• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1324
  • 195
  • 124
  • 74
  • 16
  • 16
  • 15
  • 15
  • 13
  • 8
  • 3
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 1747
  • 1212
  • 470
  • 300
  • 259
  • 249
  • 211
  • 211
  • 186
  • 183
  • 173
  • 152
  • 129
  • 116
  • 115
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Construção, caracterização e aplicações de eletrodos modificados por poli-l-lisina e nanoeletrodos na análise de alguns compostos farmacêuticos /

Pereira, Francisco Claudece January 2003 (has links)
Orientador: Maria Valnice Boldrin Zanoni / Banca: Vicente Assis Benedetti / Banca: Mauro Bertotti / Banca: Lauro Tatsuo Kubota / Banca: Sergio Antonio Spinola Machado / Resumo: A formação de filmes do poliaminoácido poli-l-lisina, (PLL), foi investigada sobre eletrodo de carbono de duas formas distintas: pela sua imobilização direta na superfície do eletrodo obtido pela deposição de 10 μL de uma alíquota seguido de secagem a 80oC em estufa e com a utilização do agente de ligação cruzada Glutaraldeído. Filmes de PLL sobre eletrodo de carbono pirolítico apresentaram-se suficientemente estáveis para pré-concentração do fármaco antiasmático cromoglicato disódico com máxima interação em valor de pH 4,0. Utilizando-se filmes do poliaminoácido obtido com soluções a 1,0% m/v de PLL foi possível estabelecer uma curva analítica para monitoramento do composto em valores de concentração entre 2,18x10-7 mol L-1 a 3,29x10-6 mol L-1 e limite de detecção de 2,1x10-8 mol L-1. A aplicação do procedimento proposto foi realizada para a determinação da droga em urina humana segundo o método de adições-padrão apresentando índices de recuperação de 99,8%, compatível com valores obtidos em procedimentos espectrofotométricos. O nitroprussiato de sódio pode ser monitorado voltametricamente com filmes de PLL imobilizados na superfície do eletrodo de carbono vítreo com auxílio do agente de ligação cruzada Glutaraldeído. O fármaco é pré-concentrado na superfície modificada e exibe maior amplificação de corrente em valor de pH 4,0. Utilizando as melhores condições analíticas, uma curva de calibração foi obtida no intervalo de concentração de 1,21x10-6 a 2,06x10-5 mol L-1 e limite de determinação igual a 4,62x10-7 mol L-1. A aplicação da metodologia foi conduzida para a determinação de NIPRIDE® em plasma e urina humana apresentando índices de recuperação de 95,0% e 96,2%, concordante com resultados obtidos por ensaios espectrofotométricos. A investigação sobre o comportamento voltamétrico do iodeto de potássio com...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The formation of polyelectrolyte film, poly-l-lysina (PLL), was investigated using carbon electrode in two distinct manners: by direct surface immobilization of the electrode obtained by depositing 10 μL of aliquot followed by heating at 80ºC; and with the use of a cross linking agent, glutaraldehyde. PLL films subjected to pirolitic carbon electrode presented themselves as sufficiently stable for the pre-concentrated anti-asthmatic pharmaceutical disodium cromoglicate with a maximum interaction value of pH 4.0. Using polyelectrolyte films, obtained with solutions of PLL 1.00 %m/v it was possible to establish an analytic curve for monitoring the composition in varying levels of concentration, between 2.18x10-7 mol L-1 - 3.29x10-6 mol L-1 and a detection limit of 2.1x10-8 mol L- 1. The proposed application procedure was realized for drug determination in human urine followed by the method of standard additions presenting indexes of recovery, 99.8%, compatible with values obtained by spectrophotometric procedures. The sodium nitroprusside can be monitored voltammetrically with PLL films, immobilized on the surface of a glassy carbon electrode with the assistance of the bonding agent glutaraldheyde. The pharmaceutical is pre-concentrated on the modified surface and exhibited larger current amplification at pH 4.0. Using the best analytic conditions, the calibration curve was obtained at the concentration interval of 1,21x10-6 to 2,06x10-5 mol L-1, and a determination limit equal to 4,62x10-7 mol L-1. The application of this methodology was used to determine NIPRIDE® in plasma and human urine presenting levels of recovery of 95.0% and 96.2%, which agree with the results achieved by spectrophotometric tests...(Complete abstract, click electronic access below) / Doutor
242

