• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 360
  • 9
  • 4
  • Tagged with
  • 381
  • 322
  • 183
  • 162
  • 159
  • 137
  • 82
  • 77
  • 67
  • 65
  • 60
  • 58
  • 50
  • 48
  • 46
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Validade do modelo distância-tempo para a determinação das capacidades aeróbia e anaeróbia em jogadores de futebol

Gomide, Euripedes Barsanulfo Gonçalves [UNESP] 17 February 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:53Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-02-17Bitstream added on 2014-06-13T18:08:42Z : No. of bitstreams: 1 gomide_ebg_me_rcla.pdf: 225388 bytes, checksum: 0c45dfdc91fa2eca917ae59d17217846 (MD5) / Universidade Estadual Paulista (UNESP) / Os objetivos deste estudo foram verificar: a) a validade do limiar anaeróbio (LAn) e da velocidade crítica (VC) para estimar a máxima fase estável de lactato (MSSLAC) em jogadores de futebol e; b) a validade da capacidade de trabalho anaeróbio (CTAn) em estimar a capacidade anaeróbia em jogadores de futebol. Participaram deste estudo, 31 jogadores de futebol do sexo masculino, divididos em dois grupos: Grupo I - composto por 13 indivíduos (21,4 + 1,04 anos de idade, 1,77 + 0,06 m de altura, 70,9 + 8,18 kg de peso corporal, 22,4 + 1,5 kg/m2 de IMC e 12,0 + 2,1 % de gordura corporal) e Grupo II - composto por 18 indivíduos (16,8 + 1,26 anos de idade, 1,80 + 0,05 m de altura, 67,9 + 6,16 kg de peso corporal, 21,5 + 1,5 kg/m2 de IMC e 11,7 + 1,5 % de gordura corporal). Os atletas do Grupo I realizaram os seguintes testes: 1) teste incremental na esteira rolante para a determinação do LAn. A velocidade correspondente ao LAn (3,5 mM) foi determinada por interpolação linear; 2) teste de carga constante - A MSSLAC foi determinada a partir de 3 a 5 testes de carga constante com até 30 min de duração e foi definida com sendo a maior velocidade na qual a concentração de lactato não aumentou mais do que 1 mM entre o 100 e o 300 min do teste, e; 3) VC - Os atletas realizaram dois tiros máximos de 1500 e 3000 m em uma pista de atletismo de 400 m. A VC foi determinada como sendo a inclinação de regressão linear entre a distância e o tempo. Os atletas do Grupo II realizaram os seguintes testes: 1) CTAn - Os atletas realizaram dois tiros máximos de 1500 e 3000 m em uma pista de atletismo de 400 m. A CTAn foi determinada como sendo o intercepto da reta de regressão linear entre a distância e o tempo, e; 2) Teste de Wingate (TW) - O TW foi realizado contra uma resistência de 0,090 kp/kg. A potência máxima (Pmax) e trabalho total (TT) foram a maior potência... (Complete abstract, click electronic address below). / The objectives of this study were to analyze: a) the validity of the speed corresponding to the anaerobic threshold (AT) and critical velocity (CV) to determine the maximal lactate steady state (MSSLAC) in soccer players and; b) the validity of anaerobic work capacity (AWC) to estimate the anaerobic capacity in soccer players. Participated of this study, 31 male soccer players, divided into two groups: Group I - 13 individuals (21.4 + 1.04 yr, 1.77 + 0.06 m, 70.9 + 8.18 kg, 22.4 + 1.5 kg/m2 and 12.0 + 2.1 % body fat) and Group II - 18 individuals (16.8 + 1.26 yr, 1.80 + 0.05 m, 67.9 + 6.16 kg, 21.5 + 1.5 kg/m2 and 11.7 + 1.5 % body fat). The athletes of Group I performed the following tests: 1) an incremental treadmill test for the determination of AT. The velocity corresponding to AT (3.5 mM of blood lactate) was determined through linear interpolation; 2) constant tests - The MSSLAC was determined from 5 treadmill runs of up to 30 min duration and defined as the highest velocity at which blood lactate concentration did not increase by more than 1 mM between minutes 10 and 30 of the constant velocity runs and; 3) CV - The athletes performed two maximal running efforts of 1500 and 3000 m on a 400-m running track. The CV was calculated as the slope of the linear regression of distance run versus time. The athletes of Group II performed the following tests: 1) AWC - The athletes performed two maximal running efforts of 1500 and 3000 m on a 400-m running track. The AWC was calculated as the intercept of the linear regression of distance run versus time and; 2) Wingate test (WT) - The WT was performed against a resistance of 0.090 kp/kg. Maximal power (Pmax) and total work (TT) were the highest power and total work generated throughout the 30-s test, respectively. Analysis of variance revealed no significant differences between AT (13.9 +1.7 km/h) and MSSLAC... (Complete abstract, click electronic address below).
92

O efeito da duração de pausa no exercício intermitente: um estudo pelo modelo da potência crítica

