• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1324
  • 195
  • 124
  • 74
  • 16
  • 16
  • 15
  • 15
  • 13
  • 8
  • 3
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 1747
  • 1212
  • 470
  • 300
  • 259
  • 249
  • 211
  • 211
  • 186
  • 183
  • 173
  • 152
  • 129
  • 116
  • 115
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Desenvolvimento de metodologia eletroanalítica para a determinação de Imipramina em formulações comerciais utilizando eteltrodo de diamante dopado com Boro / Development of electroanalytical methodology for the determination of imipramine in commercial formulations using eteltrodo boron-doped diamond

Oliveira, Sâmeque do Nascimento January 2010 (has links)
OLIVEIRA, S. N. Desenvolvimento de metodologia eletroanalítica para a determinação de Imipramina em formulações comerciais utilizando eteltrodo de diamante dopado com Boro. 2010. 67 f. Dissertação (Mestrado em Química) - Centro de Ciências, Universidade Federal do Ceará, Fortaleza, 2010. / Submitted by Daniel Eduardo Alencar da Silva (dealencar.silva@gmail.com) on 2014-11-28T19:49:07Z No. of bitstreams: 1 2010_dis_snoliveira.pdf: 3305239 bytes, checksum: f64d54b3dd24c44341025e2620971c5b (MD5) / Approved for entry into archive by José Jairo Viana de Sousa(jairo@ufc.br) on 2016-01-29T19:50:48Z (GMT) No. of bitstreams: 1 2010_dis_snoliveira.pdf: 3305239 bytes, checksum: f64d54b3dd24c44341025e2620971c5b (MD5) / Made available in DSpace on 2016-01-29T19:50:49Z (GMT). No. of bitstreams: 1 2010_dis_snoliveira.pdf: 3305239 bytes, checksum: f64d54b3dd24c44341025e2620971c5b (MD5) Previous issue date: 2010 / This research describes the development of an electroanalytical procedure proposal for the determination of tricyclic antidepressant imipramine (IMP) in commercial pharmaceutical formulations, using Boron-Doped Diamond Electrode (BDDE) and Square-Wave Voltammetry (SWV). The electrochemical oxidation of imipramine was studied in 0.04 mol L-1 Britton-Robbinson buffer solution (BR). The results using VOQ showed two well-defined oxidation peaks with potentials of 0.04 V and 0.82 V versus Ag/AgCl/Cl- 3 mol L-1 for peaks 1 and 2, respectively. For the studies’ development was used the peak 1 because it demonstrated to be more sensitive and selective. The effect of the experimental and voltammetric parameters were evaluated and the best performance was obtained in pH 7.4, pulses application frequency of potential of 100 s-1, potential increment of 2 mV and amplitude of 50 mV. Under these conditions, the analytical curves were obtained in the linear range of concentration from 1.73 x 10-7 mol L-1 to 2.53 x 10-6 mol L-1 (r = 0,9984), with detection and quantitation limits 4.35 x 10-8 mol L-1 e 1.45 x 10-7 mol L-1, respectively. The proposed method was applied with success in the determination of IMP in commercial pharmaceutical formulations and validated by comparison with standard method for determination of imipramine. The obtained results were in close agreement, at a 95% confidence level, with those obtained using an official method of the British Pharmacopoeia. / Este trabalho descreve o desenvolvimento de uma proposta de procedimento eletroanalítico para a determinação do antidepressivo tricíclico imipramina (IMP) em formulações farmacêuticas comerciais, utilizando eletrodo de diamante dopado com boro (EDDB) e voltametria de onda quadrada (VOQ). Os estudos da oxidação eletroquímica da IMP foram realizados em solução de tampão Britton-Robbinson (BR) 0,04 mol L-1. Os resultados utilizando VOQ mostraram dois picos de oxidação bem definidos, com pico 1 em 0,04 V e pico 2 em 0,82 V versus Ag/AgCl/Cl- 3 mol L-1. Para o desenvolvimento dos estudos foi utilizado o pico 1 por ter se apresentado mais sensível e seletivo. O efeito dos parâmetros experimentais e voltamétricos foram avaliados e as melhores condições foram obtidas em pH 7,4, frequência de aplicação de pulsos de potencial de 100 s-1, incremento de potencial de 2 mV e amplitude de 50 mV. Sob estas condições, foram construídas curvas analíticas com resposta linear na faixa de concentração de 1,73 x 10-7 mol L-1 a 2,53 x 10-6 mol L-1 (r = 0,9984), com um limite de detecção e de quantificação de 4,35 x 10-8 mol L-1 e 1,45 x 10-7 mol L-1, respectivamente. O método proposto foi aplicado com sucesso na determinação de IMP em formulações farmacêuticas comerciais e validado por comparação com método padrão de determinação de imipramina. Os resultados obtidos estiveram de acordo, em um nível de confiança de 95%, com aqueles obtidos usando o método oficial da Farmacopéia Britânica.
202

