• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 70
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 75
  • 33
  • 26
  • 26
  • 24
  • 23
  • 21
  • 21
  • 15
  • 14
  • 14
  • 14
  • 13
  • 13
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Uma análise do desempenho dos estudantes no exame nacional do ensino médio e as contribuições para o ensino-aprendizagem de física / An analysis of student performance in national high school examination and contributions to the physical education-learning

Carlos, Pablo Rafael de Oliveira 15 December 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-18T13:40:02Z No. of bitstreams: 1 pablorafaeldeoliveiracarlos.pdf: 29554334 bytes, checksum: 0246060899d919f9c710cf3521c9644b (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-18T14:01:49Z (GMT) No. of bitstreams: 1 pablorafaeldeoliveiracarlos.pdf: 29554334 bytes, checksum: 0246060899d919f9c710cf3521c9644b (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-18T14:02:00Z (GMT) No. of bitstreams: 1 pablorafaeldeoliveiracarlos.pdf: 29554334 bytes, checksum: 0246060899d919f9c710cf3521c9644b (MD5) / Made available in DSpace on 2017-04-18T14:02:00Z (GMT). No. of bitstreams: 1 pablorafaeldeoliveiracarlos.pdf: 29554334 bytes, checksum: 0246060899d919f9c710cf3521c9644b (MD5) Previous issue date: 2016-12-15 / No presente trabalho são abordados aspectos importantes das avaliações de larga escala, principalmente as avaliações de Física, os tipos, as características e também a elaboração das matrizes de referência para tais avaliações e dos itens que compõem os instrumentos de avaliação. Discutiremos a Taxonomia de Bloom, a Teoria Clássica dos Testes e a Teoria de Resposta ao Item. É feita uma análise sobre o desempenho dos estudantes concluintes do Ensino Médio que participaram do Exame Nacional do Ensino Médio (ENEM) nas edições de 2009 a 2014, para esse objetivo foi utilizado como fonte de dados os microdados do ENEM fornecida pelo INEP. Primeiramente é feita uma breve discussão sobre a base teórica que envolve esse modelo de exame, a Teoria de Resposta ao Item e Teoria Clássica dos Testes. Os alunos foram distribuídos em sete níveis de proficiência, buscou-se uma série de informações estatísticas entre outras medidas psicrométricas relevantes. Esse estudo revelou um baixo desempenho em Física dos estudantes que estão concluindo o Ensino Médio no Brasil, evidenciando a necessidade do acompanhamento do ensino nessa disciplina, para assim possibilitar ações políticas e pedagógicas que busquem melhorar a qualidade do ensino científico, sendo assim as avaliações educacionais mostram-se uma excelente ferramenta. Por fim, iremos discorrer a respeito dos aspectos positivos de se avaliar e como os resultados das avaliações podem ser usados para melhorar as práticas pedagógicas no ensino de Física. O produto educacional desenvolvido nesse trabalho de mestrado foi a construção de um guia de elaboração, revisão e aplicação de instrumentos de avaliação no ensino de Física cuja finalidade é dar subsídios aos professores para desenvolver um olhar crítico sobre essas avaliações, além de auxiliar no tratamento dos dados gerados e na utilização desses dados para desenvolver atividades em sala de aula que busquem potencializar o ensino-aprendizagem em Física. / In this work we address important aspects of large-scale assessments, especially the Physic assessments, the types, characteristics and also the preparation of the reference matrices for such assessments and items that make up the evaluation instruments. We discuss Bloom's Taxonomy, the classical theory of tests and the Item Response Theory. We analyse the performance of graduating high school students who participated in the National High School Exam (ENEM) in the 2009 to 2014 editions, for this purpose we used as a data source ENEM microdata provided by INEP. A brief discussion of the theoretical basis is primarily made involving this test model, item response theory and classical theory of tests. The students were divided into seven levels of proficiency, sought a series of statistical information between other relevant psychometric measures. This study revealed a poor performance in Physics of students that are completing high school in Brazil, highlighting the need for monitoring of teaching this discipline, so as to enable political and pedagogical actions that seek to improve the quality of science education, so the educational assessments show is an excellent tool. Finally, we will discuss the positive aspects of assessing and how the results of the evaluations can be used to improve teaching practices in teaching physics. The educational product developed in this master's work was the construction of a preparation guide, review and application of assessment tools in teaching physics whose purpose is to assist teachers to develop a critical eye on these assessments, to help in the treatment of the data generated and to use these data to develop activities in the classroom that seek to enhance the teaching and learning in physics.
72