Eleno, Thaís Guimarães [UNESP] 28 March 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:53Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-03-28Bitstream added on 2014-06-13T19:28:24Z : No. of bitstreams: 1 eleno_tg_me_rcla.pdf: 195961 bytes, checksum: 300673910af83cc4b49149d1b3f5f5a0 (MD5) / Conhecimentos sobre a participação dos metabolismos aeróbio e anaeróbio em exercício são importantes para compreender e prever os efeitos dos diferentes tipos de treinamentos. Muitos modelos têm sido propostos para a predição da participação dessas duas vias energéticas no exercício. Um deles, proposto em 1965, sugere a existência de uma intensidade de esforço, denominada potência crítica (PC), abaixo da qual o suprimento energético é dependente exclusivamente do metabolismo aeróbio. Até a intensidade da PC, o exercício pode ser realizado por longo tempo, sem exaustão. Acima dessa intensidade, as reservas anaeróbias de energia de dimensão finita denominada capacidade de trabalho anaeróbio (CTA), são requeridas e sua total depleção está associada com a exaustão. A aplicabilidade deste modelo vem sendo estudada e comprovada em exercícios contínuos, constituindo uma forma simples e não invasiva de se determinar as capacidades aeróbia e anaeróbia. O propósito deste estudo foi explorar o exercício intermitente através do modelo da potência crítica, principalmente quanto aos efeitos da duração da pausa na reposição da CTA. Indivíduos ativos foram submetidos a exercícios contínuos e intermitentes realizados em cicloergômetro, até a exaustão. Para os testes intermitentes, os regimes de esforço-pausa foram 15 s de exercício por 15 s, 30 s, 45 s e 60 s de pausa passiva. A PC e CTA foram determinadas a partir dos testes contínuos, através de regressão linear simples, segundo a equação P = CTA x 1/tlim + PC. A comparação entre as variáveis foi realizada através da análise de variância (ANOVA) para medidas repetidas, com nível de significância de 5% (p<0,05). Os principais resultados indicam que: da quantidade total de trabalho intermitente realizado, aproximadamente 58%, 85%, 88% e 90% correspondeu ao... / The knowledge of the contribution of aerobic and anaerobic metabolism during exercises plays a key role to anticipate the effects of different types of training. Many models have been proposed to predict the contribution of these two energetic pathways on the exercise work output. Among them, a model, proposed by Monod and Scherrer in 1965, suggests the existence of an exercise's intensity, named critical power (CP), below which the energetic supply is dependent, exclusively, on the aerobic metabolism. At the intensity corresponding to or below the critical power, the exercise can be done for a long time without exhaustion. Above this intensity, the finite anaerobic reserves of energy named anaerobic work capacity (AWC) are required and its total depletion is associated with exhaustion. The applicability of this model has been studied and confirmed in continuous exercises. It has been recognized as a simple and not invasive procedure to determine aerobic and anaerobic capacities. The purpose of this study was to explore the intermittent exercise through the critical power model, specifically the effects of the pause's duration on the replacement of the AWC. Active subjects were submitted to a continuous and intermittent ciclergometer exercises until exhaustion. For the intermittent tests, the exercise rest regimes were 15 s of exercise and 15 s, 30 s, 45 s and 60 s of passive recovery. The CP and AWC were determined by the results of continuous tests through a simple linear equation: P = AWC x 1/tlim + CP. The comparison among the variables was done by the analysis of variance (ANOVA) for repeated measures with a significance level of 5% (p<0,05). The main results indicated that: 1) from the total amount of intermittent work, approximately 58%, 85%, 88% and 90% was extra when compared to the continuous exercise for the same time of tests with 15 s, 30... (Complete abstract, click electronic address below)
93

Uso da Luffa cylindrica como meio suporte para crescimento bacteriano em filtro anaeróbio tratando esgotos domésticos

Fernandes, William Vieira 18 June 2012 (has links)
Made available in DSpace on 2015-05-14T12:09:09Z (GMT). No. of bitstreams: 1 parte1.pdf: 6125256 bytes, checksum: 9e961886d061a17367f2819c26c0b441 (MD5) Previous issue date: 2012-06-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The remoteness from urban centers, in general, is the most responsible for the not economically feasible implementation of a sewage disposal system. Simplified and high benefit/cost ratio systems may prove very useful as sanitary solution. In Brazil, anaerobic filters have been often used in septic tank sequence for the soluble fraction effluent's treatment, given technical and economic criteria. The use of Luffa cylindrica, or loofah sponge, as support media in anaerobic reactors, particularly in biofilters, still requires further investigation. The objective of this study was to investigate the feasibility of using this material in anaerobic filters as a low cost alternative for domestic sewage treatment. A system consisting of septic tank, flow divider box and anaerobic filters in parallel was built at the campus I UFPB. The filter F1 was filled with loofah sponge, the F2 with conduit chips and F3 with stone. Monitoring of flow and physical-chemical parameters of effluent was made during one year. Efficiencies were obtained in the order of 37.5%, 36.2% and 52.1% in BOD removal and 44.4%, 34.4% and 40.0% for COD removal for the F1, F2, and F3 filters respectively. There was no noticeable degradation in loofah sponge. It can be concluded that the systems performance was similar, indicating that Luffa cylindrica can be used as alternate support media in anaerobic filters. / O afastamento em relação aos centros urbanos, em geral, é o maior responsável por inviabilizar economicamente a implantação de uma rede coletora de esgoto nas comunidades periurbanas. Sistemas simplificados e de alta relação benefício/custo podem se mostrar bastante vantajosos como solução sanitária. No Brasil, o filtro anaeróbio tem sido frequentemente utilizado em sequência ao tanque séptico para tratamento da fração solúvel do efluente, atendendo aos critérios técnicos e econômicos. A aplicação da Luffa cylindrica, ou bucha vegetal, como meio suporte em reatores anaeróbios, em especial nos biofiltros, ainda necessita de maior investigação. O objetivo deste estudo é analisar a viabilidade técnica da utilização deste material em filtros anaeróbios como uma alternativa de baixo custo para o tratamento de efluentes domésticos. Foi construído um sistema composto por tanque séptico, caixa separadora de vazão e três filtros anaeróbios em paralelo, no Campus I da UFPB. O filtro F1 foi preenchido com bucha vegetal, o F2 com aparas de eletroduto e o F3 com brita. O monitoramento da vazão e de parâmetros físicoquímicos dos efluentes foi feito durante um ano. Foram obtidas eficiências na ordem de 37,5%, 36,2% e 52,1% na remoção de DBO5 e 44,4%, 34,4% e 40,0% na remoção de DQO para os filtros F1, F2 e F3, respectivamente. Não foi observada degradação apreciável na bucha vegetal. Pode-se concluir que o desempenho dos sistemas foi semelhante, demonstrando que a Luffa cylindrica pode ser utilizada como meio suporte alternativo em filtros anaeróbios.
94

