillings, after bleaching. The Tukey test corroborated that the proportional means of application times of postbleaching adhesive system, when compared among them, show that the best results obtained, when the waiting time to the adhesive system application was since the 7º day, being that the immediate waiting time (T1) presented the minor proportional means and the times T3 e T4 (14 and 30º days), presented the greater proportional means, equalized among them. Besides this results, the optical microscopy... (Complete abstract, click electronic address below). / Mestre
227

Desenvolvimento de critérios para seleção de adesivos utilizados na fabricação de pás de turbinas eólicas

Ricci, Ricardo Pedroso [UNESP] 23 June 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-06-23Bitstream added on 2014-06-13T19:00:07Z : No. of bitstreams: 1 ricci_rp_me_bauru.pdf: 3607185 bytes, checksum: d742c0c6ab4783eb07af6258b0f9b7ad (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O processo de fabricação das pás de turbinas eólicas envolve a colagem de estruturas fabricadas em plásticos reforçados com fibra de vidro. Neste trabalho foram analisadas os três principais tipos de adesivos estruturais utilizados pelos fabricante de pás (epóxi, poliuretano e metil-metacrilato), com o objetivo de desenvolver critérios que auxiliem na seleção de adesivos e de tratamentos superficiais aplicados às estrutuaras a serem coladas. A caracterização dos adesivos envolveu dois tipos de ensaios mecânicos: o cisalhamento de juntas de sobreposição simples e a clivagem de juntas adesivas. Dois tipos de tratamento das superfícies dos aderentes foram utilizados: camada de sacrifício removível (peel-ply) e abrasão. Também foi realizada a análise dos modos de falha das juntas ensaiadas como auxílio de compatibilidade entre adesivo e substrato. Os resultados mostram que o tratamento via peel-ply foi o mais eficiente para as juntas coladas com epóxi e testadas em cisalhamento, ao apresentar um aumento de 28% na resistência em relação às superfícies sem tratamento. Imagens de microscopia eletrônica de varredura sugerem que esse tratamento gerou uma área maior de contato em relação à superfície não tratada e que causou menos danos à superfície do aderente do que o método abrasivo. Os grupos colados com adesivo metil metacrilato, independentemente do tipo de tratamento, obtiveram os maiores valores nos ensaios de clivagem, cerca de 170% superiores aos demais grupos. Para estruturas de pás corretamente projetadas para evitar cargas de peeling em suas juntas adesivas, este trabalho mostra que a melhor opção são aderentes tratados com peel-ply e colados com epóxi. Contudo, um plano de testes deve ser elaborado sempre que houver a necessidade do emprego de um novo adesivo ou método de preparação superficial / The manufacturing process of wind turbine blades involves the bonding of structures made of glass reinforced plastic. This work analyzes the theree main types of structural adhesives used by blades manufactures (epoxy, polyurethane and methyl methacrylate), with the goal of developing criteria to assist in the selection of adhesives and surface treatments applied to the structures to be bonded. The characterization of the adhesives involved two types of mechanical tests: single lap shear joints and cleavage of adhesive joints. Two types of surface treatment of the adherents were used: removable sacrifical layer (peel-ply) and abrasion. The joint failure mode analysis was also carried out as an aid to the study of compatibility between adhesive and substrate. The results show that treatment via peel-ply was the most efficient for epoxy bonded substrates tested in shear, by presenting a 28% increase in strengh compared to untreated surfaces. Images of scanning electron microscopy suggest that this treatment led to a larger area of contact relative to untreated surfaces and caused less damage to the substrate's surface than the abrasive method. The groups bonded with methyl methacrylate regardless the type of treatment, had the highest values in the cleavage test, approximately 170% higher than other groups. For propertly designed blades, that avoid peeling loads in their adhesive joints, this work shows that the best option are substrate treated with peel-ply and bonded with epoxy. However, a test plan should be prepared whenever there is the necessity of using a new adhesive or method of surface preparation
228

Painéis de madeira aglomerada produzidos com resíduos de serragem e poliestireno expandido para aplicações na construção civil / Particleboards produced with residues of sawdust from sawmill and expanded polystyrene to the application in construction

