• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 26
  • 21
  • 8
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 64
  • 15
  • 11
  • 11
  • 10
  • 9
  • 9
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Retrospektive Untersuchung zu implantatverankerten Ohrepithesen

Guo, Gao 03 May 2005 (has links)
Das Ziel dieser Arbeit war es, das klinische Resultat der implantatverankerten Ohrepithese retrospektiv zu untersuchen. Es wurden die Daten von 46 Patienten erhoben, die von 1992 bis 2003 mit implantatverankerten Ohrepithesen versorgt wurden. Bei 20 Patienten mit 53 Implantaten wurde eine spezielle Nachuntersuchung zur Beurteilung der periimplantären Weichgewebssituation durchgeführt. Zwei objektive klinische Parameter, die Sondierungstiefe und die Sulcus Fluid Flow Rate (SFFR), wurden hierfür angewendet. Die subjektive Beurteilung der Hautreaktionen war durch das Graduierungsystem von Holgers klassifiziert. 24 Patienten wurden mit Hilfe eines einheitlichen Fragebogens über die Zufriedenheit und auf mögliche Beschwerden befragt. Die kongenitalen Ohrmissbildungen (62,5%) waren die häufigsten Indikationen bei dieser Behandlung. 156 Implantate und eine Trägerplatte (Epitec-System®) bei den 46 Patienten inseriert, darunter waren 23 Implantate aus dem EO-System®, sowie 133 aus dem Brånemark-System®. Intraoperative Komplikationen traten bei der Implantatinsertion nicht auf. Die Implantationserfolgsrate liegt bei 100%. Bei 34 Patienten (74%) wurden insgesamt 42-mal Hautreaktionen (Entzündungen, Blutungen, Schwellungen) während der Nachkontrolle registriert. Die durchschnittliche Tragezeit der Ohrepithesen betrug 2,7 Jahre. Periimplantäre Hauttaschen sind in unserer Studie bei allen untersuchten Implantaten beobachtet worden. In der speziellen Nachuntersuchung lag der mittlere Wert der Sondierungstiefe und der SFFR bei 2,1 mm bzw. 1,8 mm. Zwischen beiden Parameter wurde eine starke Korrelation festgestellt: Je tiefer die Sondierungstiefe desto höher waren die Werte der SFFR. Bei 22 Implantaten (41,5%) ergaben sich keine Hautreaktionen. Die Entzündungen wurden nur an vier Implantaten (7,5%) beobachtet. 91,7% der befragten Patienten waren mit ihrer Ohrepithese zufrieden. Anhand unserer Studie, dass die implantatverankerten Ohrepithese heute ausgezeichnete und stabile Langzeitergebnisse erzielt werden können. Die tiefe Hauttasche spricht für ein Zeichen der periimplantären Entzündung und eine Notwendigkeit einer periimplantäreren Hautausdünnung. / The purpose of this study is to retrospectively evaluate the clinical results of the implant-retained auricular prosthesis. The data of 46 patients who were treated between 1992 and 2003 with implant-retained auricular prosthesis were evaluated. 20 patients with 53 implants were re-examined to evaluate the periimplant soft tissue situation with two objective clinical parameters periimplant sulcus probing depth and sulcus-fluid-flow-rate (SFFR). The subjective evalution of skin reactions around the abutments was classified as reported by Holgers. Satisfaction and eventual complications were evaluated in 24 patients by using standardized Questionnaires. Congenital malformation (62.5%) was the most common indications for auricular prostheses. A total of 156 implants and a plate (Epitec-System®) were placed in 46 patients, 23 of which were EO-System®, and 133 were Brånemark-System®. No intraoperative complications were reported during the insertion of implants. The implant survival rate was 100%. 42 times of skin reactions (inflammation, bleeding, swelling) were registered in 34 patients. The average wearing time of the prosthesis was 2.7 year. Skin pockets were found in all of the 53 re-examined implants. The middle value of sulcus probing depth and SFFR was respectively 2.1 mm and 1.8 mm. A strong correlation was found between the two parameter, which suggests that a deeper sulcus always presents a high value of SFFR. No adverse skin reactions was found in 22 implants (41.5%). Severe inflammation was observed in only 4 implants (7.5%). 91,7% of patients were satisfied with their prostheses. From this study it can be concluded that the implant-retained auricular prostheses offer a good and secure perspective for patients. The deep sulcus shows a sign of periimplantitis and a surgical thinning of subcutaneous periimplant soft tissue should be perfomed to eliminate it.
42

Enhancing Health Among Drug Users in Prison / Att befrämja hälsa bland drogmissbrukare i fängelse

