Spelling suggestions: "subject:"tereza""
11 |
Influencia da escovação mecanica na rugosidade de superficie de materiais restauradores esteticosFrancisco, Mauro Uriarte 11 October 2000 (has links)
Orientador: Lourenço Correr Sobrinho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T12:03:18Z (GMT). No. of bitstreams: 1
Francisco_MauroUriarte_M.pdf: 3424806 bytes, checksum: 47006e8306842cdbe7b0a44693ea0974 (MD5)
Previous issue date: 2000 / Resumo: O propósito deste estudo foi investigar a influência da escovação mecânica na rugosidade de superfície dos materiais restauradores Artglass (Kulzer), Targis (Ivoclar) e Sculpture (Jeneric/Pentron). Oito amostras com 7mm de diâmetro por 2,5 mm de espessura foram confeccionadas para cada material. O Artglass foi polimerizado no forno Uni-XS por 180 segundos, o Targis foi polimerizado no aparelho Targis Power por 25 minutos e o Scuípture foi polimerizado por 10 minutos com o aparelho Cure Lite. Todas as amostras foram armazenadas em água destilada a 37° C, por 24 horas. Em seguida quatro amostras de cada material receberam acabamento e polimento e outras quatro serviram como controle. A rugosidade foi verificada com o aparelho Surf-corder (SE 1700), antes e após as amostras serem submetidas a 30.000 ciclos numa máquina de escovação Equilabor, usando escova dental (Kolynos) e dentifrício (Sorriso). Foram feitas três leituras em cada amostra, totalizando 72 leituras. Os resultados foram submetidos à análise de variância e ao teste de Tukey (5%) e indicaram que: 1- Para as amostras sem polimento, antes da escovação, a rugosidade do Targis (0,535 um) foi superior em relação ao Sculpture (0,190 um). Nenhuma diferença estatística foi observada quando o Targis foi comparado com o Artglass (0,330 um) e o Artglass com o Sculpture. Após a escovação, nenhuma diferença estatística foi observada entre o Targis (0,945 um), Artglass (0,597 um) e Sculpture (0,810 um); 2 - Para as amostras com polimento não houve diferença estatística entre os materiais Targis, Artglass e Sculpture, antes (0,627 um; 0,551 um; 0,535 um) e após a escovação (0,283 um; 0,344 um; 0,122 um); e, 3 -Os resultados indicaram que a escovação promoveu aumento na rugosidade de superfície nas amostras sem polimento e redução nas amostras com polimento / Abstract: The purpose of this study was to investigate the influence of mechanic brushing on surface roughness restorative materials of Artglass (Kulzer), Targis (Ivoclar) and Sculpture (Jeneric/Pentron). Eight samples with 7 mm in diameter and 2.5 mm in thickness were made for each material. The Artglass was cured in an Unix-XR oven for 180 seconds, the Targis was cured in a curing unit Targis Power for 25 minutes and Sculpture was cured for 10 minutes with Cure Lite unit. All samples were stored in distilled water at 37° C, for 24 hours. After four samples of each material received finishing and polishing treatment and four (control) without treatment. Roughness was verified using Surf-corder (SE 1700), before and after the specimens had been submitted to 30,000 cycling in an Equilabor brushing machine, using toothbrush (Kolynos) and toothpaste (Sorriso). Afterwards, the rougness were verified.The results were submitted to variance analysis and Tukey's test (5%) and indicated that: 1 - For the samples without polishing before toothbrushing the roughness for Targis (0.535 urn) was significantly stronger than Sculpture (0.190 |jm). No difference was found when Targis was compared with Artglass (0.330 urn) and when Artglass was compared with Sculpture. No difference was found after toothbrushing Targis (0.945 urn), Artglass (0.597 urn) and Sculpture (0.810 urn); 2 - For the samples with polishing , no difference was found among Targis, Artglass and Sculpture with polishing, before (0.627 urn; 0.551 urn; 0.535 urn) and after toothbrushing (0.283 urn; 0.344 urn; 0.122 urn). The results indicated that the mechanic brushing showed increased on surface roughness for the specimens without polishing and reduction for specimens with polishing / Mestrado / Materiais Dentarios / Mestre em Odontologia
|
12 |
Analise da rugosidade radicular apos instrumentação periodontal : estudo "in vitro"Martins, Eleonora de Oliveira Bandolin 26 July 2001 (has links)
Orientadores : Antonio Wilson Sallum, Enilson Antonio Sallum / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T23:28:26Z (GMT). No. of bitstreams: 1
Martins_EleonoradeOliveiraBandolin_D.pdf: 5329012 bytes, checksum: 0abd0bd9fc5363f22c6576baea267c8f (MD5)
Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar, in vitro, o grau de rugosidade radicular produzido pelos vários tipos de instrumentos utilizados durante o processo de instrumentação. Foram selecionados 110 dentes humanos extraídos. Estes dentes foram lavados em água corrente e acondicionados em recipientes com formol para serem manipulados todos ao mesmo tempo, por um único operador. Os dentes foram divididos aleatoriamente, em 11 grupos instrumentados com curetas Gracey; lima periodonta1; aparelho ultra-sônico; aparelho sônico; broca diamantada extra-fina, em caneta de alta e baixa-rotação; broca carbide multilaminada de 12 e 30 lâminas, em caneta de alta e baixa rotação; e grupo controle, sem instrumentação. Foram realizadas três leituras paralelas e três perpendiculares ao sentido de instrumentação, em cada amostra antes e depois da instrumentação, utilizando um aparelho rugosímetro. Os dados foram analisados estatisticamente pelos teste '1;" pareado e ANOV A. Os resultados mostraram que o uso de todos os instrumentos produziram aumento de rugosidade na superfície radicular. As pontas diamantada extra-finas utilizadas em alta-rotação produziram o menor aumento de rugosidade em relação ao grupo controle, seguido em ordem crescente de rugosidade pelos seguintes instrumentos: lima periodontal manual, cureta Gracey manual, broca de 30 lâminas em alta-rotação, ponta diamantada em baixa-rotação, broca de 12 lâminas em alta rotação, broca de 30 lâminas em baixa-rotação, broca de 12 lâminas em baixa-rotação, aparelho sônico e aparelho ultra-sônico. Foram também realizadas fotomicrografias das superfícies radiculares, após a instrumentação, em microscopia eletrônica de varredura, com aumento de 150 e 350 vezes, com fins ilustrativos / Abstract: The aim of this study was to evaluate the "in vitro" roughness degree generated by several instruments used for root planning. 110 extracted human teeth were selected. The teeth were washed and stored in formaline, to be manipulated all at the same time by only one person. Then, they were randomly divided into 11 groups and scaled with gracey hand curette, hand periodontal file, ultrasonic scaler, sonic sca1er, fine-grit-diamond bur with high and low-speed headpiece, 12 and 30-1amina bur with high and low-speed hand piece, and control group without instrumentation. Three parallel readings and 3 perpendicular readings were made on the instrumentation direction in the samples before and after instrumentation, with the use of a porfilometer. It was made a statistical data analysis through the doble "t" and ANOV A tests. The results showed that the fine-grit-diamond bur with high-speed hand piece had the lowest values of roughness increase in relation to the control group, followed by the groups: hand periodontal file; hand curette ; 30-lamina bur with high-speed hand piece; fine-grit-diamond bur with low-speed hand piece; 12-lamina bur with high-speed hand piece; 30-lamina bur with low-speed headpiece; 12-lamina bur with low-speed hand piece; sonic scaler and ultrasonic sca1er. Photomicrographs in scanning electron microscopy were taken for illustration, with 150 and 350 times of magnitude / Doutorado / Periodontia / Doutor em Clínica Odontológica
|
13 |
Uma contribuição ao estudo do processo de brunimentoVisque, Edvaldo Jose 05 November 1998 (has links)
Orientador: Olivio Novaski / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-24T11:35:31Z (GMT). No. of bitstreams: 1
Visque_EdvaldoJose_M.pdf: 5770574 bytes, checksum: 69299d8cb0fa1fec2be1452ab8e68556 (MD5)
Previous issue date: 1998 / Resumo: o processo de brunimento apresenta vários parâmetros de usinagem, cujas influências necessitam ser melhor conhecidas. Tais parâmetros compreendem a velocidade de corte, a pressão de contato e a velocidade de avanço, cujas influências se fazem sentir nos desvios macro e micro geométricos. O presente trabalho procurou analisam as influências da velocidade de corte e da pressão de contato, mantendo-se invariável a velocidade de avanço. Os experimentos foram divididos em três fases, quais sejam, a fase I, onde para um determinado valor de velocidade de corte, de velocidade de avanço e pressão de contato, utilizadas no processo normal de brunimento em análise, verificou-se o efeito da pré-usinagem. A fase II teve o propósito de verificar a influência da pressão de contato e a fase III objetivou a verificação da influência da velocidade de corte nos desvios. Os resultados mostram que, os desvios iniciais influenciam na porcentagem de correção dos mesmos. Da mesma maneira, a variação dos parâmetros estudados influenciam os resultados finais, sendo que, no presente caso, o aumento de tais parâmetros, atuou de maneira positiva / Abstract: The honing process presents several manufacturing parameters, whose influences need to be known better. Such parameters comprehend the cutting speed, the contact pressure and the infeed speed, whose influences appear in the macro and micro geometric deviations. The present study tried to analyze the influences of the cutting speed and the contact pressure,
