• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 181
  • 125
  • 74
  • 36
  • 5
  • 5
  • 5
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 717
  • 717
  • 280
  • 273
  • 159
  • 141
  • 104
  • 102
  • 75
  • 70
  • 67
  • 63
  • 58
  • 57
  • 54
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
391

Simulation of a building heating, ventilating and air-conditioning system

Botha, C P 03 July 2006 (has links)
Simulation is one of the oldest and also among the most important tools available to engineers. In the building Heating, Ventilating and Air-Conditioning (HVAC) community the availability and/or functionality of simulation tools is limited and it is difficult to determine whether the simulation models accurately represent reality. The purpose of this study was to accurately verify one such a simulation model and then to extend the study to two unique applications. Comprehensive structural, comfort and energy audits were performed to construct a suitable simulation model with the aid of the control simulation package: QUICK Control. The model was then verified against measured building data to ensure an accurate representation of the actual dynamic building response. For the first application various control retrofits were evaluated and the highest potential for energy saving was found. Thereafter the model was implemented to investigate the change in indoor air conditions due to failure of HVAC equipment. Heating, ventilating and air-conditioning in buildings consume a significant portion of the available electrical energy in South Africa. Of this energy up to 30% can be saved by improving the HVAC systems currently installed in the buildings. This could result in savings of up to R400 million. For the building used in this study it was found that up to 66% of the HVAC system’s electrical energy consumption could be saved with a payback period of only 9 months. These savings could be achieved by implementing a setback control strategy with an improved time management procedure. Predicting the impact of failing equipment is a difficult task because of the integrated dynamic effect every HVAC component has on the next. With the aid of a comprehensive integrated simulation model the implications of failing can be determined and necessary assessments and precautions can be taken. The results of this study showed that the air-conditioning system under investigation was approximately 100% over designed. Failure of up to 50% was allowable in the cooling equipment before any noticeable impact could be observed in the indoor climate. With further failure the required comfort conditions could not be sustained. <p The substantial savings calculation and possibility of predicting climate deterioration would not have been possible without the aid of a comprehensive simulation package and model. This study clearly highlights the worth of integrated simulation. / Dissertation (MSc (Mechanical Engineering))--University of Pretoria, 2006. / Mechanical and Aeronautical Engineering / unrestricted
392

Výpočet tepelné zátěže vlakové klimatizační jednotky / Calculation of the heat load of the train air conditioning unit

Kasal, Milan January 2018 (has links)
The subject of this diploma thesis is to apply the knowledge of thermodynamics when designing parameters of the train air conditioning unit. In the first part, the issue of air conditioning technology, basic types of cooling circuits and description of individual components are outlined. Furthermore, there is an overview of groups of refrigerants and their labelling. In the second part, a calculation of the heat load of the train unit for the limit design conditions of summer and winter operation, including the application of humid air theory are to be found. There is a basic procedure for designing the main components of compressor cooling, which is almost exclusively used in train applications, outlined. The last part contains the procedure for calculating the gains/losses in the distribution channels of the real air conditioning unit M7 and the evaluation of the results. In the appendix, there is an SW in MS Excel program, which can be indicatively used to calculate the total gains/losses of the distribution channels on any air-conditioning unit before the air enters into the train unit.
393

Klimatizace učeben a kanceláří / Air-conditioning of lecture rooms and offices

Bečvář, Jaroslav January 2008 (has links)
The diploma thesis is consisting of two parts. Forepart is a theoretic survey. It construes basic office of the air conditioning and deal with used air conditioner arrangements. More deeply it deals with air conditioner systems with refrigerant and the air conditioning for electronic equipments. Project of split system for air conditioning lecture rooms and schoolrooms, and units for air conditioning rooms with cluster and server is processed in the second part. Project is derives from calculation thermal stress of air conditioned space. There is calculated price of air conditioner system and made comparison offers of several accessible suppliers. Elaboration drawing documentation of project is part of the diploma thesis.
394

Modeling and analysis of an air handling unit to improve energy efficiency

Li, Jing 08 1900 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / The Air Handling Unit (AHU), which serves the entire basement of Engineering and Technology (ET) building on IUPUI campus, had constant set points of discharge air temperature and supply air static pressure. Two reset schedules were investigated to determine which was the best control strategy to minimize energy consumption of the AHU. In this research, a gray box model was established to create the baseline of energy consumption with constant set points and predict the energy savings using two di↵erent reset schedules. The mathematical model was developed in Engineering Equation Solver (EES). It was validated using two sets of sub hourly real time data. The model performance was evaluated employing Mean Absolute Percentage Error (MAPE) and Root Mean Square Deviation (RMSD). Additionally, uncertainty propagation identified outside air temperature, supply airflow rate and return air temperature were the key parameters that had an impact in overall energy consumption. Discharge air temperature was reset based on return air temperature (RA-T) with a linear reset schedule from March 4 to March 7. Static pressure was reset based on the widest open Variable Air Volume (VAV) box damper from March 20 to March 23. Results indicated that 17% energy savings was achieved using discharge air temperature reset while the energy consumption reduced by 7% using static pressure reset.
395