"Avaliação dos resultados a médio prazo da ablação cirúrgica por radiofreqüência da fibrilação atrial permanente em pacientes portadores de valvopatia mitral reumática" / Mid-term results of the maze procedure using radiofrequency ablation in patients with permanent atrial fibrillation and rheumatic mitral valve disease

Abreu Filho, Carlos Alberto Cordeiro de 21 June 2005 (has links)
A ablação cirúrgica por radiofreqüência (RF) é uma nova técnica para tratar a fibrilação atrial (FA) permanente. O objetivo deste estudo é avaliar a eficácia da ablação cirúrgica por RF da FA permanente em pacientes com valvopatia mitral reumática (VMR). Entre Fevereiro de 2002 e Abril de 2003, 70 pacientes com FA permanente e VMR foram submetidos à operação da valva mitral associada à ablação por RF da FA (Grupo A); ou à operação da valva mitral isolada (Grupo B). No seguimento pós-operatório foram avaliados: a reversão para o ritmo sinusal (RS) e a contratilidade atrial. Após 12 meses de seguimento, os índices de reversão para o RS e de restabelecimento da contratilidade atrial foram significativamente superiores no Grupo A. A ablação cirúrgica por RF é eficaz para o tratamento da FA permanente em pacientes com VMR / Radiofrequency ablation is a new surgical technique to treat permanent atrial fibrillation. The aim of this study was to evaluate the effectiveness of the (RF) ablation for the treatment of permanent AF in patients with rheumatic mitral valve (MV) disease. Between February 2002 and April 2003, 70 patients with permanent AF and rheumatic MV disease were assigned to undergo a MV surgery associated with RF ablation (Group A), or MV surgery alone (Group B). After 12 months of follow-up, the cumulative rates of sinus rhythm conversion and atrial transport function restoration were higher in Group A.The RF ablation is effective for treating permanent AF associated with rheumatic MV disease
73

Análise dos resultados imediatos e tardios do tratamento percutâneo da coartação da aorta em adolescentes e adultos: comparação entre balões e stents / Analysis of the immediate and late results of percutaneous treatment of coarctation of the aorta in adolescents and adults: comparison between balloons and stents

