• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 169
  • 5
  • 1
  • Tagged with
  • 175
  • 139
  • 87
  • 53
  • 47
  • 45
  • 42
  • 41
  • 38
  • 34
  • 30
  • 29
  • 28
  • 27
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Influência do tipo de impelidor sobre o desempenho do reator anaeróbio em batelada seqüencial com biomassa granulada tratando esgoto sintético / Influence of the impeller type on the performance of the anaerobic sequencing batch reactor with granulated biomass treating synthetic wastewater

Michelan, Rogério 10 February 2006 (has links)
Em um reator de fundo redondo e volume útil de 5 L tratando esgoto sintético com carga orgânica de 800 mgDQO.'L POT.-1' com biomassa granulada a influência do tipo de escoamento e velocidade rotacional foi investigada com o uso de cinco impelidores sendo eles turbina e pá de seis pás planas verticais, turbina e pá de seis pás planas inclinadas 45 graus e hélice, comumente aplicados em processos biológicos. Foi também investigada a viabilidade de implementação de tubo de tiragem ao reator em conjunto com os impelidores tipo hélice e tipo pá de pás planas inclinadas alternadamente, com vistas a melhorar a mistura e conseqüente transferência de massa no meio reacional. Os resultados mostram que a alteração do tipo de impelidor e as variações da velocidade rotacional não exerceram influência significativa sobre a estabilidade e desempenho dos sistemas estudados. Entretanto a análise das constantes do modelo cinético de primeira ordem mostrou que a alteração na velocidade rotacional exerceu influência de aumento dos valores das constantes, demonstrando com isto que o aumento da velocidade rotacional melhora a transferência de massa sólido-líquido no meio reacional. A análise das constantes cinéticas também demonstrou que a promoção de escoamento axial em reatores agitados mecanicamente é preferível ao escoamento radial quando comparados os impelidores tipo pá de pás planas verticais e de pás planas inclinadas. A presença do tubo de tiragem demonstrou incrementar significativamente a transferência de massa, através do aumento dos valores numéricos das constantes utilizadas no ajuste do modelo cinético de primeira ordem aos valores experimentais. A potência consumida foi inferior a 1,6.'10 POT.-3' HP/'M POT.3' com rotações abaixo de 200 rpm e os impelidores axiais consumiram 75% a menos de potência do que os radiais / The effect of flow type and rotor speed were investigated in a round-bottom reactor with 5 L useful volume containing granular biomass and treating synthetic wastewater with organic load of 800 mgCOD.'L POT.-1'. Five impellers have been used to this end, namely: turbine and paddle with six-vertical-flat blade, turbine and paddle with six-45 degrees-inclined-flat-blade and helix, commonly used in biological processes. Utilization of a draft tube together with the helix and six-alternately-inclined-flat-blade impellers was also assessed as a means to improve mixing and consequently mass transfer in the reaction medium. Results showed that altering impeller type and variation in rotor speed did not exert significant effect on the stability and performance of the investigated systems. However, analysis of the first order kinetic model constants showed that alteration in rotor speed resulted in increase in the values of the constants, demonstrating that increase in rotor speed improves solid-liquid mass transfer in the reaction medium. Analysis of the kinetic constants also showed that axial flow in mechanically stirred reactors is preferable over radial flow when the vertical flat blade impeller is compared to the inclined flat blade impeller. The presence of the draft tube showed significant improvement in mass transfer, which could be seen by the increase in the values of the constants used in the fit of the first order kinetic model to the experimental values. The power consumed was less than 1.6.'10 POT.-3' HP/'M POT.3' at rotor frequency below 200 rpm and the axial impellers consumed 75% less power than the radial ones
92

Pós-tratamento por lodos ativados de efluente de um reator anaeróbio compartimentado no tratamento de esgoto sanitário / Post-treatment by activated sludge of anaerobic baffled reactor effluent in the treatment of sanitary sewage

