• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 93
  • 1
  • Tagged with
  • 94
  • 77
  • 76
  • 67
  • 49
  • 39
  • 21
  • 20
  • 18
  • 18
  • 17
  • 15
  • 14
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Tratabilidade de efluentes provenientes de duas seqüências ECF de branqueamento de celulose kraft de eucalipto / Treatability of two bleached ECF effluents of kraft pulp eucalyptus

Souza, Luciana Cerqueira 31 July 2001 (has links)
Submitted by Nathália Faria da Silva (nathaliafsilva.ufv@gmail.com) on 2017-07-07T19:58:11Z No. of bitstreams: 1 texto completo.pdf: 332385 bytes, checksum: 6f6e82412f5c5185839844aa2f41ad9b (MD5) / Made available in DSpace on 2017-07-07T19:58:11Z (GMT). No. of bitstreams: 1 texto completo.pdf: 332385 bytes, checksum: 6f6e82412f5c5185839844aa2f41ad9b (MD5) Previous issue date: 2001-07-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente trabalho buscou simular, em escala de laboratório, um sistema de lodos ativados em batelada e em série, a fim de avaliar a tratabilidade dos efluentes provenientes de duas seqüências de branqueamento ECF, geradas em laboratório: A(EOP)D(PO) e D HOT (EOP)DP. Foi realizado o mesmo estudo com um efluente industrial de branqueamento ECF de uma fábrica de celulose kraft de eucalipto. Inicialmente, os efluentes foram caracterizados e tratados biologicamente, e em seguida foram realizados testes para estimar os parâmetros cinéticos do crescimento biológico do sistema de tratamento empregado para cada efluente. Os efluentes apresentaram características próximas. O primeiro reator biológico foi eficiente quanto à remoção de DQO (73%), DBO5 (98%) e AOX (50%), para ambos os efluentes, e compatível com os níveis atuais alcançados por fábricas de celulose kraft branqueada. Porém, o segundo reator biológico do sistema em série não foi eficiente, uma vez que praticamente toda matéria orgânica biodegradável existente nos efluentes foi consumida no primeiro reator. A taxa máxima de crescimento da biomassa estimada para o efluente gerado no laboratório foi de aproximadamente 1,3 d^-1, enquanto o efluente industrial apresentou uma taxa xinferior, em torno de 0,6 d^-1. Os coeficientes de produção celular estimados para ambos os efluentes estudados foram próximos, em torno de 0,4 mgSSV mgDQO^-1. Este valor encontra-se próximo do disponível na literatura, para efluentes de celulose kraft. Quanto ao coeficiente de respiração endógena estimado, o efluente laboratorial apresentou valor próximo ao da literatura, 0,13 d^-1, já o efluente industrial apresentou um valor superior, em torno de 0,18 d^-1. / This study tried to simulate in laboratory, a batch activated sludge system to treat two laboratory generated ECF bleaching effluents, A(EOP)D(PO) and D HOT (EOP)DP as well as an industrial eucalyptus kraft pulp ECF bleaching effluent. The effluents were characterized, bio-treated and finally growth kinetics parameters of the biological system used to treat the effluents were estimated. The effluents had similar characteristcs. The first biological reactor shaved efficient COD (73%), BOD (98%) and AOX (50%) removal for both effluents which was comparable to that observed for bleached kraft pulp mill effluents. However, the second biological reactor wasn’t efficient because all effluent biodegradable organic material was oxidized in the first reactor. A estimate of the biomass maximum specific growth rate in the laboratory effluent was 1.3 d^-1, however the rate in the industrial effluent was 0.6 d^-1. The estimates of the yield coefficients in both effluents were similar, 0.4 mgVSS mgCOD^-1, and similar to values found in the literature for pulp effluents. The estimate of the endogenous decay coefficient in the laboratory effluent was similar to values reported in the literature, 0.13 d^-1, however that of the industrial effluent was higher, 0.18 d^-1.
22

Avaliação bioquímica e molecular dos receptores ativados por proteases (PARs) em modelos de privação de sono / Biochemistry and molecular evaluation of protease activated receptors (PARs) in sleep deprivation models

