• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 36
  • Tagged with
  • 37
  • 37
  • 23
  • 17
  • 15
  • 14
  • 14
  • 9
  • 9
  • 9
  • 8
  • 7
  • 7
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Inclusão de compósitos cimentícios em blocos estruturais cerâmicos com foco em conforto térmico

Carvalho, Milene January 2017 (has links)
Materiais aplicados na construção civil são importantes para fornecer segurança e conforto às pessoas. Quanto mais adequadas as propriedades térmicas, menos energia é necessária para aquecer ou resfriar uma área construída. A NBR 15575:2013 - Desempenho de Edificações Habitacionais, padronizou desempenhos térmicos para construções. Os blocos estruturais cerâmicos atendem o padrão mínimo, porém acredita-se que seu desempenho possa ser melhorado utilizando materiais de características isolantes dentro de seus furos verticais. Assim, o objetivo deste trabalho é investigar compósitos de matriz cimentícia com agregados leves para o aprimoramento térmico de blocos estruturais cerâmicos. Para o estudo, quatro corpos de prova foram produzidos preenchendo o vazado dos blocos com compósitos de matriz cimentícia utilizando 80% agregados leves (argila expandida, vermiculita, poliestireno expandido (EPS) e perlita expandida), 20% de cimento, além de uma amostra preenchida com graute estrutural que é comumente utilizado em edificações de alvenaria estrutural. Também foram produzidos corpos de prova com os compósitos, para a análise de massa específica, microscopia, resistência à compressão, absorção de água e desempenho térmico medido por termografia. Nos blocos, analisou-se massa final preenchido, absorção de água e desempenho térmico. No estudo termográfico, os blocos preenchidos foram comparados ao bloco cerâmico vazado padrão. Concluiu-se que o preenchimento dos vazados dos blocos com todos os compósitos leves e com o graute estrutural proporcionou um desempenho térmico melhor que o do bloco padrão, se destacando o EPS como melhor desempenho. O desempenho térmico dos prismas de compósitos confirmou o que foi observado nos corpos de prova de blocos. Assim foram feitos novos corpos de prova maximizando o teor de EPS para 85% e 90%. A análise térmica destas amostras apresentou melhor resultado para EPS 90%. O aumento do teor de EPS diminuiu a resistência à compressão e aumentou a absorção de água, porém, como o foco é o desempenho térmico e o bloco preenchido com o compósito EPS (90%) atende as características normativas, esta pode ser uma solução interessante. / Materials applied in civil construction are important to provide security and comfort to people. The more appropriate the thermal properties are, the less energy it is necessary to provide heat or cold to a constructed area. The NBR 15575:2013 standard, which deals with the Performance of Residential Constructions, has standardized thermal performances for buildings. Structural ceramic blocks meet the minimum standard, but it is believed that their performance can be improved by means of materials with isolating characteristics within their vertical holes. Thus, the aim of this paper is to investigate cementitious matrix composites with lightweight aggregates for thermal improvement of ceramic structural blocks. For the study, four specimens were produced by filling the hollow spaces of the blocks with cementitious matrix composites using 80% of lightweight aggregates (expanded clay, vermiculite, expanded polystyrene – EPS –, and expanded perlite), and 20% of cement. These were compared to a sample filled with structural grout, which is commonly used in structural masonry buildings. Specimens were also produced with the composites for specific mass analysis, microscopy, compression resistance, water absorption and thermal performance measured by thermography. In the blocks, the final, filled weight was analyzed, as well as water absorption and thermal performance. In the thermographic study, the filled blocks were compared to standard ceramic hollow blocks. It was concluded that filling the hollow spaces of the blocks with all the lightweight composites and structural grout provided a better thermal performance than that of standard blocks, highlighting EPS as having the best performance. Thermal performance of the composite prisms confirms what was observed in the block specimens. Thus, new specimens were made maximizing the EPS content to 85% and 90%. Thermal analysis of these samples presented better results for EPS 90%. The increase in the EPS content decreased compression resistance and increased water absorption. However, as the focus is thermal performance and as the block filled with EPS composite (90%) meets the requirements of the standard, this may be an interesting solution.
22

Influência da aderência graute/bloco cerâmico estrutural no comportamento mecânico do conjunto