Coletti, Fábio José 15 December 1997 (has links)
Estudou-se nesta pesquisa o processo de lodos ativados para pós-tratamento do efluente proveniente de um reator anaeróbio compartimentado, que recebe esgoto sanitário. Isso se deu em vários ensaios em sistema descontínuo (\"batch\'\') para avaliar a biodegradabilidade dessa água residuária e em um ensaio em sistema contínuo com finalidade de melhorar a qualidade do efluente final e determinar os coeficientes cinéticos, os parâmetros a\' e b \', a taxa de utilização de oxigênio e o coeficiente &#945. Também realizaram-se ensaios hidrodinâmicos para verificação do tipo de reator utilizado. A pesquisa desenvolveu-se com base em uma célula de aeração, em escala de laboratório, composta por quatro câmaras (reatores) que possuíam tanque de aeração e decantador secundário justapostos, separados por uma cortina fixa. Não houve controle de temperatura nos dois sistemas utilizados. No ensaio em sistema contínuo quatro reatores foram operados simultaneamente com as respectivas idades do lodo de 5, 10, 15 e 20 dias durante 35 dias. O tempo de detenção hidráulico foi mantido próximo de 8 horas. Nesse ensaio os reatores quando se encontravam estabilizados dinamicamente, apresentaram remoção superior a 95% para DBO bruta, 90% para DBO filtrada, 87% para DQO bruta, 80% para DQO filtrada e 95% para SST. Mesmo não sendo realizado processo adicional para remoção de nutrientes, os reatores, após a estabilização dinâmica, apresentaram remoção de fosfato de até 28% e de nitrogênio amoniacal até níveis de não serem detectados pelos métodos de análises utilizados. Os ensaios hidrodinâmicos mostraram que os reatores são do tipo mistura completa. / In this work the activated sludge process for post-treatment of effluent anaerobic baffled reactor which receives sanitary sewage was studied. This was established during various experiments in batch system to evaluate the biodegradable of this wastewater and also in an experiment of continuous system aiming to improve the quality of the final effluent and to determine the kinetic coefficients, the a\' and b\' parameters, the oxygen uptake rate and the &#945 coefficient. Hydrodynamic tests to verify the type of reactor used in this research were also perfonned. The work was developed and based on an aeration cell bench-scale, composed of four chambers (reactors) which had an aeration tank and a secondary settling tank in the same chamber, separated by a fixed baffle. Temperature control was not used in both systems. In the experiment of continuous system, four reactors were simultaneously operated with sludge age of 5, 10, 15 and 20 days during 35 days. The hidraulic retention time was maintained at around 8 hours. When the reactors were dynamically stabilized, they showed an average removal superior to 95% for BOD (biochemical oxygen demand), 90% for filtrated BOD, 87% for COD (chemical oxygen demand), 80% for filtrated COD and 95% for TSS (total suspended solids). Without additional process of nutrient removal, after the dynamic stabilization the reactors presented up to 28% of total phosphate removal and ammonia nitrogen up to levels of not being detected by the analyses methods used. The hydrodynamic tests showed that the reactors are of the complete-mix type.
93

Influência da carga orgânica e do tempo de enchimento sobre o desempenho do reator anaeróbio em batelada seqüencial com biomassa granulada tratando soro de queijo / Effect of organic load and fill time on stability and efficiency of an ASBR containing granular biomass treating cheese whey