Berman, Anne H January 2004 (has links)
Four interrelated studies on drug users in prison are presented within the framework of a proposed model for approaching the enhancement of health for persons that builds on an existential view of prisoners’ needs, as well as the risk management and “good lives” perspectives. Risk management is the major focus in current offender rehabilitation based on research on “what works,” which has shown that focusing treatment on risk factors termed “criminogenic needs,” such as impulsivity, poor family relations and drug abuse, reduces recidivism by 10-15 percentage points. The “good lives” perspective proposes that offender rehabilitation should go beyond risk management and also address non-criminogenic needs such as autonomy, relatedness and competence as foundations for building personally meaningful lives. Study I explores the assessment of drug use problems, and describes the psychometric evaluation of the Drug Use Disorders Identification Test (DUDIT), a newly developed 11-item test for quick screening of drug-related problems. Studies II-IV explore treatment for offenders in prison identified as drug users. Study II is a randomized controlled trial of two auricular acupuncture treatments for men and women in prison, inconclusive with regard to point specificity but showing that participants in both groups reported reduced symptoms of discomfort and improved night-time sleep. Study III evaluates the Reasoning & Rehabilitation program, an internationally widespread cognitive-behavioral program for groups of offenders. Results showed significant pro-social short-term changes in sense of coherence, impulsivity and attitudes towards the criminal justice system, as well as a 25% lower risk of reconviction among program completers compared to matched controls. However, the quasi-experimental nature of the study precludes any certainty regarding program effects; a selection bias whereby more motivated program participants are recruited could explain the findings. Study IV is a pilot project exploring the special needs of a subgroup of drug-using inmates with psychiatric and/or violent co-morbidity. Inmates housed in psychiatric prison units were offered long-term auricular acupuncture treatment. Half of the 22 inmates in the study received treatment twice a week for over eight weeks, and those treated over 25 times had lower psychopharmacological medication levels than untreated controls. Studies I-IV address individual facets of a proposed model for enhancing health among drug users in prison. The health enhancement model approaches offender rehabilitation from perspectives of existential psychology, good lives and risk management. Specific definitions of physical, social, psychological/personal and spiritual needs indicate a framework according to which prison treatment can help drug-using offenders find ways to secure healthy need satisfaction.
43

Estimation of Atrial Electrical Complexity during Atrial Fibrillation by Solving the Inverse Problem of Electrocardiography