Avaliação da contaminação antrópica por metais no sedimento de fundo na bacia do igarapé do Educandos, Manaus, Amazonas

TORREZANI, Larissa January 2016 (has links)
Submitted by Teresa Cristina Rosenhayme (teresa.rosenhayme@cprm.gov.br) on 2017-01-10T17:26:21Z No. of bitstreams: 1 Dissertação Larissa versão final.pdf: 2359193 bytes, checksum: 60fddfa2c6835973a534334a6a2cfbbf (MD5) / Approved for entry into archive by Flasleandro Oliveira (flasleandro.oliveira@cprm.gov.br) on 2017-01-10T17:58:27Z (GMT) No. of bitstreams: 1 Dissertação Larissa versão final.pdf: 2359193 bytes, checksum: 60fddfa2c6835973a534334a6a2cfbbf (MD5) / Approved for entry into archive by Flasleandro Oliveira (flasleandro.oliveira@cprm.gov.br) on 2017-01-10T17:59:22Z (GMT) No. of bitstreams: 1 Dissertação Larissa versão final.pdf: 2359193 bytes, checksum: 60fddfa2c6835973a534334a6a2cfbbf (MD5) / Made available in DSpace on 2017-01-10T17:59:27Z (GMT). No. of bitstreams: 1 Dissertação Larissa versão final.pdf: 2359193 bytes, checksum: 60fddfa2c6835973a534334a6a2cfbbf (MD5) Previous issue date: 2016
203

DOIS RELATOS, DUAS ONÇAS, TRÊS GÊNEROS: Meu tio o iauaretê e O espelho, de João Guimarães Rosa

BARCELLOS, T. D. F. 12 February 2015 (has links)
Made available in DSpace on 2016-08-29T14:11:31Z (GMT). No. of bitstreams: 1 tese_8563_DISSERTAÇÃO THAÍS DAMASCENO FELIX BARCELLOS.pdf: 637742 bytes, checksum: 0558759253f643ca11907aa0f1476189 (MD5) Previous issue date: 2015-02-12 / Em nossa Dissertação de Mestrado, estudaremos, sobretudo, Meu tio o iauaretê, de Estas estórias, e, ainda, O espelho, de Primeiras estórias, de João Guimarães Rosa. Estes são os objetivos gerais do presente trabalho. Em relação ao primeiro relato (uma narrativa mais longa), temos como propósito específico efetuar a sua análise por meio da teoria do gênero fantástico desenvolvida por Tzvetan Todorov, a qual leva em conta os gêneros estranho e maravilhoso. Em relação ao segundo (uma narrativa bem menos extensa), o nosso intento específico é a sua abordagem a partir do maravilhoso. Também lançaremos mão de conceitos da psicologia analítica de Carl Gustav Jung, na leitura de ambos os textos: noções como inconsciente coletivo, arquétipo, anima, animus, alma do mato (para Meu tio o iauaretê), si-mesmo ou self, persona e sombra (para O espelho). Não pretendemos, todavia, transformar os personagens das duas obras em casos clínicos, mas mostrar como aspectos da teorização junguiana, tal como ocorre com a de Freud, servem para iluminar a produção literária de um modo geral. Dois detalhes que funcionam como fatores de ligação das duas narrativas de Rosa são as presenças da figura da onça e do espelho nas páginas de ambas.
204

Desenvolvimento, validação e adequação de metodologias analíticas empregando cromatografia líquida de alta eficiência para determinação de pemetrexede, fludarabina e idarrubicina-hcl em liófilos injetáveis