Estudo eletroquímico e termoanalítico dos sistemas Ir/Hg e Pt - (30%) Ir/Hg /

Milaré, Edilson January 2004 (has links)
Resumo: Eletrodos laminares de Ir ou Pt-Ir(30%) foram empregados como substratos para deposição eletroquímica de Hg, a partir de soluções contendo íons Hg(I), e remoção deste Hg por meio de voltametria cíclica (VC) ou térmica (termogravimetria / termogravimetria derivada - TG/DTG e calorimetria exploratória diferencial - DSC). A superfície dos eletrodos foi caracterizada empregando-se as técnicas complementares de análise: microscopia eletrônica de varredura (imagens SEM, microanálise por EDX e mapas de distribuição de elementos), microscopia eletrônica de transmissão (imagens TEM, microanálise por EDX e difração de elétrons), difratometria de raios X (XRD) e espectroscopia fotoeletrônica de raios X (XPS). Os voltamogramas cíclicos obtidos para o sistema Ir/Hg mostram até 3 picos na região de varredura de potenciais decrescentes, que foram atribuídos a: deposição de Hg em regime de subpotencial (UPD); deposição de Hg volumétrico, e redução de óxidos. A curva de I-E para a varredura de potenciais crescentes mostra até 6 picos, dependendo do tratamento empregado, que foram atribuídos a: oxidação de Hg volumétrico a Hg(I); oxidação de Hg(I) a Hg(II); oxidação de Hg presente no filme sobre a superfície do substrato a Hg(II); oxidação de Hg presente na sub-superfície do eletrodo a Hg(II); formação de óxidos. Os voltamogramas cíclicos obtidos para o sistema Pt-Ir(30%)/Hg mostram até 4 picos na varredura de potenciais decrescentes, que foram atribuídos a: deposição de Hg em regime de subpotencial (UPD) e redução de óxidos, concomitantemente; deposição eletroquímica de Hg volumétrico, e formação de produtos de interação Hg-substrato. Na varredura de potenciais crescentes a curva I-E mostra até 6 picos, dependendo do tratamento empregado, atribuídos a: oxidação de Hg volumétrico a Hg(I); oxidação...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Laminar electrodes of Ir or Pt-(30%)Ir were used as substrates for electrodeposition of Hg from Hg(I)-containing solutions, and Hg removal, using cyclic voltammetry (CV) or thermal analysis (thermogravimetry / derivated thermogravimetry - TG/DTG and differential scanning calorimetry- DSC). The electrode surface was characterized using complementary techniques for surface analysis: scanning electron microscopy (SEM images, EDX microanalysis and mapping of elements), transmission electron microscopy (TEM images, EDX microanalysis and electron diffraction), X ray diffratometry (XRD) and X ray photoelectron spectroscopy (XPS). The cyclic voltammograms of the Ir/Hg system shows at least 3 peaks in the cathodic potential scan, which were attributed to: underpotential deposition of Hg (UPD); bulk Hg deposition, and; reduction of oxides. In the anodic potential scan up to 6 peaks can be observed (depending on the treatment used), which were attributed to: bulk Hg oxidation to Hg(I); oxidation of Hg(I) to Hg(II); oxidation of Hg film formed on the substrate surface to Hg(II); oxidation of Hg from the sub-surface to Hg(II); the formation of oxides. The cyclic voltammograms obtained for the Pt-(30%)Ir/Hg system show up to 4 peaks in the cathodic potential scan, which were attributed to: underpotential deposition of Hg (UPD) and the reduction of oxides, concomitantly; bulk Hg deposition, and; the formation of products of Hg-substrate interaction. In the anodic potential scan up to 6 peaks could be recorded (depending on the electrode treatment), which were attributed to: bulk Hg oxidation to Hg(I); oxidation of Hg film from the substrate surface to Hg(II); the formation of oxides and decomposition of intermetallic compounds formed by Hg-substrate interactions, and Hg removal from substrate and decomposition of Pt/Hg intermetallic compounds. The Hg was also deposited at an open-circuit potential...(Complete abstract click electronic access below) / Orientador: Assis Vicente Benedetti / Coorientador: Fernando Luis Fertonani / Banca: Luis Alberto Avaca / Banca: Nelson Ramos Stradiotto / Banca: Jivaldo do Rosário Matos / Banca: Zeki Naal / Doutor
243

Preparação, caracterização e aplicação de carbono polimérico vítreo em sensores eletroquímicos /