Guarnieri, Leonel de Oliveira January 2017 (has links)
Atualmente, a alvenaria estrutural é utilizada em empreendimentos habitacionais de larga escala, nos quais as exigências de racionalização, controle, rapidez e custo são mais bem contemplados pelo sistema. No Brasil, existem empreendimentos de até 16 pavimentos construídos com blocos de alta resistência e alto controle tecnológico. A construção de edificações com maiores alturas exige o aumento da capacidade de absorção de esforços de compressão e tração. Para isso, são inseridas barras de aço nos vazados dos blocos e consolidadas com graute, a fim de aumentar a capacidade portante do conjunto. Entretanto, a influência da aderência graute/ bloco cerâmico no comportamento mecânico da alvenaria estrutural ainda é uma dúvida, visto que a NBR 15812 - 1 (ABNT, 2010) não especifica um valor de resistência para aderência graute/ bloco cerâmico, somente para graute/ aço. Frente a essa constatação, a presente pesquisa tem o objetivo de avaliar a influência da aderência graute/ bloco cerâmico estrutural no comportamento mecânico do conjunto, para determinar um valor de tensão de aderência que possa contribuir com a NBR 15812-1 (ABNT, 2010) Para isso, foram utilizados quatro tipos de blocos cerâmicos, com variação da geometria interna dos vazados e resistência mecânica à compressão. O graute foi padronizado em somente uma resistência, sendo essa de 30 MPa. Para desenvolvimento da pesquisa, inicialmente foi realizada a caracterização dos materiais e, posteriormente, realizados ensaios de push-out, resistência à compressão de blocos preenchidos com graute e microscopia óptica. Os resultados revelaram que a aderência graute/ bloco cerâmico estrutural é superior à resistência mecânica à tração do bloco cerâmico, e que a ruptura do conjunto ocorre primeiramente no bloco. Os resultados também constataram aumento da resistência mecânica à compressão axial nos blocos preenchidos com graute. / Currently, structural masonry is used in large-scale housing projects, in which the requirements of rationalization, control, speed and cost are better covered by the system. In Brazil there are projects of up to 16 floors built with high resistance and high technological control blocks. The construction of buildings with higher heights requires the increase of the capacity of absorption of compression and traction forces. For this, steel bars are inserted into hollow blocks which are then consolidated with grout in order to increase the load-bearing capacity of the assembly. However, the influence of ceramic block/grout adhesion in the mechanical behavior of structural masonry is still unknown since the NBR 15812-1 (ABNT, 2010) standard does not specify a resistance value for grout/ceramic block adhesion, only for grout/steel adhesion. In view of this finding, the present research has the objective of evaluating the influence of the structural ceramic block/grout adhesion on the mechanical behavior of the assembly in order to determine a value of adhesion tension that can contribute to the NBR 15812-1 (ABNT, 2010) standard For this purpose four types of ceramic blocks with a variation in the internal geometry of the hollow spaces and mechanical strength to compression were used. Grout was standardized in only one strength of 30 MPa. For development of the research, initially the characterization of the materials was performed and, subsequently, the tests of push-out and compressive strength of grout-filled blocks and light microscopy. The results showed that the grout/ceramic block adhesion is superior to the mechanical tensile strength of the ceramic block and, therefore, the rupture of the assembly will occur first in the block. The results also showed a significant increase of the mechanical resistance to axial compression in blocks filled with grout.
23

Efeito da temperatura de queima de blocos cerâmicos sobre a resistência de aderência à tração de revestimentos de argamassa / Effect of production burning temperature of ceramic blocks and its influence in the tensile bond strength of mortar renderings under ceramic block walls