Dotse, Louis Kwame 14 December 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências Farmacêuticas, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2018-04-16T18:33:25Z No. of bitstreams: 1 2017_LouisKwameDotse.pdf: 1361333 bytes, checksum: 9494aa08cdf72b04277d6d198a1f4c4e (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-05-08T16:48:47Z (GMT) No. of bitstreams: 1 2017_LouisKwameDotse.pdf: 1361333 bytes, checksum: 9494aa08cdf72b04277d6d198a1f4c4e (MD5) / Made available in DSpace on 2018-05-08T16:48:47Z (GMT). No. of bitstreams: 1 2017_LouisKwameDotse.pdf: 1361333 bytes, checksum: 9494aa08cdf72b04277d6d198a1f4c4e (MD5) Previous issue date: 2018-05-08 / Este trabalho teve por objetivo o desenvolvimento e validação de um método analítico simples e sensível para a determinação de Pemetrexede em pó liofilizado, por meio da técnica de cromatografia liquida de alta eficiência (CLAE-UV), além da adequação das metodologias analíticas vigentes na Farmacopeia americana (USP) para Fludarabina e Idarrubicina, todos princípios ativos de medicamentos antineoplásicos aprovados para o tratamento de canceres. Para o desenvolvimento do método, utilizou -se a coluna C18 (250 x 4,6 mm; 5 µm), comprimento de onda de detecção de 254 nm à temperatura ambiente (25°C). A composição da fase móvel foi de acetonitrila (ACN): solução tampão de fosfato monobásico de sódio pH 4 (30:70) com vazão de 0,8 ml/min por meio de eluição isocrático, obtendo o tempo de retenção de 4,2min. A equação da curva analítica foi, y=37,55x+214,62, com r² = 0,99. O desvio padrão relativo foi 0,1%, com Limite de detecção (LOD) e limite de quantificação (LOQ) de 1,49 µg/mL e 4,53 µg/mL respetivamente. O método analítico desenvolvido foi aplicado com sucesso na determinação do teor de Pemetrexede em amostras de produtos farmacêuticos acabados obtendo-se boa precisão (desvio relativo de 0,3%). Nos ensaios de adequação do método para controle de qualidade dos medicamentos antineoplásicos Fludarabina e Idarrubicina, ambos os métodos mostraram boa linearidade (r²>0,99), seletividade e precisão (DPR≤2,0%). Os métodos estudados podem ser considerados simples, e capazes de avaliar a qualidade, eficácia e segurança em liófilos injetáveis de Pemetrexede, Fludarabina e Idarrubina. / The aim of this work was to develop and validate a simple, sensitive and cost-effective analytical method for the determination of Pemetrexed in lyophilized powder by means of the high-performance liquid chromatography (HPLC-UV) technique, besides evaluating the adequacy of analytical methods present in United States Pharmacopoeia (USP) belonging to Fludarabine and Idarubicin, active ingredients in antineoplastic drugs approved for the treatment of various cancers. The method was developed employing C18 Column (250 x 4,6 mm; 5 µm), with absorbance wavelength measured at 254 nm, at column oven temperature of 25°C, with mobile phase composed of acetonitrile ACN: sodium dihydrogen orthophosphate buffer of pH 4 (30:70) at a flow rate of 0,8ml/min in isocratic elution, obtaining a retention time of 4.2mins. the method proved to be linear with r² >0.99, a curve equation of y=37,55x+214,62, of relative standard deviation of 0.1%, with limit of detection (LOD) and limit of quantification LOQ of 1,49 µg/mL e 4,53 µg/mL respectively the developed method was then used in the determination of Pemetrexede in bulk pharmaceutical formulations obtaining (relative deviation of 0,3%). Tests evaluating the adequacy of quality control methods for other antineoplastic agents such Fludarabina e and Idarubicin present in USP was also carried out, during which both methods tested demonstrated, precision (RSD≤2,0%), linearity (r²>0.99) and selectivity respectively. The studied method is simple, efficient and capable of determining the quality, quantity, efficacy and security of Pemetrexed, Fludarabine and Idarubicin in lyophilized powder for injection.
205

Determinação de enxofre em amostras agroindustriais por espectrometria de absorção molecular com fonte contínua e alta resolução /