keeping invariable the infeed speed. The experiments were divided in three to phases. Phase I, at a certain value of cutting speed, infeed speed and contact pressure, used in the normal process of honing analyzed, the pre-manufacturing effect was verified. The purpose of phase II was to verify the contact pressure influence and the phase III aimed the influence verification of the cutting speed at the deviations. The results showed that, the initial deviations influence this correction percentage in the same way, the variation of the studied parameters influence the final results and at the present case, the increase of such parameters acted in a positive way / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
|
14 |
Estudo in situ da rugosidade superficial de materiais hibridos de ionomero de vidro e resina composta submetidos a procedimentos de acabamento e polimento em função do tempo de permanencia na cavidade bucalMagalhães, Claudia Silami de 18 February 2000 (has links)
Orientador: Monica Campos Serra / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T21:21:31Z (GMT). No. of bitstreams: 1
Magalhaes_ClaudiaSilamide_D.pdf: 3601451 bytes, checksum: 40e0276b094752f2e3dcbfd845829566 (MD5)
Previous issue date: 2000 / Resumo: Este estudo teve como objetivo avaliar a rugosidade superficial de duas resinas modificadas por poliácidos e de um ionômero de vidro modificado por resina, submetidos a doistrattmrentos superfzciais de acabamento e polimento, em função do tempo, através de um modelo experimental in situo Vinte voluntários utilizaram, durante 28 dias cansecutivos, dispositivos acrz1icos intra-bucais, contendo corpos-de-proVQ confeccionados com um ionômero de vidro modificado por resina - Fuji 11 LC lmproved (aC) e com duas resinas compostas modificadas por poliácidos - Compoglass F (Vivadent) e Dyract AP (Dentsply I DeTrey). Os corpos-de-prova de dimens&s padronizadas (n=20) foram submetidos a acabamento e polimento com um sistema de discos de lixa a base de óxido de alumínio (Sof-Lex - 3M) ou com pontas de resina impregnadas com éxido de alumínio (Enhance - Dentsply). O grupo controle não recebeu acabamento e polimento, sendo apenas polimerizado contra a superjIcie de uma tira de matriz de poliéster. A cada voluntário foi fornecido o mesmo tipo de escova dental e dentifrício, além de instruç1Jes especifzcas sohre a utilização e higieniz(Jfâo do dispositivo intra-hucal. A rugosidade superficial dos materiais foi quantificada através da medida da rugosidade média (RcJ de nove segmentos lineares predeterminad()s de cada c()rpo-de-pr()va, imediatamente após os procedimentos de acabamento e polimento (/'.0) e após 1 (1'J), 2(1'2), 3(1'3), 7(1'7), 14(1'14), 21 (l'21) e 28 (l' 28) dias de permanência no meio bucal. Para cada tempo estudado foi realizada uma análise .de covariância, considerando T{) como covariáveL Foram aplicadas a decomposição de soma de quadrados e a diferença mínima significativa de Tukey para estudar as interações signifzcativas e as comparações pareadas, ao nível de signiflCância de 5%. Os resultados foram significativos para o efeito da interação Material x Tratamento, exceto no T 28. Inicialmente, para os materiais Compoglass F e Dyract AP, o tratamento com Sof-Lex promoveu maior lisura superficial que Enhance. Os tratamentos com Sof-Lex e Enhance não .cliferiram entre si e aumentaram a rugosidade superficial de Fuji II LC Improved em relação ao controle. A() término da perÍOlJ() de ()bservaÇÕ(), ()S materiais híbridas de ionômer() de vidr() e resina composta submetidos a acabamento e polimento apresentaram rugosidade superficial semelhante ao controle, a despeit() da técnica utilizada / Abstract: The purpose of this study was to evaluate the surface roughness of two polyacid modified composite resins and a resin modified glass-ionomer submitted to two finishing and polishing treatments, as afunction oftime, using an in situ experimental modelo A resin modified glassionomer Fuji II LC lmproved (GC) and two polyacid modified composite resins Compoglass F (Vivadent) and Dyract AP (Dentsply / DeTrey) were analyzed. Cylindrical specimens with standardized dimensions were made using each material (n= 20). Surface treatments were erformed with Sof-Lex (3M) discs or Enhance (Dentsply) tips. Specimens of control groups were not submitted to surface treatments. Twenty volunteers ware palatal appliances in which nine specimens were flXed, during 28 days. The same kind of toothbrush and dentifrice were supplied to each volunteer. Standardized brushing technique was directed to them in order to clean the appliances up. Average surface roughness (Ra) was measured with a roughness tester (Surfcorder SE 1700) immediatelyafter the treatment (1'0) and after 1 (1'1), 2 (1'2),3(1'3), 7 (1'7J, 14 (1'14), 21 (1'21), 28 (1'28) days, under oral conditions. Nine readingsfor each specimen were averaged to give a single value. Data were submitted to Analysis of ovariance considering To values the covariate. Sums of squares decompositions followed by Tukey's Least-significant difference were used to study significative interactions and pairwise comparisons, at 5% significance levei. There was statistically significant effect of interaction Material X Treatment at each time period, excepted T28. lnitially, specimens of materiais Compoglass F and Dyract AP treated with Sof-Lex were smoother than which were treated with Enhance. There was not statistically significant difference between treatments with SofLex and Enhance for Fuji 11 LC lmproved, but both increased its roughness, comparing to controlo After the exposed time to the oral conditions, it was possible to conclude that glassionomer composite resin hybrid materiais finished and polished surfaces presented roughness that was similar to untreated ones, regardless of the polishing method / Doutorado / Dentística / Doutor em Clínica Odontológica
|
15 |
Avaliação da rugosidade radicular produzida por instrumentos sonicos, ultrasonicos, manuais e rotatorios : estudo "in vitro"Martins, Eleonora de Oliveira Bandolin 22 November 1999 (has links)
Orientadores: Antonio Wilson Sallum, Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T20:17:36Z (GMT). No. of bitstreams: 1
Martins_EleonoradeOliveiraBandolin_M.pdf: 7956484 bytes, checksum: f7f49506511d11e364f455a2fe8cf344 (MD5)
Previous issue date: 1999 / Resumo: O objetivo deste trabalho é avaliar, in vitro, o grau de rugosidade radicular deixado pelos vários tipos de instrumentos utilizados durante o processo de instrumentação radicular. Foram selecionados 90 dentes unirradiculares, extraídos de pacientes que manifestaram periodontite avançada.. Em seguida, eles foram divididos aleatoriamente em 9 grupos experimentais (dez dentes por grupo), instrumentados com: grupo 1 - curetas Gracey; grupo 2 - aparelho sônico; grupo 3 - aparelho ultrasônico; grupo 4 - ponta diamantada extrafina, em caneta de alta-rotação; grupo 5 - ponta diamantada extrafina, em caneta de baixa-rotação; grupo 6 - broca carbide multilaminada de 12 lâminas, em caneta de alta-rotação; grupo 7 - broca carbide multilaminada de 12 lâminas, em caneta de baixa rotação; grupo 8 - broca carbide multilaminada de 30 lâminas, em caneta de alta-rotação; e, grupo 9 - broca carbide multilaminada de 30 lâminas, em caneta de baixa-rotação. Em seguida, foram confeccionadas amostras de cada raiz, as quais foram submetidas à análise rugosimétrica, obtendo-se a "porcentagem de redução de rugosidade por grupo" ( GR ). Estes dados foram submetidos à anális~ estatística. Foram também realizadas fotomicrografias em estereomicroscópio triocular e microscópio eletrônico de varredura para ilustrar a topografia da superficie radicular. Os resultados mostraram que as rugosidades foram diminuídas significantemente após a instrumentação em todos os grupos (45,16%). As brocas de 12 lâminas (67,75%) e a de 30 lâminas (65,02%) em alta-rotação mostraram valores maiores de porcentagem de redução de rugosidade e não diferiram estatisticamente entre si. Os grupos de ponta diamantada extra-fma em baixa-rotação (49,86%) e curetas (48,74%) não diferiram estatisticamente entre si, mas mostraram valores estatisticamente menores de porcentagem de ,redução de rugosidade em relação aos grupos seis e oito. Os grupos de diamantadas extra-fina em alta-rotação (40,90%) e 12 lâminas em baixa-rotação (39%) não diferiram estatisticamente entre si, mas mostraram valores estatisticamente menores de porcentagem de redução de rugosidade em relação ao grupos cinco e um. Os grupos de 30 lâminas em baixa-rotação (34,61%) e aparelho ultrasônico (33,33%) não diferiram estatisticamente entre si, mas mostraram valores estatisticamente menores porcentagem de redução de rugosidade radicular em relação aos grupos quatro e sete. O grupo de aparelho sônico (27,27%) mostrou o menor valor de porcentagem de redução de rugosidade, diferindo estatisticamente de todos os grupo / Abstract: The aim of this study was to evaluate in vitro the roughness degree generated for several instruments used for root planing. It were seleeted 90 teeth extracted from patients that had advaneed periodontal disease. Then, they were randomly divided into nine groups (ten teeth per group), sealed with several instruments: group 1: hand eurette; group 2: sonie sealer; group 3: ultrasonie sealer; group 4: fine grit diamond bur and high-speed handpieee; group 5: fine grit diamond bur and low-speed handpieee; group 6: 12 lamina bur and high-speed handpieee; group 7: 12 lamina bur and low-speed handpieee; group 8: 30 lamina bur and high-speed handpieee; group 9: 30 lamina bur and low-speed