Molero Alabau, Rubén 30 October 2023 (has links)
Tesis por compendio / [ES] La fibrilación auricular (FA) es la arritmia más prevalente en el mundo y está asociada con una elevada morbilidad, mortalidad y costes sanitarios. A pesar de los avances en opciones de tratamiento farmacológico y terapia de ablación, el manejo de la FA todavía tiene margen de mejora. La imagen electrocardiográfica (ECGI) se ha destacado como un prometedor método no invasivo para evaluar la electrofisiología cardíaca y guiar las decisiones terapéuticas en casos de fibrilación auricular. No obstante, el ECGI se enfrenta a desafíos como la necesidad de resolver de manera precisa el denominado problema inverso de la electrocardiografía y de optimizar la calidad de las reconstrucciones de ECGI. Además, la integración del ECGI en los procesos clínicos rutinarios sigue siendo un reto, en gran medida debido a los costos que supone la necesidad de imágenes cardíacas. Por ello, los objetivos principales de esta tesis doctoral son impulsar la tecnología ECGI mediante la determinación de sus requisitos técnicos mínimos y la mejora de las metodologías existentes para obtener señales de ECGI precisas. Asimismo, buscamos evaluar la capacidad de ECGI para cuantificar de forma no invasiva la complejidad de la FA. Para lograr estos objetivos, se han llevado a cabo diversos estudios a lo largo de la tesis, desde el perfeccionamiento del ECGI hasta la evaluación de la FA utilizando esta tecnología. En primer lugar, se han estudiado los requisitos geométricos y de señal del problema inverso mediante el estudio de los efectos de la densidad de la malla del torso y la distribución de electrodos en la precisión del ECGI, lo que ha conducido a la identificación del número mínimo de nodos y su distribución en la malla del torso. Además, hemos identificado que para obtener señales de ECGI de alta calidad, es crucial la correcta disposición de los electrodos en la malla del torso reconstruido. Asimismo, se ha definido y evaluado una nueva metodología de ECGI sin necesidad de usar técnicas de imagen cardiaca. Para ello, hemos comparado métricas derivadas del ECGI calculadas con la geometría original del corazón de los pacientes con las métricas medidas en diferentes geometrías cardíacas. Nuestros resultados han mostrado que el ECGI sin necesidad de imágenes cardíacas es efectivo para la correcta cuantificación y localización de los patrones y zonas que mantienen la FA. En paralelo, hemos optimizado la regularización de Tikhonov de orden cero actual y la optimización de la curva L para el cálculo de las señales ECGI, investigando cómo el ruido eléctrico y las incertidumbres geométricas influyen en la regularización. A partir de ello, propusimos un nuevo criterio que realza la precisión de las soluciones de ECGI en escenarios con incertidumbre debido a condiciones de señal no ideales. En segundo lugar, en esta tesis doctoral, se han llevado a cabo múltiples análisis relativos a diferentes metodologías de procesado de señales y obtención métricas derivadas del ECGI con el fin de caracterizar mejor el sustrato cardíaco y la actividad reentrante en las señales de ECGI de pacientes con FA. Con el objetivo de obtener una comprensión más profunda de los mecanismos electrofisiológicos subyacentes a la FA, hemos establecido la estrategia de filtrado óptima para extraer patrones reentrantes específicos del paciente y métricas derivadas de señales ECGI. Además, hemos investigado la reproducibilidad de los mapas de reentradas derivados de las señales de ECGI y hemos encontrado su relación con el éxito de la ablación de venas pulmonares (PVI). Nuestros resultados han mostrado que una mayor reproducibilidad en los patrones reentrantes de FA detectados con ECGI está relacionada con el éxito de la PVI, creando una metodología para estratificar a los pacientes con FA antes de los procedimientos de ablación. / [CA] La fibril·lació auricular (FA) és l'arrítmia més prevalent al món i està associada amb una elevada morbiditat, mortalitat i costos sanitaris. Malgrat els avanços en opcions de tractament farmacològic i teràpies d'ablació, el maneig de la FA encara té marge de millora. La imatge electrocardiogràfica (ECGI) s'ha destacat com un prometedor mètode no invasiu per a avaluar l'electrofisiologia cardíaca i guiar les decisions terapèutiques en casos de fibril·lació auricular. No obstant això, l'ECGI s'enfronta a desafiaments com la necessitat de resoldre de manera precisa el denominat problema invers de la electrocardiografia i d'optimitzar la qualitat de les reconstruccions de ECGI. A més, la integració del ECGI en els processos clínics rutinaris continua sent un repte, en gran manera a causa dels costos que suposa la necessitat d'imatges cardíaques. Per això, els objectius principals d'aquesta tesi doctoral són impulsar la tecnologia de l'ECGI mitjançant la determinació dels seus requisits tècnics mínims i la millora de les metodologies existents per obtenir senyals d'ECGI precises. A més, busquem avaluar la capacitat de l'ECGI per quantificar de forma no invasiva la complexitat de la FA. Per a aconseguir aquests objectius, s'han dut a terme diversos estudis al llarg de la tesi, des del perfeccionament de l'ECGI fins a l'avaluació de la FA utilitzant aquesta tecnologia. En primer lloc, hem estudiat els requisits geomètrics i de senyal del problema invers mitjançant l'estudi dels efectes de la densitat de la malla del tors i la distribució d'elèctrodes en la precisió de l'ECGI, el que ha conduït a la identificació del nombre mínim de nodes i la seva distribució en la malla del tors. A més, hem identificat que per obtindre senyals d'ECGI d'alta qualitat, és crucial la correcta disposició dels elèctrodes en la malla del tors reconstruïda. També s'ha definit i avaluat una