Návrh vzduchotechniky ve sportovní hale / Design of ventilation in sports hall

Kučera, Martin Unknown Date (has links)
The work deals with the ventilation system for the gym. Air conditioning ensures forced ventilation and air supply adjustment to ensure the required temperature and humidity of the indoor climate. The theoretical part is focused on air distribution in ventilation systém.
396

Annual energy consumption of reciprocating refrigeration systems for humidity control

Meitl, Thomas J. January 1985 (has links)
Call number: LD2668 .T4 1985 M44 / Master of Science
397

Heat recovery units in ventilation : Investigation of the heat recovery system for LB20 and LB21 in Building 99, University of Gävle

Duarte, Marta January 2016 (has links)
Heating, ventilation and air-conditioning (HVAC) systems are widely distributed over the world due to their capacity to adjust some local climate parameters, like temperature, relative humidity, cleanliness and distribution of the air until the desired levels verified in a hypothetical ideal climate. A review of buildings’ energy usage in developed countries shows that in the present this energy service is responsible for a portion of about 20% of the final energy usage on them, increasing up to 50% in hot-humid countries. In order to decrease this value, more and more different heat recovery systems have been developed and implemented over the last decades. Nowadays it is mandatory to install one of these units when the design conditions are above the limit values to avoid such components, what is possible to verify mostly in non-residential buildings. Each one of those units has its own performance and working characteristics that turns it more indicated to make part of a certain ventilation system in particular. Air-to-air energy recovery ventilation is based on the heat recovery transfer (latent and/or sensible) from the flow at high temperature to the flow at lower temperature, pre-warming the outdoor supply air (in the case of the winter). Therefore, it is important to understand in which concept those units have to be used and more important than that, how they work, helping to visualize their final effect on the HVAC system. The major aims of this study were to investigate the actual performance of the heat recovery units for LB20 and LB21 in building 99 at the University of Gävle and make some suggestions that could enhance their actual efficiency. Furthermore, the energy transfer rates associated to the heat recovery units were calculated in order to understand the impact of such components in the overall HVAC system as also the possible financial opportunity by making small improvements in the same units. To assess the system, values of temperature and flow (among others) were collected in the air stream and in the ethylene-glycol solution that works as heat transfer medium between air streams and is  enclosed in pipes that make part of the actual run-around heat recovery units. After some calculations, it was obtained that for the coldest day of measurements, the sensible effectiveness was 42% in LB20 and 47% in LB21, changing to 44% and 43% in the warmer day, respectively. The actual heat transfer representing the savings in the supply air stream is higher on the coldest day, with values of 46 kW in LB20 and 84 kW in LB21, justifying the existence of the heat recovery units even if those ones imply the use of hydraulic pumps to ensure the loop. The low values of efficiency have shown that both heat recovery units are working below the desired performance similarly to the pumps that make part of the same units.  This fact, together with the degradation of the units that is possible to observe in the local, indicates that a complete cleaning (followed by a change of the heat transfer medium) of the heat recovery units and a new adjustment of pumps and valves for the further changes, are necessary. By doing this, it is expected to see the year average sensible effectiveness increase to close to 45% in both units which will lead to a potential economic saving of around 41 000 SEK per year.
398

Heat Exchanger Design in Mobile Machines

Magdanz, Alex, Schiefer, Michael 28 April 2016 (has links) (PDF)
This paper examines the model-based design of thermal systems in mobile machines with a focus on heat exchanger design. An industry project is described in which the vapor compression cycle for the air-conditioning system was modeled using the software SimulationX. By modeling heat exchanger sections separately, multiple flow arrangements could be tested without the need for physical prototypes. The paper presents this work in the context of the full model-based design process including extensions for hardware in the loop (HiL) testing of control units and operator training using virtual machines.
399