Zimmer, Thiago Ruiz 10 February 2006 (has links)
Avaliou-se a influência da carga orgânica volumétrica (COV) aplicada e do tempo de enchimento sobre a estabilidade e a eficiência do ASBR com biomassa granulada, operado em batelada e batelada alimentada seqüenciais, tratando soro de queijo diluído. Os ensaios foram realizados a 30 'graus' C com volume total de meio de 5,0 litros e tempo de ciclo de 8 horas. Na primeira etapa realizou-se a operação em batelada com tempo de enchimento ('T IND.alim') de 10 min e freqüência de agitação de 150 rpm. A cada ciclo foram alimentados 2,0 litros de meio com concentração afluente ('C IND.AF') de 1000, 2000, 4000 e 6000 mg/L, em termos de DQO. A suplementação de alcalinidade foi gradualmente otimizada partindo-se da proporção de 1 a 0,25 da razão 'NA'H'CO IND.3'/DQO. Nestas condições foi possível operar o reator com estabilidade a COV aplicada de 4,8 g/L.d , com suplementação de alcalinidade de 25% e eficiência em remoção de matéria orgânica de 96,0% e 98,4% em termos de DQO filtrada e total, respectivamente. Na segunda etapa devido a problemas operacionais desenvolveram-se dispositivos para assegurar a retenção da biomassa a fim de viabilizar a operação em batelada alimentada. Os dispositivos testados foram ASBR híbrido, sistema de agitação com 2 impelidores, hélice e pá-inclinada (a) e hélice e turbina inclinada (b). A solução utilizada foi hélice e turbina inclinada. Para essa configuração, diminuiu-se a freqüência de agitação para 75 rpm e reduziu-se o volume de biomassa para 1,0 L. Dessa forma foi possível avaliar a influência das estratégias de alimentação ('T IND.alim') de 360, 180 e 10 minutos a COV aplicada constante de 2,4 g/L.d, para 'C IND.AF' de 4000 mg/L e 'V IND.alim' de 1,0 L e para 'C IND.AF' de 8000 mg/L e 'V IND.alim' de 0,5 L. Para a 'C IND.AF' de 4000 mg/L o aumento de 'T IND.alim' resultou em diminuição da eficiência, em termos de DQO solúvel, sendo de 97,8 , 96,7 e 94,5% para os 'T IND.alim' de 10, 180 e 360 minutos, respectivamente. Para a 'C IND.AF' de 8000 mg/L o aumento do 'T IND.alim' resultou em menores valores de DQO total no efluente / The effect of volumetric organic load (VOL) and fill time on the stability and efficiency of an ASBR was assessed. The ASBR containing granular biomass was operated in batch and fed-batch mode and treated diluted cheese whey. Assays were performed at 30 'degrees' C with total medium volume of 5.0 liters and 8-h cycle lengths. In a first stage the reactor was operated batch-wise with fill time ('T IND.feed') of 10 min and agitation frequency of 150 rpm. At each cycle 2.0 liters of medium were fed at influent concentration ('C IND.infl') of 1000, 2000, 4000 and 6000 mg/L, in terms of COD. Alkalinity supplementation was gradually optimized from 100% to 25% of 'NA'H'CO IND.3'/COD ratio. At these conditions the reactor attained stability at applied VOL of 4.8 g/L.d, alkalinity supplementation of 25% and organic matter removal efficiency of 96.0% and 98.4% in terms of soluble and total COD, respectively. In a second stage due to operational problems devices were developed to assure biomass retention and hence make fed-batch operation feasible. The tested devices included hybrid ASBR, agitation system with two impellers: helix and inclined blade impeller (a) and helix and inclined turbine impeller (b). The system chosen was the helix and inclined turbine. With this configuration agitation frequency and biomass volume were reduced to 75 rpm and 1.0 L, respectively. This way, it was possible to assess feed strategies ('T IND.feed') of 360, 180 and 10 minutes at constant applied VOL of 2.4 g/L.d, for 'C IND.infl' of 4000 mg/L at 'V IND.feed' of 1.0 L and for 'C IND.infl' of 8000 mg/L at 'V IND.feed' of 0.5 L. At 'C IND.infl' of 4000 mg/L increase in 'T IND.feed' resulted in decrease in efficiency in terms of soluble COD, which amounted to 97.8, 96.7 and 94.5% for 'T IND.feed' of 10, 180 and 360 minutes, respectively. At 'C IND.infl' of 8000 mg/L the increase in 'T IND.feed' resulted in lower values for COD effluent
94

Estratégias em fluxo para a determinação de acidez, sulfato e cloreto em etanol hidratado combustível / Flow-based strategies for the determination of acidity, sulfate and chloride in hydrous ethanol fuel

