• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 49
  • 1
  • 1
  • Tagged with
  • 51
  • 35
  • 14
  • 13
  • 13
  • 13
  • 12
  • 12
  • 12
  • 12
  • 12
  • 11
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Desenvolvimento de sensores eletroquímicos associados a batch injection analysis (bia) para aplicações analíticas / Development of electrochemical sensors associated with batch injection analysis (BIA) for analytical applications

Maria do Socorro Maia Quintino 11 December 2003 (has links)
Sensores eletroquímicos, constituídos de substratos metálicos modificados por metaloporfirinas e de superfícies livres de agentes modificadores, foram desenvolvidos com vistas a aplicações analíticas. Eletrodos de cobre apresentaram ação eletrocatalítica para a oxidação de ácido acetilsalícílico, com possível participação de Cu(III) como mediador na reação de transferência de elétrons. A oxidação de salbutamol sobre eletrodos de carbono vítreo foi conduzida em solução fortemente alcalina, condição na qual a determinação do analito foi viabilizada devido à eliminação de problemas associados à presença de interferentes e ao envenenamento do eletrodo. Superfícies de carbono vítreo, modificadas por adsorção e por eletropolimerização de porfirinas tetrarrutenadas de cobalto (CoTRP) e de níquel (NiTRP), respectivamente, demonstraram a versatilidade que tais compostos oferecem quanto ao modo de recobrimento do sensor, levando à obtenção de efeitos atrativos, tais como eletrocatálise e prevenção de envenenamento. Filmes de CoTRP, cujos sítios ativos são atribuídos ao par redox Ru(III)/Ru(II), mostraram-se úteis na determinação de acetaminofen, facilitando a reação de transferência de elétrons e protegendo o eletrodo contra o envenenamento. A atividade eletrocatalítica de eletrodos modificados por NiTRP, baseados em filmes com centros redox Ni(III)/Ni(II), foi evidente para a oxidação de glicose e de outros compostos orgânicos em meio alcalino. Os sensores desenvolvidos foram adaptados ao sistema BIA (batch injection analysis) para a determinação amperométrica dos analitos em amostras de produtos farmacêuticos. O método BIA mostrou-se adequado para as análises, sendo possível obter sinais transientes de corrente, boa estabilidade e alta dispersão. Os resultados bastante satisfatórios demonstram a aplicabilidade dessa técnica em análises em que alta velocidade e boa precisão são freqüentemente requisitadas. / Electrochemical sensors based on bare and modified electrodes were developed for analytical purposes. Copper electrodes exhibited electrocatalytical action for the acetylsalicylic acid oxidation, with the participation of Cu(III) species as electron-transfer mediators. The salbutamol oxidation at glassy carbon electrodes was carried out in strongly alkaline solution. In such a condition, interferences and electrode fouling were eliminated and the analyte quantification was enabled. Glassy carbon surfaces modified via adsorption and electropolymerization of tetraruthenated cobalt (CoTRP) and nickel (NiTRP) porphyrins, respectively, displayed the usefulness of these compounds for the obtainment of electrocatalysis and fouling prevention. Films based on CoTRP, from what Ru(III) are the active sites, were applicable to acetaminophen analysis by facilitating the electron transfer process and protecting the electrode against fouling. The electrocatalytical activity of modified NiTRP electrodes, based on films with Ni(III)/Ni(II) redox centers, was evident for glucose oxidation and other organic compounds. The sensors were coupled to the BIA (batch injection analysis) system for the amperometric determination of the analytes in pharmaceutical products. BIA was suitable because it presented sharp current response peaks, excellent stability and rapid washing out. The satisfactory results demonstrate the feasibility of such technique for fast analyses with good precision.
22

Desenvolvimento de biossensores enzimáticos amperométricos para a determinação de compostos de importância clínica / Development of enzymatic amperometric biosensor for the determination of clinical importancy compounds

Fiorito, Pablo Alejandro 29 November 2005 (has links)
Este trabalho descreve a preparação e caracterização de eletrodos modificados com azul da Prússia e materiais relacionados e a sua aplicação na construção de biossensores enzimáticos amperométricos para a detecção de oxalato e de glicose. Os materiais utilizados na modificação dos eletrodos foram azul da Prússia e compostos híbridos formados por hexacianoferrato de níquel e polipirrol ou hexacianoferrato de cobre e polipirrol. Os materiais lubridos mostraram-se capazes de mediar na eletroredução de peróxido de hidrogênio, mesmo em eletrólitos contendo Na+, apresentando melhor desempenho analítico quando comparados aos respectivos hexacianoferratos sem a presença do polímero condutor. Estes materiais foram utilizados com êxito na construção de biossensores para oxalato e para glicose, imobilizando as enzimas Oxalato Oxidase e Glicose Oxidase, respectivamente. Também foi estudada a preparação de um biossensor para a detecção de glicose utilizando a técnica de automontagem eletrostática camada por camada. Esta técnica permite otimizar o processo de immobilização da enzima, obtendo excelente desempenho analítico com pouca quantidade de enzima. Finalmente, são apresentadas a síntese, caracterização e aplicação de nanopartículas de azul da Prússia na determinação de peróxido de hidrogênio. Foi possível preparar nanopartículas com um diâmetro médio de 5 nm, as quais foram imobilizadas em eletrodos mediante a técnica de automontagem eletrostática camada por camada, a fim de estudar seu comportamento eletroquímico. / This work describes the preparation and characterization of modified electrodes with Prussian blue and some analogues and their application in the development of amperometric enzymatic biosensors for the detection of glucose and oxalate. The materials used in electrode modification were Prussian blue and hybrid compounds, formed by nickel hexacyanoferrate and polypyrrole or copper hexacyanoferrate and polypyrrole. These materials were able to mediate the hydrogen peroxide electroreduction even in electrolytes containing Na+, showing better analytical performance than the hexacyanyoferrates without polypyrrole. These materials were successfully used to build up oxalate and glucose biosensors. We also have studied the preparation of glucose biosensors using the layer by layer self assemble technique (LBL), which has optimized the enzyme immobilization process, obtaining good analytical performances even loading small amounts of enzyme. FinaIly, we have described the synthesis and characterization of Prussian blue nanoparticles by a sonochemical method. It was possible to synthesize nanoparticles with a diameter around 5 nrn, which were immobilized by the LBL technique, in order to study their electrochemical behavior.
23