Scanapieco, Sergio de Freitas [UNIFESP] January 2012 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:45:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2012 / Associação Fundo de Incentivo à Psicofarmacologia (AFIP) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / A funcao do sono ainda nao foi completamente elucidada, porem se sabe que este tem papel homeostatico, e na sua privacao, ocorrem diversas alteracoes fisiologicas e patologicas, como no sistema imunologico e na reacao inflamatoria. A trombina e considerada como um agente pro-inflamatorio por ser capaz de estimular as celulas a liberar mediadores pro-inflamatorios. A familia dos Receptores Ativados por Proteases (PARs) e composta por quatro receptores acoplados a proteina G (GPCRs): PAR1, PAR2, PAR3 e PAR4, que sao ativados unicamente por proteases. O principal papel da ativacao dos PARs durante a progressao de doencas foi relatado em modelos animais de diferentes patologias gastrointestinais, neuroinflamatorias e processos neurodegenerativos. Os PARs estao diretamente envolvidos no funcionamento e desenvolvimento do cerebro. Suas expressoes sao diretamente moduladas por condicoes anormais, como doenca de Parkinson e Alzheimer, esclerose multipla e demencia associada ao HIV. Apesar do reconhecimento da privacao de sono como um importante problema de Saúde na sociedade moderna, nao existem estudos sobre o efeito da privacao de sono sob os receptores PARs. Objetivos: Analisar e quantificar a expressao genica dos PARs e a traducao proteica em regioes selecionadas do sistema nervoso central, em diferentes protocolos de privacao de sono. Metodos: Os animais foram separados em 6 grupos: 1) animais privados de sono paradoxal (PS) por 72h, usando o metodo das plataformas multiplas; 2) PS por 72h e rebote de sono por 24h; 3) animais restritos de sono paradoxal (RS) por 15 dias, permitindo sono de 3h por dia, tambem usando o metodo das plataformas multiplas; 4) RS de sono por 15 dias e rebote de sono por 24h; 5) animais privados de sono total pelo metodo de gentle handling (GH) por 8h; 6) grupo controle. Apos a privacao de sono, os animais tiveram o cortex, hipotalamo, hipocampo e estriado removidos e foram feitas as quantificacoes genicas e proteicas do PAR1, PAR2 e PAR4. Resultados: Foram encontradas alteracoes nas expressoes genicas dos receptores PARs nos tecidos estudados. No cortex, houve alteracao na expressao genica (+ ou- significa aumento ou reducao) no PAR1 (RS-, RRS-, PS-, RPS-) e PAR2 (RS-, RRS-, PS-, RPS-, GH+) mas nao em PAR4. No hipotalamo, foram encontradas alteracoes no PAR1 (RS+, PS+, RPS+) e PAR2 (GH-), nao sendo encontrada nenhuma alteracao no PAR4. Analisando o hipocampo, foram encontradas alteracoes no PAR1 (RS+, GH+), PAR2 (RS-, PS+, RPS+) e PAR4 (RS-, GH-). No estriado, houve alteracoes no PAR1 (RS-, RRS-), PAR2 (RPS+) e PAR4 (RRS+, PS+, RPS+). A quantificacao proteica mostrou alteracoes no PAR2 (PS-) e PAR4 (PS-, RPS) do estriado. No hipocampo, PAR2 (RRS+) e PAR4 (RRS+) mostraram alteracoes significantes. Encontramos alteracoes significantes no PAR1 (RS-, RRS-) no hipotalamo. Conclusao: Diferentes protocolos de privacao de sono podem alterar, de diferentes maneiras, a expressao genica e a traducao proteica dos PARs no sistema nervoso central. Um novo campo de pesquisa em Ciências do sono esta aberto e mais estudos sao necessarios para estabelecer a correlacao entre as alteracoes na expressao dos PARs e inflamacao, reacoes imunes e alteracoes neurais observadas em modelos de privacao de sono / BV UNIFESP: Teses e dissertações
23

Estudo do comportamento da DBO em suporte aeróbio de oxigênio puro: coeficientes cinéticos e fatores de correlação / I study of the behavior of DBO in support aerobic of pure oxygen: kinetic coefficients and correlation factors

Barbosa, João Marcelo do Nascimento January 2003 (has links)
Made available in DSpace on 2012-09-06T01:11:30Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 598.pdf: 9014270 bytes, checksum: 50ddc5b9b9f3b1a57694ee2b65989074 (MD5) Previous issue date: 2003 / Os sistemas de tratamento de esgotos por lodos ativados, utilizando como suporte aeróbio o oxigênio puro, vem sendo utilizados cada vez com maior freqüência no tratamento de efluentes industriais e, recentemente, no tratamento de esgotos domésticos. No dimensionamento destes sistemas de tratamento tem sido utilizada uma DBO, que utiliza oxigênio puro como suporte aeróbio, que reflete de forma mais realista a eficiência destes sistemas na remoção da matéria orgânica biodegradável. Apesar da grande importância desta DBO modificada não há referências na literatura sobre a sua cinética. Neste trabalho foi estudada a diferença entre os coeficientes cinéticos e os graus de eficiência na remoção da matéria orgânica biodegradável, de um sistema que utilize para análise de DBO um suporte aeróbio tradicional (DBOt), e de outro que utilize oxigênio puro como suporte aeróbio (DBOm). A metodologia operacional desta pesquisa foi baseada na realização de análises para avaliação do comportamento da DBO, quando em meio de ar atmosférico ou em meio de oxigênio puro através da incubação por cinco dias a 20oC e com leitura de oxigênio dissolvido, realizada diariamente, pelo método Winkler. Os resultados das análise demonstraram significativa diferença entre os valores da DBOt e da DBOm, foi obtido um fator de correlação da razão DBOm/DBOt de 1,523 mais ou menos 0,103, demonstrando um aumento da eficiência na remoção da matéria orgânica de cerca de 50 por cento, pelo uso do oxigênio nas condições do ensaio. Através destes resultados obtidos, foram calculados os coeficientes cinéticos (K) associados à redução da DBO; tanto tradicional (DBOt) quanto modificada (DBOm). Além dos aspectos técnicos dos sistemas de tratamento com oxigênio puro, descritos sucintamente neste trabalho, foi realizada uma investigação das aplicações destes sistemas no Brasil, com ênfase em sua evolução histórica entre as décadas de oitenta e noventa. Nesta pesquisa, de cunho mercadológico, da evolução histórica desta técnica de tratamento, foi realizada uma pesquisa de campo com entrevistas aos gerentes de marketing das empresas que fabricam sistemas de aeração com oxigênio puro para tratamento de efluentes. Como resultado desta investigação, é apresentado no capítulo três um consolidado de caráter qualitativo.
24

Estudo do envolvimento do receptor nuclear PPARy na inflamação pulmonar induzida pelo componente de Quorum Sensing de pseudomonas aeruginosa 3-oxo dodecanoil homoserina lactona