Pedra, Carlos Augusto Cardoso 05 July 2004 (has links)
Mais informações são necessárias para definir se o tratamento percutâneo da coartação da aorta com stents é superior à angioplastia com cateter-balão. De julho de 2000 a maio de 2003, 21 adolescentes e adultos com coartação da aorta focal e média de idade de 24 anos (DP 11 anos) foram submetidos, consecutivamente, a implante de stents (grupo 1). Os resultados foram comparados com os obtidos em um grupo histórico de 15 pacientes com média de idade de 18 anos (DP 10 anos) (p = 0,103) submetidos a angioplastia (grupo 2) nos últimos 18 anos. Após o procedimento, a redução do gradiente sistólico foi maior (99% [DP 2%] versus 87% [DP 17%]; p = 0,015), o gradiente residual foi menor (0,4 mmHg [DP 1,4 mmHg] versus 5,9 mmHg [DP 7,9 mmHg]; p = 0,019), o ganho no local da coartação foi maior (333% [DP 172%] \"versus\" 190% [DP 104%]; p = 0,007) e o diâmetro da coartação foi maior (16,9 mm [DP 2,9 mm] versus 12,9 mm [DP 3,2 mm]; p < 0,001) no grupo 1. Alterações da parede da aorta, incluindo dissecções, abaulamentos e aneurismas, foram observadas em oito pacientes do grupo 2 (53%) e em um do grupo 1 (7%) (p < 0,001). Não houve complicações maiores. Cateterismo (n = 33) ou ressonância magnética (n = 2) de controle foram realizados em seguimento mediano de um ano para o grupo 1 e um ano e meio para o grupo 2 (p = 0,005). A redução do gradiente sistólico persistiu em ambos os grupos; entretanto, gradientes tardios mais altos foram observados no grupo 2 (mediana de 0 mmHg para o grupo 1 versus 3 mmHg para o grupo 2; p = 0,014). Não houve perdas no diâmetro da coartação no grupo 1 e houve ganho tardio no grupo 2 (16,7 mm [DP 2,9 mm] versus 14,6 mm [DP 3,9 mm]; p = 0,075). No grupo 1, dois pacientes necessitaram de novo implante de stent em decorrência da formação de aneurisma ou fratura da malha do stent. No grupo 2, as anormalidades da parede aórtica não progrediram e um paciente necessitou de redilatação em decorrência da recoartação. A pressão arterial sistêmica foi semelhante em ambos os grupos durante o seguimento (sistólica: 126 mmHg [DP 12 mmHg] no grupo 1 versus 120 mmHg [DP 15 mmHg] no grupo 2; diastólica: 81 mmHg [DP 11 mmHg] no grupo 1 versus 80 mmHg [DP 10 mmHg] no grupo 2; p = 0,149 e p = 0,975, respectivamente). Apesar de os desfechos clínicos terem sido satisfatórios e similares com ambas as técnicas, o uso de stents propiciou resultados mais previsíveis e uniformes para alívio da estenose, minimizando também o risco de desenvolvimento de alterações da parede da aorta. / More information is needed to define whether stenting is superior to balloon angioplasty for coarctation of the aorta. From July/2000 to May/2003, 21 adolescents and adults with discrete coarctation underwent consecutive stent implantation at a mean age of 24 years (SD 11 years) (group 1). The results were compared to those achieved by balloon angioplasty performed in the last 18 years in a historical group of 15 patients at a mean age of 18 years (SD 10 years) (p = 0.103) (group 2). After the procedure, systolic gradient reduction was higher (99% [SD 2%] vs. 87% [SD 17%]; p = 0.015), residual gradients lower (0.4 mmHg [SD 1.4 mmHg] vs. 5.9 mmHg [SD 7.9 mmHg); p = 0.019), gain at the coarctation site higher (333% [SD 172%] vs. 190% [SD 104%]; p = 0.007) and coarctation diameter larger (16.9 mm [SD 2.9 mm] vs.12.9 mm [SD 3.2 mm]; p < 0.001) in group 1. Aortic wall abnormalities, including dissections, bulges and aneurysms, were observed in eight patients in group 2 (53%) and in one in group 1 (7%) (p < 0.001). There was no major complication. Repeat catheterization (n = 33) or magnetic resonance imaging (n = 2) was performed at a median follow-up of 1.0 year for group 1 and 1.5 year for group 2 (p = 0.005). Gradient reduction persisted in both groups, although higher late gradients were observed in group 2 (median of 0 mmHg for group 1 vs. 3 mmHg for group 2; p = 0.014). There was no late loss in the coarctation diameter in group 1 and there was a late gain in group 2 (16.7 mm [SD 2.9 mm] for group 1 vs. 14.6 mm [SD 3.9 mm] for group 2; p = 0.075). Two patients required late stenting due to aneurysm formation or stent fracture in group 1. Aortic wall abnormalities did not progress and one patient required redilation due to recoarctation in group 2. Blood pressure was similar in both groups at follow-up (systolic: 126 mmHg [SD 12 mmHg] in group 1 vs. 120 mmHg [SD 15 mmHg] in group 2; diastolic: 81 mmHg [SD 11 mmHg] in group 1 vs. 80 mmHg [SD 10 mmHg] in group 2; p = 0.149 and p = 0.975, respectively). Although satisfactory and similar clinical outcomes were observed with both techniques, the use of stents yielded more predictable and uniform results for stenosis relief, also minimizing the risk of developing aortic wall abnormalities.
74

