• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 6
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Projeto e desenvolvimento de um sistema piloto para tratamento de gases de exaustão

Kielling, José Adriano January 2004 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-graduação em Engenharia Química / Made available in DSpace on 2012-10-22T02:26:55Z (GMT). No. of bitstreams: 1 210371.pdf: 2186213 bytes, checksum: b3a0a9fc840036f97ef541e3f002b4b5 (MD5) / Odores provenientes de várias fontes proporcionam, sobre as pessoas e o seu bem estar, uma modificação de seu comportamento. Entre estes, destacam-se as fontes de emissões de chaminés de defumadores. Estas não têm, na maioria dos casos sistemas de tratamento de gases, enviando muitos compostos que causam maus odores e também muitos particulados diretamente a atmosfera.
2

Avaliação de bactérias provenientes de um biofiltro de tratamento de vapores de gasolina

Andrade, Daniela Marques January 2008 (has links)
Dissertaçao (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Ambiental. / Made available in DSpace on 2012-10-23T21:23:02Z (GMT). No. of bitstreams: 1 258390.pdf: 2500765 bytes, checksum: 3c48a14276f288a91d5bd7ea177d85db (MD5) / Em todo o mundo a preocupação em relação à poluição atmosférica é crescente, mais especificamente com relação à contaminação por substâncias com características de toxicidade e persistência que as tornam perigosas à saúde humana, às plantas e aos animais. A indústria do petróleo e o uso de seus derivados contribuem significativamente na liberação dos compostos orgânicos voláteis. A problemática ambiental da presença de compostos voláteis na atmosfera deve-se ao fato de alguns serem tóxicos, apresentarem forte odor e estarem envolvidos com chuva ácida, smog fotoquímico e efeito estufa. Os tanques de gasolina representam uma grande fonte de emissões atmosféricas, com perdas de 65,64 t.ano-1. O vapor da gasolina consiste em uma mistura de aproximadamente 90 hidrocarbonetos voláteis, incluindo cadeias alifáticas, cicloalcanos e aromáticos. Devido ao problema ambiental desses poluentes, torna-se necessário medidas de redução e tratamento, tanto por métodos físicoquímico quanto por biológicos. A biofiltração é apondada pela EPA como a melhor tecnologia para tratamento de vapores de gasolina emanados de postos de combustíveis e liberados pelos solos contaminados. Essa tecnologia é baseada na transferência do gás para uma fase líquida dentro de um meio suporte contendo microrganismos, onde ocorrerá a oxidação do poluente liberando CO2 e H2O. Este trabalho teve como objetivo isolar microrganismos provenientes de um biofiltro utilizado para tratamento de vapores de gasolina, estudar a abundância, morfologia e avaliar o crescimento utilizando gasolina como fonte de carbono e energia. Foi realizada a contagem das UFC/g, a avaliação do crescimento em meio líquido com diferentes concentrações de gasolina, a produção de biosurfactantes e a determinação para três bactérias com diferentes habilidades na utilização do substrato. Os resultados mostraram que a microbiota predominate em biofiltros de tratamento de vapores de gasolina é Gram negativa, apresentando contagem da ordem de 1,8x107 UFC/g, o que é coerente para esses sistemas. Também foi verificado que nem todos os isolados que utilizam de alguma forma a gasolina são capazes de produzir biosurfactantes. Entretanto, observou-se uma relação positiva entre a produção de biosurfactantes e o crescimento bacteriano. A presença de bactérias na amostra do suporte do biofiltro que isoladamente não cresceram na presença de gasolina sugere uma co-relação inter-específica com bactérias degradadoras de gasolina. Concentrações de gasolina da ordem de 0,2 % e superiores são tóxicas para micorganismos isolados de zonas do biofiltro que operam com baixas concentrações de vapores de gasolina. Os isolados produtores de biosurfactante apresentam maior crescimento, representando um potencial maior para utilização como inoculantes para sistemas de tratamento de vapores de gasolina.
3