Silva, Luiz Fernando da. January 2007 (has links)
Resumo: A rota sintética do carbono vítreo é bem conhecida, da mesma forma, são notórias suas propriedades estruturais e condutoras, como também as aplicações deste material, principalmente em eletroquímica. Todavia, existe uma classe de materiais com base em carbono, que possui propriedades similares as do carbono vítreo, mas ainda são pouco destacados na pesquisa acadêmica. Estes materiais são obtidos a partir da pirólise de resinas poliméricas como as fenólicas, furfurílica e poliacrilato, e que apresentam condutividade elétrica e térmica e boa resistência mecânica. Entretanto, por serem tratados a temperaturas (até 1200ºC), inferiores a de produção do carbono vítreo podem possuir "falhas" na sua estrutura, que podem causar variações previsíveis ou não, em seu comportamento eletroquímico, como menor condutividade ou maior afinidade com determinadas moléculas. Pertencendo a esta classe se encontra o carbono polimérico vítreo (CPV) material similar ao carbono vítreo comercial, mas que em sua estrutura ainda conserva características do precursor, como grupos funcionais hidroxílicos e carboxílicos. Dessa forma, este trabalho apresenta a obtenção do CPV a partir de uma resina fenólica comercial, estuda suas propriedades estruturais e eletroquímicas, sendo que para isso foi desenvolvido o processo de síntese, foram efetuados experimentos de caracterização com técnicas de análise termogravimétrica com análise térmica diferencial, difração de raios-X, infravermelho com transformada de Fourrier, voltametria cíclica e espectroscopia de impedância eletroquímica. O comportamento eletroquímico, utilizando o sistema ferricianeto/ferrocianeto, é similar ao obtido com eletrodo comercial de carbono vítreo e platina. O material possui estabilidade térmica em atmosfera oxidante até o limite de temperatura de 600ºC. Já em atmosfera inerte apresenta...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The synthetic route to obtain glassy carbon is well known, as well as its structural and conductive properties and its use in electrochemistry. However, there is a class of based carbon material which possesses similar properties to glassy carbon, but with a lack of interest in academic community. These materials are produced from pyrolysis of either phenolic or furfurylic resin, named glassy polymeric carbon, and they present thermal stability, robustness, mechanical strength, electrical conductivity and large potential range. Notwithstanding these characteristics, as these carbon based materials is prepared at low temperature (approximately 1200 oC) some kilning faults can be arisen leading to predictable changes in electrochemical behavior. In addition, after the preparation, glassy polymeric carbon maintains functional groups such as carboxyl and hydroxyl. In this context, the present work describes the synthesis of glassy carbon from commercial phenolic resin, structural characterization, and the application as working electrode and the potential use as support to chemically modified electrodes. The electrochemical behavior by using hexacyanoferrate system is quite similar to glassy carbon and platinum commercial electrodes. Moreover, the obtained carbon material is thermally stable under air atmosphere up to 600 oC and decomposes slightly up to 1050 oC under inert condition. Afterwards, the glassy polymeric electrode was found to be a useful tool for electroanalytical purposes. In particularly, it was developed a electrochemical sensor to caffeic acid in complex matrix such as red wine by applying voltammetric techniques (cyclic voltammetry, square wave and differential pulse voltammetry). Furthermore, it was investigated the effect of metallic ion doping and surfactant molecules during the synthesis on the properties of the glassy polymeric carbon. In fact, these set of experiments...(Complete abstract click electronic access below) / Orientador: Nelson Ramos Stradiotto / Coorientador: Herenilton Paulino Oliveira / Banca: Paulo Olivi / Banca: Luiz Henrique Mazo / Banca: Grégore Jean-François Demets / Banca: Lauro Tatsuo Kubota / Doutor
244

Extração e identificação de material lignocelulósico presente durante o processo de compostagem /

Bernabé, Giseli Aparecida. January 2008 (has links)
Orientador: Clóvis Augusto Ribeiro / Banca: Eder Tadeu Gomes Cavalheiro / Banca: Eny Maria Vieira / Resumo: Neste trabalho foram estudados a extração e identificação de material lignocelulósico presente durante o processo de compostagem de Resíduos Sólidos Domiciliares (R.S.D). Amostras foram recolhidas em diferentes estágios de compostagem: cru (ou 0 dias), 15; 30; 60; 90 e 120 dias e realizadas suas respectivas extrações de lignina e celulose. Anteriormente à extração de lignina do composto, foi necessária a realização de duas extrações: aquosa e lipídica, a fim de que o máximo de substâncias solúveis e ácidos graxos fossem removidos previamente à extração de lignina, sendo que nesta, utilizou-se uma mistura de HCl/dioxano (9:1) para tal fim. Enquanto que para a extração de celulose do composto foi utilizada solução de NaOH ( hidróxido de sódio a 4%). Curvas de Calorimetria Exploratória Diferencial (DSC) foram obtidas paras as diversas amostras de composto; para celulose e lignina extraídas do mesmo, em diferentes períodos de compostagem. A caracterização de lignina do composto foi feita, também por diferentes técnicas: Termogravimetria (TG), Infravermelho (IV) e Ultravioleta (UV). Os resultados obtidos pelas curvas DSC do composto, lignina e celulose mostraram que os dois últimos estavam presentes do início ao final da compostagem. No entanto, seus perfis não eram mais de lignina e celulose, mas sim, de material tipo-lignina e tipo-celulose, já que estes sofreram decomposição, combinação ou transformação em suas estruturas durante todo o processo; o que pode ser evidenciado, principalmente para material tipo-lignina, com as análises de Infravermelho e Ultravioleta. / Abstract: The extraction and identification of lignincellulosic material during the composting process of domiciliar solid residues (RSD) were studied in this work. Samples were collected in different composting steps: raw (or 0 days), 15, 30, 60, 90, and 120 days, lignins and cellulose extractions were performed. Previously to the compost's lignin extraction, it was necessary aqueous and lipidic extractions so that the maximum of soluble substances and fatty acids were removed before lignin extraction. In this process was used HCl: dioxane (9:1) mixture, while to the compost's cellulose extraction was used (4% NaOH solution). DSC curves were obtained to several compost samples; to cellulose and lignin extracted from the same compost in different composting periods. The lignin extracted from the compost was also analysed through several techniques: Thermogravimetry (TG), Infra Red (IR) and Ultraviolet (UV) spectrophotometry. The obtained results through DSC curves of compost, lignin and cellulose showed that the last two ones were presented from the beginning to the end of composting process. However their structures weren't of lignin and cellulose anymore, but a material like-lignin and likecellulose, because they undergone decomposition, combination and transformation in their structures during all process, which could be evidencied, mainly to like-lignin material, with the IR and UV analyses. / Mestre
245