Menezes, Clarissa Campbell January 2011 (has links)
Submitted by Anderson Silva (avargas@icict.fiocruz.br) on 2012-10-26T17:48:32Z No. of bitstreams: 1 clarissa_c_menezes_ioc_bcm_0054_2011.pdf: 2530597 bytes, checksum: 62f04a75c90de18a85463693ba14fb9b (MD5) / Made available in DSpace on 2012-10-26T17:48:32Z (GMT). No. of bitstreams: 1 clarissa_c_menezes_ioc_bcm_0054_2011.pdf: 2530597 bytes, checksum: 62f04a75c90de18a85463693ba14fb9b (MD5) Previous issue date: 2011 / Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Rio de Janeiro, RJ, Brasil. / A bactéria Pseudomonas aeruginosa (PA) é um dos principais agentes etiológicos de pneumonias nosocomiais, cujo tratamento é dificultado por sua resistência a antibióticos e pela secreção de fatores de virulência. Novas alternativas para o tratamento destas infecções incluem manipular o sistema de comunicação bacteriano conhecido como quorum sensing (QS), reduzindo a expressão destes fatores de virulência e prevenindo seus efeitos deletérios em células e sistemas eucariotos. Os efeitos do componente de QS de PA 3-oxo dodecanoil homoserina lactona (3-oxo C12 HSL) nos pulmões não são conhecidos; portanto, a primeira etapa de nosso trabalho consistiu na caracterização dos efeitos desta molécula no ambiente pulmonar. Para isso, camundongos swiss desafiados com 3-oxo C12 HSL por via intratraqueal tiveram amostras de sangue, lavado bronco-alveolar (BAL) e tecido pulmonar e coletadas seis horas após o procedimento. Nossos resultados demonstram que inflamação pulmonar causada por 3-oxo C12 HSL se caracteriza pela migração de células mononucleares e neutrófilos para o espaço alveolar, níveis elevados de atividade mieloperoxidase no tecido pulmonar e formação de edema. A resposta inflamatória causada por 3-oxo C12 HSL não alterou os níveis de TNF-α, MIF, IL- 10 e IL-12 no tempo analisado. Foram observados aumentos nos níveis de IL-6, CCL2/MCP-1, CXCL1/KC e LTB4 no BAL de animais desafiados, sendo o aumento deste eicosanóide acompanhado por uma indução de corpúsculos lipídicos. Evidências in vitro relatam o envolvimento do receptor nuclear PPARγ nos efeitos pró-inflamatórios atribuídos a 3-oxo C12 HSL; portanto, decidimos estudar os efeitos do tratamento com o agonista de PPARγ rosiglitazona no modelo de inflamação pulmonar causado por este componente de QS. Nós observamos que o tratamento com rosiglitazona (0,5 mg/kg) uma hora após o estímulo diminuiu a formação de corpúsculos lipídicos e de edema pulmonar, causando também uma redução na migração de células mononucleares e neutrófilos e uma menor atividade mieloperoxidase no pulmão dos animais tratados. A redução da migração de células mononucleares parece estar associada à uma redução dos níveis de CCL2/MCP-1, enquanto o decréscimo nos neutrófilos parece envolver a modulação de CXCL1/KC. A instilação com 3-oxo C12 HSL diminuiu a expressão da enzima paraoxonase (PON) no tecido pulmonar, fenômeno que não foi revertido pelo tratamento com rosiglitazona nesta dose. Estudos demonstram que o PPARγ está envolvido na expressão de PON e que a superexpressão desta enzima é capaz de proteger animais da mortalidade por PA em função de sua atividade lactonase; por este motivo, decidimos testar uma dose maior de rosiglitazona (5 mg/kg) para alcançar mais um benefício nesta proposta terapêutica. O tratamento com rosiglitazona nesta dose foi capaz de reverter a redução da expressão de paraoxonase causada por 3-oxo C12 HSL, diminuindo a formação de edema, a migração de neutrófilos e os níveis de atividade mieloperoxidase no pulmão de animais desafiados. O número de células mononucleares recuperado no BAL de animais estimulados e tratados com a droga não foi reduzido, bem como os níveis de CCL2/MCP-1. De fato, a droga por si só causou um aumento de CCL2/MCP-1 que parece ter contribuído para a indução de corpúsculos lipídicos observada. Devido ao envolvimento de macrófagos e da quimiocina CCL2/MCP-1 no processo de eliminação bacteriana, estudos em modelos de pneumonia por PA precisam ser conduzidos para melhor avaliar esta dose de rosiglitazona e validar esta droga como uma estratégia terapêutica no combate à esta bactéria. / Pseudomonas aeruginosa (PA) is a major pathogen involved in nosocomial pneumonia. These infections are difficult to manage due bacterial antibiotic resistance and secretion of virulence factors; therefore, current approaches to treat PA infections now focus on manipulating the bacteria communication system known as quorum sensing in order to reduce the production of those virulence factors and mitigate their deleterious effects to the host. Since there are no reports about the effects of the PA main quorum sensing component 3-oxo dodecanoyl homoserine lactone (3-oxo C12 HSL) in the lung the first step of our work consisted in investigating the host pulmonary response to this molecule in a mouse model. In order to do so, swiss mice submitted to intratracheal instillation with 3- oxo C12 HSL had blood, BAL and lung tissue samples collected six hours after the procedure. Our results show that the inflammatory response elicited by 3-oxo C12 HSL is characterized by the migration of both mononuclear cells and neutrophils to the alveolar space, together with high levels of myeloperoxidase activity in lung tissue and development of pulmonary edema. We found that the levels of TNF-α, MIF, IL-10 and IL-12 were not altered, while there was a significant increase in IL-6 CCL2/MCP-1 and CXCL1/KC in BAL. The increase in LTB4 levels in the BAL of defied animal was accompanied by an induction of lipid bodies. In vitro evidences report the involvement of the nuclear receptor PPARγ in the inflammatory events ascribed to 3-oxo C12 HSL; therefore, we decided to study the effects of PPARγ agonist rosiglitazone in the pulmonary inflammation caused by this quorum sensing component. We observed that rosiglitazone administration (0,5 mg/kg) one hour after stimulation was able to reduce the formation of lipid bodies and pulmonary edema, besides decreasing the migration of mononuclear cells, neutrophils and myeloperoxidase activity in the lung of defied animals. This reduction in the migration of mononuclear cells seems to be due to a decrease in the levels of CCL2/MCP-1, while the impairment in neutrophil migration seems to involve the modulation of CXCL1/KC. 3-oxo C12 HSL instillation also decreased paraoxonase (PON) expression in lung tissue, which was not reverted by rosiglitazone treatment at this dose. Since it was reported that PPARγ is able to regulate PON expression and that the overexpression of this enzyme seems to protect animals from PA mortality due its lactonase activity we searched to modulate this enzyme with a higher dose of rosiglitazone (5 mg/kg) in order to achieve this extra benefit in our proposal. We observed that this dose was able to revert the decrease in PON expression caused by 3-oxo C12 HSL, reducing the pulmonary edema, neutrophil migration and myeloperoxidase activity in defied animals. There was no reduction in the number of mononuclear cells recovered from the BAL of stimulated animals, which was also observed for CCL2/MCP-1 levels. In fact, the drug itself at his dose caused an increase in CCL2/MCP-1 that possibly accounted for the induction of lipid bodies. Because macrophages and CCL2/MCP-1 have a crucial role in the clearance of bacteria, this dose of rosiglitazone has to be tested in a PA pneumonia model so the effects observed in our investigation can be validate rosiglitazone as an therapeutic approach to the treatment of these infections.
25