Estudos eletroquímicos envolvendo eletrodos modificados por metaloporfirinas e aplicação na determinação de nitrato (NO3-) e nitrito (NO2-) / Electrochemical studies involving electrodes modified by metalloporphyrins and application in the determination of nitrate (NO3-) and nitrite (NO2-)

Rocha, José Roberto Caetano da 06 February 2001 (has links)
O presente trabalho inclui duas etapas da pesquisa. Na primeira fase do projeto, a oxidação eletroquímica do nitrito em eletrodo de carbono vítreo modificado com um filme obtido eletrostaticamente de Co-TRP/Zn-TPPS, foi investigada em pH 4,7. Um aumento de corrente foi detectado em 0,75V, cujo máximo foi proporcional à concentração do íons nitrito, exibindo uma dependência inversa com a espessura do filme. A velocidade de transferência de carga foi avaliada por cronoamperometria, sendo que a velocidade de difusão da carga eletroquímica através do filme é mais alta do que a velodicade de difusão do íon em solução. O processo catalítico envolvendo a oxidação do íon nitrito no filme de pares de depósitos alternados foi também investigado com as técnicas da voltametria cíclica e de disco rotativo. Em concentrações relativamente baixas de substrato, o processo mediado foi tratado como um sub-caso, SR, na notação de Saveant, permitindo o cálculo da constante de velocidade para a reação de troca na interface filme-solução, sendo que tal valor foi estimado em 3,4x103 dm3 mol-1 s-1. Na segunda parte da investigação, a potencialidade analítica do eletrodo modificado foi confirmada por experimentos de injeção em fluxo usando solução carregadora tampão pH 4,7. Devido à atividade catalítica da camada imobilizada, a determinação de nitrito foi realizada em potencial menos positivo do que aqueles obtidos em eletrodos polidos (0,75 V vs. Ag/AgCl) e os dados obtidos demostraram o melhor desempenho do eletrodo modificado, indicando excelente repetibilidade e maior sensibilidade. Na condição experimental otimizada, o nitrito foi determinado na configuração FIA com limite de detecção de 0,1 &#181mol L-1 e a faixa analítica de aplicabilidade do método foi de 1 a 1000 µmol L-1. Nitrato também foi quantificado após sua redução estequiométrica a nitrito pela passagem da solução através da coluna de cádmio/cobre. Ambos analitos foram quantificados em água mineral e amostras de saliva e os resultados foram concordantes com aqueles obtidos usando método oficial. / This present work includes two research steps. ln the first step the electrochemical oxidation on nitrite on a glassy carbon disc electrode, modified with an electrostatically assembled film of tetraruthenated cobalt porphyrin/(meso-tetra(4-sulphonatephenyl)porphyrinate zinc(II), was investigated at pH = 4.7. A current enhancement was observed by using the modified electrode, the signal being proportional to the concentration of nitrite ions and exhibiting an inverse dependence with the film thickness. The charge transfer rate was evaluated by chronoamperometry, showing that the rate of diffusion of electrochemical charge through the film is higher than the rate of diffusion of substrates in solution. The catalytic process involving the oxidation of the nitrite ions at the bilayered film was also investigated based on cyclic and rotating disc voltammetry. At relatively low substrate concentrations the mediated process has been dealt with in terms of the SR sub-case in Saveant\'s notation, allowing the calculation of the rate constant for the cross-exchange reaction at the film-solution interface as 3.4x103 dm3 mol-1 s-1. In the second part the analytical potentiality of the modified electrode was studied by flow injection experiments carried out by using a pH 4.7 buffer as carrier solution. Owing to the catalytic activity of the immobilized layer, the determination of nitrite was performed at less positive potentials (0.75 V versus Ag/AgCl) and the data obtained showed a better performance indicated by both an excellent repeatability and increased sensitivity. At the optimized experimental condition, nitrite was determined in the FIA configuration with a limit of detection of 0.1 µmol L-1. Nitrate was also quantified after its stoichiometric reduction to nitrite by passing the solution through a cadmium/copper column. Both analytes were quantified in mineral water and saliva samples and the results were in agreement with the ones obtained by using an official method.
24

Fabricação, caracterização do comportamento eletroquímico e aproveitamento analítico de eletrodos modificados para a determinação de peróxido de hidrogênio / Fabrication, characterization of the electrochemical behavior and analytical use of modified electrodes for the determination of hydrogen peroxide