Lima, Manoel de Jesus de Aquino 26 April 2019 (has links)
Acidez, sulfato e cloreto são constantemente relacionados ao potencial corrosivo do etanol hidratado combustível (EHC), pois mesmo em baixas concentrações podem induzir processos que danificam dutos de transporte e peças dos veículos. Em vista dessa problemática, as agências reguladoras estabeleceram limites máximos para estes constituintes a serem determinados por titulação, no caso da acidez, e por cromatografia de íons para cloreto e sulfato. Os procedimentos propostos no presente trabalho tiveram como objetivo apresentar alternativas de baixo custo, instrumentação simples, pouca influência do analista (automação das etapas) e baixa geração de efluentes. Para a avaliação da acidez, foi construído um titulador automático, explorando um algoritmo de procura binária em um sistema de análises químicas em fluxo baseado em multicomutação. Sob condições otimizadas, o sistema foi capaz de titular amostras de etanol diluídas a 50% (v/v), gerando cerca de 11,5 mL de efluente por determinação, com coeficiente de variação < 1,0% e frequência de análises > 10 h-1. Além disso, o sistema não necessitou de calibração, fazendo com que todas as etapas fossem realizadas automaticamente. Para as determinações de sulfato e de cloreto, foram montados módulos de análises baseados em fluxo-batelada com detecção espectrofotométrica. Os analitos foram determinados sem etapas de preparo de amostra. Para realizar a determinação indireta do sulfato, foi empregada a reação de deslocamento dos íons bário do complexo dimetilsulfonazo III de bário (DMS-Ba+), promovido pelos íons sulfato; para a determinação de cloreto, foi explorado o efeito dos íons cloreto na fotogeração (UV) de nanopartículas de prata (Ag-NPs). Para sulfato e cloreto, as faixas lineares de resposta, limites de detecção (95%) e coeficientes de variação foram: 0,1 - 1,5 mg L-1 e 0,05 - 0,8 mg L-1; 48 e 12 µg L-1 e 1,0% e 2,2%, respectivamente. Na determinação de sulfato e cloreto, as frequências de análises foram de 35 e 30 h-1, respectivamente; com geração de efluentes < 5 mL por determinação em ambos os procedimentos. Todos os procedimentos desenvolvidos atendem aos limites estabelecidos pela agência reguladora brasileira, e os resultados obtidos foram comparados com os procedimentos oficiais, não havendo diferença significativa entre métodos, ao nível de 95% de probabilidade / Acidity, sulfate and chloride are often related to the hydrous ethanol fuel (HEF) corrosive potential, as even at low concentrations they may induce processes deleterious to transportation ducts and vehycle components. Thus, the regulatory agencies established maximum limits for these constituents to be determined by titration in the case of acidity and by chromatography of ions for chloride and sulfate. The procedures herein proposed aimed at to present alternatives of low cost, simple instrumentation, little influence of the analyst (automation of the stages) and low generation of effluents. For acidity evaluation, an automatic titrator exploiting a binary search algorithm in a analytical flow system based on multicommutation was built up. Under optimized conditions, the system was able of titrating ethanol samples diluted to 50% (v/v), generating about 11.5 mL of effluent per determination, with coefficient of variation <1.0% and sample throughput > 10 h-1. Moreover, the flow system did not require calibration, and all steps were automatically performed. For sulfate and chloride determinations, flow-batch analytical systems with spectrophotometric detection were set up, allowing the analytes to be determined without sample preparation steps. For the indirect determination of sulfate, the reaction of displacement of the barium ions from its dimethylsulfonazo III complex (DMS-Ba+) promoted by the sulfate ions was used; for the determination of chloride, the effect of this analyte on the photo-generation (UV) of silver nanoparticles (Ag-NPs) was exploited. For sulfate and chloride, linear response ranges, detection limits (95% confidence level) and coefficients of variation were: 0.1 - 1.5 and 0.05 - 0.8 mg L-1; 48 and 12 ?g L-1, and 1.0 and 2.2%, respectively. In the sulfate and chloride determinations, the analytical frequency were 35 and 30 h-1, respectively, with effluents generation of < 5 mL per determination for both procedures. The developed procedures meet the limits established by the Brazilian regulatory agency, and results obtained were compared with the official procedures, and no significant differences between methods at the 95% probability level were found
95

Degradação anaeróbia de tolueno em reatores em batelada / not available

Silva, Edmar Delegá da 13 February 2004 (has links)
O presente trabalho avaliou a degradação anaeróbia de tolueno por Bactérias Redutoras de Sulfato (BRS), utilizando como inóculo lodo anaeróbio proveniente de reator UASB. Os ensaios foram realizados com reatores em batelada de 2300 mL contendo meio de cultura específico para o crescimento de BRS. No ensaio de enriquecimento, com lactato de sódio (2230 mg/L) e acetato de sódio (670 mg/L) na ausência de tolueno, ocorreu consumo total de sulfato (aproximadamente 1070 mg/L) em 192 horas e percentual de metano de 31% em 72 horas. A degradação do tolueno foi realizada em reatores sulfetogênicos e metanogênicos. Nos reatores sulfetogênicos alimentados com 2,1 mg/L e 7,7 mg/L houve degradação total do tolueno em 264 e 792 horas, respectivamente. Nesses reatores foi observado consumo total de sulfato e percentual de metano de aproximadamente 20,9%. Nos reatores metanogênicos a degradação do tolueno foi de, no máximo, 53%, e percentual de metano de 27,3% em 1032 horas. Nas condições sulfetogênicas, a degradação do tolueno foi mais rápida se comparada às condições metanogênicas. E em ambas as condições, a produção de metano foi relacionada aos bacilos hidrogenotróficos. As alterações na diversidade da população microbiana presente nos reatores, observadas em microscopia ótica, foram confirmadas nas análises por biologia molecular. / The present work evaluated the anaerobic degradation of toluene by sulfate reducing bacteria (SRB), using anaerobic sludge from reactor UASB as inoculum. The essays were accomplished in batch reactors of 2300 mL containing specific culture medium for the growth of SRB. In the enrichment essay with sodium lactate (2230 mg/L) and sodium acetate (670 mg/L) without toluene accured total consumption of sulfate (approximately 1070 mg/L) in 192 hours and percentile of methane of 31% in 72 hours. The toluene degradation it was accomplished in sulfetogenics and methanogenics reactors. In the sulfetogenics reactors fed with 2,1 mg/L and 7,7 mg/L there was total degradation of toluene in 264 and 792 hours, respectively. In those reactors it was observed total consumption of sulfate and percentile of methane of approximately 20.9%. In the methanogenic reactors the degradation of toluene was to the utmost of 53%, accompanied of production of 27.3% of methane in 1032 hours. In the sulfetogenics conditions, the degradation of tolueno was faster if compared to the methanogenic conditions. In both conditions, the methane production was related to the hidrogenotrophic bacilli. The alterations in the diversity of the microbial population present in the reactors, observed by optic microscopy, were confirmed in the analysis by molecular biology.
96

