• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 5
  • 3
  • 2
  • 1
  • Tagged with
  • 25
  • 20
  • 15
  • 10
  • 10
  • 10
  • 7
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Συμπεριφορά απαγωγέων υπέρτασης σε γραμμές μεταφοράς σε πλήγματα κεραυνών

Πανούση, Αικατερίνη 15 April 2013 (has links)
Σκοπός της εργασίας είναι η μελέτη της συμπεριφοράς απαγωγέων υπέρτασης στις γραμμές μεταφοράς υψηλής τάσης όταν αυτές καταπονούνται από κεραυνικά πλήγματα. Γίνεται μοντελοποίηση πραγματικών πυλώνων και γραμμών του Ελληνικού συστήματος μεταφοράς, καθώς και αλεξικέραυνων, προσομοίωσή τους στο πρόγραμμα ATP/EMTP και στη συνέχεια μελέτη των υπερτάσεων που εμφανίζονται κατά τη διάρκεια κεραυνικών πληγμάτων πάνω στους αγωγούς προστασίας. / The purpose of this thesis is the study of the behavior of surge arresters on high voltage transmission lines when they are strained by lightning strikes. Steel towers and transmission lines used in the Greek Transmission System and also surge arresters are simulated with ATP/EMTP and the overvoltages that occur during lightning strikes on the shielding wires are studied.
12

A General Inception Criteria For The Positive Upward Leaders In Cloud-to-Ground Lightning

Prasanth Kumar, B 07 1900 (has links) (PDF)
No description available.
13

Estudo de metodologia para modelagem e simulação de tensões induzidas de origem atmosférica em linhas de distribuição protegidas por para-raios de \'ZN\'O\' / Study of methodology for modeling and simulation of induced voltages of atmospheric origin in distribution lines protected by \'ZN\'O\' surge arresters

Araújo, Marcel Ayres de 18 July 2013 (has links)
As tensões induzidas e sobretensões geradas por descarga atmosféricas diretas e indiretas são um dos principais causadores de desligamentos não programados em redes de transmissão e distribuição. Estes desligamentos comprometem o fornecimento de energia a milhares de consumidores, sobretudo em regiões com constantes variações climáticas e com características orográficas bastante diversificadas, como apresentado no território brasileiro. Desse modo, cada vez mais esses fenômenos são estudados a fim de desenvolverem-se procedimentos para proteção contra distúrbios causados por descargas atmosféricas. Neste contexto, esta pesquisa contempla o estudo do estabelecimento das descargas atmosféricas indiretas e das tensões por elas induzidas em linhas de distribuição, assim como o assentamento das mesmas nestas redes de energia. Não obstante, utilizando-se um software capaz de representar transitórios eletromagnéticos são modelados e implementados um alimentador teste de distribuição e um sistema para estimação de tensões induzidas no domínio do tempo baseado no modelo de Sune Rusck. Também são modelados e implementados para-raios de óxido de zinco, de forma a representar suas características dinâmicas, para proteger a linha sob apreciação dos distúrbios provocados pelas tensões induzidas. A partir de uma análise comparativa entre a operação do sistema de distribuição em regime permanente e frente aos desdobramentos promovidos pelas tensões induzidas, é determinada a melhor configuração, localização e quantificação dos para-raios a serem instalados para proteção do sistema teste. Por meio da avaliação dos resultados das simulações computacionais observa-se a robustez da subestação e quais os ramos e cargas mais suscetíveis a perturbações frente às tensões induzidas, bem como a maior proteção oferecida pelos para-raios aos elementos conectados próximos aos seus nós de alocação. / The induced voltages and overvoltages generated by direct and indirect lightning are a major cause of not programmed shutdowns in transmission and distribution networks. These shutdowns compromise the power supply of thousands of consumers, especially in regions with frequent climatic variations and quite diverse orographic characteristics, as occurred on Brazilian soil. Thus, these phenomena are more and more studied in order to develop procedures for protection against disturbances caused by lightning. In this context, this research focuses on the study of the establishment of indirect lightning and the voltage induced by them on distribution lines, as well as their settlement on energy networks. However, using a software able to represent electromagnetic transients, a distribution test feeder and a system for estimating induced voltages in the time domain based on the Sune Rusck model are modeled and implemented. In addition, metal oxide surge arresters are modeled and implemented to represent its dynamic characteristics, in order to protect the line under consideration of disturbances caused by induced voltages. From a comparative analysis between the operation of the distribution system in steady state and facing the developments promoted by induced voltages, it is determined the best configuration, as well as the location and quantification of the surge arrester to be installed to protect the test system. Through evaluation of the results of computer simulations, it is observed the robustness of the substation and which branches and loads are more susceptible to the disturbances facing the induced voltages, and the greater protection offered by the surge arresters elements connected near to its nodes allocation.
14