Roselyn Millaray Castañeda Peña 04 November 2011 (has links)
Neste trabalho são apresentados resultados sobre o desenvolvimento de um sensor visando à utilização no monitoramento de peróxido de hidrogênio em amostras de reações Fenton. Superfícies eletródicas modificadas com filmes de poli-azul de metileno (PMB) e óxido de rutênio de hexacianoferrato (RuOHCF) sem e com a incorporação de nanotubos de carbono de paredes múltiplas (MWCNTs) foram utilizadas para a detecção amperométrica de peróxido de hidrogênio. O efeito da ordem de deposição do PMB e MWCNT foi avaliado por voltametria cíclica e espectroscopia de impedância eletroquímica. Estudos realizados por voltametria cíclica indicaram que a superfície modificada com PBM/MWCNTs facilita a redução catódica do peróxido de hidrogênio, processo que ocorre em 0,0 V vs. Ag/AgCl/KCl(sat). O método para a detecção de peróxido de hidrogênio apresentou uma resposta linear de 109 a 3000 µmol L-1, com limite de detecção de 20,7 µmol L-1 e sensibilidade de 108 µA mmol-1 L cm-2. O eletrodo modificado com RuOHCF foi utilizado para a detecção amperométrica de peróxido de hidrogênio por análise em injeção em fluxo (FIA). O método apresentou uma resposta linear de 10 a 5000 µmol L-1 e limite de detecção de 1,7 µmol L-1. Aplicações em amostras comerciais também foram realizadas, e os resultados foram concordantes com os obtidos por método padrão. Estudos sobre o processo eletrocatalítico da reação de peróxido de hidrogênio em filmes de RuOHCF foram investigados utilizando eletrodo rotativo. A incorporação de MWCNTs na superfície eletródica também foi analisada com o filme de RuOHCF. Os resultados indicaram que a presença de MWCNTs melhorou a resposta do sensor para peróxido de hidrogênio em potenciais próximos a 0,0 V vs. Ag/AgCl/KCl(sat). A influência da quantidade de MWCNTs foi avaliada por amperometria em 0,0 V vs. Ag/AgCl/KCl(sat) na presença de peróxido de hidrogênio. O eletrodo modificado com 100 µg de MWCNTs e posterior deposição do filme de RuOHCF apresentou melhores características analíticas. Obteve-se como resultado uma curva analítica em um intervalo de 0,1 a 10 mmol L-1, originando uma reta de acordo com a equação: -I (µA) = 0,26 + 31,2 [H2O2] (mmol L-1), R2= 0,9999. A sensibilidade foi de 1560 µA mmol-1 L cm-2 e os limites de detecção e quantificação foram estimados em 4,7 (S/N = 3) e 15,8 (S/N = 10) µmol L-1, respectivamente. Comparando-se as características analíticas dos filmes de PMB e RuOHCF depositados na superfície dos MWCNTs, aquele que apresentou melhor resultado foi o eletrodo modificado com MWCNTs e RuOHCF por ter melhor limite de detecção e maior sensibilidade. Esse eletrodo modificado com MWCNTs e RuOHCF foi utilizado para monitorar o consumo de peróxido de hidrogênio em amostras de reação Fenton. Também foi avaliado o efeito da presença de Fe3+ contido no próprio processo de degradação. A interferência foi eliminada complexando o Fe3+ com oxalato. Finalmente, o eletrodo foi utilizado para monitorar a concentração de peróxido de hidrogênio na degradação de fenol e os resultados foram concordantes com os obtidos por método espectrofotométrico / This work presents results on the development of a sensor to monitor the hydrogen peroxide content in samples of Fenton reaction. The electrode surface was modified with films of poly-methylene blue (PMB) and ruthenium oxide hexacyanoferrate (RuOHCF). In some cases, multiwalled carbon nanotubes (MWCNT) were also used. The effect of the order of deposition of PMB and MWCNTs was evaluated by cyclic voltammetry and electrochemical impedance spectroscopy. The influence of immobilization of various platforms in the performance of fabricated sensors for hydrogen peroxide was also studied. Cyclic voltammetry experiments indicated that the surface modified with PMB/MWCNTs facilitates the cathodic reduction of hydrogen peroxide, a process that occurred at 0.0 V vs. Ag/AgCl/KCl(sat). The method showed a linear response from 109 to 3000 µmol L-1 hydrogen peroxide. The limit of detection was estimated as 20.7 (S/N = 3) µmol L-1 with a sensitivity of 108 µA mmol-1 L cm-2. Electrodes modified with RuOHCF films were used for the amperometric detection of hydrogen peroxide by flow injection analysis (FIA).The method showed a linear response from 10 to 5000 µmol L-1 and a detection limit of 1.7 µ mol L-1. Analyses of hydrogen peroxide in commercial samples were also performed, and the results agreed with those obtained by a standard method. Studies on the kinetics of the electrocatalytic reduction of hydrogen peroxide in RuOHCF films were carried out using rotating disc voltammetric. The immobilization of MWCNTs on RuOHCF films was also investigated. The results indicated that the presence of MWCNTs facilitated the electrocatalytic reduction of hydrogen peroxide at potential values near to 0.0 V vs. vs. Ag/AgCl/KCl(sat). The influence of the amount of MWCNTs was studied by amperometry at 0.0 V vs. vs. Ag/AgCl/KCl(sat) in the presence of hydrogen peroxide. The electrode modified with 100 µg of MWCNTs and subsequent deposition of the RuOHCF film showed better analytical characteristics. An analytical curve ranging from 0.1 to 10 mmol L-1 hydrogen peroxide was obtained, resulting in a straight line according to the equation: -I (µA) = 0.26 + 31.2 [H2O2] (mmol L-1), R2= 0.9999. The sensitivity was found to be 1560 µA mmol-1 L cm-2 and the detection and quantification limits were estimated at 4.7 (S / N = 3) and 15.8 (S / N = 10) mmol L-1, respectively. Electrodes modified with MWCNTs and RuOHCF films leaded to better detection limit and sensitivity in comparison to those modified with MWCNTs and PMB. This MWCNTs and RuOHCF modified electrode was used to monitor the consumption of hydrogen peroxide in samples of Fenton reaction and the effect of Fe3+ generated in the degradation process was also examined. The interference was minimized by adding oxalate to the samples. Finally, the sensor was used to monitor the concentration of hydrogen peroxide in the degradation of phenol and the results were in agreement with those obtained by using spectrophotometry
25

Estudos eletroquímicos envolvendo eletrodos modificados por metaloporfirinas e aplicação na determinação de nitrato (NO3-) e nitrito (NO2-) / Electrochemical studies involving electrodes modified by metalloporphyrins and application in the determination of nitrate (NO3-) and nitrite (NO2-)