Estudo de tratabilidade de lixiviado de aterro sanitário submetido à eletro-oxidação como pré-tratamento a um sistema de lodos ativados operado em batelada / Study treatability of landfill leachate subjected to electro-oxidation as a pretreatment to an activated sludge batch system

Natália de Souza Pelinson 08 November 2013 (has links)
O lixiviado de aterro sanitário é um efluente gerado a partir da mistura de líquidos produzidos na degradação de resíduos sólidos e a água pluvial que infiltra o depósito de material. Estudos na literatura, abordando tratamento de lixiviados de aterro sanitário, indicam que os processos biológicos podem não ser suficientes para que os padrões de lançamento vigentes na legislação sejam cumpridos. Neste contexto os processos oxidativos avançados estão sendo apontados como uma alternativa atrativa para efluentes que apresentam baixa biodegradabilidade. A presente pesquisa objetivou avaliar, em escala de bancada, a tratabilidade do lixiviado de aterro sanitário com aplicação do tratamento de oxidação eletroquímica seguida pelo tratamento biológico de um sistema de lodos ativados operado em batelada. A eletro-oxidação promove a remoção ou degradação de espécies poluentes, direta ou indiretamente, por meio de processos que não necessitam de adição de grandes quantidades de produtos químicos. Nos ensaios realizados com lixiviado bruto e com lixiviado alcalinizado submetido ao tratamento físico-químico de air stripping não houve necessidade de adicionar eletrólitos suporte para a oxidação química ocorrer e ao longo de tais ensaios a matéria foi mensurada quanto à DQO, COT e COD. Quando aplicada a eletro-oxidação no lixiviado bruto (sem tratamento prévio), houve 87% de remoção de DQO utilizando o anodo DDB com aplicação de 48 A h L-1 (densidade de corrente de 100 mA cm-2) e 65% de remoção da DQO quando utilizado o anodo DSA, nas mesmas condições. Analogamente, foram obtidos valores percentuais de remoção de COT de 70 e 60%, respectivamente e ainda 61 e 67% em relação ao COD. A fim de se complementar os estudos quanto à atuação da eletroquímica no tratamento do lixiviado de aterros sanitários, o efluente eletro-oxidado foi adicionado a um sistema de lodos ativados em duas proporções volumétricas distintas (2,5 e 5%) combinadas com esgoto sanitário (97,5 e 95%, respectivamente). Para controle e possível análise na eficiência, foram realizados ensaios com lixiviado bruto (5% de lixiviado bruto e 95% de esgoto sanitário) e somente esgoto sanitário (100%). Foram obtidos valores de remoção de DQO de: 75% em condição 100% esgoto sanitário, 64% com adição 2,5% de lixiviado eletro-oxidado, 57% com adição de 5% de lixiviado eletro-oxidado e 38% com adição de 5% de lixiviado bruto, além de valores percentuais de remoção de COT em cerca de 56, 52, 47 e 37%, respectivamente. E ainda foram obtida remoções nos valores de DBO na ordem de 91, 87, 64 e 24%, respectivamente. De forma geral, o sistema combinado proposto atingiu eficiências consideráveis e se mostrou compatível com o intuito de se estudar o aumento da tratabilidade por meio da aplicação de processos eletroquímicos em lixiviado bruto. / The landfill leachate is a wastewater generated from the mixture of liquids produced in the degradation of solid waste and rainwater that infiltrates the landfill. Studies in the literature approaching the treatment of landfill leachate indicate that biological processes may not be sufficient for the discharge standards prevailing in the present legislation. In this context the advanced oxidation processes (AOP) are being singled out as an attractive alternative for wastewater with a low biodegradability. This study aimed to evaluate, in a bench scale treatability of landfill leachate treatment with application of electrochemical oxidation followed by biological treatment of an activated sludge batch system. The electro-oxidation promotes the removal or degradation of pollutants species directly or indirectly, through processes which do not require addition of large amounts of chemicals. For tests with raw leachate and leachate with alkaline subjected to physico- chemical treatment of air stripping, there was no need to add support for electrolytes and chemical oxidation occurs over such trials the subject was measured as the COD, TOC and DOC. When applied the electro-oxidation in the raw leachate (without treatment) was reached 87% for COD removal using the DDB anode with the application of 48 L h-1 (current density 100 mA cm-2) and 65% COD removal when using the DSA anode under the same conditions. Similarly, the percentage values of TOC removal are 70 and 60 % respectively and also 61 and 67% compared to the DOC was obtained. In order to complement the studies regarding the performance of the electrochemical treatment of landfill leachate, the electro-oxidized effluent was added to an activated sludge system in two different volume ratios (2,5 and 5%) combined with sewage (97.5 and 95%, respectively). For control and possible efficiency analysis, testing with raw leachate (5% and 95 % crude leachate sanitary sewer) and only sanitary wastewater (100 %) were performed. Values of COD removal was obtained: 75% in 100% sewage condition, 64% with addition of 2,5% leachate electro- oxidized , with 57% addition of 5% leachate electro- oxidized and 38% with the addition of 5% raw leachate , and percentage values of TOC removal by about 56, 52, 47 and 37% , respectively. And BOD removal values were obtained in the order of 91, 87, 64 and 24%, respectively. In general, the proposed combined system has achieved considerable efficiency and proved to be compatible with the aim of studying the increased tractability through the use of electrochemical processes raw leachate.
97

