• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • 2
  • Tagged with
  • 15
  • 15
  • 12
  • 12
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de um fotômetro com fins didáticos

Mota, Fábio Alexandre Costa 26 February 2010 (has links)
Made available in DSpace on 2015-04-22T22:02:00Z (GMT). No. of bitstreams: 1 Capa da Dissertacao Fabio.pdf: 72495 bytes, checksum: eb902f0def752f5d58493cc98419e657 (MD5) Previous issue date: 2010-02-26 / Fundação de Amparo à Pesquisa do Estado do Amazonas / In this work was developed a photometer for didactic purposes for use in the context of social themes chemicals, such as environmental chemistry and classes of analytical instrumentation, with total determination of total orthophosphate in water. The instrument was developed using cheap materials and easy disposal. The instrument consists of a yellow LED and LDR; the first is the source and the former the detector. The signal of the photometer is available by values in resistivity, within is measured with assistance of the digital multimeter. For the determination of the orthophosphate was used the Molybdenum Blue Colorimetric Method, using river waters as test samples. Procedures for analytical validation tests were for the most suitable configuration, choosing a bucket acrylic, range from 200 kW resistivity and use of cover to the apparatus, as well as checking the stability of the source. Accuracy, precision, recovery and linearity of the photometer were checked. The repeatability and intermediate precision had coefficients of variation average 3.0 and 2.8, respectively. Accuracy was examined with statistical comparison based upon test F and t for p < 0.05, with same measures evaluated in the photometer and spectrophotometer UV-Vis, for comparison. With 95% confidence level was revealed that there are significant differences between the values of concentration, and the results were satisfactory with the use of a correction factor The recovery tests were satisfactory, with variations between 97.6 and 107.3%. The linearity is satisfactory in the range 8-48 μmol l-1, with r2 values above 0.99. / Foi desenvolvido um fotômetro para fins didáticos para uso na contextualização de temas químicos sociais, como química ambiental, e em aulas de instrumentação analítica, com determinação de ortofosfato total em águas. Para sua construção foram usados materiais de baixo custo e de fácil aquisição. O aparelho consiste basicamente de um LED (Diodo Emissor de Luz) amarelo como fonte e LDR (Resistor Dependente de Luz) como detector. O sinal do fotômetro é dado em valores de resistividade, medida com uso de multímetro digital. Para a determinação do ortofosfato foi usado o método do azul de molibdênio, sendo águas de um igarapé poluído usados como amostras teste. Para procedimentos de validação analítica, foram feitos testes para configuração mais adequada, optando-se por cubeta de acrílico, escala de 200kW de resistividade e uso de cobertura no aparelho, assim como verificação da estabilidade da fonte. O aparelho foi validado usando critérios de precisão, exatidão, recuperação e linearidade. A precisão intermediária e repetibilidade apresentaram coeficientes de variação médios de 3,0 e 2,8, respectivamente. A exatidão do fotômetro foi verificada com comparação estatística baseadas nos testes F e t para p < 0,05, sendo as mesmas medidas feitas no fotômetro e espectrofotômetro UV-Vis, para fins de comparação. Com 95% de nível de confiança foi revelado que há diferenças significativas entre os valores de concentração, sendo que os resultados foram considerados satisfatórios com o uso de um fator de correção. Os testes de recuperação foram satisfatórios com variações entre 97,6 e 107,3%. A linearidade foi considerada satisfatória no intervalo de 8 a 48 μmol l-1, apresentando valores de r2 acima de 0,99.
2

Studies on the Elemental Measurement of Aerosols Using Microplasma Spectroscopy

Zheng, Lina January 2016 (has links)
No description available.
3

Development and Characterization of a Stopped-Flow-Bypass Analysis System With Applications To Biochemical Measurements