José Roberto Caetano da Rocha 06 February 2001 (has links)
O presente trabalho inclui duas etapas da pesquisa. Na primeira fase do projeto, a oxidação eletroquímica do nitrito em eletrodo de carbono vítreo modificado com um filme obtido eletrostaticamente de Co-TRP/Zn-TPPS, foi investigada em pH 4,7. Um aumento de corrente foi detectado em 0,75V, cujo máximo foi proporcional à concentração do íons nitrito, exibindo uma dependência inversa com a espessura do filme. A velocidade de transferência de carga foi avaliada por cronoamperometria, sendo que a velocidade de difusão da carga eletroquímica através do filme é mais alta do que a velodicade de difusão do íon em solução. O processo catalítico envolvendo a oxidação do íon nitrito no filme de pares de depósitos alternados foi também investigado com as técnicas da voltametria cíclica e de disco rotativo. Em concentrações relativamente baixas de substrato, o processo mediado foi tratado como um sub-caso, SR, na notação de Saveant, permitindo o cálculo da constante de velocidade para a reação de troca na interface filme-solução, sendo que tal valor foi estimado em 3,4x103 dm3 mol-1 s-1. Na segunda parte da investigação, a potencialidade analítica do eletrodo modificado foi confirmada por experimentos de injeção em fluxo usando solução carregadora tampão pH 4,7. Devido à atividade catalítica da camada imobilizada, a determinação de nitrito foi realizada em potencial menos positivo do que aqueles obtidos em eletrodos polidos (0,75 V vs. Ag/AgCl) e os dados obtidos demostraram o melhor desempenho do eletrodo modificado, indicando excelente repetibilidade e maior sensibilidade. Na condição experimental otimizada, o nitrito foi determinado na configuração FIA com limite de detecção de 0,1 &#181mol L-1 e a faixa analítica de aplicabilidade do método foi de 1 a 1000 µmol L-1. Nitrato também foi quantificado após sua redução estequiométrica a nitrito pela passagem da solução através da coluna de cádmio/cobre. Ambos analitos foram quantificados em água mineral e amostras de saliva e os resultados foram concordantes com aqueles obtidos usando método oficial. / This present work includes two research steps. ln the first step the electrochemical oxidation on nitrite on a glassy carbon disc electrode, modified with an electrostatically assembled film of tetraruthenated cobalt porphyrin/(meso-tetra(4-sulphonatephenyl)porphyrinate zinc(II), was investigated at pH = 4.7. A current enhancement was observed by using the modified electrode, the signal being proportional to the concentration of nitrite ions and exhibiting an inverse dependence with the film thickness. The charge transfer rate was evaluated by chronoamperometry, showing that the rate of diffusion of electrochemical charge through the film is higher than the rate of diffusion of substrates in solution. The catalytic process involving the oxidation of the nitrite ions at the bilayered film was also investigated based on cyclic and rotating disc voltammetry. At relatively low substrate concentrations the mediated process has been dealt with in terms of the SR sub-case in Saveant\'s notation, allowing the calculation of the rate constant for the cross-exchange reaction at the film-solution interface as 3.4x103 dm3 mol-1 s-1. In the second part the analytical potentiality of the modified electrode was studied by flow injection experiments carried out by using a pH 4.7 buffer as carrier solution. Owing to the catalytic activity of the immobilized layer, the determination of nitrite was performed at less positive potentials (0.75 V versus Ag/AgCl) and the data obtained showed a better performance indicated by both an excellent repeatability and increased sensitivity. At the optimized experimental condition, nitrite was determined in the FIA configuration with a limit of detection of 0.1 µmol L-1. Nitrate was also quantified after its stoichiometric reduction to nitrite by passing the solution through a cadmium/copper column. Both analytes were quantified in mineral water and saliva samples and the results were in agreement with the ones obtained by using an official method.
26

Filmes nanoestruturados de materiais de interesse biológico: ênfase na interação com modelos de membrana e aplicações em biossensores / Nanostructured films with materials of biological interest: emphasis on interaction with membrane models and biosensor applications

Moraes, Marli Leite de 27 August 2008 (has links)
A imobilização de moléculas de interesse biológico em superfícies sólidas é essencial para uma série de aplicações biotecnológicas. Dentre as técnicas de imobilização, a automontagem camada por camada por adsorção física possui inúmeras vantagens, incluindo condições brandas e fisiológicas de preparação, capacidade de incorporar diferentes biomoléculas, e controle molecular. Nesta tese foram explorados filmes nanoestruturados de materiais de interesse biológico, bem como modelos de membranas, em que foram empregadas a técnica de automontagem e a preparação de lipossomos. Os lipossomos, que serviram como modelos de membrana, foram imobilizados em filmes automontados e sua integridade estrutural foi mantida. Também foram utilizados para incorporar e estabilizar melanina, e então imobilizados em filmes automontados, com preservação da propriedade fluorescente da melanina. A automontagem também foi utilizada para imobilização das enzimas uricase, fitase e colesterol oxidase, alternadas com camadas de polieletrólitos. Estes filmes mostraram bom desempenho como biossensores amperométricos para uricase e fitase, e como biossensores usando espectroscopia de impedância para a fitase e colesterol oxidase. Tais biossensores foram usados para detectar baixas quantidades de ácido úrico, ácido fítico e colesterol, respectivamente. Não houve efeitos de interferentes nos sensores amperométricos devido à utilização de eletrodos previamente modificados com azul da Prússia, que funcionou como mediador redox. A alta sensibilidade e seletividade dos biossensores foram atribuídas à natureza do filme ultrafino e à capacidade de reconhecimento das biomoléculas, respectivamente. Esta abordagem abre caminho para novas tecnologias de dispositivos para diagnósticos clínicos e análises de alimentos, bem como para entender mecanismos de interação da biomolécula com a membrana celular para o desenvolvimento de agentes terapêuticos. / The immobilization of molecules of biological interest on solid surfaces is essential for a number of biotechnological applications. Among the techniques for immobilization the layer-by-layer (LbL) method based on physical adsorption exhibits several advantages, including mild, physiological conditions for film preparation, ability to incorporate different biomolecules and molecular control. In this thesis, nanostructured films made with materials of biological interest were exploited as model membranes, where use was made of the LbL technique and liposomes. The latter, which served as membrane models, were immobilized in LbL films and had their structural integrity preserved. Liposomes were also used to incorporate and stabilize melanin, which were then deposited on LbL films with the fluorescence of melanin being preserved. The LbL method was also used to immobilize the enzymes uricase, phytase and cholesterol oxidase, alternated with layers of polyelectrolytes. These LbL films were employed in amperometric biosensors with uricase and phytase, and in biosensors based on impedance spectroscopy for phytase and cholesterol oxidase. Low amounts of uric acid, phytic acid and cholesterol were detected, respectively. There was no effect from interferents in the amperometric biosensors because the electrodes were previously modified with a layer of Prussian Blue, which acted as a redox mediator. The high sensitivity and selectivity were attributed to the ultrathin nature of the films and the ability of molecular recognition of the biomolecules, respectively. The approaches used here open the way for novel devices for clinical diagnostics and food quality control, in addition to understanding the interaction mechanisms between the biomolecules and the cell membranes, which is important for developing therapeutic agents.
27

Fabricação, caracterização do comportamento eletroquímico e aproveitamento analítico de eletrodos modificados para a determinação de peróxido de hidrogênio / Fabrication, characterization of the electrochemical behavior and analytical use of modified electrodes for the determination of hydrogen peroxide