Efeito do recebimento de lodos oriundos de estações de tratamento de água nos processos de tratamento de esgotos por lodos ativados convencional. / Effects of Water Treatment Plant (WTP) sludge on a Waste Water Treatment Plant (WWTP) with active sludge process.

André Luiz Marguti 13 April 2012 (has links)
Por razões técnicas e ambientais, o lodo gerado no tratamento de águas para abastecimento público deve ser adequadamente tratado antes de ser disposto no meio ambiente. Uma alternativa é a disposição do lodo de ETA em ETE, o que dispensa a implantação da linha de tratamento do lodo na ETA. O objetivo deste trabalho foi estudar os impactos ocorridos na ETE ABC, estação de lodos ativados convencional operada pela SABESP, devido ao recebimento do lodo da ETA Rio Grande. Trata-se de caso particular, pois envolve instalações reais, e pelo fato de a ETA apresentar vazão próxima de três vezes a vazão da ETE (vazão de lodo corresponde a 0,1% da vazão da ETE). Os dados utilizados incluem variáveis de qualidade do efluente (DBO, DQO, SST, SSV, nitrogênio amoniacal e total, fósforo e ferro) e do lodo (sólidos), e parâmetros operacionais das unidades da ETE (vazões, taxas de aplicação superficial e de sólidos, idade do lodo, tempo de detenção, entre outros). Foi possível analisar o processo de tratamento na ETE e comparar seu desempenho entre dois períodos: controle (anos de 2005 e 2006) e com lodo (janeiro de 2007 a março de 2008). Nestes períodos, a ETE operou com 50% de sua capacidade (taxas de aplicação abaixo dos valores de projeto), idade do lodo de 4 dias e taxa de reciclo em torno de 80%. No período com lodo, as variáveis que apresentaram maior aumento de concentração no esgoto afluente foram SST, SSV, fósforo e ferro; o lodo da ETA contribuiu para maiores eficiências de tratamento da fase líquida na ETE, uma vez que houve a manutenção da qualidade do efluente final, nos níveis exigidos pela legislação, mesmo com o aumento das concentrações afluentes. Este aumento de eficiência foi mais acentuado para o fósforo (de 52% para 88%), e maior no tratamento primário, com variações nos parâmetros operacionais que não influíram negativamente no desempenho das unidades. No tratamento de lodo, o maior impacto causado foi o aumento na produção final de lodo (de 50 t/d para 76 t/d). Tais conclusões são então favoráveis ao lançamento de lodos de ETA convencional em ETE de lodos ativados convencional, mesmo nos casos em que a vazão tratada na ETA exceda em muito a vazão da ETE. / For technical and environmental reasons, sludge from water treatment plants should be properly treated before being discharged into the environment. An emerging practice is the disposal of such sludge in WWTP, an alternative that does not require the installation of sludge treatment facilities in the WTP. The main purpose of this research was to study the impacts at the ABC WWTP, an activated sludge process facility operated by SABESP and located in São Paulo, Brazil, due to receiving sludge from the Rio Grande WTP, also located in the same region. It is a particular case due to the fact that the WTP provides a flow of three times the flow treated in the WWTP (sludge flow is 0,1% of WWTP flow). The used data include effluent quality variables (BOD, COD, TSS, VSS, ammonia and total nitrogen, phosphorus and iron), sludge (solids) and WWTP units operational parameters (flow, surface and solid application rates, sludge retention time, hydraulic detention time, among others). It was possible to analyze the treatment process at the WWTP and compare its performance between two periods: control (years 2005 and 2006) and with sludge (from January 2007 to March 2008). In these periods, the WWTP worked with half of its capacity (all loading rates stayed below design values), sludge retention time of 4 days and recycle rate around 80%. In the with sludge period, the quality variables with the highest inflow concentration increase were TSS, VSS, phosphorus and iron. During the same period, the WTP sludge contributed to greater efficiencies in the WWTP treatment process, since the effluent quality was maintained under levels legally required, even with the increase of influent concentrations. This fact is mostly evident in the case of phosphorus (from 52% to 88%), and higher in primary treatment, with changes in operational parameters that did not adversely affect the units performances. In solid phase treatment, the most important impact was the increase in final sludge production (from 50 t/d to 76 t/d). These conclusions are then favorable to the disposal of sludge from conventional WTP in an activated sludge WWTP, even in cases in which the flow treated in the WTP far exceeds the WWTP flow.
26

Avaliação das diferentes condições operacionais na formação de grânulos aeróbios utilizando reatores em bateladas sequenciais na remoção de nitrogênio e fósforo de esgoto sanitário