Desenvolvimento de métodos para determinação de sulfonamidas, dipirona e citrato de sildenafil em matrizes diversas /

Weinert, Patrícia Los. January 2008 (has links)
Resumo: Este trabalho propõe métodos analíticos simples, rápidos e de baixo custo para determinação de dipirona, citrato de sildenafil (Viagra®) e sulfonamidas em formulações farmacêuticas e também o screening de sulfonamidas em amostras complexas, tais como urina, água superficial e leite bovino. A determinação de Viagra® foi efetuada utilizando a técnica de espectrofotometria com medidas na região visível do espectro. O método envolveu a reação entre citrato de sildenafil e tetraclorobenzoquinona (p-cloranil), acelerada pela adição de H2O2 produzindo um complexo colorido estável (λ = 535 nm). Para a determinação de dipirona foram empregados um método reflectométrico e o procedimento de análise por injeção em fluxo com detecção espectrofotométrica. Ambos baseiam-se na reação entre dipirona e p-dimetilaminocinamaldeído em meio ácido, com formação de produto colorido (λ = 510 nm), sobre a superfície de um papel de filtro no método reflectométrico e em solução no procedimento em fluxo. Neste último método, o uso de meio micelar conferiu significativo aumento na sensibilidade analítica, possibilitando o desenvolvimento de um método bastante sensível para a determinação de dipirona. O screening de sulfonamidas em urina, água superficial e leite bovino empregando procedimento de análise por injeção em fluxo em meio micelar com detecção espectrofotométrica (λ = 555 nm) está baseado na reação entre sulfonamidas e p-dimetilaminocinamaldeído em meio ácido. Para as duas primeiras amostras foi possível o emprego da extração em fase sólida acoplada diretamente ao sistema em fluxo. O uso de meio micelar conferiu ao método grande sensibilidade analítica possibilitando sua aplicação no screening dos analitos de acordo com o valor de limite máximo de resíduo permitido (100 ppb)...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work proposes simple, fast and of low cost analytic methods for dipyrone, sildenafil citrate (Viagra®) and sulfonamides in pharmaceutical formulations and also the sulfonamides screening in complex samples, such as urine, water and bovine milk. The determination of Viagra® was carried out using the spectrophotometry technique with detection on the visible spectrum. The method involved the reaction between sildenafil citrate and tetrachlorobenzoquinone (p-chloranil), accelerated by the addition of H2O2 producing a stable colored complex (λ = 535 nm). For the dipyrone determination a reflectometric method and the flow injection analysis with spectrophotometric detection procedure were used. The both methods are based on the reaction between dipyrone and p-dimethylaminocinnamaldehyde (p-DAC) in acid medium, with formation of a colored product (λ = 510 nm), on the surface of a filter paper to the reflectometric method and in solution for the procedure in flow. In this last method, the use of micelar medium granted a significant increase of the analytic sensibility, allowed the development of a quite sensitive method for dipyrone determination. The sulfonamide screening in urine, water and bovine milk using the flow injection analysis procedure in micelar medium with spectrophtometric detection (λ = 555 nm) is based on the reaction between sulfonamides and p-DAC in acid medium. For the two first samples the solid phase extraction coupled directly at flow system was possible. The use of micelar medium granted to the method a great analytical sensibility allowed its application for the screening of the analytes in agreement with the residue maximum limit value acceptable (100 ppb). The micelar medium also allowed the elution of the analytes retained on the C-18 minicolumns without the need of the use the organic solvents. The experimental design...(Complete abstyract click electronic access below) / Orientador: Helena Redigolo Pezza / Coorientador: Leonardo Pezza / Banca: Massao Ionashiro / Banca: Boaventura Freire dos Reis / Banca: Ronaldo Censi Faria / Banca: Horácio Dorigan Moya / Doutor
246