Peña, Roselyn Millaray Castañeda 04 November 2011 (has links)
Neste trabalho são apresentados resultados sobre o desenvolvimento de um sensor visando à utilização no monitoramento de peróxido de hidrogênio em amostras de reações Fenton. Superfícies eletródicas modificadas com filmes de poli-azul de metileno (PMB) e óxido de rutênio de hexacianoferrato (RuOHCF) sem e com a incorporação de nanotubos de carbono de paredes múltiplas (MWCNTs) foram utilizadas para a detecção amperométrica de peróxido de hidrogênio. O efeito da ordem de deposição do PMB e MWCNT foi avaliado por voltametria cíclica e espectroscopia de impedância eletroquímica. Estudos realizados por voltametria cíclica indicaram que a superfície modificada com PBM/MWCNTs facilita a redução catódica do peróxido de hidrogênio, processo que ocorre em 0,0 V vs. Ag/AgCl/KCl(sat). O método para a detecção de peróxido de hidrogênio apresentou uma resposta linear de 109 a 3000 µmol L-1, com limite de detecção de 20,7 µmol L-1 e sensibilidade de 108 µA mmol-1 L cm-2. O eletrodo modificado com RuOHCF foi utilizado para a detecção amperométrica de peróxido de hidrogênio por análise em injeção em fluxo (FIA). O método apresentou uma resposta linear de 10 a 5000 µmol L-1 e limite de detecção de 1,7 µmol L-1. Aplicações em amostras comerciais também foram realizadas, e os resultados foram concordantes com os obtidos por método padrão. Estudos sobre o processo eletrocatalítico da reação de peróxido de hidrogênio em filmes de RuOHCF foram investigados utilizando eletrodo rotativo. A incorporação de MWCNTs na superfície eletródica também foi analisada com o filme de RuOHCF. Os resultados indicaram que a presença de MWCNTs melhorou a resposta do sensor para peróxido de hidrogênio em potenciais próximos a 0,0 V vs. Ag/AgCl/KCl(sat). A influência da quantidade de MWCNTs foi avaliada por amperometria em 0,0 V vs. Ag/AgCl/KCl(sat) na presença de peróxido de hidrogênio. O eletrodo modificado com 100 µg de MWCNTs e posterior deposição do filme de RuOHCF apresentou melhores características analíticas. Obteve-se como resultado uma curva analítica em um intervalo de 0,1 a 10 mmol L-1, originando uma reta de acordo com a equação: -I (µA) = 0,26 + 31,2 [H2O2] (mmol L-1), R2= 0,9999. A sensibilidade foi de 1560 µA mmol-1 L cm-2 e os limites de detecção e quantificação foram estimados em 4,7 (S/N = 3) e 15,8 (S/N = 10) µmol L-1, respectivamente. Comparando-se as características analíticas dos filmes de PMB e RuOHCF depositados na superfície dos MWCNTs, aquele que apresentou melhor resultado foi o eletrodo modificado com MWCNTs e RuOHCF por ter melhor limite de detecção e maior sensibilidade. Esse eletrodo modificado com MWCNTs e RuOHCF foi utilizado para monitorar o consumo de peróxido de hidrogênio em amostras de reação Fenton. Também foi avaliado o efeito da presença de Fe3+ contido no próprio processo de degradação. A interferência foi eliminada complexando o Fe3+ com oxalato. Finalmente, o eletrodo foi utilizado para monitorar a concentração de peróxido de hidrogênio na degradação de fenol e os resultados foram concordantes com os obtidos por método espectrofotométrico / This work presents results on the development of a sensor to monitor the hydrogen peroxide content in samples of Fenton reaction. The electrode surface was modified with films of poly-methylene blue (PMB) and ruthenium oxide hexacyanoferrate (RuOHCF). In some cases, multiwalled carbon nanotubes (MWCNT) were also used. The effect of the order of deposition of PMB and MWCNTs was evaluated by cyclic voltammetry and electrochemical impedance spectroscopy. The influence of immobilization of various platforms in the performance of fabricated sensors for hydrogen peroxide was also studied. Cyclic voltammetry experiments indicated that the surface modified with PMB/MWCNTs facilitates the cathodic reduction of hydrogen peroxide, a process that occurred at 0.0 V vs. Ag/AgCl/KCl(sat). The method showed a linear response from 109 to 3000 µmol L-1 hydrogen peroxide. The limit of detection was estimated as 20.7 (S/N = 3) µmol L-1 with a sensitivity of 108 µA mmol-1 L cm-2. Electrodes modified with RuOHCF films were used for the amperometric detection of hydrogen peroxide by flow injection analysis (FIA).The method showed a linear response from 10 to 5000 µmol L-1 and a detection limit of 1.7 µ mol L-1. Analyses of hydrogen peroxide in commercial samples were also performed, and the results agreed with those obtained by a standard method. Studies on the kinetics of the electrocatalytic reduction of hydrogen peroxide in RuOHCF films were carried out using rotating disc voltammetric. The immobilization of MWCNTs on RuOHCF films was also investigated. The results indicated that the presence of MWCNTs facilitated the electrocatalytic reduction of hydrogen peroxide at potential values near to 0.0 V vs. vs. Ag/AgCl/KCl(sat). The influence of the amount of MWCNTs was studied by amperometry at 0.0 V vs. vs. Ag/AgCl/KCl(sat) in the presence of hydrogen peroxide. The electrode modified with 100 µg of MWCNTs and subsequent deposition of the RuOHCF film showed better analytical characteristics. An analytical curve ranging from 0.1 to 10 mmol L-1 hydrogen peroxide was obtained, resulting in a straight line according to the equation: -I (µA) = 0.26 + 31.2 [H2O2] (mmol L-1), R2= 0.9999. The sensitivity was found to be 1560 µA mmol-1 L cm-2 and the detection and quantification limits were estimated at 4.7 (S / N = 3) and 15.8 (S / N = 10) mmol L-1, respectively. Electrodes modified with MWCNTs and RuOHCF films leaded to better detection limit and sensitivity in comparison to those modified with MWCNTs and PMB. This MWCNTs and RuOHCF modified electrode was used to monitor the consumption of hydrogen peroxide in samples of Fenton reaction and the effect of Fe3+ generated in the degradation process was also examined. The interference was minimized by adding oxalate to the samples. Finally, the sensor was used to monitor the concentration of hydrogen peroxide in the degradation of phenol and the results were in agreement with those obtained by using spectrophotometry
28