SILVA, Poliana Maria Januário 31 March 2017 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-07-31T20:41:10Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Poliana Maria Januário Silva.pdf: 2083587 bytes, checksum: 3de5791d497c5458f7424c297efd1fd4 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-07-31T21:14:09Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Poliana Maria Januário Silva.pdf: 2083587 bytes, checksum: 3de5791d497c5458f7424c297efd1fd4 (MD5) / Made available in DSpace on 2018-07-31T21:14:09Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Poliana Maria Januário Silva.pdf: 2083587 bytes, checksum: 3de5791d497c5458f7424c297efd1fd4 (MD5) Previous issue date: 2017-03-31 / FACEPE / Avaliação das diferentes condições operacionais na formação de grânulos aeróbios utilizando reatores em bateladas sequenciais na remoção de nitrogênio e fósforo de esgoto sanitário Os reatores com lodo granular aeróbio dispensam a presença de material suporte, e os grânulos podem atuar na remoção simultânea de matéria orgânica, nitrogênio e fósforo, devido à formação de camadas ou zonas aeróbia, anóxica e anaeróbia. Os grânulos aeróbios se desenvolvem, especialmente, em reatores em bateladas sequenciais (RBS), com alta relação altura/diâmetro (H/D) e utilizando esgotos com elevada carga orgânica volumétrica. No presente trabalho, o objetivo foi estudar o desenvolvimento de grânulos aeróbios utilizando dois reatores RBS, em escala piloto, tratando esgoto sanitário e aplicando média e baixa carga orgânica volumétrica. Os reatores foram operados em ciclos de 3 h com diferentes trocas volumétricas (Tv), diferentes tempos de sedimentação e diferentes velocidades ascensionais de ar (Va). Na etapa operacional I (EOP I), os RBS denominados de reatores R1.I e R2.I foram operados com iguais tempos de sedimentação e Va (1,4 cm∙s⁻¹). A granulação somente ocorreu no reator R1.I com Tv de 59%. A baixa idade média do lodo ocasionada pela Tv de 71% impediu a formação de grânulos no reator R2.I. As eficiências médias de remoção de demanda química de oxigênio total (DQOt) foram de 88% para ambos os reatores. Porém, a eficiência média de remoção de N-NH4⁺, no reator R1.I, foi 25% maior do que no R2.I. As eficiências médias de remoção de fósforo e ortofosfato em ambos os reatores foram 46 e 27%, respectivamente. Na etapa operacional II (EOP II), os RBS foram denominados de R1.II, R2.II e R3.II (= R2.II reiniciado). Durante a EOP II, os grânulos se desenvolveram em todos os reatores. Na EOP II, as Va aplicadas foram de 0,88 cm∙s⁻¹ para os reatores R1.II e R3.II e 1,06 cm∙s⁻¹ para o reator R2.II. Com relação às eficiências médias de remoção de DQOt e DQO solúvel (DQOs), não foi observada diferença entre os três reatores, ao nível de confiança de 95%. A eficiência média de remoção de N-NH4⁺, no reator R3.II, foi 44% maior do que no R1.II, ocasionada pela troca volumétrica de 71% utilizada no reator R1.II, que ocasionou a lavagem da biomassa nitrificante deste reator. A maior eficiência média de remoção de fósforo de 42% foi verificada no reator R1.II onde os grânulos permaneceram por mais de 40 dias. Ainda em relação à EOP II, a formação dos grânulos, com até 4,0 mm de diâmetro, não foi condição suficiente para uma alta remoção de fósforo. O processo de granulação no reator R1.I, com Tv de 71%, demandou mais tempo, porém, os grânulos depois de formados permaneceram por mais tempo no reator. Em geral, é possível desenvolver grânulos maduros em RBS, aplicando baixa Va, no tratamento de esgoto sanitário de média e baixa carga orgânica. / The reactors with aerobic granular sludge do not require the presence of support material, and the granules can remove simultaneously the organic matter, nitrogen and phosphate, due to the presence of aerobic, anoxic and anaerobic zones. The development of aerobic granules occurs especially in sequential batch reactors (SBR), with high height/diameter (H/D) ratio and by applying sewage with high volumetric organic load. In the the present work, the as objective was to study the development of aerobic granules using two pilot-scale SBR treating sanitary sewage by applying medium and low volumetric organic loads. The operating cycle time was 3 hour with different volumetric exchanges, sedimentation times and superficial upflow air velocities (Va). In the operational stage I (OPS I), the SBR namely as reactors R1.I and R2.I were operated with the same sedimentation times and va (1.4 cm∙s⁻¹). The granulation only occurred in reactor R1.I with volumetric exchange of 59%. The low sludge age caused by volumetric exchange of 71% prevented the formation of granules in reactor R2.I. The average removal efficiencies of total chemical oxygen demand (CODt) were 88% for both reactors. However, the average removal efficiency of NH4⁺-N in reactor R1.I was 25% higher than in R2.I. The average removal efficiencies of phosphorus and orthophosphate in both reactors were 46 and 27%, respectively. In the operational step II (OPS II), the SBR were identified as reactors R1.II, R2.II and R3.II (= R2.II restarted). During OPS II, the granules were developed in all reactors. In the OPS II, the va applied were 0.88 cm∙s⁻¹ for the reactors R1.II and R3.II and 1.06 cm∙s⁻¹ for reactor R2.II. Regarding the average removal efficiencies of CODt and soluble COD (CODs), no difference was observed between the three reactors at the confidence level of 95%. The average removal efficiency of NH4⁺-N in reactor R3.II was 44% higher than in reactor R1.II, because of the 71% volumetric exchange used in the R1.II reactor resulted in the washing of the nitrifying biomass of the reactor. The highest average removal efficiency of phosphorus of 42% was verified in reactor R1.II where the granules remained for more than 40 days. Also with respect to OPS II, the formation of the granules, up to 4.0 mm in diameter, was not a sufficient condition for an high phosphorus removal. The granulation process in the reactor R1.I, with volumetric exchange of 71%, required more time, but the granules after formed remained longer in the reactor. In general, it is possible to develop mature granules in RBS applying low va in the treatment of sanitary sewage with medium and low load.
27