nova metodologia d'ECGI sense necessitat d'utilitzar tècniques d'imatge cardíaca. Per a això, hem comparat mètriques derivades de l'ECGI calculades amb la geometria original del cor dels pacients amb les mètriques mesurades en diferents geometries cardíaques. Els nostres resultats han mostrat que l'ECGI sense necessitat d'imatges cardíaques és efectiu per a la correcta quantificació i localització dels patrons i zones que mantenen la FA. Paral·lelament, hem optimitzat la regularització de Tikhonov d'ordre zero actual i l'optimització de la corba L per al càlcul de les senyals d'ECGI, investigant com el soroll elèctric i les incerteses geomètriques influeixen en la regularització. Addicionalment, vam proposar un nou criteri que reforça la precisió de les solucions d'ECGI en escenaris amb incertesa degut a condicions de senyal no ideals. En segon lloc, en aquesta tesi doctoral, s'han dut a terme múltiples anàlisis relatius a diferents metodologies de processament de senyals i obtenció de mètriques derivades de l'ECGI amb l'objectiu de caracteritzar millor el substrat cardíac i l'activitat reentrant en les senyals d'ECGI de pacients amb FA. Amb l'objectiu d'obtindre una comprensió més profunda dels mecanismes electrofisiològics subjacents a la FA, hem establert l'estratègia de filtrat òptima per extreure patrons reentrants específics del pacient i mètriques derivades de senyals ECGI. A més, hem investigat la reproductibilitat dels mapes de reentrades derivats de les senyals d'ECGI i hem trobat la seva relació amb l'èxit de l'ablació de venes pulmonars (PVI). Els nostres resultats han mostrat que una major reproductibilitat en els patrons reentrants de FA detectats amb ECGI està relacionada amb l'èxit de la PVI, creant una metodologia per estratificar els pacients amb FA abans dels procediments d'ablació. / [EN] Atrial fibrillation (AF) is the most prevalent arrhythmia in the world and is associated with significant morbidity, mortality, and healthcare costs. Despite advancements in pharmaceutical treatment alternatives and ablation therapy, AF management remains suboptimal. Electrocardiographic Imaging (ECGI) has emerged as a promising non-invasive method for assessing cardiac electrophysiology and guiding therapeutic decisions in atrial fibrillation. However, ECGI faces challenges in dealing with accurately resolving the ill-posed inverse problem of electrocardiography and optimizing the quality of ECGI reconstructions. Additionally, the integration of ECGI into clinical workflows is still a challenge that is hindered by the associated costs arising from the need for cardiac imaging. For this purpose, the main objectives of this PhD thesis are to advance ECGI technology by determining the minimal technical requirements and refining existing methodologies for acquiring accurate ECGI signals. In addition, we aim to assess the capacity of ECGI for noninvasively quantifying AF complexity. To fulfill these objectives, several studies were developed throughout the thesis, advancing from ECGI enhancement to AF evaluation using ECGI. Firstly, geometric and signal requirements of the inverse problem were addressed by studying the effects of torso mesh density and electrode distribution on ECGI accuracy, leading to the identification of the minimal number of nodes and their distribution on the torso mesh. Besides, we identified that the correct location of the electrodes on the reconstructed torso mesh is critical for the accurate ECGI signal obtention. Additionally, a new methodology of imageless ECGI was defined and assessed by comparing ECGI-derived drivers computed with the original heart geometry of the patients to the drivers measured in different heart geometries. Our results showed the ability of imageless ECGI to the correct quantification and location of atrial fibrillation drivers, validating the use of ECGI without the need for cardiac imaging. Also, the current state of-the-art zero-order Tikhonov regularization and L-curve optimization for computing ECGI signals were improved by investigating the impact of electrical noise and geometrical uncertainties on the regularization. We proposed a new criterion that enhances the accuracy and reliability of ECGI solutions in situations with uncertainty from unfavorable signal conditions. Secondly, in this PhD thesis, several analyses, signal processing methodologies, and ECGIderived metrics were investigated to better characterize the cardiac substrate and reentrant activity in ECGI signals from AF patients. With the objective of obtaining a deeper understanding of the electrophysiological mechanisms underlying AF, we established the optimal filtering strategy to extract patient-specific reentrant patterns and derived metrics in ECGI signals. Furthermore, we investigated the reproducibility of the obtained ECGI-reentrant maps and linked them to the success of PVI ablation. Our results showed that higher reproducibility on AF drivers detected with ECGI is linked with the success of PVI, creating a proof-of-concept mechanism for stratifying AF patients prior to ablation procedures. / This work was supported by: Instituto de Salud Carlos III, and Ministerio de Ciencia e Innovación (supported by FEDER Fondo Europeo de Desarrollo Regional DIDIMO PLEC2021- 007614, ESSENCE PID2020-119364RB-I00, and RYC2018- 024346B-750), EIT Health (Activity code SAVE-COR 220385, EIT Health is supported by EIT, a body of the European Union) and Generalitat Valenciana Conselleria d’Educació, Investigació, Cultura i Esport (ACIF/2020/265 and BEFPI/2021/062). / Molero Alabau, R. (2023). Estimation of Atrial Electrical Complexity during Atrial Fibrillation by Solving the Inverse Problem of Electrocardiography [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/199029 / Compendio
44