Influência do uso de um dispositivo limitador de picos de vazão na performance de filtros anaeróbios pós tanques sépticos

Souza, Sofia Fernandes Lemos de 27 March 2014 (has links)
Made available in DSpace on 2015-05-14T12:09:31Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 3345939 bytes, checksum: 93e59e516029edded877772a287bd2f7 (MD5) Previous issue date: 2014-03-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / There are many technologies that seek efficient and cost compatible solutions to minimize the problem caused by sewage discharge. In cases of low density of occupation, or in peri-urban communities, where a sewerage system is difficult to implement, individual solutions can work satisfactory and economically. The septic tank has been the main alternative solution adopted to overcome the absence of sewerage and complementary treatment of their wastewater through anaerobic filters is a combined system that can achieve good removal efficiencies of biodegradable organic matter. However, these onsite systems are assumed to be implemented at generation effluent site, being subject to more pronounced peak flow than large systems, due to the proximity that they are installed from the sewage sources. The objective of this study was to evaluate the influence of flow attenuation on the performance of anaerobic filters treating tank septic effluents. It was conducted a comparative study between two identical filters filled with granite rocks, being only one of them, filter 1, preceded by a device that provides limitation of peak flows. These filters were installed in parallel and fed with septic tank effluent. Flow and physico-chemical parameters monitoring of the effluents was done over one year. During this period, the inclusion of a restriction peak flow chamber, preceding filter 1 provided an average reduction in peak flow of 48.6%, however, this did not significantly influence the removal efficiency of COD, BOD5, turbidity, settable solids, SS and VSS. Both filters have provided good results in the removal of organic matter and solids. The removal efficiencies of filter 1 were 32.8% for BOD5, 43.3% for COD, 49.8% for turbidity, 97.8% for settable solids, 56.2% for SS and 54.7% for SSV. For filter 2, the removal efficiencies were 31.5% for BOD5, 40.3% for COD, 45.1% for turbidity, 86.7% for settable solids, 52.3% for SS and 50.9% for VSS. Therefore, it can be concluded that, although the literature on the subject points to an interference of hydraulic loads on the reactor efficiency, in case of biomass adapted to another flow regime than those found in the present study, and biofilters fed by higher organic loads than those studied in this research, variations of spontaneous flow from the use of toilet facilities found in this present study, do not significantly influence the treatment efficiency of anaerobic filters fed with an average COD concentration of 192 mg/L. In addition, the inclusion of the restriction peak flow device, in fact increased the filter clogging occurrences, so that its adoption is not recommended. / São muitas as tecnologias que buscam soluções eficientes e de custo compatível para minimizar o problema gerado pelo lançamento de efluentes. Em casos de baixa densidade de ocupação, ou ainda de comunidades periurbanas, onde um sistema coletivo de esgotamento sanitário é de difícil implantação, as soluções individuais podem funcionar satisfatória e economicamente. O tanque séptico tem sido a principal solução alternativa adotada para suprir a inexistência de rede de esgotamento sanitário e o tratamento complementar de seu efluente através de filtros anaeróbios constitui um sistema combinado que pode atingir boas eficiências de remoção de matéria orgânica biodegradável. Entretanto, para estes sistemas individuais pressupõe-se implantação no local de geração do efluente, estando, portanto, sujeitos a picos de vazão mais acentuados que os sistemas coletivos, devido à proximidade com que são instalados das fontes geradoras de esgoto. O objetivo deste trabalho foi avaliar a influência da atenuação de picos de vazão na performance de filtros anaeróbios pós tanques sépticos. Efetuou-se um estudo comparativo entre dois filtros idênticos preenchidos com brita granítica Nº 4, sendo apenas um deles, o filtro 1, precedido por um dispositivo que proporciona limitação dos picos de vazão. Estes filtros foram instalados em paralelo e alimentados com efluente de tanque séptico. O monitoramento da vazão e de parâmetros físico-químicos dos efluentes foi feito durante um ano. Ao longo deste período, a inclusão da caixa limitadora de vazão antecedendo o filtro 1 proporcionou uma redução média na vazão de pico de 48,6%, entretanto, isto não influenciou significativamente a eficiência de remoção de DQO, DBO, turbidez, SSed, SS e SSV. Ambos os filtros propiciaram bons resultados na remoção de matéria orgânica e sólidos. As eficiências de remoção do F1 foram de 32,8% para DBO5, 43,3% para DQO, 49,8% para turbidez, 97,8% para SSed, 56,2% para SS e 54,7% para SSV. Para o filtro 2, as eficiências de remoção foram de 31,5% para DBO5, 40,3% para DQO, 45,1 % para turbidez, 86,7% para SSed, 52,3% para SS e 50,9% para SSV. Desta forma, pode-se concluir que apesar de a literatura relativa ao tema apontar para uma interferência da carga hidráulica sobre a eficiência do reator em casos de biomassas adaptadas a outros regimes de vazão que não os encontrados nesta presente pesquisa, e biofiltros alimentados por cargas orgânicas mais elevadas que as estudadas neste presente trabalho, variações de vazão espontâneas decorrentes do uso de instalações sanitárias não influenciam significativamente a eficiência do tratamento de filtros anaeróbios alimentados com concentração média de DQO de 192 mg/L. Paralelamente, a inclusão do dispositivo limitador de vazão, ainda aumentou a ocorrência de obstrução do meio suporte, de modo que pode-se concluir que o uso deste dispositivo não é necessário, podendo mesmo ser considerado indesejado.
95