Jane Eliza de Almeida Lacombe 03 December 2015 (has links)
As placas de madeira aglomerada, amplamente empregadas para fabricação de móveis, estão consolidadas no mercado, mas merecem especial atenção devido ao seu alto custo quanto aos adesivos empregados e principalmente à vulnerabilidade à umidade se caso entre em contato com a mesma. Diante os fatos, este trabalho apresenta uma nova alternativa de adesivo, empregado por meio de aparas de isopor (EPS), largamente encontrados como resíduos, e o mesmo, ao envolver as partículas de madeira, material também empregado para a fabricação dos painéis, o torna apto para emprego em ambientes ligados diretamente à umidade, sejam eles internos ou externos à edificação. Com isso, o presente trabalho apresenta a elaboração e a proposta de utilização de um novo produto em forma de painel de madeira, produzido com serragem residual de serrarias, como partículas, e EPS (isopor) dissolvido, como adesivo, que possam ser empregados também na construção civil. Assim, foram produzidos painéis com quatro espécies de resíduos de madeira: pinus, eucalipto, teca e peroba. De cada uma das amostras, foram confeccionados dez painéis para a avaliação das características física, mecânica e outros ensaios. Dos resultados de caracterização física, pode-se concluir que os painéis estão conforme padrões exigidos pela norma brasileira NBR 14.810-2 - \"Chapas de madeira aglomerada\" da ABNT (2006b), e, devido aos baixos valores de inchamento, são adequados à utilização em ambientes úmidos e/ou externos. Dos resultados de caracterização mecânica, os painéis apresentaram bons resultados quanto à ligação interna e compressão, indicando ser promissor o uso de isopor como adesivo bem como sua utilização atrelada a painéis de fechamento. Entretanto, como os resultados de flexão estática não foram satisfatórios, prova-se que tais painéis não podem ser solicitados estruturalmente. Quanto aos outros ensaios realizados, todos os resultados foram favoráveis e, se utilizados conforme especificações técnicas, tornam-se coerentes para empregos em edificação. Como resultado, observou-se que os painéis podem ser produzidos e utilizados no mercado da construção civil, certificando que o produto pode ser empregado de forma segura, desde que sejam conhecidas suas funções, tempo de uso e manutenções necessárias. Desta forma, pretende-se contribuir para a produção e a análise de novos materiais que possam colaborar com a melhoria ambiental. / The particleboards, which are widely employed to manufacturing furniture, are established in the market, but they deserve a special attention due to their high cost considering the adhesives used on them and, paramountly, due to their vulnerability to humidity if on contact with their own parts. Facing the facts, this work presents a new alternative adhesive, applied with Styrofoam trims (EPS), usually found as residues, it may be used for involving the particles of wood, which are also used for manufacturing of the panels, and it makes it suitable for the use in environments directly related to humidity, whether it is internal or external to the building. Therewith, this work introduce the explanation and the proposition of the use of a new product in the shape of wood panel, produced with residual sawdust from sawmills, as particles and the EPS (Styrofoam) dissolved as an adhesive, which might also be used in construction. So, panels have been produced with four kinds of residual wood: pine, eucalyptus, teak and peroba. From each one of the samples, it has been manufactured ten boards for the evaluation of the physical and mechanical characteristics and other tests. From the results of physical description, it may be concluded the panels are in conformity with the requirements of the Brazilian standard NBR 14810-2 - \"Particleboards\" from ABNT (2006b), and due to low swelling values are appropriate to use it in humid and or outdoor environments. The results of mechanical description, the panels have shown satisfying results as for the internal connection and compression, indicating it is promising the use of Styrofoam as an adhesive and also its use in cable management panels. However, since the results of the static bending were not sufficient, it is proved such panels cannot be ordered, structurally. As for the other tests, all the results were positive and if they were used according to the technical specifications, they would become consistent for the application in construction. As a result, it was observed the panels might be produced and used in the market of construction, confirming the product may be applied safely as long as their functions are recognized, useful life, and required maintenance. In this way, it is intended to contribute to the production and analysis of new materials which may collaborate to improvement of the environment.
229

Efeito da clorexidina na resistência de união entre adesivo autocondicionante e dentina / Effect of chlorhexidine on bond strength between self-etching adhesive and dentin