Pagnussat, Daniel Tregnago January 2013 (has links)
Muitos pesquisadores têm procurado analisar a questão dos mecanismos de aderência entre argamassas de revestimento e substratos porosos, das mais variadas formas. Este trabalho insere-se nessa mesma linha de pesquisa. A partir dos referenciais teóricos pesquisados, definiu-se como objetivo principal desta tese contribuir para o entendimento de alguns dos fatores intervenientes no fenômeno de aderência entre substratos cerâmicos e argamassas de cimento Portland. O enfoque proposto visou identificar, prioritariamente, a influência de substratos cerâmicos com diferentes temperaturas de queima (e conseqüentemente diferentes padrões de porosidade e absorção de água), e sua relação com a resistência de aderência adquirida pelo sistema de revestimento, sob condições específicas. Foi proposto um programa experimental onde uma argamassa com características específicas foi assentada em blocos cerâmicos lisos ou com estrias verticais. Esta argamassa revestiu blocos com diferentes capacidades de absorção de água, obtidas através da queima dos mesmos em diferentes temperaturas: 700, 800, 900 e 1000°C. Variaram-se também as condições na interface entre argamassa e substrato: sem nenhum tratamento da área de contato, ou então reduzindo o potencial contato superficial e consequentemente a penetração de água/pasta nos poros em 50% da área do bloco cerâmico. Foram mapeadas as principais propriedades dos blocos cerâmicos que se alteraram ou mantiveram com o processo de queima, de modo a verificar sua influência sobre os resultados de aderência à tração das argamassas neles assentados. Os resultados demonstram que a alteração da temperatura de queima dos blocos, bem como a introdução de restrições para a absorção de água e/ou pasta dos blocos, variaram consideravelmente os resultados de aderência à tração dos revestimentos. Há uma relação significativa entre a estrutura de poros do substrato, em função da temperatura de queima, e a resistência de aderência do sistema de revestimento. / Over the centuries, mortar renderings have been considered a traditional building technique. However, even recent technologic improves couldn't eliminate some pathologies problems such as detachments. In Brazil, particularly, many researchers have been studying the adhesion mechanisms between mortar renderings and porous substrates in different ways. This work is part of this interest point. After the theoretical research realized, the main objective of this doctoral thesis consisted to contribute to the understanding of bond strength phenomenon, specially of some factors involved between ceramic substrates and Portland cement mortars. The proposed approach aimed to identifying the influence of ceramic substrates with different firing temperatures (and therefore with different porous surface and water absorption), and its relationship to bond strength acquired by the mortar rendering system under specific conditions. A Lime-Portland Cement mortar with specific characteristics was applied on smooth or grooved surfaces of ceramic blocks. The firing temperature of production of these ceramic blocks was 700, 800, 900 and 1000 ° C. Furthermore, the interface conditions between mortar and ceramic substrate also was varied: without any contact surface treatment, or reducing potential contact surface (and thus water/paste penetration) in the 50% area of ceramic blocks. After, had been identified the main properties of ceramic blocks that have changed or remained after the firing process, so check their influence on the results of tensile bond strenght of mortars settled on them. The results show that with changing the firing temperature of the blocks as well as the introduction of pore sealing areas to the absorption of water and / or binder in blocks surfaces, the tensile bond strength of mortar renderings also varied considerably. There is a significant relationship between pore structure of the ceramic substrate, depending on the firing temperature, and the bond strength of the mortar rendering system.
24

Contribuição ao estudo de pórticos de concreto armado preenchidos com alvenaria de blocos cerâmicos

PITANGA, Marcelo de Andrade 30 November 2017 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-07-31T20:17:31Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Marcelo de Andrade Pitanga.pdf: 6559790 bytes, checksum: b9790d38776966b8704b6f37cfc61467 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-07-31T20:55:02Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Marcelo de Andrade Pitanga.pdf: 6559790 bytes, checksum: b9790d38776966b8704b6f37cfc61467 (MD5) / Made available in DSpace on 2018-07-31T20:55:02Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Marcelo de Andrade Pitanga.pdf: 6559790 bytes, checksum: b9790d38776966b8704b6f37cfc61467 (MD5) Previous issue date: 2017-11-30 / Edifícios de concreto armado são formados por pórticos que são geralmente preenchidos pela alvenaria de vedação de blocos cerâmicos. O comportamento estrutural do pórtico preenchido com alvenaria é diferente daquele sem o preenchimento. Adicionalmente, quando se observa uma célula isolada do pórtico preenchido, a força lateral induzida pela ação do vento pode levar a um quadro de degradação da estrutura, inclusive, com a ocorrência de fissuras nos blocos cerâmicos, nas juntas de argamassa e no pórtico. Este trabalho tem como objetivo estudar o comportamento estrutural dos pórticos preenchidos isolados de um andar e um vão, utilizando-se o software comercial ANSYS baseado no Método dos Elementos Finitos (MEF). O comportamento genérico do pórtico preenchido será analisado, mostrando-se a formação da biela de compressão, o esmagamento dos cantos comprimidos e a fissuração da diagonal comprimida. Em seguida serão realizadas análises numéricas de 54 modelos, entre pórticos simples e preenchidos com alvenaria. Como resultados, são apresentados a comparação entre curvas força-deslocamento, a verificação da capacidade resistente, a plastificação da biela de compressão, o cálculo da largura da diagonal equivalente, o estado de fissuração dos modelos e a calibração do modelo da barra diagonal equivalente via elementos finitos. Conclui-se que o mecanismo da interação na interface do pórtico com a alvenaria e consequente formação da biela de compressão modifica substancialmente o comportamento dos pórticos preenchidos. Ressalta-se que os resultados dessa pesquisa precisam ser ampliados para que possam ser adotados no projeto estrutural de edifícios altos de múltiplos pavimentos. / Reinforced concrete buildings are made of frames which are usually filled with tile blocks masonry walls. The structural behavior of the masonry filled frame is different from those not fulfilled. In addition, while analyzing one isolated cell in the filled frame, lateral force induced by wind action might lead to an environment of structural degradation, besides the occurrence of cracks on tile blocks, mortar joints and frame. The aim of this study is to learn about the structural behavior of one-store and one-bay infilled frames, for which commercial software ANSYS was used based on the Finite Element Method. The generic behavior of the infilled frame was analyzed by presenting the formation of the compression rod, the crushing of the compressed corners and the cracking of the compressed diagonal. Subsequently numerical analysis were conducted in 54 models, among simple frames and infilled frames. The results are demonstrated by comparing force-displacement curves, evaluation of resistant capacity, plasticizing of compression rod, calculation of width of equivalent diagonal, cracking state of the models and the calibration of the equivalent diagonal bar model using finite elements. It is concluded that the interaction mechanism at the interface of the frame with the masonry and consequent formation of the compression rod substantially modifies the behavior of the infilled frames. It should be emphasized that the results of this research need to be expanded so that they can be adopted in the structural design of high-rise multi-storey buildings.
25