Caracterização e estudo do comportamento térmico de lodo proveniente da indústria sucroalcooleira

Lourenço, Renato Vessecchi [UNESP] 24 November 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-11-24Bitstream added on 2014-06-13T20:38:18Z : No. of bitstreams: 1 lourenco_rv_me_sjrp.pdf: 618043 bytes, checksum: f0ce559908da201618d93514e1577b98 (MD5) / A indústria sucroalcooleira gera uma grande quantidade de lodo, o qual deve ser descartado de forma adequada. Na indústria sucroalcooleira o tratamento de efluentes pode ser realizado com o auxilio de um reator anaeróbio (Upflow Anaerobic Sludge Blanket- UASB). Este sistema produz aglomerados compactos de microrganismos anaeróbios em formato de grânulos, sendo estes os responsáveis pela decomposição da matéria orgânica em biogás. Assim, os microrganismos atuam como um poderoso biocatalisador capaz de converter altas taxas de matéria orgânica em metano. Devido a melhorias para o sistema UASB, uma nova série de reatores chamados Expanded Granular Sludge Bed (EGSB) foram desenvolvidos, entre as quais a tecnologia do reator de circulação interna (IC), que permite uma diluição eficaz de mistura e do efluente que entra no reator, ou seja, um melhor condicionamento da matéria orgânica a ser processada. Tendo em vista estes resíduos, aeróbio e anaeróbio, amostras destes lodos foram analisadas. Ambas as amostras foram caracterizadas, utilizando termogravimetria (TG), análise térmica diferencial (DTA), calorimetria exploratória diferencial (DSC), espectroscopia na região do infravermelho (FTIR), microscopia eletrônica de varredura (MEV), difratometria de raios X pelo método do pó (DRX), absorção atômica e outras técnicas analíticas de bancada (pH, DQO, temperatura, oxigênio dissolvido e resíduos sedimentáveis) . Os resultados a partir das curvas TG-DTA e DSC forneceram informações a respeito da desidratação e decomposição térmica destas amostras. Os espectros de FTIR sugerem a presença de grupos hidroxila devido à hidratação destes compostos; grupos carboxilatos e carboidratos proveniente de ácidos húmicos. Os difratogramas de raios X mostraram linhas de difração, sugerindo... / The sugarcane industry in the Brazil show a great amount of generated sludge which should be utilized adequately. In the sugarcane industry, the effluents can be treated within of an anaerobic reactor (Up flow Anaerobic Sludge Blanket - UASB). This system produces granules agglomerated compact of anaerobic microorganisms (granules) which are responsible for the decomposition of the organic matter in biogas. Like this, these act as a powerful biocatalyst. Due to improvements for the system UASB, a new series of reactors called Granular Expanded Sludge Bed (EGSB) were developed, with technology for internal circulation (IC), which allows an effective dilution of mixture and of the effluent that enters in the reactor. In other words, a better conditioning of the organic matter is obtained. Then, two sludge samples, aerobic and anaerobic, were obtained. Both samples were characterized, using thermogravimetry (TG), differential thermal analysis (DTA), differential scanning calorimetry (DSC), spectroscopic of absorption in infrared (FTIR), scanning microscopy electronic (SEM), X-ray diffraction patterns (DRX) and atomic absorption. The results obtained from TG-DTA and DSC curves, supplied information on the dehydration and thermal decomposition of these samples. The infrared absorption suggest that the are hydroxyl groups due to hydration of these compounds and carboxylic, and carbohydrates originating from humics. The X-ray diffraction patterns showed that these sludge’s have diffraction lines, suggesting that these compounds are crystalline due to presence of different metal oxides. The values of the activation energy (Ea) of these compounds were obtained from thermogravimetric curves ... (Complete abstract click electronic access below)
96