The use of human induced pluripotent stem cell-derived atrial cardiomyocytes for studying arrhythmia mechanisms

Casini, Marilù 13 May 2024 (has links)
[ES] Cada año, cientos de miles de nuevos casos en todo el mundo son diagnosticados anualmente con fibrilación auricular, estimándose que aproximadamente 33.5 millones de personas viven con esta compleja enfermedad. Sin embargo, se hizo evidente que la fibrilación auricular es una enfermedad multifacética y progresiva. Por lo tanto, se requiere el desarrollo de nuevos modelos experimentales que recapitulen este complejo mecanismo. Por esta razón, esta tesis ha navegado a través del intrincado panorama del remodelado de la fibrilación auricular desde un punto de vista electrofisiológico, estructural e inmunológico, utilizando un modelo in vitro de cardiomiocitos atriales derivados de células madre pluripotentes inducidas humanas (hiPSC-aCM). El modelo demostró ser capaz de recapitular mecanismos de reentrada, así como remodelados genéticos correlacionados con cambios electrofisiológicos, estructurales e inmunológicos similares a los observados en pacientes con fibrilación auricular, demostrando su valor como modelo para estudiar los mecanismos de iniciación de la arritmia. Además, la tesis exploró enfoques optogenéticos innovadores para la perturbación del potencial de acción en hiPSC-aCM, demostrando su posible uso para la terminación de la arritmia. En conclusión, esta tesis de doctorado realiza una contribución significativa al desarrollo y prueba de un nuevo modelo in vitro de fibrilación auricular en atrios humanos, proporcionando una base sólida para futuras mejoras en los objetivos terapéuticos y medicamentos. / [CA] Cada any, centenars de milers de nous casos a tot el món són diagnosticats anualment amb fibrilació auricular, estimantse que aproximadament 33.5 milions de persones viuen amb aquesta complexa malaltia. No obstant això, es va fer evident que la fibril·lació auricular és una malaltia multifacètica i progressiva. Per tant, es requereix el desenvolupament de nous models experimentals que recapitulen aquest complex mecanisme. Per aquesta raó, aquesta tesi ha navegat a través del intrincat panorama del remodelat de la fibrilació auricular des d'un punt de vista electrofisiològic, estructural i immunològic, utilitzant un model in vitro de cardiomiòcits atrials derivats de cèlules mare pluripotents induïdes humanes (hiPSC-aCM). El model va demostrar ser capaç de recapitular mecanismes de reentrada, així com remodelats genètics correlacionats amb canvis electrofisiològics, estructurals i immunològics similars als observats en pacients amb fibril·lació auricular, demostrant el seu valor com a model per estudiar els mecanismes d'iniciació de l'arítmia. A més, la tesi va explorar enfocs optogenètics innovadors per a la pertorbació del potencial d'acció en hiPSC-aCM, demostrant el seu possible ús per a la terminació de l'arítmia. En conclusió, aquesta tesi de doctorat realitza una contribució significativa al desenvolupament i prova d'un nou model in vitro de fibril·lació auricular en atris humans, proporcionant una base sòlida per a futures millores en els objectius terapèutics i medicaments. / [EN] Each year hundreds of thousands of new cases worldwide are annually diagnosed with atrial fibrillation (AF), estimating that approximately 33.5 million of people worldwide live with this complex disease. However, it became clear that AF is not only a prevalent cardiac arrhythmia but also a multifaceted and progressive one. Thus, the development of new experimental models that recapitulate this complex mechanism is required. For this reason, this thesis has navigated through the intricate landscape of AF remodeling under an electrophysiological, structural and immunological point of view using an in vitro model of human induced pluripotent stem cell-derived atrial cardiomyocytes (hiPSC-aCM). The model showed to be able to recapitulate re-entry mechanisms as well as genetic remodeling correlated to electrophysiological, structural and immunological changes similar to those observed in AF patients, demonstrating its value as model for studying initiation arrhythmia mechanisms. Furthermore, the thesis explored innovative optogenetic approaches for action potential perturbation in hiPSC-aCM, demonstrating their possible use for arrhythmia termination. In conclusion, this PhD thesis makes a significant contribution to the development and testing of a new human atrial in vitro model of AF, providing a strong basis for future improvements of therapeutic target and drugs. / Casini, M. (2024). The use of human induced pluripotent stem cell-derived atrial cardiomyocytes for studying arrhythmia mechanisms [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/204142
45