Nitrificação e pré-desnitrificação de esgoto sanitário no sistema

Magri, Maria Elisa January 2009 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Ambiental. / Made available in DSpace on 2012-10-24T07:41:30Z (GMT). No. of bitstreams: 1 266529.pdf: 11868660 bytes, checksum: 852bbb9ccd898233009264e38af41885 (MD5) / O quadro atual dos serviços de esgotamento sanitário no estado de Santa Catarina reforça a necessidade de implantação de unidades de tratamento de esgotos aplicáveis às pequenas coletividades. No estado, 69% dos domicílios possuem como destino de seus esgotos algum tipo de "fossa". Nestes sistemas não são efetivas as remoções de matéria orgânica solúvel, nitrogênio, fósforo e coliformes. Os conceitos abordados pela concepção de saneamento, enquanto saneamento descentralizado, apresentam vantagens quando aplicados neste tipo de situação. Dentro deste contexto, há a necessidade do desenvolvimento de novas alternativas para o tratamento de esgotos de forma descentralizada. Dentro desta perspectiva, este trabalho teve como objetivos o estudo teórico e prático da nitrificação e pré-desnitrificação, além da remoção de matéria orgânica carbonácea, em um sistema composto por um tanque anóxico (TA), um decanto-digestor (DD) e dois biofiltros aerados submersos (BAS) com cascas de ostras como meio suporte. O experimento foi operado durante 300 dias sendo que o DD + BAS foram avaliados em duas fases (1 e 2) bem como o TA (fases A e B). As condições operacionais do DD e BAS foram respectivamente: fase 1 - TDH e COV no DD de 77h e 183gDQO/m3.d; TDH, COV, TAH e relação C:N (DQO:N-NH4+) nos BAS de 15h, 370gDQO/m3.d, 2,6m3/m2.d e 5,0; fase 2 - TDH e COV no DD de 38h e 171gDQO/m3.d; TDH, COV, TAH e relação C:N nos BAS de 7,5h, 372gDQO/m3.d, 5,2m3/m2.d e 3,7. As condições no TA foram respectivamente: fase A - TDH e relação C:N (DQO:N-NO3-) de 8h e 10; fase B - TDH e relação C:N de 4h e 7,4. Além do monitoramento analítico dos efluentes, foram avaliadas as interações entre a fase líquida dos BAS e as cascas de ostras, bem como sua "degradação". Para avaliação comparativa dos dados foi aplicada análise estatística de variância, ANOVA, no software Statistics®. Por meio dos principais resultados coletados, pôde-se concluir que o DD foi mais eficiente na fase 1 (83%) do que na fase 2 (76%) na remoção de SS, enquanto na remoção de DQO os dados coletados em ambas as fases não apresentaram diferença estatística (60% na fase 1 e 57% na fase 2). O BAS1 foi mais eficiente com 98% de remoção de N-NH4+ na fase 2 do que na fase 1 (90%). O BAS2 foi também mais eficiente na fase 2 com 92% de remoção de N-NH4+ do que na fase 1 (90%). Tendo em vista que as condições operacionais da fase 2 proporcionaram melhores eficiências na remoção de N-NH4+ nos BAS, pôde-se concluir que podem ser aplicadas maiores taxas hidráulicas e cargas volumétricas, e menores TDH nos reatores, desde que a relação C:N seja diminuída. Os biofiltros mantiveram uma ótima capacidade de tamponamento, mesmo com uma intensa atividade nitrificante nos reatores, possibilitado pelas cascas de ostras. As cascas sofreram uma perda de massa ao longo do experimento, no entanto, esta perda foi uniforme, ou seja, partes proporcionais de todos os seus constituintes foram perdidas e não somente o carbonato de cálcio, o que garante que ao longo do tempo as cascas não perderão sua função de agente tampão, apesar de diminuírem em volume. O TA foi mais eficiente na desnitrificação na fase A, apresentando uma remoção média de N-NO3- de 88%, quando comparado à fase B onde apresentou 75% remoção de N-NO3-. Pôde-se concluir que para utilização do carbono presente no esgoto doméstico no processo de desnitrificação há a necessidade de adotarem-se relações C:N mais elevadas (>8) e TDH maiores do que 4 horas.
4

Tratabilidade de lixiviado de aterro sanitário por reagente de Fenton consorciado com esgoto sanitário em biofiltro aerado submerso / Treatability of landfill leachate by Fenton\'s reagent combined with submerged aerated bioreactor