Hillard, Stephen Wayne 11 March 1997 (has links)
A new apparatus called Bypass Trapped Flow Analysis System (ByT-FAS) is described. A properly designed ByT-FAS gives an analyst the ability to use analyte sample volumes of 10 to 200 μL [or more] and reagent volumes of approximately the same size. The sample and reagent are injected into their respective carrier streams and attain physical steady state concentrations in the detection cell within approximately 15 to 45 seconds after injection. Upon achievement of simultaneous sample and reagent physical steady state concentrations, the system flow is diverted around the detection cell and the reaction mixture is trapped in the detection cell. The concentration of the sample and reagent in the detection cell can be readily computed from knowledge of the original concentrations of the sample and reagent and the flow rates of the streams propelling the sample and reagent. ByT-FAS was demonstrated to be useful for direct measurements of analytes in liquid solutions and for assays which utilize equilibrium and/or kinetic methods to create measurable product(s) for ultraviolet/visible spectrophotometry, fluorimetry, and chemiluminescence. Enzyme activities and fundamental enzyme kinetic parameters (Kms, Kis, VMAXs) were determined directly. Genetic transcription levels of luciferase in whole intact E. coli cells were also determined using chemiluminescent detection. Flow system configuration, components, and flow ratios were investigated for their effects on achieving physical steady state signals in the detector. It is believed that this new type of instrumentation will be of significant use for the analytical chemical, biochemical, molecular biology, biotechnology, environmental, pharmaceutical and medical communities for those measurements which require direct knowledge of the concentration of the reactants and products during quantitation. / Ph. D.
4

Eletroforese com dupla detecção condutométrica sem contato e espectrometrica de massas / Electrophoresis with dual contactless conductometric detection and mass spectrometry

Francisco, Kelliton José Mendonça 03 October 2017 (has links)
A presente tese descreve o aprimoramento do acoplamento de eletroforese capilar/espectrometria de massas com ionização por electrospray (CE-ESI-MS) (1) pelo desenvolvimento de estratégias de controle de temperatura e posicionamento e (2) pela inclusão de dois detectores condutométricos sem contato (C4Ds) ao capilar de separação eletroforética de modo a se obter informações complementares àquelas fornecidas pelo MS. Os primeiros aprimoramentos consistiram na introdução de uma plataforma móvel para o CE e um módulo de refrigeração da porção externa do capilar. Com estes aprimoramentos, foi possível realizar estudo de cinética de hidrólise de monoetilcarbonato (MEC) por CE-ESI-MS, obtendo-se, pela primeira vez, o valor da energia de ativação de 99 ± 8 kJ mol-1. Posteriormente, foi desenvolvida uma série de protótipos de cartuchos impressos 3D em ABS, permitindo a introdução de até dois C4Ds. Além da inclusão dos detectores, a versão aprimorada do cartucho permitiu um bom comportamento térmico da coluna, permitindo que, tal como em sistemas CE-DAD, correntes eletroforéticas alcancem valores da ordem de 100 &#181;A sem efeitos térmicos indesejados (o que não ocorre ao se utilizar o cartucho original para CE-MS). As possibilidades do arranjo CE-(C4D)2-ESI-MS foram demonstradas pelo desenvolvimento de métodos analíticos de separação para: (1) açúcares a pH 11,2; (2) aminas biogênicas a pH 2,0 e (3) ácidos carboxílicos a pH 7,5. A compatibilização dos eletroferogramas dos C4Ds ao longo do capilar e do ESI-MS no final do capilar foi conseguida pela correção da escala de tempo. Assim, as informações obtidas com os vários detectores podiam ser facilmente complementadas. Devido à baixa seletividade intrínseca do C4D, este se mostra amplamente complementar ao ESI-MS, que é o sistema mais seletivo para CE disponível na atualidade. Embora este último também seja altamente sensível, o C4D se mostrou comparável ou até mais apropriado em alguns casos. Assim, esta combinação única apresenta um grande potencial como ferramenta analítica. / The capillary electrophoresis/mass spectrometry with electrospray source (CE-ESI-MS) was improved by (1) the development of new temperature control and positioning systems and (2) the inclusion of two capacitively coupled contactless conductivity detectors (C4Ds) to the electrophoretic separation capillary allowing to obtain complimentary information to the MS. The initial improvements were the introduction of a sliding platform for the CE equipment and a thermostatic module for the portion of the capillary outside the CE environment. These improvements allowed obtaining, for the first time, the activation energy of hydrolysis reaction of monoethyl carbonate: 99 ± 8 kJ mol-1. However, the most important improvement was the development of 3D-printed cartridge allowing the inclusion of up to two C4Ds along the capillary. This cartridge also allowed a significant improvement of the thermal control over the capillary. No significant difference of the original CE-DAD was observed for electrophoretic currents up to 100 &#181;A. The original CE-MS has similar behavior only until 60 &#181;A. New possibilities of the CE-(C4D)2-ESI-MS setup were demonstrated by the development of analytical methods for separation of: (1) sugars at pH 11.2, (2) biogenic amines at pH 2.0, and (3) carboxylic acids at pH 7.5. The electropherograms of the three detectors were made compatible by correcting the time scales. Therefore, the information obtained from the three detectors may be easily complemented. Thanks to the intrinsic low-selectivity of the C4D, that is complementary to the MS, which is the most selective detector for CE today. Although MS is also highly sensitive, C4D had similar or even better performance in some cases. Therefore, this unique combination is powerful analytical tool
5