Caracterização e solubilização de lodo anaeróbio provenientes de reatores de baixo tempo de retenção celular / Characterization and solubilization of anaerobic sludge produced on short celular retention time reactor

Luna, Ysa Helena Diniz Morais de 11 April 2017 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2017-11-13T13:30:12Z No. of bitstreams: 1 PDF - Ysa Helena Diniz Morais de Luna.pdf: 14969298 bytes, checksum: 0533a4f938f12c09a36b687414201b77 (MD5) / Made available in DSpace on 2017-11-13T13:30:12Z (GMT). No. of bitstreams: 1 PDF - Ysa Helena Diniz Morais de Luna.pdf: 14969298 bytes, checksum: 0533a4f938f12c09a36b687414201b77 (MD5) Previous issue date: 2017-04-11 / Conselho Nacional de Desenvolvimento Científico e Tecnológico - CNPq / The biological sludge approprieate treatment must be developed in order to take advantages of the products generated during the process. However, the anaerobic sludge treatment is arduous due to the complexity of the substances present in sludge flakes, granules and biofilms, becoming indispensable a pre-treatment step in order to raise the solubilization of the materials. At this study, anaerobic sludges produced by anaerobic reactos with low cell retention time (CRT) (2, 4, 6, 8, 10 and 20 days) were characterized and the 2 and 8 day sludge were submitted to solubilization from pre- treatment commonly called alkaline hydrolysis, consisting of the use of NaOH to reach pH 12, and subjected to stirring for 48 hours at room temperature. The objective of this study was to characterize the anaerobic sludges and evaluate the increase of organic materials solubilization, and make comparisons. The results of the soluble organic materials at 2 and 8 days, showed an increase in the concentrations of 14 and 28 times COD, 20 and 40 times to DQOS, 21 and 63 times to carbohydrates and 31 to 60 times to proteins respectively The solubilization of the 8-day solubilized sludge showed higher solubilization than the 2-day sludge, showing that the use of anaerobic low-CRT reactor to generate sludge is interesting in order to produce a sludge that releases higher amounts of soluble materials after a hidrolisis process, be rapidly degradeted by the anaerobic digestion. / O tratamento adequado do lodo biológico deve ocorrer visando tirar proveito dos produtos gerados durante o processo. No entanto o tratamento anaeróbio do lodo biológico é dificultado pela complexidade das substâncias formadoras dos flocos, grânulos e biofilmes, fazendo-se indispensável uma etapa de pré-tratamento empregada de modo a elevar a solubilização dos materiais. No presente trabalho foram caracterizados 6 lodos anaeróbios provenientes de reatores com baixo tempo de retenção celular (2, 4, 6, 8, 10 e 20 dias) e destes, os lodos de 2 e 8 dias (fase acidogênica) foram submetidos à solubilização a partir do pré-tratamento químico comumente chamado de hidrólise alcalina, consistindo na utilização de NaOH para alcançar pH 12, sob agitação por 48 horas em 28°C. Objetivou-se caracterizar os lodos anaeróbios de baixo tempo de retenção celular (TRC) e avaliar o aumento da solubilização dos materiais orgânicos nos lodos de 2 e 8 dias. Os resultados dos materiais orgânicos solúveis nos lodos de 2 e 8 dias, apresentaram incremento nas concentrações de 14 e 28 vezes para COD, 20 e 40 vezes para DQOS, 21 e 63 vezes para carboidratos e 31 e 60 vezes para proteínas respectivamente. Evidencia-se em todos os parâmetros analisados uma maior solubilização do lodo solubilizado de 8 dias em relação ao lodo de 2 dias, mostrando assim ser interessante a utilização de reatores anaeróbios de baixo TRC para gerar um lodo que após hidrolisado, se solubilize seus materiais e seja degradado mais rapidamente.
97

Tratamento da vinhaça em reator anaeróbio de leito fluidificado / Anaerobic treatment of vinasse in fluidized bed reactor