handpieee. After, it was made specimens from the roots that was taking step in the perfilometer, taking the "degree of roughness of the root" (Gr). It was take photomierographs in optieal mieroseopy and seanning eleetron mieroseopy to illustrate the roots surfaees. It was made a statistieal data analysis. The results showed that in alI groups the percent roughness deereased after instrumentation (45,16%). The 12 lamina (67,75%) and 30 lamina (65,02%) bur with high-speed showed the hig!1est values ofredueing ofroughness and didn't show signifieant differenee eaeh others. The fine grit diamond bur with 10w-speed handpieee (49,86%) and euretts (48,74%) groups didn't show signifieanee differenee eaeh other, but showed lower values than the six and eight groups. The fine grit diamond bur with high-speed handpieee(40,90%) and 12 lamina bur with low-speed handpieee (39%) didn't show differenee eaeh other, but showed values signifieant lower than the tive and one groups. The 30 lamina bur with low-speed handpieee (34,61 %) and ultrasonie (33,33%) didn't show signifieant differenee eaeh other, but showed signifieant lower values than the four and seven groups. The sonie sealer (27,27%) showed the signifieant lowest value of redueing of rougeess / Mestrado / Periodontia / Mestre em Clínica Odontológica
|
16 |
Estudo da modificação superficial de fibras de carbono por meio de tratamentos a plasma para o aumento da adesão na interface de compósitos fibra de carbono/PPS /Santos, Alberto Lima. January 2015 (has links)
Orientador: Leide Lili Gongalves da Silva Kostov / Coorientador: Edson Cocchieri Botelho / Coorientador: Mario Ueda / Banca: Rogério Pinto Mota / Banca: Michelle Leali Costa / Banca: Mirabel Cerqueira Rezende / Banca: Carina Barros Mello / Resumo: Este trabalho refere-se ao processamento de compósitos termoplásticos obtidos a partir de fibras de carbono tratadas por meio de técnicas assistidas por plasma. Os tratamentos empregados foram Descarga Elétrica com Barreira Dielétrica (DBD), que é realizada em pressão atmosférica, envolvendo menores energias e a Implantação Iônica por Imersão em Plasma (3IP), que é realizada em baixa pressão, envolvendo energias mais elevadas. Após o tratamento, foi realizada a caracterização das amostras tratadas e não tratadas para efeito de comparação e também para verificar qual tratamento foi mais eficaz na obtenção de melhores propriedades físico-químicas da fibra para a obtenção dos compósitos termoplásticos, os quais foram produzidos pelo método de moldagem por compressão a quente. Várias técnicas de caracterização foram empregadas, tais como: microscopia eletrônica de varredura, microscopia de força atômica, espectroscopia Raman, espectroscopia de fotoelétrons excitados por raios X, difração de raios-X, e alguns ensaios mecânicos do compósito, tais como: testes de cisalhamento interlaminar e análise dinâmico-mecânica. Após a análise dos resultados, verificou-se que os tratamentos DBD e 3IP são ferramentas eficazes para melhorar a adesão da interface fibra/matriz polimérica, devido ao aumento da rugosidade da fibra e da introdução de grupos polares em sua superfície. Adicionalmente, houve um aumento da resistência ao cisalhamento dos compósitos obtidos a partir de fibras tratadas por ambos os processos a plasma (DBD e 3IP) / Abstract: In this it has been carried out the processing of thermoplastic composites obtained from carbon fibers (CF) treated by plasma assisted techniques. The employed treatments were Dielectric Barrier Discharge (DBD) that is performed in atmospheric pressure, involving low energy and Plasma Immersion Ion Implantation (PIII), which is held in low pressure regime, consisting of higher energies. After these treatments, both treated and untreated samples, were characterized. A comparison of the results was carried out to determine which treatment is most effective to achieve better physico-chemical properties on the fibers to obtain thermoplastic composites, which were produced by hot compression molding. Several characterization techniques were employed, such as scanning electron microscopy (SEM), atomic force microscopy (AFM), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), X-ray diffraction, and some mechanical tests of the composites, such as interlaminar shear strength (ILSS) and dynamic mechanical analysis (DMA). After analyzing the results, it was verified that the DBD and PIII treatments are effective tools for improving the adhesion of the carbon fiber/polymeric matrix interface, due to the CF roughness increasing and the introduction of polar groups on the carbon fiber surface. Additionally, it was noticed an increase of composites shear strength that were produced with treated carbon fibers (DBD and PIII) / Doutor
|
17 |