Estratégias em fluxo para a determinação de acidez, sulfato e cloreto em etanol hidratado combustível / Flow-based strategies for the determination of acidity, sulfate and chloride in hydrous ethanol fuel

Lima, Manoel de Jesus de Aquino 26 April 2019 (has links)
Acidez, sulfato e cloreto são constantemente relacionados ao potencial corrosivo do etanol hidratado combustível (EHC), pois mesmo em baixas concentrações podem induzir processos que danificam dutos de transporte e peças dos veículos. Em vista dessa problemática, as agências reguladoras estabeleceram limites máximos para estes constituintes a serem determinados por titulação, no caso da acidez, e por cromatografia de íons para cloreto e sulfato. Os procedimentos propostos no presente trabalho tiveram como objetivo apresentar alternativas de baixo custo, instrumentação simples, pouca influência do analista (automação das etapas) e baixa geração de efluentes. Para a avaliação da acidez, foi construído um titulador automático, explorando um algoritmo de procura binária em um sistema de análises químicas em fluxo baseado em multicomutação. Sob condições otimizadas, o sistema foi capaz de titular amostras de etanol diluídas a 50% (v/v), gerando cerca de 11,5 mL de efluente por determinação, com coeficiente de variação < 1,0% e frequência de análises > 10 h-1. Além disso, o sistema não necessitou de calibração, fazendo com que todas as etapas fossem realizadas automaticamente. Para as determinações de sulfato e de cloreto, foram montados módulos de análises baseados em fluxo-batelada com detecção espectrofotométrica. Os analitos foram determinados sem etapas de preparo de amostra. Para realizar a determinação indireta do sulfato, foi empregada a reação de deslocamento dos íons bário do complexo dimetilsulfonazo III de bário (DMS-Ba+), promovido pelos íons sulfato; para a determinação de cloreto, foi explorado o efeito dos íons cloreto na fotogeração (UV) de nanopartículas de prata (Ag-NPs). Para sulfato e cloreto, as faixas lineares de resposta, limites de detecção (95%) e coeficientes de variação foram: 0,1 - 1,5 mg L-1 e 0,05 - 0,8 mg L-1; 48 e 12 µg L-1 e 1,0% e 2,2%, respectivamente. Na determinação de sulfato e cloreto, as frequências de análises foram de 35 e 30 h-1, respectivamente; com geração de efluentes < 5 mL por determinação em ambos os procedimentos. Todos os procedimentos desenvolvidos atendem aos limites estabelecidos pela agência reguladora brasileira, e os resultados obtidos foram comparados com os procedimentos oficiais, não havendo diferença significativa entre métodos, ao nível de 95% de probabilidade / Acidity, sulfate and chloride are often related to the hydrous ethanol fuel (HEF) corrosive potential, as even at low concentrations they may induce processes deleterious to transportation ducts and vehycle components. Thus, the regulatory agencies established maximum limits for these constituents to be determined by titration in the case of acidity and by chromatography of ions for chloride and sulfate. The procedures herein proposed aimed at to present alternatives of low cost, simple instrumentation, little influence of the analyst (automation of the stages) and low generation of effluents. For acidity evaluation, an automatic titrator exploiting a binary search algorithm in a analytical flow system based on multicommutation was built up. Under optimized conditions, the system was able of titrating ethanol samples diluted to 50% (v/v), generating about 11.5 mL of effluent per determination, with coefficient of variation <1.0% and sample throughput > 10 h-1. Moreover, the flow system did not require calibration, and all steps were automatically performed. For sulfate and chloride determinations, flow-batch analytical systems with spectrophotometric detection were set up, allowing the analytes to be determined without sample preparation steps. For the indirect determination of sulfate, the reaction of displacement of the barium ions from its dimethylsulfonazo III complex (DMS-Ba+) promoted by the sulfate ions was used; for the determination of chloride, the effect of this analyte on the photo-generation (UV) of silver nanoparticles (Ag-NPs) was exploited. For sulfate and chloride, linear response ranges, detection limits (95% confidence level) and coefficients of variation were: 0.1 - 1.5 and 0.05 - 0.8 mg L-1; 48 and 12 ?g L-1, and 1.0 and 2.2%, respectively. In the sulfate and chloride determinations, the analytical frequency were 35 and 30 h-1, respectively, with effluents generation of < 5 mL per determination for both procedures. The developed procedures meet the limits established by the Brazilian regulatory agency, and results obtained were compared with the official procedures, and no significant differences between methods at the 95% probability level were found
6