Determinação simultânea de propifenazona, paracetamol e cafeína utilizando eletrodo de diamante dopado com boro

Silva, Weberson Pereira da 16 February 2017 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / No presente trabalho investigou-se o desenvolvimento de novos procedimentos analíticos para a determinação simultânea de paracetamol (PAR), propifenazona (PRO) e cafeína (CAF) em formulações farmacêuticas. Três métodos foram desenvolvidos usando as técnicas de voltametria de onda quadrada (SWV) e amperometria de múltiplos pulsos (MPA) e diamante dopado com boro (BDD) como eletrodo de trabalho. Empregando a SWV, duas estratégias de análise foram desenvolvidas: (I) uso de uma célula eletroquímica convencional (modo estacionário) e o método de adição de padrão; (II) uso de análise por injeção em batelada com detecção por voltametria de onda quadrada (BIA-SWV) e o método de calibração externa. Os métodos propostos foram desenvolvidos usando como eletrólito de suporte H2SO4 0,1 mol L-1 e os parâmetros otimizados da SWV foram: potencial de condicionamento: -1,5 V durante 20 s; frequência: 60 s-1; amplitude: 50 mV e incremento de potencial: 4 mV. No método proposto empregando BIA-SWV, o volume e a velocidade de injeção otimizados foram de 100 μL e 28 μL s-1, respectivamente. Um terceiro método proposto para determinação simultânea de PAR, PRO e CAF, o procedimento de análise por injeção em batelada com detecção por amperometria de múltiplos pulsos (BIA-MPA) foi empregado. Três pulsos de potenciais foram selecionados para realização da análise: +0,90 V /50 ms: apenas o PAR foi oxidado sem a interferência dos outros dois compostos; +1,20 V /50 ms: oxidação do PAR e da PRO livre da interferência da CAF; +1,60 V /50 ms: oxidação dos três compostos (PAR, PRO e CAF). A seletividade na detecção da PRO e CAF foi obtida mediante subtração de correntes entre os amperogramas adquiridos nos potenciais selecionados e o uso de fatores de correção (FCs). Todos os procedimentos de análise desenvolvidos mostraram-se estáveis (DPR < 4,1%) e lineares (r > 0,997). O método empregando uma célula eletroquímica convencional apresentou frequência analítica de 20 análises h-1 e limites de detecção de 0,005, 0,009 e 0,006 mg L-1 para PAR, PRO e CAF, respectivamente. Os métodos BIA-SWV e BIA-MPA apresentaram frequência analítica muito superior: 80 e 75 análises h-1, respectivamente. Os limites de detecção foram de 0,3, 0,2 e 0,3 mg L-1 (BIA-SWV) e 0,2, 0,3 e 0,1 mg L-1 (BIA-MPA) para PAR, PRO e CAF, respectivamente. / In this work we investigated the development of new analytical procedures for simultaneous determination of paracetamol (PAR), propyphenazone (PRO) and caffeine (CAF) in pharmaceutical formulations. Three methods was developed using of Square wave voltammetry (SWV), multiple pulse amperometry (MPA) and boron doped diamond (BDD) with work electrode. Employing SWV, two analysis strategies were developed (I) Use of a conventional electrochemical cell (stationary mode) and the standard addition method; (II) use of batch injection analysis with detection by square wave voltammetry (BIA-SWV) and external calibration method. The proposed methods were developed using H2SO4 0.1 mol L-1 as supporting electrolyte and optimized parameters of the SWV: Conditioning potential: -1.5 V during 20 s; frequency: 60 s-1; amplitude: 50 mV and step potential: 4 mV. In the proposed method using BIA-SWV, volume and speed of optimized injection were 100 μL e 28 μL s-1, respectively. On the third method proposed for simultaneous determination of the PAR, PRO and CAF, the batch injection analysis procedure with multiple pulse amperometry detection (BIA-MPA) was employed. Three potentials pulses were selected for the analysis: +0.90 V/50 ms: only PAR was oxidized without the interference of the other two compounds; +1.20 V/50 ms: oxidation PAR and PRO without the interference of the CAF; +1.60 V/50 ms: oxidation of the three compounds (PAR, PRO and CAF). The selectivity in the detection of PRO and CAF was obtained by subtracting currents between the amperograms acquired in the selected potentials and the use of correction factors (CFs). All developed analysis procedures remained stable (RSD < 4.1%) and linear (r > 0.997). The method using a conventional electrochemical cell showed an analytical frequency of 20 analysis h-1 and limits of detection of 0.005, 0.009, and 0.006 mg L-1 for PAR, PRO, and CAF, respectively. The BIA-SWV and BIA-MPA methods presented higher analytical frequency: 80 and 75 analysis h-1, respectively. The limits of detection were 0.3, 0.2, and 0.3 mg L-1 (BIA-SWV) and 0.2, 0.3, and 0.1 mg L-1 (BIA-MPA) for PAR, PRO and CAF, respectively. / Dissertação (Mestrado)
29

Determina??o de sildenafila (Viagra?) e carbamazepina em formula??es farmac?uticas por amperometria de m?ltiplos pulsos em sistema FIA / Determination of sildenafil (Viagra?) and carbamazepine in pharmaceutical formulations by multiple pulses amperometry in FIA system