Metodologia para o diagnóstico em tempo real de para-raios em sistemas de distribuição e transmissão de energia elétrica / Methodology for Real Time Diagnostic of Surge Arresters in Electric Energy Distribution and Transmission Systems

Alves, Marcos Eduardo Guerra 08 November 2013 (has links)
Dada a importância dos para-raios para a proteção dos diversos equipamentos e instalações nos sistemas de distribuição e transmissão de energia elétrica contra danos provocados por sobretensões transitórias, quer sejam originadas por descargas atmosféricas, quer por estabelecimento e interrupção de cargas reativas (sobretensões de manobra), é apresentada uma nova metodologia de diagnóstico de seu estado. São apresentadas também as formas construtivas dos para-raios com tecnologias de carboneto de silício (SiC) e óxido de zinco (ZnO), as quais são associadas a modelos elétricos de representação completos e simplificados, de forma a facilitar a análise dos métodos de diagnóstico. Os métodos atualmente empregados para o diagnóstico dos para-raios, tanto fora de serviço quanto durante a operação, bem como suas potencialidades e pontos falhos são explanados, para os equipamentos de SiC e de ZnO. O novo método de diagnóstico proposto nesse trabalho é introduzido a seguir, baseado na monitoração da capacitância equivalente e resistência equivalente do para-raio, juntamente com simulações dos diversos tipos de defeitos passíveis de ocorrência em equipamentos de SiC e ZnO, verificando-se os parâmetros de medição afetados por cada um deles, de forma a estabelecer a efetividade do novo método de monitoração para a detecção dos defeitos. Também é apresentado um método para viabilização da monitoração em tempo real de capacitância e de resistência equivalentes, através da técnica de soma vetorial das correntes de fuga, atualmente já empregada para monitoração de buchas capacitivas de transformadores e outros equipamentos. Por fim, são apresentados os resultados esperados com o novo método de monitoração e as sugestões de novas etapas para trabalhos futuros. / Given the importance of surge arresters for the protection of several devices and installations in electric energy distribution and transmission systems from damages caused by transitory overvoltages, either originated from atmospheric discharges or by closing or opening of reactive loads (switching overvoltages), a new methodology for diagnosing their condition is presented. The constructive forms of surge arresters with silicon carbide (SiC) and zinc oxide (ZnO) technologies are presented, as well as their associated electric representation models, complete and simplified, so as to facilitate the analysis of diagnostic methods. Surge arrester diagnostic methods are presented, both off-line and on-line, together with their potentialities and weak points, for SiC and ZnO arresters. The new diagnostic method proposed in this work is introduced next, based on monitoring of the arrester equivalent capacitance and equivalent resistance, followed by simulations of the several possible defect types in SiC and ZnO devices. The measured parameters affected by each defect type are checked in order to establish the effectiveness of the new monitoring method for the detection of arrester problems. A method for making the monitoring of equivalent capacitance and resistance is also presented, by using the vector sum of leakage currents technique, largely used for monitoring of capacitive bushings in power transformers and other equipment. Finally, the results expected with the new monitoring method and suggestions for future work are presented.
15

Estudo de metodologia para modelagem e simulação de tensões induzidas de origem atmosférica em linhas de distribuição protegidas por para-raios de \'ZN\'O\' / Study of methodology for modeling and simulation of induced voltages of atmospheric origin in distribution lines protected by \'ZN\'O\' surge arresters