Influência da argamassa de revestimento na resistência à compressão axial em prismas de alvenaria resistente de blocos cerâmicos

Mota, João Manoel de Freitas January 2006 (has links)
Made available in DSpace on 2014-06-12T17:41:46Z (GMT). No. of bitstreams: 2 arquivo6536_1.pdf: 2925268 bytes, checksum: 1a88abdca6861e28726ad5e49dcf4c70 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2006 / A partir da década de 70, iniciou-se a construção, em larga escala, de edifícios tipo caixão , concebidos de alvenaria resistente com até quatro pavimentos, na Região Metropolitana do Recife. Sabe-se que essas construções foram executadas sem fundamentação tecnológica e normas técnicas pertinentes, sejam nacionais ou internacionais. Verifica-se que, nessas construções, os materiais utilizados, fundamentalmente os blocos cerâmicos vazados destinados à vedação, assentados com furos na horizontal, não apresentam requisitos de desempenho necessários para serem considerados estruturais. O cálculo da resistência à compressão das paredes dos edifícios construídos com este tipo de alvenaria mostra que são insuficientes para resistir aos esforços a que se destinam, especialmente nos pavimentos inferiores. Isso significa que edifícios construídos e habitados não passam em critérios normativos de estabilidade. Faz-se assim necessário investigar aspectos próprios do processo, buscando aduzir possíveis aspectos influenciadores na resistência à compressão. Leve-se em consideração que centenas de edifícios se encontram em operação. Este trabalho tem por objetivo estudar a influência do revestimento na resistência à compressão axial das paredes de alvenaria de vedação, empregadas com função estrutural, utilizando blocos cerâmicos vazados assentados com furos na horizontal. Foram ensaiados prismas, buscando estabelecer conhecimento necessário do comportamento e intensidade da contribuição do revestimento a essa propriedade mecânica, que se mostra de extrema relevância para estabilidade da edificação. Verificou-se que a argamassa de revestimento contribui, de forma substancial, na resistência à compressão axial desse tipo de alvenaria. Desta maneira, são necessárias investigações experimentais objetivando a reabilitação destas edificações, principalmente no caso específico da Região Metropolitana do Recife, onde se têm milhares de edifícios construídos com esse processo construtivo
26

ANÁLISE DO COMPORTAMENTO DE PRISMAS GRAUTEADOS DE ALVENARIA ESTRUTURAL CERÂMICA / ANALYSIS OF THE BEHAVIOR OF GROUTED CLAY PRISMS FOR STRUCTURAL MASONRY