Aplicações da técnica de fotoeletrocatálise na oxidação de corantes ácidos, corantes dispersos, surfatantes e na redução de 'CR'((VI) e bromato em efluentes usando eletrodos nanoporosos de 'TI'/'TI''O IND.2' /

Paschoal, Fabiana Maria Monteiro. January 2008 (has links)
Orientador: Maria Valnice Boldrin Zanoni / Banca: Maria del Pilar Taboada Sotomayor / Banca: Christiane de Arruda Rodrigues / Banca: Marcos Roberto de Vasconcelos Lanza / Banca: Luiz Henrique Dall'Antonia / Resumo: O presente trabalho ilustra diversas aplicações da técnica de fotoeletrocatálise, tais como: degradação de corantes têxteis, corantes de curtumes, surfatantes, redução de Cr(VI) a Cr(III) e redução de bromato a brometo, usando eletrodos de filmes finos de Ti/TiO2 e luz ultravioleta. A oxidação fotoeletrocatalítica de soluções simuladas de efluentes de curtumes contendo dicromato de potássio, o corante ácido vermelho e o surfatante Tamol® foi investigada em Na2SO4 0,1 mol L-1 usando anodos de filme fino de TiO2 sob potencial de + 1,0 V e irradiação UV-Vis. Foi obtido 100% de remoção do corante ácido vermelho 151 e 98,5% de redução de Cr(VI) a Cr(III) e 94,6% de remoção de carbono orgânico total (COT), após 60 min de fotoeletrocatálise em pH = 2,0. A técnica de fotoeletrocatálise foi ainda aplicada na degradação de dois efluente industriais contendo corantes dispersos em Na2SO4 0,1 mol L-1. Os resultados obtidos mostraram descoloração de 95%, 97%, e 100% de remoção dos corantes dispersos: laranja, rubi e vermelho dispersil, sendo que a porcentagem de mineralização foi de 62,7%; 43,3% e 61,3%, respectivamente. Remoção de 80-89% da coloração dos efluentes foram conseguidas após 360 min de fotoeletrocatálise, concomitante à redução de 49,8% e 46,8% de COT e 50% de redução da demanda química de oxigênio (DQO). O método mostrou-se ainda adequado para a redução de 0,25 mg L-1 de bromato a brometo com máxima performance sob potencial de -0,2 V e luz UV, usando o Ti/TiO2 como fotocátodo. O método promoveu 65% de redução de bromato após 75 min de tratamento. / Abstract: In the present work has been studied the application of photoelectrocatalytic process to degradation of acid dyes, disperse dyes, surfactant, Cr (VI)/Cr (III) reduction and BrO3 -/Brreduction, using Ti/TiO2 electrodes and UV- Vis irradiation. The photoeletrocatalytic oxidation of simulated leather industry wastewater containing Cr(VI), acid red 151 dye, Tamol® surfactant was investigated in Na2SO4 0,1 mol L-1 solution using Ti/TiO2, potencial of + 1.0V and UV irradiation. 100% of color removal, 98.5% of Cr(VI)/Cr (III) reduction and 94.6% of TOC removal were obtained after 60 min of treatment at pH = 2.0. The photoelectrocatalytic process was successfully applied in the wastewater degradation of textile industry too. The results have shown 95%, 97% and 100% of color removal for orange, ruby e red disperse dyes concomitant to reduction of 62,7%; 43,3% e 61,3% TOC values, respectively. Two wastewater was analyzed and the results present 80-89% of color removal, 49,8% and 46,8% of TOC removal and 50% of COD after 360 min of photoeletrocatalytic treatment. The reduction of bromate to bromide was also followed by photoeletrocatalytic treatment testing 0.25 mg L-1 of bromate in NaCl using Ti/TiO2 electrode, UV irradiation and potential of - 0.2V. The method has shown 65% of bromate concentration reduction after 75 min of treatment. / Doutor
247

Eletroanálise e oxidação fotoeletrocatalítica dos disruptores endócrinos bisfenol A e nonilfenol sobre eletrodo de nanotubos de 'TI'/'TI''O IND.2' auto-organizados /