Virgilio, Alex. January 2010 (has links)
Orientador: José Anchieta Gomes Neto / Banca: Joaquim de Araújo Nóbrega / Banca: Marcia Andréia Mesquita Silva da Veiga / Resumo: Foi desenvolvido e validado um método para determinação de enxofre em amostras agroindustriais por espectrometria de absorção molecular em chama com fonte contínua e alta resolução (HR-CS MAS), por meio da medida da absorção molecular do monosulfeto de carbono (CS) em 257,595; 257,958 e 258,056 nm e do hidreto de enxofre (SH) em 323,658; 324,064 e 327,990 nm, associados aos espectros com que possuem estruturas rotacionais finas comparáveis a linhas atômicas. Em chama acetileno-ar, a altura de observação ótima foi de 7 mm e razão da vazão dos gases para CS e SH de 0,211 e 0,231 com 110 L h-1 de acetileno. Para chama a acetileno-N2O, a altura ótima de observação para todas as linhas de CS foi 5 mm e para SH 12 mm em 323,658 nm e 6 mm para 324,064 nm e 327,990 nm. A condição ótima de chama foi de 250 L h-1 de acetileno (razão acetileno/ar 0,617) para CS e variável entre 190-220 L h-1 (razão 0,467-0,541) para as três linhas de SH. A natureza dos reagentes H2SO4 e (NH4)2SO4 no preparo dos padrões de enxofre foi avaliada com relação a produção das espécies CS e SH, apresentando influência insignificante. A influência da medida da absorbância integrada no comprimento de onda foi avaliada do pixel central (CP) até 7 pixels (CP±3), observando melhoria de sensibilidade com o aumento de pixels e correspondente diminuição da precisão. As principais figuras de mérito foram estabelecidas. Intervalos lineares entre 100-5000 mg L-1 S (CS) e 2000-40000 mg L-1 S (SH), limites de detecção entre 15,1-22,4 mg L-1 S (CS) e 955,8-2558,3 mg L-1 S (SH) e desvios padrão relativos inferiores a 5,7% (CS) e 8,5% (SH), foram obtidos utilizandose o (NH4)2SO4 na calibração e medidas para 1 pixel (CP). As linhas de CS se mostraram livres de interferências espectrais, enquanto que para SH... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: A method was developed and validated for sulfur determination in agroindustrial samples by high-resolution continuum source molecular absorption spectrometry in flame (HR-CS MAS), using the molecular absorption of the carbon monosulfide (CS) at 257.595; 257.958 and 258.056 nm and for sulfur hydride (SH) at 323.658; 324.064 and 327.990 nm, associated to sharp rotational structures comparable to atomic lines. In acetylene-air flame, the optimum burner height was of 7 mm and gases flow ratio for CS and SH of 0.211 and 0.231 with 110 L h-1 of acetylene. For acetylene-N2O flame, the optimum burner height for all CS lines was 5 mm and 12 mm at 323.658 nm and 6 mm for 324.064 and 327.990 nm for SH. The optimum flame condition was 250 L h-1 of acetylene (acetylene/air ratio 0.617) for CS and variable between 190-220 L h-1 (ratio 0.467-0.541) for SH. The characteristics of the reagents H2SO4 and (NH4)2SO4 in the preparation of sulfur standard solutions were evaluated to product the CS and SH species, and their influence were insignificant. The influence of wavelength integrated absorbance was evaluated measuring the central pixel (CP) up to 7 pixels (CP±3). This procedure improved the sensibility but reduced the precision when the number of pixels evaluated was increased. The main figures of merit were established. Linear dynamic ranges between 100-5000 mg L-1 S (CS) and 2000-40000 mg L-1 S (SH), limits of detection between 15.1-22.4 mg L-1 S (CS) e 955.8-2558.3 mg L-1 S (SH) and relative standard deviations less than 5.7% (CS) e 8.5% (SH), were obtained using (NH4)2SO4 in calibration and 1 pixel (CP) evaluation. The CS lines presented free of spectral interferences, but for SH at 323.658 nm in presence of some elements like Ca, Cu, Fe, Mn, P, Si, Zn, this interferences were considerable. The performance of fungicide samples prepare in closed vessel microwave-assisted acid-digestion system was... (Complete abstract click electronic access below) / Mestre
206

Integração de uma coluna redutora à um microdispositivo fluídico e avaliação de sistemas miniaturizados na determinação de nitrito, nitrato e fosfato em águas naturais