Propriedades antiaterogênicas de novas tiazolidino-2,4-dionas / Antiatherogenic properties of new thiazolidin-2,4-diones

Fernanda Andrade de César 20 March 2013 (has links)
Tiazolidinadionas (TZDs) são agentes sensibilizadores de insulina que agem por ligação ao receptor gama ativado por proliferador de peroxissomos (PPARγ). Elas têm apresentado efeitos cardioprotetores em humanos e propriedades anti-aterogênicas em modelos animais. Estudos in vitro têm sugerido que esses efeitos anti-aterogênicos da ativação de PPARγ ocorrem por inibição da expressão de genes pro-inflamatórios e por aumentar o efluxo de colesterol via ativação dos receptores LXR-ABCA1. Entretanto, vários efeitos colaterais são associados ao tratamento com as TZDs, tornando necessária a pesquisa por novos compostos desta classe. Neste estudo, 14 novas tiazolidina-2,4- dionas, que são TZDs modificadas por bioisosterismo, foram avaliadas quanto à expressão de fatores aterogênicos e inflamatórios em linhagens de macrófagos J774 e RAW 264.7 e em camundongos com deleção genética para o receptor de LDL (LDLr-/-). Após a avaliação da citotoxicidade em macrófagos, foram eleitas cinco TZDs, denominadas de GQ-11, GQ-97, GQ-177, GQ-145 e LYSO-7. Três destas TZDs (GQ- 145, GQ-177 e LYSO-7) aumentaram significativamente a expressão de RNAm dos fatores de transcrição PPARγ1, PPARγ2 e do receptor CD36, assim como também aumentaram a expressão gênica de ABCA1 em 2.9, 3.5 e 6.7 vezes, respectivamente. Em adição, estas TZDs diminuíram a expressão gênica de iNOS, COX2, VCAM e IL-6 associado a redução na produção de nitritos, mas apenas a LYSO-7 reduziu significativamente a expressão desses genes quando comparada à rosiglitazona (RSG), além de diminuir a expressão da proteína-1 quimiotática para monócitos (MCP-1). No estudo experimental, os camundongos LDLr-/- machos foram alimentados com dieta hipercolesterolêmica por 16 semanas e quatro semanas antes da eutanásia receberam os derivados tiazolidínicos (20 mg/kg/dia) por gavagem. GQ-177 inibiu a progressão da placa aterosclerótica associada à aumento nas concentrações plasmáticas de HDL-C, com elevação na expressão de ABCA1, e redução da via inflamatória CD40-CD40L. LYSO-7 também mostrou inibição da aterogênese associada à redução das concentrações plasmáticas de colesterol total e triacilgliceróis, com diminuição na interação entre CD40-CD40L e expressão de citocinas inflamatórias. A GQ-145 não alterou os níveis plasmáticos dos lipídeos, mas aumentou a expressão de todos os genes pró-aterogênicos e pró-inflamatórios. Adicionalmente, as vias de ativação destas novas TZDs também foram estudadas por ensaio de luciferase, como gene repórter. A GQ-177 induziu ativação de PPARγ e ligação ao seu domínio, enquanto a LYSO-7 estimulou ativação de PPARα e PPARδ. Portanto, conclui-se que as novas TZDs, especialmente a GQ-177 e a LYSO-7, podem apresentar propriedades ateroprotetoras associadas ao transporte reverso de colesterol e aos efeitos antiinflamatórios, e poderiam ser uma alternativa promissora para o tratamento da aterosclerose. Porém, estudos complementares são requeridos para caracterizar as vias de sinalização intracelular, visto que as duas demonstraram ativar diferentes isotipos do fator de transcrição PPAR. / Thiazolidinediones (TZDs) are insulin-sensitizing agents that act by binding to peroxisome proliferator-activated receptor-γ (PPARγ). They have been demonstrated to possess cardioprotective effects in humans and antiatherogenic properties in animal models. In vitro studies have also suggested that these antiatherogenic effects of PPARγ activation occur by inhibiting the inflammatory gene expression and by increasing cholesterol efflux via LXR-ABCA1 activation. However, several side effects are associated with TZDs treatment making necessary the search for new compounds. In this study, 14 new thiazolidine-2,4-diones, modified TZDs by bioisosterism, were tested for aterogenic and inflammtary factors in RAW 264.7 macrophages and in low-density lipoprotein receptor-deficient mice. After the citotoxicity evaluation in RAW 264.7 macrophages the TZDs named GQ-11, GQ-97, GQ-177, GQ-145 e LYSO-7 were selected for this study. Three of these TZDs (GQ-177, GQ-145 and LYSO-7) significantly increased the expression of PPARγ1, PPARγ2 and CD36 mRNA, and enhanced the expression of ABCA1 mRNA in 2.9, 3.5 and 6.7 fold, respectively. Moreover, they also significantly decreased the expression of iNOS, COX2, VCAM and IL-6 mRNA in relation to control, and these results are associated to reduction on nitrits concentration. In addition, LYSO-7 significantly reduced the expression of these genes when compared to rosiglitazone, and decreased expression of MCP1 mRNA. In the experimental study, male LDLr-/- mice were fed an atherogenic diet containing 0.5% cholesterol for 16 weeks, and 4 weeks before euthanasia they received TZDs (20mg/kg/ per day) by gavage. GQ-177 treatment inhibited progression of atherosclerotic plaque associated to increased plasma concentrations of HDL-C, with enhance of ABCA1 expression and reduction on CD40-CD40L interaction. LYSO-7 treatment also showed inhibition of the atherogenesis associated to decreased plasma concentrations of total cholesterol and TAG, with reduction on CD40-CD40L pathway and inflammatory cytokines expression.GQ-145 did not alter the lipid plasma levels and increased the expression of all pro-atherogenic and pro-inflammatory genes. Furthermore, the activation of PPARs has also been studied, by luciferase assay as reporter gene. GQ-177 induced activation of PPARγ, whereas LYSO-7 stimulated activation of PPARα and PPARβ/δ. Altogether, our data suggest that the new TZDs derivatives, specially GQ- 177 and LYSO-7, may have atheroprotective properties associated with the reverse cholesterol transport and anti-inflammatory effects, and could be a promising alternative for the treatment of atherosclerosis. However, further studies are warranted in order to characterize the pathways of intracellular signaling since both have demonstrated to activate different isotypes of PPAR.
28