Brugnera, Michelle Fernanda. January 2009 (has links)
Orientador: Maria Valnice Boldrin / Banca: Valdir Souza Fereira / Banca: Mauro Bertotti / Resumo: O presente trabalho propõe um método eletroanalítico para determinação dos disruptores endócrinos bisfenol A e nonilfenol em meio micelar utilizando-se eletrodos de carbono vítreo (ECV) e eletrodos de carbono impresso (ECI). Estes disruptores endócrinos têm levantado grande preocupação pois podem promover alterações no sistema endócrino e nível hormonal de humanos, além de sérios efeitos adversos nos organismos aquáticos, mesmo em baixas concentrações. A oxidação do grupo fenólico nos compostos BPA e NP ocorre em potencial 0,42 e 0,56 V, respectivamente em eletrodo de carbono vítreo e em 0,29 e 0,25V para eletrodo de carbono impresso. Curvas voltamétricas obtidas na presença de surfactante brometo de cetiltrimetilamônio (CTAB) têm mostrado maior intensidade de corrente, curvas melhores definidas e minimização dos efeitos de envenenamento da superfície do eletrodo provocado pela adsorção do produto oxidado. Usando-se as melhores condições otimizadas para a determinação de BPA: eletrólito suporte tampão BR pH 8, relação [CTAB]/[BPA] = 2:1 (mol L-1), com os parâmetro de VOQ: f= 60 Hz, Es= 6 mV e Esw= 50 mV e para NP : eletrólito suporte tampão BR pH 11, relação [CTAB]/[NP] = 1:2 (mol L-1), com os parâmetro de VOQ: f= 80 Hz, Es= 6 mV e Esw= 50 mV, construiu-se as curvas analíticas para BPA no intervalo de 1x10-6 a 1x10-5 mol L-1, obtendo-se os limites de detecção e quantificação 7,1x10-7 e 2,4x10-7 mol L-1, respectivamente, em ECV e no intervalo de 3x10-7 a 5x10-6 mol L-1, com LD= 1,1x10-7 mol L-1 e LQ= 3,7x10-7 mol L-1 em ECI. Para NP a curva construida utilizando-se ECV apresentou uma relação linear entre 1x10-9 e 1x10-7 mol L-1, LD= 9,0x10-10 mol L-1 e LQ=2,9x10-9 mol L-1 e em ECI uma relação linear entre 1x10-9 e 4x10-7 mol L-1, LD= 1,0x10-9 mol L-1 e LQ= 3,3x10-9 mol L-1. O método proposto foi aplicado na determinação desses em águas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This paper proposed an electrochemical method for determination of endocrine disruptors bisphenol A and nonylphenol in micellar media using glassy carbon (GCE) and screen printed electrodes (SPE). This endocrine disruptors can promote changes in the endocrine system and hormone levels in humans, and serious adverse effects on aquatic organisms, even at low concentrations. The oxidation of phenolic group of this compounds BPA and NP occurs in potential at 0.42 and 0.56 V, respectively in ECV and at 0.29 and 0.25 V in SP. The hydrophobic film of CTAB positively charged on the electrode surface promotes both preconcentration of NP and acts as antifouling agent facilitating the removal of its oxidized product that usually passivates the electrode surface. Using the best experimental conditions for BPA: B-R buffer pH8, ratio of [CTAB]/[BPA] = 2:1 (mol L-1), parameters SWV: f= 60 Hz, Es= 6 mV and Esw= 50 mV an for NP: B-R buffer pH 11, ratio of [CTAB]/[NP] = 1:2 (mol L-1), parameters SWV: f= 80 Hz, Es= 6 mV e Esw= 50 mV, the linear calibration graphs were constructed for BPA from 1.0x10-6 to 1.0x10-5 mol L-1 with detection limit of 7.1x10-7 mol L-1 and quantification of 2,4 x10-7 mol L-1 in GCE and from 3.0x10-7 to 5.0x10-6 mol L-1, with LOD= 1.1x10-7 mol L-1 and LOQ= 3.7 x10-7 mol L-1 in SPE. For NP the linear calibration graphs were constructed from 1.0x10-9 to 1.0x10-7 mol L-1, LOD= 9.0x10-10 mol L-1 and LOQ=2.9x10-9 mol L-1 in GCE and from 1.0x10-9 to 4.0x10-7 mol L-1, LOD= 1.0x10-9 mol L-1 and LOQ= 3.3x10-9 mol L-1 in SPE. The electroanalytical method developed was applied for analysis of these compounds in river water and sewage without prior treatment and the results were very satisfactory.A chromatographic method HPLC/DAD was also developed for the determination of BPA and NP. The best conditions were established as mobile-phase acetonitrile/water and flow rate 0.8 mL min-1... (Complete abstract click electronic access below) / Mestre
248

Estudo do comportamento do eletrodo de vidro combinado em etanol anidro e misturas etanol-água /