Nóbrega, Lorrana Nara Naves 21 June 2013 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Química, Programa de Pós-Graduação em Química, 2013. / Submitted by Larissa Stefane Vieira Rodrigues (larissarodrigues@bce.unb.br) on 2014-11-03T16:28:05Z No. of bitstreams: 1 2013_LorranaNaraNavesNóbrega.pdf: 3512692 bytes, checksum: 6d3a4a9f33fd9e06e8dc8f8c3cc466a8 (MD5) / Approved for entry into archive by Tania Milca Carvalho Malheiros(tania@bce.unb.br) on 2014-11-03T16:46:16Z (GMT) No. of bitstreams: 1 2013_LorranaNaraNavesNóbrega.pdf: 3512692 bytes, checksum: 6d3a4a9f33fd9e06e8dc8f8c3cc466a8 (MD5) / Made available in DSpace on 2014-11-03T16:46:16Z (GMT). No. of bitstreams: 1 2013_LorranaNaraNavesNóbrega.pdf: 3512692 bytes, checksum: 6d3a4a9f33fd9e06e8dc8f8c3cc466a8 (MD5) / Este trabalho descreve o desenvolvimento e a avaliação de microssistemas de análise por injeção em fluxo (µFIA) para as determinações de nitrito (NO2-), nitrato (NO3-), e fosfato (PO4-3) em águas doces. Para todos os µFIA, a fotolitografia profunda no ultravioleta foi empregada para fabricação dos dispositivos a partir de um fotorresiste a base de uretana-acrilato (UA). Todos os dispositivos apresentaram dimensões tão pequenas quanto à de um cartão de crédito (7,0 cm x 4,0 cm x 0,5 cm) e canais de formato em “U” com até 390 μm de profundidade. Um procedimento simples e de baixo custo foi utilizado para a integração de uma coluna redutora de cádmio ao FIA de NO3-, por meio da inserção manual de grânulos de cádmio selecionados (0,5 a 1,0 mm) à um reservatório dedicado (1,00 mm x 0,65 mm x 20 mm). A coluna demonstrou bom desempenho com 97,5% de eficiência de redução (NO3- para NO2-) e ausência de vazamentos para vazões superiores a 2,0 mL min-1. Os sinais analíticos transientes obtidos com os microssistemas propostos apresentaram razões sinal/ruído satisfatórias e permitiram ajustes lineares (R > 0,99) para as faixas de concentração estudadas (0,06 a 0,37 mg N L-1 (NO2-); 0,23 a 2,26 mg N L-1 (NO3-) e 1,0 a 8,0 mg P L-1 (PO4-3)) sendo estimados os limites de detecção de 0,15 mg N L-1 (NO3-), 0,03 mg N L-1 (NO2-) e 0,54 mg P L-1 (PO4-3). Para as determinações de NO3- e NO2- as figuras de mérito estimadas demonstraram adequação a regulamentação brasileira para águas doces. Empregando-se amostras de águas doces superficiais e/ou amostras de águas comerciais, recuperações de 90,4 % a 114,7 % foram obtidas e não foram observadas diferenças significativas (95% de confiança) entre os valores determinados com os microssistemas e aqueles determinados a partir de métodos de referência, demonstrando uma boa exatidão dos procedimentos. Para todas as determinações, reduções significativas no consumo de reagentes e na geração de resíduos foram observadas em relação aos sistemas de análise por injeção em fluxo usuais, demonstrando que os dispositivos propostos atendem aos preceitos da química verde. ______________________________________________________________________________ ABSTRACT / This work describes the development and evaluation of flow injection analysis (µFIA) microsystems for nitrite (NO2-), nitrate (NO3-), and phosphate (PO4-3) determinations in fresh waters. For all µFIA, deep ultraviolet photolithography was used for fabrication of the devices using a photoresist based on urethane acrylate (UA) photoresist. All devices present dimensions as small as a credit card (7.0 cm x 4.0 cm x 0.5 cm) and "U" shape channels with up to 390 μm deep. A simple and inexpensive procedure was used for the integration of a cadmium reduction column to the µFIA applied for NO3- determination by using manual insertion of selected cadmium particles (0.5 to 1.0 mm) into a dedicated reservoir (1.00 mm x 0.65 mm x 20 mm). The column presented a good performance with an efficiency of reduction of 97,5% (NO3- to NO2-) and no leaks for flow rates higher than 2.0 mL min-1. The proposed microsystem showed adequate signal to noise ratios and provided linear relationships (R> 0,99) for the concentration range studied (0.06 to 0.37 mg L-1 N (NO2-), 0.23 to 2.26 mg L-1 N (NO3-) and 1.0 to 8.0 mg L-1 P (PO4-3)) with estimated detection limits of 0.15 mg L-1 N (NO3 -), 0.03 mg L-1 N (NO2-) and 0.54 mg L-1 P PO4-3). For the determination of NO3- and NO2-, the estimated figures of merit were adequate to Brazilian regulations for freshwater. By employing the proposed devices to fresh superficial water samples and/or commercial water samples, recoveries of 90.4% to 114.7% were obtained and no significant differences were observed (95% confidence) between the values determined with microsystems and those determined from reference methods, demonstrating good accuracy of the procedures. For all determinations, significant reductions in reagent consumption and waste generation were observed when compared to usual flow injection analysis systems demonstrating that the proposed devices are appropriate to the principles of green chemistry.
207

Otimização das características funcionais de produtos saneantes através de planejamento de experimentos / Optimization of the functional characteristics of sanitizing products through an experimental design