Elisabeth dos Santos Gaspar Damiano 30 May 2005 (has links)
Este trabalho teve como objetivo avaliar o desempenho de um reator anaeróbio de leito fluidificado na degradação da vinhaça de cana-de-açúcar, sob condições mesofílicas. Ensaios batelada foram realizados a diferentes concentrações, visando avaliar a degradação do substrato pela biomassa anaeróbia e obtenção de parâmetros cinéticos. Vinhaça diluída a valores de DQO de 1984 mg/L, 2827 mg/L, 3800 mg/L, 6354 mg/L, 7395 mg/L, 10705 mg/L e 15872 mg/L foi utilizada nos experimentos, mostrando reduções de 67% em 192 horas, 75% em 358 horas, 81% em 408 horas, 80% em 480, 72% em 504 horas, 76% em 840 horas e de 71% em 1080, para essas concentrações, respectivamente. A reação ocorrida nos reatores foi analisada como sendo de ordem zero, com valor médio da constante de reação de 10,4 mg/L.h. Testes com partículas de poliamida, poliestireno e nylon foram realizados, objetivando a escolha da melhor partícula em termos de formação e desenvolvimento de biofilme para posterior uso no reator. As três partículas mostraram-se favoráveis à adesão e colonização de microrganismos. O reator anaeróbio de leito fluidificado foi inoculado com lodo proveniente de reator UASB, que tratava água residuária de abatedouro de aves. O volume do reator era de 770 cm3, operando com tempo de detenção hidráulica de 24 h. A partícula utilizada como material suporte foi poliestireno. O tempo de operação do reator foi de 122 dias, sendo aplicada vinhaça diluída a valores de DQO que variaram de 1009 mg/L a 15874 mg/L e COVa de 1,0 Kg/m3.d a 15,9 Kg/m3.d, apresentando resultado de remoção de DQO médio de 51% a 70% e COVrv de 0,5 Kg/m3.d a 7,9 Kg/m3.d. Observações microscópicas em MEV, mostraram boa adesão microbiana nas partículas de poliestireno, em todas as fases do reator. / This work had as objective evaluates the efficiency of a anaerobic fluidized bed reactor for vinasse degradation under mesophilic conditions. Batch tests seeking to evaluate the degradation of the substratum for the anaerobic biomass and obtaining kinetic parameters were accomplished to different concentrations. Diluted vinasse to values of 1984 mg/L, 2827 mg/L, 3800 mg/L, 6354 mg/L, 7395 mg/L, 10705 mg/L and 15872 mg/L of COD was used in the experiments showing reductions of 67% in 192 hours, 75% in 358 hours, 81% in 408 hours, 80% in 480, 72% in 504 hours, 76% in 840 hours and of 71% in 1080, for those concentrations, respectively. The reaction happened in the batch reactors it was analyzed as being of order zero, with medium value of 10,4 mg/L.h for the constant of reaction. Tests with polyamide particles, polystyrene and nylon were accomplished, aiming at the choice of the best particle in formation terms and biofilme development for subsequent use in the reactor. The three particles were shown favorable to the adhesion and colonization of microorganisms. The fluidized bed reactor was inoculated with sludge from reactor UASB treating effluent frompoultry slaughterhouse. The volume of the reactor was of 770 cm3, operating with hydraulic detention time of 24 h. Polystyrene particles were used as material support. The reactor was operated for 122 days, being applied diluted vinasse to values of COD 1009 mg/L ranging to 15874 mg/L and organic loading rate (OLR) of 1,0 Kg/m3.d to 15,9 Kg/m3.d, presenting efficiency COD removal of 51% - 70% and OLR removal of 0,5 Kg/m3.d - 7,9 Kg/m3.d. Microscopic observations in MEV showed good microbial adhesion in the particles of polystyrene, in all the phases of the reactor.
98

Utilização de biogás de estações de tratamento de esgoto para fins energéticos / Use of Biogas Wastewater Treatment Plants for Energy Purposes.

Thaisa Carolina Ferreira Silva 25 March 2015 (has links)
O aproveitamento energético do metano corresponde a uma das opções mais interessantes de utilização deste subproduto do tratamento de esgotos domésticos que é um gás de médio poder energético e também um gás indutor de efeito estufa (GEE). Esta dissertação visa estudar as perspectivas concretas de geração de eletricidade a partir da recuperação e do uso do biogás oriundo do processo de tratamento anaeróbio de esgotos domésticos mediante atualização dos marcos regulatórios brasileiros e levantamento experimental das taxas de produção de biogás em Estações de Tratamento de Esgotos (ETEs). Nesse contexto, foram quantificadas, em tempo real, as taxas de produção de biogás e de metano de uma ETE de grande porte (3556,8 m3 tratados/hora), contendo 16 reatores UASB, alimentados com esgotos domésticos. Os resultados apontaram uma grande variação na carga orgânica recebida (37.948 ± 11.993) kg/dia e na vazão de biogás da ETE (84,30 ± 26,64) Nm3/h, que podem ser influenciadas negativamente por eventos de chuva. De modo geral, as quantidades médias de vazão de biogás estimadas em estudos foram maiores que aquelas registradas a partir de medições, dependendo do método utilizado tal quantidade pode ser até 10 vezes maior que aquela verificada a partir de medições de campo. A potência elétrica máxima calculada em 233 kW se mostrou próxima da autossuficiência da ETE e as novas diretrizes regulatórias podem permitir a compensação de energia de outras ETEs do sistema. As emissões de metano podem reduzir significativamente, cerca de 7.476,7 t CO2eq, quando do aproveitamento energético e possibilitam a venda de Certificados de Emissões Evitadas de Carbono. Conclui-se que, com o planejamento adequado, é possível haver interação entre saneamento ambiental e geração de energia com benefícios para ambos os setores. / The energy use of biogas corresponds to one of the most interesting use options of this by-product of wastewater treatment which is a mean-energy power and also a greenhouse gas. In this sense, this work aims to study the concrete prospects for electricity generation from the recovery and use of biogas derived from process of anaerobic treatment of wastewater by updating the Brazilian regulatory frameworks and experimental survey of biogas production rates in Wastewater Treatment Plants (WTP). In this context, were quantified in real time, biogas and methane production rates of a large WTP (3556.8 m3 treated / hour) containing 16 UASB reactors fed with domestic wastewater. The results showed a wide variation in the incoming organic load (37.948 ± 11.993) kg/dia and flow of biogas and methane from WTP (84,30 ± 26,64) Nm3/h, which can be negatively influenced by rainfall events. In general, the average quantities of biogas flow studies were estimated at greater than those recorded from measurements depending on the method used such amount can be up to 10 times higher than that found from field measurements. The maximum electric power estimated at 233 kW proved close to the WTP self-sufficiency and the new measures taken by the regulatory guidelines could allow power compensation in other WTPs system. Methane emissions can significantly reduce, about 7.476,7 t CO2eq, when the biogas was used for energy generation and may allow the sale of Avoided Carbon Emissions Certificates. So it is concluded that, with proper planning, it is possible to have interaction between environmental sanitation and power generation with benefits for both sectors.
99