Desenvolvimento de uma câmara flow-batch com aquecimento direto e de procedimentos analíticos para determinação fotométrica de açúcares redutores em vinhos e de manganês em amostras vegetais / Development of a flow- batch chamber with direct heating and analytical procedures for photometric determination of reducing sugars in wine and manganese in plant samples

Brasil, Marcos Augusto Stolf 27 July 2016 (has links)
Neste trabalho foi desenvolvido um sistema analítico tendo como elemento central uma câmara flow-batch com aquecimento direto e fotômetro acoplado, empregado para determinação de açúcares redutores em vinhos e de manganês em amostras vegetais. A instrumentação foi implementada utilizando o conceito flow-batch e o processo de multicomutação em fluxo. A proposta da câmara com aquecimento direto foi concebida para viabilizar procedimentos analíticos baseados em reações lentas. Adicionalmente, foi realizada a instalação do sistema de detecção fotométrica no próprio corpo da câmara, eliminando a necessidade de resfriamento e transporte da solução para outro componente para monitoramento. Esta estratégia possibilitou a redução das dimensões do sistema e o incremento na frequência de amostragem. O controle do sistema é realizado usando aplicativo desenvolvido na linguagem Visual Basic®, o qual aciona seus componentes e realiza a leitura do sinal analítico através de uma interface. Para propulsão dos fluidos é utilizada uma bomba peristáltica multicanal, ambos dispositivos foram desenvolvidos dentro do presente trabalho. Para a determinação de açúcares redutores em vinho, o método analítico adotado utiliza como reagente cromogênico o hexacianoferrato (III) de potássio em meio alcalino sob aquecimento (50 oC) e leitura em 420 nm. O sistema apresentou uma faixa de resposta linear entre 0,75 e 6% (m/v) frutose (R2= 0,999), limite de detecção de 0,14% (m/v; n = 11), desvio padrão relativo menor que 4%, e frequência analítica de 75 determinações por hora. O procedimento para a determinação de manganês foi baseado na reação de oxidação à permanganato, utilizando como agente oxidante periodato de sódio em meio ácido, aquecimento a 55 oC, e leitura em 530 nm. Após estabelecer as variáveis de controle, o sistema apresentou faixa de resposta linear entre 5 e 30 mg.L-1(R² = 0,997), limite de detecção de 2 mgL-1 (n = 11) Mn2+, desvio padrão relativo de 5%, e frequência analítica de 40 determinações por hora. A exatidão dos resultados foi avaliada aplicando o teste t-Student, onde foram comparados os resultados obtidos com os procedimentos propostos com aqueles obtidos com métodos de referência, e não foram observadas diferenças significativas ao nível de confiança de 95 % / In this work was developed an analytical system, employing a flow-batch chamber with direct heating coupled to a LED based photometer, which was tailored for the determination of reducing sugars in wine and manganese in plant samples. The instrumentation was implemented using the flow-batch concept and multicommutation flow analysis process. The proposed camera with direct heating was designed to enable analytical procedures based on slow reactions. The photometer coupling to the flow-batch chamber body, eliminated the need for a cooling step and as well as solution transportation for another component, where signal would be monitored. This strategy allowed the reduction of the system dimensions, and enabling an increase in sampling frequency. The system control was performed using software developed in Visual Basic ® language, which drove the actives components of the system. For fluid propulsion was used a multichannel peristaltic pump, which was also developed in the present work. For the determination of reducing sugars in wine, the analytical procedure was based on the reaction of potassium hexacyanoferrate (III) in an alkaline medium under heating at 50 ° C, which was monitored at 420 nm. The procedure provided a linear response ranging from 0.75 to 6.00 % (w / v) fructose (R2 = 0.999), a 0.14% limit of detection (w/v, n = 11), a relative standard deviation less than 4.0 %, and an analytical frequency of 75 determination per hour. The procedure for the determination of manganese was based on the permanganate oxidation reaction in acid medium, using sodium periodate solution as an oxidizing reagent. The flow-batch was maintained at 55 ° C, and signal was monitored at 530 nm. After establishing the control variables, the procedure provided a linear response ranging from 5.0 to 30.0 mg L-1 (R2 = 0.997), a detection of limit 2.0 mg L-1 (n = 11) Mn2+, a relative standard deviation of 5.0 % (n = 8) and an analytical frequency of 40 determination per hour. The accuracy of the results was assessed by applying the Student t-test between results obtained employing the proposed procedures and a reference method, and not significant difference at 95 % confidence level was observed
7