Ochoa, Douglas Herlemann 07 August 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Química, Programa de Pós-Graduação em Química, 2014. / Submitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2014-12-02T14:29:00Z No. of bitstreams: 1 2014_DouglasHerlemannOchoa.pdf: 4464147 bytes, checksum: 10f9d24810753d707dbb810dd8e7c907 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-12-02T15:31:28Z (GMT) No. of bitstreams: 1 2014_DouglasHerlemannOchoa.pdf: 4464147 bytes, checksum: 10f9d24810753d707dbb810dd8e7c907 (MD5) / Made available in DSpace on 2014-12-02T15:31:28Z (GMT). No. of bitstreams: 1 2014_DouglasHerlemannOchoa.pdf: 4464147 bytes, checksum: 10f9d24810753d707dbb810dd8e7c907 (MD5) / A pesquisa e o desenvolvimento das indústrias do setor de higiene e limpeza pessoal e cosméticos não atende plenamente à necessidades do mercado. Normalmente, em realidades de pequenas e médias empresas, os departamentos de pesquisa e desenvolvimento costumam copiar formulações da concorrência ou adotar formulações disponibilizadas por fornecedores. Desta forma o trabalho desenvolvido por estes departamentos acaba se tornando uma atividade sem inovações e sem preocupações com a relação custo / benefício dos produtos desenvolvidos. Buscando otimizar a formulação referencial de lava-louças comercial, empregou-se o planejamento fatorial fracionário, aliado ao planejamento de misturas com o objetivo de obter melhores propriedades do produto final e relações de custo / benefício para a formulação referencial, bem como, gerar informações que possam ser úteis aos setores de limpeza pessoal, doméstica, institucional e industrial. Inicialmente, foi realizado um planejamento fatorial fracionário para determinar quais foram os efeitos significativos para cada variável de resposta: viscosidade, desempenho, espumação e temperatura de névoa. Em seguida, utilizou-se o planejamento de misturas para determinar quais seriam as composições que apresentam os melhores resultados de cada propriedade de interesse. Foi possível determinar composições que atendem ao requisito com confiança de resultados na ordem de 90 %, mostrando que melhorias de composição podem ser adotadas. Com base nas formulações de mercado foi possível estimar composições que atendam ao mesmo custo por quilograma de produto porém com ganhos de detergência, volume de espumação e viscosidade. ________________________________________________________________________________ ABSTRACT / The research and development of the cosmetics and personal hygiene and cleaning sector industries not fully meet the needs of the market. Normally, in situations of small and medium companies, research and development departments often copy the market formulations or adopt formulations provided by suppliers. Thus the work of these departments eventually becomes an activity without innovation and without worrying about the cost / benefit ratio of developed products. To optimize the benchmark commercial dishwasher formulation, we used the fractional factorial design, coupled with the planning of mixtures in order to obtain better final product properties and relations of cost / benefit to the reference formulation, as well as generate information that may be useful to personal, domestic, institutional and industrial cleaning sectors. Initially, we performed a fractional factorial design to determine which were the significant effects for each response variable: viscosity, performance, foaming and fog temperature. Then, we used planning of mixtures to determine what are the compositions that feature the best results for each property of interest. We have determined compositions that meet the requirement with confidence results in the order of 90%, showing that improvements composition can be adopted. Based on the market formulations, it was possible to estimate compositions that meet the same cost per kilogram of product but with gains in detergency, foaming and viscosity volume.
208

Desenvolvimento de uma metodologia para comparação de amostras de sal de cocaína pela determinação de solventes residuais e análise quimiométrica

Grobério, Tatiane Souza 09 March 2012 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Química, 2012. / Submitted by Elna Araújo (elna@bce.unb.br) on 2012-07-06T23:05:47Z No. of bitstreams: 1 2012_TatianeSouzaGroberio.pdf: 5702868 bytes, checksum: 3a2c605b5b00df870b5ee8781d188fff (MD5) / Approved for entry into archive by Jaqueline Ferreira de Souza(jaquefs.braz@gmail.com) on 2012-07-09T12:03:42Z (GMT) No. of bitstreams: 1 2012_TatianeSouzaGroberio.pdf: 5702868 bytes, checksum: 3a2c605b5b00df870b5ee8781d188fff (MD5) / Made available in DSpace on 2012-07-09T12:03:42Z (GMT). No. of bitstreams: 1 2012_TatianeSouzaGroberio.pdf: 5702868 bytes, checksum: 3a2c605b5b00df870b5ee8781d188fff (MD5) / A produção de cocaína requer a utilização de solventes orgânicos que não são completamente removidos durante esse processo, deixando vestígios químicos que podem ser posteriormente analisados em laboratório e devidamente correlacionados ao local de origem, aos métodos de refino e à rota de tráfico. Esse tipo de informação é relevante à investigação policial, aos esforços de colaboração internacional no combate ao tráfico de drogas e para a definição de políticas governamentais em termos de segurança e saúde pública. Diversas técnicas instrumentais são capazes de identificar grande parte dos componentes presentes em amostras de cocaína, fornecendo informações a respeito dos solventes residuais que essas amostras contêm. A análise estatística apropriada dessas informações estabelece padrões que revelam as principais características químicas da amostra. Esse trabalho visou consolidar uma metodologia adequada à realidade brasileira que permitisse a análise rápida e confiável de amostras na forma de sal de cocaína. Para isso, a técnica utilizada na determinação de solventes residuais em amostras de sal de cocaína foi Headspace associada à Cromatografia Gasosa e detecção por Espectrometria de Massas (HS-GC-MS). A análise de dados empregou métodos como Análise de Componentes Principais (PCA) e Análise Hierárquica de Clusters (HCA). O quadrado da função cosseno foi utilizado como medida para correlação entre amostras. Através dos resultados obtidos por PCA foi possível classificar as amostras conforme o método de refino utilizado no processo de produção da cocaína. Estudos estatísticos apontaram valores limites que puderam discriminar amostras como sendo “ligadas”, ou seja, correlacionadas em relação à forma de produção, permitindo estabelecer ligações entre apreensões de cocaína efetuadas em todo o Brasil. A metodologia desenvolvida para essa discriminação pode ser considerada promissora, pois não necessita do conhecimento a priori da população de amostras e permite o ajuste dinâmico dos valores limites para diferentes conjuntos. _________________________________________________________________________________ ABSTRACT / Cocaine production requires the use of organic solvents that are not completely removed during this process, leaving chemical traces that can later be analyzed in the laboratory and properly correlated to drug origin, processing methods and trafficking route. Such information is relevant to police investigation, the efforts of international cooperation in combating drug trafficking and for the establishment of government policies in terms of safety and public health. Several instrumental techniques are able to identify most of the components present in cocaine samples, providing information about the residual solvents in these samples. The appropriate statistical analysis of this information establishes standards that reveal the main chemical characteristics of the sample. This work aimed to build an appropriate methodology to the Brazilian reality that allows rapid and reliable analysis of salt samples of cocaine. For this, the technique used in the determination of residual solvents in salt samples of cocaine was Headspace associated with Gas Chromatography and Mass Spectrometry detection (HS-GC-MS). The data analysis employed methods such as Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA). The square of the cosine function was used as a measure of correlation between samples. Based on the results obtained by PCA the cocaine samples were classified according to the method used in the refining process for cocaine production. Statistical studies showed that limiting values could discriminate samples as being linked, ie, correlated in relation to how the sample was producted, or non-linked. This result allows correlations between cocaine seizures made in Brazil. The proposed methodology can be consideres is promising for such discrimination, as priori knowledge of the sample population is not required and allows the dynamic adjustment of the limit values for different sets of samples.
209