Silva, Ricardo Moutinho da. January 2009 (has links)
Resumo: Os estudos realizados do comportamento do eletrodo de vidro combinado em etanol anidro e misturas etanol-água mostraram que o tempo para realizar as medidas dos valores de pH foi 60 segundos, uma vez que a partir desse tempo nota-se uma tendência à estabilidade dos valores das medidas do pH. Foi também verificado que as medidas de pH em meio básico se diferenciam do meio ácido, sendo que a composição etanol-água tem influência significativa sobre os valores medidos e que a adição de eletrólito contribui para medidas de pH com desvios padrões menores. Os estudos da determinação dos fatores de correção para eletrodo de vidro mostram que os resultados obtidos estão próximos aos previstos. Por outro lado, na determinação desses fatores na região de pH compreendida entre 6 e 9, os resultados obtidos mostram que não é possivel a sua aplicação em amostras reais de etanol combustível. Para aplicação em amostras reais de etanol combustível, propõe-se um método alternativo utilizando curvas de correção que apresentaram relações lineares com coeficientes de correlação de 0,99 para misturas contendo 0,3, 5 e 10% m/m de água em etanol, proporções as quais se aproximam do etanol combustível anidro e hidratado. / Abstract: Studies of the behavior of a combined glass electrode in anhydrous ethanol and ethanol-water mixtures showed that 60 s was a enough time to perform the pH measurements, since for times equal and greater than 60 s the pH values tend to be stable. For all ethanol-water mixtures the behavior of pH measurements in alkaline medium was very different from that observed in the acidic one, and the ethanol-water composition had a significant influence on the pH values. The addition of electrolyte to the water-ethanol mixture contributed to decrease standard deviations of the pH values. Studies for determining the correction factors for the glass electrode showed values near the expected ones. Furthermore, the determination of these factors in the pH 6 to 9 region showed that they are not applied for real samples of ethanol fuel. For application in real samples of ethanol fuel an alternative method of correction was proposed using linear curves which showed correlation coefficients around 0.99 for mixtures containing 0.3, 5 and 10% m/m of water in ethanol. These mixtures are close to the anhydrous and hydrated ethanol fuel composition. / Orientador: Nelson Ramos Stradiotto / Coorientador: Paulo Paschoal Borges / Banca: Assis Vicente Benedetti / Banca: Marcelo Firmino de Oliveira / Mestre
249

Desenvolvimento de métodos analíticos para determinação de tetraciclina, doxiciclina, azitromicina, norfloxacina e ciprofloxacina em formulações farmacêuticas /

Rufino, José Luiz. January 2009 (has links)
Resumo: Neste trabalho foram desenvolvidos métodos analíticos com detecção espectrofotométrica na região visível para determinação de tetraciclina, doxiciclina, azitromicina, norfloxacina e ciprofloxacina em formulações farmacêuticas. As condições experimentais envolvidas em cada método foram cuidadosamente estudadas e otimizadas utilizando métodos multivariados (planejamentos fatoriais e metodologia de superfície de resposta), assim como método univariado. Para a determinação de tetraciclina e doxiciclina foi proposto método baseado na reação entre cloramina-T e os fármacos em meio alcalino de Na2CO3, produzindo compostos com coloração vermelha e absorbâncias em 535 e 525 nm para os produtos das reações da tetraciclina e doxiciclina, respectivamente. Posteriormente, este método foi automatizado utilizando sistema de análise por injeção em fluxo. Para a determinação de azitromicina foi proposto um método automatizado utilizando análise por injeção em fluxo com zonas coalescentes. O método é baseado na reação entre o fármaco e p-cloranil em meio metanólico na presença de H2O2 com formação de um complexo de transferência de carga de coloração roxa, o qual apresenta absorção em 540 nm. Para a determinação de norfloxacina e ciprofloxacina foi empregado um método utilizando análise por injeção sequencial. O referido método baseia-se na reação entre os fármacos e p-dimetilaminocinamaldeído em meio ácido (HCl) e micelar (sulfato de dodecil sódio). O produto formado apresentou coloração alaranjada com absorbância máxima em 495 nm. As substâncias comumente utilizadas como excipientes nas respectivas formulações farmacêuticas não interferiram nos métodos propostos. Todos os métodos propostos neste trabalho foram aplicados com sucesso na determinação destes fármacos em formulações farmacêuticas. Os resultados obtidos por estes... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this work were developed analytical methods with spectrophotometric detection in the visible region for tetracycline, doxycycline, azithromycin, norfloxacin and ciprofloxacin determination in pharmaceutical formulations. The experimental conditions involved in each method were carefully studied and optimized utilizing multivariate methods (design factorials and response surface methodology), as well as univariated method. For the tetracycline and doxycycline determination was proposed method based in the reaction between chloramine-T and the drugs in alkaline medium of Na2CO3 producing red color compounds with absorbance in 535 and 525 nm for the products of the reactions of tetracycline and doxycycline, respectively. Subsequently, this method was automated utilizing system of flow injection analysis. For the determination of azithromycin was proposed a method utilizing flow injection analysis with coalescent zones. The method is based in the reaction between the drug and p-chloranil in methanol medium in the presence of H2O2 with formation of a purple color charge-transfer complex, which presents absorption in 540 nm. For norfloxacin and ciprofloxacin determination was employed a method utilizing sequential injection analysis. The referred method based itself in the reaction between the drugs and p-dimethylaminocinnamaldehyde in acid (HCl) and micelar (sulphate of dodecil sodium) medium. The formed product presented orange color with maximum absorbance in 495 nm. The common excipients used as additives in the respective pharmaceutical formulations do not interfere in the proposed methods. All the proposed methods in this work were applied successfully to the determination of these drugs in pharmaceutical formulations. The analytical results obtained by applying the proposed methods compared very favorably with those obtained by the official or comparative methods, at 95% confidence level. / Orientador: Leonardo Pezza / Coorientador: Helena Redigolo Pezza / Banca: Clóvis Augusto Ribeiro / Banca: Matthieu Tubino / Banca: Ivo Milton Raimundo Junior / Banca: Carlos Roberto Bellato / Doutor
250