Quimiometria aplicada à cromatografia líquida multidimensional capilar hifenizada a espectrometria de massas sequencial para proteômica shotgun / Chemometric approach to a capillary multidimensional liquid chromatography coupled to tandem mass spectrometry for shotgun proteomics

Batiston, Weliton Pedro 19 February 2015 (has links)
O sequenciamento genético do DNA humano permitiu maior compreensão da funcionalidade dos seres vivos e principalmente a causa de muitas doenças. Entretanto, os estudos em genética têm se limitado a resolverem os problemas da ciência, e atualmente, a solução para o avanço nessa área tem se atribuído à proteômica. Dessa forma, a pesquisa em química analítica intensificou-se na busca de estratégias melhores para a caracterização de proteomas, em três aspectos principais: preparo de amostra, desenvolvimento da instrumentação analítica e bioinformática. Verifica-se a possibilidade da aplicação de muitas técnicas, atualmente, destaca-se a análise de peptídeos (proteômica shotgun) por cromatografia líquida multidimensional acoplada à espectrometria de massas sequencial (LC/LC-MS/MS), devido à possibilidade de automatização, minimização dos problemas e resultados satisfatórios na análise de amostras biológicas complexas. Portanto, neste trabalho desenvolveu-se um método LC/LC-MS/MS (modalidade on-line column switching) o qual se constitui de coluna trocadora catiônica (homemade), trap de aprisionamento e limpeza, coluna capilar hidrofóbica e separação e detecção por espectrometria de massas sequencial automatizada. Com a proposta de uma instrumentação analítica aperfeiçoada, realizamos a confecção de um trap com partículas de elevada retenção dos peptídeos, o que permite ótima recuperação de amostra. Por se tratar de uma técnica de elevada complexidade instrumental, devido a difícil compatibilidade entre as dimensões cromatográficas, possíveis perda de analito no processo e elevado tempo de análise, propomos uma nova abordagem de otimização, por meio de estudos quimiométricos. Assim, neste trabalho, foram avaliados doze parâmetros instrumentais e destes houve uma simplificação de apenas dois fatores, responsáveis por 95% da resposta ótima do método. Este fato permitiu valores da cobertura da proteína de BSA (82,54%), número de peptídeos (65) e score (2134,05) superiores aos reportados na literatura, os quais apresentam tempos de análise maiores. Este estudo fornece informações do comportamento químico dos peptídeos em relação ao método proposto, por meio de uma superfície de resposta e equação matemática que pode contribuir para a aplicação em diferentes proteomas. / The genetic sequence of human DNA has helped the comprehension of life and principally the cause of various diseases. However, genetic studies have limited to resolve science problems and currently solutions to advance in this field have been attributed to proteomics. Thus, the analytical chemistry has intensified on the search for a better strategy to proteomic characterization in three principal aspects: sample preparation, development of analytical instrumentation, and bioinformatics. Proteomics involves the application of many techniques, currently; the peptide analyses (shotgun proteomics) by multidimensional liquid chromatography coupled to tandem mass spectrometry (LC/LC-MS/MS) is the state of the art. The main reasons are because it allows full system automation, less problems in repeatability, and adequate results in analysis of highly complex biological samples. Therefore, this dissertation developed the method LC/LC-MS/MS (modality on-line column switching), this has a cation exchange column (homemade), trap column to clean, hydrophobic capillary column and separation and detection by tandem mass spectrometry. We have proposed an improved analytical instrumentation, with a homemade trap that particles have high retention of peptide, which permit great recuperation of samples. Because it is an instrumental technique difficult, such as, obtain compatibility between the chromatography dimensions, can lose samples in the process and long time analysis, we have proposed a new optimization approach with chemometric analysis of data. On that, were evaluated twelve instrumental parameters and there was a simplification only two factors, these were responsible for 95% of greater response of method. As a result, the coverage of BSA protein was 82,54%, number of peptides 65 and score of 2134,05 values of high significance if compare from that there are in literature that presented greater time analysis. This work describes information about chemistry of peptides to method proposed through a surface of response and math equation that can contribute to different proteomes.
8