Determinação das frações orgânicas de efluentes de reatores UASB. / Determination of organic fractions of UASB reactors efluents.

Moacir Francisco de Brito 19 October 2006 (has links)
O tratamento de esgotos municipais através de reatores do tipo \"Up-flow Anaerobic Slugde Blanket\" - UASB, já são utilizados há vários anos em alguns estados do Brasil. Seu rendimento no tratamento está na faixa de 65 a 75% de remoção de carga orgânica medida em DBO, necessitando portanto de um pós - tratamento, por exemplo AERÓBIO, como Filtros Biológicos Percoladores, Filtros Biológicos submersos Aerados, Lodos Ativados etc. Devido a evolução da legislação e dos sistemas de tratamento no nível terciário, ou seja, remoção de nutrientes, estes pós - tratamentos se fazem ainda mais necessários para remoção de nitrogênio amoniacal por exemplo, com remoção completa usando de nitrificação e denitrificação ou simplesmente atingindo o estágio de nitrificação, pois o nitrogênio amoniacal é tóxico para uma boa parcela da vida aquática, peixes principalmente, enquanto o nitrogênio na forma do íon nitrato ou nitrito é considerado menos tóxico. Já existe na literatura algumas descrições de como dimensionar tais unidades de pós - tratamento, todavia, os parâmetros usados são teóricos e baseados nos já existentes para esgotos sanitários tipicamente domésticos, não havendo ainda uma fonte de dados experimentais para tais parâmetros. O intuito deste trabalho foi o de obter dados mais reais para projeto de pós - tratamento de efluentes de reatores UASB, usando o equacionamento e os métodos apresentados por Ekama, Dold e Marais (1986), baseado num sistema piloto de Lodos Ativados, em escala de laboratório, alimentado com efluente de um reator UASB instalado no campus da USP, mais precisamente no Centro Tecnológico de Hidráulica (CTH) da Escola Politécnica. Este reator trata o esgoto gerado no restaurante comunitário e apartamentos de moradia dos alunos (CRUSP), da Universidade. Como todos os sistemas biológicos aeróbios de tratamento se baseiam nas mesmas frações, os dados aqui obtidos são úteis para qualquer outro pós - tratamento aeróbio destes efluentes. As frações obtidas foram: fup = 0,15, frb ~0 e fus= 0,2. / The treatment of municipal wastewaters through \"Up-flow Anaerobic with Sludge Blanket\" - UASB reactors -, are already used for many years in some states of Brazil. It\'s output in the treatment is in the range of 65% to 75% of organic load remove in BOD, needing so an after-treatment, for example the AEROBIC, like Percolator Biologic Filters, aerated submerse Biological Filters, Activated Sludge etc. Due to the evolution of legislation and treatment systems in the tertiary level, that means, nutrients remove, these after-treatments are even more necessary to the removal of ammonia nitrogen for example, with complete removal using nitrification and denitrification or simply achieving the nitrification stage, because the ammonia is toxic to a great part of aquatic life, mostly fishes, while the nitrogen in the form of ions nitrate or nitrite is considered less toxic. There are already in the literature some descriptions of how to dimension those units of after-treatment, however, the parameters used are theoretical and based on the pre-existent to sanitary wastewater typically domestic, not having yet a source of experimental data for those parameters. The objective of this paper is to get real data to project the after- treatment of effluents of UASB reactors, using the equation and the methods presented by Ekama, Dold e Marais (1986), based in a pilot system of Activated Sludge, in laboratory level, fed with effluent of an UASB reactor installed on the campus of USP, more precisely in the Hydraulic Technological Center (CTH). This reactor treats the wastewater generated in the communitary restaurant and apartments where the University students live (CRUSP). Like all the aerobic biologic systems of treatment base themselves in the same fractions, the collected data here are really useful to any other aerobic after-treatment of these effluents. The fractions obtained were: fup = 0,15, frb ~0 and fus= 0,2.
29

Estudo da influência do cloreto de sódio na remoção de matéria orgânica, na determinação da DQO e na microbiota em um sistema de tratamento aeróbio por lodos ativados / Study of influence of sodium chloride on the removal of organic matter, the determination of COD and microbiota in an aerobic treatment system by activated sludge