Fazzio, Araceli Laranjeira 15 April 2014 (has links)
A disposição ambientalmente adequada dos resíduos sólidos em aterros sanitários requer atenção ao tratamento do lixiviado gerado, que atualmente representa um desafio aos engenheiros, técnicos e pesquisadores da área. Esse trabalho avalia a tratabilidade do lixiviado pelo processo oxidativo avançado Reagente de Fenton, seguido por tratamento consorciado com esgoto sanitário em biofiltro aerado submerso. Os ensaios com Reagente de Fenton foram realizados em escala de bancada, com tempo de duração de 70 min por batelada; constatou-se que a razão mássica mais eficiente em termos de remoção de DQO do lixiviado bruto foi de 2:1 (H2O2:Fe II). Os resultados mostraram que esse tratamento reduziu, em média, 62% da DQO do lixiviado bruto. Entretanto, houve acréscimo do teor de sólidos no efluente e formação de lodo. Quanto ao tratamento consorciado com esgoto sanitário, foram utilizados dois biofiltros aerados submersos - reator controle (R1) e reator R2, que recebia 2% de lixiviado tratado por reagente de Fenton - com vazões de 330 mL/h e 450 mL/h, respectivamente, ambos com tempo de detenção hidráulica de 12 h. No período monitorado e considerando as eficiências médias de remoção de DQO de 75% e 70% e de DBO de 95% e 88% nos reatores R1 e R2, respectivamente, não foi possível concluir se houve tratamento do lixiviado ou apenas diluição. Entretanto, foi observado que a adição de lixiviado comprometeu a eficiência de remoção de matéria orgânica na forma de COD, no biofiltro R2. / The environmentally sound disposal of solid waste in landfills requires attention to the treatment of the leachate generated, which currently represents a challenge to the engineers, technicians and researchers. This research assesses the treatability of leachate by advanced oxidation process Fenton\'s reagent, followed by combined treatment with sewage submerged aerated biofilters. Assays with Fenton\'s reagent were performed in a bench scale, with a duration of 70 min per batch, it was found that the most efficient weight ratio in terms of COD removal of crude leachate was 2:1 (H2O2:Fe II). Results shows that treatment decreased on average 62% of the COD of the crude leachate. However, there was an increase of solids in the effluent and sludge formation. As for combination with sewage treatment, two submerged aerated biofilters were used - control reactor (R1) and R2 reactor, which received 2% of treated leachate by Fenton\'s reagent - with flows of 330 mL/h and 450 mL/h, respectively, both with a hydraulic retention time of 12 h. In the monitored period and considering the average COD removal efficiencies of 75% and 70% of BOD and 95% and 88% in the reactors R1 and R2, respectively, it was not possible to conclude whether there was treatment of leachate or just dilution. However, it was observed that the addition of leachate compromised the efficiency of removal of organic material in the form of COD in the biofilter R2.
5

Tratabilidade de lixiviado de aterro sanitário por reagente de Fenton consorciado com esgoto sanitário em biofiltro aerado submerso / Treatability of landfill leachate by Fenton\'s reagent combined with submerged aerated bioreactor

Araceli Laranjeira Fazzio 15 April 2014 (has links)
A disposição ambientalmente adequada dos resíduos sólidos em aterros sanitários requer atenção ao tratamento do lixiviado gerado, que atualmente representa um desafio aos engenheiros, técnicos e pesquisadores da área. Esse trabalho avalia a tratabilidade do lixiviado pelo processo oxidativo avançado Reagente de Fenton, seguido por tratamento consorciado com esgoto sanitário em biofiltro aerado submerso. Os ensaios com Reagente de Fenton foram realizados em escala de bancada, com tempo de duração de 70 min por batelada; constatou-se que a razão mássica mais eficiente em termos de remoção de DQO do lixiviado bruto foi de 2:1 (H2O2:Fe II). Os resultados mostraram que esse tratamento reduziu, em média, 62% da DQO do lixiviado bruto. Entretanto, houve acréscimo do teor de sólidos no efluente e formação de lodo. Quanto ao tratamento consorciado com esgoto sanitário, foram utilizados dois biofiltros aerados submersos - reator controle (R1) e reator R2, que recebia 2% de lixiviado tratado por reagente de Fenton - com vazões de 330 mL/h e 450 mL/h, respectivamente, ambos com tempo de detenção hidráulica de 12 h. No período monitorado e considerando as eficiências médias de remoção de DQO de 75% e 70% e de DBO de 95% e 88% nos reatores R1 e R2, respectivamente, não foi possível concluir se houve tratamento do lixiviado ou apenas diluição. Entretanto, foi observado que a adição de lixiviado comprometeu a eficiência de remoção de matéria orgânica na forma de COD, no biofiltro R2. / The environmentally sound disposal of solid waste in landfills requires attention to the treatment of the leachate generated, which currently represents a challenge to the engineers, technicians and researchers. This research assesses the treatability of leachate by advanced oxidation process Fenton\'s reagent, followed by combined treatment with sewage submerged aerated biofilters. Assays with Fenton\'s reagent were performed in a bench scale, with a duration of 70 min per batch, it was found that the most efficient weight ratio in terms of COD removal of crude leachate was 2:1 (H2O2:Fe II). Results shows that treatment decreased on average 62% of the COD of the crude leachate. However, there was an increase of solids in the effluent and sludge formation. As for combination with sewage treatment, two submerged aerated biofilters were used - control reactor (R1) and R2 reactor, which received 2% of treated leachate by Fenton\'s reagent - with flows of 330 mL/h and 450 mL/h, respectively, both with a hydraulic retention time of 12 h. In the monitored period and considering the average COD removal efficiencies of 75% and 70% of BOD and 95% and 88% in the reactors R1 and R2, respectively, it was not possible to conclude whether there was treatment of leachate or just dilution. However, it was observed that the addition of leachate compromised the efficiency of removal of organic material in the form of COD in the biofilter R2.
6