Grohmann, Leandro Zampieri 24 February 2006 (has links)
The main purpose of this thesis is to evaluate the behavior of clay prisms grouted, partially grouted and ungrouted under compression loads in order to analyze the influence and performance of the grout, as well as to seek how to optimize its applicability. For that, testing was done with different grouts and grouting ratios. The testing was done in 120 prisms under simple axial compression load, where sets of prisms had two different types of mortar (A1 and A2), three different grouts (G1, G2 e G3) and four different ratios of grouted cavities (0%, 33%, 66% e 100%). For this testing, all the materials and components were previously characterized. Based on experimental data, the analysis of the results was done taking into account the different sets of prisms grouping them according to their mortar, grout and grouting ratio. The variance analysis for the sample was done in order to prove the existence of significant differences among the various group combinations. It was also performed a comparison among the data found and results gathered by other researchers. Another investigation was done regarding the fracture behavior of prisms and the influence of interactions among block, mortar and grout was observed. Through the analysis of the results, some of the conclusions regarding the behavior of prisms were: the importance of the mortar s strength for the compression strength of the prisms; the increase in the strength of the grout does not indicate a significant increase in the prisms strength; the significant increase in the prisms strength is noticed only when the totality of the prisms cavities are grouted. Overall, the use of masonry walls with partially grouted cavities is efficient if properly used. For that, the types of grout and mortar must be suitable to and in accordance with the mechanical behavior of the blocks used. / Este trabalho tem como objetivo principal avaliar o comportamento de prismas de blocos cerâmicos grauteados, parcialmente grauteados e não-grauteados sob a ação de cargas de compressão para que se possa analisar a influência e o desempenho do graute e buscar sua otimização. Para tanto, foram realizados ensaios experimentais de prismas com diferentes tipos de grautes e porcentagens de grauteamento. O método de pesquisa compreendeu o ensaio de compressão axial simples de 120 prismas contrafiados de blocos cerâmicos com a utilização de dois tipos de argamassa (A1 e A2), três tipos de grautes (G1, G2 e G3) e quatro diferentes porcentagens de células grauteadas (0%, 33%, 66% e 100%), onde todos os materiais e componentes empregados foram previamente caracterizados. Com base nos dados experimentais foi realizada uma análise dos resultados obtidos, por tipo de argamassa, tipo de graute e porcentagem de grauteamento utilizados. Para comprovar a existência de diferenças significativas entre as várias combinações de prismas ensaiados, foi feita a análise de variância da amostra ensaiada. De posse destes resultados, foram feitas comparações com resultados obtidos por outros autores. Também observou-se, neste trabalho, os modos de ruptura dos prismas e foi constatada a influência das interações entre bloco, argamassa e graute neste comportamento. Através da análise dos resultados pôde-se chegar a conclusões sobre o comportamento dos prismas, como: a importância da resistência da argamassa na resistência à compressão dos prismas; um aumento não significativo de resistência dos prismas ao aumentar a resistência do graute; e um ganho efetivo de resistência dos prismas somente ao terem a totalidade de suas células grauteadas. De modo geral, conclui-se que a utilização do grauteamento parcial em painéis de alvenaria é eficiente desde que seja utilizado de forma adequada, havendo compatibilização da dosagem de traços de grautes e argamassas com as características mecânicas dos blocos utilizados.
27

RESISTÊNCIA À COMPRESSÃO DE PRISMAS PREENCHIDOS COM ARGAMASSA / GRAUTE / PRISMS MECHANICAL EVALUATION FILLED WITH MORTAR / GROUT THE COMPRESSION