Quimiometria aplicada à cromatografia líquida multidimensional capilar hifenizada a espectrometria de massas sequencial para proteômica shotgun / Chemometric approach to a capillary multidimensional liquid chromatography coupled to tandem mass spectrometry for shotgun proteomics

Weliton Pedro Batiston 19 February 2015 (has links)
O sequenciamento genético do DNA humano permitiu maior compreensão da funcionalidade dos seres vivos e principalmente a causa de muitas doenças. Entretanto, os estudos em genética têm se limitado a resolverem os problemas da ciência, e atualmente, a solução para o avanço nessa área tem se atribuído à proteômica. Dessa forma, a pesquisa em química analítica intensificou-se na busca de estratégias melhores para a caracterização de proteomas, em três aspectos principais: preparo de amostra, desenvolvimento da instrumentação analítica e bioinformática. Verifica-se a possibilidade da aplicação de muitas técnicas, atualmente, destaca-se a análise de peptídeos (proteômica shotgun) por cromatografia líquida multidimensional acoplada à espectrometria de massas sequencial (LC/LC-MS/MS), devido à possibilidade de automatização, minimização dos problemas e resultados satisfatórios na análise de amostras biológicas complexas. Portanto, neste trabalho desenvolveu-se um método LC/LC-MS/MS (modalidade on-line column switching) o qual se constitui de coluna trocadora catiônica (homemade), trap de aprisionamento e limpeza, coluna capilar hidrofóbica e separação e detecção por espectrometria de massas sequencial automatizada. Com a proposta de uma instrumentação analítica aperfeiçoada, realizamos a confecção de um trap com partículas de elevada retenção dos peptídeos, o que permite ótima recuperação de amostra. Por se tratar de uma técnica de elevada complexidade instrumental, devido a difícil compatibilidade entre as dimensões cromatográficas, possíveis perda de analito no processo e elevado tempo de análise, propomos uma nova abordagem de otimização, por meio de estudos quimiométricos. Assim, neste trabalho, foram avaliados doze parâmetros instrumentais e destes houve uma simplificação de apenas dois fatores, responsáveis por 95% da resposta ótima do método. Este fato permitiu valores da cobertura da proteína de BSA (82,54%), número de peptídeos (65) e score (2134,05) superiores aos reportados na literatura, os quais apresentam tempos de análise maiores. Este estudo fornece informações do comportamento químico dos peptídeos em relação ao método proposto, por meio de uma superfície de resposta e equação matemática que pode contribuir para a aplicação em diferentes proteomas. / The genetic sequence of human DNA has helped the comprehension of life and principally the cause of various diseases. However, genetic studies have limited to resolve science problems and currently solutions to advance in this field have been attributed to proteomics. Thus, the analytical chemistry has intensified on the search for a better strategy to proteomic characterization in three principal aspects: sample preparation, development of analytical instrumentation, and bioinformatics. Proteomics involves the application of many techniques, currently; the peptide analyses (shotgun proteomics) by multidimensional liquid chromatography coupled to tandem mass spectrometry (LC/LC-MS/MS) is the state of the art. The main reasons are because it allows full system automation, less problems in repeatability, and adequate results in analysis of highly complex biological samples. Therefore, this dissertation developed the method LC/LC-MS/MS (modality on-line column switching), this has a cation exchange column (homemade), trap column to clean, hydrophobic capillary column and separation and detection by tandem mass spectrometry. We have proposed an improved analytical instrumentation, with a homemade trap that particles have high retention of peptide, which permit great recuperation of samples. Because it is an instrumental technique difficult, such as, obtain compatibility between the chromatography dimensions, can lose samples in the process and long time analysis, we have proposed a new optimization approach with chemometric analysis of data. On that, were evaluated twelve instrumental parameters and there was a simplification only two factors, these were responsible for 95% of greater response of method. As a result, the coverage of BSA protein was 82,54%, number of peptides 65 and score of 2134,05 values of high significance if compare from that there are in literature that presented greater time analysis. This work describes information about chemistry of peptides to method proposed through a surface of response and math equation that can contribute to different proteomes.
9

Desenvolvimento de uma câmara flow-batch com aquecimento direto e de procedimentos analíticos para determinação fotométrica de açúcares redutores em vinhos e de manganês em amostras vegetais / Development of a flow- batch chamber with direct heating and analytical procedures for photometric determination of reducing sugars in wine and manganese in plant samples