Caracterização do efluente de uma vinícola na região do Vale do Rio Peixe/SC e avaliação do seu tratamento por biofiltro aerado submerso

Ortigara, Angela Renata Cordeiro January 2009 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Ambiental / Made available in DSpace on 2012-10-24T21:42:05Z (GMT). No. of bitstreams: 1 265978.pdf: 4440700 bytes, checksum: ba19c197a3b5f29e979a2708b2be6be1 (MD5) / O presente estudo teve como objetivo avaliar as variações na composição quali-quantitativa dos efluentes líquidos gerados por uma vinícola e o comportamento do tratamento destes efluentes em reatores do tipo Biofiltro Aerado Submerso com preenchimento de cascas de ostras. A etapa experimental foi realizada no período de 28/01/2008 a 20/12/2008. Estudou-se o fluxograma do processo produtivo, identificando-se os principais resíduos gerados, a variação do consumo de água e as características do efluente líquido em dois períodos distintos: a safra e a entressafra, além da avaliação do tratamento deste efluente por Biofiltro Aerado Submerso (BAS). Os principais subprodutos gerados pela atividade são provenientes da uva (engaço, cascas, sementes, borra) e do processo produtivo (bentonite e terras de filtração). A vínicola apresentou um índice de consumo de 1,78 L de água/L de vinho produzido. A Amostragem Composta apresentou valores de 9.090 mgDQO/L para o período da safra e para a entressafra, 8.260 mgDQO/L. As atividades que apresentaram valores mais elevados de consumo de água e de geração de carga orgânica foram a lavagem de filtros, pipas, prensas e pisos. De acordo com avaliação, o efluente apresentou pH médio de 4,5 e alcalinidade de 60,4 mgCaCO3/L, e concentrações de carbono, nitrogênio e fósforo inadequadas ao tratamento biológico (100/0,25/0,25). Para avaliar a tratabilidade do efluente vinícola pelo BAS, preenchido com casca de ostra, foram utilizados dois reatores em escala laboratorial: um alimentado com o efluente da safra (BAS 1) e o outro com efluente da entressafra (BAS 2). Para a realização dos testes, o efluente homogeinizado teve suas características avaliadas, e o balanço nutricional ajustado com a adição de cloreto de amônio (NH4CL) e fosfato de potássio bibásico (K2HPO4). Foram considerados três períodos operacionais com duração de 5 semanas cada e com o mesmo tempo de detenção hidráulica (24 horas). No Período 1, a alimentação dos reatores foi descontínua com cargas variávies, no Período 2, manteve-se a alimentação descontínua e as cargas abaixo de 5 kgDQO/m³ e no Período 3, o reator foi alimentado de forma contínua com cargas abaixo de 5 kgDQO/m³. O meio filtrante foi capaz de conferir alcalinidade ao sistema e aumentar o pH nos reatores para valores de aproximadamente 6,7. O Período 3 apresentou as melhores eficiências de remoção de DQO, 90% para o BAS 1 e 82% para o BAS 2. Não ocorreu remoção média de nitrogênio no BAS 1, e no BAS 2, apenas 31%. A remoção máxima de fósforo foi de 58% e 53% nos BAS 1 e 2, respectivamente. Quanto aos metais, apenas os valores médios de cobre nos efluentes dos biofiltros estavam acima de 0,5 mg/L, valor máximo permitido pelo Decreto Estadual 14.250/1981. Constatou-se que o emprego de BAS, operando em fluxo contínuo pode ser uma alternativa para o tratamento de efluentes vinícolas na região de estudo.
7