Metabonômica baseada em RMN como ferramenta para discriminação de grãos de soja irradiados & diagnóstico de hepatites e fibrose hepática

BARROS, Carlos Jonnatan Pimentel 24 February 2017 (has links)
Submitted by Pedro Barros (pedro.silvabarros@ufpe.br) on 2018-08-07T17:56:23Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Carlos Jonnatan Pimentel Barros.pdf: 10392206 bytes, checksum: d2710939eaa548f991436632cb6f8178 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-08-15T20:52:10Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Carlos Jonnatan Pimentel Barros.pdf: 10392206 bytes, checksum: d2710939eaa548f991436632cb6f8178 (MD5) / Made available in DSpace on 2018-08-15T20:52:10Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Carlos Jonnatan Pimentel Barros.pdf: 10392206 bytes, checksum: d2710939eaa548f991436632cb6f8178 (MD5) Previous issue date: 2017-02-24 / CNPq / Neste trabalho, foram construídos modelos metabonômicos baseados na espectroscopia de ressonância magnética nuclear de hidrogênio (RMN de ¹H) e no emprego de técnicas de análise estatística multivariada para: discriminação entre grãos de soja expostos à radiação gama, com fins fitossanitários, e aqueles não irradiados; investigar e diferenciar portadores de hepatites virais (do tipo B ou C) de voluntários saudáveis; e classificar pacientes com hepatite C crônica, em função do grau de fibrose hepática. Para o trabalho usando grãos de soja, os extratos clorofórmicos dos mesmos foram analisados por RMN de ¹H e os modelos PCA e PLS-DA evidenciaram separação entre os grupos de amostras irradiadas e não irradiadas. Na validação cruzada total, o modelo PLS-DA apresentou uma exatidão de 100%, R² de 0,973 e Q² de 0,958. As variáveis discriminatórias mais importantes foram δ 1,57 e 1,62 ppm, que estão relacionadas aos grupos metilênicos β-carboxila de ésteres e dos ácidos carboxílicos livres, respectivamente. Nos estudos de casos de hepatites, foram analisados por RMN de ¹H amostras de soro e urina de pacientes portadores de hepatite B ou C e de voluntários saudáveis. Os modelos usando PCA ou PLS-DA construídos com o intuito de discriminar os três grupos analisados não apresentaram distinção entre os grupos. No entanto, para a discriminação entre o grupo dos pacientes com hepatites (B ou C) e o grupo controle, foram observadas tendências de separação nos modelos de PCA e PLS-DA, utilizando-se soro ou urina. Os melhores resultados foram obtidos usando amostras de soro. Na validação cruzada total, para o melhor modelo usando o formalismo PLS-DA apresentou exatidão de 80,2%, R² de 0,365 e Q² de 0,192. O formalismo LDA também foi utilizado e o modelo com as amostras de soro apresentou os melhores resultados, com sensibilidade de 92,3%, especificidade de 69,2%, valor preditivo positivo de 88,2% e valor preditivo negativo de 78,3%. Por fim, foram analisadas amostras de soro de pacientes com hepatite C crônica e diagnóstico de grau de fibrose, provenientes de dois grupos: amostras coletadas em Recife/PE e no Rio de Janeiro/RJ. Os modelos metabonômicos foram criados de forma a discriminar os diferentes graus de fibrose: fibrose avançada (F3 e F4) x fibrose não-avançada (F0, F1 e F2); fibrose significativa (F2, F3 e F4) x fibrose não-significativa (F0 e F1). Para as amostras de Recife/PE, usando o formalismo LDA, foram encontrados valores de exatidão maiores que 95%, em todos os modelos, utilizando validação cruzada. Amostras pertencentes ao grupo de fibrose intermediária (F2) foram encontradas a partir dos dois modelos anteriores com sensibilidade de 100%. As análises por PLS-DA também mostraram clara separação entre os grupos, e foram validadas por validação cruzada e teste de permutação. Para as amostras do Rio de Janeiro/RJ, as análises por LDA e PLS-DA mostraram resultados semelhantes. Os modelos construídos mostraram que a estratégia metabonômica pode ser empregada em diferentes segmentos, como agroindústria e medicina, com eficiências semelhantes. / In this work, we built metabonomics models based on proton nuclear magnetic resonance (¹H NMR) and for multivariate statistical analysis. These models were used to discriminate among gamma irradiated and non-irradiated soybean samples for phytosanitary purposes; for research and discriminate of viral hepatitis patients (type B or C) from healthy volunteers; and to classify the degree of liver fibrosis in hepatitis C patients. For the study with soybeans, chloroform extracts of the grains were analyzed by ¹H NMR and metabonomics models with PCA and PLS-DA showed separation between the irradiated samples and non-irradiated ones. In the leave one out cross validation (LOOCV), the PLS-DA model showed an accuracy of 100%, R² of 0.973 and Q² of 0.958. The most important discriminatory variables were δ 1,57 and 1,62 ppm, which are related to ester β -carboxyl methylene groups and carboxylic acids β -carboxyl methylene groups, respectively. In the viral hepatitis study, serum and urine from patients with B or C hepatitis and from healthy volunteers were analyzed by ¹H NMR. None of the PCA and PLS-DA models were able to discriminate among the three groups. On the other hand, discrimination between hepatitis (B or C) patients and the control group was more effective, with separation trends in the models using PCA and PLS-DA, with serum and urine. The serum models showed the best results. In the LOOCV, PLS-DA model was accurate to 80.2%, R² of 0.365% and Q² of 0.192. The LDA formalism was also used with the serum models showed the best results, with a sensibility of 92.3%, specificity of 69.2%, predictive positive value of 88.2% and predictive negative value of 78.3%. Finally, serum samples from patients with chronic hepatitis C and fibrosis stage diagnosis were analyzed, from two groups: samples collected in Recife/PE and in Rio de Janeiro/RJ. Metabonomic models were created to differentiate among the different degrees of fibrosis: advanced fibrosis (F3 and F4) x non-advanced fibrosis (F0, F1 and F2); significant fibrosis (F2, F3 and F4) x non-significant fibrosis (F0 and F1). The Recife/PE LDA models showed more than 95% accuracy for LOOCV. Samples with intermediate fibroses (F2) were found with sensibility of 100%. PLS-DA models also clearly discriminated among the groups, validated with LOOCV and permutation tests models. The LDA and PLS-DA models for the Rio de Janeiro/RJ samples had similar results. The metabonomics models demonstrate that this strategy can be used in different areas, such as agribusiness and medicine, with similar efficiency.
210