Marcos Augusto Stolf Brasil 27 July 2016 (has links)
Neste trabalho foi desenvolvido um sistema analítico tendo como elemento central uma câmara flow-batch com aquecimento direto e fotômetro acoplado, empregado para determinação de açúcares redutores em vinhos e de manganês em amostras vegetais. A instrumentação foi implementada utilizando o conceito flow-batch e o processo de multicomutação em fluxo. A proposta da câmara com aquecimento direto foi concebida para viabilizar procedimentos analíticos baseados em reações lentas. Adicionalmente, foi realizada a instalação do sistema de detecção fotométrica no próprio corpo da câmara, eliminando a necessidade de resfriamento e transporte da solução para outro componente para monitoramento. Esta estratégia possibilitou a redução das dimensões do sistema e o incremento na frequência de amostragem. O controle do sistema é realizado usando aplicativo desenvolvido na linguagem Visual Basic®, o qual aciona seus componentes e realiza a leitura do sinal analítico através de uma interface. Para propulsão dos fluidos é utilizada uma bomba peristáltica multicanal, ambos dispositivos foram desenvolvidos dentro do presente trabalho. Para a determinação de açúcares redutores em vinho, o método analítico adotado utiliza como reagente cromogênico o hexacianoferrato (III) de potássio em meio alcalino sob aquecimento (50 oC) e leitura em 420 nm. O sistema apresentou uma faixa de resposta linear entre 0,75 e 6% (m/v) frutose (R2= 0,999), limite de detecção de 0,14% (m/v; n = 11), desvio padrão relativo menor que 4%, e frequência analítica de 75 determinações por hora. O procedimento para a determinação de manganês foi baseado na reação de oxidação à permanganato, utilizando como agente oxidante periodato de sódio em meio ácido, aquecimento a 55 oC, e leitura em 530 nm. Após estabelecer as variáveis de controle, o sistema apresentou faixa de resposta linear entre 5 e 30 mg.L-1(R² = 0,997), limite de detecção de 2 mgL-1 (n = 11) Mn2+, desvio padrão relativo de 5%, e frequência analítica de 40 determinações por hora. A exatidão dos resultados foi avaliada aplicando o teste t-Student, onde foram comparados os resultados obtidos com os procedimentos propostos com aqueles obtidos com métodos de referência, e não foram observadas diferenças significativas ao nível de confiança de 95 % / In this work was developed an analytical system, employing a flow-batch chamber with direct heating coupled to a LED based photometer, which was tailored for the determination of reducing sugars in wine and manganese in plant samples. The instrumentation was implemented using the flow-batch concept and multicommutation flow analysis process. The proposed camera with direct heating was designed to enable analytical procedures based on slow reactions. The photometer coupling to the flow-batch chamber body, eliminated the need for a cooling step and as well as solution transportation for another component, where signal would be monitored. This strategy allowed the reduction of the system dimensions, and enabling an increase in sampling frequency. The system control was performed using software developed in Visual Basic ® language, which drove the actives components of the system. For fluid propulsion was used a multichannel peristaltic pump, which was also developed in the present work. For the determination of reducing sugars in wine, the analytical procedure was based on the reaction of potassium hexacyanoferrate (III) in an alkaline medium under heating at 50 ° C, which was monitored at 420 nm. The procedure provided a linear response ranging from 0.75 to 6.00 % (w / v) fructose (R2 = 0.999), a 0.14% limit of detection (w/v, n = 11), a relative standard deviation less than 4.0 %, and an analytical frequency of 75 determination per hour. The procedure for the determination of manganese was based on the permanganate oxidation reaction in acid medium, using sodium periodate solution as an oxidizing reagent. The flow-batch was maintained at 55 ° C, and signal was monitored at 530 nm. After establishing the control variables, the procedure provided a linear response ranging from 5.0 to 30.0 mg L-1 (R2 = 0.997), a detection of limit 2.0 mg L-1 (n = 11) Mn2+, a relative standard deviation of 5.0 % (n = 8) and an analytical frequency of 40 determination per hour. The accuracy of the results was assessed by applying the Student t-test between results obtained employing the proposed procedures and a reference method, and not significant difference at 95 % confidence level was observed
10

Estudos de adsorção e de equilíbrios no sistema cádmio(II)/piridina/cloreto. Desenvolvimento de instrumentação / Adsorption and equilibrium studies of the cadmium(II)/pyridine/chloride system; development of instrumentation