Marco, Carlos Eduardo Giacomini de 10 March 2016 (has links)
This work has as main objective to analyze the mechanical behavior of prisms run with ceramic bricks and filled with mortar or grout, checking their influence when subjected to centric compression. An experimental program consists of four different types of prisms was developed. They were used for making the prisms blocks of three different Manufacturers. The ceramics were randomly named as Manufacturer 1 Manufacturer 2 and Manufacturer 3, manufacturers have provided the following resistance of structural blocks: Manufacturer 1 - fbk (A) 6 MPa, Manufacturer 2 - fbk (E) 7 MPa and fbk (C) 15 MPa Manufacturer 3 - FBK (B) and 6 MPa FBK (D) 15 MPa.The prisms were molded with industrialized mortar. Each prism type with its respective resistors blocks were molded as follows: hollow prism, prisms filled with grout (the larger castings), the same used in the settlement, and prisms filled with grout, totaling 320 prisms, which were subjected to tests to simple axial compression. The results were analyzed statistically by the Tukey test at 5% significance level. It was concluded that the grout used not added significant increase in resistance to the prisms, the study can not say whether it is possible or not to replace the grout by mortar, to fill the cast, as well as adequate strength of the mortar used in filling It should be further studied. / Este trabalho tem como objetivo principal analisar o comportamento mecânico de prismas executados com blocos cerâmicos e preenchidos com argamassa ou graute, verificando a sua influência quando submetidos à compressão centrada. Foi desenvolvido um programa experimental composto por quatro diferentes tipos de prismas. Foram utilizados para confecção dos prismas blocos de três diferentes cerâmicas. As cerâmicas foram nomeadas aleatoriamente como Fabricante 1, Fabricante 2 e Fabricante 3. Os fabricantes forneceram as seguintes resistências de Blocos Estruturais: Fabricante 1 fbk(A) 6 MPa, Fabricante 2 fbk(E) 7 MPa e fbk(C) 15 MPa, Fabricante 3 fbk(B) 6 MPa e fbk(D) 15 MPa. Os prismas foram moldados com argamassa industrializada. Cada tipo de prisma, com suas respectivas resistências de blocos, foi moldado da seguinte forma: prismas ocos, prismas preenchidos com argamassa (nos vazados maiores), a mesma utilizada no assentamento; e prismas preenchidos com graute, totalizando 320 prismas, os quais foram submetidos a ensaios à compressão axial simples.Os resultados foram analisados estatisticamente através do Teste de Tukey com nível de significância de 5%. Concluiu-se que o graute utilizado não agregou significativo acréscimo de resistência aos prismas. Pelo estudo realizado não se pode afirmar se é possível ou não substituir o graute pela argamassa, no preenchimento dos vazados, assim como a resistência adequada da argamassa com uso no preenchimento deve ser novamente estudada.
28

Avaliação da ação da florescência em cerâmica vermelha com adição de lodo de fosfatização

Bersch, Rosângela Andréia 03 March 2011 (has links)
Submitted by Nara Lays Domingues Viana Oliveira (naradv) on 2015-08-05T19:25:05Z No. of bitstreams: 1 RosangelaBerschEngCivil.pdf: 4573683 bytes, checksum: bcd59ec2871283c130461a507acc1ace (MD5) / Made available in DSpace on 2015-08-05T19:25:05Z (GMT). No. of bitstreams: 1 RosangelaBerschEngCivil.pdf: 4573683 bytes, checksum: bcd59ec2871283c130461a507acc1ace (MD5) Previous issue date: 2011-03-03 / PROSUP - Programa de Suporte à Pós-Gradução de Instituições de Ensino Particulares / A cristalização de sais é uma patologia importante e freqüentemente observada em alvenarias. No entanto é ainda uma das patologias menos compreendidas. O objetivo deste trabalho é justamente avaliar o impacto da florescência de sais solúveis em corpos-de-prova cerâmicos desenvolvidos com lodo de fosfatização. Para tanto, foram moldados corpos-de-prova com 0; 2,5% e 5% (em peso) de lodo, os quais foram sinterizados a temperatura de 750ºC, 850ºC, 950ºC e 1050ºC. Os corpos-de-prova foram divididos em dois grupos, dos quais um foi mantido sob temperatura e umidade controladas e o outro, submetido a ciclos de molhagem e secagem. Os grupos foram ensaiados em 1, 30, 110 e 180 dias. Foram submetidos à análise de imagem (através de Lupa binocular, software gráfico e microscopia eletrônica de varredura), absorção de água por capilaridade, porosimetria por intrusão de mercúrio e resistência à flexão. Para análise química e das fases presentes, foram realizadas análises via difração de raios-x, fluorescência de raios-x e espectrometria de emissão atômica. Os resultados indicam a presença de alumínio, silício, cálcio, potássio, enxofre, ferro e manganês, dos quais se destaca a combinação entre o enxofre e cálcio. Desta forma, a gipsita é tida como provável responsável pelos sais solúveis, cujos depósitos foram encontrados sob variada extensão e intensidade, predominado nos corposde-prova com adição de lodo. A variação da porosidade e a aparente diminuição do coeficiente de absorção capilar ao longo dos ensaios podem ser associadas aos processos de solubilização e recristalização da gipsita. No tempo de ciclagem estudado, o fenômeno não apresentou influência na resistência mecânica dos corpos-de-prova. / The crystallization of salts is an important and frequently observed pathology in masonry. However, it is still one of the least understood pathologies. The aim of this study is to evaluate the impact of florescence of soluble salts in ceramic blocks developed with phosphate sludge. For this purpose, blocks were molded with 0, 2.5% and 5% of phosphate sludge, which were sintered at temperatures of 750°C, 850°C, 950°C and 1050 ° C. The blocks were divided into two groups, one of which was kept under controlled temperature and humidity and the other was subjected to wetting and drying cycles. The groups were tested at 1, 30, 110 and 180 days. They were subjected to image analysis (binocular magnifying glass, graphic software and scanning electron microscopy), capillary water absorption, mercury intrusion porosimetry and flexural strength. The methods, x-ray diffraction, x-ray fluorescence and emission spectrometry, were used to investigate the phase and chemical composition. The results indicate the presence of aluminum, silicon, calcium, potassium, sulfur, iron and manganese, among which stands out the combination of sulfur and calcium. Thus, the gypsite is considered to be likely responsible for the soluble salts, whose deposits were found in varying extent and intensity, prevailing in the blocks with addition of waste. The variation in porosity and the apparent decrease in the coefficient of capillary absorption along the tests may be associated with the processes of solubilization and recrystallization. In cycling time studied, the phenomenon did not influence the mechanical strength of specimens.
29