Lopes J?nior, Ant?nio Carlos Vieira 27 July 2012 (has links)
Submitted by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-02-19T13:03:28Z No. of bitstreams: 5 carlos.pdf: 2538374 bytes, checksum: bc72a52cc529db58b3cf890bd9a41042 (MD5) license_url: 52 bytes, checksum: 3d480ae6c91e310daba2020f8787d6f9 (MD5) license_text: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) license.txt: 2110 bytes, checksum: b4c884761e4c6c296ab2179d378436d4 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-02-20T09:21:34Z (GMT) No. of bitstreams: 5 license.txt: 2110 bytes, checksum: b4c884761e4c6c296ab2179d378436d4 (MD5) carlos.pdf: 2538374 bytes, checksum: bc72a52cc529db58b3cf890bd9a41042 (MD5) license_url: 52 bytes, checksum: 3d480ae6c91e310daba2020f8787d6f9 (MD5) license_text: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2015-02-20T09:21:34Z (GMT). No. of bitstreams: 5 license.txt: 2110 bytes, checksum: b4c884761e4c6c296ab2179d378436d4 (MD5) carlos.pdf: 2538374 bytes, checksum: bc72a52cc529db58b3cf890bd9a41042 (MD5) license_url: 52 bytes, checksum: 3d480ae6c91e310daba2020f8787d6f9 (MD5) license_text: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2013-02-21 / O presente trabalho apresenta m?todos simples, r?pidos e de baixo custo para determina??o de citrato de sildenafila (CS) e carbamazepina (CBZ) em formula??es farmac?uticas atrav?s da detec??o amperom?trica de m?ltiplos pulsos (MPA) em sistema de an?lise por inje??o em fluxo (FIA) utilizando como eletrodo de trabalho o diamante dopado com boro (DDB). O m?todo para determina??o de CS consiste na aplica??o de tr?s pulsos de potencial em sequ?ncia. Os pulsos de potencial de 1,6 V e 1,9 V s?o utilizados para detec??o eletroqu?mica do f?rmaco e um terceiro pulso de potencial (1,0 V) para promover a limpeza e reativa??o da superf?cie do eletrodo de DDB. Os limites de detec??o (LD) obtido nas condi??es estabelecidas est?o na ordem de 10 nmol L-1 para ambos os potenciais de detec??o. O desvio padr?o relativo das respostas de 10 inje??es consecutivas de CS na concentra??o de 4,5x10-5 mol L-1 foi de 0,1 e 0,2% para os pulsos de potencial de detec??o de 1,9 V e 1,6 V, respectivamente. Os estudos de adi??o e recupera??o de CS padr?o foram realizados em todas as amostras farmac?uticas apresentando recupera??o, em todos os casos, pr?ximo de 100%. Os resultados de doseamento dos medicamentos realizados a partir do m?todo proposto foram validados por metodologia cromatogr?fica. Para a CBZ foram propostas duas vertentes anal?ticas, uma voltada para determina??o do ativo em amostras farmac?uticas e outra para detec??o do f?rmaco em fluidos biol?gicos. Alguns par?metros foram semelhantes em ambos os procedimentos, s?o eles: eletr?lito suporte (?cido sulf?rico 0,2 mol L-1), vaz?o (3,0 mL min-1), volume de amostragem (150 ?L), potencial de limpeza (-1,4 V) e tempo de aplica??o deste potencial (600 ms). Al?m destes par?metros, para an?lise do f?rmaco em produto farmac?utico, foram utilizados para detec??o os pulsos de potenciais 1,6 e -1,2V, sendo aplicados por 150 e 30 ms, respectivamente. Nestas condi??es, foram obtidas as seguintes faixas lineares de trabalho: 0,6 a 40,0 ?mol L-1 para o pulso de potencial de 1,6 V e 0,4 a 20,0 ?mol L-1 para o pulso de potencial de -1,2 V. Para determina??o de CBZ em fluido biol?gico adotou-se como sistema de detec??o o pulso de potencial de 1,6 V aplicado por 800 ms (gerador) e o pulso de potencial de -1,2 V aplicado por 30 ms (detector). Para este pulso de potencial foi obtida faixa linear de trabalho de 0,02 a 1,0 ?mol L-1 e LD de 1,78 nmol L-1. Os estudos de adi??o e recupera??o de CBZ padr?o em amostras farmac?uticas e urina apresentaram resultados pr?ximos de 100%. Os resultados do ensaio de doseamento de medicamentos, realizados pelo m?todo proposto, foram validados por meio de metodologia oficial. Este trabalho apresenta, pela primeira vez, m?todos para determina??o de CS e CBZ em formula??es farmac?uticas atrav?s da detec??o MPA em sistema FIA. A associa??o desta t?cnica ao eletrodo de trabalho de DDB permitiu o desenvolvimento de m?todos de elevada sensibilidade, seletividade, rapidez e reprodutibilidade, demonstrando not?vel potencialidade para aplica??o no controle de qualidade de rotina de CS e CBZ em laborat?rios farmac?uticos e farm?cias de manipula??o. / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Qu?mica, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2012. / ABSTRACT The present work presents simple, fast and low-cost methods for determination of sildenafil citrate (CS) and carbamazepine (CBZ) in pharmaceutical formulations using flow injection analysis (FIA) with multiple pulse amperometric (MPA) detection on the boron-doped diamond (DDB) working electrode. The method for the CS determination consists of the application of three sequential potential pulses as function of the time. SC is detected at 1.6 V and 1.9 V by two different irreversible oxidation processes. The third potential pulse (1.0 V) is applied for the regeneration (cleaning) of the electrode (boron-doped diamond) surface. The limit of detection (LD) in an order of 10 nmol L-1 was reached with a standard deviation of less than 0.2 % (n = 10) for 4.5 x 10-5 mol L-1 CS. The analytical frequency was calculated in 86 injections per hour. The addition-recovery studies in all the samples were around 100% and the results were validated by chromatographic methods. For the CBZ determination, two analytic conditions were proposed, one used for determination of a drug in pharmaceutical samples and other for detection the active ingredient in biological fluids. Some parameters were similar in both procedures, they are: supporting electrolyte (sulfuric acid 0.2 mol L-1), flow (3.0 ml min-1), sampling volume (150 ?L), regeneration potential pulse (-1.4 V) and time of application of this potential (600 ms). In addition to these parameters, for analysis of pharmaceutical drug, were used to detect it the potential pulses 1.6 V and -1.2 V, being applied for 150 and 30 ms, respectively. These conditions provided linear range of 0.6 to 40.0 ?mol L -1 for potential pulse 1.6 V and 0.4 to 20.0 ?mol L-1 for potential pulse -1.2 V. For the CBZ determination in biological fluid adopted as detection system the potential pulse of 1.6 V applied for 800 ms (generator) and potential pulse of -1.2 V applied for 30 ms (detector). For this potential pulse the linear range was of 0.02 to 1.0 ?mol L-1 and the LD was 1.78 nmol L-1. The addition-recovery studies in all the samples were around 100 % and the results were validated by official method. This work presents for the first time methods of SC and CBZ determination in pharmaceutical formulations utilizing MPA detection coupled to an FIA system. This technique, associated with a BDD working electrode, provided a sensitive, selective, fast and highly reproducible methods. Thus, the proposed methods may be an extremely attractive alternative for routine large and small-scale CS and CBZ analysis.
30