Alavancando Inovação de Processos Por Meio da Abordagem Analítica, Fato Ou Mito?

CAVALCANTI, C. X. 28 February 2014 (has links)
Made available in DSpace on 2018-08-01T23:40:34Z (GMT). No. of bitstreams: 1 tese_7522_Dissertação de Claudia.pdf: 1317892 bytes, checksum: f08ec439ad4779ff72f8cd7ede1de1b4 (MD5) Previous issue date: 2014-02-28 / Este trabalho de mestrado tem como objetivo principal investigar a intensidade em que a orientação analítica das empresas pode impactar nas inovações de processos. Esta pesquisa propõe também elaborar um conceito mais abrangente e consistente para um assunto ainda emergente no mundo acadêmico: o conceito sobre abordagem analítica, que na linguagem internacional é conhecido como Business Analytics (BA). A plataforma teórica utilizada se baseia nas discussões acerca do processo decisório e da inteligência competitiva. Na metodologia, foi aplicada a técnica de modelagem de equações estruturais para testaras relações estabelecidas no modelo estrutural proposto, onde foram considerados os constructos Habilidades Analíticas, Tecnologia Analítica, Qualidade de Dados, Comprometimento da Liderança, Estratégia analítica, Abordagem Analítica (BA) e Inovação de Processos. O trabalho de coleta de dados foi realizado através de uma base de dados de Clientes da empresa SAS no Brasil, uma das maiores empresas fornecedoras de soluções analíticas do mundo, com sede nos Estados Unidos e filiais espalhadas em todo mundo, o que proporciona ao trabalho uma maior consistência nos seus resultados. O estudo concluiu que a abordagem analítica (BA) tem um forte impacto na Inovação de Processos e que o constructo Estratégia possui uma grande relevância preditiva em BA.

Page generated in 0.0676 seconds