Gutz, Ivano Gebhardt Rolf 04 December 1978 (has links)
O presente trabalho começa por uma apresentação monográfica do fenômeno de adsorção, que dá acesso à bibliografia existente sobre o assunto. Numa extensa parte experimental desenvolveu-se um eletrodo de amálgama gotejante e um eletrodo de gota pendente mercúrio capaz de gerar gotas com área reprodutível dentro de &#177; 0,1%. Fez-se, também, a implantação da técnica da cronocoulometria, com os recursos disponíveis neste Instituto de Química. Realizou-se um estudo polarográfico preliminar onde se observaram diversos efeitos inibitivos sobre a reação de eletrodo do Cd(II), ligados á presença dos fenantrolino complexos de Cd(II) e de Fe(II), com participação de ânions. O sistema cádmio(II)/piridina/cloreto foi estudado potenciometricamente, tendo sido avaliadas as seguintes constantes globais de estabilidade &#946;ij = &#8204;CdpyiClj&#8204;/&#8204;Cd&#8204; &#8204;py&#8204; i&#8204;Cl&#8204;j (i, número de ligantes piridina, e j, de cloreto): &#946;01 = 25,36, &#946;02 = 96,0, &#946;03 = 48,3, &#946;04 = 65,8, &#946;10 = 23,5, &#946;11 = 550, &#946;12 = 2600, &#946;13 = 550, &#946;14 = 1100, &#946;20 = 690, &#946;21 = 9740, &#946;22 = 9400, &#946;30 = 270, &#946;31 = 3500, &#946;32 = 37400, &#946;40 = 8450, &#946;41 = 54400. Para chegar às constantes de equilíbrio usou-se um processo iterativo de cálculo. As medidas foram realizadas com um eletrodo de amálgama gotejante, após comprovar-se que o eletrodo íon-seletivo de cádmio de estado sólido é inadequado para esta finalidade. Empregou-se um novo tipo de diagramas para representar a contribuição percentual das espécies formadas, em função dos dois ligantes. Estudou-se, através da cronocoulometria, a adsorção do sistema Cd(II)/py/Cl-, em diversas condições, fixando a concentração do metal e do cloreto e variando-se a concentração de py. Ficou estabelecido que a adsorção dos complexos é um processo competitivo com a dos ligantes. Há sempre um máximo de adsorção na faixa de 0,1 a 0,5 M de py. Encontraram-se evidências de que as espécies mistas neutras são preferencialmente adsorvidas. / The present thesis starts with the monographic discussion of the adsorption phenomena, with several references. There is an extensive experimental part referred to the development of a simple dropping amalgam electrode, a hanging mercury drop electrode whose area is reproductible within 0,1%, and the introduction of the double step chronocoulometric method w1th the resources of this Chemistry Institute, was done. In a preliminary polarographic study, several inhibiting effects on the Cd(II) electrode reaction, due to the presence of cadmium(II) and iron(II) complexes of phen participation of some anions has been observed. A potentiometric study of the cadmium(II)/pyridine//chloride system lead to the evaluation of the overall stability, &#946;ij = &#8204;CdpyiClj&#8204;/&#8204;Cd&#8204; &#8204;py&#8204; i&#8204;Cl&#8204;j (i, number of py ligands and j of chloride ones): &#946;01 = 25,36, &#946;02 = 96,0, &#946;03 = 48,3, &#946;04 = 65,8, &#946;10 = 23,5, &#946;11 = 550, &#946;12 = 2600, &#946;13 = 550, &#946;14 = 1100, &#946;20 = 690, &#946;21 = 9740, &#946;22 = 9400, &#946;30 = 270, &#946;31 = 3500, &#946;32 = 37400, &#946;40 = 8450, &#946;41 = 54400. To obtain the equilibrium constants from the experimental data, an iterative calculation process was used. The measurements has been made with an amalgam electrode, after unsucessfull tests with a solid state cadmium ion selective electrode. A new type of diagram was used to present the percent distribution of the species with the change in the concentration of the ligands, in substitution to the predominance area diagram. In add1tion, the chronocoulometric study of the Cd(II)/ /py/Cl- system was done at several experimental conditions, by fixing the concentration of the metal and the chloride, and changing in wide extension the pyridine concentration. The adsorption of the complexes is a competitive process with the free ligands, and allways exhibits a maxima between .1 and .5M pyridine. There are strong evidences indicating that the neutral mixed species are preferabbly adsorbed.

Page generated in 0.1321 seconds