Avaliação da suscetibilidade da alvenaria estrutural a danos por exposição a altas temperaturas com medidas de controle da dilatação

Menegon, Julia January 2017 (has links)
A alvenaria estrutural é um dos mais antigos sistemas construtivos existentes. Atualmente estruturas em alvenaria encontram uma vasta aplicação em construções residenciais, sobretudo em obras de interesse social. No entanto, ao contrário das estruturas de concreto, cujo comportamento durante exposição ao fogo e sua resistência residual tem estudos e resultados amplamente disseminados, pouco se sabe a respeito do comportamento de estruturas de alvenaria submetidas à ocorrência de sinistros dessa natureza. Com a intensificação das preocupações acerca da segurança das edificações e de seus usuários em situações de incêndio, faz-se cada vez mais imprescindível o conhecimento do comportamento dos sistemas empregados atualmente na construção civil perante a ação de altas temperaturas. Tendo isso em vista, o presente trabalho teve por objetivo a realização de uma análise dos danos e do comportamento apresentados por amostras de alvenaria com função estrutural ao serem expostas ao aquecimento excessivo. Foram avaliadas nesse estudo paredes de pequenas dimensões executadas com blocos estruturais cerâmicos. Visando simular condições mais próximas da realidade, foram restringidas, com o auxílio de macacos hidráulicos, as laterais das amostras, para que houvesse contenção da dilatação das mesmas. Com o intuito de verificar diferentes tipologias de alvenarias, foram utilizados três blocos distintos: de 14 cm de largura, com resistências de 7 e 10 MPa, e de 19 cm de largura, com 7 MPa de resistência à compressão. Também foram variadas as espessuras das juntas entre as unidades e a argamassa de assentamento das mesmas, a fim de compreender a importância desses fatores para o comportamento das amostras, e, por fim, foram ensaiadas amostras com revestimento na face exposta As miniparedes foram acopladas a um forno de resistências elétricas e submetidas a um aquecimento próximo à curva padrão determinada por norma, até a temperatura máxima de 950ºC, a qual foi mantida pelo período de 4 horas. Foram mensurados, além da temperatura dentro do forno, no interior da parede e na superfície das amostras, os deslocamentos transversais ocorridos durante o ensaio. Também se utilizaram transdutores de deslocamento para verificar a dilatação dos blocos e o esmagamento ou abertura das juntas. Imagens termográficas da face oposta ao aquecimento foram capturadas no decorrer da exposição. Ao final das análises, pôde-se inferir que as miniparedes ensaiadas apresentaram bom desempenho frente à ação das altas temperaturas, mantendo sua estanqueidade, isolamento térmico e resistência mecânica. A restrição lateral não ocasionou desplacamentos dos blocos, no entanto, pôde-se observar transferência de tensão para os mesmos quando utilizadas nas juntas argamassas pouco flexíveis. O deslocamento transversal apresentado pelas amostras indicou deflexão em direção ao forno durante o aquecimento, com posterior reversão do sentido. Tal deflexão foi atenuada pela redução da espessura das juntas, pelo uso de argamassas menos flexíveis e pelo aumento da resistência e largura dos blocos. As alvenarias de 19 cm de largura e, especialmente, as dotadas de revestimento apresentaram melhor desempenho térmico que as demais. / Structural masonry is one of the oldest existing building systems. Nowadays, masonry structures find a wide application in residential constructions, mainly in those with social interest. However, unlike concrete structures, whose behavior during fire exposure and its residual resistance have widely disseminated studies and results, there is a lack of knowledge about the behavior of masonry structures submitted to fire. Because of the spread of concerns about the safety of buildings and their users in fire situations, it becomes essential to know the behavior of the systems currently used in civil construction when exposed to high temperatures. With this in view, the present study intended to analyze the damage and the behavior of structural masonry samples exposed to heating. This study evaluated clay hollow-bricks small walls, and, in order to simulate real conditions, the boundaries of the samples were restrained, with the aid of hydraulic jacks, aiming to restrain the deformation. In order to verify different types of masonry, three different blocks were used: 14 cm wide, with nominal strength of 7 and 10 MPa, and 19 cm wide, with 7 MPa of compressive strength. The thicknesses of the joints and the mortar were also varied, in order to understand the importance of these factors in the behavior of the samples, and, finally, samples were tested with a mono-layer coating at the exposed face. The small walls were coupled to an electrical furnace and subjected to a heating approximately equal to the standard curve, up to the maximum temperature of 950ºC, which was maintained for 4 hours The deflections of the samples during the test were measured, beyond the temperature inside the furnace, in the center of wall and at the non-exposed surface. Clip gages were also used to verify the expansion of the blocks and the crushing or opening of the mortar joints. Thermographic images of the opposite face were captured during the testing. At the end of this research, it was possible to affirm that the walls had good behavior against the high temperatures, maintaining their integrity, thermal insulation and load-bearing capacity. The restriction of the boundaries did not cause the spalling of the blocks, however, it was possible to observe the stress transfer to them in samples with rigid joint mortar. The deflection of the samples increases towards the furnace during the heating, and, then, they show the phenomenon of “reverse bowing”, changing the direction of the displacements. Reducing the thickness and increasing the stiffness of the joint mortars, as well as the increase in block strength and width attenuated such deflection. The masonry 19 cm width and, specially, the ones with coating shows better thermal performance, comparing to the others.
30