Determina??o de colchicina em formula??es farmac?uticas e urina por amperometria de m?ltiplos pulsos em sistema FIA usando eletrodo de diamante dopado com boro / determination of colchicine in pharmaceutical formulations and urine by multiple-pulse amperometric in FIA system using boron-doped diamond electrode

Moreira, D?bora Aparecida Rocha 23 July 2015 (has links)
?rea de concentra??o: Qu?mica Anal?tica. / Submitted by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2016-01-06T17:04:45Z No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) debora_aparecida_rocha_moreira.pdf: 1871735 bytes, checksum: 71403ce90b6b32e48e7c18b312d74e32 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2016-01-07T11:59:23Z (GMT) No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) debora_aparecida_rocha_moreira.pdf: 1871735 bytes, checksum: 71403ce90b6b32e48e7c18b312d74e32 (MD5) / Made available in DSpace on 2016-01-07T11:59:23Z (GMT). No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) debora_aparecida_rocha_moreira.pdf: 1871735 bytes, checksum: 71403ce90b6b32e48e7c18b312d74e32 (MD5) Previous issue date: 2015 / A colchicina (CO) ? um medicamento utilizado no tratamento da artrite gotosa com a??o anti-inflamat?ria. Este medicamento pertence a uma classe de compostos chamados de baixo ?ndice terap?utico, cuja dose t?xica ? muito pr?xima da dose terap?utica. Assim, a determina??o de CO em formula??es farmac?uticas e em fluidos biol?gicos ? de maior import?ncia para o controle de qualidade nos estudos farmac?uticos e farmacol?gicos na condu??o da elimina??o da droga. Neste contexto, o presente trabalho apresenta m?todos simples, r?pidos e de baixos custos para determina??o de CO em formula??es farmac?uticas e urina por amperometria de m?ltiplos pulsos (MPA) com an?lise de inje??o em fluxo, sistema (FIA), usando eletrodo de diamante dopado com boro (BDD). O estudo foi realizado em diferentes eletr?litos, Britton-Robinson de pH que variou de 2 a 12, solu??o de hidr?xido de s?dio e ?cido sulf?rico, ambos na concentra??o de 0,1 mol L-1. As melhores condi??es para o eletr?lito de suporte foi em ?cido sulf?rico 0,1 mol L-1, em que a CO apresentou processos de oxida??o em 1,20 e 1,41 V e uma redu??o de detec??o em -0,9 V. MPA foi baseado na aplica??o potencial dos dois impulsos de: (1) para a oxida??o de CO e (2) para a redu??o do produto gerado, o qual foi utilizado para a determina??o das amostras de f?rmacos. Assim, no sistema FIA-MPA foram aplicados pulsos potenciais de 1,7 V / 500 ms e -1,1V / 30 ms. Os demais par?metros foram otimizados como: taxa de fluxo e volume da amostra em 4,5 mL min-1 e 330 ?L, respectivamente. Sob estas condi??es, foi obtida duas faixas lineares de 0,1 ? 2,0 ? mol L-1 e 20 x 10-5 a 500 x 10-4 mol L-1 com coeficiente de correla??o linear de 0,992 e 0,998, respectivamente. O limite de detec??o obtido foi de 2,14 x 10-8 mol L-1 para o CO. O desvio padr?o relativo de inje??es consecutivas de 10 respostas sobre a concentra??o de CO de 1,0 x 10-4 mol L-1 foi de 1,28% em -1.1 V. O sistema foi validado em compara??o com o m?todo oficial (HPLC / UV). Os resultados das recupera??es obtidas por meio do m?todo proposto para ambas as amostras foram pr?ximo a 100%. Portanto, o m?todo proposto por FIA-MPA utilizando eletrodo BDD pode ser aplicado com sucesso para a determina??o de CO em amostras de urina e farmac?uticas, com vantagens em rela??o ao m?todo oficial e outros m?todos descritos na literatura. / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Qu?mica, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2015. / ABSTRACT The Colchicine (CO) is a drug used in treatment of gouty arthritis with anti-inflammatory action. This medication belongs to a class of compounds called low therapeutic index, whose toxic dose is much close to the therapeutic dose. Thus, the determination of CO in pharmaceutical formulations and in biological fluids is of the utmost importance for the quality control in pharmaceutical and pharmacological studies in conducting the elimination of the drug. In this context, the present work presents simple, fast and low-cost methods for determination of CO in pharmaceutical formulations and urine by multiple-pulse amperometric (MPA) with flow-injection analysis (FIA) system using boron-doped diamond (BDD) electrode. Study was carried out in different electrolytes, Britton-Robinson buffer pH ranging from 2 to 12, sodium hydroxide solution and sulfuric acid, both at a concentration of 0.1 mol L-1. The best conditions for the support electrolyte was sulfuric acid 0.1 mol L-1, where the CO showed oxidation processes at 1.20 and 1.41 V and one of reduction at -0.9 V. MPA detection was based on the potential application of two pulses: (1) for oxidation of CO and (2) for reduction in the generated product, which was used for the determination of the drug in the samples. Thus, in the FIA-MPA system were applied potential pulses of 1.7 V / 500ms and -1.1V / 30ms. The other parameters were optimized as: flow rate and sample volume in 4.5 mL min-1 and 330 ?L, respectively. Under these conditions, it was achieved two linear ranges of 0.1 to 2.0 ?mol L-1 and of 20 to 500 ?mol L-1 with great linear correlation coefficient for both ranges 0.992 and 0.998 respectively. The limit of detection obtained was of 2.14 x 10-8 mol L-1 for CO. Relative standard deviation of injections of 10 consecutive responses on CO concentration of 1.0 x 10-4 mol L-1 was 1.28% at -1.1 V. The system was validated in comparison with the official method (HPLC / UV). The results of the recoveries obtained through the proposed method for both samples are around 100%. Therefore, the method proposed by FIA-MPA using BDD electrode can be successfully applied for the determination of CO in pharmaceutical and urine samples, with advantages in relationship official method and others methods described in the literature.

Page generated in 0.068 seconds