Pomacóndor Hernández, César Alberto, 1982- 18 August 2018 (has links)
Orientador: Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T00:53:20Z (GMT). No. of bitstreams: 1 PomacondorHernandez_CesarAlberto_M.pdf: 1946502 bytes, checksum: 842f8e2e23f8ff6c74e3ea3a3c2f7637 (MD5) Previous issue date: 2011 / Resumo: Na tentativa de prolongar a durabilidade da união resina-dentina, a clorexidina aparece como uma alternativa para preservar a integridade do componente colágeno não envolvido pela camada híbrida. O presente estudo teve como objetivo avaliar o efeito da clorexidina na interação entre o adesivo autocondicionante de dois frascos Adper SE Plus (3M ESPE) e a dentina nas variáveis: a) resistência de união (RU) após 1 dia, 3 meses e 6 meses de armazenamento em água, e b) padrão de fratura. Foram obtidos oito terceiros molares humanos recém extraídos e livres de cárie. O esmalte oclusal e a raiz foram removidos para obter um bloco de dentina de 4mm de espessura com uma superfície plana em dentina média. Cada bloco foi cortado longitudinalmente em duas metades resultando em oito hemiblocos para cada um dos Grupos Controle (C) e Experimental (CHX). Para o Grupo Controle, o Adper SE Plus foi aplicado seguindo as instruções do fabricante: 1 - aplicação do Líquido A, 2 - aplicação ativa do Líquido B por 20s, 3 - leve jato de ar comprimido durante 10s, 4 - aplicação de uma segunda camada de Líquido B, 5 - leve jato de ar comprimido. O adesivo foi fotoativado durante 10s usando a unidade de luz visível Elipar Freelight 2 (3M ESPE) com intensidade de 900 mW/cm2. Para o Grupo Experimental, foi realizado o mesmo procedimento substituindo o Líquido A por uma solução aquosa de digluconato de clorexidina a 2% em peso. Foram construídos blocos de resina composta Filtek Z250 (3M ESPE) sobre a dentina em seis incrementos de 1mm sendo fotoativados durante 20s cada. Depois de 24 horas de armazenamento em água destilada a 37°C, os hemiblocos restaurados foram seccionados perpendiculares à região adesiva nos sentidos mesiodistal e bucolingual e obtidos de 8 a 10 palitos de 0,9mm2 (±0,2mm2), os quais foram divididos aleatoriamente em três grupos de 2 a 4 palitos cada e avaliados após 1 dia, 3 meses e 6 meses de armazenamento em água destilada a 37°C. Para o teste de microtração cada palito foi submetido à tração sob velocidade de 0,5mm/min em uma máquina de ensaios universais. Os valores de RU foram submetidos à Análise de Variância de dois fatores para medidas repetidas (?=0,05), e os padrões de fratura classificados em Microscópio Eletrônico de Varredura. O Grupo Controle apresentou valores de RU estatisticamente não diferentes entre si após 1 dia, 3 meses e 6 meses de armazenamento (46,43±11,46 MPa; 50,02±13,84 MPa; 45,18±17,92 MPa, respectivamente). Os valores de RU do Grupo Experimental também resultaram estatisticamente não diferentes entre si nos mesmos tempos de armazenamento (37,22±10,45 MPa; 47,29±12,67 MPa; 40,22±10,01 MPa, respectivamente). Não houve diferença estatística nos valores de RU entre os Grupos Controle e Experimental. Houve predominância de padrões de fraturas coesiva no adesivo, e mista coesiva no adesivo e na resina composta em ambos os grupos e em todos os tempos de armazenamento. Dentro das condições deste estudo, conclui-se que a RU à dentina do Adper SE Plus não diminuiu com o tempo, e não foi negativamente afetada pela clorexidina a 2% / Abstract: In the search for durability of resin-dentin bond, chlorhexidine appears as an alternative to preserve integrity of collagen component not involved by the hybrid layer. This study aimed to evaluate the effect of chlorhexidine in the interaction between two-bottle self-etching adhesive Adper SE Plus (3M ESPE) and dentin, in terms of bond strength (BS) after 1 day, 3 months and 6 months of water storage, and fracture mode analysis. Eight fresh caries-free human third molars were obtained. The occlusal enamel and roots were removed to obtain a 4mm-thick dentin block with a flat surface in middle dentin. Each dentin block was cut longitudinally into halves resulting in eight hemi-blocks for each of the Control (C) and Experimental (CHX) Groups. For the Control Group, Adper SE Plus was applied following the manufacturer's instructions: 1 - application of Liquid A, 2 - active application of Liquid B for 20s, 3 - gentle compressed air stream for 10s, 4 - application of a second layer of Liquid B, 5 - gentle compressed air stream. The adhesive was light cured for 10s using light unit Elipar Freelight 2 (3M ESPE) with a minimum intensity of 900 mW/cm2. For the Experimental Group, it was performed the same procedure replacing the Liquid A with a solution of 2 wt% chlorhexidine digluconate. Resin composite build-ups were constructed with Filtek Z250 resin composite (3M ESPE) in six increments of 1mm and were light cured for 20s each. After 24 hours storage in distilled water at 37°C, restored hemi-blocks were sectioned perpendicular to the adhesive region in mesiodistal and buccolingual directions and were obtained 8 to 10 beams of 0.9mm2 (±0.2mm2), which were randomly divided into three groups of 2 to 4 beams and evaluated after 1 day, 3 months and 6 months of storage in distilled water at 37°C. For the microtensile test, each beam was tested on tensile until failure at a crosshead speed of 0.5mm/min in a universal testing machine. The BS values were subjected to two-way repeated measures ANOVA (?=0.05), and fracture mode classified in Scanning Electron Microscope. The Control Group had BS values not statistically different from each other after 1 day, 3 months and 6 months of storage (46,43±11,46 MPa; 50,02±13,84 MPa; 45,18±17,92 MPa, respectively). The BS in the Experimental Group also resulted not statistically different from each other at the same times of storage (37,22±10,45 MPa; 47,29±12,67 MPa; 40,22±10,01 MPa, respectively). There was no statistical difference in BS values between Control and Experimental Groups. There was a predominance of cohesive failure within adhesive resin, and mixed cohesive failure within adhesive resin and resin composite in both groups at all storage times. Under the conditions of this study, it can be concluded that BS of Adper SE Plus to dentin did not diminish with time, and was not adversely affected by 2% chlorhexidine / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
230