ESTUDO DO COMPORTAMENTO MECÂNICO DE VERGAS ARMADAS COM TRELIÇAS PLANAS EM ALVENARIA ESTRUTURAL / ANALYSIS OF MECHANICAL BEHAVIOR OF LINTELS REINFORCED WITH PLANE TRUSS IN STRUCTUTURAL MASONRY

Rezende, Fabiana Martins de 31 August 2012 (has links)
The main goal of these studies were evaluate the mechanical behavior of structural masonry lintels built with hollow clay blocks. The compressive strength and failure mode of lintels under bending were determine using three different types of lintels: grouted and reinforced lintels made with U section blocks, structural blocks with horizontal prefabricated bedding joint reinforcements and horizontal and vertical joint reinforcements with MURFOR® steel reinforcement and stirrups. The test results indicated that the failures occur by shear strength. The use of lintels with grout demonstrated high levels of loading resistance, when compared with the others models. The use of horizontal and vertical reinforcement (MURFOR®), support higher level of loading, when it was compared with only horizontal joint reinforce. / O presente trabalho trata da análise experimental de vergas em paredes de alvenaria estrutural, executadas com blocos cerâmicos vazados, cujo objetivo principal é avaliar o comportamento mecânico e modos de ruptura, após aplicação de forças concentradas no terço médio do elemento. O programa experimental consistiu na confecção de vergas grauteadas e com armadura para flexão, utilizando-se blocos do tipo canaleta em U , e de vergas formadas por blocos estruturais e juntas de argamassa armadas, mediante o uso de treliças planas tipo MURFOR® e de estribos. Os resultados dos ensaios indicaram que as rupturas ocorreram pela ação de força cortante, verificando-se, pelo modo de ruptura, esmagamento localizado na parte superior de alguns blocos. Os modelos grauteados resistiram a níveis de cargas aplicadas maiores, comparados aos demais testados. Os modelos constituídos por blocos e armados nas juntas verticais e horizontais de argamassa, suportaram intensidades maiores de força que os modelos reforçados somente nas juntas horizontais, comprovando o aumento na resistência à força cortante dos elementos testados.

Page generated in 0.0761 seconds