Desenvolvimento de métodos analiticos para determinação de 'CD', 'CU','NI'e 'PB' em biodiesel por espectrometria de absorção atômica em forno de grafite /

Lobo, Fabiana Aparecida. January 2009 (has links)
Orientador: André Henrique Rosa / Banca: Leonardo Fernades Fraceto / Banca: Edenir Rodrigues Pereira Filho / Banca: Marco Aurélio Zezzi Arruda / Banca: Cléssia Cristina Nascentes / Resumo: O biodiesel, também conhecido como diesel vegetal, é um combustível obtido de fonte renovável, considerado ambientalmente atraente e uma ótima alternativa em substituição ao diesel. Porém, contaminantes inorgânicos podem estar presentes em amostras de biodiesel devido à absorção de metais pela própria planta (matériaprima) do solo, e/ou podem ser incorporados durante o processo de produção/ transporte/estocagem. Desta forma, por meio de um controle analítico dos teores de contaminantes inorgânicos é possível gerenciar a qualidade dos combustíveis e avaliar o impacto ambiental destes. Este trabalho propõe o desenvolvimento de métodos analíticos para a determinação de Cu, Cd, Ni e Pb em amostras de biodiesel por espectrometria de absorção atômica em forno de grafite (GFAAS). Os procedimentos univariados e multivariados foram aplicados na avaliação das temperaturas ótimas de pirólise e atomização. O planejamento experimental foi usado também como ferramenta para a investigação de dois modificadores químicos (Pd + Mg e W) e dois diferentes procedimentos de preparo das amostras (amostras na forma de microemulsão e amostras digeridas por via úmida em sistema de microondas com radiação focalizada). Considerando que ao usar planejamento fatorial há um melhor entendimento das variáveis e das relações entre elas, os resultados usando o planejamento fatorial foram escolhidos para a determinação dos analitos nas amostras reais de biodiesel. Optou-se por trabalhar com W, pois os as determinações são mais rápidas, há poucos problemas relacionados ao background, durante a deposição do modificador na superfície do atomizador, as impurezas voláteis do modificador podem ser eliminadas, melhorando os limites de detecção, além do W ser um modificador permanente, o que pode aumentar o tempo de vida útil do atomizador. Os procedimentos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Biodiesel, also known as vegetable diesel, is a fuel obtained from a renewable source and an excellent alternative to diesel. However, biodiesel samples may contain inorganic contaminants due to the plant's (raw material) absorption of metals in the soil, and/or be incorporated during production, transportation or storage. Therefore, based on the analytical control of the inorganic contaminant content, it is possible to manage the quality of fuels and evaluate their environmental impact. This work proposes the development of analytical methods for the determination of Cu, Cd, Ni and Pb in biodiesel samples using graphite furnace atomic absorption spectrometry (GFAAS). Univariate and multivariate procedures were applied in the evaluation of the optimal temperatures of pyrolysis and atomization. Experimental design was also used as a tool in the investigation of two chemical modifiers (Pd + Mg and W) and two different sample preparation procedures (microemulsions and wet digestion in a focused microwave system). Using a factorial design there is better understanding of variables and relations between them and the results using the factorial design were chosen for the determination of analytes in real samples of biodiesel. Therefore, it was decided to work with W, since the heating programs are faster, there are few background problems, the volatile impurities of the modifier can be eliminated during its deposition on the surface of the atomizer, improving the detection limits, and W is a permanent modifier, which may help prolong the service life of the atomizer. The developed analyticals procedures may also be considered satisfactory as were good values of recovery and low standard deviations for all analytes measured in samples of biodiesel. This work contributes to establish or to propose a suitable normalization, since there is not yet in the literature and / or legislation... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0671 seconds