Efeito da variação gradual da taxa de recirculação do lixiviado em reatores anaeróbios híbridos na digestão da fração orgânica dos resíduos sólidos urbanos / Effect of the gradual variation of the leachate recirculation rate in hybrid anaerobic reactors treating the organic fraction of municipal solid wastes

Souto, Gabriel D'Arrigo de Brito 09 June 2005 (has links)
O presente estudo teve por finalidade testar a hipótese de que o uso de uma taxa de recirculação variável do lixiviado de um reator tratando a fração orgânica dos resíduos sólidos urbanos domésticos, em um sistema em batelada híbrido, seria capaz de acelerar a degradação deste substrato em comparação com um sistema idêntico, porém que operasse com taxa de recirculação constante. Dois conjuntos de reatores foram operados, um com taxa de recirculação constante (sistema controle) e o outro com taxa de recirculação variável (sistema experimental). Os reatores foram mantidos em sala climatizada, com temperatura mantida em 35 ºC '+ OU -' 1 ºC. Cada conjunto era composto de um reator de sólidos, preenchido com o resíduo a ser digerido misturado a lixiviado de aterro sanitário, e um filtro anaeróbio, destinado a tratar o lixiviado que saía do primeiro. O substrato utilizado foi a fração orgânica dos resíduos sólidos urbanos domésticos padronizada (FORSUDp). Diversas variáveis foram medidas para o acompanhamento do processo: DQO de amostras filtradas e não filtradas, alcalinidade total, alcalinidade a ácidos voláteis, série de sólidos, nitrogênio total Kjeldahl e amoniacal, fósforo total, ácidos voláteis e composição do biogás por cromatografia gasosa. Também se acompanhou o desenvolvimento da microbiota anaeróbia por microscopia óptica de contraste de fase e fluorescência. A microscopia eletrônica de varredura indicou desenvolvimento de biofilme no meio suporte dos filtros anaeróbios. Concluiu-se que a taxa de recirculação variável consegue acelerar o processo, além de alterar de forma significativa o comportamento dos reatores e a forma de interação entre os mesmos / The objective of this study was to test the following hypothesis: varying the leachate recirculation rate in a hybrid batch reactor would make it possible to shorten the time required for the digestion of MSW, in comparison to a similar system operating with constant recirculation rate. Two sets of reactors were operated, one with constant recirculation rate (control system) and the other with varying rate (experimental system). The reactors were kept in a room which internal temperature was controlled. The temperature was kept at 35 ºC '+ OU -' 1ºC. Each set of reactors was composed of a solids reactor, filled with solid wastes and inoculated with landfill leachate, and an anaerobic filter, that should treat the leachate form the first one. The substract used was the standardized organic fraction of the municipal solid wastes (FORSUDp). Several parameters were measured for process monitoring: COD (in filtered and not filtered samples), total alkalinity, volatile acids alkalinity, solids, Kjeldahl nitrogen, ammonium nitrogen, total phosphorus, volatile acids by gas chromatography and biogas composition. The development of the anaerobic microorganisms was observed with phase-contrast and fluorescence microscopy. Scanning electron microscopy of the packed bed media showed biofilm development. It was concluded that the varying leachate recirculation rate proved to be able to enhance the degradation process. Besides, this operational strategy entirely changed the behaviour and interaction of the reactors
98

Tratamento de soro de queijo no ASBR: influência da estratégia de alimentação / Whey treatment in ASBR: influence of feeding strategy