Marcel Ayres de Araújo 18 July 2013 (has links)
As tensões induzidas e sobretensões geradas por descarga atmosféricas diretas e indiretas são um dos principais causadores de desligamentos não programados em redes de transmissão e distribuição. Estes desligamentos comprometem o fornecimento de energia a milhares de consumidores, sobretudo em regiões com constantes variações climáticas e com características orográficas bastante diversificadas, como apresentado no território brasileiro. Desse modo, cada vez mais esses fenômenos são estudados a fim de desenvolverem-se procedimentos para proteção contra distúrbios causados por descargas atmosféricas. Neste contexto, esta pesquisa contempla o estudo do estabelecimento das descargas atmosféricas indiretas e das tensões por elas induzidas em linhas de distribuição, assim como o assentamento das mesmas nestas redes de energia. Não obstante, utilizando-se um software capaz de representar transitórios eletromagnéticos são modelados e implementados um alimentador teste de distribuição e um sistema para estimação de tensões induzidas no domínio do tempo baseado no modelo de Sune Rusck. Também são modelados e implementados para-raios de óxido de zinco, de forma a representar suas características dinâmicas, para proteger a linha sob apreciação dos distúrbios provocados pelas tensões induzidas. A partir de uma análise comparativa entre a operação do sistema de distribuição em regime permanente e frente aos desdobramentos promovidos pelas tensões induzidas, é determinada a melhor configuração, localização e quantificação dos para-raios a serem instalados para proteção do sistema teste. Por meio da avaliação dos resultados das simulações computacionais observa-se a robustez da subestação e quais os ramos e cargas mais suscetíveis a perturbações frente às tensões induzidas, bem como a maior proteção oferecida pelos para-raios aos elementos conectados próximos aos seus nós de alocação. / The induced voltages and overvoltages generated by direct and indirect lightning are a major cause of not programmed shutdowns in transmission and distribution networks. These shutdowns compromise the power supply of thousands of consumers, especially in regions with frequent climatic variations and quite diverse orographic characteristics, as occurred on Brazilian soil. Thus, these phenomena are more and more studied in order to develop procedures for protection against disturbances caused by lightning. In this context, this research focuses on the study of the establishment of indirect lightning and the voltage induced by them on distribution lines, as well as their settlement on energy networks. However, using a software able to represent electromagnetic transients, a distribution test feeder and a system for estimating induced voltages in the time domain based on the Sune Rusck model are modeled and implemented. In addition, metal oxide surge arresters are modeled and implemented to represent its dynamic characteristics, in order to protect the line under consideration of disturbances caused by induced voltages. From a comparative analysis between the operation of the distribution system in steady state and facing the developments promoted by induced voltages, it is determined the best configuration, as well as the location and quantification of the surge arrester to be installed to protect the test system. Through evaluation of the results of computer simulations, it is observed the robustness of the substation and which branches and loads are more susceptible to the disturbances facing the induced voltages, and the greater protection offered by the surge arresters elements connected near to its nodes allocation.
16

Modelo elétrico de supressor de surto de ZnO com ampla faixa de operação.

BRITO, Valdemir da Silva. 06 June 2018 (has links)
Submitted by Maria Medeiros (maria.dilva1@ufcg.edu.br) on 2018-06-06T13:59:11Z No. of bitstreams: 1 VALDEMIR DA SILVA BRITO - TESE (PPGEE) 2016.pdf: 24283842 bytes, checksum: 359b3901fbb8d95187c4a580e505a74f (MD5) / Made available in DSpace on 2018-06-06T13:59:11Z (GMT). No. of bitstreams: 1 VALDEMIR DA SILVA BRITO - TESE (PPGEE) 2016.pdf: 24283842 bytes, checksum: 359b3901fbb8d95187c4a580e505a74f (MD5) Previous issue date: 2016-10-07 / Capes / Este trabalho propõe um modelo elétrico de supressor de surto de ZnO que o representa com exatidão nas três regiões de operação, em uma ampla faixa de frequência e amplitude. O Modelo Elétrico Proposto (MEP) foi validado a partir de um banco de dados, contendo resultados de medições de tensão e corrente. Este banco de dados é constituído por medições em doze varistores de ZnO de cinco fabricantes diferentes, com diferentes dimensões físicas e características elétricas. Nos ensaios, os varistores foram submetidos a diversos níveis de tensão na região de baixas correntes. Também foram aplicados aos varistores vários níveis de amplitude de impulsos de corrente de manobra (30/60 µs), descarga atmosférica (8/20 µs), alta corrente (4/10 µs) e impulsos de corrente com frentes de onda mais rápidas (1,5/26 µs e 3/6 µs), abordando as regiões altamente não linear e altas correntes. Adicionalmente, outros ensaios foram realizados com objetivo de verificar a presença do acoplamento indutivo e a influência do invólucro do supressor de surto na medição da tensão residual. A partir do banco de dados, foram realizadas simulações com o MEP, e com os modelos Convencional e IEEE, já consolidados no meio científico. Os resultados dos modelos foram comparados entre si, e com os resultados de medição. O MEP apresentou melhores resultados em praticamente todos os casos, nas três regiões de operação. O MEP também foi avaliado em estudos reais de energização de linha de transmissão, rejeição de carga e coordenação de isolamento. Os resultados de simulação dos estudos apresentaram níveis de amplitude condizentes com o esperado, e não apresentaram oscilações numéricas ou instabilidade. Os parâmetros do MEP são de fácil determinação, e todas as informações necessárias estão contidas nos datasheets dos fabricantes. / This work proposes an electric model of ZnO surge arresters that represents accurately the ZnO surge arresters in a wide range of frequencies and amplitudes. The Proposed Electric Model (PEM) was validated from a database, containing results of voltage and current measurements. This database are based in twelve ZnO varistors of five different manufacturers, with different physical dimensions and electrical characteristics. In the lab tests, the varistors were submitted to different voltage levels in the low current region. There were also applied to the varistors multilevel amplitude of switching current impulses (30/60 µs), lightning current impulses (8/20 µs), high current impulses (4/10 µs) and current impulses with very fast front time (1.5/26 µs and 3/6 µs), addressing the highly nonlinear and high current regions. In addition, other lab tests were conducted in order to verify the presence of inductive coupling and the infuence of the surge arrester housing in the residual voltage measuring. From the database, simulations were performed with the PEM, with the Conventional and IEEE models which are already consolidated in the scientific community. The results of the models were compared among themselves, and with the measurement results. The PEM presented best results in practically all cases, in all three operating regions. The PEM was also evaluated in real studies of transmission line energization, load shedding and insulation coordination. The simulation results of the studies presented amplitude levels as expected and did not presented numerical oscillations or instability. The PEM parameters are easily determined, besides that all necessary information is contained in the manufacturers datasheet.
17