Análise comparativa do uso de ferramentas de metal duro sem revestimento e revestidas com diboreto de titânio na usinagem da madeira /Celestino, Valter Roberto de Brito. January 2015 (has links)
Orientador: Manoel Cleber de Sampaio Alves / Banca: Marcos Tadeu Tiburcio Gonçalves / Banca: Ivaldo de Domenico Valarelli / Resumo: A utilização de processos de usinagem para dar forma e acabamento é madeira tem sido ampliada muito nos últimos anos, levada pela necessidade de peças que contenham um melhor acabamento superficial atrelado à boa produtividade que é conseguida pelo aperfeiçoamento contínuo de equipamentos e de ferramentas para processar a madeira. Este trabalho utilizou um sistema experimental de torneamento com um novo cabeçote porta-ferramenta, contendo sensores de potência, vibração e emissão acústica acoplados em um torno EMCO Compact 5, muito comum para procedimentos didáticos, adaptados para o processamento de madeiras de pinus spp, a fim de demonstrar pela utilização da instrumentaçãodo processo, pode influenciar positivamente na análise de algum parâmetros como a rugosidade média (Ra) e rugosidade total (Rt), além dos valores de emissão acústica, potência de corte e vibração. A coleta dos dados se mostrou eficiente e precisa para os parâmetros principais de velocidade de avanço em 40 mm/min, 70 mm/min e 100 mm/min e variações de profundidade de corte em 0,5mm; 1,0 mm; e 1,5 mm; com velocidade de corte constante, e o uso de duas ferramentas de metal duro, uma constituída por metal duro polido e sem revestimento e outra ferramenta revestida com diaboreto de titânio. Entre os principais resultados obtidos, nota-se que a ferramenta com revestimento não influenciou na rugosidade média, e proporcionou menor rugosidade total e potência consumida, mas apresentou maiores valores para a vibração e emissão acústica captada durante os experimentos. Com relação ao tipo de madeira, os dados aquisitados estão coerentes, exceto pelos valores de potência consumida, que podem estar ligados a características próprias das peças de madeira usadas / Abstract: The use of machining processes to shape and finish will wood has been greatly expanded in recent years, driven by the need for parts that contain a better surface finish tied will good productivity is achieved by continuous improvement of equipment and tools to process wood. This study used an experimental turning system with a new tool holder head, containing power sensors, vibration and acoustic emission engaged in a lathe EMCO Compact 5, very common for teaching procedures, adapted for the processing of wood pinus spp and eucalyptus spp, to demonstrate the use of the process instrumentation, can positively influence the analysis of some parameters such as the average roughness (Ra), total toughness (Rt), plus the acoustic emission values, cutting performance and vibration. Data collection was efficient and accurate for the main parameters of forward speeds at 40 mm/min, 70 mm/min and 100 mm/min and variations of the cutting depth of 0.5 mm; 1.0 mm; and 1.5 mm; with constant surface speed, and the use of two carbide tools, consisting of a polished carbide and uncoated and coated other tool with titanium diboride. The main results obtained, it is noted that the coating tool did not influence the average roughness, and provided lower total roughness and consumed power, but showed higher values for vibration and acoustic emission captured during the experiments. Regarding the type of wood, obtained data are consistent, except for the consumed power values, which may be linked to characteristics of used pieces of wood / Mestre
|
18 |
Caracterização mecânica e microestrutural da y-tzp sinterizada por micro-ondas e degradada em meio bucal /Barchetta, Nayara Fernanda. January 2019 (has links)
Orientador: Guilherme de Siqueira Ferreira Anzaloni Saavedra / Coorientadora: Anelyse Arata / Banca: Dolores Ribeiro Ricci Lazar / Banca: João Paulo Barros Machado / Banca: Renata Marques de Melo Marinho / Banca: Estevão Tomomitsu Kimpara / Resumo: Neste estudo avaliou-se por caracterização mecânica e microestrutural, a degradação em meio bucal e in vitro da cerâmica Y-TZP sinterizada por energia de micro-ondas em comparação ao método convencional. Foram confeccionados noventa e seis discos por CAD-CAM (ISO 6872), sinterizados de modo convencional (C) 1530°C/120 minutos e por energia de micro-ondas (M) 1450°C/15 minutos. E submetidos à degradação hidrotérmica em reator pressurizado (E) (1,5h/150°C/3 bar) e à degradação in situ (B) (240 horas em meio bucal), formando-se 8 grupos (n = 12): M, C, ME, CE, MB, CB, MEB e CEB. Foram realizadas análises de contração volumétrica, difração de raios-X (DRX), rugosidade superficial (Ra e Rz), ângulo de contato, microscopia eletrônica de varredura (MEV), quantificação do biofilme por UFC/mL e análise de resistência mecânica por flexão biaxial. Os resultados obtidos foram analisados estatisticamente por t-Student, Anova dois e três fatores, e teste de Tukey (5%). Por DRX observou-se transformação de fase tetragonal para monoclínica (t-m) nos grupos envelhecidos, exceto para o grupo MB. Não foram observadas diferenças significantes na contração volumétrica (p=0,274), na rugosidade Ra (p=0,137) e Rz (p=0,187), assim como nos valores de ângulo de contato entre os métodos de sinterização (p=0,669). Por MEV observou-se a presença de formação de biofilme inicial e na contagem de Unidades Formadoras de Colônias (UFC/mL) foi maior quando os espécimes foram previamente envelhecidos in vitro (... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this study ir was evaluated the effect of in situ low temperature degradation of yttrium oxide stabilized tetragonal zirconia polycrystal (Y-TZP) ceramics sintered by microwave energy in comparison to the conventional method. Ninety-six discs milled by CAD/CAM (ISO 6872) were divided in: conventionally sintered (C) at 1530 ° C / 120 minutes and microwave energy (M) 1450°C / 15 minutes. Specimens were submitted to hydrothermal degradation in a pressurized reactor (E) (1.5h / 150°C / 3 bar) and in situ degradation (B) (240 hours in the buccal medium), forming eight groups (n=12): M, C, ME, CE, MB, CB, MEB and CEB. Specimens were evaluated through analysis of volumetric contraction, X-ray diffraction (XRD), surface roughness (Ra and Rz), contact angle, scanning electron microscopy (SEM), biofilm quantification by CFU / mL and biaxial flexural strength. Results were statistically analyzed through t-Student, two, three-way Anova and Tukey tests (5%). By XRD, tetragonal to monoclinic phase transformation (t-m) was observed in the aged groups, except for the MB group. No significant differences were observed in the volumetric contraction (p = 0.274), Ra roughness (p = 0.137) and Rz (p = 0.187), as well as contact angle values between sintering methods (p = 0.669). SEM images showed that the initial biofilm formation was observed after 8 hours in situ, an increase of CFU / mL occurred when the specimens were previously aged in vitro (p = 0.001). Regarding biaxial flexural strength... (Complete abstract click electronic access below) / Doutor
|
19 |
Aplicação de fluido de corte em quantidades reduzidas para usinagem do aço SAE 52100 no processo de retificação centerless de passagemGonçalves Neto, Luiz Maurício [UNESP] 12 September 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:46Z (GMT). No. of bitstreams: 0
Previous issue date: 2013-09-12Bitstream added on 2014-06-13T20:46:54Z : No. of bitstreams: 1
goncalvesneto_lm_dr_bauru_parcial.pdf: 467034 bytes, checksum: 2bcecb1f926016c9fb67986aaa61bd48 (MD5) Bitstreams deleted on 2015-06-25T13:01:24Z: goncalvesneto_lm_dr_bauru_parcial.pdf,. Added 1 bitstream(s) on 2015-06-25T13:03:35Z : No. of bitstreams: 1
000722680_20161010.pdf: 395351 bytes, checksum: 75e21b3a6eaf2785643e33fc7caec54e (MD5) Bitstreams deleted on 2016-10-10T12:18:28Z: 000722680_20161010.pdf,. Added 1 bitstream(s) on 2016-10-10T12:19:01Z : No. of bitstreams: 1
000722680.pdf: 3376023 bytes, checksum: 9612a64fd3199196c204263b3922817d (MD5) / A presente tese propõe dar uma contribuição para o estudo de aplicação de fluido de corte no processo de retificação centerless de passagem, comparando os efeitos causados em termos de integridade da peça retificada entre a técnica convencional e a técnica aprimorada desenvolvida para o uso racional dos fluidos de corte. As condições testadas foram as seguintes: retificação centerless de passagem utilizando rebolo de corte convencional (C120TB24), três condições de lubrirefrigeração, bocal convencional (BC), bocal multitubular utilizando emulsão (BME) e bocal multitubular utilizando simultaneamente emulsão e ar comprimido (BMEA). Vazão do ar comprimido 170 L/min, vazões da emulsão: 10 L/min, 20 L/min, 30 L/min e 40 L/min e remoção de material de 0,03 mm e 0,10 mm. As variáveis de saída estudadas foram a rugosidade da superfície retificada, o desvio de circularidade e a tensão residual. Além disso, foram realizadas análise metalográfica, análise por partículas magnéticas e ataque químico com ácido nítrico da superfície retificada a fim de identificar a ocorrência de danos térmicos. Em relação às três técnicas de aplicação de fluido de corte utilizados (BC, BME e BMEA) no processo de retificação centerless passagem, em geral, observou-se um melhor desempenho com a utilização do novo conceito de bocal multitubular desenvolvido. As melhores condições de retificação foram observadas utilizando o BMEA para as vazões de 30 L/min e 40 L/min e com o BME para vazão de 30 L/min, removendo 0,03 mm de material. Para essas condições o processo foi capaz de garantir a