Surface curvature of pelvic joints from three laser scanners: separating anatomy from measurement error.

Villa, C., Gaudio, D., Cattaneo, C., Buckberry, Jo, Wilson, Andrew S., Lynnerup, N. 16 April 2014 (has links)
Yes / Recent studies have reported that quantifying symphyseal and auricular surfaces curvature changes on 3D models acquired by laser scanners have a potential for age estimation. However, no tests have been carried out to evaluate the repeatability of the results between different laser scanners. 3D models of the two pelvic joints were generated using three laser scanners (Custom, Faro, Minolta). The surface curvature, the surface area and the distance between co-registered meshes were investigated. Close results were found for surface areas (differences between 0.3% and 2.4%) and for distance deviations (average < 20 μm, SD < 200 μm). The curvature values were found to be systematically biased between different laser scanners, but still showing similar trends with increasing phases / scores. Applying a smoothing factor to the 3D models, it was possible to separate anatomy from the measurement error of each instrument, so that similar curvature values could be obtained (p < 0.05) independent of the specific laser scanner. / The full text was made available at the end of the publisher's embargo: 31st March 2016
46

Characterization of the Substrate Modification in Patients Undergoing Catheter Ablation of Atrial Fibrillation

Vraka, Aikaterini 20 January 2023 (has links)
Tesis por compendio / [ES] La fibrilación auricular (FA) es la arritmia cardíaca más común. A pesar de la gran popularidad de la ablación con catéter (AC) como tratamiento principal, todavía hay margen de mejora. Aunque las venas pulmonares (VPs) son los principales focos de FA, muchos sitios pueden contribuir a su propagación, formando el sustrato de la FA (SFA). El mapeo preciso del SFA y el registro de la modificación del SFA, como marcador positivo después de AC, son fundamentales. Los electrocardiogramas (ECG) y los electrogramas (EGM) se reclutan para este propósito. Los EGM se utilizan para detectar candidatos de AC como áreas que provocan o perpetúan la FA. Por lo tanto, el análisis de EGM es una parte indispensable de AC. Con la capacidad de observar las aurículas globalmente, la principal aplicación de los ECG es evaluar la modificación del SFA analizando las ondas f o P. A pesar del extenso análisis de cualquiera de los tipos de registro, existen algunas brechas. La AC no-VP aumenta el tiempo en quirófano, provocando mayores riesgos y costos. En cuanto al análisis de la modificación del SFA, se utilizan varios umbrales para definir una onda P prolongada. El principal objetivo de la presente Tesis es contribuir al esfuerzo de análisis de SFA y de modificación de SFA. Para ello, la presente Tesis se desarrolló bajo dos hipótesis principales. Que la calidad de la información extraída durante el SFA y el análisis de modificación del SFA se puede mejorar mediante la introducción de pasos innovadores. Además, la combinación de análisis de ECG y EGM puede aumentar la resolución del mapeo y revelar nueva información sobre los mecanismos de FA. Para cumplir con el objetivo principal, el análisis se divide en 4 partes, conformando los 4 capítulos del Compendio de articulos. En primer lugar, se reclutó la dimensión de correlación de grano grueso (DCGG). DCGG localizó de manera confiable EGM complejos y la clasificación por tipos de FA arrojó una precisión del 84 %. Luego, se adoptó un análisis alternativo de la onda P, estudiando por separado su primera y su segunda parte, correspondientes a la aurícula derecha (AD) e izquierda (AI). Los resultados indicaron LA como la principal fuente de modificación del SFA y subrayaron la importancia de estudiar partes integrales de ECG. Los hallazgos de este estudio también sugieren la implementación de partes integrales de ondas P como un posible alivio de las discrepancias en los umbrales de ondas P para definir el tejido fibrótico. Posteriormente, se estudió el efecto diferente del aislamiento de la VP izquierda (AVPI) y derecha (AVPD) sobre la modificación del SFA. AVPI fue la parte crítica, siendo la fuente exclusiva de acortamiento de onda P. El análisis de los registros durante la AC también permitió una observación más cercana de las fluctuaciones de la variabilidad de la frecuencia cardíaca (VFC) a lo largo del procedimiento de CA, lo que reveló información sobre el efecto de la energía de radiofrecuencia (RF) en el tejido auricular. La última parte se centró en el seno coronario (SC), una estructura fundamental en el mapeo de FA para aumentar la resolución de la información. Se definieron los canales más y menos robustos durante el ritmo sinusal (RS) y se investigó la utilidad de SC en la evaluación de la modificación del SFA. Aunque CS no proporcionó una imagen global de la alteración del SFA, pudo registrar con mayor sensibilidad las fluctuaciones en la respuesta auricular durante la AC. Los hallazgos presentados en esta Tesis Doctoral ofrecen una perspectiva alternativa sobre la modificación del SFA y contribuyen al esfuerzo general sobre el mapeo de FA y la evaluación del sustrato posterior a la CAAC, abriendo futuras líneas de investigación hacia una resolución más alta y un mapeo más eficiente de los mecanismos desencadenantes de la FA. / [CA] La fibril·lació auricular (FA) és l'arítmia cardíaca més comú. Tot i la gran popularitat de l'ablació amb catèter (AC) com a tractament principal, encara hi ha marge de millora. Tot i que les venes pulmonars (VPs) són els principals focus de FA, molts llocs poden contribuir a la seva propagació, formant el substrat de la FA (SFA). El mapatge precís de l'SFA i el registre de la modificació de l'SFA, com a marcador positiu després d'AC, són fonamentals. Els electrocardiogrames (ECG) i els electrogrames (EGM) es recluten per a aquest propòsit. Els EGM es fan servir per detectar candidats d'AC com a àrees que provoquen o perpetuen la FA. Per tant, lanàlisi dEGM és una part indispensable dAC. Amb la capacitat d'observar les aurícules globalment, la principal aplicació dels ECG és avaluar la modificació de l'SFA analitzant les ones f o P. Tot i l'extensa anàlisi de qualsevol dels tipus de registre, hi ha algunes bretxes. L'AC no-VP augmenta el temps a quiròfan, provocant majors riscos i costos. Pel que fa a l'anàlisi de la modificació de l'SFA, s'utilitzen diversos llindars per definir una ona P perllongada. L'objectiu principal d'aquesta Tesi és contribuir a l'esforç d'anàlisi de SFA i de modificació de SFA. Per això, aquesta Tesi es va desenvolupar sota dues