"Avaliação dos resultados a médio prazo da ablação cirúrgica por radiofreqüência da fibrilação atrial permanente em pacientes portadores de valvopatia mitral reumática" / Mid-term results of the maze procedure using radiofrequency ablation in patients with permanent atrial fibrillation and rheumatic mitral valve disease

Carlos Alberto Cordeiro de Abreu Filho 21 June 2005 (has links)
A ablação cirúrgica por radiofreqüência (RF) é uma nova técnica para tratar a fibrilação atrial (FA) permanente. O objetivo deste estudo é avaliar a eficácia da ablação cirúrgica por RF da FA permanente em pacientes com valvopatia mitral reumática (VMR). Entre Fevereiro de 2002 e Abril de 2003, 70 pacientes com FA permanente e VMR foram submetidos à operação da valva mitral associada à ablação por RF da FA (Grupo A); ou à operação da valva mitral isolada (Grupo B). No seguimento pós-operatório foram avaliados: a reversão para o ritmo sinusal (RS) e a contratilidade atrial. Após 12 meses de seguimento, os índices de reversão para o RS e de restabelecimento da contratilidade atrial foram significativamente superiores no Grupo A. A ablação cirúrgica por RF é eficaz para o tratamento da FA permanente em pacientes com VMR / Radiofrequency ablation is a new surgical technique to treat permanent atrial fibrillation. The aim of this study was to evaluate the effectiveness of the (RF) ablation for the treatment of permanent AF in patients with rheumatic mitral valve (MV) disease. Between February 2002 and April 2003, 70 patients with permanent AF and rheumatic MV disease were assigned to undergo a MV surgery associated with RF ablation (Group A), or MV surgery alone (Group B). After 12 months of follow-up, the cumulative rates of sinus rhythm conversion and atrial transport function restoration were higher in Group A.The RF ablation is effective for treating permanent AF associated with rheumatic MV disease
75

Análise dos resultados imediatos e tardios do tratamento percutâneo da coartação da aorta em adolescentes e adultos: comparação entre balões e stents / Analysis of the immediate and late results of percutaneous treatment of coarctation of the aorta in adolescents and adults: comparison between balloons and stents