Damasceno, Leonardo Henrique Soares 16 April 2004 (has links)
Avaliou-se o desempenho do reator anaeróbio em batelada seqüencial com biomassa imobilizada (ASBBR) no tratamento de soro de queijo quanto submetido a diferentes estratégias de alimentação e cargas orgânicas volumétricas (COV). O reator operou com agitação mecânica através de impelidor do tipo hélice na rotação de 500 rpm. Um volume de 2 litros foi alimentado por ciclo com 1 litro de volume residual, totalizando 3 litros. O substrato utilizado foi soro de queijo desidratado reconstituído. Suplementou-se o sistema com NaHCO3 na razão de 50% NaHCO3/DQO. Foram testadas as seguintes COVs: 2, 4, 8 e 12 gDQO/l.d. Para ciclos de 8 horas e em cada COV, três estratégias de alimentação foram testadas: (a) operação em batelada com ciclo de 8 horas, (b) batelada alimentada de 2 horas (c) batelada alimentada de 4 horas. Na COV de 2 gDQO/l.d, a conversão de matéria orgânica como DQO em amostras filtradas foi de 92, 96 e 91% para as estratégias de alimentação (a), (b) e (c), respectivamente. Para a COV de 4 gDQO/l.d, o desempenho foi de 94, 97 e 93%, respectivamente. Para a COV de 8 gDQO/l.d houve redução nas eficiências de conversão a 83, 85 e 86%, respectivamente. O aumento da COV para 12 gDQO/l.d, resultou na redução em eficiências de 72, 73 e 81%, respectivamente. Os perfis durante os ciclos da concentração de ácidos voláteis totais mostraram que, apesar do aumento gradual com o tempo de enchimento aumentando, nenhuma diferença significativa foi detectada em termos dos seus valores máximos. Foi observada a redução de ácido propiônico como conseqüência do aumento do tempo de enchimento. Assim, para COV de 2 e 4 gDQO/l.d, a estratégia de alimentação (b) proporcionou maiores eficiências de conversão e estabilidade operacional, enquanto que este comportamento foi observado na estratégia de alimentação (c) para os valores de COV de 8 e 12 gDQO/l.d. / The performance of an anaerobic sequencing batch biofilm reactor (ASBBR) treating cheese whey was evaluated when subjected to different feeding strategies and volumetric organic loads (VOL). The reactor operated under mechanical stirring provided by helix impellers at rotor speed of 500 rpm. A volume of 2 l was fed per cycle with 1 l of residual volume, totalizing 3 l. Reconstituted dehydrated cheese whey was used as substrate. NaHCO3 was supplemented at a ratio of 50% NaHCO3/COD. The following VOLs were tested: 2, 4, 8 and 12 gCOD/l.d. For 8-h cycles and each value of VOL three feed strategies were tested: (a) batch operation with 8-h cycle; (b) 2-h fed-batch operation; and (c) 4-h fed-batch. In the VOL of 2 gCOD/l.d, organic matter conversions as COD were 92, 96 and 91%, for feeding strategies (a), (b) and (c), respectively. For the VOL of 4 gCOD/l.d, performance values were 94, 97 and 93%, respectively. For the VOL of 8 gCOD/l.d there was a reduction in conversion efficiency to 84, 85 and 86%, respectively. The increase of VOL to 12 gCOD/l.d resulted in the reduction in efficiency of 78, 73 and 81%, respectively. The profiles of total volatile acids concentration obtained during the cycles showed that despite its gradual increase with the increasingly filling time, no significant differences were detected in terms of maximum values. Reduction in proprionic acid concentration along the cycle were observed as consequence of the increase of the filling time. Thus, for VOL of 2 and 4 gCOD/l.d feeding strategy (b) provided higher conversion efficiency and operation stability. This behavior was similar to that observed for the feeding strategy (c) at the VOL of 8 and 12 gCOD/l.d.
99

Redução de sulfato em biorreator operado em batelada e batelada alimentada seqüenciais contendo biomassa granulada com agitação mecânica e Draft-Tube / Sulfate reduction in bioreactor in sequencing batch and fed-batch containing granulated biomass with mechanical stirring and draft-tube