Avaliação de um biofiltro piloto para desodorização de compostos orgânicos do setor petroquímico

Souza, Marcos Lopes de January 2007 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Ambiental / Made available in DSpace on 2012-10-23T14:56:07Z (GMT). No. of bitstreams: 0 / A poluição odorífera tem gerado diversos conflitos entre as fontes de emissão e a população afetada. Odores desagradáveis são provenientes de inumeras fontes, dentre as quais a indústria petrolífera. Os parques industriais de derivados de petróleo emitem diversos compostos compostos orgânicos voláteis (COV), muitos de natureza odorífera. A biofiltração, a qual é uma tecnologia de baixo custo para desodorização, foi utilizada para reduzir odores de gasolina comercial gerados a partir de uma fonte sintética. Um biofiltro em escala piloto utilizando turfa como material suporte, foi monitorado durante 140 dias a uma taxa de aplicação superficial (TAS) de 62 m3/m2.h e um tempo de contato (TC) de 52 segundos. A umidade mantida no leito variou entre 50 e 60% e o pH médio foi de 5,4. As amostragens semanais do gás odorante bruto e do gás tratado permitiram avaliar a eficiência do sistema através de análises olfatométricas e análises físico-químicas. Através da olfatometria, um corpo de jurados composto entre seis e dez pessoas avaliaram os seguintes parâmetros relativos a um estudo de impacto de odor: concentração, intensidade, qualidade, hedonicidade e nível de incômodo. As análises físico-químicas foram realizadas por uma unidade de cromatografia gasosa acoplada a um espectrômetro de massa. Estas análises permitiram a identificação dos compostos presentes nas amostras pré e pós-tratamento, bem como a avaliação da redução da concentração e do número de compostos proporcionada pela biofiltração. Após 140 dias de operação a redução da concentração do odor foi de 87%, a intensidade do odor da amostra tratada foi fraca, a hedonicidade foi agradável e o nível de incômodo foi nulo. As concentrações de benzeno, tolueno, etilbenzeno e xilenos foram reduzidas respectivamente em :89,98%, 46,43%, 25,0% e 68,60%. A quantidade de compostos foi reduzida significativamente de 65 para a amostra contendo o gás odorante bruto para 16 compostos presentes na amostra tratada. A biofiltração mostrou-se uma alternativa promissora no combate às emissões odoríferas provenientes do setor petrolífero. Malodorous atmospheric emissions have been the cause of a number of conflicts between their emission sources and the affected population. There are many different sources of odor emissions, and petrochemical companies are an example of such. Petroleum-derived fuels are formed by a large number of volatile organic compounds (VOC), and many of those are odoriferous. The biofiltration, which is a technology of low cost for deodorization, was used to reduce commercial gasoline odors generated from a synthetic source. One biofilter in pilot-scale using turf as material support was monitored during 140 days to a tax of superficial application (TAS) of 62 m3/m2.h and a time of contact (TC) of 52 seconds. The humidity kept in the bed varied between 50 and 60% and the pH average were of 5,4. Weekly samples of raw and treated gas had allowed to evaluate the efficiency of the system through olfactometric and physicalchemical analyses. Through the olfactometry, an olfactometric jury composed between six and ten people had evaluated the following relative parameters to a study of odor impact: concentration, intensity, quality, hedonic character, and annoyance level. The analyses physical-chemical had been carried through by chromatography unit coupled with a mass spectrometer. The physical-chemical analyses were conducted in order to identify the compounds present in the samples collected before and after treatment, and to evaluate the concentration reduction of the odorous compounds through biofiltration. After 140 days of operation, the observed odor concentration reduction was of 87%. The treated gas had weak odor intensity, a pleasant hedonic value and the annoyance level was inexistent. The benzene, toluene, ethyl benzene and xylene concentrations were reduced in 89,98%, 46,43%, 25,0% and 68,60%, respectively. The amount of compounds was reduced significantly of 65 for the sample contends the raw gas for 16 compounds gifts in the treated sample. The biofiltration revealed a promising alternative in the treatment the odoriferous emissions proceeding from the petrochemical sector.
8

Emprego de biofiltro de pedra para remo??o de microalgas e s?lidos suspensos de efluentes de lagoas de estabiliza??o