Jorge Augusto de Carvalho Santos 08 October 2010 (has links)
Existem muitos tipos de substâncias orgânicas e inorgânicas que podem apresentar efeito tóxico ou inibidor aos organismos dos sistemas aeróbios de tratamento de efluentes, e entre essas substâncias está o cloreto. Nos efluentes, os cloretos se apresentam na forma de algum tipo de sal, e o mais comum é o cloreto de sódio. O cloreto de sódio pode ser encontrado em vários tipos de efluentes como, por exemplo, efluentes de indústrias alimentícias, petrolíferas, de processamento de couro e no lixiviado de aterros sanitários. Os cloretos podem além de prejudicar a microbiota, interferir no método de determinação da Demanda Química de Oxigênio - DQO e da Demanda Bioquímica de Oxigênio - DBO, que são parâmetros comumente utilizados para controle operacional de estações de tratamento. O presente trabalho teve como objetivo estudar a influência da adição de cloretos em um sistema de tratamento aeróbio por lodos ativados de bancada, que foi avaliado com base na remoção de matéria orgânica e no desenvolvimento e interação da microbiota envolvida. Foi avaliado o efeito tóxico da adição de concentrações de cloreto variando de 0 a 16 g\'CL POT. -\'/L. Os resultados confirmaram que há uma perda significativa de eficiência de remoção de matéria orgânica, principalmente quando a concentração de cloretos é superior a 4 g\'CL POT. -\'/L. Observou-se também que determinadas concentrações de cloretos são tóxicas aos organismos e prejudicam a estrutura dos flocos biológicos. Além disso, concluiu-se que a determinação da DQO pelo método 5220D do Standard Methods for Examination of Water and Wastewater sofre, em alguns casos, a interferência do cloreto e portanto pode não ser o melhor parâmetro para avaliação de eficiência dos sistemas de tratamento que operam sob essa condição. / There are many types of organic and inorganic substances that may have toxic effect on microorganisms of aerobic systems for wastewater treatment, and among these substances is the chloride. In the effluents, the chlorides are in the form of some type of salt, and most common is sodium chloride. Sodium chloride can be found in various types of effluents, for example, effluents from food industries, oil, leather processing and leachate from landfills. The chlorides can also affect the microbiota, interfering with the method of determining the Chemical Oxygen Demand - COD and the Biochemical Oxygen Demand - BOD, which are commonly used parameters for operational control of treatment plants. This work aimed to study the influence of the addition of chlorides in a system of aerobic activated sludge bench, which was evaluated based on the removal of organic matter and the development and interaction of microorganisms involved. We evaluated the toxic effect of adding chloride concentrations ranging 0-16 g\'CL POT. -\' /L. The results confirmed that there is a significant loss of removal efficiency of organic matter, especially when the chloride concentration is more than 4 g\'CL POT. -\'/L. It was also noted that certain concentrations of chloride are toxic to microorganisms and affect the structure of biological flocs. Furthemore, it was concluded that the determination of COD by 5220D method of Standard Methods for Examination of Water and Wastewater suffers, in some cases, interference of chloride and maybe not the better parameter for evaluating efficiency of treatment systems that operate under this condition.
30

Utilização de reatores enzimáticos como unidades de pré-tratamento para sistemas de lodos ativados utilizando esgoto sintético a base de lipídios / Utilization of enzymatic reactors, as units of pre-treatment for activated sludge systems using synthetic wastewater based on lipids

Marcelo Romano Modolo 28 June 2002 (has links)
Sabe-se que as águas residuárias, contendo elevadas concentrações de lipídios, causam problemas às unidades convencionais de tratamento podendo gerar lodo altamente biodegradável e sistemas com baixos rendimentos na remoção da matéria orgânica. Com o intuito de estudar a possibilidade de se obter eficiências maiores de remoção de matéria orgânica no tratamento de águas residuárias com elevados teores de lipídios, empregou-se na presente pesquisa processo alternativo de tratamento denominado de sistema combinado, composto de um reator enzimático (R1) e de um reator de lodos ativados (R2). Visando realizar a pré-hidrólise dos lipídios afluentes, o reator enzimático, contendo a enzima lipase LIPOLASE 100T, imobilizada em suporte de polietileno, foi instalado antecedendo o reator de lodos ativados. Paralelamente, foi construída outra unidade de lodos ativados (Rc) similar a primeira, porém sem o reator enzimático acoplado, denominada sistema de controle, visando possibilitar a comparação dos resultados obtidos. A unidade experimental foi operada durante 94 dias, em regime contínuo com a temperatura em torno de 30ºC. Os reatores de lodos ativados, R2 e Rc, foram operados, cada, com TDH de 8 horas e vazão de 3,4 L/dia. As eficiências médias de remoção de DQO bruta obtidas foram respectivamente de 85% e 79% para os sistemas combinado e de controle. A eficiência média de remoção de óleos e graxas do sistema combinado foi de 91%, enquanto que para o sistema de controle a eficiência média foi de 84%. Assim, os resultados obtidos no presente trabalho, demonstraram que as vantagens obtidas com o emprego do sistema combinado proposto, sob as condições específicas da presente pesquisa, foram significativas. / The wastewaters containing high concentrations of lipids, cause problems to the conventional units of treatment being able to produce highly biodegradable sludge and systems with low organic matter removal. In order to study the possibility of obtaining high efficiencies of organic matter removal in the treatment of wastewater with high contents of lipids, it was used in the present research an alternative procedure of treatment named combined system, composed of an enzymatic reactor (R1) and an activated sludge reactor (R2). In order to achieve the pre-hydrolysis of the affluent lipids, the enzymatic reactor, containing the lipase enzyme LIPOLASE 100T immobilized in polyethylene support, was installed preceding the activated sludge. Parallely, it was built another unit of activated sludge (Rc) similar to the first, but without the enzymatic reactor coupled, named control system, in order to enable the comparisons of the results obtained. The experimental unit was operated during 94 d, in continuous operation, with the temperature around 30°C. The activated sludge reactors, R2 and Rc, were operated, respectively, with hydraulic time residence of 8 h and flow rate of 3,4 L/d. The average efficiencies of removal raw COD obtained were respectively, of 85% and 79% for the combined and control systems. The average efficiency of removal of oil and greases of the combined system was of 91%, while for the control system the average efficiency was of 84%. So, the results obtained in this present work, showed that the advantages obtained with the use of the proposed system, under the specific conditions of the present research, were significant.

Page generated in 0.1077 seconds