Implementação computacional para avaliar os níveis de sobretensões atmosféricas induzidas em linhas de distribuição

Thomazella, Rogério [UNESP] 03 December 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-12-03Bitstream added on 2014-06-13T18:52:41Z : No. of bitstreams: 1 thomazella_r_me_bauru_prot.pdf: 788309 bytes, checksum: a630d7e9326542247d07d560a3da2dd5 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente trabalho visa o desenvolvimento de uma ferramenta computacional confiável na análise e estimação dos níveis de tensões induzidas em linhas de distribuição. Neste contexto, utilizam-se ferramentas computacionais consolidadas, como o ATP (Alternative Transients Program), que combinado a um software desenvolvido em Visual Basic, permitem quantificar e avaliar o nível de sobretensões nas linhas de distribuição. Por meio de modificações nas técnicas clássicas de modelagem das descargas atmosféricas, foi possível a construção de um software em Visual Basic capaz de quantificar os valores das tensões induzidas em linhas de distribuição finitas. A avaliação dos níveis de sobretensões induzidas nas mesmas foi implementada pela associação deste software a um programa de simulação (ATP), a fim de se obter resultados fidedignos deste transitório. Tais resultados foram utilizados para se avaliar o desempenho das... / The present work aims at the development of a trustworthy computacional tool in the analysis and estimate of the levels of induced overvoltage in distribution network. In this context, consolidated computacional tools are used, as ATP (Alternative Transients Program), that combined with a software developed in Visual Basic (beginner's all-purpose symbolic instruction code), they allow to quantify and to evaluate the level of overvoltage in the distribution network. By the means of modifications in the classic techniques of modeling of the atmospheric discharges, the construction of a software in Visual Basic was possible to quantify the values of the induced overvoltage in a finite... (Complete abstract click electronic access below)
18

Avaliação da contaminação provocada por para-raios radioativos de amerício-241 descartados em lixões

MARUMO, JULIO T. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:31Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
19

Metodologia para o diagnóstico em tempo real de para-raios em sistemas de distribuição e transmissão de energia elétrica / Methodology for Real Time Diagnostic of Surge Arresters in Electric Energy Distribution and Transmission Systems