Queiroz, Mois?s Andrade de Farias 28 February 2014 (has links)
Made available in DSpace on 2014-12-17T15:03:33Z (GMT). No. of bitstreams: 1 MoisesAFQ_DISSERT.pdf: 1322817 bytes, checksum: d69733a37de991cb265f0cf0939bee27 (MD5) Previous issue date: 2014-02-28 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / This research evaluated the microalgae removal produced in a stabilization pond system using biofilters as post-treatment, besides characterizing the effluents of stabilization ponds and filters in relation to concentrations of algal biomass (chlorophyll a and suspended solids), organic matter (BOD and COD), total phosphorus, orthophosphate, pH and dissolved oxygen, and tried to correlate physicochemical parameters with chlorophyll "a". It was held at the Ponta Negra ETE which is constituted by three stabilization ponds, with a primary facultative pond and two of maturation. For the algae removal were used two submerged bio-filters: the filter FPF (Facultative Pond Filter), fed with facultative pond effluent; and the filter MPF (Maturation Pond Filter), fed with second maturation pond effluent. The filling material of both filters was predominantly gravel no. 2, although it contains portions of gravel no. 1 and no. 3. The filters operating conditions were bad, they were nearly 10 years without maintenance, without cleaning or removal of sludge since the time of its construction, and part of the filling material may be obstruct. Despite poor operating conditions were obtained satisfactory results, in level of posttreatment. Removal efficiencies in relation to BOD and COD were 7 and 25% in FPF and 9 and 19% and in MPF, respectively. In relation to TSS efficiencies in MPF and FPF were 37 and 20%, respectively. As for the chlorophyll "a" removal, the FPF efficiency was 44% and the MPF was 40%. There was 50% of consumption of dissolved oxygen, on average, within the filters. Two profiles were performed in the filters, and it was possible to conclude that variations throughout the day were not statistically significant, and that, regardless of the time of collection, they would have the same representation comparing to the time of data collection (7 am) and the daily average, although individual variations throughout the day have been shown to be significant. Another important observation is that the correlations between Chlorophyll a and TSS were bigger and more significant in the effluent of the filters than in the effluent of the ponds / A pesquisa avaliou a remo??o das microalgas produzidas em um sistema de lagoas de estabiliza??o utilizando biofiltros como p?s-tratamento, al?m de caracterizar os efluentes de lagoas de estabiliza??o e dos filtros no tocante ?s concentra??es de biomassa algal (clorofila a e s?lidos suspensos), mat?ria org?nica (DBO e DQO), ortofosfato, f?sforo total, pH e oxig?nio dissolvido, e buscou correlacionar os par?metros f?sico-qu?micos com a clorofila a . Foi realizada na ETE Ponta Negra que ? constitu?da por tr?s lagoas de estabiliza??o, sendo uma lagoa facultativa prim?ria e duas de matura??o. Para a remo??o das algas, foram utilizados dois biofiltros submersos: o filtro FLF -alimentado com efluente da lagoa facultativa; e o filtro FLM - alimentado com efluente da segunda lagoa de matura??o. O material de enchimento de ambos os filtros foi predominantemente brita n? 2, apesar de conter por??es de brita n? 1 e n? 3. As condi??es operacionais dos filtros eram p?ssimas, pois estavam h? quase 10 anos sem manuten??o, sem limpeza ou remo??o do lodo desde a ?poca da constru??o, podendo parte do material de enchimento estar colmatado. Apesar das condi??es operacionais prec?rias foram obtidos resultados satisfat?rios, em n?vel de p?s-tratamento. As efici?ncias de remo??o em rela??o ? DBO e DQO foram de 7 e 25% no FLF e 9 e 19% no FLM, respectivamente. Em rela??o aos SST as efici?ncias no FLF e FLM foram de 37 e 20%, respectivamente. Quanto ? remo??o de clorofila a , a efici?ncia no FLF foi de 44% e no FLM foi de 40%. Houve o consumo de 50% do oxig?nio dissolvido, em m?dia, no interior dos filtros. Foram realizados dois perfis nos filtros, e foi poss?vel concluir que as varia??es ao longo do dia n?o foram estatisticamente significativas, e que, independentemente do hor?rio da coleta, teriam a mesma representatividade ao comparar com o hor?rio da coleta da pesquisa (7 horas da manh?) e a m?dia di?ria, embora as varia??es pontuais ao longo do dia tenham se mostrado expressivas. Outra importante observa??o foi que as correla??es entre Clorofila a e SST foram maiores e mais significativas nos efluentes dos filtros do que nos efluentes das lagoas

Page generated in 0.0503 seconds