Mockaitis, Gustavo 26 March 2008 (has links)
O presente projeto avaliou um reator anaeróbio operado em batelada e batelada alimentada seqüenciais (ASBR), em ciclos de 8 horas, utilizando biomassa granulada e agitação mecânica em um draft-tube, alimentado com água residuária sintética (500 mgDQO/L), contendo sulfato em diferentes relações DQO/[\'SO IND.4\' POT.2-\']. Em todos os ensaios o reator apresentou uma operação estável, produzindo alcalinidade e com concentração de ácidos voláteis totais em níveis adequados. Para os tempos de alimentação de 10 min, 3 h e 6 h, respectivamente, as eficiências de remoção de sulfato foram de 30, 72 e 72% nas operações nas quais o reator foi alimentado com uma relação DQO/[\'SO IND.4\'POT.2-\'] de 1,34. Nos ensaios nos quais o reator foi alimentado na relação DQO/[\'SO IND.4\'POT. 2-\'] de 0,67, as eficiências para a redução de sulfato foram de 25, 58 e 55%, respectivamente. Na operação com relação DQO/[\'SO IND.4\'POT.2-\'] de 0,34, as eficiências para redução de sulfato foram de 23, 37 e 27%, respectivamente. Desta maneira, pode-se concluir que as operações em batelada alimentada favoreceram a remoção de sulfato, enquanto foi observado que nas operações em batelada a remoção de matéria orgânica atingiu melhores eficiências. / This present work evaluate an anaerobic sequencing batch reactor (ASBR), fed in batch and fed-batch, and cycles of 8 hours, using granulated biomass and mechanical stirring in a draft-tube, fed with synthetic wastewater (500 mgCOD/L), enriched with sulfate in some COD/[\'SO IND.4\'POT.2-\'] relations. In all operations the reactor showed a stable operation, producing alkalinity and maintaining the volatile acids in adequate levels. Considering the fed periods of 10 min, 3 h and 6 h, respectively, the removal efficiencies of the sulfate was 30, 72 e 72%, in the operations when the reactor was fed with a COD/[\'SO IND.4\'POT.2-\'] relation of 1,34. In the essays when the reactor was fed in COD/[\'SO IND.4\'POT.2-\'] relation of 0,67, the efficiencies of the sulfate reduction was 25, 58 e 55%, respectively. When the reactor was operated with COD/[\'SO IND.4\'POT.2-\'] relation of 0,34, the efficiencies of sulfate reduction 23, 37 e 27%, respectively. Thus, is possible to conclude that the operations in fed-batch increased the efficiency of sulfate removal, at what time was observed that in batch operations the organic matter removal attained improved efficiencies.
100

Influência da estratégia de alimentação no desempenho do reator anaeróbio em batelada seqüencial contendo biomassa imobilizada / Influence of feeding strategy on the performance of anaerobic sequencing batch reactor containing immobilized biomass

Borges, Alisson Carraro 07 April 2003 (has links)
Submeteu-se um reator anaeróbio operado em batelada seqüencial a diferentes tempos de enchimento, com o objetivo de verificar-se o desempenho do sistema. O reator, construído em acrílico e com capacidade de 6,3 L, tratou por ciclo um volume de 2,5 L de esgoto sintético com concentração de aproximadamente 500 mgDQO/L. O sistema foi operado à temperatura de 30 graus mais ou menos 1, com duração de 8 h para cada ciclo (tC) e agitação de 500 rpm implementada mecanicamente. Cubos de espuma de poliuretano foram usados como suporte para imobilização da biomassa. No início de cada ciclo, o reator foi carregado com 60 % do volume do esgoto; o restante foi preenchido durante tempos de enchimento (tF) que caracterizaram as diferentes estratégias de alimentação. Os resultados obtidos demonstram que para razões tF/tC <= 0,5 o sistema alcança médias de remoção de matéria orgânica acima de 75 % e 70% para amostras filtradas e não filtradas, respectivamente. Nos ensaios em que tF/tC > 0,5, registrou-se perda na eficiência e formação de polímeros extracelulares, apesar da estabilidade observada. O estudo contribuiu para o melhor entendimento do sistema e definição de técnicas de operação em futuras aplicações. / An anaerobic sequencing batch reactor was operated at different fill times with the objective to asses system performance. The reactor, made of plexiglas and with a capacity of 6.3 L, treated per cycle 2.5 L of synthetic wastewater with a concentration of nearly 500 mgCOD/L. The system was operated at a temperature of 30oC, with 8-h cycles (tC) and mechanical agitation rate of 500 rpm. Cubic particles of polyurethane foam were used as support material for anaerobic biomass immobilization. At the start of each cycle, the reactor was fed with 60 % of the wastewater volume, the remainder was filled at different feeding times (tF) that characterized the different feeding strategies. The results obtained showed that for a ratio of tF/tC <= 0.5 the system attained average filtered and non-filtered substrate removal efficiency of 75 % and 70 %, respectively. Ratios of tF/tC > 0.5, resulted in loss in efficiency and formation of extra cellular polymers, in spite of system stability. The study contributed to a better understanding of the system and definition of operational techniques for future applications.

Page generated in 0.1007 seconds