Remoção da microalga Chlorella sorokiniana, cultivadas em fotobiorreatores, alimentados com efluente de reator anaeróbio tratando esgoto sintético, com emprego da técnica de ozonização seguida de flotação por ar dissolvido (FAD) / Removal of the microalgae Chlorella sorokiniana, grown in photobioreactor fed with anaerobic reactor effluent treating synthetic sewage, using the technique of ozonation followed by dissolved air flotation (DAF)

Thadeu Salin Sahão 14 June 2017 (has links)
O tratamento anaeróbio de esgoto doméstico em combinação com a produção de biomassa de algas é considerado uma excelente alternativa para a remoção de nutrientes. O processo de separação sólido-líquido de microalgas continua sendo um grande desafio técnico e econômico. A ozonização seguida de flotação por dissolvido é uma alternativa interessante visando a separação de microalgas e, consequentemente, a remoção de nutrientes. Os objetivos deste trabalho foram: avaliar a remoção de nitrogênio e fósforo de um efluente de reator anaeróbio através do crescimento da microalga Chlorella sorokiniana em fotobiorreator tipo flat panel e investigar o uso da ozonização associada à flotação por ar dissolvido para o processo de separação sólido-líquido da microalga Chlorella sorokiniana. O efluente anaeróbio foi obtido a partir de um reator anaeróbio com leito de fibras flexíveis que trata esgoto doméstico sintético. As microalgas foram cultivadas em fotobiorreator flat panel com tempo de cultivo de cinco dias, sob condições controladas: intensidade de luz (196 &#956;mol m-2 s-1), fluxo de ar (0,2 vvm), temperatura (29 ± 1 °C) e fotoperíodo (12 horas com iluminação artificial e 12 horas no escuro). No final do período de cultivo, foram realizados ensaios para adequação da FAD e da ozonização, através da avaliação de parâmetros, tais como: dosagem de ozônio, dosagem de polímero, pH, tempos e gradientes de mistura rápida e floculação, velocidade de flotação e quantidade de ar necessária para flotação por ar dissolvido. O reator anaeróbio apresentou altas eficiências de remoção de demanda química de oxigênio e demanda bioquímica de oxigênio: 63 ± 6% e 53 ± 8%, respectivamente. Ao final do período de cultivo das microalgas no fotobiorreator, as remoções de nitrogênio total dissolvido e fósforo total dissolvido foram de 52,1% e 31,8%, respectivamente. Analisando os resultados referentes à etapa de separação sólido-líquido, verificou-se que o pH não influenciou significativamente na eficiência do tratamento; altas velocidades de flotação (24 cm.min-1 e 36 cm.min-1) podem ser empregadas; a etapa de floculação não contribuiu para melhora do tratamento; e a ozonização não contribuiu significativamente para a melhora da eficiência do processo de separação sólido-líquido. / Anaerobic treatment of wastewater in combination with the production of algae biomass is an excellent alternative for nutrient removal. The process of solid-liquid separation of microalgae remains a major technical and economic challenge. Ozonization followed by flotation by dissolved air is an interesting alternative for the separation of microalgae and removal of nutrients. The objectives of this work were: to evaluate the nitrogen and phosphorus removal of an anaerobic effluent through the growth of Chlorella sorokiniana microalgae in a flat panel photobioreactor and to investigate the use of ozonation associated with dissolved air flotation (DAF) for the solid-liquid separation of the microalga Chlorella sorokiniana. The anaerobic effluent was obtained from a fixed-bed anaerobic reactor with flexible fibers. The microalgae were grown in a flat panel photobioreactor for five days, under controlled conditions: light intensity (196 mol &#956;m -2 s-1), Airflow (0.2 vvm), temperature (29 ± 1°C) and photoperiod (12 hours). At the end of the cultivation period, tests were carried out to adjust FAD and ozonization through the evaluation of parameters such as: ozone dosage, polymer dosage, pH, fast mixing and flocculation times and gradients, flotation velocity. The anaerobic reactor presented high efficiency of removal of COD and BOD, 63 ± 6% and 53 ± 8%, respectively. At the end of the microalgae culture period in the photobioreactor, the removal of total nitrogen, total phosphorus and total dissolved carbon of the effluent from the anaerobic reactor were 52.1%, 31.8% and 66.2%, respectively. Analyzing the results concerning the separation step, it was verified that the pH did not influence the removal efficiencies, high flotation rates can be employed in the separation process, the flocculation step in the treatment was not necessary and ozonation didnt contributed to an improvement the solid-liquid separation process.
100