hipòtesis principals. Que la qualitat de la informació extreta durant el SFA i lanàlisi de modificació de lSFA es pot millorar mitjançant la introducció de passos innovadors. A més, la combinació d'anàlisi d'ECG i EGM pot augmentar la resolució del mapatge i revelar informació nova sobre els mecanismes de FA. Per complir amb l'objectiu principal, l'anàlisi es divideix en 4 parts i es conforma els 4 capítols del Compendi d'articles. En primer lloc, es va reclutar la dimensió de correlació de gra gruixut (DCGG). DCGG va localitzar de manera fiable EGM complexos i la classificació per tipus de FA va donar una precisió del 84%. Després, es va adoptar una anàlisi alternativa de l'ona P, estudiant per separat la primera i la segona part corresponents a l'aurícula dreta (AD) i esquerra (AI). Els resultats van indicar LA com la font principal de modificació de l'SFA i van subratllar la importància d'estudiar parts integrals d'ECG. Les troballes d'aquest estudi també suggereixen la implementació de parts integrals d'ones P com a possible alleugeriment de les discrepàncies als llindars d'ones P per definir el teixit fibròtic. Posteriorment, es va estudiar l'efecte diferent de l'aïllament de la VP esquerra (AVPI) i la dreta (AVPD) sobre la modificació de l'SFA. AVPI va ser la part crítica, sent la font exclusiva d'escurçament d'ona P. L'anàlisi dels registres durant l'AC també va permetre una observació més propera de les fluctuacions de la variabilitat de la freqüència cardíaca (VFC) al llarg del procediment de CA , cosa que va revelar informació sobre l'efecte de l'energia de radiofreqüència (RF) en el teixit auricular. L'última part es va centrar al si coronari (SC), una estructura fonamental al mapeig de FA per augmentar la resolució de la informació. Es van definir els canals més i menys robustos durant el ritme sinusal (RS) i es va investigar la utilitat de SC a l'avaluació de la modificació de l'SFA. Tot i que CS no va proporcionar una imatge global de l'alteració de l'SFA, va poder registrar amb més sensibilitat les fluctuacions a la resposta auricular durant l'AC. Les troballes presentades en aquesta Tesi Doctoral ofereixen una perspectiva alternativa sobre la modificació de l'SFA i contribueixen a l'esforç general sobre el mapeig de FA i l'avaluació del substrat posterior a la CAAC, obrint futures línies de recerca cap a una resolució més alta i un mapeig més eficient dels mecanismes desencadenants de la FA. / [EN] Atrial fibrillation (AF) is the commonest cardiac arrhythmia. Despite the high popularity of catheter ablation (CA) as the main treatment, there is still room for improvement. Time spent in AF affects the AF confrontation and evolution, with 1,15% of paroxysmal AF patients progressing to persistent annually. Therefore, from diagnosis to follow-up, every aspect that contributes to the AF confrontation is of utmost importance. Although pulmonary veins (PVs) are the main AF foci, many sites may contribute to the AF propagation, by triggering or sustaining the AF, forming the AF substrate. Precise AF substrate mapping and recording of the AF substrate modification, as a positive marker after CA sessions, are critical. Electrocardiograms (ECGs) and electrograms (EGMs) are vastly recruited for this purpose. EGMs are used to detect candidate CA targets as areas that provoke or perpetuate AF. Hence, EGMs analysis is an indispensable part of the CA procedure. With the ability to observe the atria globally, ECGs' main application is to assess the AF substrate modification by analyzing f- or P-waves from recordings before and after CA. Despite the extensive analysis on either recording types, some gaps exist. Non-PV CA increases the time in operation room, provoking higher risks and costs. Furthermore, whether non-PV CA is beneficial is under dispute. As for the AF substrate modification analysis, various thresholds are used to define a prolonged P-wave, related with poor CA prognostics. The main objective of the present Thesis is to contribute to the effort of AF substrate and AF substrate modification analysis. For this purpose, the present Thesis was developed under two main hypotheses. That the information quality extracted during AF substrate and AF substrate modification analysis can be improved by introducing innovative steps. Also, that combining ECG and EGM analysis can augment the mapping resolution and reveal new information regarding AF mechanisms. To accomplish the main objective, the analysis is split in 4 parts, forming the 4 chapters of the Compendium of publications. Firstly, coarse-grained correlation dimension (CGCD) was recruited. CGCD reliably localized highly complex EGMs and classification by AF types yielded 84% accuracy. Then, an alternative P-wave analysis was suggested, studying separately the first and second P-wave parts, corresponding to the right (RA) and left (LA) atrium. The findings indicated LA as the main AF substrate modification source and underlined the importance of studying integral ECG parts. The findings of this study additionally suggest the implementation of integral P-wave parts as a possible alleviation for the discrepancies in P-wave thresholds to define fibrotic tissue. Afterwards, the different effect of left (LPVI) and right pulmonary vein isolation (RPVI) on the AF substrate modification was studied. LPVI was the critical part, being the exclusive source of P-wave shortening. Analysis of recordings during CA also allowed a closer observation of the heart rate variability (HRV) fluctuations throughout the CA procedure, revealing information on the effect of radiofrequency (RF) energy on the atrial tissue. The last part was focused on coronary sinus (CS), a fundamental structure in AF mapping to increase the information resolution. The most and least robust channels during sinus rhythm (SR) were defined and the utility of CS in AF substrate modification evaluation was investigated. Although CS did not provide a global picture of the AF substrate alteration, it was able to record with higher sensitivity the fluctuations in the atrial response during the application of RF energy. The findings presented in this Doctoral Thesis offer an alternative perspective on the AF substrate modification and contribute to the overall effort on AF mapping and post-CA substrate evaluation, opening future lines of research towards a higher resolution and more efficient mapping of the AF drivers. / Vraka, A. (2022). Characterization of the Substrate Modification in Patients Undergoing Catheter Ablation of Atrial Fibrillation [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/191410 / Compendio
47