integridade das peças, pois não apresentam danos térmicos às superfícies retificadas e mantiveram-se os valores dos desvios de circularidade e rugosidade superficial recomendados para o processo de retificação. O método convencional (BC)... / This work aims to contribute to the study and application of cutting fluid in the process of through-feed centerless grinding, comparing the effects in terms of workpiece integrity between the conventional technique and the improved technique developed for the rational use of cutting fluids. The test conditions were as follows: through-feed centerless grinding using silicon carbide resinoid grinding wheel (C120 TB24), three conditions of lubri-refrigeration, conventional nozzle (BC), multi-tube nozzle with emulsion (BME) and multitube nozzle with emulsion and compressed air simultaneously (BMEA). Compressed air flow rate 170 L/min, emulsion flow rate: 10 L/min, 20 L/min, 30 L/min, 40 L / min and material removal from 0,03 mm to 0,10mm. The output variables studied were the roughness of the ground surface, roundness deviation and residual stress. Additionally, metallographic analysis were performed as well as chemical attack with nitric acid on the ground surface in oder to identify the occurrence of thermal damage. Regarding the three techniques of cutting fluid application (BC, BME and BMEA0 in the process of through-feed centerless grinding, in general we observed a better performance when using the new concept of developed multi-tube nozzle. The best grinding conditions were observed using BMEA for the flow ratesn of 30 L/min and 40 L/min and with BME for the rate of 30 L / min, removing 0,03 mm of material. Fo these conditions the process was able to ensure workpiece integrity, since there were not thermal damage to the surface that were ground and the deviation values of roundness and surface roughness recommended for the grinding process were kept. The conventional method (BC) showed thermal damage in the layer that was ground for all conditions tested and the residual stress values of the ground... (Complete abstract click electronic access below)
|
20 |
Usinabilidade do aço DIN C45 trefilado de alta resistência /Miguel, José Gerez. January 2014 (has links)
Orientador: Marcos Valério Ribeiro / Banca: José Vitor Candido de Souza / Banca: Amauri Hassui / Resumo: Este trabalho é uma proposta para facilitar a quantificação da usinabilidade de um material de alta resistência destinado à produção de peças de segurança para indústria automotiva. A complexidade dos processos de usinagem necessita do desenvolvimento de um método de avaliação da usinabilidade nas mãos de quem produz o material e, pelo grande número de parâmetros envolvidos, dificulta a rápida e precisa obtenção de resultados. A evolução tecnológica tende a desenvolver materiais com melhores propriedades mecânicas e com microestruturas mais refinadas que oferecem maior resistência à usinagem. Neste trabalho foram desenvolvidas ferramentas que permitiram simular uma situação real de usinagem de barras do aço DIN C45, por torneamento radial. O objetivo do trabalho foi avaliar os parâmetros do processo atualmente utilizado, bem como, estabelecer um padrão de referência para aferição, no próprio fornecedor, de melhorias implantadas neste produto. Como resultado foi possível confirmar que o avanço e a rotação atualmente utilizados estão perfeitamente adequados. Entretanto, outro ângulo de saída proposto apresentou aumento significativo da vida da ferramenta nas várias condições testadas. Foi possível realizar a quantificação da usinabilidade, conforme a intenção inicial deste trabalho / Abstract: This is work is a proposal to quantify the machinability of a high strength material for safety parts production in automotive industry. The complexity of machining processes requires development of an evaluation method of machinability that can be done by those who produce the material before the end-user involvement and, mainly due to large number of parameters involved, it's difficult to obtain fast and accurate results. Technological evolution leads to the development of materials with improved mechanical properties and finer microstructures that offer greater resistance to machining. This work aimed to establish tools that simulated a real situation machining grade DIN C45 steel bars. The goal was to evaluate the process parameters used currently and also to establish a benchmark for evaluation in laboratory for future improvements to be incorporated in the steel bar. In this evaluation, it was confirmed that the advance and speed currently used are perfectly adequate. However, another angle output proposed achieved superior results, significantly increasing tool life in several conditions tested / Mestre
|
Page generated in 0.0538 seconds