Efeito da remoção do colageno na infiltração marginal em restaurações de resina composta utilizando dois sistemas adesivos de frasco unico

Saboia, Vicente de Paulo Aragão 16 February 2001 (has links)
Orientador: Luiz Andre Freire Pimenta / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T00:22:23Z (GMT). No. of bitstreams: 1 Saboia_VicentedePauloAragao_D.pdf: 2377804 bytes, checksum: b83955fe9c76b5de6e7f36a75db01b3f (MD5) Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar o efeito da remoção do colágeno na infiltração marginal de corante na interface adesiva de restaurações de resina composta utilizando dois sistemas adesivos de frasco único, envelhecidas através de ciclagem térmica e estocagem em água durante 1 ano. Foram usadas 40 raízes de terceiros molares humanos recém-extraídos e armazenados em formol a 10%. A câmara pulpar e o ápice radicular foram vedados com resina composta. Cada raiz recebeu dois preparos cavitários cilíndricos com dimensões de 2 mm de diâmetro por 2 mm de profundidade. Após sorteio, foram criados dois conjuntos de 20 raízes cujas cavidades foram restauradas utilizando-se os adesivos Prime & Bond 2.1 (PB-Dentsply) ou Single Bond (SB-3M). Cada porção radicular recebeu uma restauração pela técnica da hibridização (controle) e outra após o tratamento da dentina com NaOCI (hipoclorito de sódio) a 10% por 60 s para remoção de colágeno (teste). Ficaram estabelecidos 4 grupos de 20 cavidades assim distribuídas: G1(PBSH)-PB sem NaOCI; G2(PBCH)-PB com NaOCI; G3(SBSH)- SB sem NaOCI e G4(SBCH)-SB com NaOCI. Todas as cavidades foram restauradas com resina composta Z 100 (3M) de acordo com as instruções do fabricante. Os espécimes foram submetidos a 5000 ciclos térmicos (5-55 °C) e armazenados em água à 37°C. Após 1 ano, os remanescentes radiculares foram vedados e imersos em solução de azul de metileno a 2% por 4 horas. As restaurações, foram seccionadas no sentido longitudinal da raiz e observadas em lupa estereoscópica com 45 vezes de aumento. De acordo com a penetração do corante nas margens da restauração foram atribuídos escores de 0 a 4, os quais foram tabulados e submetidos ao teste Exato de Fisher. A remoção do colágeno reduziu significativamente os índices de microinfiltração para o adesivo à base de acetona (Prime & Bond 2.1) enquanto que para o adesivo à base de água (Single Bond) este tratamento não influenciou os índices de microinfiltração / Abstract: The aim of this study was to evaluate the effect of collagen removaI on the microleakage of two single-bottle adhesive systems. Forty human third molars were selected and each of them received two preparations on its roots. The roots were randomly assigned to be restored using Prime & Bond 2.1(PB-Dentsply) or Single Bond (SB-3M). One of the cavities in each root was treated with 'H IND. 3¿¿PO IND. 4¿ and the other received an additional treatment with 10% sodium hypochlorite (NaOCI) for 60 s before adhesive application for removaI of collagen layer. Four groups were created: G1(PBSH)-PB without NaOCI; G2(PBCH)-PB with NaOCI; G3(SBSH)-SB without NaOCI and G4(SBCH)-SB with NaOCI. All the cavities were restored with Z 100 restorative resin (3M). The specimens were submitted to 5,000 thermal cycles (5-55 °C) and stored in 37°C water for 1 year. After this time the specimens were coated with a varnish except for 1 mm of tooth structure surrounding the restoration and immersed in 2% blue methylene for 4 hours. After rinsing, the restorations were sectioned and two independent observers, using a light microscopy at x45 magnification, scored (0 - 4) the microleakage at the interface between restorative material and tooth. The scores were submitted to Fisher's Exact Test and the results showed that collagen removal reduced significantly the microleakage for Prime & Bond 2.1 and had not effect on microleakage for Single Bond / Doutorado / Dentística / Doutor em Clínica Odontológica

Page generated in 0.0464 seconds