The effectiveness of axial flow fans in a-frame plenums

Venter, Sarel Jacobus, Kroger, D. G. 03 1900 (has links)
Thesis (PhD (Mechanical and Mechatronic Engineering)--University of Stellenbosch, 1990. / 260 leaves printed single pages, preliminary pages i-xxi and numbered pages Chapter 1/1.1-1.3, Chapter 2/2.1-2.17, Chapter 3/3.1.1-3.10, Chapter 4/4.1-4.18, Chapter 5/5.1-5.3, References pages R.1-R.7, Appendix A pages A.1-A.34, Appendix B pages B.1-B.34, Appendix C pages C.1-C.26, Appendix D pages D.1-D.16, Appendix E pages E.1-E.30, Appendix F pages F.1-F.39. Includes bibliography, list of tables, figures and symbols. / Digitized at 600 dpi grayscale to pdf format (OCR), using a Bizhub 250 Konica Minolta Scanner. / ENGLISH ABSTRACT: The ultimate goal of this project is to ensure a better understanding of the governing mechanisms present when flow distorting components are installed in close proximity of an axial flow fan. The effect of different parameters on the operation of axial flow fans is investigated. These parameters are divided into flow enhancing and flow reduction effects. The performance of an axial flow fan can be enhanced by changing the tip clearance, by adding a solid disc to the hub of the fan or by varying the number of fan blades. Flow reductions are caused by components such as inlet grids, walkways and their supporting structures, heat exchangers and windwalls. The effects of flow enhancing components are measured and compared to the results of other authors. The sensitivity of these effects to parameters such as the type of fan rotor and the specific system in which the rotor is installed is highlighted. The system effect (the interaction between the fan rotor and flow resistances in close proximity of each other) of individual components, as well as the combination of different components, is predicted both theoretically and experimentally. These predictions are compared to measured data relevant to the components in an installation where the system effects are present. The results are correlated to the kinetic energy flux coefficient of the flow at different locations within the installation. Experimental data obtained from a full scale unit (inlet shroud diameter of 9,216 m) are used to compare to scaled data from the model (inlet shroud diameter of 1,542 m). The hub to tip ratio of the axial flow fans investigated is 0,15. The most important conclusions are that the performance of the type of axial flow fan under investigation can be improved by reducing its tip clearance and by installing a solid disc to the downstream side of the rotor. An increase in the number of blades of the fan leads to only marginal improvements in the fan performance. The overall performance of the system can also be improved by removing some of the flow resisting components, or by changing their relative positions. All these conclusions are based on the assumption that the power input to the fan rotor remains constant. / AFRIKAANSE OPSOMMING: Die uiteindelike doel van hierdie projek is om te verseker dat die beherende meganismes wat teenwoordig is wanneer vloeiversteurende komponente in die nabyheid van 'n aksiaalwaaier geinstalleer word, beter verstaan word. Die effek van verskillende parameters op die werkverrigting van aksiaalwaaiers word ondersoek. Hierdie parameters word verdeel in vloeiverbeterings- en vloeiverminderingseffekte. Die werkverrigting van 'n aksiaalwaaier kan verbeter word deur die lempuntspeling te verstel, deur 'n soliede skyf aan die naaf van die waaierrotor te installeer, of deur die aantal lemme te verander. Die vloeiverminderings word veroorsaak deur inlaatsiwwe, loopvlakke en hul ondersteuningsstrukture, warmteruilers en windwande. Die effekte van vloeiverbeteringskomponente word gemeet en vergelyk met die resultate van ander outeurs. Die sensitiwiteit van hierdie effekte op parameters soos die tipe rotor en die spesifieke stelsel waarin die rotor geinstalleer is, word uitgelig. Die stelseleffek (die interaksie tussen die rotor van die waaier en vloei weerstande wat naby mekaar geinstalleer is) van individuele, sowel as 'n kombinasie van verskillende komponente, word teoreties en eksperimenteel voorspel. Hierdie voorspellings word dan vergelyk met eksperimentele data wat van toepassing is op die komponente in 'n installasie waar stelseleffekte voorkom. Die resultate word gekoppel aan die kinetiese energievloedkoeffisient van die vloei by verskillende posisies binne die installasie. Eksperimentele data, verkry vanaf 'n volskaaleenheid (inlaatmondstukdiameter van 9,216 m), word met die geskaleerde data van die model (inlaatmondstukdiameter van 1,542 m) vcrgelyk. Die naaf- tot hulsverhouding van die aksiaalwaaiers wat ondersoek word is 0,15. Die belangrikste gevolgtrekkings is dat die werkverrigting van die tipe aksiaalwaaier wat ondersoek word verbeter kan word deur die lempuntspeling te verminder en deur 'n soliede skyf te installeer by die stroomaf kant van die rotor. 'n Toename in die aantal lemme van die waaier lei slegs tot marginale verbeterings in die werkverrigting van die waaier. Die totale werkverrigting van die stesel kan ook verbeter word deur sommige vloeiweerstandskomponente te verwyder, of deur hulle relatiewe posisies te verander. Al hierdie gevolgtrekkings is gebasseer op die aanname dat die drywingsinset na die waaierrotor konstant bly.
400

Computer modelling and simulation of geothermal heat pump and ground-coupled liquid desiccant air conditioning systems in sub-tropicalregions

Lee, Chun-kwong., 李振光. January 2008 (has links)
published_or_final_version / Mechanical Engineering / Doctoral / Doctor of Philosophy

Page generated in 0.1091 seconds