Marcos Eduardo Guerra Alves 08 November 2013 (has links)
Dada a importância dos para-raios para a proteção dos diversos equipamentos e instalações nos sistemas de distribuição e transmissão de energia elétrica contra danos provocados por sobretensões transitórias, quer sejam originadas por descargas atmosféricas, quer por estabelecimento e interrupção de cargas reativas (sobretensões de manobra), é apresentada uma nova metodologia de diagnóstico de seu estado. São apresentadas também as formas construtivas dos para-raios com tecnologias de carboneto de silício (SiC) e óxido de zinco (ZnO), as quais são associadas a modelos elétricos de representação completos e simplificados, de forma a facilitar a análise dos métodos de diagnóstico. Os métodos atualmente empregados para o diagnóstico dos para-raios, tanto fora de serviço quanto durante a operação, bem como suas potencialidades e pontos falhos são explanados, para os equipamentos de SiC e de ZnO. O novo método de diagnóstico proposto nesse trabalho é introduzido a seguir, baseado na monitoração da capacitância equivalente e resistência equivalente do para-raio, juntamente com simulações dos diversos tipos de defeitos passíveis de ocorrência em equipamentos de SiC e ZnO, verificando-se os parâmetros de medição afetados por cada um deles, de forma a estabelecer a efetividade do novo método de monitoração para a detecção dos defeitos. Também é apresentado um método para viabilização da monitoração em tempo real de capacitância e de resistência equivalentes, através da técnica de soma vetorial das correntes de fuga, atualmente já empregada para monitoração de buchas capacitivas de transformadores e outros equipamentos. Por fim, são apresentados os resultados esperados com o novo método de monitoração e as sugestões de novas etapas para trabalhos futuros. / Given the importance of surge arresters for the protection of several devices and installations in electric energy distribution and transmission systems from damages caused by transitory overvoltages, either originated from atmospheric discharges or by closing or opening of reactive loads (switching overvoltages), a new methodology for diagnosing their condition is presented. The constructive forms of surge arresters with silicon carbide (SiC) and zinc oxide (ZnO) technologies are presented, as well as their associated electric representation models, complete and simplified, so as to facilitate the analysis of diagnostic methods. Surge arrester diagnostic methods are presented, both off-line and on-line, together with their potentialities and weak points, for SiC and ZnO arresters. The new diagnostic method proposed in this work is introduced next, based on monitoring of the arrester equivalent capacitance and equivalent resistance, followed by simulations of the several possible defect types in SiC and ZnO devices. The measured parameters affected by each defect type are checked in order to establish the effectiveness of the new monitoring method for the detection of arrester problems. A method for making the monitoring of equivalent capacitance and resistance is also presented, by using the vector sum of leakage currents technique, largely used for monitoring of capacitive bushings in power transformers and other equipment. Finally, the results expected with the new monitoring method and suggestions for future work are presented.
20

Avaliação da contaminação provocada por para-raios radioativos de amerício-241 descartados em lixões

MARUMO, JULIO T. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:31Z (GMT). No. of bitstreams: 0 / Os pára-raios radioativos foram fabricados no Brasil até 1989, quando a Comissão Nacional de Energia Nuclear (CNEN) suspendeu a concessão de uso de material radioativo nesses artefatos. Desde então, o pára-raios radioativo tem sido substituído por outro, do tipo Franklin, e recolhido como rejeito radioativo. Entretanto, apenas 23 % do total fabricado no país foram entregues à CNEN. Esta situação é preocupante, pois a chance, desses artefatos serem descartados como resíduo comum e chegarem a lixões, é grande, uma vez que, segundo dados do Instituto Brasileiro de Geografia e Estatística (IBGE), em 2000, 63,6 % dos municípios brasileiros dispunham o resíduo nesses locais. Além disso, o amerício, o radionuclídeo mais empregado, é classificado como sendo um elemento de alta toxicidade, quando ingerido ou inalado. No presente trabalho, foram realizados experimentos de migração de Am-241 em lisímetros, com o objetivo de se avaliar o risco de contaminação provocada por pára-raios radioativos descartados como resíduo comum. Fontes radioativas removidas de pára-raios foram inseridas em lisímetros preenchidos com resíduo orgânico, coletado no restaurante do Instituto de Pesquisas Energéticas e Nucleares, IPEN-CNEN/SP, e chorume gerado foi periodicamente analisado para determinar suas características como pH, potencial redox, teor de sólidos e a concentração do material radioativo. O crescimento microbiano também foi avaliado, pelo método de contagem direta do número de unidades formadoras de colônia. A estimativa de risco foi baseada no cálculo de dose para membros do público, sendo a ingestão de água a via mais provável de exposição. O valor obtido foi cerca de 1000 vezes inferior ao limite de dose anual estabelecido, pela Comissão Internacional de Proteção Radiológica (ICRP), demonstrando que o risco de contaminação provocado pelo descarte de pára-raios em lixões é baixo. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP

Page generated in 0.1213 seconds