Remoção de corantes AZO em sistema de reator anaeróbio/aeróbio e em reator UASB micro-aerado

AMARAL, Fernanda Magalhães 21 August 2015 (has links)
Submitted by Isaac Francisco de Souza Dias (isaac.souzadias@ufpe.br) on 2016-03-30T18:37:20Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Tese-Fernanda Magalhães Amaral.pdf: 2354474 bytes, checksum: 3fdb4eedcc11785015fb228184b3168e (MD5) / Made available in DSpace on 2016-03-30T18:37:20Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Tese-Fernanda Magalhães Amaral.pdf: 2354474 bytes, checksum: 3fdb4eedcc11785015fb228184b3168e (MD5) Previous issue date: 2015-08-21 / CNPQ / Este trabalho foi conduzido em dois experimentos: no primeiro se operou um sistema de tratamento em escala piloto formado por um reator anaeróbio tipo UASB seguido por biofiltro aerado submerso (BAS); no segundo experimento, dois reatores tipo UASB em escala de laboratório foram operados, sendo R1 um reator UASB convencional e R2 um reator UASB com micro-aeração. Os reatores do primeiro experimento foram instalados em uma lavanderia de jeans, alimentados com efluente têxtil real e operados por 373 dias efetivos em duas fases experimentais: F-I e F-II, com tempos de detenção hidráulica para os reatores UASB-BAS iguais a 16h-12h, e 4d-3d, respectivamente. O melhor desempenho do sistema (UASB+BAS) foi obtido em F-II, com eficiência média de remoção de DQO e cor iguais 70% e 67%, respectivamente. Aminas aromáticas, subprodutos geralmente tóxicos da degradação dos azo corantes, foram detectadas em condições anaeróbias, tendo sido removidas na etapa aeróbia em ambas as fases. No segundo experimento os reatores R1 e R2 foram alimentados com efluente sintético e operados por 290 dias efetivos em três fases operacionais: F-I, alimentação com efluente com salinidade de 1,9‰; F-II, aumento do nível de salinidade de 1,9 para 3,2‰ e F-III, com salinidade mantida em 3,2‰, na presença de sulfato (400 mg SO42-/L), adicionado ao efluente sintético. Os resultados do segundo experimento indicaram comportamento semelhante com relação à remoção de cor e DQO em ambos os reatores em todas as fases. A adição de sulfato não alterou a remoção de cor. Portanto o sulfato não concorreu com o corante azo pelos aceptores de elétrons. Em R2 observou-se sensibilidade da comunidade microbiana ao aumento da salinidade de 1,9‰ para 3,2‰. As aminas aromáticas acumularam em R1, e foram removidas em R2. Este resultado indicou a possibilidade de tratamento de efluente têxtil sintético em um único reator. Análise de biologia molecular, por DGGE, das amostras dos reatores R1 e R2 indicou que a diversidade microbiana em R1 era diferente da encontrada em R2 e que a micro-aeração realizada não inibiu o desenvolvimento de micro-organismos metanogênicos. / The study was conducted in two experiments: the first operated a treatment system on a pilot scale consists of a UASB type anaerobic reactor followed by submerged aerated biofilter (SAB); In the second experiment, two UASB type reactors at laboratory scale were operated, with a conventional UASB reactor R1 and R2 reactor with micro-aeration. The first experiment reactors were installed in a jeans laundry, fed real textile effluent and operated for 373 days effective in two experimental phases: P-I and P-II, with hydraulic retention times for UASB equal to 16h- 12h and the SAB 4d-3d, respectively. The best system performance (UASB and SAB) was obtained in IP-I with an average COD removal efficiency and color equal to 70% and 67%, respectively. Aromatic amines, generally toxic by products of degradation of azo dyes were detected in anaerobic conditions has been removed in the aerobic step in both phases. In the second experiment, the reactors R1 and R2 were fed synthetic effluent effective and operated by 290 days in three operational stages: P-I, feeding effluent salinity from 1.9 ‰; P-II, increased salinity from 1.9 ‰ to 3.2 and P-III with saline maintained at 3.2 ‰ sulfate was added (400 mg SO42-/ L) to the synthetic effluent. The results of the second experiment showed similar behavior with respect to the removal of color and COD in both reactors in all stages. The adding sulphate didn’t change color removal. Therefore sulphate not competed with the azo dye by electron acceptors, in R2 observed sensitivity of the microbial community to increased salinity 1.9‰ to 3.2‰. Aromatic amines accumulated in R1 and R2 were removed at. This result indicated the possibility of treatment of synthetic textile effluent in a single reactor. Analysis of molecular biology, for DGGE of samples from reactors R1 and R2 indicated that microbial diversity in R1 was different from that found in R2 and the micro-aeration performed not inhibited growth of methanogenic microorganisms.

Page generated in 0.0483 seconds