An Evaluation of Digital Methods in Reverse Engineering Using Selected Medical Applications

Parrott, Andrew Mark 17 November 2006 (has links)
Student Number : 9710738R - MSc (Eng) dissertation - Faculty of Engineering and the Built Environment / This dissertation investigates the use of digital modeling methods for selected medical applications. The digital methods include the design of a cranial implant, auricular prosthesis and the duplication of an oral prosthesis. The digital process includes imaging, image processing, design and fabrication steps. Three types of imaging used are contact and non-contact measurement systems and CT scanning. The investigation uses a Phantom haptic device for digital design. The implants and prostheses are fabricated using a Thermojet printer and investment casting. Traditional and digital processes are compared using four case studies on selected criteria. The conclusions of the investigation are that a digital process can be used and is equal to or better than traditional methods in prosthesis and implant design.
48

Elaboração de próteses auriculares individualizadas por meio de manufatura apoiada por computador. / Custom auricular prostheses design by computer-aided manufacturing.

Moretto, Emerson Galves 22 November 2016 (has links)
Próteses auriculares tem o objetivo de proporcionar uma maior confiança a pacientes com perdas parciais ou totais da orelha. A aparência realista de uma prótese é fator fundamental para a recuperação psicossocial dos pacientes, pois auxilia na dissimulação da perda. O procedimento convencional de elaboração de próteses auriculares envolve o trabalho de um especialista que utiliza processos manuais para recriar a forma singular de uma orelha. Este é um processo lento, complexo e naturalmente pode ocasionar imperfeições. Este estudo apresenta um procedimento que, a partir de exames de imagem, utiliza técnicas computacionais de reconstrução, espelhamento e inversão de modelos tridimensionais para manufatura aditiva (impressão 3D) de moldes. Os resultados mostram que a prótese elaborada utilizando o processo exibe alto grau de realismo, apresentando 97,8% de similaridade dimensional comparada com a orelha sã do paciente. / Auricular prostheses are intended to provide confidence to patients with partial or total loss of the ear. The realistic appearance of a prosthesis is a key factor for the psychosocial recovery helping in dissimulation of loss. The standard procedure of auricular prosthesis design involves the work of an expert using manual processes to recreate the complex shape of the ear. This slow and complex process can easily lead to imperfections. This study presents a procedure that starting from an image exam uses computational techniques of reconstruction, mirroring and inversion of three-dimensional models for additive manufacturing (3D printing) of molds. The results show that the designed prosthesis using the process has a high level of realism, with 97.8% of similarity compared to the healthy ear of the patient.
49

Elaboração de próteses auriculares individualizadas por meio de manufatura apoiada por computador. / Custom auricular prostheses design by computer-aided manufacturing.

Emerson Galves Moretto 22 November 2016 (has links)
Próteses auriculares tem o objetivo de proporcionar uma maior confiança a pacientes com perdas parciais ou totais da orelha. A aparência realista de uma prótese é fator fundamental para a recuperação psicossocial dos pacientes, pois auxilia na dissimulação da perda. O procedimento convencional de elaboração de próteses auriculares envolve o trabalho de um especialista que utiliza processos manuais para recriar a forma singular de uma orelha. Este é um processo lento, complexo e naturalmente pode ocasionar imperfeições. Este estudo apresenta um procedimento que, a partir de exames de imagem, utiliza técnicas computacionais de reconstrução, espelhamento e inversão de modelos tridimensionais para manufatura aditiva (impressão 3D) de moldes. Os resultados mostram que a prótese elaborada utilizando o processo exibe alto grau de realismo, apresentando 97,8% de similaridade dimensional comparada com a orelha sã do paciente. / Auricular prostheses are intended to provide confidence to patients with partial or total loss of the ear. The realistic appearance of a prosthesis is a key factor for the psychosocial recovery helping in dissimulation of loss. The standard procedure of auricular prosthesis design involves the work of an expert using manual processes to recreate the complex shape of the ear. This slow and complex process can easily lead to imperfections. This study presents a procedure that starting from an image exam uses computational techniques of reconstruction, mirroring and inversion of three-dimensional models for additive manufacturing (3D printing) of molds. The results show that the designed prosthesis using the process has a high level of realism, with 97.8% of similarity compared to the healthy ear of the patient.
50

Characterization and processing of atrial fibrillation episodes by convolutive blind source separation algorithms and nonlinear analysis of spectral features

Vayá Salort, Carlos 28 June 2010 (has links)
Las arritmias supraventriculares, en particular la fibrilación auricular (FA), son las enfermedades cardíacas más comúnmente encontradas en la práctica clínica rutinaria. La prevalencia de la FA es inferior al 1\% en la población menor de 60 años, pero aumenta de manera significativa a partir de los 70 años, acercándose al 10\% en los mayores de 80. El padecimiento de un episodio de FA sostenida, además de estar ligado a una mayor tasa de mortalidad, aumenta la probabilidad de sufrir tromboembolismo, infarto de miocardio y accidentes cerebrovasculares. Por otro lado, los episodios de FA paroxística, aquella que termina de manera espontánea, son los precursores de la FA sostenida, lo que suscita un alto interés entre la comunidad científica por conocer los mecanismos responsables de perpetuar o conducir a la terminación espontánea de los episodios de FA. El análisis del ECG de superficie es la técnica no invasiva más extendida en la diagnosis médica de las patologías cardíacas. Para utilizar el ECG como herramienta de estudio de la FA, se necesita separar la actividad auricular (AA) de las demás señales cardioeléctricas. En este sentido, las técnicas de Separación Ciega de Fuentes (BSS) son capaces de realizar un análisis estadístico multiderivación con el objetivo de recuperar un conjunto de fuentes cardioeléctricas independientes, entre las cuales se encuentra la AA. A la hora de abordar un problema de BSS, se hace necesario considerar un modelo de mezcla de las fuentes lo más ajustado posible a la realidad para poder desarrollar algoritmos matemáticos que lo resuelvan. Un modelo viable es aquel que supone mezclas lineales. Dentro del modelo de mezclas lineales se puede además hacer la restricción de que estas sean instantáneas. Este modelo de mezcla lineal instantánea es el utilizado en el Análisis de Componentes Independientes (ICA). / Vayá Salort, C. (2010). Characterization and processing of atrial fibrillation episodes by convolutive blind source separation algorithms and nonlinear analysis of spectral features [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/8416 / Palancia

Page generated in 0.0663 seconds