Carlos Augusto Cardoso Pedra 05 July 2004 (has links)
Mais informações são necessárias para definir se o tratamento percutâneo da coartação da aorta com stents é superior à angioplastia com cateter-balão. De julho de 2000 a maio de 2003, 21 adolescentes e adultos com coartação da aorta focal e média de idade de 24 anos (DP 11 anos) foram submetidos, consecutivamente, a implante de stents (grupo 1). Os resultados foram comparados com os obtidos em um grupo histórico de 15 pacientes com média de idade de 18 anos (DP 10 anos) (p = 0,103) submetidos a angioplastia (grupo 2) nos últimos 18 anos. Após o procedimento, a redução do gradiente sistólico foi maior (99% [DP 2%] versus 87% [DP 17%]; p = 0,015), o gradiente residual foi menor (0,4 mmHg [DP 1,4 mmHg] versus 5,9 mmHg [DP 7,9 mmHg]; p = 0,019), o ganho no local da coartação foi maior (333% [DP 172%] \"versus\" 190% [DP 104%]; p = 0,007) e o diâmetro da coartação foi maior (16,9 mm [DP 2,9 mm] versus 12,9 mm [DP 3,2 mm]; p < 0,001) no grupo 1. Alterações da parede da aorta, incluindo dissecções, abaulamentos e aneurismas, foram observadas em oito pacientes do grupo 2 (53%) e em um do grupo 1 (7%) (p < 0,001). Não houve complicações maiores. Cateterismo (n = 33) ou ressonância magnética (n = 2) de controle foram realizados em seguimento mediano de um ano para o grupo 1 e um ano e meio para o grupo 2 (p = 0,005). A redução do gradiente sistólico persistiu em ambos os grupos; entretanto, gradientes tardios mais altos foram observados no grupo 2 (mediana de 0 mmHg para o grupo 1 versus 3 mmHg para o grupo 2; p = 0,014). Não houve perdas no diâmetro da coartação no grupo 1 e houve ganho tardio no grupo 2 (16,7 mm [DP 2,9 mm] versus 14,6 mm [DP 3,9 mm]; p = 0,075). No grupo 1, dois pacientes necessitaram de novo implante de stent em decorrência da formação de aneurisma ou fratura da malha do stent. No grupo 2, as anormalidades da parede aórtica não progrediram e um paciente necessitou de redilatação em decorrência da recoartação. A pressão arterial sistêmica foi semelhante em ambos os grupos durante o seguimento (sistólica: 126 mmHg [DP 12 mmHg] no grupo 1 versus 120 mmHg [DP 15 mmHg] no grupo 2; diastólica: 81 mmHg [DP 11 mmHg] no grupo 1 versus 80 mmHg [DP 10 mmHg] no grupo 2; p = 0,149 e p = 0,975, respectivamente). Apesar de os desfechos clínicos terem sido satisfatórios e similares com ambas as técnicas, o uso de stents propiciou resultados mais previsíveis e uniformes para alívio da estenose, minimizando também o risco de desenvolvimento de alterações da parede da aorta. / More information is needed to define whether stenting is superior to balloon angioplasty for coarctation of the aorta. From July/2000 to May/2003, 21 adolescents and adults with discrete coarctation underwent consecutive stent implantation at a mean age of 24 years (SD 11 years) (group 1). The results were compared to those achieved by balloon angioplasty performed in the last 18 years in a historical group of 15 patients at a mean age of 18 years (SD 10 years) (p = 0.103) (group 2). After the procedure, systolic gradient reduction was higher (99% [SD 2%] vs. 87% [SD 17%]; p = 0.015), residual gradients lower (0.4 mmHg [SD 1.4 mmHg] vs. 5.9 mmHg [SD 7.9 mmHg); p = 0.019), gain at the coarctation site higher (333% [SD 172%] vs. 190% [SD 104%]; p = 0.007) and coarctation diameter larger (16.9 mm [SD 2.9 mm] vs.12.9 mm [SD 3.2 mm]; p < 0.001) in group 1. Aortic wall abnormalities, including dissections, bulges and aneurysms, were observed in eight patients in group 2 (53%) and in one in group 1 (7%) (p < 0.001). There was no major complication. Repeat catheterization (n = 33) or magnetic resonance imaging (n = 2) was performed at a median follow-up of 1.0 year for group 1 and 1.5 year for group 2 (p = 0.005). Gradient reduction persisted in both groups, although higher late gradients were observed in group 2 (median of 0 mmHg for group 1 vs. 3 mmHg for group 2; p = 0.014). There was no late loss in the coarctation diameter in group 1 and there was a late gain in group 2 (16.7 mm [SD 2.9 mm] for group 1 vs. 14.6 mm [SD 3.9 mm] for group 2; p = 0.075). Two patients required late stenting due to aneurysm formation or stent fracture in group 1. Aortic wall abnormalities did not progress and one patient required redilation due to recoarctation in group 2. Blood pressure was similar in both groups at follow-up (systolic: 126 mmHg [SD 12 mmHg] in group 1 vs. 120 mmHg [SD 15 mmHg] in group 2; diastolic: 81 mmHg [SD 11 mmHg] in group 1 vs. 80 mmHg [SD 10 mmHg] in group 2; p = 0.149 and p = 0.975, respectively). Although satisfactory and similar clinical outcomes were observed with both techniques, the use of stents yielded more predictable and uniform results for stenosis relief, also minimizing the risk of developing aortic wall abnormalities.

Page generated in 0.095 seconds